Autoranging Digital Clampmeters - 600A DC / AC

36-AUTO 3690Auto Accessories

600A DC / AC Auto/Manual, 3¾ Digit, 4,000 Counts, K Type Bead Probe (upto 2600C)
Auto Ranging, 3¾ Digit, 4,000 Counts, 600A DC/AC, Frequency, Data Hold, Audible Model : TPK-B
Temperature, Capcitance, Data Hold, Continuity, Diode Test, D Zero Button
Hz/Duty, NCV, APO (for DCA), APO
Ranges Ranges
AC Current 40A, 400A/600A AC Current 400A, 600A
Accuracy ±(2.5%rdg+8dgt) on 40A Accuracy ±(1.75%rdg + 5dgt)
±(2.5%rdg+5dgt) on 400A/600A (50~60Hz)
Overload 600A AC max. for 1 min. Overload 600A AC max. for 1 min. K Type Stick Probe (upto 5000C)
DC Current 40A, 400A/600A Model : TP-02
AC Voltage 4V, 40V, 400V, 600V
Accuracy ±(3%rdg+3dgt)
Accuracy ±(1.2%rdg + 4dgt)
Overload 600A DC max. for 1 min.
AC Voltage 4V, 40V,400V, 600V (Auto Ranging) (50~60Hz)
±(4%rdg + 5dgt) for 600V
Accuracy ±(1.2%rdg+3dgt)
DC Voltage 400mV, 4V, 40V, 400V, 600V DC Current 400A, 600A
(Auto Ranging) Accuracy ±(1.5%rdg + 5dgt) for 400A
Accuracy ±(0.8%rdg+3dgt) ±(2%rdg + 5dgt) for 600A
Temperature -200C to 7500C Overload 600A DC max. for 1 min.
Accuracy ±(3%rdg+5dgt) DC Voltage 400mV, 4V, 40V, 400V, 600V
Capacitance 40nF, 400nF, 4µF, 40µF,200µF Accuracy ±(0.5%rdg + 8dgt)
(Auto Ranging) (400mV to 400V) Pair of Test Leads suitable for DMM/DTT
Accuracy ±(3%rdg+2dgt) ±(0.7%rdg + 2dgt) for 600V Model :
±(5%rdg+8dgt) for 200µF TL-DMM/DTT
Resistance 400V, 4kV, 40kV, 400kV,
Frequency 10Hz, 100Hz, 1000Hz,
4MV, 40MV
10KHz, 100KHz, 1000KHz,
10MHz (Auto Ranging) Accuracy ±(0.75%rdg + 8dgt)
Accuracy ±(0.5%rdg+2dgt) 400V to 400kV
Duty Cycle 0.1% - 99.9% ±(1%rdg + 6dgt) 4MV
Accuracy Reference only ±(2%rdg + 4dgt) 40MV
Resistance 400V, 4kV, 40KV, 400kV, Overload 600V DC / AC rms.
4MV, 40MV (Auto Ranging) Frequency 100Hz, 1KHz, 10KHz,
Accuracy ±(1%rdg+3dgt) 100KHz, 500KHz
Audible 30V Approx Accuracy ±(0.3%rdg + 2dgt)
Continuity Duty Cycle 1% to 90 %
Diode Test 1.0 ±0.6mA Approx Pair of Test Leads suitable for Insulation
Power Two 1.5V ‘AAA’ Battery
Function Tester
Power Two 1.5V 'AAA' Battery Battery Life 150 hours (typical)
Model : TL-IT
Battery Life 200 Hours Typical Low Battery " + _ " is Indicated
Low Battery “ + _ ” is indicated Over Range "OL" or "-OL" is indicated
Dimension 185 x 65 x 28 mm (approx.) Dimensions 220 x 85 x 46 mm (approx.)
Weight 170gms Including Battery (approx.) Weight 280gms Including Battery
Accessories One Pair of Test Leads, (approx.)
Instruction Manual, Carrying
Case, Battery (installed) Jaw Opening Cable Dia. 30mm max.
K Type Thermocouple (upto2600C) Accessories Supplied with a Pair of Test
Jaw Opening Cable Dia. 25mm (max.) Leads, Battery (installed), Instr.
Safety Standard CAT II 600V Manual & Carrying Case

ISO 9001-2015 Certified Company 86 www.mecoinst.com