ENGINEERS
Audiometric Booths
H.S. Engineers
Tel: 0120-4327253
M: +91-9810006942
Tele-Fax: 0120-4327052
H.S. Engineers
Tel: 0120-4327253
M: +91-9810006942
Tele-Fax: 0120-4327052
2 CONSTRUCTION
HSE 100mm (4”) thick Acoustic panels - plain galvanised / CRCA steel
exterior surfaces and perforated galvanised steel interior surfaces.
3 DOOR
One 604mm wide x 1680 mm high (clear opening) Noise-Lock door. For
complete safety and effective acoustic control, self-aligning magnetic
compression seals are mounted on the top, bottom and sides of the door
leaf.
4 WINDOW
One double glazed unit comprises 6mm thick safety glass fitted in
aluminium frames; clear view 750mm high x 600mm wide. The lower
portion of the window has a frosted section.
8 ELECTRICAL
A 3000mm long drop cord with fitted 12 amp plug is provided for
connection to a 220/240v mains power point.
OPTIONAL EXTRAS (Additional costs apply)
12 NOISE REDUCTION
Noise reduction here is defined as the measured difference between the
sound pressure levels in a reverberant room, outside the booth and
inside the booth.
13 INSTALLATION
Booth is supplied pre-assembled, finish decorated and ready for use.
Also available in kit form where access is difficult for an assembled
unit.
14 PAINT FINISH
Off-White polyester powder paint, RAL 9002 matt. Exterior and
interior.
H.S. Engineers
15 OPTIONAL EQUIPMENT
(Additional costs apply) Tel: 0120-4327253
(a) Vibration Isolators
(b) Alternative wired jack panels M: +91-9810006942
(c) Alternative paint colors Tele-Fax: 0120-4327052
Noise Reduction: The minimum allowable noise reduction of completely assembled rooms,
shown in the table below.
Sound Absorption: The composite sheet metal and sound absorbing assembly shall have a
minimum overall noise reduction coefficient of 0.9 (1.10) as shown in the table below.
Noise 33 31 39 50 57 61 68 62 NIC 51
Reduction,
dB
Sound 0.38 0.94 1.19 1.11 1.06 1.03 1.03 1.04 NRC
Absorption 0.95
Coefficient