Audiometric Booths

H.S. Engineers
Tel: 0120-4327253
M: +91-9810006942
Tele-Fax: 0120-4327052

A-70 A, Sec-10, Noida-201301


UP, India
Audiometric Booths

• Single wall construction


• 100mm thick Acoustic Modular Panels
• Structurally isolated
• Equipped with ventilation, lighting and jack panel
• Fast, clean installation
• Wide range of sizes and configurations available
• BS EN ISO 9001 quality
• Excellent value for money
AUDIOMETRIC ROOMS
IN T R O D U C T I O N

•HSE best selling booth


•Complies fully with BS EN ISO 26189
•Available from stock
•Supplied fully assembled or in ‘kit’ form
•Fitted with castors for complete
mobility
•Left hand or right hand door option
•BS EN ISO 9001/14001 quality registered
•Maintenance free LED lighting

The HSE Audiometric Booth provides


a controlled acoustic environment in
which hearing screening can be
undertaken efficiently at low cost,
whilst complying fully with BS EN ISO
26189. Its compact design allows it to
pass easily through any standard
doorway and fitted castors make it
completely mobile. Equipped with its
own ventilation system, lighting, seat,
shelf and jack panel (for connection
to an audiometer) it is ready to use
within minutes of delivery.

H.S. Engineers
Tel: 0120-4327253
M: +91-9810006942
Tele-Fax: 0120-4327052

A-70 A, Sec-10, Noida-201301


UP, India
ACOUSTIC AND STRUCTURAL SPECIFICATION
1 DIMENSIONS
Our Audiometric Standard Outside dimensions are: 1200 mm wide x
1200 mm deep x 2450 mm high (includes castors, but excludes shelf).
Inside Dimensions: 1000 mm wide x 1000 mm deep x 2150 0mm high.
Weight: 295kg net, 322kg shipping weight. Customized Audiometric
Booth are also available

2 CONSTRUCTION
HSE 100mm (4”) thick Acoustic panels - plain galvanised / CRCA steel
exterior surfaces and perforated galvanised steel interior surfaces.

3 DOOR
One 604mm wide x 1680 mm high (clear opening) Noise-Lock door. For
complete safety and effective acoustic control, self-aligning magnetic
compression seals are mounted on the top, bottom and sides of the door
leaf.

4 WINDOW
One double glazed unit comprises 6mm thick safety glass fitted in
aluminium frames; clear view 750mm high x 600mm wide. The lower
portion of the window has a frosted section.

5 JACK PANEL ROOF & WALL CONSTRUCTION –


Completely pre-wired, flush-mounted jack panel consists of nine 6mm
3pole sockets. Roofs and walls shall be constructed from
standard medical acoustic panels, 100mm thick.
6 VENTILATION Outer panel faces shall be1.6mm steel sheet while
Ceiling panel contains an Noiseless all-in-one silenced forced ventilation inner faces will be 0.7mm galvanized perforated
system. steel sheet with 2.5mm diameter openings on
5.0mm staggered centers. Panels are reinforced
and framed with 1.2mm channels. Average weight
7 LIGHTING to be not less than 50kg/m2.
LED maintenance free, ceiling recessed light.

8 ELECTRICAL
A 3000mm long drop cord with fitted 12 amp plug is provided for
connection to a 220/240v mains power point.
OPTIONAL EXTRAS (Additional costs apply)

9 SHELF (external) Acoustic double glazed vision panel within door


Folding shelf for audiometer, 680mm long x 450mm deep. (Optional) (150mm x 600mm high).
Emergency light pack.
10 SEAT (internal) Internal power sockets..
Fixed moulded bench seat, 450mm deep, colour black. (Optional) Fabric covering to internal walls.
Increased clear opening width doors (where
11 FLOOR possible).
Foam-backed carpet. One-way viewing film fitted to window.

12 NOISE REDUCTION
Noise reduction here is defined as the measured difference between the
sound pressure levels in a reverberant room, outside the booth and
inside the booth.

13 INSTALLATION
Booth is supplied pre-assembled, finish decorated and ready for use.
Also available in kit form where access is difficult for an assembled
unit.

14 PAINT FINISH
Off-White polyester powder paint, RAL 9002 matt. Exterior and
interior.
H.S. Engineers
15 OPTIONAL EQUIPMENT
(Additional costs apply) Tel: 0120-4327253
(a) Vibration Isolators
(b) Alternative wired jack panels M: +91-9810006942
(c) Alternative paint colors Tele-Fax: 0120-4327052

A-70 A, Sec-10, Noida-201301


UP, India
www.hsengineers.in
AUDIOMETRIC BOOTHS PROVIDE A SUITABLE ENVIRONMENT FOR
HEARING TESTING, EXAMINATION AND RESEARCH

The HSE Audiology booths are constructed


from 100 mm thick acoustic modular
panels and offer a fitting environment for
a whole range of audiological
investigations and measurements
including bone conduction tests, speech
therapy and psychological tests.

NOISE REDUCTION AND SOUND ABSORPTION

Noise Reduction: The minimum allowable noise reduction of completely assembled rooms,
shown in the table below.

Sound Absorption: The composite sheet metal and sound absorbing assembly shall have a
minimum overall noise reduction coefficient of 0.9 (1.10) as shown in the table below.

Octave Band Frequencies


63 125 250 500 1K 2K 4K 8K

Noise 33 31 39 50 57 61 68 62 NIC 51
Reduction,
dB

Sound 0.38 0.94 1.19 1.11 1.06 1.03 1.03 1.04 NRC
Absorption 0.95
Coefficient

Noise-reduction measurements shall be made


in accordance with the following ASTM
designations:

E596 and, where applicable, portions of E90


and E336.

NIC – Noise Isolation Class, single number H.S. Engineers


rating system for noise-reduction
characteristics. Tel: 0120-4327253
M: +91-9810006942
Tele-Fax: 0120-4327052

A-70 A, Sec-10, Noida-201301


UP, India

You might also like