You are on page 1of 7

General Purpose

MA12-150 (12V150AH)
Specification
Nominal Voltage 12V
Nominal C apa city(10 HR ) 150.0AH
Length 485 3mm (19.09 inches )
W idth 170 2mm (6.69 inches )
Dimens ion
C ontainer Height 240 2mm (9.45 inches )
Total Height (with Terminal) 240 2mm (9.45 inches )
Approx Weight Approx 42.5 kg (93.7lbs )
Terminal T11
Container Ma terial ABS
156.0 A H/7.80A (20hr ,1.80V/cell,25 0
C/77 0 F)
150.0 A H/15.0A Applications
0 0
(10hr,1.80V/cell,25 C/77 F)
0
Rated Cap acity 130.5 A H/26.1A (5hr,1.75V/cell,25 C/77 0 F)
115.2 A H/38.4A (3hr,1.75V/cell,25 0
C/77 0 F) All purpose
93.9 A H/93.9A (1hr,1.60V/cell,25 0
C/77 0 F) Uninterruptable Power Supply (UPS)
Ma x. Dis charge C urrent 1500A (5s) Electric Power System (EPS)
Internal Re sistance Approx 3.5m Ù Emergency backup power supply
Discharge : -15 0
50 C (5 122 F) 0
Emergency light
Ope rating Temp.Ra nge Charge : 0 40 0C (32 104 0F) Railway signal
Storage : -15 40 0C (5 104 0 F)
Aircraft signal
Nominal O perating Temp. R ange 25 3 0C (77 50 F ) Alarm and security system
Initial C harging C urrent les s than 4 5.0A.Voltage Electronic apparatus and equipment
C ycle U s e
14.4V ~15.0V a t 2 5 0 C (77 0 F )Temp. C oefficient -30mV /0C
Communication power supply
No limit on I nitial C harging C urrent V oltage DC power supply
S tandby U s e
13.5 V ~13.8 V a t 2 5 0 C (77 0 F )Temp. C oefficient -20mV /0C Auto control system
o o
40 C (104 F ) 103%
C apacity a ffected by
25 o C ( 77 o F ) 100%
Temperature V dS
0o C ( 32 o F ) 86%
Le och LP se ries b atteries may be sto red for up to 6 months
Self Discharge at 25 0 C(7 7 0F) and then a fre she ning c harge is re quired.
9
t est ed
Fo r higher temperatures t he time interva l will be s horter. G e rma ny

0 0
Co ns ta nt C ur re nt D is ch ar ge (A m pe re s) a t 2 5 C (7 7 F )
F.V/ Tim e 5m in 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10 h 20 h
1.8 5V /ce ll 259.2 211.5 185.4 156.6 118.5 90.2 74.3 46.5 35.1 28.8 24.4 21.3 17.1 14.4 7.69
1.8 0V /ce ll 311.4 243.0 205.8 171.9 129.9 97.4 79.2 49.2 37.6 30.4 25.6 22.3 17.8 15.0 7.80
1.7 5V /ce ll 365.4 267.3 223.2 184.5 137.7 102.4 83.1 51.0 38.4 31.0 26.1 22.7 18.1 15.2 7.94
1.7 0V /ce ll 401.4 291.6 238.8 198.9 146.7 107.4 86.7 53.0 39.7 31.8 26.6 23.1 18.4 15.3 8.01
1.6 5V /ce ll 435.6 315.0 254.4 210.6 154.2 112.2 90.0 54.5 40.7 32.6 27.2 23.5 18.6 15.5 8.09
1.6 0V /ce ll 477.0 339.3 269.4 223.2 162.3 117.6 93.9 56.3 41.7 33.3 27.7 23.9 18.9 15.7 8.18

Co ns ta nt P ow er D is ch ar ge (W at ts ) a t 2 5 0 C (7 7 0 F )
F.V/ Tim e 5m in 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10 h 20 h
1.8 5V /ce ll 473.9 390.7 346.0 295.2 225.9 173.4 143.2 90.3 68.3 56.3 47.9 41.8 33.7 28.5 15.2
1.8 0V /ce ll 563.3 443.6 378.9 319.3 243.8 185.8 152.0 94.8 72.8 59.1 49.9 43.6 35.1 29.6 15.4
1.7 5V /ce ll 646.9 480.1 405.8 339.4 256.3 193.4 158.7 98.0 74.0 60.1 50.9 44.2 35.5 29.9 15.7
1.7 0V /ce ll 690.9 511.9 428.2 363.1 271.5 202.1 165.1 101.7 76.4 61.4 51.7 44.9 36.0 30.2 15.8
1.6 5V /ce ll 739.2 547.9 452.6 381.6 283.1 209.3 170.1 103.9 78.0 62.8 52.6 45.6 36.5 30.5 16.0
1.6 0V /ce ll 790.7 576.7 471.4 400.0 295.9 218.1 176.5 106.9 79.6 64.0 53.4 46.3 36.8 30.8 16.1

1
General Purpose
MA12-150 (12V150AH)
Specification
Nominal Voltage 12V
Nominal C apa city(10 HR ) 150.0AH
Length 485 3mm (19.09 inches )
W idth 170 2mm (6.69 inches )
Dimens ion
C ontainer Height 240 2mm (9.45 inches )
Total Height (with Terminal) 240 2mm (9.45 inches )
Approx Weight Approx 42.5 kg (93.7lbs )
Terminal T11
Container Ma terial ABS
156.0 A H/7.80A (20hr ,1.80V/cell,25 0
C/77 0 F)
150.0 A H/15.0A Applications
0 0
(10hr,1.80V/cell,25 C/77 F)
0
Rated Cap acity 130.5 A H/26.1A (5hr,1.75V/cell,25 C/77 0 F)
115.2 A H/38.4A (3hr,1.75V/cell,25 0
C/77 0 F) All purpose
93.9 A H/93.9A (1hr,1.60V/cell,25 0
C/77 0 F) Uninterruptable Power Supply (UPS)
Ma x. Dis charge C urrent 1500A (5s) Electric Power System (EPS)
Internal Re sistance Approx 3.5m Ù Emergency backup power supply
Discharge : -15 0
50 C (5 122 F) 0
Emergency light
Ope rating Temp.Ra nge Charge : 0 40 0C (32 104 0F) Railway signal
Storage : -15 40 0C (5 104 0 F)
Aircraft signal
Nominal O perating Temp. R ange 25 3 0C (77 50 F ) Alarm and security system
Initial C harging C urrent les s than 4 5.0A.Voltage Electronic apparatus and equipment
C ycle U s e
14.4V ~15.0V a t 2 5 0 C (77 0 F )Temp. C oefficient -30mV /0C
Communication power supply
No limit on I nitial C harging C urrent V oltage DC power supply
S tandby U s e
13.5 V ~13.8 V a t 2 5 0 C (77 0 F )Temp. C oefficient -20mV /0C Auto control system
o o
40 C (104 F ) 103%
C apacity a ffected by
25 o C ( 77 o F ) 100%
Temperature V dS
0o C ( 32 o F ) 86%
Le och LP se ries b atteries may be sto red for up to 6 months
Self Discharge at 25 0 C(7 7 0F) and then a fre she ning c harge is re quired.
9
t est ed
Fo r higher temperatures t he time interva l will be s horter. G e rma ny

0 0
Co ns ta nt C ur re nt D is ch ar ge (A m pe re s) a t 2 5 C (7 7 F )
F.V/ Tim e 5m in 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10 h 20 h
1.8 5V /ce ll 259.2 211.5 185.4 156.6 118.5 90.2 74.3 46.5 35.1 28.8 24.4 21.3 17.1 14.4 7.69
1.8 0V /ce ll 311.4 243.0 205.8 171.9 129.9 97.4 79.2 49.2 37.6 30.4 25.6 22.3 17.8 15.0 7.80
1.7 5V /ce ll 365.4 267.3 223.2 184.5 137.7 102.4 83.1 51.0 38.4 31.0 26.1 22.7 18.1 15.2 7.94
1.7 0V /ce ll 401.4 291.6 238.8 198.9 146.7 107.4 86.7 53.0 39.7 31.8 26.6 23.1 18.4 15.3 8.01
1.6 5V /ce ll 435.6 315.0 254.4 210.6 154.2 112.2 90.0 54.5 40.7 32.6 27.2 23.5 18.6 15.5 8.09
1.6 0V /ce ll 477.0 339.3 269.4 223.2 162.3 117.6 93.9 56.3 41.7 33.3 27.7 23.9 18.9 15.7 8.18

Co ns ta nt P ow er D is ch ar ge (W at ts ) a t 2 5 0 C (7 7 0 F )
F.V/ Tim e 5m in 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10 h 20 h
1.8 5V /ce ll 473.9 390.7 346.0 295.2 225.9 173.4 143.2 90.3 68.3 56.3 47.9 41.8 33.7 28.5 15.2
1.8 0V /ce ll 563.3 443.6 378.9 319.3 243.8 185.8 152.0 94.8 72.8 59.1 49.9 43.6 35.1 29.6 15.4
1.7 5V /ce ll 646.9 480.1 405.8 339.4 256.3 193.4 158.7 98.0 74.0 60.1 50.9 44.2 35.5 29.9 15.7
1.7 0V /ce ll 690.9 511.9 428.2 363.1 271.5 202.1 165.1 101.7 76.4 61.4 51.7 44.9 36.0 30.2 15.8
1.6 5V /ce ll 739.2 547.9 452.6 381.6 283.1 209.3 170.1 103.9 78.0 62.8 52.6 45.6 36.5 30.5 16.0
1.6 0V /ce ll 790.7 576.7 471.4 400.0 295.9 218.1 176.5 106.9 79.6 64.0 53.4 46.3 36.8 30.8 16.1

1
D im en si o n s

T1 1 T er m in al
Unit: mm [inch es]
20 [0.78 7]

140 2
170 2
M8 [0.315 ]
7 [0. 276]

2
2
MA12-150(12V 150A H)
M a i n te n a n c e - f r e e S e a l e d L e a d - a c i d B a tte r y
Wa rning:

240
225
_
R is k of fire, ex plos ion, or burns . Do not dis a s s emble,
O
h e a t a b o v e th e 5 0 C , o r i n c i n e r a te .

R
MH 26866
+
Dimens ions (mm)
P b.
L E OC H B AT T E R Y C O.,LT D. Non-s pillable
MA DE IN C HINA B AT T E R Y MUS T B E R E C Y C L E D

389 2
450 2 485 3

Discharge Characteristics Float Charging Characteristics


12V
Battery
V Tem pe ra ture:2 5 0 C( 77F)
0
C harge C harging C harging
Volume C urrent Voltage
13.0 0
(V ) 0.10 CA- 2.25 V/ce ll te mperature25 C
% (X C A)

12.0
0.2 5
120 15.0
110 C harged V olume
11.0
Terminal Voltage(V)

0.2 0
100
0.1C 0.0525C 14.0
0.205C 90 C harg e V oltage
10.0 0.4C 80 (C ons tant 2.2 5v/cell)
0.1 5
70 13.0
1C 0.6C
9.0 60
A fter 50% D is c harg e
50 0.1 0
12.0
40 A fter 100% D is c harg e
8.0 30
2C 0.0 5 11.0
20
10 C harg in g C urr ent
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20
0 0
M in H
0 4 8 12 16 20 24 28 32 36 40
Dis charge T ime Cha rging Tim e(h ours)

Tem pe ra tu re E ffe ct s in R el at io n to B at tery C ap ac ity E ff ec t o f T em per at u re o n L o n g T er m F lo at L if e

120 10
0.1 CA 8
100 0.1 7C A 6
5
0.2 5C A 4
Chargi ng voltage :
%

80 2.25V/ cell
3
Life expectancy(year)
C a pa c ity

60 2

40
1

20
0.5
20 30 40 50 0
C
-20 -10 0 10 20 30 40 50 60 68 86 104 122 O
F
0 Batter y temp eratur e
Temper ature( C)

Cyc le Life in Rel atio n to Dep th of Dis cha rge Self Discharge Characteristics
Te st ing c ondition
100
D is ch ar ging:c urre nt 0. 17 C (F V 1. 7V /cel l);
C ha rging: cu rren t 0.2 5C m ax , v olta ge 2 .4 5V /cel l; 10 C
0 A
C ha rging v olume: 12 5% o f dis ch ar ge d c ap ac ity. 80
0
25 C
R emaining C apacity(%)

12 0 60
B
0
40 0 C 30 C
10 0 40

80 C
20
C a pc ity(% )

60
10 0% 50 % 30 % 0
DO D DO D DO D 2 4 6 8 10 12
40
Ambient Termperature: S torage Time(Months )
25 oC ( 77 oF)
20 No sup plemen tary cha rge req uired
A (Carry o ut supp lementa ry charg e before use if 1 00% cap acity is require d.)
0 Supplem entary c harge re quired b efore us e.Optio nal cha rging w ay as b elow:
0 20 0 40 0 60 0 80 0 1 00 0 1 20 0 1.Charg ed for a bove 3 days at limted current 0.25CA and co nstant v olatge 2 .25V/ce ll.
B 2.Charg ed for a bove 20 hours a t limted current 0.25CA and co nstant v olatge 2 .45V/cel l.
Nu mber o f C yc les 3.Charg ed for 8 ~10hou rs at lim ted curr ent 0.05 CA .

Supplem entary c harge m ay often fail to r ecover the cap acity .


C The bat tery sho uld nev er be left standin g till thi s is rea ched.

Sales Office

Importado Por: COÉXITO S.A.


Carrera. 5 No. 61A - 95 / Cali - Colombia
Línea nacional de atención al cliente: 01 8000 510606
www.coexito.com.co

2
Product detail parameters
To avoid harm to you and others, here are
MODEL BEP150S BEP300A BEP500SA BEP600S BEP800S
some of the following security considerations.
Rated Power 150W 300W 500W 600W 800W
WARNING Be sure to follow the meanings of the various
Peak Power 300W 600W 1000W 1200W 1600W
Output flags. See the following.
Frequency

WaveForm
Power Inverter
Battery
Voltage
12V / 24V
(Optional) 12V / 24V / 48V(Optional) Inammable gas
●When connected to a battery, sparks are produced. Make sure there is no ammable Solar Power Generation System
Voltage gas before connecting.
Range 10-15V(12V) / 20-30V(24V) / 40-60V(48V)
●The battery will produce ammable gas when charging and discharging. It should be
Input
No load 0.6A(12V) 0.8A(12V) 0.8A(12V) 0.6A(12V) 0.8A(12V) well ventilated and should not be stored in other places where it is ammable BEP150S / BEP300A / BEP500SA
0.6A(24V) 0.6A(24V) 0.6A(24V)
Current 0.3A(24V)
0.3A(48V) 0.3A(48V)
0.3A(24V)
0.3A(48V) No parallel with city power BEP600S / BEP800S / BEP1000S
The output can not be paralleled with the power supply, it will damage the inverter and
Efficiency ≥90% cause the danger of electric shock。 BEP1500S / BEP2000S
Low Voltage Alarm 11(12V) / 21V(24V) / 42V(48V) BEP3000S / BEP5000S
Battery low Minors are prohibited from using them
Battery voltage protection 10V±0.5V(12V) / 20V±0.5V21V(24V) / 40V±0.5V(48V)
input
protection Battery high
voltage protection
Battery reverse
15V±0.5V(12V) / 30V±0.5V21V(24V) / 60V±0.5V(48V)
Can not be used by minors, inverter output is high voltage, may lead to electric shock
risk。
Pure Sine Wave
NO YES YES YES NO No disassembly or assembly

Inverter Manual
polarity protection
Do not disassemble or modify the inverter without permission. Unauthorized removal
Other protection High temperature protection、Shortcircuit Protection、Overload Protection or modication of the inverter may result in a safety accident such as a malfunction,
re or electric shock。
USB 5V / 500mA
FAN Smart fan,Automatic startup of high temperature and load Bar contacts are prohibited
Do not place bars or other metal objects at the opening or socket of the inverter. This
Operating Temperature 0℃~40℃@100%load, Humidity 20%~90%RH,No refrigeration may touch the internal parts and cause electric shock and inverter damage
environment
S ize ( mm ) 160*95*55 172*150*58 260*150*78 262*150*76 309*180*172
Wet hands, do not touch
W eight ( g ) 530 910 1700 1800 3050 Do not touch the body and plug with wet hands, which may cause electric shock and
personal safety

MODEL BEP1000S BEP1500S BEP2000S BEP3000S BEP5000S Keep away from re and high temperatures
Fire and explosion can occur in inverter and battery when running in ame and high
Rated Power 1000W 1500W 2000W 3000W 5000W temperature region。

Peak Power 2000W 3000W 4000W 6000W 10000W


Output
Frequency 50Hz / 60Hz(Optional) No throwing
Bumping the inverter can cause damage and other safety hazards.
WaveForm Pure Sine Wave
Battery 12V / 24V
Voltage 12V / 24V / 48V(Optional) (Optional)
Voltage Medical equipment disabled
Range 10-15V(12V) / 20-30V(24V) / 40-60V(48V) This inverter has not been tested and can not be used in medical equipment
Input 0.8A(12V) 1.8A(12V) 3.0A(12V) 3.8A(12V) 2.5A(24V)
No load
0.6A(24V) 1.0A(24V) 1.5A(24V) 2.0A(24V) 1.4A(48V)
Current Please connect the ground wire.
0.3A(48V) 0.5A(48V) 0.8A(48V) 1.2A(48V)
In order to ensure the safety of use, please connect the ground wire.
Efficiency ≥90%
Low Voltage Alarm 11(12V) / 21V(24V) / 42V(48V)
Battery low
Battery voltage protection 10V±0.5V(12V) / 20V±0.5V(24V) / 40V±0.5V(48V)
input
protection Battery high
voltage protection 15V±0.5V(12V) / 30V±0.5V(24V) / 60V±0.5V(48V)
Battery reverse To ensure reliable ser vice, the inverter must be used properly.
polarity protection NO
Please read the instruction manual before use. Par ticular
Other protection High temperature protection、Shortcircuit Protection、Overload Protection Moisture proof and waterproof Please insert completely
Please pay attention to moisture proof Please insert the load device plug into attention should be paid to the warning and attention of this
USB 5V / 500mA and waterproof. The inverter may cause the inverter socket completely. If the
short circuit, re and electric shock due plug is fully inserted at the end, it may brochure. Caution for certain conditions and practices that may
FAN Smart fan,Automatic startup of high temperature and load to humidity or water inow。 lead to electric shock and overheating, cause damage to the inverter. Make clear warning statements
Operating Temperature 0℃~40℃@100%load, Humidity 20%~90%RH,No refrigeration and even cause a re accident. Do not
environment use damaged plugs, power outlets, about certain conditions and practices that may cause bodily
S ize ( mm ) 367*150*76 452*150*142 454*180*142 529*180*142 585*180*167 electrical wires。
harm. Please read all instructions before using the inverter. 1
W eight ( g ) 2750 4000 4900 6020 8000
Product characteristics Please read this instruction manual carefully so that it can be
Remarks:Please select the corresponding parameters according to the ●The inverter is equipped with perfect protection circuit. Provide safe used correctly. Remember to read the "safety precautions"
automatic shutdown function, including overload protection, input
This series of pure sine wave inverter is suitable for : section before you use it to make sure it's safe to use. After
Household appliances: TV, refrigerator, freezer, washing machine, air conditioner, power high-low voltage protection, to prevent damage to your inverter ;
amplifier, induction cooker, electric fan, electric cooker Lamps and lanterns, AV equipment...... ●The inverter has advanced anti-interference technology, fully functional reading the instructions, please complete the warranty card for
Power tools: electric drills, pumps, cutting machines, motors, hand mills...... protection circuit and soft start circuit, convenient operation mode; safekeeping, to keep on for reference. 1
Office equipment: computers, printers, copiers, fax machines, network equipment......
●modify the string wave output, inverter provides AC, USBoutput interface;
On-board equipment:inverter can be connected to the car capacitor, suitable for all kinds
of on-board appliances. ●instantaneous power up to 1000W, efficiency as high as 94%.
Pure sine wave inverter front and rear panel diagram Install the connection step: Performance introduction
An inverter is a power supply that converts direct current (batteries, solar cells, wind turbines, etc.)
into alternating current. Because of the high frequency inverter used in power conversion
BEP150S Panel diagram
technology, ferrite transformer to replace the old bulky silicon steel transformer. This is why the
inverter of our company is lighter weight and less bulky than other inverters that have similar rated
power. When the inverter works in the inverter mode, the output waveform is modified sine wave. It
2
is a practical wave which waveform characteristic is similar to pure sine wave. This waveform is most
1 6
8 suitable for linear load and switching power supply of electronic equipment, such as light bulbs, rice
cookers, energy saving lamps, etc.. It can also be applied to inductive loads, such as transformers,
12V Connection diagram 24V-36V-48V-72V motors, etc.
4 3
Connection diagram The correct value of the modified sine wave for inverter output is 220V, which is the same as the
7
standard home power supply. Most AC voltmeters (digital and analog) use sensitive averaged
waveforms instead of RMS values.
Their calibration is set at RMS
Batter y Batter y Batter y voltage, which is used to measure
BEP300A/500SA Panel diagram pure waves. Using them to
24V-36V-48V-72V measure the output voltage of
2 12V Connection diagram Connection diagram the inverter, it is possible to
1 detect a low voltage 20V-30V. In
5 6 8 Refer to the above connection diagram order to measure accurately,
1.First turn off the power switch of the inverter. please use the voltmeter which
2.U se a black DC cable to connect the negative terminal of the batter y can measure the effective value.
11 7
to the black terminal of the inverter.
3.C onnect the positive terminal of the batter y to the red terminal of the
Using environment Pure sine wave
In order to achieve the best use effect, please put the inverter in the surface of the smooth place,
inverter with a red DC cable.
such as the ground, the floor of the car, or other solid surface. Let the inverter power line can be
BEP1000S Panel diagram 4.Plug the power supply plug of the power equipment into the output fixed easily. The working place should meet the following standards:
socket of the inverter. 1.Do not allow the inverter to contact with water or other liquid to keep the inverter away from
5.O pen the inverter power switch can be used. moisture or water.
5 2.In a cool environment, the temperature is 0 degrees (without condensation) to 40 degrees. Don't
2 8 Disassembly steps: put the inverter next to the heating vents or other heating devices. Keep the inverter out of the
1 6 7 sun as much as possible.
1.First turn off the power switch of the inverter;
3.Keeping the ventilation and the absence of obstructions around it ensures that air is free to
2.Pull out the power plug of the load.
11 circulate. When the inverter is working, do not put something on the inverter. The inverter fan is
3.Remove the red DC cable; used to help dissipate the heat.
4.Remove the black DC cable 4.Be careful not to use inverters near flammable materials or places where flammable gases can be
gathered.
BEP800S/1500S/2000S/3000S Panel diagram For example, when the power of an AC load is 100W, the current 5.The batter y not only provides a dc voltage of 11V to 15V, but also provides sufficient current to
supplied by the power supply must be 100/10=10A. In the need of a run the load. The power supply should be a good batter y full of electricity. To estimate roughly
larger current, you can use several batteries in parallel to use. The most the current required for a load, it can be estimated by dividing the power of the load by 10.
important thing is to ensure that there is enough cross-sectional area
9 10 6 7 of the connecting cable. This manual does not list all batter y pack Rated current and actual use of equipment
types. The batter y's charging and batter y configuration belong to The nominal current or power of most power tools, household appliances and video and audio
another professional categor y. equipment is much smaller than the nominal power range of the inverter, but overload protection
2 1 2 occurs when they are started. Inverter is the most easy to drive resistive load or switching power
supply load. Because the resistive load is a linear load, it can work full load. Such as electric stove,
11
8 8 Installation method rice cooker, LCD TV and other equipment.
1.Wiring diagram is only for basic reference, please contact professional technical Some audio-visual equipment and electric tools to a greater level than resistive load power can
personnel for actual installation. work normally, such as asynchronous motor, CRT TV, compressor, water pump etc. 2 to 6 times the
One or more batteries can be used in inverters. One or more batteries can be used in working current is required to start. The ability to run specific loads is subject to test.
Warming inverters. It's better to use 150AH or batteries with bigger capacity.
2.Since it may be necessar y to connect the batter y for these operations, make sure there is no Continuous frequently open and close inverters can cause damage.
BEP5000S Panel diagram flammable gas around before connecting.
Connect the inverter and the batter y with the cables supplied with the inverter (excluding the
Non-professional technicians, do not open inverter shell
Warming
high-power mode cable). The red cable is connected to the red terminal of the inverter input
terminal and the positive terminal of the batter y. The black cable is connected to the inverter Input
9 10
6
8
7 terminal black and batter y negative. Please ensure that all cables are stable and reliable.Improper Common problem
connection may result in overheating of the cable, damage to terminals and lugs. At the same time Electric tools and microwave ovens cannot start  
will cut down the batter y power supply time. Turn the inverter mode to ON, if your batter y is fully Carefully read the information on each power tool and accurately determine the input
2 1 2 charged, the light of inverter will display green. The inverter is protected if the light displays red, power of the tool. Whether the output power is enough to run the tools and microwave
so tr y to solve it before using.(Check whether the batter y voltage is too high or too low, the ovens, remember that power tools may need 2 to 6 times power requirements.
11 8 8 inverter output is overload or short circuit)。

12
The power source for the 12V inverter can be used with a 12V batter y or several 12V batteries in Television interference
parallel to increase the batter y's power supply time.
The inverter has little interference with the television signal. However, in some cases,
3.Inverter must be connected to the same nominal voltage of the batter y, 12V inverter
some disturbances are still visible, especially when the television signal is weak .
connected to the 12V batter y, 24V inverter connected to the 24V batter y
4.Before you plug in all your power devices, make sure all devices are shut down.
Please tr y the following methods:
Turn on the inverter mode switch, the POWER on the edge of the LED emits green light, and then 1.Tr y to keep the inverter away from the TV antenna or lengthen the TV antenna cable;
you can open your device one by one, if your device is not overloaded, now can work properly. If 2. Adjust the direction of the inverter.
LED glows red, it's overloaded .You need to reduce load restart to work . 3.Ensure that the antenna provides strong signal strength to the TV set, and use high
quality antenna cable with good shielding effect.
1、Power switch 7、Negative(black) ●.In the installation of connecting cables should use a suitable cable, such as 220V output 4.When you watch TV, do not run high power electrical equipment or tools.
2、AC output socket 8、Cooling fan cable is too long or the wire cross-sectional area is too small, there will be a lot of power
5.There is no way to completely disappear some of the old TV interference.
3、Power indicator 9、Voltage input monitor loss in the cable, the load side of the performance of small power, low voltage.
●.Batteries and inverter connection cable is not standardized, the cable is too long, the
4、Status indicator 10、Voltage output monitor cross-sectional area is too small, bad connection parts, will cause a lot of power loss. Normally the fuse will not burn out unless serious circuit failure occurs.
5、USB Interface 11、Double color status indicator Performance for the lack of output power, the battery voltage is too low, short working When the inverter fails, please do not tr y to repair it yourself. Please
6、Positive(red) 12、AC output interface hours, and even turn on the alarm does not work. At the same time the cable should be contact a professional technician to deal with the machine, there will be
waterproof, dielectric strength must meet the requirements of the use of the environment. Warming high voltage electric shock hazard.
The product panel is for reference only.Please refer to the actual product.
ZXP6-60 Series
Znshinesolar 5BB Polycrystalline PV Module

60
Mono Poly Solutions

270W丨275W丨280W丨285W丨290W丨295W丨300W
Made with selected materials and components to grant quality, dura-
tion, efficiency and through outputs, the ZXP6-60 polycrystalline
modules by ZNSHINE SOLAR represent a highly flexible solution for
diverse installation types, from industrial rooftop plants to small
home PV systems or large ground surfaces. This allows you to
produce clean energy while reducing your energy bill.

ZNSHINE SOLAR’S ZXP6-60 polycrystalline solar modules are tested


and approved by international acknowledged laboratories, so that we
can offer our customers a reliable and price-quality optimized prod-
uct. The linear warranty on product outputs further ensures increased
security and return on investments over time.

10 years workmanship warranty/25 years output warranty


0.7% Annual Degradation over 25 years
Znshine’s Standard

100% Industry Standard


Warranted Power Output

97.5%

90%

80.7%
80%

1 5 10 15 25
Years

Tier 1 & Bankable High Efficiency


5BB Well known trade mark in China; Graphene coating can increase about 2W of the module
Tier 1 bankable brand globally efficiency by rising around 0.5% of the light transmission

Anti-PID- PVEL Top Performer Better Weak Illumination Response


Limited power degradation of ZXP6-60 module Lower temperature coefficient and wide spectral
caused by PID effect is guaranteed under strict testing response, higher power output, even under low-light
condition for mass production settings

Certified to withstand the most Customerization——Grahpene Coating


challenging environmental conditions
Graphene coating modules can increase power generation
5400 Pa snow load and self-cleaning, also can save maintainance cost
2400 Pa wind load

ZNShine PV-Tech Co., LTD, founded in 1988, is a world-leading high-performance PV module manufacturer, PV power station developer, EPC and power station
operator. With its state-of-the-art production lines, the company boasts module output of 5GW. Bloomberg has listed ZNShine as a global Tier 1 PV manufacturer and
Top 4 reliable PV supplier. www.znshinesolar.com
ZXP6-60 Series Znshinesolar 5BB Polycrystalline PV Module

ELECTRICAL PROPERTIES 丨 STC*


ZXP6 ZXP6 ZXP6 ZXP6 ZXP6 ZXP6 ZXP6
Module Type 60-270/P 60-275/P 60-280/P 60-285/P 60-290/P 60-295/P 60-300/P

Nominal Power Watt Pmax(W) 270 275 280 285 290 295 300

Power Output Tolerance Pmax(%) 0~+3 0~+3 0~+3 0~+3 0~+3 0~+3 0~+3

Maximum Power Voltage Vmp(V) 31.1 31.3 31.5 31.7 31.9 32.1 32.3

Maximum Power Current Imp(A) 8.69 8.79 8.89 9.00 9.10 9.19 9.29

Open Circuit Voltage Voc(V) 38.7 38.9 39.1 39.3 39.5 39.7 39.9

Short Circuit Current Isc(A) 9.07 9.16 9.25 9.34 9.42 9.52 9.61

Module Efficiency (%) 16.50 16.80 17.11 17.41 17.72 18.02 18.33
*STC (Standard Test Condition): Irradiance 1000W/㎡, Module Temperature 25℃, AM 1.5
*The data above is for reference only and the actual data is in accordance with the pratical testing

ELECTRICAL PROPETIES 丨 NMOT*

Maximum Power Pmax(Wp) 199.7 203.3 207.1 211.2 215.2 218.1 222

Maximum Power Voltage Vmpp(V) 29.1 29.3 29.5 29.7 30.0 30.0 30.2

Maximum Power Current Impp(A) 6.87 6.95 7.03 7.11 7.17 7.26 7.34

Open Circuit Voltage Voc(V) 35.6 35.8 36.0 36.2 36.3 36.5 36.7

Short Circuit Current Isc(A) 7.34 7.42 7.49 7.56 7.63 7.71 7.78
*NMOT(Nominal module operating temperature):Irradiance 800W/㎡,Ambient Temperature 20℃,AM 1.5,Wind Speed 1m/s
*The data above is for reference only and the actual data is in accordance with the pratical testing

TEMPERATURE RATINGS MECHANICAL DATA

NMOT 45℃ ±2℃ Solar cells Poly 156.75×156.75 mm

Temperature coefficient of Pmax -0.40%/K Cells orientation 60(6×10)

Temperature coefficient of Voc -0.31%/K Module dimension 1650×992×35 mm

Temperature coefficient of Isc 0.06%/K Weight 19.5 kg

Glass High transparency,low iron,tempered


WORKING CONDITIONS
Glass 3.2mm (AR-coating)
Maximum system voltage 1000 / 1500 V DC
Junction box IP 68,3 diodes
Operating temperature -40℃~+85℃
Cables 4 mm² ,900 mm
Maximum series fuse 15 A
Connectors MC4-compatible
Maximum load(snow/wind) 5400 Pa / 2400 Pa

PACKAGING INFORMATION

Packing Type 40’HQ


DIMENSION OF THE PV MODULE(mm)
Piece/Box 30

Barcode 1 Piece/Container 840

junction box
Drainage holes
I-V CURVES OF THE PV MODULE
Barcode 2
10 315
Mounting holes
label
9 290 1,000 W/m2

8 265

7 240 800 W/m2


Current (A)

Power (W)

6 215

5 190 600 W/m2

4 165
Grounding mark

Grounding holes 3 140 400 W/m2

2 115

1 90 200 W/m2

0 0
0 5 10 15 20 25 30 35 40
Voltage ( V )

Add : 1#, Zhixi Industrial Zone,JintanJiangsu 213251,P.R. China Remark: please read safety and installation instructions before using the product丨Subject
Tel:+86 519 6822 0233 E-mail:info@znshinesolar.com to change without prior notice © ZNSHINE SOLAR 2019丨Version: ZXP6-60-1908.E

You might also like