You are on page 1of 10

measuring


Electromagnetic Flowmeter monitoring

all-metal design •
analysing

MIM

OO  or measuring and
F
monitoring of conductive
liquids
OO Accuracy:
< ± (0.8% of reading
+ 0.5% of full scale)
OO  low and temperature
F
measurement
Monitoring, transmitter

S5
OO
function, dosing
OO Bidirectional measuring
OO pmax: 16 bar; tmax: 140 °C
OO All-metal design:
stainless steel
OO Connection ½", ¾",1", 2"

-ve +ve
90

le
°r

ab
ot

io
at

n a
m

pro gr
gra
mm n pro
able tatio
90° ro

KOBOLD companies worldwide: KOBOLD Messring GmbH


Nordring 22-24
AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, D-65719 Hofheim/Ts.
GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, Head Office:
NETHERLANDS, PERU, POLAND, Republic  of  Korea, ROMANIA, RUSSIA, SPAIN, +49(0)6192 299-0
+49(0)6192 23398
SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM info.de@kobold.com
2/04 - 2020

www.kobold.com

1
Electromagnetic flowmeter in all-metal design Model MIM

Description
The new flowmeter MIM was developed for measuring and Mounting position: in all directions
monitoring smaller- and medium-sized flow of conductive In-/outlet: 3 x DN/2 x DN
liquids in pipes. Pressure drop: see pressure loss diagram
The device operates according to the electromagnetic Operation: 4 optical touch sensors,
measurement principle. According to Faraday’s Law of useable with hand gloves**
magnetic induction, a voltage is induced in a conductor
Housing: stainless steel 1.4404,
moving through a magnetic field. The electrically conductive display screen PMMA
measuring agent acts as the moved conductor. The voltage
induced in the measuring agent is proportional to the flow Wetted parts
velocity and is therefore a value for the volumetric flow. Connection fitting: stainless steel 1.4404
The flowing media must have a minimum conductivity. The Insulation parts: PEEK
induced voltage is picked up by two sensing electrodes Electrodes: stainless steel 1.4404
which are in contact with the measuring agent and sent to Seals: FKM (Option: EPDM)
the measuring amplifier.
Protection: IP 67
The flow rate will be calculated based on the cross sectional Media temperature: -20 °C … +70 °C (compact)
area of the pipe. -20 °C … +85 °C
The measurement is not depending on the process liquid (remote, PVC cable)
and its material properties such as density, viscosity and -40 °C … +140 °C
temperature. Two given outputs can be set to be switch, (remote, ETFE cable)
analogue or frequency. Also a dosing function can be Ambient temperature: -20 °C … +60 °C (compact version
selected, where output 1 is set as switch NPN / PNP / PP and and display for remote version)
output 2 is set as control input. -40 °C … +140 °C (sensor for
remote version with ETFE-cable)
Significant Characteristics
-20 °C … +85 °C (sensor for remote
OO Stainless steel design version with PVC-cable)
OO Flow- and temperature measurement Electrical data
OO Monitoring, dosing and transmitter function Supply voltage: 19 - 30 VDC, internal power
OO Dosing function with external control input consumption max. 200 mA
OO Coloured, multi-parameter configurable TFT-display, Display: TFT display, 128 x 128 pixels,
rotatable in 90° steps 1.4" display orientation in 90° steps
adjustable
OO Bidirectional measuring
Display repetition rate: 0.5 ... 10 s, adjustable
OO Intuitive setup menu via 4 optical touch keys
Pulse output Push-Pull, freely scalable,
OO 2 configurable outputs (pulse-/frequency-/alarm- and
configurable for partial and
analogue output) accumulated totaliser
OO Grand and resettable totaliser Frequency output Push-Pull, freely scalable,
Technical Details 2 kHz @ overflow
fmin @ FS = 50 Hz
Measurement process: electromagnetic
fmax @ FS = 1000 Hz
Range: see order details
Alarm output: NPN, PNP, Push-Pull,
Media: conductive fluids configurable max. 30 VDC, max.
Minimum conductivity: ≥20 µS/cm 200 mA short-circuit proof
Max. pressure: 16 bar Analogue output: active, 3 wire, 0(4)-20 mA,
Accuracy: <±(0.8 % of reading + 0.5 % of full scale)* max. load 500 Ω or 0(2)-10 VDC,
(Ri = 500 Ω)
Repeatability: ±0.2 % of full scale
Control input: active signal Uhigh max. 30 VDC
Response time flow t90 0 <Low <10 VDC
(alarm / pulse /  15 VDC <High <Vs
frequency output): <100 ms Dosing function: Dosing output OUT2:
(analogue output): <1 s Push-Pull, High active
Temperature measurement Control input OUT1:
Sensor: PT1000 START/STOP 0,5 s <thigh <4 s
RESET thigh >5 s
Accuracy: ≤±2 °C (flow >0.2 m/s)
Measuring range: temperature range of medium * Under reference conditions: media temperature: 15 °C ... 30 °C, 1 cSt,
Response time temperature t90 500 µS/cm, 1 bar
(signal output): <20 s ambience temperature: 15 °C ... 30 °C
 2/04 - 2020

** Limited functionality with black rubber gloves

2 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Electromagnetic flowmeter in all-metal design Model MIM

Technical Details (continued)


Electrical connection: plug M12x1, 4-pin Environmental testing
Shock resistance DIN EN 60068-2-30:2006: severity level b
DIN EN 60068-2-27:2010: 20 g (11 ms)
Vibration resistance
DIN EN 60068-2-6:2008: 5 g (10 … 2000 Hz)

Connection/ranges
Connection Inside diameter (DN) Range
G½ 5 mm 0,03 ... 3 l/min / 0.04 ... 10 l/min
G¾ 10 mm 0.1 ... 25 l/min / 0.2 ... 50 l/min
G1 15 mm 0.2 ... 50 l/min / 0.4 ... 100 l/min
G2 / 2" NPT see dimensional drawing 1.5 ... 350 l/min

Configuration of outputs
Output 1 (OUT1, PIN 4) Output 2 (OUT2, PIN 2)
Analogue output 4-20 mA Analogue output 4-20 mA
Analogue output 0-20 mA Analogue output 0-20 mA
Analogue output 2-10 V Analogue output 2-10 V
Analogue output 0-10 V Analogue output 0-10 V
Switching output NPN/PNP/PP Switching output NPN/PNP/PP
Pulse output PP Pulse output PP
Frequency output PP Frequency output PP
Communication mode KofiCom
Communication mode IO-Link
Control input
Control input dosing function Dosing output

IO-Link specification
Manufacturer ID: 1105 (decimal), 0 x 0451 (hex)
Manufacturer name: Kobold Messring GmbH
IO-Link specification: V1.1
Bitrate: COM3
Minimal cycle time: 1,1 ms
SIO-Mode: yes (OUT1 in configuration IO-Link)
Block parameterisation: yes
Operational readiness: 10 s
Max. cable length: 20 m

Electrical Connection MIM-…C3T

OUT 2

2 1

3 4
OUT 1
 2/04 - 2020

No responsibility taken for errors; www.kobold.com 3


subject to change without prior notice.
Electromagnetic flowmeter in all-metal design Model MIM

Order Details (Example: MIM-12 15H G5 C3T 0)


Model Range Connection Electronics Special version
03H1) = 0,03 ... 3 l/min
03G2) = 0.48 ... 48 GPH
G44) = G ½ male
05H1) = 0.04 ... 10 l/min
05G2) = 0.01 ... 2.6 GPM
MIM-12 = housing/ 10H1) = 0.1 ... 25 l/min C3T = compact, TFT display,
electrode 10G2) = 0.025 ... 6.6 GPM 2 outputs (current/voltage/
VA, FKM G54) = G ¾ male pulse/frequency/alarm output 0 = without
15H1) = 0.2 ... 50 l/min
seal configurable), M12x1 plug
15G2) = 0.05 ... 13 GPM K5) = including
MIM-134) = housing/ P023) = remote version, TFT display, calibration
electrode 15H1) = 0.2 ... 50 l/min 2m PVC cable, max. 85 °C report
VA, EPDM 15G2) = 0.05 ... 13 GPM E023) = remote version, TFT display,
G64) = G 1 male
seal 20H1) = 0.4 ... 100 l/min 2m ETFE cable, max. 140 °C
20G2) = 0.1 ... 26 GPM
35H1) = 1.5 ... 350 l/min G9 = G 2 male
N9 = 2" NPT
35G2) = 0.4 ... 90 GPM
female
1)
l/min-package (nameplate (l/min or ml/min, °C, bar)), calibrated range and temperature °C
2)
GPM-package (nameplate (GPM or GPH, °F, PSI)), calibrated range and temperature °F
3)
Cable length 02 = 2 m, 05 = 5 m, 10 = 10 m, 15 = 15 m, 20 = 20 m. Wall mounting brackets (brackets incl. accessories) is included in the scope of delivery.
4)
Regulation (EC) No. 1935/2004 for materials and articles intended to come into contact with food. Not for connection code G9/N9.
5)
Please specify number of measuring points in clear text.

Accessories (Spare part)


Description Model Image

Stainless steel wall mounting kit for remote


ERS-ZOK-023618
version (2 brackets, without nuts/washers)

Description Model Dimensions [mm] Image


15x6,5
15 x 6.5

Clamping bracket set


12

for wall mounting 100


(stainless steel with ZUB-MIM225128
partial polyolefin sleeve)
 2/04 - 2020

4 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Electromagnetic flowmeter in all-metal design Model MIM

Order Details MIM Fitting Sets Accessory Kits*


Accessory kit Meter / Fitting set type Dimensions [mm] Image
number Process
connection
49 49
49 39
SW 49
SW 36
36 SW
SW 32
32 SW
39
SW 24
24
G ½ cap nut/ Cap nut and
NPT

NPT

NPT
NPT

NPT

NPT
ZUB-AD2U15P08
1/1/222NPT

1/1/222NPT

1/1/444NPT
3/4"

2"
1"

3/4"

2"
GG3/4"

1/1/2"
¼" NPT male union
1"
GG1"

GG1/
G

G
1/

1/

1/
49 49
49
SW 49 39
39
SW 36
36 SW
SW 32
32 SW 24
SW 24
G ½ female/
NPTTT

NPT

NPTT
ZUB-AD2G15P15 Adapter
NPT
3/4NPT
3/4"

2"
NP

3/4"

½" NPT male


2"
1"1"

3/444NP

GG3/4"

1/1/2"

1/1/22NP
GG1"

GG1/
G

3/4
3/4

G
G
3/
3/

49
49 49 39
SW 49 39
SW 36
36 SW
SW 32
32 SW 24
24
SW
G ½ female/
NPTTT

NPT
NPT

ZUB-AD2G15N08 Adapter
NPT

1/1/44NPT
1/1/222NPT

3/4"

2"

¼" NPT female


3/4"

NP

2"
1"1"

GG3/4"

1/1/222NP

1/1/2"
GG1"

GG1/
G

G
1/

1/

49
49 49 39
SW 49 39
SW 36
36 SW
SW 32
32 SW 24
SW 24
G ½ female/
NPTTT

NPT

ZUB-AD2G15N15 Adapter
NPT
NPT
3/4NPT

NPT
1/1/222NPT
2"
3/4"

½" NPT female


NP
G1"

2"
3/4"
3/3/444NP

1/1/2"
GG3/4"
G1"
G1"

GG1/
3/4
3/4
G

G
3/

1/

49
49 49
49 39
SW 36 49
49 49
49 39
39
SW
SW 36
SW 36
36 SW
SW 32
32 39
SW 32
SW 32 SW
SW 24
SW 24
SW 24
24
G ¾ cap nut/ Cap nut and
NPT

NPT

NPT
NPT

NPT

NPT

ZUB-AD2U20P15
NPT

NPT

NPT
3/4"

2"
NPT

NPT

4444NPT
3/4"

2"
1"

3/4"

2"

½" NPT male union


1"

3/4"

2"
1"

1/1/
1"
GG

2222

2222

1/
1/
GG
G

GG
G

1/1/

1/1/

1/1/
G

G
G

G
1/

1/

1/
1/

1/

1/

49 49
49
49
49
49 49
49 39
39
SW
SW 36 39
39
SW 36
SW 36
36 SW
SW 32
SW 32
SW 32
32 SW 24
24
SW
SW 24
SW 24
G ¾ female/
TTTT

NPT

TTTT
NPT

ZUB-AD2G20P20 Adapter
NPT
NP

3/4"

2"

NP
3/4NPT
NP

3/4"

2"

NP

¾" NPT male


1"

NP

3/4"

2"

NP
4444NP

3/4"
1"

2"

NP
1"

1/
1"

1/
GG

2222
1/
1/
3/4
G

GG
GG

3/4
G

3/

1/1/
3/4
3/

G
G
3/

1/
G
G
3/

1/

49
49 49 39
49
49 49
49
49 39
39
39
SW
SW 36 SW 32
SW 36
SW 36
36 SW
SW 32
SW 32
32 SW 24
SW 24
SW 24
SW 24
G ¾ female/
TTTT

NPT
NPT

ZUB-AD2G20N15 Adapter
NPT
NPT

NPT
3/4"
NPT

NP

2"

4444NPT
NPT

3/4"

½" NPT female


NP

2"
1"

3/4"

NP

2"
3/4"
1"

NP

2"
1"

1/
1"

1/
GG

2222

2222

1/
1/
GG
G

GG
G

1/

1/1/

1/1/
G
1/

G
G
1/

1/

1/
1/

1/

1/

49
49 49 39
39
49
49 49
49
49 39
39
SW
SW 36
SW 36
SW 36
36 SW
SW
SW
32
32
SW 32
32 SW 24
24
SW
SW 24
SW 24
G ¾ female/
TTTT

NPT

NPT

ZUB-AD2G20N20 Adapter
NPT

NPT
NPT
NP

2"

NPT
3/4"

3/4NPT

¾" NPT female


NPT
NP

2"
3/4"
G1"

NP

2"
3/4"
G1"

4444NP

2"
3/4"
G1"

1/1/
G1"

2222
1/
1/
3/4
GG

GG
3/4
3/

1/1/
3/4
G

G
3/

G
3/

1/
3/

1/
 2/04 - 2020

* Note: All fitting kits include 2 x Klinger SIL® flat sealing gaskets

No responsibility taken for errors; www.kobold.com 5


subject to change without prior notice.
Electromagnetic flowmeter in all-metal design Model MIM

Order Details MIM Fitting Sets Accessory Kits* (continued)


Accessory kit Meter / Fitting set type Dimensions [mm] Image
number Process
connection
49 49 39
SW 36 49 49
49 39
SW 36 49
49 SW 32 49 39
SW
SW 36
36 SW 32 SW 24 39
SW
SW 32
32 SW
SW 24
SW 24
24

NPT

NPT
G1

2NPT

3/4"

2NPT

1/2"2"
Cap nut and

NPT

NPT
G1"1"

G3/4"
NPT

NPT
ZUB-AD2U25P15 cap nut/

3/4"

2"
3/4"
1"

2"
union

G1/
1"
GGG

1/1/
221/2

221/2
½" NPT male

GGG

GGG
1/1/1/

1/1/1/
49 49
SW 36 49 49
49 39
SW 36 49
49 SW 32 49 39
39
SW
SW 36
36 SW
SW 32 SW 24 39
SW 32
32 SW
SW 24
G1 SW 24
24

TTT T

NPT
Cap nut and

NPT
NP

3/4"

1/2"2"
cap nut/

NPT
ZUB-AD2U25P20
G1"1"

4NP

3/4"

NPT
NP

3/4"

2"
union

44NP

3/4"

2"
1"1"

3/4

G1/
¾" NPT male
GGG

1/1/
G

3/4
43/

3/4

GGG
GGG
3/

3/4
3/
3/
49 49 39
49
49 49 39
SW 36 49 SW 32 49 39
SW
SW 36 SW 32 49 SW 24 39
SW 36
36 SW
SW 32
32 SW 24
SW
SW 24
24
G 1 female/

TTT T
NPT

ZUB-AD2G25N15 Adapter

3/4"

NP

1/2"2"
2NPT
NPT
G1"1"

½" NPT female

G3/4"

2NP
NPT

3/4"

NP

2"
3/4"

NP

2"
1"1"

G1/
GGG

1/1/
1/2

221/2
GGG
22

GGG
1/1/1/

1/1/1/
49 49 39
SW 36 49
49 49 39
49 SW 32 49
49 39
39
SW
SW 36
SW 36
36 SW
SW 32
SW 32
32
SW 24
SW 24
G 1 female/ SW
SW 24
24
ZUB-AD2G25N20 Adapter
TTT T

NPT
¾" NPT female 45 Tri-Clamp® 1"

NPT
NP

1/2"2"
3/4"

SW 36

NPT
G1"

4NP

G3/4"

NPT
NP
G1"

2"
3/4"
44NP
G1"

2"
3/4"

3/4

G1/
G1"

1/1/
3/4
43/

GGG

3/4

GGG
3/

3/4
3/

Ø 22,1
3/

G 1"

45 Tri-Clamp® 1"
SW 36

G 1 female/
ZUB-AD2G25T25 Adapter
22,1
Ø 22.1
G 1"

1" Tri-Clamp®

SW 71 50
Tri-Clamp® 2"

G 2 female/
ZUB-AD2G50T50 Adapter
G 2"

47,5
Ø 47.5

SW 71 50
2" Tri-Clamp ®
Tri-Clamp® 2"
Ø
G 2"

Ø 47,5

* Note: All fitting kits include 2 x Klinger SIL® flat sealing gaskets or 2 x FKM O-rings (for ZUB-AD2G50T50)
 2/04 - 2020

6 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Electromagnetic flowmeter in all-metal design Model MIM

Pressure Loss
dP [mbar]
450
425
400
375
350
325
1
300
275
250
225 2
200
175
150
125 3
100 4
75 5
50 6
25 7
0
0,0 10,0 20,0 30,0 40,0 50,0 60,0 70,0 80,0 90,0 100,0
Q [%]

1 MIM-xx05xG4...
1 MIM-xx40xx9... 2 MIM-xx05xG4... 3 MIM-xx15xG5... 4 MIM-xx35xx9...
2 MIM-xx15xG5...6 MIM-xx10xG5... 7 MIM-xx03xG4... 8 MIM-xx15xG6...
5 MIM-xx20xG6...
3 MIM-xx35xx9...
4 MIM-xx20xG6...
5 MIM-xx10xG5...
6 MIM-xx03xG4...
7 MIM-xx15xG6...
 2/04 - 2020

No responsibility taken for errors; www.kobold.com 7


subject to change without prior notice.
Electromagnetic flowmeter in all-metal design Model MIM

Dimensions [mm]
Compact version

72 68

68
G

10 8 M 12 x 1

134 80
SW60

38x17
G 2"

80

200 Ø40
M 12 x1

134 80
2 " N PT I G
S W 65

38 x 17
80

200 Ø40
M12 x1
 2/04 - 2020

8 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Electromagnetic flowmeter in all-metal design Model MIM

Dimensions [mm] (continued)


Remote version
Without wall mounting brackets
104

68x68
13 4 108
72

M12 x1
G2 or 2" NPT

68x68
G

68 4xM5

200

42,4x 42,4
68
M12 x1

With wall mounting brackets


104
42,4
13 x 6,5

68x 68
115

13 4
108
72
G2 or 2" NPT

M12x1
68x 68
G

12 4
13x 6,5

68
4x M5

200
42,4
68

M12 x1
 2/04 - 2020

No responsibility taken for errors; www.kobold.com 9


subject to change without prior notice.
Electromagnetic flowmeter in all-metal design Model MIM

Measuring Mode, Display Layout »Single« configurable

OUT1 configured as 4-20 mA OUT2 disabled Configurable variables


and assigned to flow Flow rate Q
Volume AC
Temperature T
Display area for output status Q4-20mA OFF Part Volume PT
Font white: MV* within FS
Font yellow: 100% FS <= MV* <= OvFlow
Font red: MV* > OvFlow
0.000 4 digits + decimal point

Measuring variable with sign for direction +Q LPM Unit for measuring variable

INFO
Key symbol 1 Key symbol 2
(Menu functions) (Options INFO)
* Measured Value

Measuring Mode, Display Layout »Dual« configurable

OUT1 configured as switching output OUT2 configured as analogue output Configurable variables
Push-Pull and assigned flow 4-20 mA and assigned to temperature for both displays
Flow rate Q
Volume AC
Q SW+- T4-20mA Temperature T

0.850
Font white: MV within FS +Q Part Volume PT
Measuring variables
Font yellow: 100% FS <= MV <= OvFlow L/m
with sign for direction

17.5
Font red: MV > OvFlow +T
°C Unit for measuring variable

INFO

OUT1 configured as Pulse output OUT2 configured as analogue output


Push-Pull and assigned to Part Volume 4-20 mA and assigned to temperature

PT PLS T4-20mA
+PT
12345678 L

17.5
+T
°C

INFO
 2/04 - 2020

10 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.

You might also like