You are on page 1of 1

RapidCure

Corrosion Management Products


RapidCure UW

PRODUCT DESCRIPTION APPLICATION GUIDELINES


100% volume solids modified cold-cure RapidCure UW is applicable using brush, roller, spray (conventional
Technology
epoxy or airless), mitt, trowel etc. For best results underwater, sweating lines
Appearance Liquid coating in desired colour shade or waterponded areas, use brush for application.
Components Multi-component (2 Components)
Mix Ratio by Use “Xylene” as a cleaner. RapidCure UW does not require thinning.
5:1 by weight
Volume (A:B)
Cure Co-Reactive cure TYPICAL USES
Volume Solids 100±2% by volume RapidCure UW is recommended for application on structural steel and
Finish Glossy concrete/plastered substrates in:
Pot Life 30 minutes at 30º C
• Heavy chemical manufacturing industries
Typical Thickness Consult RapidCure
• Fertilizers and Petrochemicals
Recommended
Consult RapidCure • Oil & Gas upstream and downstream (for maintenance
Coats
painting)
Method of
Brush, Roller, Spray, Trowel, Mitt • Pipeline external coating
Application
• Pipeline internal lining
2-3 hours for above water applications
Touch Dry • Underwater areas
4-6 hours for underwater applications
• Hot surfaces up to 150º C
8 hours for above water applications
Hard Dry • Condensed surfaces
24 hours for underwater applications
• Tank external maintenance coating
4-6 hours for above water applications
Dry to Overcoat
24 hours for underwater applications
COATING SYSTEMS
Please consult Axial Group before specifying coating system.
RapidCure UW is low viscosity, non-solvent type, 100% volume solid
epoxy polyamine coating exhibiting excellent adhesion to most
IDEAL AMBIENT CONDITIONS
surfaces (steel, non- ferrous, plastics, wood, concrete, glass etc.).
Air Temperature 5º – 55º C
Excellent water, chemical, salt, oil resistance, underwater and low
Substrate Temperature 5º – 150º C
temperature curing capabilities. Used in wrapping systems for
excellent tensile strength. Relative Humidity 50% Minimum
95% Maximum
RapidCure UW is applied using brush or mitt underwater. Mixed liquid
STORAGE AND SHELF LIFE
coating remains unaffected even when submerged in sea water.
Available through Axial Group, their group companies and authorized
RapidCure UW’s low temperature curing capabilities prove excellent
distributors. Standard pack sizes are 5L and 16L.
when applied directly over sweating pipes or water ponded
substrates. RapidCure UW remains unaffected even when applied
Shelf Life: 2 Years from date of manufacturing when stored as
during rain, fog or damp situations.
recommended below.
TEST DATA
Storage Recommendations: Do not expose to freezing conditions.
Surface Preparation: Optimum storage temperature is 35º C.
St 3 as per ISO 8501-1:2007
LIMITED LIABILITY & WARRANTY
Salt Spray Test (ASTM Test Result: 4200 hours The information in this data sheet is not intended to be exhaustive.
B117) Any person using this product for any purpose other than that
Meets NORSOK M-501 specifically recommended either in this data sheet or by authorized
requirements of Salt Spray Test representatives of Axial Group does so at their own risk. All advice
given or statement made about the product (whether in the data sheet
Pull-Off Adhesion (ASTM or otherwise) is correct to our knowledge, however, we have no
~ 7-9 MPa – No failure observed
D4541) control on the quality and condition of the substrate being coated with
Cross-Cut Adhesion this product and hence Axial Group or their distributors do not assume
5A
(ASTM D3359 Method A) any liability arising out of misuse of this product. All safety precautions
Cured Tensile Strength must be taken while handling of this product. Please refer to MSDS
4,250 psi
(ASTM D3039) for more details.
Elongation at Break
0.8%
(ASTM D3039)
Issue date: November 2017 | Version: 1.0
Abrasion Resistance
20mg / 1000 cycles / 1 kg
(ASTM D4060)
Impact Resistance (ASTM
1 kg at 65 cm
D2794)
Fire Rating (BS:476) Class 1
Potable Water
No contamination of potable water
Compatibility (BS:6920)

SURFACE PREPARATION Distributed by:


Solvent cleaning as per SSPC SP1. Please refer to RapidCure for
specifics of surface preparation suitable for underwater, immersion
and atmospheric exposure areas.

In harsh environments such as C4M or C4I (ISO 12944), it is highly


recommended to conduct soluble salt test to identify presence of
Chloride Salts. Soluble salt, if any, shall be less than 20µg/cm2.
- Please consult your Axial Group sales representative for any technical clarifications or recommendations -

You might also like