14

63
,5
14 6
COPYRIGHT RESERVED

Y -86 100
Exist. 250Ø uPVC Cl 9 PIET RETIEF
4,0

BOULEVARD THIS DRAWING IS SUBJECT TO COPYRIGHT, AND MAY NOT BE


REPRODUCED IN PART OR WHOLE OR ANY MANNER WHATSOEVER
EXIST. CP I.L. 1461.89 WITHOUT THE WRITTEN PERMISSION FROM THE ARCHITECT
New SW MH
I.L. 1462.64 ORIGINAL SIZE
CP CP
14 375Ø EXISTING SW MOVE EXIST. CP TO 0cm 1 2 3 4 5 6
64

Y -86 000
A0

90Ø
,5 New 375Ø NEW POSITION

90Ø
SW PIPE
Bulk Water Meter to I.L. 1462.79 370.42
be installed
MH1 LAWN
LAWN MH2 Exist. MH3 GENERAL NOTES:
152.00m Site Boundary 152.00m Site Boundary
This is an COMPUTER generated drawing. All dimensions
Brick Wall 1.8m 600mm Paving Around Building Brick Wall 1.8m Brick Wall 1.8m Brick Wall 1.8m and levels to be checked and verified on site, by the
2m Building Line 2m Building Line 6000 RE contractors, prior to commencing any works.

BLOCK B BLOCK A ONLY use figured dimensions, NO scaling.

Precast Wall 1.8m


New SW MH All discrepencies on drawings or intended variations from

palisade fencing
New Electrical I.L. 1462.64 drawings are to be cleared with ARCHITECT before putting

Brick Wall 1.8m


Hydrant
Substation heat LAUNDRY, Ground: UNIT 33 Ground: UNIT 31 Ground: UNIT 29 Ground: UNIT 27 Ground: UNIT 25 Ground: UNIT 23 Ground: UNIT 1 Ground: UNIT 3 Ground: UNIT 5 Ground: UNIT 7 Ground: UNIT 9 LAUNDRY,

Brick Wall 1.8m


Exis. Electrical

Hydrant
any work in hand.

Slope 1:90
pump TV ROOM First: UNIT 46 First: UNIT 44 First: UNIT 42 First: UNIT 40 First: UNIT 38 First: UNIT 36

375Ø SW
First: UNIT 12 First: UNIT 14 First: UNIT 16 First: UNIT 18 First: UNIT 20 TV ROOM Substation All structural works are to be reffered to ENGINEERS

17.6
drawings and specifications.
1465 RE All works to be carried out in strict accordance with the
,0
FH FH 25.5 FH FH Yard National Building Regulations and the local council's
RE ie GARDEN ie GARDEN GARDEN RE ie GARDEN GARDEN RE RE GARDEN RE GARDEN
ie ie ie ie regulations.

40.4
30.1
GARDEN GARDEN GARDEN GARDEN GARDEN GARDEN GARDEN 90Ø uPVC CLASS 9 GARDEN A REVISION SCHEDULE
920 4000 4000 NR DATE DRAWN DESCRIPTION

2m Building Line
A 2014/08/08 NT (A) - Stairs move on Blocks J, K & L. (B) - Site
A REFUSE YARD stairs added to Blocks A, B, C, J, K & L. (C) -
Ground: UNIT 35 Ground: UNIT 34 Ground: UNIT 32 Ground: UNIT 30 Ground: UNIT 28 Ground: UNIT 26 Ground: UNIT 24

GATE HOUSE

5859
Ground: UNIT 2 Ground: UNIT 4 Ground: UNIT 6 Ground: UNIT 8 Ground: UNIT 10 Ground: UNIT 11 Precast wall and refuse yard moved as

PEDESTRIAN
First: UNIT 48 First: UNIT 47 First: UNIT 45 First: UNIT 43 First: UNIT 41 First: UNIT 39 First: UNIT 37 ie

ENTRANCE
First: UNIT 13 First: UNIT 15 First: UNIT 17 First: UNIT 19 First: UNIT 21 First: UNIT 22 heat RE indicated.

palisade fencing
pump roof over gulley

TAP & GULLEY


12013
63458 43606
LAWN LAWN 90Ø uPVC CLASS 9

5000

5000

5000
5000
2500 3600 3600 2500

OPEN GRID CP

375Ø CLASS 50D SW


60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

I.L. 1463.12
SW SW SW
FLO FLO FLO RE

BRAAI

OPEN GRID CP
W W W
35 Parking Bays Shade netting over

17000

I.L. 1462.83
49 Parking Bays Shade netting over

7001
7000
W
INTERLOCKING CONCRETE PAVING BLOCKS
W W
INTERLOCKING CONCRETE PAVING BLOCKS FACILITIES
FLO FLO FLO
61 62 63 64 65 SW 66 67 68 69 70 71 72 73 74 75 76 77 78 79 SW 80 81 82 83 84 35 34 33 32 SW 30 29 28 27 26 25 24 23 22 21 20 19 18
31

1462.44
2500 3600 3600 2500

palisade fencing

SW MH
5000
5000
5000

5000
RE G
LAWN LAWN IE IE
heat 61100
pump 46101
palisade fencing

14
65
,5
BLOCK D SW FLOW
BLOCK C

Hydrant
TV ROOM Ground: UNIT 91 Ground: UNIT 89 Ground: UNIT 87 Ground: UNIT 85 Ground: UNIT 83 Ground: UNIT 81 Ground: UNIT 79 6010 Ground: UNIT 49 Ground: UNIT 51 Ground: UNIT 53 Ground: UNIT 55 Ground: UNIT 57 Ground: UNIT 59 Ground: UNIT 61 LAUNDRY, heat

70.29 SITE BOUNDARY


First: UNIT 105 First: UNIT 103 First: UNIT 101 First: UNIT 99 First: UNIT 97 First: UNIT 95 First: UNIT 93 First: UNIT 64 First: UNIT 66 First: UNIT 68 First: UNIT 70 First: UNIT 72 First: UNIT 74 First: UNIT 76 TV ROOM pump

3 A
Business 1 FH RE FH FH FH palisade fencing
GARDEN RE GARDEN GARDEN RE RE GARDEN GARDEN RE GARDEN GARDEN GARDEN RE ie
0.4450 ha ie ie ie ie ie ie ie
90Ø uPVC CLASS 9

Slope 1:70
GARDEN GARDEN GARDEN GARDEN

375Ø SW
GARDEN GARDEN

Slope 1:75
LAUNDRY Ground: UNIT 92 Ground: UNIT 90 Ground: UNIT 88 Ground: UNIT 86 Ground: UNIT 84 Ground: UNIT 82 Ground: UNIT 80 Ground: UNIT 50 Ground: UNIT 52 Ground: UNIT 54 Ground: UNIT 56 Ground: UNIT 58 Ground: UNIT 60 Ground: UNIT 62 Ground: UNIT 63 A
First: UNIT 106 First: UNIT 104 First: UNIT 102 First: UNIT 100 First: UNIT 98 First: UNIT 96 First: UNIT 94 First: UNIT 65 First: UNIT 67 First: UNIT 69 First: UNIT 71 First: UNIT 73 First: UNIT 75 First: UNIT 77 First: UNIT 78
X 2 956 750 RE

2m Building Line
90Ø uPVC CLASS 9
New Precast Wall 1.8m
63600 68600

5000

5000

5000

5000
LAWN LAWN
2500 3600 3600 2500

163 162 161 160 159 158


S
157 156 155 154 153 152 151 150 149 148 147 146 145 144 143 142 141 140 139 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111
WF SW SW SW

OPEN GRID CP
FLO

OPEN GRID CP
LO FLO FLO
W W W W

I.L. 1463.62

I.L. 1462.78
49 Parking Bays Shade netting over 54 Parking Bays Shade netting over

17000

7000
7000
INTERLOCKING CONCRETE PAVING BLOCKS INTERLOCKING CONCRETE PAVING BLOCKS

Existing Precast Wall 1.8m


W W W W
FLO FLO FLO FLO
164 165 166 167 SW 169 170 171 172 173 174 175 176 177 178 179 180 SW 182 183 184 185 186 187 138 137 136 135 SW 133 132 131 130 129 128 127 126 125 124 123 122 121 SW 119 118 117 116 115 114 113 112
168 181 2500 3600 134 120
3600 2500

palisade fencing

palisade fencing
5000
5000

5000
5000
70.02 SITE BOUNDARY
LAWN LAWN
heat 68600 heat
pump 61100 pump

6000
BLOCK F BLOCK E
TV ROOM Ground: UNIT 151 Ground: UNIT 149 Ground: UNIT 147 Ground: UNIT 145 Ground: UNIT 143 Ground: UNIT 141 Ground: UNIT 139

Hydrant
Ground: UNIT 107 Ground: UNIT 109 Ground: UNIT 111 Ground: UNIT 113 Ground: UNIT 115 Ground: UNIT 117 Ground: UNIT 119 Ground: UNIT 121 TV ROOM
First: UNIT 165 First: UNIT 163 First: UNIT 161 First: UNIT 159 First: UNIT 157 First: UNIT 155 First: UNIT 153 First: UNIT 123 First: UNIT 125 First: UNIT 127 First: UNIT 129 First: UNIT 131 First: UNIT 133 First: UNIT 135 First: UNIT 137

375Ø CLASS 50D SW


A A
FH RE GARDEN RE FH RE ie RE FH RE FH RE ie
ie ie GARDEN ie GARDEN ie GARDEN GARDEN ie GARDEN ie GARDEN GARDEN ie ie
90Ø uPVC CLASS 9

Slope 1:70
GARDEN GARDEN GARDEN
RE
VACANT GARDEN GARDEN GARDEN

375Ø CLASS 50D SW


LAUNDRY Ground: UNIT 152 Ground: UNIT 150 Ground: UNIT 148 Ground: UNIT 146 Ground: UNIT 144 Ground: UNIT 142 Ground: UNIT 140
Ground: UNIT 108 Ground: UNIT 110 Ground: UNIT 112 Ground: UNIT 114 Ground: UNIT 116 Ground: UNIT 118 Ground: UNIT 120 Ground: UNIT 122 LAUNDRY
First: UNIT 166 First: UNIT 164 First: UNIT 162 First: UNIT 160 First: UNIT 158 First: UNIT 156 First: UNIT 154
First: UNIT 124 First: UNIT 126 First: UNIT 128 First: UNIT 130 First: UNIT 132 First: UNIT 134 First: UNIT 136 First: UNIT 138
SW FLOW

INTERLOCKING CONRETE
5000

178.40m Site Boundary


PAVING BLOCKS
LAWN
2500 3600

14 211 210 209 208 207 506 205 204 203 202 201 200 199 198 197 196 195 194 193 192 191 190 189 188
66 SW

OPEN GRID CP
,0 SW FLO

OPEN GRID CP
FLO W
2m Building Line

I.L. 1464.12

I.L. 1463.56
17000

17000
7000

7000
48 Visitors Parking Bays

INTERLOCKING CONCRETE PAVING BLOCKS W


W
LO FLO
S WF SW
212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239
5000

146307

Rem of Erf 2
70.29 SITE BOUNDARY

Existing Precast Wall 1.8m


PTN 141 OF ERF 2 SE 10
New Precast Wall 1.8m

JOB TITLE & LOCATION:

ERF SIZE: 27 091m² PROPOSED DEVELOPMENT


PTN 141 OF ERF 2. SE 10,
FOOTPRINT AREA: 5 792.95m² VANDERBIJLPARK
COVERAGE: 21.4%

C:\Users\Niel\Desktop\2016\1724 VUT\REVIT\File 1 - VUT.Working Drawings.2014.10.23.rvt


PARKING PROVIDED:
Covered parking required = 166 bays ISSUED FOR CONSTRUCTION
Covered parking provided = 187 bays
2m Building Line

2m Building Line
Open parking required = 56 bays SITE PLAN
Open parking provided = 52 bays

178.40m Site Boundary


14
66 DRAWING TITLE:
,5

SCALE: DRAWN BY:


Total parking required = 222 bays X 2 956 850
1 : 250 NT
Total parking provided = 239 bays
DESIGNED: DIRECTOR:
WK WK
PROJECT NO: DRAWING NO:
2m Building Line 2m Building Line
1724 000

2016-10-10 07:55:38 AM
SITE PLAN New Precast Wall 1.8m 222.04 SITE BOUNDARY New Precast Wall 1.8m