You are on page 1of 2

Preparation of DPR for the WORK of Grade Separator Connecting Medavakkam – Sholinganallur Road Junction, Levels Statement and

Levels Statement and Grouping of Superstructure and Substructure


Medavakkam – Mambakkam Road Junction Mount Medavakkam Road Junction

LEVELS STATEMENT AND GROUPING OF PIERS, ABUTMENTS & SPANS FOR DESIGN
Width of Deck Max/Min. Max/Min. Height of Bearing
Span along the Slab Pedastals Depth of
Cantiliver Cantiliver RCL @ Thickness
Central Line Spacing of Existing GL Founding Super Height Type
S. No. Support Chainage On On Width of Width of centreline of of bearing Remarks
(c/c of exp. Girders Outer Inner RL(+) Level RL(+) Structure Difference Design
Inner Outer Deck on Deck on road in mm
Joints) Pedastals Pedastals in m
Side Side Inner Side Outer Side

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) = (9)-(13) (17) (18)
Tambaram - Velacherry Arm (RHS Arm towards increasing chainage)

1 P 14 12+426 20.00 7.250 6.900 3.125 2.775 2.750 110.700 0.345 0.220 98.972 95.472 2.000 96 15.228 PD 4
2 P 15 12+446 20.00 6.834 6.600 2.709 2.475 2.750 110.700 0.280 0.220 98.921 95.421 2.000 96 15.279 PD 4 Transition Portion

3 P 16 12+466 20.00 6.417 6.300 2.292 2.175 2.750 110.700 0.215 0.220 98.931 95.431 2.000 96 15.269 PD 4
4 P 17 12+486 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 98.989 95.489 2.000 96 15.211 PD 4
5 P 18 12+506 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 99.165 95.665 2.000 96 15.035 PD 4
6 P 19 12+526 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 99.259 95.759 2.000 96 14.941 PD 4
7 P 23 12+620 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 99.969 96.469 2.000 96 14.231 PD 4
8 P 24 12+640 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 100.167 96.667 2.000 96 14.033 PD 4
9 P 44 13+040 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 99.923 96.423 2.000 96 14.277 PD 4
10 P 45 13+060 20.00 6.000 6.000 1.875 1.875 2.750 110.680 0.150 0.220 99.759 96.259 2.000 96 14.421 PD 4
11 P 46 13+080 20.00 6.000 6.000 1.875 1.875 2.750 110.618 0.150 0.220 99.565 96.065 2.000 96 14.553 PD 4
12 P 47 13+100 20.00 6.000 6.000 1.875 1.875 2.750 110.516 0.150 0.220 99.144 95.644 2.000 96 14.872 PD 4
13 P 48 13+120 20.00 6.000 6.000 1.875 1.875 2.750 110.393 0.150 0.220 99.119 95.619 2.000 96 14.774 PD 4
14 P 49 13+140 20.00 6.000 6.000 1.875 1.875 2.750 110.270 0.150 0.220 99.073 95.573 2.000 96 14.697 PD 4
15 P 50 13+160 20.00 6.000 6.000 1.875 1.875 2.750 110.148 0.150 0.220 98.971 95.471 2.000 96 14.677 PD 4
16 P 51 13+180 20.00 6.000 6.000 1.875 1.875 2.750 110.025 0.150 0.220 98.868 95.368 2.000 96 14.657 PD 4
17 P 52 13+200 20.00 6.000 6.000 1.875 1.875 2.750 109.902 0.150 0.220 98.755 95.255 2.000 96 14.647 PD 4
18 P 53 13+220 20.00 6.000 6.000 1.875 1.875 2.750 109.779 0.150 0.220 98.672 95.172 2.000 96 14.607 PD 4
19 P 54 13+240 20.00 6.000 6.000 1.875 1.875 2.750 109.656 0.150 0.220 98.588 95.088 2.000 96 14.568 PD 4
20 P 55 13+260 20.00 6.000 6.000 1.875 1.875 2.750 109.534 0.150 0.220 98.497 94.997 2.000 96 14.537 PD 4
21 P 56 13+280 20.00 6.000 6.000 1.875 1.875 2.750 109.411 0.150 0.220 98.395 94.895 2.000 96 14.516 PD 4
22 P 57 13+300 20.00 6.000 6.000 1.875 1.875 2.750 109.288 0.150 0.220 98.087 94.587 2.000 96 14.701 PD 4
23 P 58 13+320 20.00 6.000 6.000 1.875 1.875 2.750 109.165 0.150 0.220 97.977 94.477 2.000 96 14.688 PD 4
24 P 59 13+340 20.00 6.000 6.000 1.875 1.875 2.750 109.042 0.150 0.220 97.895 94.395 2.000 96 14.647 PD 4
25 P 60 13+360 20.00 6.417 6.300 2.292 2.175 2.750 108.920 0.215 0.220 97.707 94.207 2.000 96 14.713 PD 4
26 P 61 13+380 20.00 6.834 6.600 2.709 2.475 2.750 108.797 0.280 0.220 97.505 94.005 2.000 96 14.792 PD 4 Transition Portion

27 P 62 13+400 20.00 7.250 6.900 3.125 2.775 2.750 108.674 0.345 0.220 97.382 93.882 2.000 96 14.792 PD 4
Circular Curve
28 P 63 13+420 20.00 7.250 6.900 3.125 2.775 2.750 108.551 0.345 0.220 97.129 93.629 2.000 96 14.922 PD 4
Portion

Vax Consultants Pvt. Ltd.,


CMDP III, DIVISION IV, ALANDUR, CHENNAI. Foundation & Structural Engineers
Preparation of DPR for the WORK of Grade Separator Connecting Medavakkam – Sholinganallur Road Junction, Levels Statement and Grouping of Superstructure and Substructure
Medavakkam – Mambakkam Road Junction Mount Medavakkam Road Junction

LEVELS STATEMENT AND GROUPING OF PIERS, ABUTMENTS & SPANS FOR DESIGN
Width of Deck Max/Min. Max/Min. Height of Bearing
Span along the Slab Pedastals Depth of
Cantiliver Cantiliver RCL @ Thickness
Central Line Spacing of Existing GL Founding Super Height Type
S. No. Support Chainage On On Width of Width of centreline of of bearing Remarks
(c/c of exp. Girders Outer Inner RL(+) Level RL(+) Structure Difference Design
Inner Outer Deck on Deck on road in mm
Joints) Pedastals Pedastals in m
Side Side Inner Side Outer Side

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) = (9)-(13) (17) (18)
29 P 64 13+440 20.00 7.250 6.900 3.125 2.775 2.750 108.428 0.345 0.220 97.198 93.698 2.000 96 14.730 PD 4
30 P 65 13+460 20.00 6.834 6.600 2.709 2.475 2.750 108.306 0.280 0.220 97.374 93.874 2.000 96 14.432 PD 4 Transition Portion
31 P 66 13+480 20.00 6.417 6.300 2.292 2.175 2.750 108.183 0.215 0.220 97.298 93.798 2.000 96 14.385 PD 4
32 P 67 13+500 20.00 6.000 6.000 1.875 1.875 2.750 108.060 0.150 0.220 97.143 93.643 2.000 96 14.417 PD 4
33 P 68 13+520 20.00 6.000 6.000 1.875 1.875 2.750 107.937 0.150 0.220 97.128 93.628 2.000 96 14.309 PD 4
34 P 69 13+540 20.00 6.000 6.000 1.875 1.875 2.750 107.814 0.150 0.220 97.121 93.621 2.000 96 14.193 PD 4
35 P 97 12+465.23 20.00 6.417 6.300 2.292 2.175 2.750 110.700 0.215 0.220 99.231 95.731 2.000 96 14.969 PD 4
36 P 98 12+485.23 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 99.206 95.706 2.000 96 14.994 PD 4
37 P 99 12+505.23 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 99.163 95.663 2.000 96 15.037 PD 4
38 P 100 12+525.23 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 99.274 95.774 2.000 96 14.926 PD 4
39 P 101 12+545.23 20.00 6.000 6.000 1.875 1.875 2.750 110.700 0.150 0.220 99.372 95.872 2.000 96 14.828 PD 4
NOTES :
PD 4 = Typical Pier Design 4 for heights above 14.0m and 20.0m Spans, for design levels taken for P 15 - Total 39 Nos.

Vax Consultants Pvt. Ltd.,


CMDP III, DIVISION IV, ALANDUR, CHENNAI. Foundation & Structural Engineers