You are on page 1of 3

XMAS TREE GENERAL INFORMATION

 First oil: 18th, October 1994;


 Subsea Tree Type: CBV Vertical Tree;
- Umbilical length: 332m; Made by DUCO;
- Flowlines length: 2x332m.

V-Tree arrangement Flow schematic


1
DAI HUNG DH-1 INFORMATION

DH-1P, 2P,
3P beneath
the FPU
DH-01;
 Water
depth:
110M
MDP:
50M

Catenary
Anchor
Block
(C.A.B
Cluster DH-1P, 2P, Line
3P No_8
from
AFT
WELL UPDATE STATUS
Line Max Working
Function ID Status
No. Pressure (Psi)

DH-1P DH-2P DH-3P

1 SSSV-A 1/4" 7,500 Over-ride Good Over-ride


2 SSSV-A Lock 1/4" 7,500 Lock open Good Lock open
Pressure
3 SSSV-B 1/4" 7,500 Passing build up Close
4 SSSV-B Lock 1/4" 7,500 Good Good Good
5 MON 1/4" 7,500 Good Good Good
6 PMV 1/4" 3,000 Good Good Good
7 AMV 1/4" 3,000 Good Good Good
8 PWV 1/4" 3,000 Good Leaking Passing
9 AWV 1/4" 3,000 Good Good Good
10 XOV 1/4" 5,000 Good Leaking Passing
Check valve
11 CI 1/2" 3,000 Good fail Good
12 CI Spare 1/4" 7,500 Good Good Good
Shut-in pressure,
13 bar 37 146 124