Function overview
87BB
86
Features 1
• Optimized for single busbar and 1½ circuit-breaker
configurations
• Suitable for double busbars with or without couplers
• Separate check zone possible
2
• Short trip times
• Unlimited number of feeders
• Matching of different primary CT ratios 3
LSP2363-afpen.tif
• Differential current principle
• Low-impedance measuring method
• Numerical measured-value processing
• Suitable for all voltage levels
4
• Low demands on CTs thanks to additional restraint
• Measured-value acquisition via summation current transformer
or phase-selective matching transformers 5
• Maintained TRIP command (lockout function)
• Centralized, compact design
Fig. 9/1 7SS601 measuring system
• Combinative with separate breaker failure protection
6
Monitoring functions
Description
• Primary current transformers including supply leads
The SIPROTEC 7SS60 system is an inexpensive numerical
differential current protection for busbars in a centralized
• Operational measured values: Differential and restraint current
• Self-supervision of the relay
7
configuration. • 30 event logs
It is suitable for all voltage levels and can be adapted to a large • 8 fault logs
variety of busbar configurations with an unlimited number
of feeders. The components are designed for single busbars,
• 8 oscillographic fault records 8
1½-breaker configurations and double busbars with or without Communication interface
couplers.
• RS485 interface for local and remote operation with DIGSI
Different primary CT ratios can be matched by using appropriate 9
windings of the input current transformers.
The use of matching transformers allows phase-selective mea- Hardware
surement. Single-phase measurement can be achieved by using
summation current transformers.
• Concept of modular components 10
• Reduced number of module types
• Auxiliary voltage DC 48 V to DC 250 V
• 7SS601 measuring system in ¹/₆ 19-inch housing 7XP20
• Peripheral components in ½ 19-inch housing 7XP20
11
Front design
• Display for operation and measured values
• 6 LEDs for local indication
12
13
14
15
Siemens SIP · Edition No. 7 9/3
Busbar Differential Protection / 7SS60
Application
Application
10
11
12
13
14
15
9/4 Siemens SIP · Edition No. 7
Busbar Differential Protection / 7SS60
Construction, functions
LSP2803.tif
1
2
LSP2383-afp.tif
LSP2803.tif
3
4
Fig. 9/3 Housing for peripheral modules Fig. 9/4 Rear view Fig. 9/5 Rear view detail
(front cover removed)
5
Construction Functions
15
Siemens SIP · Edition No. 7 9/5
Busbar Differential Protection / 7SS60
Protection functions
5
Fig. 9/6 Block diagram: Acquisition of measured values
15
9/6 Siemens SIP · Edition No. 7
Busbar Differential Protection / 7SS60
Typical connections
Typical connections
SIPV6.012en.eps
2
3
Fig. 9/7 Protection with summation current transformer
(L1-L2-L3 circuit)
6
Fig. 9/8 Protection with summation current transformer
(L1-L3-N circuit) 7
10
Fig. 9/9 Protection with summation current transformer and
matching transformers
11
12
13
14
Fig. 9/10 Phase-selective measurement
15
Siemens SIP · Edition No. 7 9/7
Busbar Differential Protection / 7SS60
Protection functions
10
11
12
13
14
15
9/8 Siemens SIP · Edition No. 7
Busbar Differential Protection / 7SS60
Communication
Communication
LSA2747-cgpen.eps
the restraint current are recorded with a
sampling frequency of 2 kHz. In addition,
signals are stored as binary traces, which
represent internal device states or binary
input states. Up to eight fault records 10
can be stored. When a ninth fault occurs,
Fig. 9/13 Communication scheme
the oldest record is overwritten. A total
storage capacity of 7 s is available. The
most recent 2.5 s are buffered against 11
power failure.
12
13
14
15
Siemens SIP · Edition No. 7 9/9
Busbar Differential Protection / 7SS60
Technical data
1 Measuring input Id
Rated current 100 mA
Number of relays 1 (2 NO contacts)
1 (1 NO contact)
2 (pulse current)
Thermal overload capacity (r.m.s.) 100 x IN for ≤ 1 s
Switching voltage
Permissible current
AC/DC 250 V
3 observed)
Isolating voltage 2.5 kV (r.m.s.)
Signal contacts
Number of relays 3 (2 marshallable)
Measuring range for operational 0 to 240 % Contacts 2 changeover contacts and 1 NO
measured values contact (can be changed to NC by
jumper)
4 Measuring dynamics 100 x IN without offset
50 x IN with full offset Switching capacity
Measuring input IR Make 1000 W/VA
Break 30 W/VA
Rated current 1.9 mA
Switching voltage AC/DC 250 V
5 Dynamic overload capability
(pulse current)
250 x IN for 10 ms
Permissible current
Continuous 5A
Thermal overload capability (r.m.s.) 100 x IN for ≤ 1 s 0.5 s 30 A
(where external summation or 30 x IN for ≤ 10 s
matching current transformers 4 x IN continuous Serial interface
7 Auxiliary voltage
Via integrated DC/DC converter DC 24/48 V (DC 19 to 58 V)
For connection of a personal
computer or similar
Cables must be shielded, and shields
Rated auxiliary voltage Vaux DC 60/110/125 V (DC 48 to 150 V) must be grounded.
(permissible voltage) DC 220/250 V (DC 176 to 300 V)
AC 115 V (AC 92 to 133 V) As delivered 9600 baud
8 Superimposed AC voltage ≤ 15 % of rated voltage
Unit design
min. 1200 baud, max. 19200 baud
(peak-to-peak)
Power consumption Quiescent Approx. 3 W Housing 7XP20 ¹/₆ 19"
Energized Approx. 5 W Dimensions See part 14
9 Bridging time during failure /
short-circuit of auxiliary voltage
≥ 50 ms at Vaux ≥ DC 100 V
≥ 20 ms at Vaux ≥ DC 48 V
Weight Approx. 4.0 kg
Degree of protection according
Binary inputs to IEC 60529-1
Number 3 (marshallable) For the unit IP 51
13
14
15
9/10 Siemens SIP · Edition No. 7
Busbar Differential Protection / 7SS60
Technical data
Time stamping
tions of the last 8 faults
Switching time < 20 ms 8
Resolution for operational 1 ms Number of auxiliary relays 1
annunciation Contacts of auxiliary relay 2 changeover contacts
Resolution for fault annunciation 1 ms
Fault recording (max. 8 fault) Buffered against voltage failure
(last 2.5 s)
Auxiliary voltage
Rated auxiliary voltage Vaux DC 48/60 V (DC 38 to 72 V)
9
Recording time Max. 7.1 s total (permissible voltage range) DC 110/125 V (DC 88 to 150 V)
(from fault detection) Pre-trigger and post-fault time DC 220/250 V (DC 176 to 300 V)
can be set Depending on the design
Max. length per record
Pre-trigger time
0.2 to 5.0 s (in steps of 0.01 s)
0.05 to 1.5 s (in steps of 0.01 s)
Relay contacts 10
Switching capacity
Post-fault time 0.01 to 1.5 s (in steps of 0.01 s)
Make 1000 W/VA
Sampling frequency 2 kHz
Break 30 W/VA
Peripheral modules
Switching voltage
Permissible current
AC/DC 250 V 11
7TM700 restraint/command output module Continuous 5A
0.5 s 10 A
Measuring input IR
Number of restraint units
Rated current
5
100 mA
Weight Approx. 0.6 kg
12
Rated frequency 16.7, 50, 60 Hz
Dynamic overload capacity 250 x IN one half cycle
(pulse current)
Thermal overload capacity (r.m.s.) 100 x IN for ≤ 1 s
13
(where external summation or 30 x IN for ≤ 10 s
matching current transformers 4 x IN continuous
are used, their limit data must be
observed) 14
1) Each additional intermediate relay increases the tripping time by 7 ms.
2) Each additional intermediate relay increases the reset time by 8 ms.
3) Limited by the continuous power dissipation of the device. 15
Siemens SIP · Edition No. 7 9/11
Busbar Differential Protection / 7SS60
Technical data
7 Type
For conductor cross-sections of
e.g. PDIG of AMP
2.7 to 6.6 mm2
4AM5120-1DA00-0AN2
For connection to current
AWG 12 to 10
In parallel double leaf-spring- 2.5 to 4.0 mm2 transformers with a rated
crimp contact for conductor AWG 13 to 11 current IN of 1A
8 cross-sections of
Max. tightening torque 3.5 Nm
Rated frequency fN
Winding
45-60 Hz
A-B B-C D-E E-F G-H H-J Y-Z
Control connections (terminals 7 to 31) Number of turns 1 2 4 8 16 32 500
Screw-type terminals For 4 mm bolts Max. current, continuous A 6.8 6.8 6.8 6.8 6.8 6.8 0.85
Max. voltage V 0.4 0.8 1.6 3.2 6.4 12.8 200
9 (ring-type cable lug)
Max. outside diameter 9 mm Max. burden VA 1.0
Type e.g. PDIG of AMP 4AM5120-2DA00-0AN2
For conductor cross-sections of 1.0 to 2.6 mm2
AWG 17 to 13 For connection to current
12
13
14
Summation current matching transformers EMC tests for interference immunity; type tests
4AM5120-3DA00-0AN2
For connection to current
Standard IEC 60255-6, IEC 60255-22
(international product standards)
EM 50Ω082-2
1
transformers with a rated
current IN of 1A (technical generic standard)
DIN VDE 57435 part 303
Rated frequency fN 45-60 Hz (German product standard for
Winding
Number of turns
A-B C-D E-F
3 6 9
G-H J-K
18 24
L-M N-O Y-Z
36 90 500
protection devices) 2
High-frequency test 2.5 kV (peak); 1 MHz; t = 15 ms;
IEC 60255-22-1, 400 surges per s; test duration 2 s
Max. current, continuous A 4 4 4 4 4 4 2 0.85 DIN 57435 part 303; class III
Max. voltage V 1.2 2.4 3.6 7.2 9.6 14.4 36 200 Electrostatic discharge
IEC 60255-22-2; IEC 61000-4-2;
8 kV contact discharge;
15 kV air discharge;
3
Max. burden VA 1.8 class IV both polarities; 150 pF; Ri = 330 Ω
4AM5120-4DA00-0AN2 Irradiation with RF field, 10 V/m; 27 to 500 MHz
non-modulated
For connection to current
transformers with a rated
current IN of 5A
IEC 60255-22-3 (report); class III 4
Irradiation with RF field, 10 V/m; 80 to 1000 MHz;
Rated frequency fN 45-60 Hz amplitude-modulated 80 % AM; 1 kHz
IEC 61000-4-3, class III
Winding A-B C-D E-F G-H J-K L-M N-O Y-Z
Number of turns 1 2 3 4 6
Max. current, continuous A 17.5 17.5 17.5 17.5 17.5 17.5 8.0
8 12 500
0.85
Irradiation with RF field,
pulse-modulated
10 V/m; 900 MHz;
repetition frequency 200 Hz; ED 50 %
5
IEC 61000-4-3 / ENV 50204; class III
Max. voltage V 0.4 0.8 1.2 1.6 2.4 3.2 4.8 200
Fast transient disturbance / bursts 4 kHz; 5/50 ns; 5 kHz, burst length
Max. burden VA 2.5 IEC 60255-22-4; IEC 61000-4-4; = 15 ms; repetition rate 300 ms;
class III both polarities; Ri = 50 Ω;
test duration 1 min
6
Matching transformer
High-energy surge voltages Auxiliary voltage:
4AM5272-3AA00-0AN2 (SURGE), Longitudinal test: 2 kV; 12 Ω; 9 µF
Multi-tap auxiliary current
transformer to match
different c.t. ratios
IEC 61000-4-5, installation, class III Transversal test: 1 kV; 2 Ω; 18 µF
Measuring inputs, binary inputs
and relay outputs:
7
Rated frequency fN 45-60 Hz Longitudinal test: 2 kV; 42 Ω; 0.5 µF
Transversal test: 1 kV; 42 Ω; 0.5 µF
Winding A-B C-D E-F G-H J-K L-M N-O P-Q
Number of turns
Max. current, continuous A 6
1 2
6
7
6
16 1
1.2 6
2
6
7
6
16
1.2
Line-conducted HF,
amplitude-modulated
10 V; 150 kHz to 80 MHz;
80 % AM; 1 kHz 8
IEC 61000-4-6; class III
Max. voltage V 4 8 28 64 4 8 28 64 Magnetic field with power
resistance Ω 0.018 0.035 0.11 1.05 0.018 0.035 0.11 1.05 frequency
Electrical tests
IEC 61000-4-8; class IV
IEC 60255-6
30 A/m; continuous; 300 A/m for 3 s;
50 Hz; 0.5 mT
9
Oscillatory surge 2.5 to 3 kV (peak); 1 to 1.5 MHz;
Specifications withstand capability damped wave; 50 surges per s;
Standards: IEC 60255-5; ANSI/IEEE C37.90.0 ANSI / IEEE C37.90.1 duration 2 s; Ri = 150 to 200 Ω
Insulation tests Fast transient surge
withstand capability
4 to 5 kV; 10/150 ns; 50 surges
per s; both polarities; duration 2 s;
10
High voltage test (routine test), 2.5 kV (r.m.s.); 50 Hz
ANSI / IEEE C37.90.1 Ri = 80 Ω
measuring input Id and relay outputs
Radiated electromagnetic 35 V/m; 25 to 1000 MHz
High voltage test (routine test), DC 3.5 kV
auxiliary voltage input and RS485
interface, binary inputs and
interference ANS / IEEE C37.90.2
Damped oscillations
11
measuring input IR IEC 61000-4-12 2.5 kV (peak, alternating polarity);
IEC 60694 100 kHz; 1, 10 and 50 MHz;
Impulse voltage test (type test), 5 kV (peak); 1.2/50 µs; 0.5 J;
damped wave; Ri = 50 Ω
all circuits, class III 3 positive and 3 negative
impulses in intervals of 5 s EMC tests for interference emission; type test 12
Standard EN 50081-*
(technical generic standard)
Conducted interference voltage on 150 kHz to 30 MHz,
lines only auxiliary voltage,
EN 55022, DIN VDE 0878 part 22,
limit value, class B 13
IEC CISPR 22
Radio interference field strength 30 to 1000 MHz,
EN 55011; DIN VDE 0875 part 11,
IEC CISPR 11
limit value, class A
14
15
Siemens SIP · Edition No. 7 9/13
Busbar Differential Protection / 7SS60
Technical data
10 Temperatures
Standards IEC 60255-6
Permissible ambient temperatures
– In service -20 to +45/55 °C
11 – During storage
– During transport
-25 to +55 °C
-25 to +70 °C
Storage and transport with
standard works packing
12 Humidity
Standards IEC 60068-2-3
Permissible humidity Annual average 75 % relative
It is recommended to arrange the humidity; on 30 days in the year
units in such a way that they are up to 95 % relative humidity;
13 not exposed to direct sunlight or
pronounced temperature changes
condensation not permissible!
14
15
9/14 Siemens SIP · Edition No. 7
Busbar Differential Protection / 7SS60
Selection and ordering data
Rated current/frequency
7SS601 - A 0-0AA0
1
100 mA; 50/60 Hz AC 0
100 mA; 16.7 Hz AC 6
48 to 60 V DC
110 to 125 V DC
3
4
6
220 to 250 V DC 5
10
11
12
13
14
15
Siemens SIP · Edition No. 7 9/15
Busbar Differential Protection / 7SS60
Selection and ordering data
Connector adapter
Test adapter
W73078-Z9005-A710
7XV6010-0AA00
7 Matching transformer
1 A, 50/60 Hz 4AM5120-1DA00-0AN2
5 A, 50/60 Hz 4AM5120-2DA00-0AN2
1 A, 5 A, 50/60 Hz 4AM5272-3AA00-0AN2
8 Manual 7SS60
English E50417-G1176-C132-A3
10
11
12
13
14
15
9/16 Siemens SIP · Edition No. 7
Busbar Differential Protection / 7SS60
Connection diagrams
Connection diagrams
6
Fig. 9/14 Connection diagram for 7SS601
10
11
12
13
14
Fig. 9/15 Connection diagram for 7TM700 Fig. 9/16 Connection diagram for 7TS720 15
Siemens SIP · Edition No. 7 9/17
Busbar Differential Protection / 7SS60
Connection diagram
10
11
12
13
14