SECTION-AA
NOTES
1. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED.
2. FOR NON—PRESSURIZED TANKS OF DIAMETER =< 10 METER, ANCHOR CHAIR SHALL BE PROVIDED AS
PER THIS STANDARD. IF REQUIRED BY DESIGN, ANCHOR CHAIR SHALL BE AS PER 7-12-0004.
3. NO. OF ANCHOR CHAIRS SHALL BE MULTIPLE OF FOUR AND STRADDLE NORTH SOUTH CENTRE LINE.
4. FOR MATERIAL SPECIFICATION REFER ENGINEERING DRAWING.
5. IN CASE OF CONFLICT ENGINEERING DRAWING SHALL GOVERN.
6. ANCHOR CHAIR DESIGN SHALL BE CHECKED FOR PRESSURIZED TANKS AS PER THE PROVISIONS OF
DESIGN CODE.
7. SUITABLE B.C.D. AND SLOTTED HOLES ON TOP PLATE SHALL BE SELECTED FOR STRESS RELIEVED
TANKS TO TAKE CARE OF THERMAL EXPANSION.