Alticom Case Study

Alticom bv is a Dutch company that owns 33 transmission


Power+ RM
masts in The Netherlands. Alticom purchased Gamatronic
Power+ RM systems with matching battery cabinets in order Power+RM is a complete, end to end 19” 10-100 kVA rack-
to equip their full solution data center rooms. mount solution.

• Double conversion power provides complete, consistent and


clean AC output to the data center power bus.
Customer Profile • The power+ operates at a super high efficiency of 96%, resulting
in less heat and lower cooling costs.
Alticom rents out space in their 33 transmission masts for • True online battery is galvanically connected to the rectifier and
antennas to Telecommunication network operators and inverter on a common DC link for increased reliability.
room within the constructions for the associated equipment
• Hot plug, hot swap system, enables modules and controller
and as colocation/data center replaced or added without interrupting the output power or
transferring to bypass.

• Compact , lightweight power modules are only 2 U and 9kg each.


The Challenge • High density aesthetics, as well as usability. Available in uniform
& modern cabinets, integrating seamlessly with existing data
Alticom rents out entire floors in the towers to Telecom com- center design. Alternately, Power+ RM components can be easily
panies. Some choose to bring all the equipment (including housed in existing racks.

the UPS) while others request full solutions from Alticom. • The Gamatronic Power+ UPS system employs a single unit form
factor that conserves precious data center floor space. The prod-
uct’s lightweight, user friendly, 10 kVA modules provide simple,

The solution reliable, low cost expansion to meet growing power needs.
Because the Power+ is modular and scalable, conservation of
capital is achieved by investing only when capacity is needed.
Alticom decided to provide their full solution room with P+
• Scalability from 10kVA to 100kVA enables UPS to grow in 10kVA
RM 100 KVA and RM Battery cabinet 2*64 20 Ah. steps with expanding needs.

At the end of the process 33 transmission masts will be • Cost effective N+1 redundancy, ensures that the load will con-
equipped with the Gamatronic Power+ RM-100KVA with tinue to be supported even if a module fails.
Matching RM-Battery-Cabinet. • Highest AC to AC efficiency rating of 96% results in lower energy

The improved PUE (power-efficiency) of these rooms is costs and reduced heat.

better than 1.1, thanks to the efficient cooling and UPS • System controller provides advanced management and control
performance. functions, including internet, TCP/IP and SNMP communications
standard. UPS operation is independent of controller function.

• UPS, battery and maintenance bypass switch are mounted in 19”


x 42U racks for easy installation.