You are on page 1of 2

Metalogic Inspection Services Inc

4518-101 Street
Edmonton, AB T6E5G9
T: 469-6161, F: 469-6152

Phased Array Practical Exam


Final Mark Breakdown Student Name:

Probe Configuration

Sectoral Scan
- 45º-70º
- Utilize as many channels as unit allows
- .5º Resolution

Marks /10

Linear Scan
- 60º
- 8 elements per beam, create as many beams as possible

Marks /10

Calibration

Using a side drilled hole calibrate sensitivity, wedge delay and a 2 point TCG for the Sectoral Scan
only.

Marks /30

Calibrate encoder

Marks /5

Scanning Parameters (Weld is to be examined with Sectoral Scan only)

- Set up all relevant position parameters and measurements for examining a weld (assume
dual probe set up)
- 1mm scan resolution
- A, S, C views

Marks /15
Save setup on Jump Drive as your name/probe/wedge

Create an encoded scan of the entire length of the weld coupon.

Report

Create a report containing:

- All probe and setup parameters /2.5


- Defect image with proper cursor and gate locations /5
- Defect measurements (%Amplitude, Height, Depth, Scan start location, Length, Axial
distance to centerline /5
- User fields containing Contractor, Technician, Customer, Project and Part Number /5
- Defect interpretation in a comment /2.5

Marks /20

Report is to be saved as name/plate number and printed for review

Defect Accuracy Measurement Marks /10

Practical Exam Final Mark /100

Student Name

Date

Instructor

You might also like