You are on page 1of 1

Ref.

: KIOS–NDT–WP–01

RIGHT ANSWER SHEET:

Question Paper No. : PT / Level 2 / G / 002


METHOD : PT EXAMINATION: General
LEVEL : II TOTAL MARKS : 40

1. D. The type of flaws to be found. 25. D. any of the above.


2. D. Indications 26. C. is to be done as soon as after completion of
3. A. Flammable materials examination.
4. D. Removal of excess Penetrant was inadequate. 27. A. High viscosity.
5. C. both A & B. 28. B. Penetrant should be applied uniformly.
6. C. To be carried out any time after minimum 29. C. Pre-clean, Penetrant application, emulsifier
Penetrant dwell time is over, provided Penetrant application, excess Penetrant removal, drying,
remains wet on surface being examined. developer application, inspection, post clean for
7. B. Emulsifier post emulsified method using aqueous wet
8. D. Any of the above. developer on a stainless steel weld.
9. B. Discontinuity is having greater depth. 30. D. all of the above.
10. D. None of the above. 31. C. determines relevance, measure the size and
11. D. all of the above. spacing, determine if linear, and determine
12. A. Rust. acceptability.
13. D. all of the above. 32. D. Good to detect wide and shallow discontinuities.
14. C. a post-cleaner is the same as pre-cleaner. 33. B. not essential for all materials.
15. B. Post emulsified. 34. D. Use a hose and nozzle with forceful droplets.
16. B. Post emulsified. 35. A. Smooth, narrow, straight lines.
17. D. Depends on the contaminant and the metal. 36. D. all of the above.
18. D. Penetrant not subject to water contamination. 37. C. applied by brush.
19. C. Surface condition and configuration of test item. 38. B. Penetrant methods include materials which can
20. C. Excessive rough surface. cause dermatitis if proper precautions are not
21. B. acidic. observed.
22. D. all of the above. 39. A. Water-washable.
23. C. Solvent removable. 40. D. Dry the part.
24. A. Non-aqueous Wet developer.

Question Paper No. : PT / Level 2 / S / 002


METHOD : PT EXAMINATION: Specific
LEVEL : II TOTAL MARKS : 20

1. D. 500C ~ 560C. 11. B. 10 to 30 minutes after the application of developer


2. B. Use of solvent removable dye penetrants. 12. B. Adopt a new procedure but require
3. D. 10 minutes minimum re-qualification.
4. D. None of the above. 13. C. 5 minutes for both.
5. A. Normal evaporation. 14. A. Not acceptable.
6. C. Wipe with dry lint free cloth followed by cloth 15. C. Relevant linear indication.
damped with cleaner. 16. A. To be examined by any suitable methods to ensure
7. A. 1.0 % defect has been removed.
8. A. 1000 w/cm2. 17. C. It can be accepted after confirmation that
9. B. Surface preparation. no
10. B. At least one inch unacceptable imperfection is present by the use of
other NDT methods.
18. D. Above B & C.
19. B. Acceptable.
20. B. It is a rounded indication and acceptable.

________
S.B.Mody
LEVEL III EXAMINER
(NAME & SIGNATURE)