CHỈ DẪN KỸ THUẬT HT CẤP NƯỚC - TIẾNG ANH
CHỈ DẪN KỸ THUẬT HT CẤP NƯỚC - TIẾNG ANH
All valves must be ensured to be lubricated, with the lowest pressure loss
when they are fully open and fully watertight when they are closed.
All valves are closed in the clockwise direction.
Valve body shall be subjected to hydraulic test of the manufacturer at
twice working pressure of the valve.
(3) Check valve and returned valve
Manufactured as standards: Din F4, BS 5163, JIS. Working pressure:
10bar.
(4) Air-relief valve
1.1.6.1 Overview
When installing the external drainage system, required minimum depth of
buried culvert must be h=0.4m from the finished ground to top of culvert.
Underground pipe must be properly installed in accordance with standards.
System of ceiling-hanged pipes must be fixed by steel rods. Pipes must be
surely installed with slope for good drainage.
Distance between transmission lines and piping systems vertically and
horizontally must be as Vietnam Standard.