You are on page 1of 2

RS232 cable

1. RS232 cable

1.1 B&R online cable

This cable can be used for connecting the CPU with the device used for programming (PC).

Model number Short description


0G0001.00-090 Cable PC - PLC/PW, RS232, online cable

Dimensions

2500

Programming device
(PC)

Controller

Pin assignments
9-pin DSUB socket 9-pin DSUB socket

RXD 2 3 TXD
TXD 3 2 RXD
9 5 GND 5 5 GND 9 5
DTR 4 4 DTR
6 1 DSR 6 6 DSR 6 1
RTS 7 8 CTS
CTS 8 7 RTS

Data sheet V 1.00 1


RS232 cable

1.2 Standard RS232 cable

A standard RS232 cable can be used as online cable for the following B&R system CPUs,
among other things:

• System 2003
• System 2005
• System 2010

Pin assignments
9-pin DSUB socket 9-pin DSUB socket

Programming device Controller


(PC) (CPU)
9 5 9 5

RXD 2 3 TXD
6 1 6 1
TXD 3 2 RXD
GND 5 5 GND

1.3 X20 CPUs

On X20 CPUs, the RS232 interface is located on the supply module. The open wires of the
RS232 cable are connected to the corresponding terminals. An attachment cable must be
assembled according to the diagram below.

Pin assignments
9-pin DSUB socket 12-pin terminal block

r e
SI

Programming device Controller


(PC) (X20 CPU) TXD RXD
9 5
GND
RXD 2 TXD
6 1 TXD 3 RXD
GND 5 GND

2 Data sheet V 1.00