Chemical fixings
The performance class amongst dynamic anchors
VERSIONS APPROVALS
▪ zinc-plated steel
▪ high corrosion resistant steel
BUILDING MATERIALS
Approved for:
▪ Concrete C20/25 to C50/60,
cracked and non-cracked
http://www.fischer.de/en/ - 16/06/2013 1
Highbond anchor dynamic FHB-A dyn
Chemical fixings
TECHNICAL DATA
galvanized
Drill hole diameter Drill depth through Anchorage depth Anchorage depth
fixture
do h0 hef hef
Article name Art.-No. [mm] [mm] [mm] [mm]
FHB-A dyn 12 x 100/25 092018 ● 14 130 100
FHB-A dyn 12 x 100/50 092019 ● 14 155 100
FHB-A dyn 16 x 125/25 092020 ● 18 155 125
FHB-A dyn 16 x 125/50 092036 ● 18 180 125
FHB-A dyn 20 x 170/50 092037 ● 24 225 170
FHB-A dyn 24 x 220/50 092038 ● 28 275 220
highly corrosion-resistant
Drill hole diameter Drill depth through Anchorage depth Anchorage depth
fixture
do h0 hef hef
Article name Art.-No. [mm] [mm] [mm] [mm]
FHB-A dyn 16 x 125/50 C 093445 ● 18 180 125
http://www.fischer.de/en/ - 16/06/2013 2
2 FIS HB 345 S 502290 ▯ RUS, LT, LV, EST, UA, KZ 1 cartridge 360 ml, 2 x static mixer FIS S 6
FIS HB 345 S 502913 ▯ D, GB, DK, S, FIN, N 1 cartridge 360 ml, 2 x static mixer FIS S 6
Highbond anchor dynamic FHB-A dyn
FIS HB 150 C 077529 ▯ D, GB, F, E, NL, CZ 1 cartridge 145 ml, 2 x static mixer FIS S 6
FIS S 061223 — — 10 static mixer 10
Chemical fixings
Cartridge temperature Gelling time Temperature Curing time
FIS HB FIS HB at anchoring base
(minimum + 5°C) FIS HB
‒ 5°C – ± 0°C 360 min.
± 0°C – + 5°C 180 min.
+ 5°C – +20°C 15 min. + 5°C – +20°C 90 min.
+20°C – +30°C 6 min. +20°C – +30°C 35 min.
+30°C – +40°C 4 min. +30°C – +40°C 20 min.
> +40°C 2 min. > +40°C 12 min.
Please note: The curing times apply for dry anchoring bases, in damp anchoring bases they should be doubled. Remove water from drill hole.
FILLING QUANTITIES
Type Mortar volume in scale units Anchors per cartridge FIS HB 345 S *)
shown on the cartridge labels‘ corresponding scale
130
http://www.fischer.de/en/ - 16/06/2013 3
Compressed-air cleaning gun
Fits Sales unit
Highbond
Item anchorArt.-No.dynamic FHB-A dyn [pcs]
Compressed-air cleaning gun ABP 059456 FHB-A dyn M20-M24 1
LOADS
Chemical fixings
Highbond anchor dynamic FHB dyn
Highest permissible loads for a single anchor1) 6) in concrete B25 resp. C20/254).
For the design the complete approval Z-21.3-1748 has to be considered.
Cracked or Non-cracked concrete
Type Effective Min. member Installation Permissible Permissible Min. Min.
anchorage depth thickness torque tensile load shear load spacing edge distance
hef
[mm]
hmin
[mm]
Tinst
[Nm]
∆Nzul3)
[kN]
∆Vzul3)
[kN]
smin2)
[mm]
cmin2)
[mm]
2
FHB dyn 12x100 100 200 40,0 14,1 6,7 100 100
FHB dyn 12x100 V 105 200 40,0 14,1 9,6 100 100
FHB dyn 16x125 125 250 60,0 23,0 11,9 100 100
FHB dyn 16x125 V 130 250 60,0 23,0 17,0 100 100
FHB dyn 16x125 C 5) 125 250 60,0 15,6 11,9 100 100
FHB dyn 20x170 170 340 100,0 28,1 17,0 150 150
FHB dyn 24x220 220 440 120,0 28,9 22,2 180 180
1)
The permissible loads apply for the design method II (unknown lowest load and unknown load 3)
For combinations of tensile loads, shear loads as well as reduced edge distances or spacings
cycles). The partial safety factor for material resistance and the partial safety factor for action (anchor groups) see approval.
regarding fatigue as regulated in the approval are considered. When using design method I higher 4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
permissible loads may be possible. As an single anchor counts e.g. an anchor with a spacing s ≥ 5)
Anchor rod FHB-A dyn-C made of highly corrosion-resistant steel of the corrosion resistance class
3 x hef and an edge distance c ≥ 1,5 x hef. Accurate data see approval. IV e.g. 1.4529
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. 6)
The given loads are valid for fixations in dry and humid concrete for temperatures in the substrate
up to +50°C (resp. short term up to 80°C) and best possible drillhole cleaning according approval.
131
http://www.fischer.de/en/ - 16/06/2013 4
Highbond anchor dynamic FHB-A dyn V
Chemical fixings
The performance class amongst dynamic anchors
http://www.fischer.de/en/ - 16/06/2013 1
Highbond anchor dynamic FHB-A dyn V
TECHNICAL DATA
Chemical fixings
Highbond anchor dynamic FHB-A dyn
V
http://www.fischer.de/en/ - 16/06/2013 2
2 FIS HB 345 S 502290 ▯ RUS, LT, LV, EST, UA, KZ 1 cartridge 360 ml, 2 x static mixer FIS S 6
FIS HB 345 S 502913 ▯ D, GB, DK, S, FIN, N 1 cartridge 360 ml, 2 x static mixer FIS S 6
Highbond anchor dynamic FHB-A dyn V
FIS HB 150 C 077529 ▯ D, GB, F, E, NL, CZ 1 cartridge 145 ml, 2 x static mixer FIS S 6
FIS S 061223 — — 10 static mixer 10
Chemical fixings
Cartridge temperature Gelling time Temperature Curing time
FIS HB FIS HB at anchoring base
(minimum + 5°C) FIS HB
‒ 5°C – ± 0°C 360 min.
± 0°C – + 5°C 180 min.
+ 5°C – +20°C 15 min. + 5°C – +20°C 90 min.
+20°C – +30°C 6 min. +20°C – +30°C 35 min.
+30°C – +40°C 4 min. +30°C – +40°C 20 min.
> +40°C 2 min. > +40°C 12 min.
Please note: The curing times apply for dry anchoring bases, in damp anchoring bases they should be doubled. Remove water from drill hole.
FILLING QUANTITIES
Type Mortar volume in scale units Anchors per cartridge FIS HB 345 S *)
shown on the cartridge labels‘ corresponding scale
130
http://www.fischer.de/en/ - 16/06/2013 3
Compressed-air cleaning gun
Fits Sales unit
Highbond
Item anchorArt.-No.dynamic FHB-A dyn V [pcs]
Compressed-air cleaning gun ABP 059456 FHB-A dyn M20-M24 1
LOADS
Chemical fixings
Highbond anchor dynamic FHB dyn
Highest permissible loads for a single anchor1) 6) in concrete B25 resp. C20/254).
For the design the complete approval Z-21.3-1748 has to be considered.
Cracked or Non-cracked concrete
Type Effective Min. member Installation Permissible Permissible Min. Min.
anchorage depth thickness torque tensile load shear load spacing edge distance
hef
[mm]
hmin
[mm]
Tinst
[Nm]
∆Nzul3)
[kN]
∆Vzul3)
[kN]
smin2)
[mm]
cmin2)
[mm]
2
FHB dyn 12x100 100 200 40,0 14,1 6,7 100 100
FHB dyn 12x100 V 105 200 40,0 14,1 9,6 100 100
FHB dyn 16x125 125 250 60,0 23,0 11,9 100 100
FHB dyn 16x125 V 130 250 60,0 23,0 17,0 100 100
FHB dyn 16x125 C 5) 125 250 60,0 15,6 11,9 100 100
FHB dyn 20x170 170 340 100,0 28,1 17,0 150 150
FHB dyn 24x220 220 440 120,0 28,9 22,2 180 180
1)
The permissible loads apply for the design method II (unknown lowest load and unknown load 3)
For combinations of tensile loads, shear loads as well as reduced edge distances or spacings
cycles). The partial safety factor for material resistance and the partial safety factor for action (anchor groups) see approval.
regarding fatigue as regulated in the approval are considered. When using design method I higher 4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
permissible loads may be possible. As an single anchor counts e.g. an anchor with a spacing s ≥ 5)
Anchor rod FHB-A dyn-C made of highly corrosion-resistant steel of the corrosion resistance class
3 x hef and an edge distance c ≥ 1,5 x hef. Accurate data see approval. IV e.g. 1.4529
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. 6)
The given loads are valid for fixations in dry and humid concrete for temperatures in the substrate
up to +50°C (resp. short term up to 80°C) and best possible drillhole cleaning according approval.
131
http://www.fischer.de/en/ - 16/06/2013 4