You are on page 1of 6
5. Application and Handling The broadly diversified areas of usage of Heradesign products are not an end in itself. The central idea is the tangible use, which these highly-effective acoustic ceiling and wall solutions offer, each according to the structural and technical demands of the plan. Precise handling guidelines as well as detailed recommendations for transport and storage give your HefadeSign. product selection optimal security. 5.01 Application and Handling Durability of Magnesite Bound Acoustic Panels Medium, Area of Attack Behaviour 1) Water and water vapour | Not resistant to direct, long-term effects of water (rain, condensation, moisture from soll, capil action). This results in the panels swelling as well as reduced mechanical stability and efflorescence of ‘magnesium sulphate. Likewise, permanent exposure to water vapour (rel. air humidity > 90%) leads to ‘swelling and a reduction of mechanical stability. 2) Organic solvents* ‘Contact with organic solvents in a liquid form (local exposures or spots) causes them to be party (e.g, acetone, alcohol, ether, absorbed by the panel and released as vapour. No adverse effects to the mechanical stability of the Petrol, benzol, halogenated | panels has been observed (except for flammability after exposure to flammable solvents, as well as di hydrocarbons, ols etc.) | tying the visible surface) Solvent vapours in concentrations that are allowed by hygienic regulations for the workplace, have no effect on the building biological properties of the magnesite bound Heradesign acoustic panels according to findings so far. SV Acids and alkalis 'a) Acids: ‘Magnesite bound Heradesign acoustic panels are not resistant to the direct effects of acids Depending on the concentration and strength of the acid, direct contact to an acid wil ‘cause localised dissolving of the bonding agent in the panel. Generally, harmiess salts are formed (party with a violent reaction). In some cases acid vapours occur, which are within the workplace hygienic regulations (e.g. common in chemical laboratories or similar facii- ties), and which do not damage the products. ) Alkalis: The effect of alkalis on the panels causes the bonding agent to soften and Is comparable to the effects of water, W Paint ‘The surface of magnesite bound Heradesign acoustic panels can be Weated with commercial pant based on polyvinyl acetate, or acrylics, silicates, distempers, etc. The type of paint that is already on the surface must be taken into consideration. 7) Cuestors about eopcatins repaing contact fo spate sohes/ohent Iroduoa/ er expaure fo gh concertos of scr must be dacined ech wth Hath chen er sence Application Overview For stone wool and magnesite bound wood wool panels for acoustic ceiling and wall coverings by Heraklith. Fields of Daily application | Climate *) assembly and [T 12-30°C storage conditions | ch. max. 75 % Products Herakustik star Herakustk F Herakustk IP Travertin micro Element Herakustik star 25/MW | Element Herakustik F 25/MW Element Travertin micro 25/MW | Type of standard paint 5.02.1 ‘Construction Application and Handling Note ‘Observe storage ‘and installation information Ti2- 22°C 1h. 30 - 75.96 buildings and air- ports train stations Herakustik star Herakustik F Travertin micro All constructions No restrictions: Gymnasiums 112-22 Sports halls eh, 40 80 % Herakustk star Herakustk F “Travertin micro Siicate Dasign that is safe ‘against ball throwing DIN 18032 PS: as ‘of a room height of 55m" Tee arenas T5- 150 ch. 60 - 90 9% Herakustik F Travertin micro “Slicate with BFA additive Back ventilation screw mounted ‘Do not place above the ice surface Indoor swimming [722-28 °C pools th. 40 - 80 % Herakustik star Herakustik F “Travertin micro. Silicate with BFA additive insertion mount- ing with visible profiles ‘Air conditioner back ventilation for panels, Ti2-30°C rth, 40 - 80 % + sale against ball throwing Herakustik star Herakustik F Travertin micro Silicate with BFA additive screw mounted insertion mount= ing with visible profiles Systems that are safe against ball towing are ones thal can withstand the strain from bale or rom signifeant changes substructure, CCertiication bases: DIN 18032, Part 3, certification of satety against bal throwing ‘Te demands thet DIN places on salty against ball throwing always refers to the enti construction, substructu Min, panel thickness, is 25 mm, Use very corrosion protected substruc- tures and fasteners. ‘Screw mounting ‘only on wooden laths. to the elements and their which means the cladding elements and the For celing systems, safety again bal rowing according to OIN 18032 Pars only spplicabe as ofa clearance of 5.5 metres. The bal throwing tests are based on tis clearance and can't be applied to lower clearances. 5.02.2 Application and Handling Application Overview For stone wool and magnesite bound wood wool panels for acoustic ceiling and wall coverings by Heraklith. Field of pplication Products Type of, ‘Construction J standard paint [Shooting ranges [1 12-20°C | Herakustik star ‘All constructions rch. 40 - 80% _| Herakustik F Bowing alleys |T12-20°C | Herakustk star All constructions rh. 40-80% | Herakustik F Travertin micro. fWorkshops and __|T12-20°C | Herakustik F ‘All constructions industrial buildings |rh. 30 - 80% | Travertin micro Herakustk IP Element Herakustk star 25/MW| Underground car Element Herakustik F 25/MW = Insertion park 212)5) Element Travertin micro 25/MW. ‘mounting, [Car park decks ®95|T5-20°C | Herakustik star Silicate with BFA | =-screw mounting | Mechanical th. 40-80% | Herakustik F additive =doweled Ventilation for Travertin micro depending on type | doweled mounting Herakustik IP of panel the comers of the Element Herakustik star 25/MW| panels must be Element Herakustk F 25/MW Insertion held by dowels Element Travertin micro 25/MW ‘mounting, T5-20°C | Herakustik star Silicate with BFA | =screw mounting | Back ventilation th. 60-909 | Herakustik F additive onto profiles | for ceiling, provide Element Herakustk star 25/MW Insertion mechanical Element Herakustk F 25/MW. mounting ventilation Wine cellars, Bottle |T12- 22 Herakustik star Silicate with BFA |—=screw mounting | Back ventilation filing halls rh. 60 - 80°C | Herakustik F additive Tavertin micro. Interior appications | 20- 30°C | Herakustik star Slicate with BFA | All constructions jn tropical climate |rh. 60 - 80% | Herakustik F additive zones Travertin micro. ‘Commercially used = = humid rooms, large kitchens, clean rooms (dust and/or germ free), paint shops, slaughterhouses, ‘cooling rooms 5.02.3 Application and Handling Field of Daily Glimate Type of Construct application standard paint ‘Sports buildings, | Continental Herakustik star‘ Silicate All constructions | Panels must not be shooting ranges, | rh. 40 - 80.% Herakustik F directly exposed to open halls, Travertin micro K-09 and VK-10 | the weather loggias Wartime Herakustik star | Siicate with BFA | not recommended rth, 80 - 85 % Herakustik F additive Travertin micro Hot and humid |Herakustik star | Silicate with BFA th. 60 - 90 % Herakustik F additive Travertin micro Hot and ory Herakustik star | Slicata with BFA Herakustik F additive Travertin micro ‘Sound protection Not suitable, or walls, cladding for contact applications tunnels, bridges, ‘group underground passages 1) Observe tre protection requirement, ‘You can get your Installation guidelines and product data shoets for 2) Busing set ar umsty up to 5%, vebaton and hurt removed erasesign sodustc panel rom you dealer cr cect om Herat trust be guaranteed cut thie time frat eas poking comers} ‘osera assembly condos! 3) Pay attention to the dew point temperature of the surrounding furtaes, 4) The maximum vats forthe day ax 15% above the average valve {forthe day) must not be mantined constant Ths panels mist be se fo dry out agaln nthe dy periods (aunmer or wits) 5.03.1 Application and Handling Field of Application For magnesite bound Heradesign acoustic cei and wall coverings in interior areas Herakustik star, Herakustik F, Herakustik IP, Travertin micro CM recy ae | Relative air humidity (» 56 8 10 12 14 16 18 20 22 24 2 2 30 32 (C% Temperature (max. 12h daily average) — Application limit — — — Area limit @ ‘dea\, all constructions and products ® Condensation range, only specific construc- tions, all products with additional equipment ~ @ Dry range, all products, only specific constructional consultation required construction @ Humid range, only specific constructions and products with additional equipment ~ construc- tional consultation required

You might also like