SPECIFICATIONS FOR REGULATED DC POWER SUPPLY

(Specification for 0-40 V/0-50A DC Power supply)

Input: 230 V AC,+/- 10%, 50 Hz,

Single phase.

Output Voltage: 0 – 40 V DC continuously variable through

coarse and fine potentiometers.

Load current: 0 – 50 Amps (with seettable limit from 0.2 A to

52 Amps max. thorough Coarse and Fine

Potentiometers

Line Regulation: +/- 0.015 % of max output voltge or

better for variation in input voltage.

Load Regulation: +/- 0.015 % of max output voltage or better for

variations load current.

Ripple: Less than 2 mV rms or 10 mV peak to peak.

Protections: a) Fuse protection is provided at AC Input.

b) Unit Output is protected against overloads

and short circuits.

c) Miniature Circuit Breaker is provided at AC

Input.

Controls: a) ON/OFF Circuit Breaker at AC Input


b) Coarse and Fine Voltage set potentiometers

on front panel.

c) Coarse and Fine Current set potentiometers

on front panel.

Indications: a) LED indications for AC Input , CV and CC

Mode of operations.

b) 3 ½ Digit Panel Meters for Output voltage

and load current on front panel.

Termination: a) Input is given through barrier terminal block

on rear panel.

b)output remote sense terminals

are brought on to barrier terminal

block. Output is brought on to

strudy screw and nut terminals on rear panel.

and also on to binding terminals ( 25 Amps

capacity) on front panel,

Mechanical: The unit t is designed suitable with 19” Rack with

following approximated dimensions

482 mm (19”) width x 222 mm Height ( 5 U) x 470 mm Depth ( 18.5 “)

Efficiency: Better than 55%.

Mode of operation: Linear Control CV/CC with Traic pre regulator.

Operating Temp. 0 to + 50 º C,

Cooling: Forced air cooling with Internal exhaust fan

Warranty: One year from the date of acceptance at the site.


SPECIFICATIONS FOR REGULATED DC POWER SUPPLY

(Specification for 5 Volt,60A DC Power supply)


Input: 230 V AC,+/- 10%, 50 Hz,

Single phase.

Output: 5 V DC 60 Amps.

Output variation: 4.5 V to 5.5 V DC through Front panel

potentiometer.

Line Regulation: +/- 0.015 % of max output voltge or

better for variation in input voltage.

Load Regulation: +/- 0.015 % of max output voltage or better for

variations in load current.

Ripple: Less than 10 mV peak to peak.

Protections: a) Fuse protection is provided at AC Input.

b) Unit Output is protected against overloads

and short circuits.

c) Miniature Circuit Breaker is provided at AC

Input.

Controls: a) ON/OFF Circuit Breaker at AC Input

b) One Voltage set potentiometer to set the

Output voltage from 4.5 V to 5.5 V DC

on front panel.

c) One Current set potentiometer to set the


Current limit from 0.1 A to 66 Amps
on front panel.

Indications: a) LED indications for AC Input , CV and CC

Mode of operations.

b) 3 ½ Digit Panel Meters for Output voltage

and load current on front panel.

Termination: a) Input is given through barrier terminal block

on rear panel.

b)output remote sense terminals

are brought on to barrier terminal

block. Output is brought on to

strudy screw and nut terminals on rear panel.

Regulation measurement at sense points.

Mechanical: The unit t is designed suitable with 19” Rack.

Mounting with following approximate dimensions

482 mm Width x 550 mm Depth x 177 mm Height

Mode of operation: Linear Control CV/CC with Traic pre regulator.

Operating Temp. 0 to + 50 º C,

Cooling: Forced air cooling with Internal exhaust fan

Warranty: One year from the date of acceptance at the site.