You are on page 1of 377

ACI 318-19

Changes to the Concrete


Design Standard

WWW.CONCRETE.ORG/ACI318 1
Learning Objectives

1. Understand where higher grades of


reinforcement are accepted and changes to
the requirements for structural concrete to
allow the higher reinforcement grades,
including development lengths and phi-
factors.
2. Identify the added requirements to address
shotcrete as a concrete placement method.
3. Explain the expanded scope of deep
foundation provisions, including seismic
requirements.

WWW.CONCRETE.ORG/ACI318 2
Learning Objectives

4. Learn the new requirements for post-


installed screw type anchors and shear lug
design for anchoring to concrete.
5. Describe the changes to shear design
provisions and equations.
6. Identify new tension longitudinal
reinforcement requirements in special
structural walls

WWW.CONCRETE.ORG/ACI318 3
Speakers

Speaker bios are included in your handouts for


the presentation

WWW.CONCRETE.ORG/ACI318 4
ACI 318-19
Changes to the Concrete
Design Standard

Introduction

WWW.CONCRETE.ORG/ACI318 5
Today’s Seminar

• Major changes
• Grouped by topic

• Organization • Foundations
• Existing structures • Anchorage to
• Loads & analysis concrete
• Slabs • Seismic
• Post-tensioning
• Precast/Prestressed
• Circular sections
• Walls

WWW.CONCRETE.ORG/ACI318 6
Today’s Seminar

• Major changes
• Grouped by topic

• High-strength • Durability and


reinforcement materials
• Development length • Strut-and-tie
• Shear modifications method
• Shotcrete
• Appendix A

WWW.CONCRETE.ORG/ACI318 7
Today’s Seminar

• Changes from ACI 318M-14 to ACI 318-19

318M-14 318-19

WWW.CONCRETE.ORG/ACI318 8
Why Do We Change ACI 318?

• Reflects new research


• Construction practices change
• Sometimes tragic events provide introspect
– Earthquakes or other natural disasters
– Collapses or construction accidents
– Observed in-service performance
• New materials
– Or better ways of making established materials
• More powerful analytical tools

WWW.CONCRETE.ORG/ACI318 9
Resources

• ACI 318

• Speaker notes

• ACI Reinforced Concrete Design Handbook

• ACI 318 Building Code Portal

WWW.CONCRETE.ORG/ACI318 10
ACI 318-19

Variety of formats, including:


• Printed copy
– Softcover and hardcover
• Enhanced PDF

Versions
• English
• Spanish
• In.-lb units
• SI units

WWW.CONCRETE.ORG/ACI318 11
Speaker Notes

Today’s presentation

WWW.CONCRETE.ORG/ACI318 12
ACI Design Handbook
• 15 chapters

• Explanatory text

• Design aids

• 2019 version
expected early next
year

WWW.CONCRETE.ORG/ACI318 13
ACI Design Handbook

• 1: Building Systems • 9: Columns


• 2: Structural Systems • 10: Walls
• 3: Structural Analysis • 11: Foundations
• 4: Durability • 12: Retaining Walls
• 5: One-Way Slabs • 13: Serviceability
• 6: Two-Way Slabs • 14: Strut-and-Tie
• 7: Beams • 15: Anchorage
• 8: Diaphragms

WWW.CONCRETE.ORG/ACI318 14
ACI 318 Building Code Portal

WWW.CONCRETE.ORG/ACI318 15
ACI 318-19
Changes to the Concrete
Design Standard

Organization

WWW.CONCRETE.ORG/ACI318 16
Major goals of ACI 318 organization

• Ease of use
• Find the information you need quickly
– Consistent organization
– Organized in the order of design
• Increase certainty that a design fully meets
the Code
– A chapter for each member type
– All member design provisions in one chapter

WWW.CONCRETE.ORG/ACI318 17
Navigation

10 Parts
• General

WWW.CONCRETE.ORG/ACI318 18
Navigation

10 Parts
• General
• Loads & Analysis

WWW.CONCRETE.ORG/ACI318 19
ACI 318 Style

WWW.CONCRETE.ORG/ACI318 20
Navigation

10 Parts
• General • Materials &
• Loads & Analysis Durability
• Members • Strength &
• Joints/Connections/ Serviceability
Anchors • Reinforcement
• Seismic • Construction
• Evaluation

WWW.CONCRETE.ORG/ACI318 21
Part 1: General

• 1: General

• 2: Notation and Terminology


– dagg = nominal maximum size of coarse
aggregate, mm
– aggregate—granular material, such as sand,
gravel, crushed stone, iron blast-furnace slag, or
recycled aggregates including crushed hydraulic
cement concrete, used with a cementing
medium to form concrete or mortar.

WWW.CONCRETE.ORG/ACI318 22
Part 1: General

• 3: Referenced Standards
Materials
Design
Inspection loads

Precast/
Load paths
Prestressed

• 4: Structural System
Requirements Fire Structural
Safety analysis

Structural Strength
integrity

Serviceability
Sustainability
Durability

WWW.CONCRETE.ORG/ACI318 23
Part 2: Loads & Analysis

• 5: Loads

• 6: Structural Analysis
– Simplified, first-order, second-order
– Linear, nonlinear
– Slenderness
– Materials and section properties

WWW.CONCRETE.ORG/ACI318 24
Part 3: Members

• 7: One-Way Slabs • 11: Walls

• 8: Two-Way Slabs • 12: Diaphragms

• 9: Beams • 13: Foundations

• 10: Columns • 14: Plain Concrete

WWW.CONCRETE.ORG/ACI318 25
Typical member chapter sections

• X.1 Scope
• X.2 General
• X.3 Design Limits
• X.4 Required Strength
• X.5 Design Strength
• X.6 Reinforcement Limits
• X.7 Reinforcement Detailing
• X.? ?

WWW.CONCRETE.ORG/ACI318 26
ACI 318-19
Organization
Anchorage, Ch. 9
12

Flexure, Ch. 9
10

Δ
Shear, Ch. 9
11

Deflection, Ch. 9

WWW.CONCRETE.ORG/ACI318 27
Part 4: Joints / Connections / Anchors

• 15: Beam-column and


slab-column joints

• 16: Connections
between members

• 17: Anchoring to
concrete

WWW.CONCRETE.ORG/ACI318 28
Part 5: Seismic

• 18: Earthquake
Resistant Structures

WWW.CONCRETE.ORG/ACI318 29
Part 6: Materials & Durability

• 19: Concrete: Design and Durability


Properties

(Credit: PCA)
• 20: Steel Reinforcement Properties,
Durability, and Embedments

WWW.CONCRETE.ORG/ACI318 30
Part 7: Strength & Serviceability

• 21: Strength Reduction Factors 𝜙

• 22: Sectional Strength

WWW.CONCRETE.ORG/ACI318 31
Organization
Member Chapter Toolbox Chapter
9.5 — Design strength
9.5.2 — Moment
9.5.2.1 — If Pu < 0.10f’cAg, 22.3 —Flexural strength…
Mn shall be calculated in
accordance with 22.3. 22.3.3.4 …

9.5.2.2 — If Pu ≥ 0.10f’cAg, 22.4 — Axial strength or


Mn shall be calculated in combined flexural and axial
accordance with 22.4. strength…

22.4.3.1 …
WWW.CONCRETE.ORG/ACI318 32
Part 7: Strength & Serviceability

• 23: Strut-and-Tie Method

• 24: Serviceability

Δ ≤ l/360, 𝐼𝑒𝑓𝑓
WWW.CONCRETE.ORG/ACI318 33
Part 8: Reinforcement

• 25: Reinforcement Details

Lap ≥ 150 mm

WWW.CONCRETE.ORG/ACI318 34
Part 9: Construction

• 26: Construction Documents and Inspection

– 318 is written to the engineer, not the contractor.


– Construction requirements must be
communicated on the construction documents.
– All construction requirements are gathered
together in Chapter 26.
– Design information – job specific
– Compliance requirements – general quality
– Inspection requirements

WWW.CONCRETE.ORG/ACI318 35
Part 10: Evaluation

• 27: Strength Evaluation of Existing Structures

– Applies when strength is in doubt


– Well understood – analytical evaluation
– Not well understood – load test

WWW.CONCRETE.ORG/ACI318 36
Benefits of ACI 318 organization

• Organized from a designer’s perspective


• Easier to find specific requirements
• Intuitive location of information
• Clarified cross references
• Tables improve speed of understanding
• Consistent language in text
• Single idea for each requirement

WWW.CONCRETE.ORG/ACI318 37
1.4—Applicability

1.4.1 This Code shall apply to concrete


structures designed and constructed under the
requirements of the general building code.

1.4.3 Applicable provisions of this Code shall


be permitted to be used for structures not
governed by the general building code.

WWW.CONCRETE.ORG/ACI318 38
Concrete designs governed by other ACI codes

216 - Fire 307 - Chimneys 313 - Silos 332 – Residential

349 – Nuclear Facilities 350 – Environmental 359 – Nuclear Contain.

369 – Seismic Retrofit 376 – RLG Containment 437 – Strength Evaluation 562 - Repair

WWW.CONCRETE.ORG/ACI318 39
Design recommendations provided in guides

• Slabs-on-ground (ACI 360R)


• Blast-resistant structures (ACI 370R)
• Wire Wrapped Tanks (ACI 372R)

WWW.CONCRETE.ORG/ACI318 40
ACI 318-19
Changes to the Concrete
Design Standard

Existing Structures

WWW.CONCRETE.ORG/ACI318 41
1.4.2—Repair

1.4.2 Provisions of this Code shall be permitted


to be used for the assessment, repair, and
rehabilitation of existing structures.

R1.4.2 Specific provisions for assessment,


repair, and rehabilitation of existing concrete
structures are provided in ACI 562-19. Existing
structures in ACI 562 are defined as structures
that are complete and permitted for use.

WWW.CONCRETE.ORG/ACI318 42
Chapter 27 – Strength Evaluation of Existing
Structures
Applies when strength is in doubt
• Well understood – analytical evaluation
• Not well understood – load test
– Monotonic procedure, ACI 318
– Cyclic procedure, ACI 437.2

WWW.CONCRETE.ORG/ACI318 43
27.4.6.2—Total test load, Tt

Greatest of:
(a) Tt = 1.15D + 1.5L + 0.4(Lr or S or R)
→Tt = 1.0Dw + 1.1Ds + 1.6L + 0.5(Lr or S or R)
(b) Tt = 1.15D + 0.9L + 1.5(Lr or S or R)
→ Tt = 1.0Dw + 1.1Ds + 1.0L + 1.6(Lr or S or R)
(c) Tt = 1.3D
→Tt = 1.3(Dw + Ds)

WWW.CONCRETE.ORG/ACI318 44
ACI 318-19
Changes to the Concrete
Design Standard
High-Strength
Reinforcement

WWW.CONCRETE.ORG/ACI318 45
180 1200
A1035, Grade 100 (690)
160
1000

Stress, MPa
140
Stress, ksi

120 A706, Grade 100 (690) 800


100 A706, Grade 60 (420)
80 600
A615, Grade 40 (280)
60 400
40
200
20
0 0
0.00 0.05 0.10 0.15 0.20
Strain

WWW.CONCRETE.ORG/ACI318 48
Bar instability and low-cycle fatigue

Ghannoun, UT San Antonio

WWW.CONCRETE.ORG/ACI318 49
Ch. 20 –Seismic Requirements for A615 Gr. 420

• Section 20.2.2.5(b) permits ASTM A615


Grade 420 if:
– fy,actual ≤ fy + 125 MPa
– ft/fy ≥ 1.25
– Min. fracture elongation in 200 mm (10-14%)
– Minimum uniform elongation (6-9%)
• Section 20.2.2.5(b) provides the A706
elongation properties

WWW.CONCRETE.ORG/ACI318 50
Ch. 20 – Seismic Requirements for A615

• For seismic design ASTM A615 GR. 550 and


690 are not permitted

WWW.CONCRETE.ORG/ACI318 51
Table 20.2.2.4(a)

• Main changes
– Gr. 550
– Gr. 690
– Footnotes
– Clarifications

WWW.CONCRETE.ORG/ACI318 52
Ch. 20 – Steel Reinforcement Properties

WWW.CONCRETE.ORG/ACI318 53
Ch. 20 – Steel Reinforcement Properties

WWW.CONCRETE.ORG/ACI318 55
Ch. 20 – Steel Reinforcement Properties

WWW.CONCRETE.ORG/ACI318 56
High-strength reinforcement and design

• f for flexure and axial load


• Effective stiffness
• As,min
• Column axial strength
• Development length
• Many seismic detailing changes

WWW.CONCRETE.ORG/ACI318 57
Design limits
ACI 318M-14ACI 318-19

et ≥ 0.005
et ≥ (ety + 0.003)

WWW.CONCRETE.ORG/ACI318 58
Design limits
ACI 318-19

ACI 318-19 Provisions 7.3.3.1,


8.3.3.1, and 9.3.3.1 require
slabs and beams be tension
controlled

et ≥ (ety + 0.003)
fy
e ty =
Es
WWW.CONCRETE.ORG/ACI318 59
Design limits
ACI 318-14

WWW.CONCRETE.ORG/ACI318 60
Design limits
ACI 318-19

WWW.CONCRETE.ORG/ACI318 61
Design limits

fy
e ty =
Es

Reinforcement ratio, rtcl

f’c = 28 MPa f’c = 70 MPa


GR 420 et ≥ 0.0051 1.79% 3.42%
GR 550 et ≥ 0.00575 1.24% 2.37%
GR 690 et ≥ 0.0065 0.92% 1.75%

WWW.CONCRETE.ORG/ACI318 62
Design limits
GR 420 GR 690
As,tcl = 3866 mm2 As,tcl = 1987 mm2
Mn,tcl = 738 kNm Mn,tcl = 649 kNm

Reinforcement ratio, rtcl

Grade f’c = 28 MPa f’c = 70 MPa


400 x 600 mm beam 420 1.79% 3.42%
d = 540 mm 550 1.24% 2.37%
f’c = 28 MPa 690 0.92% 1.75%

WWW.CONCRETE.ORG/ACI318 63
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Cargas y Análisis

WWW.CONCRETE.ORG/ACI318 64
Capítulo 4: Requisitos para Sistemas Estructurales
Materiales
• Propósito Inspección
Cargas de
diseño
4.2
– La estructura como 4.13 4.3
un todo Resistencia Trayectoria
al fuego de cargas
– Mapa de ruta del 4.11 4.4
proceso de diseño
• Temario Integridad Análisis
estructural estructural
4.10 4.5
– Alcance
– 14 subsecciones Sostenibilidad Resistencia

4.9 4.6
Durabilidad Funcionamiento

4.8 4.7

WWW.CONCRETE.ORG/ACI318 65
4.2 Materiales
• Capítulo 19 - Concreto: requisitos de diseño y
funcionamiento
– fc’ (máximo y mínimo)
– Ec
– Modulo de ruptura fr
– Concreto liviano
– Categorías y Clases de exposición
– Propiedades de mortero de inyección
• Capítulo 20 – Propiedades del acero de refuerzo,
durabilidad y embebidos
– fy, Es
– Barras de refuerzo, aceros de preesfuerzo, barras con
cabeza, embebidos, …
– Durabilidad (recubrimiento de concreto, recubrimientos)

WWW.CONCRETE.ORG/ACI318 66
4.3 Cargas de diseño

• Cargas y combinaciones → Capítulo 5


– Cargas de diseño (muerta, viva, viento, sísmicas)
– Combinaciones de mayoración de carga
– Basadas en ASCE 7-10, “Minimum Design Loads
for Buildings and Other Structures”

WWW.CONCRETE.ORG/ACI318 67
4.4 Sistemas estructurales y trayectorias de
cargas
• Sistemas Losas de pisos Vigas y
estructurales y techos viguetas
Cap. 9
compuestos por Cap. 7 y 8

miembros y
conexiones
Muros
• Trayectorias de Columnas
Cap. 10 Cap. 11
cargas definidas
(gravedad y
lateral)
• Mapa de ruta de Diafragmas
Cap.12
Cimentaciones
Cap. 13
los capítulos de los
miembros
Conexiones
y anclaje

WWW.CONCRETE.ORG/ACI318 68
4.4 Sistemas estructurales y trayectoria de cargas

• Requisitos sísmicos
– Diseñador asigna la Categoría de Diseño Sísmico
• Categoría A (menor riesgo) a Categoria F (mayor
riesgo)
– Categoría A
• No hay requisitos especiales
• Diseño de acuerdo con los Capítulos 1-17, 19-26
• Pórticos resistentes a momento y muros Ordinarios
• Primordialmente comportamiento elástico

WWW.CONCRETE.ORG/ACI318 69
4.4 Sistemas estructurales y trayectoria de cargas

• Requisitos sísmicos
– Categorías B – F
• Requisitos → Capítulo 18
• Categoría B – pórticos y muros ordinarios
• Categoría C – Pórticos intermedios, muros ordinarios
• Categorías D, E, F – Pórticos y muros especiales
– Miembros que no son parte del sistema del
sistema de resistencia ante cargas laterales
• Requisitos de acuerdo con la Categoría de Diseño
Sísmico

WWW.CONCRETE.ORG/ACI318 70
Organización del capítulo 18

• La secciones de los pórticos resistentes a momento


ordinarios, intermedios y especiales son:
– 18.3 Pórticos ordinarios resistentes a momentos
– 18.4 Pórticos Intermedios resistentes a momentos
– 18.5 Muros estructurales intermedios prefabricados
– 18.6 Vigas de pórticos especiales a momentos
– 18.7 Columnas de pórticos especiales a momentos
– 18.8 Nudos de pórticos especiales a momentos
– 18.9 Pórticos especiales a momentos construidos con
concreto prefabricado
– 18.10 Muros de concreto especiales
– 18.11 Muros especiales construidos con concreto
prefabricado

WWW.CONCRETE.ORG/ACI318 71
4.4 Sistemas estructurales y trayectoria de cargas

• Diafragmas
– Fuerzas de transferencia
– Dar apoyo lateral

WWW.CONCRETE.ORG/ACI318 72
4.5 Análisis estructural

• Compatibilidad de deformaciones
• Equilibrio de fuerzas
• Métodos aceptables de análisis → Capítulo 6

4.6 Resistencia

• Resistencia de diseño = φSn


• φSn > U

WWW.CONCRETE.ORG/ACI318 73
4.7 Funcionamiento

• Está cubierto en los capítulos de miembros

4.8 Durabilidad
• La durabilidad del concreto depende de la
exposición
– Categoría de exposición → 19.3.1
– Requisitos para las mezclas →19.3.2
• Protección de la corrosión → 20.6

WWW.CONCRETE.ORG/ACI318 74
4.9 Sostenibilidad

• Se permite exceder los mínimos


• La resistencia, funcionamiento y
durabilidad tienen precedencia

4.10 Integridad estructural

• Mejora la redundancia y ductilidad


• Los requisitos se presentan en los capítulos
de los miembros

WWW.CONCRETE.ORG/ACI318 75
4.11 Resistencia al fuego

• Las dimensiones y recubrimiento de los


miembros deben cumplir los requisitos de
protección al fuego del reglamento
general de construcción
• Se dan guías adicionales en ACI 216.1

4.12 Tipos específicos de construcción

• Prefabricada, preesforzada, compuesta

WWW.CONCRETE.ORG/ACI318 76
4.13 Construcción e inspección

• Documentos de construcción → Capítulo


26
• Inspección
– Capítulo 26
– Reglamento general de construcción
4.14 Evaluación de la resistencia de
estructuras existentes
• Capítulo 27

WWW.CONCRETE.ORG/ACI318 77
Capítulo 5 - Cargas
• Cargas→ Reglamento general de
construcción
– Usualmente ASCE 7-10
– Si es considerablemente diferente de ASCE 7,
puede requerirse ajustar los requisitos de ACI 318
apropiadamente
• Viento
– Los factores basados en viento al nivel de
resistencia
– Multiplicar por 1.6 para viento al nivel de servicio

WWW.CONCRETE.ORG/ACI318 78
Capítulo 5 - Cargas
• Combinaciones
– Básicas → Tabla 5.3.1
– Excepciones y adiciones → Sección 5.3

WWW.CONCRETE.ORG/ACI318 79
Capítulo 5 – Cargas
• Categorías de diseño
sísmico (CDS)
– CDS → Reglamento
general de construcción
– Adoptado del ASCE 7-10
– Correlaciones Tabla
R5.2.2

WWW.CONCRETE.ORG/ACI318 80
Fuerzas de viento (R5.3.5)

• Comentario añadido
– ASCE 7-05
• Viento = viento para nivel de servicio
• Utilizar un factor de carga de 1.6

– ASCE 7-10 y ASCE 7-16


• Viento = viento para nivel de resistencia
• Utilice un factor de carga de 1.0

WWW.CONCRETE.ORG/ACI318 81
Capítulo 6 – Análisis estructural
• Suposiciones para definir el modelo
– Ancho del ala
– Momento de inercia
• Disposición de la carga viva
• Métodos de análisis permitidos
– Métodos simplificados
– Elástico de primer orden
– Elástico o inelástico de segundo orden
– Análisis utilizando elementos finitos

WWW.CONCRETE.ORG/ACI318 83
6.5 Método simplificado
• Vigas y losas en una dirección
– Mu → Tabla 6.5.2
– Vu → Tabla 6.5.4
– Restricciones
• Miembros prismático
• Cargas distribuidas
• L (viva) ≤ 3D (muerta)
• ≥ 2 vanos
• L1 < 1.2 L2
• No hay redistribución

WWW.CONCRETE.ORG/ACI318 84
6.6 Análisis de primer orden
• Cumple equilibrio para la estructura no
deformada
– Propiedades lineales de los materiales
– Solución lineal
– Superposición de cargas
– Efectos de esbeltez (si se requieren)
• Magnificador de momentos (aproximado)
– Cálculos manuales
– Momento de inercia efectivo
• Carga mayoradas → Tabla 6.6.3.1.1(a)
• Cargas de servicio → 1.4 x Tabla 6.6.3.1.1(a)

WWW.CONCRETE.ORG/ACI318 85
6.7 Análisis elástico de segundo orden
• Cumple equilibrio para la estructura
deformada
– Propiedades lineales de los materiales
– Solución no lineal
– No hay superposición de cargas
– Efectos de esbeltez
• No hay magnificación de momentos para el
desplazamiento relativo
• Se debe considerar la deflexión entre los extremos →
6.6.4.5
– Cálculos utilizando computador
– Momento de inercia efectivo
• Carga mayoradas → Tabla 6.6.3.1.1(a)
• Se permite utilizar I = 0.5 I g para todos los miembros o un
análisis mas detallado.

WWW.CONCRETE.ORG/ACI318 86
6.8 Análisis inelástico de segundo orden
• Consideraciones
– Materiales no lineales
– Se debe cumplir equilibrio en la configuración
deformada.
– No se permite redistribución de los momentos
calculados por medio de un análisis inelástico.

WWW.CONCRETE.ORG/ACI318 87
6.9 Aceptación de análisis utilizando
elementos finitos
• Método muy usado
• Apropiado para lo que se pretende
– Tipos de elementos
– Disposición y tamaño de la red
– Tipo de análisis (lineal, no lineal, dinámico)
– Resultados apropiados
• Dimensiones de los elementos dentro del
10% del tamaño final
• No se permite redistribución ni
superposición con análisis inelástico

WWW.CONCRETE.ORG/ACI318 88
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Losas en una dirección

WWW.CONCRETE.ORG/ACI318 105
Refuerzo para integridad estructural

Se han añadido requisitos sobre integridad


estructural
• Para mejorar la integridad estructural
– Para asegurar que la falla de una parte de una losa no
conduzca a un colapso desproporcionado
• Similar al de vigas
– Se hacen similares los requisitos de integridad
estructural de losas en una dirección construidas en
sitio con los requisitos de integridad estructural de vigas

WWW.CONCRETE.ORG/ACI318 106
Refuerzo de retracción y temperatura

7.6.4.1 → 24.4 Refuerzo de retracción y temperatura

24.4.3.2 : La cuantía refuerzo corrugado de retracción y


temperatura calculada con respecto al área bruta de
concreto
• 318S-14: según la tabla 24.4.3.2

• 318-19: Cuantía ≥ 0.0018


WWW.CONCRETE.ORG/ACI318 110
Refuerzo mínimo a flexión en losas no
preesforzados — en una dirección
7.6.1.1:
• 318-14: As,min según la tabla 7.6.1.1

• 318-19: As,min = 0.0018Ag

WWW.CONCRETE.ORG/ACI318 111
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Losas en dos direcciones

WWW.CONCRETE.ORG/ACI318 112
Método de diseño directo y Método del
pórtico equivalente
– Ha sido removido: El método de diseño directo (8.10)
y el método del pórtico equivalente (8.11)

– Requisitos en 318-14

– 8.2.1… Se permite el método de diseño directo o el


método del pórtico equivalente.

– 6.2.4.1 Se permitirá que las losas en dos direcciones


sean analizadas en busca de cargas de gravedad
de acuerdo con (a) o (b):
(a) Método de diseño directo para losas no preesforzadas
(b) Método del pórtico equivalente para losas no
preesforzadas y preesforzadas

WWW.CONCRETE.ORG/ACI318 113
Cabezas de cortante

• Requisitos para
cabezas de cortante
en 318-14 han sido
removidos
– 8.4.4.1.3 Las losas
reforzadas con cabezas
de cortante se deben
evaluar para cortante
en dos direcciones en
las secciones críticas de
acuerdo con 22.6.9.8.

WWW.CONCRETE.ORG/ACI318 114
Abertura en sistemas de losa sin vigas
ACI 318-14: 8.5.4.2(d)
• dentro de las franjas de columna o
a una distancia menor a 10h de
una carga concentrada o zona de
reacción, deben cumplir con
– 22.6.4.3 para losas sin cabeza de
cortante
– o 22.6.9.9 para losas con cabeza de
cortante

• 22.6.4.3: Perímetro reducido de la


sección crítica (bo)
– Fig. R22.6.4.3
Fig. R22.6.4.3—Efecto de aberturas en la
losa y extremos libres (las líneas
• 22.6.9.9: La reducción a bo es ½ de discontinuas muestran el perímetro
la dada en 22.6.4.3
efectivo)
Nota: Las aberturas mostradas están
localizadas dentro de 10h de la periferia
de la columna
WWW.CONCRETE.ORG/ACI318 115
Abertura en sistemas de losa
sin vigas
ACI 318-19: 8.5.4.2(d)
• A una distancia menor a
4h de la periferia de una
columna, de una carga
concentrada o zona de
reacción se debe
cumplir con 22.6.4.3

• 22.6.4.3: Perímetro Fig. R22.6.4.3—Efecto de aberturas en la


reducido de la sección losa y bordes libres (las líneas discontinuas
crítica (bo) muestran el perímetro efectivo)

– Fig. R22.6.4.3

WWW.CONCRETE.ORG/ACI318 116
Refuerzo mínimo a flexión en losas no
preesforzadas — Dos direcciones
8.6.1.1
• 318-14: As,min según la Tabla 8.6.1.1.

• 318-19: As,min de 0.0018Ag, o como se define en


8.6.1.2 (discutido bajo cortante en dos direcciones)

WWW.CONCRETE.ORG/ACI318 117
Extensiones de refuerzo para losas sin vigas

ACI 318-14: 8.7.4.1.3 —


Barras superiores de franja
de columna
• Extienda al menos 0.3ℓn
• Puede no ser suficiente
para losas gruesas
– puede no interceptar fisuras
críticas de cortante por
punzonamiento
– Reduce la resistencia a
cortante por
punzonamiento Fisuras de cortante por
punzonamiento en losas con
extensiones de refuerzo

WWW.CONCRETE.ORG/ACI318 118
Falla de cortante por punzonamiento —
Losa de podio Acero superior (34 barras No. 9)
50% to 0.2L (2400 mm)

50% to 0.2L (1600 mm)


35 mm

600 mm
Columna 300x1100
(no se muestra el refuerzo para mayor claridad)

• La fisura de la falla no interceptó el refuerzo superior.

WWW.CONCRETE.ORG/ACI318 119
Extensiones de refuerzo para losas en dos
direcciones sin vigas
ACI 318-19: 8.7.4.1.3 d
— Barras superiores
de franja de columna
• Extienda al menos
0.3ℓn pero, no d
menos de 5d

Fig. R8.7.4.1.3 — Fisuras de cortante por


punzonamiento en losas normales y gruesas

WWW.CONCRETE.ORG/ACI318 120
Extensiones de refuerzo para losas en dos
direcciones sin vigas

WWW.CONCRETE.ORG/ACI318 121
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Postensado

WWW.CONCRETE.ORG/ACI318 122
Losas residenciales P-T (1.4.6)

• Confusión en el pasado sobre el diseño de


cimientos de losas P-T en suelos expansivos
– La intención era para uso residencial, pero no se
menciona en los requisitos de diseño residencial.
• El comentario aclara el uso del PTI DC10.5-12
para losas residenciales P-T y cimientos en
suelos expansivos

WWW.CONCRETE.ORG/ACI318 123
Losas residenciales P-T (1.4.6)

• Se coordina con los requisitos del IBC 2015


• Añade referencia a ACI 360 si no está en
suelo expansivo

WWW.CONCRETE.ORG/ACI318 124
Máx. Espaciamiento del refuerzo corrugado
(7.7.2.3)

• Clase C (fisuradas) y T (de transición) losas


en una dirección con tendones no
adheridos dependen del refuerzo adherido
para el control de fisuras
• Anteriormente no había límites de
espaciamiento del refuerzo corrugado para
losas preesforzadas Clase C y T
• Se incluyen comentarios de la industria

WWW.CONCRETE.ORG/ACI318 125
Max. Espaciamiento del refuerzo corrugado
(7.7.2.3)

• El nuevo límite es s ≤ 3h y 450 mm


• Igual que las losas no preesforzadas

P-T no adherido Refuerzo


corrugado

s ≤ 3h y 450 mm
Sección de la losa
WWW.CONCRETE.ORG/ACI318 126
Refuerzo de la zona de anclaje P-T (25.9.4.4.6)

• Referido de los capítulos de losa y viga


• Aplicable para grupos de 6 o más anclajes en losas
gruesas
• La zona de anclaje requiere barras de respaldo para
apoyo y horquillas para el estallido del concreto
• Las horquillas deben estar ancladas en las esquinas

Horquillas

Barras de respaldo
Barras de anclaje
WWW.CONCRETE.ORG/ACI318 127
WWW.CONCRETE.ORG/ACI318 128
Refuerzo de la zona de anclaje P-T
(25.9.4.4.6)
• Losas delgadas ≤ 200 mm → Las barras de
anclaje sirven como barras de respaldo

• Losas gruesas > 200 mm → Tanto barras de


respaldo como barras de anclaje son
requeridas
Horquillas

Barras de respaldo Barras de anclaje


WWW.CONCRETE.ORG/ACI318 129
WWW.CONCRETE.ORG/ACI318 130
WWW.CONCRETE.ORG/ACI318 131
WWW.CONCRETE.ORG/ACI318 132
Diseño del encofrado para P-T (26.11.1.2 (5) y
(6))

• Los miembros pueden moverse cuando el


torón P-T es tensionado
• El movimiento puede redistribuir las cargas
• Requisito adicional para permitir el
movimiento durante la tracción
• Requisito adicional para considerar la
redistribución de las cargas sobre el
encofrado debido a la tracción del refuerzo
preesforzado

WWW.CONCRETE.ORG/ACI318 133
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Prefabricado/Preesforzado

WWW.CONCRETE.ORG/ACI318 134
Concreto prefabricado / Concreto preesforzado

• Confinamiento para las


partes superiores de
columnas/pedestales
• Fuerzas de conexión
• Requisito para incluirlos
en los documentos de
construcción
• f en los extremos de
los miembros
prefabricados

WWW.CONCRETE.ORG/ACI318 135
Confinamiento

• 10.7.6.1.5: confinamiento es requerido en la


parte superior de las columnas/pedestales
• Ayuda en la transferencia de carga
• No es un requisito nuevo Pernos de
anclaje

125 mm

Dos N°. 13 o
Tres barras N°. 10

WWW.CONCRETE.ORG/ACI318 136
Confinamiento

• 10.7.6.1.6: extiende el requisito de


confinamiento a las columnas y pedestales
prefabricados
Futuro miembro
prefabricado
125 mm
Acoples mecánicos

Dos N° 13 o
Tres barras N° 10
WWW.CONCRETE.ORG/ACI318 137
Cambios volumétricos en conexiones
prefabricadas

• Cambios volumétricos
– Asentamiento por flujo plástico
– Retracción
– Temperatura
• Puede inducir reacciones de conexión si se
restringe

WWW.CONCRETE.ORG/ACI318 138
Cambio de volumen en conexiones
prefabricadas

• Magnitud de la carga?
• ¿Factor de la carga?
• Orientación pasada
para cartelas y
ménsulas
– Use Nuc ≥ 0.2Vu como
fuerza de retención
– Utilizar un factor de carga
de 1.6
• El enfoque a menudo
consistía en diseñar
alrededor de fuerzas
WWW.CONCRETE.ORG/ACI318 139
Cambio de volumen y conexiones
318-19 cambios (16.2.2.3)
• Nuc = fuerza de contención
mayorada, deberá ser (a) o (b)
– (a) fuerza de retención x factor LL
(sin almohadilla de apoyo)
– (b) 1.6 x 0.2 (carga vertical sostenida
no mayorada) para conexiones en
almohadillas de apoyo
• Nuc,max ≤ capacidad de
conexión x factor LL
• Nuc,max ≤ 1.6 x μ x (carga vertical
sostenida no mayorada) si se
conoce μ, (Véase 16.2.2.4)
WWW.CONCRETE.ORG/ACI318 140
Cartelas y ménsulas
• 26.6.4.1(a) Detalles para la soldadura de las barras
de anclaje en la cara frontal de las cartelas o
ménsulas diseñados por el profesional facultado
para diseñar de acuerdo con 16.5.6.3(a).

Fig. R16.5.6.3b Fig. R16.5.1b


WWW.CONCRETE.ORG/ACI318 141
Factor de reducción de resistencia
Cercano al final del
miembro prefabricado
• Interpolación lineal
de f
• f p depende del
estado de esfuerzo

WWW.CONCRETE.ORG/ACI318 142
Factor de reducción de resistencia

Cercano al final
del miembro
prefabricado
• Similar para
torones
despegados

WWW.CONCRETE.ORG/ACI318 143
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Secciones circulares

WWW.CONCRETE.ORG/ACI318 144
Definiciones de variables (22.5)

• 22.5 Resistencia a cortante en una dirección


– Interpretación para secciones circulares huecas

d?
abertura

ρw ?
bw ?

WWW.CONCRETE.ORG/ACI318 145
Definiciones de variables (22.5)
• 22.5.2.2 — cálculo de Vc y Vs
– d = 0.8 x diámetro
– bw = diámetro (círculos sólidos)
– bw = 2 x espesor del muro (círculos huecos)
t

d = 0.8D
abertura

ρw = As/bwd
bw = D bw = 2t
WWW.CONCRETE.ORG/ACI318 146
Definiciones de variables (22.5)

• ¿Qué hay de As?

(2/3)D

As

WWW.CONCRETE.ORG/ACI318 147
Torsión para secciones circulares (R22.7.6.1.1)
• ¿Se aplican las ecuaciones de torsión de ACI
318 a las secciones transversales circulares?
• Las ecuaciones del reglamento se basan en la
teoría del tubo delgado
• Ejemplos añadidos a la figura

WWW.CONCRETE.ORG/ACI318 148
Juntas de Columna
Circular
• Basado en una columna
cuadrada equivalente
– Aj para la resistencia a h = 0.89D
cortante de la junta (15.4.2)
– Anchura de las vigas
transversales necesaria para
que el nudo se considere
confinado (15.2.8)
– Ancho de columna ≥ 20 db
para pórticos especiales
resistentes a momentos
(18.8.2.3)

WWW.CONCRETE.ORG/ACI318 149
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Muros

WWW.CONCRETE.ORG/ACI318 150
Alcance de los muros

• Cambio de alcance
11.1.4- El diseño de los muros de contención en
voladizo debe estar de acuerdo con el Capítulo 13
(Cimentaciones)

WWW.CONCRETE.ORG/ACI318 151
Alcance de los muros

• Alcance adicional
11.1.6- Muros CES con encofrados aislantes serán
permitidos a usarse en edificios de uno o dos pisos de
acuerdo a este reglamento
• Diseño de acuerdo al Capítulo 11
• Orientación — ACI 560R y PCA 100-2017
• Problemas de construcción únicos

Foto: cortesía de Larry Novak


WWW.CONCRETE.ORG/ACI318 152
11.7.2.3 Colocación de las barras

• Si el espesor del muro h > 250 mm


• Dos capas de barras cerca de cada cara
• Excepción, muros de sótano de un solo piso

• 318S-14
• ½ a 2/3 del refuerzo es colocado cerca de
la cara exterior
• El resto del refuerzo es colocado cerca de
la cara interior

• Confusión entre el exterior y el interior


– Localización en la cara vs. el muro
• ½ a 2/3 era arbitrario

WWW.CONCRETE.ORG/ACI318 153
14.6 Concreto simple
En ventanas, aberturas de puertas, y en
aberturas de tamaño similar
• Por lo menos dos barras n.º 16 (similares a
muros 11.7.5.1)
• Extienda 600 mm más allá o hasta
desarrollar fy

2 — barras
n.º 16

≥ 600 mm

WWW.CONCRETE.ORG/ACI318 154
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Cimentaciones

WWW.CONCRETE.ORG/ACI318 155
Cap. 13 — Cimentaciones — cambios
significativos
• Requisitos de diseño añadidos
– Muros de contención en voladizo

– Diseño de cimentaciones profundas

• Otros
– Resistencias mínimas del concreto para
cimentaciones superficiales y profundas

– Recubrimiento

WWW.CONCRETE.ORG/ACI318 156
Cimentaciones y 318
• ACI 318-71 (ACI 318S-05)
a ACI 318S-08 (Capítulo
15)
• Zapatas superficiales,
cabezales de pilotes

• ACI 318S-14 (Capítulo 13)


• Zapatas superficiales,
cabezales de pilotes

WWW.CONCRETE.ORG/ACI318 157
Cimentaciones y 318
• ACI 318-71 (ACI 318S-05) a
ACI 318S-08 (Capítulo 15)
• Zapatas superficiales,
cabezales de pilotes

• ACI 318S-14 (Capítulo 13)


• Zapatas superficiales,
cabezales de pilotes

• ACI 318-19 (Capítulo 13)


• Zapatas superficiales,
cabezales de pilotes,
cimentaciones profundas y
muros de contención en
voladizo

WWW.CONCRETE.ORG/ACI318 158
Muros de contención en voladizo
Es una
losa
Es un
(2019)
muro
(2014)

WWW.CONCRETE.ORG/ACI318 159
13.3.6.1 — El alma de un muro en voladizo
• Debe diseñarse como una losa
de una dirección (Cap. 7)

WWW.CONCRETE.ORG/ACI318 160
13.3.6.2 — El alma de un muro en voladizo con
contrafuerte
• Debe diseñarse como una losa en dos direcciones (Cap. 8)

WWW.CONCRETE.ORG/ACI318 161
Espaciamiento máximo entre barras en el
alma del muro
Muro Losa
Diseño
Diseño como
Refuerzo Espaciamiento Espaciamiento
como losa de
del alma del máximo entre máximo entre
muro una
muro barras (2014) barras (2019)
(2014) dirección
Barras
(2019) longitudinales
El menor de:
Longit.
s Barras
(Muro) o 3h, o 7.7.2.2 transversales
11.7.2.1
Flexión 450 mm (24.3)
(Losa)

Transv.
3h, o 5h, o
(Pared) o S 11.7.3.1 7.7.6.2.1
450 mm 450 mm
& T (Losa)
WWW.CONCRETE.ORG/ACI318 162
Refuerzo mínimo en el alma del muro
ACI 318S-14 ACI 318-19
Diseño
Diseño como Refuerzo mínimo como
Refuerzo mínimo, ρ
muro As,min losa en una
dirección
≤ n.º 16
ρℓ = 0.0012 As,min = 0.0018 Ag
11.6.1 7.6.1.1
> n.º 16
ρℓ = 0.0015

≤ n.º 16
ρt = 0.0020 AS+T = 0.0018 Ag 7.6.4.1
11.6.2
> n.º 16 (24.4)
ρt = 0.0025

WWW.CONCRETE.ORG/ACI318 163
1.4.7 —Cambios en el alcance — cimentaciones
profundas
• Alcance: Este reglamento no gobierna el diseño e
instalación de porciones de pilotes de concreto, pilas
excavadas y cajones de cimentación enterrados en
el suelo, excepto como se estipula en (a) a (c)
• (a) Para porciones en el aire o en el agua, o en el suelo
incapaces de dar soporte lateral adecuado para evitar el
pandeo a lo largo de toda su longitud

• (b) Para pilotes de concreto prefabricado que soporten


estructuras asignadas a las CDS A y B

• (c) Para elementos profundos de cimentación que soporten


estructuras asignadas a las CDS C, D, E y F (el CDS C se
añade al alcance)

WWW.CONCRETE.ORG/ACI318 164
Cimentaciones profundas (13.4)

• 13.4.1 Generalidades
• 13.4.2 Resistencia axial permisible
• 13.4.3 Diseño por resistencia
• 13.4.4 Cimentaciones profundas construidas en sitio
• 13.4.5 Pilotes de concreto prefabricado
• 13.4.6 Cabezales de pilotes

WWW.CONCRETE.ORG/ACI318 165
Cimentaciones profundas — combine IBC &
ASCE 7
• ACI 318 – 19 –
CIB
– IBC 2015 combinado, ASCE 7-10 ASCE 7
2015

y ACI 318S-14 con respecto al ACI


318S-14
diseño de cimentaciones
profundas para estructuras
ACI 318 - 19
resistentes a sismos (CDS C, D, E
Capacidades axiales
permisibles de
y F) resistencia/esfuerzo

WWW.CONCRETE.ORG/ACI318 166
Pre- ACI 318-19 — diseño de cimentaciones
profundas
• ACI 543 — Pilotes (diam. < 750
mm)
• ACI 336.3 — Diseño de pilares
excavados (diam. ≥ 750 mm)
No son documentos en
lenguaje de reglamento
También se utilizan los requisitos
de zapatas profundas de:
IBC y ASCE/SEI 7

WWW.CONCRETE.ORG/ACI318 167
• Diseño de la resistencia axial de
los miembros de acuerdo con
dos métodos:
– Diseño de resistencia axial permisible
(13.4.2)
– Diseño por resistencia (13.4.3)

Fotos cortesía de Larry Novak


WWW.CONCRETE.ORG/ACI318 168
Método de resistencia axial permisible (13.4.2)
13.4.2.1 El diseño de un miembro de cimentación profunda
debe ser permitido utilizando combinaciones de carga
para el diseño por esfuerzos permisibles en ASCE/SEI 7,
Sección 2.4, y la resistencia permisible especificada en la
Tabla 13.4.2.1 si (a) y (b) se cumplen
(a)La cimentación profunda es apoyada lateralmente en
toda su altura
(b)Fuerzas aplicadas que causan momentos de flexión
inferiores al momento debido a una excentricidad
accidental del 5 por ciento del diámetro o ancho del
pilote.

WWW.CONCRETE.ORG/ACI318 169
13.4.2 diseño de cimentación profunda

WWW.CONCRETE.ORG/ACI318 170
Confinamiento de la camisa metálica (13.4.2.3):
Diámetro ≤ 400 mm
• no es usada para resistir cargas
axiales
• punta sellada hincada con mandril
• sin costura o soldada sin costura

Propiedades físicas Camisa


metálica
• grosor de la camisa ≥ calibre 14
(1.7 mm)
• fy ≥ 210 MPa (2100 kg/cm2)
• fy ≥ 6 f’c , y
• diámetro nominal ≤ 400 mm Punta
sellada

WWW.CONCRETE.ORG/ACI318 171
Cimentaciones profundas — diseño por
resistencia (13.4.3)
Pu
• El método puede ser utilizado en Mu ≥ 0
cualquier momento
• Se debe utilizar el método cuando el
pilote no cumple los criterios para el
diseño de la resistencia axial permisible
– El suelo no proporciona apoyo lateral
– El momento no es insignificante

• Utilice la Sección 10.5 (columnas)


– 𝝓 Pn ≥ P u
– 𝝓 Mn ≥ Mu
– Pn y Mn combinados calculados en un 22.4

WWW.CONCRETE.ORG/ACI318 172
Diseño por resistencia (13.4.3) — fuerza axial, sin
momento
Resistencia nominal a la compresión axial; Pn Pu Mu= 0
𝝓 Pn,máx. ≥ Pu
Resistencia axial máxima
— Para miembros de cimentaciones
profundas con estribos que cumplen con
el Capítulo 13 (nuevo en la Tabla 22.4.2.1)
Pn,max. = 0.80 Po

Dónde:
Po = fuerza axial nominal con
excentricidad cero
Po = 0.85f’c(Ag – Ast) + fyAst

WWW.CONCRETE.ORG/ACI318 173
Diseño por resistencia (13.4.3) — fuerza axial, sin
momento
• Factor de reducción — Tabla 13.4.3.2 Pu Mu= 0

0.55 a
0.70

WWW.CONCRETE.ORG/ACI318 174
Cimentaciones profundas

13.4.4.1 Cimentaciones
profundas CES que estén
sometidas a (a) Confinado para
levantamiento o (b) Mu > ductilidad

0.4Mcr deben reforzarse, a


menos que estén
circundadas por una tubería Reforzado para la

o tubo de acero
flexión

Reforzado para la
tracción

Sin refuerzo

WWW.CONCRETE.ORG/ACI318 175
Tabla 19.2.1.1 — Limites para f'c

WWW.CONCRETE.ORG/ACI318 176
Recubrimiento de concreto — cimentaciones
profundas Tubo de
acero
Tabla 20.5.1.3.4

75 mm 40 mm

Construido en sitio Construido en sitio


contra el suelo rodeado por un tubo de
acero, una camisa
permanente o en perfil
de roca estable
WWW.CONCRETE.ORG/ACI318 177
Recubrimiento de concreto — cimentaciones
profundas
Tabla 20.5.1.3.4

Prefabricado no preesforzado prefabricado no preesforzado


de 40mm y prefabricados de 65 mm prefabricado
preesforzados preesforzado de 50 mm

En contacto con el suelo Expuesto al agua de mar


WWW.CONCRETE.ORG/ACI318 178
ACI 318-19
Changes to the Concrete
Design Standard
Anchorage to
Concrete

WWW.CONCRETE.ORG/ACI318 179
Chapter 17 – Anchoring to Concrete

• Reorganized
• New content/design
information
– Screw anchors
– Caution about using
reinforcement for
anchorage
– Shear lugs

WWW.CONCRETE.ORG/ACI318 180
Sections

• 17.1 Scope • 17.9 Edge distances,


• 17.2 General spacings, and
• 17.3 Design limits thicknesses to
preclude splitting
• 17.4 Required strength failure
• 17.5 Design strength • 17.10 Earthquake-
• 17.6 Tensile strength resistant design
• 17.7 Shear strength requirements
• 17.8 Tension and • 17.11 Attachments
shear interaction with shear lugs

WWW.CONCRETE.ORG/ACI318 181
Ch. 17 – Anchoring to Concrete

Scope
• Headed studs and
headed bolts
• Hooked bolts
• Post-installed
undercut anchors
• Post-installed
expansion anchors
• Post-installed
adhesive anchors
WWW.CONCRETE.ORG/ACI318 182
Screw Anchors (17.3.4)

• For screw anchors satisfying:


– hef ≥ 40 mm and
– 5da ≤ hef ≤ 10da
• Manufacturer provides hef, Aef, hhole hef
and pullout strength hnom

• Concrete breakout evaluated


similar to other anchors da

– 17.6.2 in tension
– 17.7.2 in shear

WWW.CONCRETE.ORG/ACI318 184
Minimum Spacing (17.9.2a)

• Screw anchor spacing limited per Table


17.9.2a Greatest of:
(a) Cover
Spacing > 0.6hef (b) 2 x max. agg.
and 6da (c) 6da or per
ACI 355.2

WWW.CONCRETE.ORG/ACI318 185
17.1.6 – Reinforcement used as anchorage

Consider an anchorage plate with many bars


anchored in concrete.
Is it sufficient to only provide ℓd for the bars?

ℓd

anchorage
plate
photo compliments of P. Carrato
WWW.CONCRETE.ORG/ACI318 186
17.1.6 – Reinforcement used as anchorage

• Check development
length per chapter 25,
and
• Check breakout
strength per chapter 17.
– Straight bars behave like
adhesive anchors
– Hooked and headed bars
behave like headed
anchors
– Anchor reinforcement
may be an alternative

WWW.CONCRETE.ORG/ACI318 187
Shear Lugs (17.11.1)

Shear lugs are


fabricated from:
• Rectangular plates
or
• Steel shapes
composed of plate-
like elements,
welded to an
attachment base
plate

WWW.CONCRETE.ORG/ACI318 189
Shear Lug Detailing (17.11.1.2)

• Steel plate to have 25 mm dia. (min.) hole


• Single plate – one on each side
• Cross / cruciform plate - one each quadrant
• More vent holes are not detrimental

WWW.CONCRETE.ORG/ACI318 190
Stiffeners

• 17.11.2.3 - If used, the length of shear lug


stiffeners in the direction of the shear load
shall not be less than 0.5hsl

T/Conc

Stiffener hsl
0.5hsl

Shear lug

WWW.CONCRETE.ORG/ACI318 191
Shear Lugs (17.11.1)

• Minimum four
anchors
• Anchors:
– If not welded, then
design assuming no
anchor shear.
– If welded, then
design anchors to
resist portion of shear
(in combination with
other actions)

WWW.CONCRETE.ORG/ACI318 192
Shear Lug Detailing (17.11.1.1.8)

• Anchors in tension, satisfy both (a) and (b):


(a) hef/hsl ≥ 2.5
(b) hef/csl ≥ 2.5

WWW.CONCRETE.ORG/ACI318 193
Shear Lug Overturning (17.11.1.1.9)

hsl

hef

tsl

Csl

WWW.CONCRETE.ORG/ACI318 194
Bearing (17.11.2)

• f Vbrg,sl ≥ Vu

• Where f = 0.65

Source: Peter Carrato

WWW.CONCRETE.ORG/ACI318 195
Bearing Strength
Vbrg ,sl = 1.7 f Aef ,sl  brg ,sl
c
'

Direction of
shear load

Direction of
shear load

WWW.CONCRETE.ORG/ACI318 198
17.11.2.2 – Bearing factor

Tension load
V = 1.7 f A
brg , sl c
'
ef , sl 
brg , sl

• Ψbrg,sl = 1 + Pu/(nNsa) ≤ 1.0


• Pu – negative for tension
• n – number of anchors in tension
• Nsa – Nominal tension strength of a single anchor

No applied axial load: Ψbrg,st = 1

Compression load: Ψbrg,sl = 1 + 4Pu/(Abpfc’) ≤ 2.0


• Pu – positive for compression
WWW.CONCRETE.ORG/ACI318 199
17.11.2.4 – Bearing for Multiple Shear Lugs

• If τ ≤ 0.2 f’c, use bearing from


both lugs

τ = Vu/(A1 + A2)
A2
A1

WWW.CONCRETE.ORG/ACI318 200
17.11.3 – Concrete breakout strength of
shear lugs

• Nominal concrete breakout strength of a


shear lug
– Use Anchor provisions of 17.7.2
AVc
Vcb ,sl =  ed ,V  c ,V  h,V Vb
AVco

• Where:

WWW.CONCRETE.ORG/ACI318 201
17.11.3.4 – Breakout for Multiple Shear Lugs

• Determine for each potential breakout


surface
• Commentary directs to Fig. R17.7.2.1b

WWW.CONCRETE.ORG/ACI318 202
Shear Lug Example

• Reinforced Concrete Design Manual


• Anchorage example 20 75 mm
Non-shrink
• See handout grout

(2) #13 diamond ties in top 125 mm


DV = 265 kN
LV = 335 kN 200 mm
WV = ±755 kN
DH = ± 36 kN

800 mm
LH = ± 40 kN
WH = ±53 kN

200 mm
Pedestal
800 mm
f’c = 31 MPa

WWW.CONCRETE.ORG/ACI318 203
Shear Lug Example
• Can we replace upper ties with shear lug?
– Remove shear from anchor rod design
– May reduce bolt size/length 400
110
– Simplify design
50 typ.
40 mmx 535 mmx 535 mm
steel plate No. 13

W360 (8) ties ties


No. 25
200 400 800

75 300
75

660 mm 800

WWW.CONCRETE.ORG/ACI318 204
Size Shear Lug

• Size shear lug so entire lug is effective


– tsl = 40 mm
– Width = 40 mm+ 4(40 mm)
V
= 200 mm
– Depth = 75 mm + 75 mm T/Conc
= 150 mm 75 mm
– Stiffeners at least 0.5 hsl or 40 mm wide 40 mm

WWW.CONCRETE.ORG/ACI318 205
Shear Lug Example

• Check anchor rod depth (only required if


attachment has tension)
– hef/hsl ≥ 2.5 → hef = 2.5 (75 mm) = 190 mm
– hef/csl ≥ 2.5 → hef = 2.5 (200 mm) = 500 mm (controls)

– Increase rod embedment


from 450 mm to 500 mm hsl = 75
hef
csl = 200

400

WWW.CONCRETE.ORG/ACI318 206
Strength Checks

• Vua,g ≤ f Vbrg,sl (bearing)


≤ f Vcb,sl (concrete breakout)
• f = 0.65
40 mm x 535 mm x 535 mm
steel plate

W360

75
75

660 mm

WWW.CONCRETE.ORG/ACI318 207
Bearing Strength Check
V
• Vua,g ≤ f Vbrg,sl (bearing)
– Vua,g = 133 kN 1.7 f’c
– Vbrg,sl = 1.7 f’c Aef,sl Ψbrg,sl
• For tension on attachment, bearing is reduced
– Pu = -516 kN (Max. vertical tension from, 1.2D ± 1.0W)
– Ψbrg,sl = 1+Pu/(nNsa)
– = 1+(-516 kN)/(4 rods(323 kN/rod))= 0.601
– Vbrg,sl = 1.7 (31 MPa)(200 mm)(75 mm)(0.601) = 475 kN

• f Vbrg,sl = 0.65 (475 kN) = 309 kN > 133 kN OK


WWW.CONCRETE.ORG/ACI318 208
Concrete Breakout Strength Check

• Vua,g ≤ f Vcb,sl (concrete breakout)


• Vcb,sl = (AVc/AVc0) Ψed,V Ψc,V Ψh,V Vb
– AVc = [75 + 1.5 (800 -75)/2](800)-(75)(200)
= 501,000 mm2 = 5,010 cm2

V ca1 = 380 mm

75 mm

572 mm

800 mm 800 mm

WWW.CONCRETE.ORG/ACI318 209
Concrete Breakout Strength Check

• Vcb,sl = (AVc/AVc0) Ψed,V Ψc,V Ψh,V Vb


– AVc0 = 4.5 ca12 = 4.5(380 mm)2 =649,800 mm2
= 6,498 cm2

AVco
ca1 = 380 mm
1.5 ca1

1.5 ca1

800 mm

WWW.CONCRETE.ORG/ACI318 210
Concrete Breakout Strength Check

• Vcb,sl = (AVc/AVc0) Ψed,V Ψc,V Ψh,V Vb


– Ψed,V = edge effect modification factor
= 0.7 + 0.3ca2/(1.5ca1)
= 0.7+0.3(300)/(1.5(380))=0.86

ca1 = 380 mm

ca2 = 300 mm

800 mm

WWW.CONCRETE.ORG/ACI318 211
Concrete Breakout Strength Check

• Vcb,sl = (AVc/AVc0) Ψed,V Ψc,V Ψh,V Vb


– Ψc,V = concrete cracking modification factor
– Assume cracking and No. 4 ties between lug and
edge (see Table 17.7.2.5.1)
– Ψc,V = 1.2

– Ψh,V = member thickness modification factor


=1.0 (depth > 1.5 ca1)

– Vb = 3.7λaf’c(ca1)1.5
= 3.7(1)(31 MPa)(380 mm)1.5 = 153 kN
WWW.CONCRETE.ORG/ACI318 212
Concrete Breakout Strength Check

• Vcb,sl = (AVc/AVc0) Ψed,V Ψc,V Ψh,V Vb


= (5,010 cm2/6,498 cm2)(0.86)(1.2)(1.0)(153 kN)
= 122 kN

• f Vcb,sl = 0.65 (122 kN)


= 79 kN < 133 kN No Good

WWW.CONCRETE.ORG/ACI318 213
ACI 318-19
Changes to the Concrete
Design Standard
Seismic Design
Philosophy

WWW.CONCRETE.ORG/ACI318 216
Seismic

• Both concrete and


reinforcement are
permitted to
respond in the
inelastic range
• This is consistent
with the strength
design approach
adopted throughout
the Code

WWW.CONCRETE.ORG/ACI318 217
Seismic – Ω, Cd, and R Factors (ASCE 7)
Lateral
seismic
force, V E
𝑉𝑒

Idealized elastic
response of
structure
𝑉𝑒 Fully yielded strength (b) Sequence of plastic hinge
× Ω𝑜
𝑅Τ𝐼𝑒 formation (Degenkolb)
Successive yield
Member hinges
𝑉𝑒 overstrength
of first hinge Design force level

𝑅Τ𝐼𝑒
Δ Cd Δ Lateral drift, D

(a) Relation between base-shear


and roof drift (ASCE 7)

WWW.CONCRETE.ORG/ACI318 218
Seismic – Parameters
Parameter in ASCE 7-16 Example
Table 12.2-1
Special reinforced
Seismic Force Resisting
concrete shear walls
System
(building frame system)
ASCE 7 Section Where
ASCE 7 Section 14.2
Detailing Requirements Are
“Concrete”
Specified
Response Modification
6
Coefficient, R
Overstrength Factor, Ω0 2.5
Deflection Amplification
5
Factor, Cd
SDC B No limit
Structural System SDC C No limit
Limitations, Including SDC D 160 ft
Structural Height Limits SDC E 160 ft
SDC F 100 ft

WWW.CONCRETE.ORG/ACI318 220
2
Seismic
• Controlled inelastic action is permitted at pre-
determined locations, called plastic hinges
• Typical plastic hinge locations are at the ends
of beams in moment frames, and at the bases
of shear walls

WWW.CONCRETE.ORG/ACI318 221
Seismic
• Prescriptive rules for
detailing of
reinforcement are
enforced, creating
robust plastic hinges
• Plastic hinging
reduces the stiffness
of the structure,
which lengthens the
period; and plastic
hinges dissipate
earthquake energy

WWW.CONCRETE.ORG/ACI318 222
ACI 318-19
Changes to the Concrete
Design Standard
Intermediate and
Special Moment
Frames

WWW.CONCRETE.ORG/ACI318 223
18.6.3.1 and 18.8.2.3—Special moment frame
beams (and joints)

• Longitudinal Reinforcement
hc/20 (Gr 420)
@ interior joints, 𝑑𝑏 ≤
hc/26 (Gr 550)

0.025𝑏𝑤 𝑑 (Gr 420) a)


hc ≥ 𝐴− +
𝑠 or 𝐴𝑠 ≥ max
𝟎. 𝟎𝟐𝟎𝒃𝒘 𝒅 (Gr 550)
b)
− ≥ 2ℎ𝑏
𝑀𝑛1 − c)
𝑀𝑛2 min 2 bars continuous

hb


− +
𝑀𝑛2
+
𝑀𝑛1 𝑀𝑛2 ≥
𝑀𝑛1 ≥ 2
2
max 𝑀𝑛 at either joint
𝑀𝑛+ 𝑜𝑟 𝑀𝑛− at any section ≥
4

WWW.CONCRETE.ORG/ACI318 224
18.6.4.4—Special moment frame beams

• Transverse reinforcement
d/4
hc
s≤ 150 mm
6db (Gr 420), 5db (Gr 550)

𝑠 ≤ 𝑑/2 d/4
≤ 50 𝑚𝑚 s≤ 100 mm

hb

Hoops Hoops @ lap splice


along 2hb Stirrups with seismic hooks

WWW.CONCRETE.ORG/ACI318 225
18.7.5.3 and 18.7.5.5—Columns in special
moment frames

• First hoop at so/2 from the


joint face ℓ /6 clear span ℓo
u
ℓo ≥ [c1, c2]max
450 mm
so
6db,min (Gr 420), 5db,min (Gr 550)
s≤
150 mm
s

6db,min (Gr 420), 5db,min (Gr 550) so ℓo


so ≤ ¼[c1, c2]min
14−ℎ𝑥
4+ , ≤ 150 mm; ≥ 100 mm
3

WWW.CONCRETE.ORG/ACI318 226
18.7.4.3—Bond splitting failure in columns
Moment
Diagram
Splitting can be
controlled by
ℓu Τ2 restricting the
longitudinal bar
size to meet:

ℓu Τ2 1.25ℓd ≤ ℓu/2

Sokoli and Ghannoum (2016)

WWW.CONCRETE.ORG/ACI318 227
18.7.3—Columns of SMF
Mnc
Strong Column/Weak Beam
• Flexural strength check, Beam

18.7.3.2 M Mnb
nb
– ∑Mnc ≥ (6/5)∑Mnb,
– Exception, 18.7.3.1 Column
• Ignore check at top story where
𝑷𝒖 ≤ 𝟎. 𝟏𝑨𝒈 𝒇′𝒄 Mnc

WWW.CONCRETE.ORG/ACI318 228
18.8.4 — Special moment frame beam-column
joints ′
𝑉𝑛 = 𝛾 𝑓𝑐 𝐴𝑗 New in ACI 318-19

 = 20  = 15  = 15  = 12

 = 15  = 12  = 12 =8
Note: Dashed lines show beams either present or absent.
WWW.CONCRETE.ORG/ACI318 229
18.4.3.3—Columns in intermediate moment
frames
• Hoops or spirals required
• First hoop at so/2 from the joint ℓo
face
ℓu /6 clear span
ℓo ≥ [c1, c2]max
450 mm

so ℓ
oo
8db (Gr 420) and 200 mm
so ≤ 6db (Gr 550) and 150 mm
1/2[c1, c2]min

WWW.CONCRETE.ORG/ACI318 230
ACI 318-19
Changes to the Concrete
Design Standard
Special Structural
Walls

WWW.CONCRETE.ORG/ACI318 232
Mu
Ch. 18.10—Special structural wall δu
Pu
Vu
• Cutoff of longitudinal bars
in special boundary
elements
• Reinforcement lap splices
hw
• Reinforcement ratios at Special
ends of walls boundary
element
• Shear demand
• Drift capacity check
• Detailing in special
boundary elements
• Ductile coupled walls ℓw
Shear wall

WWW.CONCRETE.ORG/ACI318 233
18.10.2.3(a)—Longitudinal bar cutoffs

• Previously,
– tension (vertical boundary) reinforcement in
special structural walls to extend 0.8ℓw beyond
the point at which it is no longer required to resist
flexure
• Overly conservative
– This was an approximation of d
– Similar to beams which extend d, 12db and ℓn/16
– These provisions don’t apply well to walls
because of differences in member geometry
and differences in earthquake loadings

WWW.CONCRETE.ORG/ACI318 234
18.10.2.3(a)—Longitudinal bar cutoffs

(a) Except at the top of ℓd


a wall, longitudinal Floor
level
reinforcement shall ≥ 3.6 m
extend at least 3.6 m
above the point at
which it is no longer Bars “a”
required to resist
flexure but need not
extend more than ℓd Bars “a”
no longer
above the next floor required
level. Floor
level

WWW.CONCRETE.ORG/ACI318 235
18.10.2.3(c)—Longitudinal bar lap splices
• Lap splices not
permitted over hsx
above (6.0 m, max)
and ℓd below
critical sections

WWW.CONCRETE.ORG/ACI318 236
18.10.2.4—Minimum longitudinal reinforcement
ratio at ends of walls

hw/ℓw ≥ 2.0

• Failures due to
longitudinal
reinforcement
fracture in tests and
some earthquakes.
El Faro Building, Viña Gallery Apartment:
del Mar, Chile, 1985 Christchurch, 2011
(Photo Credit: Des Bull)

WWW.CONCRETE.ORG/ACI318 237
18.10.2.4—Minimum longitudinal reinforcement
ratio at ends of walls

New ratio
6 f c'
r=
fy
• Many well
distributed cracks
• Flexure yielding
over height
Rick Henry, U. Aukland

WWW.CONCRETE.ORG/ACI318 238
18.10.2.4—Longitudinal reinforcement ratio
at ends of walls

WWW.CONCRETE.ORG/ACI318 240
18.10.2.4—Minimum longitudinal reinforcement
ratio at ends of walls
Walls or wall piers with hw/ℓw ≥ 2.0 must satisfy:

a) Long. reinf. ratio within 0.15 ℓw not less than


6 f c'
r=
fy
b) Long. reinf. extends above and below critical
section the greater of ℓw and Mu/3Vu

c) Max. 50% of reinf. terminated at one section

WWW.CONCRETE.ORG/ACI318 241
18.10.3—Wall shear amplification

• Similar to approach in New Zealand Standard, NZS 3101

WWW.CONCRETE.ORG/ACI318 242
18.10.3—Shear amplification due to overstrength
18.10.3.1.2 – Calculation of Ωv

Table 18.10.3.1.2—Overstrength factor Ωv at critical section


Condition Ωv
Mpr/Mu[1]
hwcs/ℓw > 1.5 Greater of
1.5[2]
hwcs/ℓw ≤ 1.5 1.0

[1] For the load combination producing the largest value of Ωv.
[2] Unless a more detailed analysis demonstrated a smaller value,
but not less than 1.0.

WWW.CONCRETE.ORG/ACI318 243
18.10.3—Shear amplification due to dynamics

18.10.3.1.3 – Calculation of ωv

hwcs/ℓw < 2.0 ➔ ωv = 1.0


hwcs/ℓw ≥ 2.0 ➔ ωv = 0.9 + ns/10 for ns ≤ 6
ωv = 1.3 + ns/30 ≤ 1.8 for ns > 6

where ns ≥ 0.028hwcs

ns = number of stories above the critical section.

WWW.CONCRETE.ORG/ACI318 244
18.10.3—Wall shear amplification
18.10.3.1 The design shear force Ve shall be
calculated by: Ve = v vVu  3Vu

-900 -450 0 450 900


Max/min shear force, V (kN)
GogusGogus
and Wallace, 2015
and Wallace, 2015

WWW.CONCRETE.ORG/ACI318 245
18.10.4.4—Clarification of Acv for walls
No changes to wall shear strength
calculation, except clarification of Acv wall = Acw1+Acw2+Acw3

shear area as:


1 2 3

Acv = gross area of concrete


section bounded by web thickness Acw2
and length of section in the
direction of shear force considered Vertical wall segments
in the case of walls, and gross
area of concrete section in the
case of diaphragms. Gross area is
total area of the defined section
minus area of any openings.

WWW.CONCRETE.ORG/ACI318 248
18.10.6.2—Boundary element confinement
du
(a) Compression zone with special
boundary elements required if:

1.5d u
 w
hwcs 600c hwcs

• c @ [Pu, fMn]max in direction of


design displacement du and Extreme
compression fiber
• du/hwcs ≥ 0.005
Single critical section

WWW.CONCRETE.ORG/ACI318 250
Wall deformation capacity

Segura and Wallace, 2018

𝑙𝑤 𝑐
Stability depends on and .
𝑏 𝑏

Abdulla and Wallace


WWW.CONCRETE.ORG/ACI318 251
18.10.6.2—Displacement based approach

(b) Boundary elements req’d, then (i) and


either (ii) or (iii)
i. Transv. reinf. extends above and below
critical section [ℓw, Mu/4Vu]max

ii. b  0.025 wc

iii. dc/hwcs ≥ 1.5 du / hwcs , where


dc 1  1  w  c  Ve 
=  4 −    −   0.015
hwcs 100  50  b  b  0.66 f c' Acv 
 
WWW.CONCRETE.ORG/ACI318 252
18.10.6.4—Special Boundary Elements
• Single perimeter hoops with 90/135 or 135/135-
degree crossties show inadequate performance

WWW.CONCRETE.ORG/ACI318 253
18.10.6.4(f)—Special Boundary Elements
Longitudinal bars supported
by a seismic hook or corner of
a hoop

smax = 300 mm

WWW.CONCRETE.ORG/ACI318 254
18.10.6.5(b)—If the maximum longitudinal r at
the wall boundary exceeds 400/fy
Table 18.10.6.5b—Maximum vertical spacing of transverse reinforcement at wall boundary
Grade of primary Transverse reinforcement Vertical spacing of transverse reinforcement1
flexural reinforcing required
bar (MPa)
Within the greater of ℓw and 6 db
Mu/4Vu above and below Lesser of:
critical sections2 150 mm
420 8 db
Other locations Lesser of:
200 mm
Within the greater of ℓw and 5 db
Mu/4Vu above and below Lesser of:
critical sections2 150 mm

550 6 db
Other locations Lesser of:
150 mm
Within the greater of ℓw and 4db
Mu/4Vu above and below Lesser of:
critical sections2 150 mm
690 6db
Other locations Lesser of:
150 mm

WWW.CONCRETE.ORG/ACI318 257
18.10.9—Ductile Coupled Walls
Very ductile behavior should ℓw ℓn ℓw
be expected where well-
detailed slender walls are
coupled by ductile coupling
beams aligned over the h
building height.
hwcs

Let’s identify ideal conditions


and define a new structural
system called a Ductile
Coupled Wall.

WWW.CONCRETE.ORG/ACI318 258
18.10.9—Ductile Coupled Walls
• Individual walls satisfy ℓn
ℓw ℓw
– hwcs/ℓw ≥ 2
• All coupling beams must
satisfy:
– ℓn/h ≥ 2 at all levels h
– ℓn/h ≤ 5 at a floor level in at least
90% of the levels of the building
hwcs
– Development into adjacent wall
segments, 1.25fy (18.10.2.5)
• Anticipate new structural
system in ASCE 7 loadings
code.

WWW.CONCRETE.ORG/ACI318 259
ACI 318-19
Cambios en la norma de diseño
del concreto estructural

Cimentaciones

WWW.CONCRETE.ORG/ACI318 260
18.13.4 — Amarres sísmicos de cimentación

CDS C a F
• Amarres sísmicos u otros tipos
CDS D, E o F, con perfiles Clase E o F
• Se requieren amarres sísmicos

Otros tipos, 18.13.4.3


• Vigas de concreto reforzado embebidas dentro
de la losa sobre el terreno
• Losas de concreto reforzado sobre el terreno
• Confinamiento por roca competente, suelos
cohesivos duros o suelos granulares muy densos
• Otros medios aprobados la autoridad competente

WWW.CONCRETE.ORG/ACI318 261
18.13.4.3 — Amarres sísmicos
Fuerza mínima en tracción y Carga de
columna
compresión en el amarre
• Carga desde el cabezal de
pilote o columna
– Mayor en cualquiera de los
extremos Fuerza del
amarre
• 0.1SDS x Carga muerta y
carga viva mayorada por
columna

WWW.CONCRETE.ORG/ACI318 262
18.13.5 — Cimentaciones profundas

• (a) Pilotes de concreto CES sin camisa


metálica, excavados o de tornillo
• (b) Pilotes de concreto con camisa
metálica
• (c) Pilotes de tubo rellenos de concreto
• (d) Pilote prefabricados de concreto

WWW.CONCRETE.ORG/ACI318 263
18.13.5.2 — Cimentaciones profundas

CDS C a F
• Resistencia a las cargas de
tracción
→ Refuerzo longitudinal
continuo en todo su largo para
resistir la fuerza de tracción de
diseño

Fuente: Desarrollos del suelo

WWW.CONCRETE.ORG/ACI318 264
18.13.5.3 — Cimentaciones profundas
Cabezal de pilote
CDS C a F
• Refuerzos transversales
y longitudinales deben
extenderse:
– En toda la longitud al aire,
en agua o tierra suelta no
apoyada lateralmente.

WWW.CONCRETE.ORG/ACI318 265
18.13.5.4 y 18.13.5.5 — Cimentaciones profundas
CDS C a F
• Estribos cerrados de
confinamiento, espirales o
amarres terminan con
ganchos sísmicos D

CDS D, E o F, con perfiles Clase Estratos


blandos
EoF 7D
• Refue. transversal por
columna requerido dentro
de siete diámetros del 7D
miembro Estratos
• ASCE 7, estratos del suelo duros

WWW.CONCRETE.ORG/ACI318 266
18.13.5.6 — Cimentaciones profundas

• CDS D, E o F
– Pilotes, pilas o cajones de
cimentación y amarres de
cimentación que soportan
muros de carga de
aporticamiento ligero de uno
y dos pisos
– Exentos de refu. transv. de
18.13.5.3 a 18.13.5.5

WWW.CONCRETE.ORG/ACI318 267
18.13.5.7 — Pilotes construidos en sitio sin camisa
metálica
CDS C Cabezal
1/3 ℓpile de pilote
•ℓbar ≥ 3m
Amarres o espirales
3dpile
cerrados ≥ n.º 10
Distancia hasta 0.4Mcr > Mu

•Zona de confinamiento
transversal

ℓbar
s
• 3 dpile desde la parte inferior del
cabezal de pilote dpile
• s ≤ 150 mm; 8db barra long.

•Refuerzo transversal extendido rmín. ≥ 0.0025


• s ≤ 16db barra long.
ℓbar = longitud mínima del pilote reforzado
WWW.CONCRETE.ORG/ACI318 268
18.13.5.7 — Pilotes construidos en sitio sin camisa
metálica Cabezal de pilote
CDS D, E o F con perfil Clase A, Amarres cerrados o
B, C y D espirales ≥
n.º 10 (≤ 500 mm) o
1/2 ℓpile
n.º 13 (> 500 mm);
• ℓbar ≥ 3m
18.7.5.2
3dpile
Distancia hasta 0.4Mcr > Mu
•Zona de confinamiento transversal
• 3 dpile desde la parte inferior del
cabezal de pilote

ℓbar
s
• s of 18.7.5.3
• rmin ≥ 0.06 fc′/fyt
dpile
•Refuerzo transversal extendido
12db barra long.
s≤ 0.5dpile rmin ≥ 0.005
300 mm

ℓbar = longitud mínima del pilote reforzado


WWW.CONCRETE.ORG/ACI318 269
18.13.5.7 — Pilotes construidos en sitio sin camisa
metálica Cabezal de pilote
CDS D, E o F con perfil Clase E Amarres cerrados o
yF espirales ≥
n.º 10 (≤ 500 mm) o
•ℓbar Longitud total del pilote n.º 13 (> 500 mm);
(algunas excepciones) 18.7.5.2

•Zona de confinamiento transversal


• 7 dpile desde la parte inferior del
cabezal del pilote

ℓbar
s
• s of 18.7.5.3
• rmin ≥ 0.06 fc′/fyt
dpile
•Refuerzo tranversal extendido
12db barra long. rmin ≥ 0.005
s≤ 0.5dpile
300 mm
ℓbar = longitud mínima del pilote reforzado

WWW.CONCRETE.ORG/ACI318 270
18.13.5.8 —Pilotes de concreto con camisa
metálica Cabezal de
CDS C a F pilote

•Longitudinal igual que los


pilotes sin camisa

•La camisa metálica sustituye


el refuerzo transversal en

ℓbar
pilotes sin camisa
dpile

•Extienda la camisa para ℓbar


t ≥ Calibre 14 (1.7 mm)

WWW.CONCRETE.ORG/ACI318 271
18.13.5.9— Pilotes de tubos rellenos de concreto

ℓcabezal de pilote
Cabezal
CDS C a F
de pilote
•rmin ≥ 0.01

2ℓcabezal de pilote ≥
•ℓd,pile ≥ 2ℓcabezal de pilote
ℓdt,bar

ℓd
dpile

Tubo de acero

WWW.CONCRETE.ORG/ACI318 272
18.13.5.10 — Pilotes prefabricados no
preesforzados Cabezal
de pilote
CDS C Amarres cerrados o
espirales ≥
n.º 10 (≤ 500 mm) o
•ℓbar Longitud total del pilote n.º 13 (> 500 mm);
18.7.5.2
•Zona de confinamiento
transversal
• 3 dpile desde la parte inferior del

ℓbar
s
cabezal de pilote
• s ≤ 150 mm; 8db barra long.
dpile

•Refuerzo transversal
extendido rmin ≥ 0.01
• s ≤ 150 mm

WWW.CONCRETE.ORG/ACI318 273
18.13.5.10 — Pilotes prefabricados no
preesforzados Cabezal
de pilote
CDS D, E o F Amarres cerrados o
espirales ≥
n.º 10 (≤ 500 mm) o
•Igual que CDS C n.º 13 (> 500 mm);
18.7.5.2
•Satisface la Tabla 18.13.5.7.1
para CDS D, E y F

ℓbar
s

dpile

rmin ≥ 0.01

WWW.CONCRETE.ORG/ACI318 274
18.13.5.10 — Pilotes prefabricados
preesforzados
Cabezal
de pilote
CDS C a F
•Satisface 18.13.5.10.4 hasta
18.13.5.10.6
•Cantidad y espaciamiento
mínimos del refuerzo

ℓbar
s
transversal
dpile

WWW.CONCRETE.ORG/ACI318 275
18.13.6 — Anclaje de pilotes, pilas y cajones
de cimentación
CDS C a F
• Cargas de tracción:
trayectoria de carga a
pilotes, pilas o cajones de
cimentación Fuente: Diariocivil

• Transferencia al refuerzo
longitudinal en
cimentación profunda

Fuente: StockQueries

WWW.CONCRETE.ORG/ACI318 276
18.13.6 — Anclaje de pilotes, pilas y cajones
de cimentación tablero

Espigo
18.13.6.2 CDS C a F
ℓd compr.
ℓdt tracción

• Espigo de anclaje entre pilotes y


cabezal de pilote torón

espiral
pilote

18.13.6.3 CDS D a F tabler

• Si fuerzas de tracción y el espigo Espigo


interfaz
postinstalado en el pilote
prefabricado
• Sistema de mortero de inyección torón 1.25fy
Fuente: para desarrollar un mín. de 1.25 espiral
Gayle Johnson pilote
fy (demostrado por el ensayo)
WWW.CONCRETE.ORG/ACI318 277
21.2.4.3—ϕ, Elementos de cimentación

CDS C a F
• Para elementos de cimentación que
soportan el sistema primario de resistencia
ante fuerzas sísmicas
• ϕ para cortante debe ≤ el menor valor de
– ϕ para cortante utilizado para columna especial
– ϕ para cortante utilizado para muro especial

WWW.CONCRETE.ORG/ACI318 278
ACI 318-19
Cambios en la norma de diseño
del concreto estructural
Longitud de
desarrollo

WWW.CONCRETE.ORG/ACI318 279
Longitud de desarrollo

• Barras corrugados y alambres corrugados


en tracción
– Modificación simple al 318S-14
– Aplica los grados 420 y 550

• Ganchos estándar y barras corrugadas con


cabeza
– Cambios sustanciales con respecto a 318S-14

WWW.CONCRETE.ORG/ACI318 280
Longitud de desarrollo

• Barras corrugados y alambres corrugados


en tracción
• Ganchos estándar en tracción
• Barras corrugadas con cabeza en tracción

esfuerzo de adherencia

distribución de las
fuerzas

WWW.CONCRETE.ORG/ACI318 281
Longitud de desarrollo de barras corrugadas y
alambres corrugados en tracción

0 140 280 420 550 700 830 970 1100 1250


0 140 280 420 550 700 830 970 1100 1250
fcalc (MPa)
fcalc (MPa)

Resultados de pruebas no confinadas Resultados de pruebas confinadas

ftest = esfuerzo del refuerzo en el momento de falla


fcalc = tracción calculada resolviendo la ecu. 25.4.2.3a del ACI 318S-14

WWW.CONCRETE.ORG/ACI318 282
Longitud de desarrollo de barras corrugadas
y alambres corrugados en tracción
• Modificaciones
de las
disposiciones
simplificadas de
25.4.2.3
• Ψg : nuevo
factor de
modificación
basado en el
grado de
refuerzo
• Modificación en
la Tabla 25.4.2.3

WWW.CONCRETE.ORG/ACI318 283
Longitud de desarrollo de barras corrugadas
y alambres corrugados en tracción
• Modificación en la ecuación general de la
longitud de desarrollo 25.4.2.4(a)
Factores de modificación
  l : Concreto liviano
  t : Posición de las barras
 fy t e s  g  e : Epóxico
= db s : tamano del refuerzo
d
 1.1l f  cb + K tr  
'
 c
 d  g : Grado del refuerzo
  b 
• Requisito 25.4.2.2
Ktr ≥ 0.5db para fy ≥ 550 MPa , si espaciamiento
longitudinal de la barra < 150 mm

WWW.CONCRETE.ORG/ACI318 284
Longitud de desarrollo de barras corrugadas y
alambres corrugados en tracción

WWW.CONCRETE.ORG/ACI318 285
Longitud de desarrollo de barras corrugadas y
alambres corrugados en tracción

• Diferencias en acero de grados más altos


para concreto de 28 MPa

Grado g ℓd,Gr#/ℓd,Gr60

420 1.0 1.0


550 1.15 1.5
690 1.3 2.2

WWW.CONCRETE.ORG/ACI318 288
Longitud de desarrollo de ganchos estándar
en tracción
• Modos de falla

Extracción Desprendimiento Hendimiento Desprendimiento Desprendimiento


frontal delantero lateral lateral del gancho

• En su mayoría, fallas frontales y laterales


– Falla frontal dominante (extracción por deslizamiento y desprendimiento)
– Desprendimientos fueron más súbitos en naturaleza

WWW.CONCRETE.ORG/ACI318 290
Longitud de desarrollo de ganchos estándar
en tracción

n.º 16
n.º 19
n.º 22 n.º 16
n.º 25 n.º 19
n.º 25
n.º 29 n.º 22
n.º 36 n.º 36
n.º 16 n.º 16
n.º 19
n.º 19 n.º 25
n.º 22 n.º 22
n.º 25 n.º 36

n.º 29
n.º 36
0 35 70 105 140
0 35 70 105 140
Resistencia a la compresión del concreto (MPa)
Resistencia a la compresión del concreto (MPa) Resultados de ensayos
Resultados de ensayos no confinados
confinados

fsu = esfuerzo a la falla del anclaje de la barra con gancho


fs,ACI = esfuerzo estimado por la ec. de longitud de desarrollo del ACI

WWW.CONCRETE.ORG/ACI318 291
Longitud de desarrollo de ganchos estándar en
tracción
- 25.4.3.1—La longitud de desarrollo de los ganchos
estándar en tracción es la mayor entre (a) y (c):

(a)  f y  e r  o c  ACI 318S - 14


=  db1.5  0.24 f y  e c  r 
dh
 23l f ' 
 c  =  db
(b) 8db dh
 
 l fc '

(c) 150 mm

- Factores de modificación
𝝍𝒓 : Confinamiento del refuerzo (redefinición)
𝝍𝒐 : Ubicación (nuevo)
𝝍𝒄 : Resistencia del concreto (nuevo – utilizado como
recubrimiento en el pasado)
WWW.CONCRETE.ORG/ACI318 292
Longitud de desarrollo de ganchos está. en
tracción

318S-14

318-19
WWW.CONCRETE.ORG/ACI318 293
Longitud de desarrollo de ganchos estándar
en tracción

318S-14

318-19

WWW.CONCRETE.ORG/ACI318 297
Longitud de desarrollo de ganchos estándar
en tracción

Factor de Condición Valor del factor


modificación

Resistencia Para f’c < 42 MPa f’c/105 + 0.6


del concreto,
c Para f’c ≥ 42 MPa 1.0

WWW.CONCRETE.ORG/ACI318 298
Ejemplo — Longitud de desarrollo del gancho
estándar
Barras con gancho estándar; f'c = 28 MPa

700

318-14
600
Development Length, ℓdh (mm)

318-19
500

400

300
Barras con gancho estándar; f'c = 40 MPa
200
700
100 318-14
600

Developmet Length, ℓdh (mm)


318-19
0
500
10 15 20 25 30 35 40
Bar Diameter, mm 400

300

200

100

0
10 15 20 25 30 35 40
Bar diameter; mm

WWW.CONCRETE.ORG/ACI318 301
Longitud de desarrollo

• Barras corrugados y alambres corrugados


en tracción
• Ganchos estándar en tracción
• Barras corrugadas con cabeza en tracción

cuña de concreto

fuerza en la barra

fisura de hendimiento
hendimiento radial

WWW.CONCRETE.ORG/ACI318 302
Longitud de desarrollo en tracción de barras
corrugadas con cabeza
25.4.4.1 Se permite el uso de una cabeza para desarrollar
una barra corrugada en tracción si se cumple con las
condiciones (a) a (f):
(a)La barra debe cumplir con 20.2.1.6
(b)El fy de la barra no debe exceder 420 MPa
(b) El tamaño de la barra no debe exceder la No. 36
(c) La superficie de apoyo neta de la cabeza Abrg debe ser al
menos 4Ab
(d) El concreto debe ser de peso normal
(e) El recubrimiento libre de la barra debe ser al menos 2db
(f) Espaciamiento centro a centro entre las barras debe ser
mínimo de 3db

WWW.CONCRETE.ORG/ACI318 303
Longitud de desarrollo de barras corrugadas con
cabeza en tracción

n.º 16a
n.º 16a
n.º 16b
n.º 16b
n.º 25a
n.º 25a
n.º 25b
n.º 25b
n.º 25c
n.º 25c
n.º 36a
n.º 25d
n.º 25d
n.º 36a
n.º 36b
n.º 36b
n.º 36c
n.º 36c
n.º 16a
n.º 16a
n.º 16b
n.º 16b
n.º 25a
n.º 25a
n.º 25b
n.º 25b
n.º 25c
n.º 25c
n.º 36a
n.º 25d
n.º 25d
n.º 36a
n.º 36a
n.º 36b
n.º 36b
0 35 70 105 140 n.º 36c

Resistencia a la compresión del concreto, fcm 0 35 70 105 140


(Mpa) Resistencia a la compresión del concreto, fcm
(Mpa)
Resultados de ensayos no
confinados Resultados de ensayos confinados

fsu = esfuerzo a la falla del anclaje de la barra con cabeza


fs,ACI = esfuerzo estimado por la ec. de longitud de desarrollo del ACI
WWW.CONCRETE.ORG/ACI318 304
Longitud de desarrollo de barras corrugadas
con cabeza en tracción
- 25.4.4.2: La longitud de desarrollo ℓdt para barras
corrugadas con cabeza en tracción debe ser la
mayor de (a) a (c):

(a)

(b) 8db

(c) 150 mm

- Factores de modificación
𝝍𝒑 : Refuerzo de estribos paralelos
𝝍𝒐 : Ubicación
𝝍𝒄 : Resistencia del concreto
WWW.CONCRETE.ORG/ACI318 305
Longitud de desarrollo de barras
corrugadas con cabeza en tracción

WWW.CONCRETE.ORG/ACI318 306
Longitud de desarrollo de barras corrugadas
con cabeza en tracción
• Refuerzo de estribos paralelos (Att)
– localizarlos dentro de 8db de la línea central de la barra
con cabeza hacia el centro del nudo

WWW.CONCRETE.ORG/ACI318 307
ACI 318-19
Changes to the Concrete
Design Standard

Shear Modifications

WWW.CONCRETE.ORG/ACI318 311
ACI 318-19
Changes to the Concrete
Design Standard
One-way Shear
Equations

WWW.CONCRETE.ORG/ACI318 315
317

Why one-way shear equations changed in 318-19


d = 250 mm ls is the size effect factor

Vc = 0.17l f c' bw d

Av  Av ,min

Vtest/Vn = 1

0 500 1000 1500 2000 2500 3000

Depth, d (mm)
Figure: Strength Ratio (Vtest/Vn) that was calculated by 318M-14 Simplified

WWW.CONCRETE.ORG/ACI318 317
Collins, et al., Concrete International, November 2015

WWW.CONCRETE.ORG/ACI318 318
320

Why one-way shear equations changed in 318-19


0.0018 – min. slab rw

Vc = 0.17l f c' bw d

Av  Av ,min

Vtest/Vn = 1

WWW.CONCRETE.ORG/ACI318 320
321

Beams with Av ≥ Av,min

Vc = 0.17l f c' bw d

Av  Av ,min

Vtest/Vn = 1

0 250 500 1000 1500 2000 2500

Depth, d (mm)

WWW.CONCRETE.ORG/ACI318 321
ACI 318-19 New one-way shear equations
Table 22.5.5.1 - Vc for nonprestressed members
Criteria Vc

𝑁𝑢
0.17𝜆 𝑓′𝑐 + 𝑏𝑤 𝑑 (a)
Either 6𝐴𝑔
Av ≥ Av,min
of: 1Τ3
𝑁𝑢
0.66𝜆 𝜌𝑤 𝑓′𝑐 + 𝑏𝑤 𝑑 (b)
6𝐴𝑔

1Τ3
𝑁𝑢
Av < Av,min 0.66𝜆𝑠 𝜆 𝜌𝑤 𝑓′𝑐 + 𝑏𝑤 𝑑 (c)
6𝐴𝑔
Notes:
1. Axial load, Nu, is positive for compression and negative for tension
2. Vc shall not be taken less than zero.

WWW.CONCRETE.ORG/ACI318 326
Size effect – what is ls? 2
ls =  1.0
1 + 0.004d
1.2

0.8
λs

0.6

0.4

0.2

0
0 12
300 24
600 36
900 48
1200 60
1500 72
1800 84 96 2700
2100 2400 108 3000
120
Depth
Depth inin mm
inches
WWW.CONCRETE.ORG/ACI318 329
ACI 318-19 New one-way shear equations
Table 22.5.5.1 - Vc for nonprestressed members
Criteria Vc

𝑁𝑢
0.17𝜆 𝑓′𝑐 + 𝑏𝑤 𝑑 (a)
Either 6𝐴𝑔
Av ≥ Av,min
of: 1Τ3
𝑁𝑢
0.66𝜆 𝜌𝑤 𝑓′𝑐 + 𝑏𝑤 𝑑 (b)
6𝐴𝑔

1Τ3
𝑁𝑢
Av < Av,min 0.66𝜆𝑠 𝜆 𝜌𝑤 𝑓′𝑐 + 𝑏𝑤 𝑑 (c)
6𝐴𝑔
Notes:
1. Axial load, Nu, is positive for compression and negative for tension
2. Vc shall not be taken less than zero.

WWW.CONCRETE.ORG/ACI318 330
Other limitations for Table 22.5.5.1

• Provision 22.5.5.1.1:
– Limits the maximum value of Vc
Vc  0.42l f c' bw d
• Provision 22.5.5.1.2:
– Limits the maximum value of the Nu/6Ag term
Nu
 0.05 f c'
6 Ag

WWW.CONCRETE.ORG/ACI318 331
RC Beams without shear reinforcement

ACI 318-14 ACI 318-19


1/3 𝑁𝑢
𝑉𝑛 = 2𝜆 𝑓𝑐′ 𝑏𝑤 𝑑 𝑉𝑛 = 8𝜆𝑠 𝜆𝜌𝑤 𝑓𝑐′ + 𝑏 𝑑
6𝐴𝑔 𝑤
3.0 3.0
Satisfies ACI 318
2.5 criteria 2.5
Does not satisfy
Vtest/Vn

Vtest/Vn
2.0 ACI 318 criteria 2.0
1.5 1.5
1.0 1.0
0.5 0.5
0.0 0.0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Depth, mm Depth, mm

Kuchma et al., ACI Str. J., July 2019

WWW.CONCRETE.ORG/ACI318 332
Key points in application of new equations

• Only applicable to non-prestressed


members.
• Minimal effect for members having Av,min.
• For members without Av,min, the more
complicated equation is required.
• For foundation elements, the size effect
term can always be taken as ls = 1.0.

WWW.CONCRETE.ORG/ACI318 337
Examples: SP-17(14) 5.7 One-way slab Example 1

• Span = 4.3 m
• Live load = 490 kg/m2
• Slab = 175 mm thick
• f’c = 35 MPa
• No. 16 bars at 300 mm
• d ~ 150 mm
• b = 300 mm
• Av = 0 mm2
• As = 632 mm2/ft
• Vu= 35 kN/m
WWW.CONCRETE.ORG/ACI318 338
Examples: SP-17(14) 5.7 One-way slab Example 1

• SP-17(14) One-way shear calc ACIM 318-14

fVc = f0.17l f c' bd


fVc = (0.75)(0.17)(1) 28
35 MPa
MPa (1000 mm)(150 mm)
fVc = 101.2
113 kNkN  35.0 kN  OK

WWW.CONCRETE.ORG/ACI318 339
Examples: SP-17(14) 5.7 One-way slab Example 1

• SP-17(14) One-way shear calc ACI 318-19


• Av ≤ Av,min, therefore use Eq. 22.5.5.1(c)
1
fVc = f0.66l s l (r w ) 3 '
f bd
c

653
rw = = 0.0044  low r w
(1000)(150)
fVc = (0.75)(0.66)(1)(1) ( 0.0044 )
1
3
28(1000)(150)
35(1000)(150)
fVc = 64.4
72 kNkN  35 kN  OK
WWW.CONCRETE.ORG/ACI318 340
Examples: SP-17(14) 11.6 Foundation Example 1
• ℓ = 3.6 m
• h = 750 mm
• d ~ 650 mm 500 mm x 500 mm

• f’c = 28 MPa 150 mm basement slab

• 13-No. 25 bars

0 in.
ft –mm
• b = 3.6 m

3900
• Av = 0 mm2
• As = 6630 mm2
• Analysis Vu= 1028 kN

WWW.CONCRETE.ORG/ACI318 342
Examples: SP-17(14) 11.6 Foundation Example 1

• SP-17(14) One-way shear calc ACI 318M-14

fVc = f0.17l f bd c
'

fVc = (0.75)(0.17)(1) 28 MPa (3600 mm)(650 mm)


fVc = 1579 kN  1028 kN  OK

WWW.CONCRETE.ORG/ACI318 343
Examples: SP-17(14) 11.6 Foundation Example 1
• SP-17(14) One-way shear calc ACI 318-19
• Av ≤ Av,min, Eq. 22.5.5.1(c)
• Per ACI 318-19 (13.2.6.2), neglect size effect
for:
– One-way shallow foundations
– Two-way isolated footings
– Two-way combined and mat foundations

1
fVc = f0.66l (r w ) 3 '
f bd
c

WWW.CONCRETE.ORG/ACI318 344
Examples: SP-17(14) 11.6 Foundation Example 1
• SP-17(14) One-way shear calc ACI 318-19
• Av ≤ Av,min, Eq. 22.5.5.1(c)

1
fVc = f0.66l (r w ) 3
f c' bd
6630 mm 2
rw = = 0.0028
(3600 mm)(650 mm)
fVc = (0.75)(0.66)(1) ( 0.0028 )
1
3
28 MPa (3600 mm)(650 mm)
fVc = 864 kN  1028 kN  NG No good

WWW.CONCRETE.ORG/ACI318 345
ACI 318-19
Changes to the Concrete
Design Standard
Two-way Shear
Equations

WWW.CONCRETE.ORG/ACI318 350
Two-way shear size effect

• Table 22.6.5.2 — vc for two-way members


without shear reinforcement
vc where
0.33l s l f c' (a)
2
 2 ls = 1
0.17  1 +  l s l f c' (b) 1 + 0.004d
Least of (a), (b),  
and (c):

 sd 
0.083  2 + l
 s l f c
'
(c)
 bo 

WWW.CONCRETE.ORG/ACI318 352
Two-way shear low r effect
• D, L only, cracking ~0. 𝟏𝟕 𝒇′𝒄 ; punching
0. 𝟑𝟑 𝒇′𝒄
• Aggregate interlock
• Low r ➔ bar yielding, ↑ rotation, ↑crack
size, allows sliding of reinforcement
• Punching loads < 0. 𝟑𝟑 𝒇′𝒄

Source: Performance and design of punching –


shear reinforcing system, Ruiz et al, fib 2010

WWW.CONCRETE.ORG/ACI318 353
New two-way slab reinforcement limits
8.6.1—Reinforcement limits

• As,min ≥ 0.0018Ag

• If vuv  f0.17l s l on the critical section


'
f c

0.42vuvbslabbo
• Then As ,min 
f s f y

WWW.CONCRETE.ORG/ACI318 354
ACI 318-19
Changes to the Concrete
Design Standard

Wall Shear Equations

WWW.CONCRETE.ORG/ACI318 358
Coordination of Chap. 11 and 18 Wall Shear Eqs.

• 318M-14 • 318M-19
– Chapter 11 – Chapter 11
𝐴𝑣 𝑓𝑦𝑡 𝑑
𝑉𝑛 = 0.17𝜆 𝑓𝑐′ ℎ𝑑 + 𝑉𝑛 = 𝛼𝑐 𝜆 𝑓𝑐′ + 𝜌𝑡 𝑓𝑦𝑡 𝐴𝑐𝑣
𝑠

– Chapter 18 – Chapter 18

𝑉𝑛 = 𝛼𝑐 𝜆 𝑓𝑐′ + 𝜌𝑡 𝑓𝑦𝑡 𝐴𝑐𝑣 𝑉𝑛 = 𝛼𝑐 𝜆 𝑓𝑐′ + 𝜌𝑡 𝑓𝑦𝑡 𝐴𝑐𝑣

WWW.CONCRETE.ORG/ACI318 360
Coordination of Chap. 11 and 18 Wall Shear Eqs.
• 318-19 Eq. 11.5.4.3 and Eq. 18.10.4.1
( )
Vn =  c l f c' + rt f yt Acv

0.25
0.17

WWW.CONCRETE.ORG/ACI318 361
Coordination of Chap. 11 and 18 Wall Shear Eqs.
• Maximum permissible shear
– 318-14: 𝑽𝒏 ≤ 𝟎. 𝟖𝟑 𝒇′𝒄 𝑨𝒄𝒗 where typically 𝑨𝒄𝒗 = 𝟎. 𝟖ℓ𝒘 𝒉
– 318-19: 𝑽𝒏 ≤ 0.67 𝒇′𝒄 𝑨𝒄𝒗 where typically 𝑨𝒄𝒗 = ℓ𝒘 𝒉
• Net result: Maximum permissible shear
essentially the same in Chapter 11 of ACI 318-
14 and ACI 318-19

WWW.CONCRETE.ORG/ACI318 362
ACI 318-19
Changes to the Concrete
Design Standard
Spacing of Shear
Reinforcement

WWW.CONCRETE.ORG/ACI318 363
Maximum spacing of legs of shear reinforcement

Source: Lubell et. al, “Shear Reinforcement Spacing in Wide Members, ACI Structural Journal 2009

WWW.CONCRETE.ORG/ACI318 364
Table 9.7.6.2.2—Maximum spacing of legs of
shear reinforcement

Maximum s, mm
Nonprestressed beam Prestressed beam
Required Vs
Across Along Across
Along length
length length length
d/2 d 3h/4 3h/2
 0.33 f b d'
c w
Lesser of:
600 mm
d/4 d/2 3h/8 3h/4
 0.33 f b d'
c w Lesser of
300 mm

WWW.CONCRETE.ORG/ACI318 365
Maximum spacing of legs of shear reinforcement

Example stirrup layout

Beam stirrup configuration with three


closed stirrups distributed across the beam
width
Single U-stirrup (with 135-degree hooks)
across the net width of the beam, two
identical U-stirrups
s maximum = d or d/2 nonprestressed, (eachprestressed
3h/2 or 3h/4 with 135-degree
hooks) distributed across the beam interior,
and a stirrup cap
s maximum = d or d/2 nonprestressed, 3h/2 or 3h/4 prestressed
Single U-stirrup across the net width of the
beam, two smaller-width U-stirrups nested in
the beam interior, and a stirrup cap

s maximum = d or d/2 nonprestressed, 3h/2 or 3h/4 prestressed


WWW.CONCRETE.ORG/ACI318 366
ACI 318-19
Changes to the Concrete
Design Standard

Bi-directional Shear

WWW.CONCRETE.ORG/ACI318 367
Interaction of shear forces

• Biaxial shear
• Symmetrical RC circular sections
– fVn equal about any axis (assuming constant Nu).
– Vu on 2 centroidal axes, Vu = resultant

vu = (vu , x ) + (vu , y )
2 2 vu,y

vu,x

WWW.CONCRETE.ORG/ACI318 368
Interaction of shear forces

• Biaxial shear
• Rectangular RC sections
– fVn differs between axes
– Vu on 2 axes, strength along
resultant unclear.

vu,y
vu,x
vu

WWW.CONCRETE.ORG/ACI318 369
2.5

Interaction of shear forces


Interaction C
N>0
2 N=0
• Approximately elliptical N<0
interaction diagram.

Vexp(y)/Vpre(y)
1.5

• 22.5.1.10 Neglect interaction if


vu,x/fvn,x ≤ 0.5, or vu,y/fvn,y ≤ 0.5 1

• 22.5.1.11 Design for interaction if 0.5


vu,x/fvn,x > 0.5, and vu,y/fvn,y > 0.5
0
0 0.5 1 1.5
𝑣𝑢,𝑥 𝑣𝑢,𝑦 Vexp(x)/Vpre(x)
+ ≤ 1.5
𝜙𝑣𝑛,𝑥 𝜙𝑣𝑛,𝑦

WWW.CONCRETE.ORG/ACI318 370
ACI 318-19
Changes to the Concrete
Design Standard
Hanger
Reinforcement

WWW.CONCRETE.ORG/ACI318 372
Monolithic beam-to-beam joints: Hanger steel

WWW.CONCRETE.ORG/ACI318 373
Monolithic beam-to-beam joints: Hanger steel

• Commentary added: R9.7.6.2


• Hanger reinforcement
– Suggested where both the following are true:
– Beam depth ≥ 0.5 girder depth
– Stress transmitted from beam to girder ≥ 0.25√f’c of
the beam

WWW.CONCRETE.ORG/ACI318 374
ACI 318-19
Cambios en la norma de diseño
de concreto estructural

Durabilidad y materiales del concreto

WWW.CONCRETE.ORG/ACI318 375
Cambios en la durabilidad y los materiales
• Cambios en las propiedades de los materiales (19.2)
– Requisitos mínimos adicionales de f’c
– Requisitos del Ec
• Cambios en la durabilidad (19.3)
– Cálculo del contenido de iones de cloruro
– Categoría de exposición a los sulfatos S3
– Categoría de exposición al agua W
– Categoría de exposición a la corrosión C0
• Cambios en el material (26.4.1)
– Cementos alternativos
– Agregados nuevos
• Agregados reciclados
• Adiciones minerales
• Evaluación y aceptación (26.12)
– Ensayos de resistencia
• Inspección (26.13)

WWW.CONCRETE.ORG/ACI318 376
Tabla 19.2.1.1 —
Resistencia mínima adicional, f'c
Mín. f’c
Muros estructurales en CDS D, E y F (MPa)
Muros estructurales especiales con refuerzo Grado 690 35

Concreto de mayor resistencia utilizado con acero de


mayor resistencia

• Mejora el anclaje de la barra

• Reduce la profundidad del eje neutro para mejorar


el desempeño
WWW.CONCRETE.ORG/ACI318 377
19.2.2.1R Módulo de elasticidad

• Ec de las ecuaciones del reglamento es


apropiado para la mayoría de las
aplicaciones

• Grandes diferencias para concreto de alta


resistencia (f′c > 56 MPa), concreto liviano,
y mezclas con bajo volumen de agregado
grueso

WWW.CONCRETE.ORG/ACI318 378
19.2.2.2 Módulo de elasticidad
Ec puede especificarse con base
en ensayos de mezclas de
concreto:

a) Utilización del EC especificado


para la dosificación de la
mezcla de concreto
b) Ensayos del EC especificado
c) Ensayos de EC a los 28 días o
como se indique en los
documentos de construcción

WWW.CONCRETE.ORG/ACI318 Fuente: Engineering discoveries 379


Ataque de sulfato — Cambio en S3

Crédito:
PCA
WWW.CONCRETE.ORG/ACI318 384
Nuevos materiales permitidos

• Cementos alternativos (26.4.1.1) Cortesía: PCA

– Cementos inorgánicos utilizados como


sustitución al 100% de cemento portland
– Vidrio reciclado y otros en ACI ITG-10

• Agregados y adiciones minerales


alternativas (26.4.1.2 y 3)
– Agregado reciclado de concreto triturado
– Adiciones minerales — vidrio reciclado
finamente molido u otras

WWW.CONCRETE.ORG/ACI318 391
Nuevos materiales permitidos

Permitido si: Cortesía: PCA

• Datos documentados de ensayos confirmen


las propiedades mecánicas para el diseño del
concreto estructural se cumplen (resistencia,
durabilidad, resistencia al fuego)
• Aprobado por el profesional facultado para
diseñar y la autoridad competente
• Programa de ensayos durante la duración del
proyecto y programa de control de calidad
(agregados reciclados alternativos) para
lograr lo requerido de las propiedades del
concreto

WWW.CONCRETE.ORG/ACI318 392
26.12 — Evaluación y aceptación de
concreto endurecido
• 26.12.1.1
– Normas de ASTM añadidas para muestreo, cilindros
y ensayos
– Muestras tomadas en el punto de entrega
– Certificación requerida de los técnicos en ensayos
en la obra y en el laboratorio
– Se aclaró que un "ensayo de resistencia"
corresponde al promedio de al menos dos cilindros
de 150 x 300 mm o tres cilindros de 100 x 200 mm

WWW.CONCRETE.ORG/ACI318 394
26.12.6 Investigación de los ensayos de
resistencia
(d) Ensayo de núcleos:
• Mín. 5 días después de haberse humedecido
• Máx. 7 días después de haber sido extraídos
A menos que sea aprobado de otra manera
por el profesional facultado para diseñar o la
autoridad competente

Fuente: The Constructor


WWW.CONCRETE.ORG/ACI318 395
26.13 — Inspección

El inspector debe estar certificado cuando


inspeccione:
• Cimbras y encofrados,
• Colocación del concreto,
• Refuerzo,
• Insertos embebidos

WWW.CONCRETE.ORG/ACI318 Foto: cortesía de Larry Novak 398


Otras inspecciones (26.13.1)

• Soldadura del refuerzo → inspector de


soldadura calificado
• Anclajes de expansión, de tornillo y de
sobreperforación en su base → inspector
certificado o aprobado por profesional
facultado para diseñar y la autoridad
competente
• Anclajes adheridos → inspector certificado

WWW.CONCRETE.ORG/ACI318 400
ACI 318-19
Changes to the Concrete
Design Standard

Strut-and-Tie Method

WWW.CONCRETE.ORG/ACI318 404
Why strut-and-tie method?

• Valuable tool where plane-sections


assumption of beam theory does not apply
• Truss analogy used to analyze concrete
structures

WWW.CONCRETE.ORG/ACI318 405
Strut and Tie Method

WWW.CONCRETE.ORG/ACI318 406
Deletion of bottle-shaped strut
Bottle-shaped strut
• Concentrated load spreads out at a slope of 2:1
• Leads to splitting stress, which weakens strut
• Actual behavior in a shear span more complicated.
• Bottle-shaped strut concept dropped in ACI 318-19

WWW.CONCRETE.ORG/ACI318 407
23.4 Strength of struts

• 3 components
– Struts
– Ties
– Nodal zones

Strut strength:
Fns = fce Acs + A’s f’s
and
fce = 0.85csf’c

WWW.CONCRETE.ORG/ACI318 408
23.4 Strength of struts
Strut coefficient, βs → Table 23.4.3
Strut location Strut type Criteria s
Tension members or
tension zones of Any All cases 0.4 (a)
members
Boundary
All cases 1.0 (b)
strut
Reinforcement satisfying (a)
0.75 (c)
All other cases or (b) of Table 23.5.1
Interior 𝑽𝒖 ≤ 𝝓(𝟎. 𝟒𝟑)𝝀𝝀𝒔 𝒇′𝒄 𝒃𝒘 𝒅 𝐭𝐚𝐧 𝜽 0.75 (d)
struts
Beam-column joints 0.75 (e)
All other cases 0.4 (f)

WWW.CONCRETE.ORG/ACI318 409
Minimum Reinforcement of D Regions

3.5

3
Strength Ratio (Vtest/Vstm)

2.5

1.5

0.5
0.25%
0
0 0.002 0.004 0.006 0.008 0.01

Minimum (Vert. & Hor.) Distributed Reinforcement Ratio


WWW.CONCRETE.ORG/ACI318 410
23.5 Minimum distributed reinforcement

Table 23.5.1—Minimum distributed reinforcement *


Reinforcement Minimum distributed
configuration reinforcement ratio
Orthogonal grid 0.0025 in each direction (a)**
Reinforcement in one
direction crossing strut 0.0025/(sin2i) (b)**
at angle i

* Not all of Table 23.5.1

** 9.9.3.1 & 9.9.4.3 requires that deep beams be reinforced per (a).
23.5.1 requires all other components be reinforced per (a) or (b),
except where the strut is laterally constrained by concrete.

WWW.CONCRETE.ORG/ACI318 411
23.5 What is a laterally-restrained strut?
a) Discontinuity region is continuous ┴ to plane of
the strut-and-tie model.

Discontinuity Region

WWW.CONCRETE.ORG/ACI318 412
23.5 What is a laterally-restrained strut?
b) Concrete restraining strut extends beyond
each side face of strut a dist. ≥ 1/2 ws

Source: Yun et al. 2016


WWW.CONCRETE.ORG/ACI318 413
23.5 What is a laterally-restrained strut?
c) Strut in a joint restrained on all 4 faces (15.2.5 &
15.2.6)

WWW.CONCRETE.ORG/ACI318 414
23.4 Strength of struts
Strut coefficient, βs → Table 23.4.3
Strut location Strut type Criteria s
Tension members or
tension zones of Any All cases 0.4 (a)
members
Boundary
All cases 1.0 (b)
strut
Reinforcement satisfying (a)
0.75 (c)
All other cases or (b) of Table 23.5.1
Interior 𝑽𝒖 ≤ 𝝓(𝟎. 𝟒𝟑)𝝀𝝀𝒔 𝒇′𝒄 𝒃𝒘 𝒅 𝐭𝐚𝐧 𝜽 0.75 (d)
struts
Beam-column joints 0.75 (e)
All other cases 0.4 (f)

WWW.CONCRETE.ORG/ACI318 415
23.2.8 Effect of Prestressing
1600

12-13 Strand
1140
1187 mm2 110
1233 kN

1820 1820

1600

800 800
800
800

430 369 430


1233 kN 1233 kN

800 800
910 910 910 910

WWW.CONCRETE.ORG/ACI318 422
23.2.8 Effect of Prestressing in STM

• Use as an external load


• Prestress force applied at end of strand
transfer length
• Load factors per 5.3.13
– LF of 1.2 if PT effects increase net force in struts or
ties
– LF of 0.9 if PT reduce net force in struts or ties

WWW.CONCRETE.ORG/ACI318 423
23.7 Strength of ties

Tensile strength:
– Simple tension element
– Fnt = Atsfy +AtpDfp
– f = 0.75 for all ties
• Atp = 0 (nonprestressed)
• Δfp = 420 MPa for bonded prestressed reinf. and
70 MPa for unbonded prestressed reinf.
• T Δfp,max = fpy - fse
Note: tie centroid coincides with reinforcement centroid

WWW.CONCRETE.ORG/ACI318 424
23.10 Curved-bar Nodes

Why curved nodes?

Nodal zones are often


too small to allow
development

WWW.CONCRETE.ORG/ACI318 438
23.10 Curved-bar Nodes
C-T-T
q < 180 degree bend T

2 Ats fy C
rb  '
bf s c

but not less than half bend T C


diameter of Table 25.3

WWW.CONCRETE.ORG/ACI318 442
23.10 Curved-bar Nodes
23.10.6 The curve must be
sufficient to develop
difference in force

ℓcb > ℓd(1 – tan θc)

In terms of rb
2 d (1 − tan qc ) d b
rb  −
 2
WWW.CONCRETE.ORG/ACI318 447
23.11 Earthquake-resistant design using STM

Distributor/Collector Compression strut Tension tie

Develop tension tie


beyond node Basement wall

Wall Transfer
a b force e f

Opening

d c h g

WWW.CONCRETE.ORG/ACI318 449
Earthquake-resistant design using STM

Seismic-force-resisting system assigned to


SDC D-F and designed with STM must satisfy:

1. Chapter 18

2. Strut forces are increased by overstrength


factor Ωo = 2.5 or Ωo < 2.5 if based on
rational analysis

WWW.CONCRETE.ORG/ACI318 450
23.11 Earthquake-resistant design using STM

If condition 2 is not satisfied then the following


must be addressed, Provisions 23.11.2 - 23.11.5
1. Provisions 23.11.2 and 23.11.5
Reduce strut and node effective
compressive strength, fce, of concrete by 0.8
fce = (0.8)(0.85 βcβs/n fc′)

WWW.CONCRETE.ORG/ACI318 451
23.11 Earthquake-resistant design using STM

2. Two options for strut detailing,


Provisions 23.11.3 and 23.11.4:

• Strut w/min. 4 bars


• Transverse ties perpendicular to strut
• Detailing of ties per Ch. 18 column
requirements and Ch. 23 Tables
23.11.3.2 and 23.11.3.3 Section A-A

WWW.CONCRETE.ORG/ACI318 452
ACI 318-19
Cambios en la norma de diseño
de concreto estructural

Concreto lanzado

WWW.CONCRETE.ORG/ACI318 454
Concreto lanzado
• Concreto lanzado
es igual al
concreto normal
• Método de
colocación
• Información
adicional en ACI
506R y ACI 506.2

WWW.CONCRETE.ORG/ACI318 455
Concreto lanzado

¿Por qué concreto lanzado?


• Varias aplicaciones — nuevas o reparación
• Económico
• Efectivo
• Excelente adherencia

WWW.CONCRETE.ORG/ACI318 456
Concreto lanzado

Dos procesos
• Mezcla húmeda
• Mezcla seca

WWW.CONCRETE.ORG/ACI318 457
Concreto lanzado — Espaciamiento mínimo
del refuerzo
• 25.2.10
– Para estribos, estribos cerrados de confinamiento, y
refuerzos en espiral en columnas a ser colocadas
con concreto lanzado, el mínimo espaciamiento
libre será de 75 mm.

≥ 75 mm

WWW.CONCRETE.ORG/ACI318 460
Concreto lanzado

Paneles de pruebas

• Para demostrar el embebido adecuado del


refuerzo

• Deben representar las configuraciones del


refuerzo más complejas

WWW.CONCRETE.ORG/ACI318 462
Concreto lanzado

• Paneles de prueba

Panel de prueba El personal lanzando el


panel de pruebas

WWW.CONCRETE.ORG/ACI318 463
Concreto lanzado

Documentos de construcción e inspección


• 26.3.1-26.3.2: Donde se requiera concreto
lanzado
– Identificar los miembros que se van a construir con
concreto lanzado
• 26.4.1.2 – 26.4.1.7: Materiales
– Gradación del agregado — norma ASTM C1436.
– Aditivos — norma ASTM C1141M.
– Materiales preempacados, premezclados, secos,
combinados para concreto lanzado — norma
ASTM C1480M

WWW.CONCRETE.ORG/ACI318 464
Concreto lanzado

• 26.4.2 — Requisitos de la mezcla de concreto


– Tamaño máximo de agregados gruesos ≤ 13 mm

WWW.CONCRETE.ORG/ACI318 465
Concreto lanzado
26.5.6: Construcción, juntas de construcción,
contracción y dilatación
• corte a 45° a menos que se designe una junta
a escuadra
• Remitir las ubicaciones al profesional
facultado para diseñar para su aprobación
– Para juntas no indicadas en los documentos de
construcción

WWW.CONCRETE.ORG/ACI318 470
Concreto lanzado
26.12 — Evaluación y 150 mm

aceptación
• Prueba de resistencia
– Resistencia media de un
mínimo de tres núcleos
de 75 mm de diámetro
de un panel de prueba 300 mm 450 mm

– Ensayados a los 28 días


o a la edad de prueba
designada para fc′
Refuerzo electrosoldado
75 mm de alambre de 13 mm

Esquema del panel de prueba de material


que muestre dónde cortar cinco núcleos
WWW.CONCRETE.ORG/ACI318 471
ACI 318-19
Cambios en la norma de diseño
de concreto estructural
Verificación de diseño
mediante análisis
dinámico no lineal

WWW.CONCRETE.ORG/ACI318 475
Nuevo en el ACI 318-19
• Nuevo Apéndice A sobre
análisis dinámico no lineal de
estructuras de concreto
reforzado, para la aplicación
del ASCE 7-16, el TBI (versión
2.0 de 2017) y el Los Angeles
Tall Buildings Design
Procedure (2017).

WWW.CONCRETE.ORG/ACI318 484
Nuevo en el ACI 318-19
• Nuevo Apéndice A sobre
análisis dinámico no lineal de
estructuras de concreto
reforzado, para la aplicación
del ASCE 7-16, el TBI (versión
2.0 de 2017) y el Los Angeles
Tall Buildings Design
Procedure (2017).

WWW.CONCRETE.ORG/ACI318 485
WWW.CONCRETE.ORG/ACI318 486
WWW.CONCRETE.ORG/ACI318 487
Contenido del nuevo
Apéndice A
A.1 — Nomenclatura y terminología
A.2 — Alcance
A.3 — Generalidades
A.4 — Movimientos sísmicos del terreno
A.5 — Factores y combinaciones de carga
A.6 — Modelaje y análisis
A.7 — Clasificación de las acciones y sus
condiciones críticas
A.8 — Rigidez efectiva

WWW.CONCRETE.ORG/ACI318 488
Contenido del nuevo
Apéndice A
A.9 — Resistencia de los materiales esperada
A.10 — Criterio de aceptación para acciones
controladas por deformación
A.11 — Resistencia esperada para acciones
controladas por fuerza
A.12 — Requisitos de detallado mejorados
A.13 — Revisión independiente del diseño
estructural

WWW.CONCRETE.ORG/ACI318 489
Alcance

WWW.CONCRETE.ORG/ACI318 490
Seleccion y modificacion de los
movimientos sísmicos del terreno

GeoPentech

WWW.CONCRETE.ORG/ACI318 491
Nivel de servicio y máximo
considerado (MCER)
3.5
Pseudo Spectral Acceleration, g

3.0
Maximum Considered Shaking (MCER)
2.5 (1000 to 2500-yr return period)

2.0

1.5
Service Level Earthquake (SLE)
1.0 (43-yr return period)

0.5

0.0
0 2 4 6 8 10
Period, sec

WWW.CONCRETE.ORG/ACI318 492
Fluencia objetivo Modelaje estructural

Coupling Beam Yielding – Permitted

Wall Flexural Yielding – Permitted


Web Shear - Protected

Transfer Diaphragms - Protected

Reinforced Concrete Coupled


Wall Structural System

WWW.CONCRETE.ORG/ACI318 493
Modelaje de acciones controladas
por deformación

MKA

WWW.CONCRETE.ORG/ACI318 494
Criterio de aceptacion - SLE
Story drift ratio ≤ 0.005

Effectively linear response

Elevation

WWW.CONCRETE.ORG/ACI318 495
Criterio de aceptación - MCER
Mean transient story drift ratio ≤ 0.03 (Max ≤ 0.045)
Mean residual story drift ratio ≤ 0.01 (Max ≤ 0.015)

Deformation-controlled actions (e.g., coupling


beam rotations) within modeling limits.

Strains within modeling limits.


Force-controlled actions (e.g., wall shear)
satisfies load combination.

Elevation

1.2 + 0.12𝑆𝑀𝑆 𝐷 + 1.0 𝑜𝑟 0.5 𝐿 + 𝛾𝐸 𝐸 ≤ 𝜙𝑅𝑛


0.9 − 0.12𝑆𝑀𝑆 𝐷 − 𝛾𝐸 𝐸 ≤ 𝜙𝑅𝑛

WWW.CONCRETE.ORG/ACI318 496
Estadistica de las demandas

Assumed Variability and Uncertainty Values for


Component Force Demand

Value Source

0.3 Record-to-record variability

Uncertainty from estimating


0.2
force demands using structural
model
Variability from estimating force
0.09
demands from mean of only 11 ground
motions
0.37 Total demand uncertainty 𝛾𝐸 𝑉𝑢 /𝐴𝑐𝑣 𝑓𝑐′

WWW.CONCRETE.ORG/ACI318 497
Ecuaciones finales de factores de carga y
resistencia

1.2 + 0.12𝑆𝑀𝑆 𝐷 + 1.0 𝑜𝑟 0.5 𝐿 + 1.3𝐼𝑒 𝐸 ≤ 𝜙𝑅𝑛


0.9 − 0.12𝑆𝑀𝑆 𝐷 − 1.3𝐼𝑒 𝐸 ≤ 𝜙𝑅𝑛

Left to the materials standards


Risk Categories and Target Reliabilities (Conditional (See, for example, ACI 318-19)
Probability of Failure) Given MCER Shaking
Target Reliabilities
Risk Category Ie
ASCE 7-16 TBI 2017

I & II 1.0 10% 10%

III 1.25 5% 3%

IV 1.5 2.5% 1%

TBI 2017

WWW.CONCRETE.ORG/ACI318 498
Verificacion de desempeño:
Cortante en el núcleo

(psi)
0 0.5 1.0 (MPa)

MKA

WWW.CONCRETE.ORG/ACI318 499
Verificación de desempeño: Deformaciones
unitarias loigtudinales en la pared del núcleo

0.0000
MKA Compression Tension

WWW.CONCRETE.ORG/ACI318 500
WWW.CONCRETE.ORG/ACI318 501
Algunos resultados típicos

Limit

Limit

Limit
Height, ft

Height, ft

Height, ft
SLE story drift Max of mean MCER transient Max of mean MCER residual
ratio story drift ratio story drift ratio

WWW.CONCRETE.ORG/ACI318 502
Algunos resultados típicos

Limit
Height, ft

Limit
Height, ft
Max of mean MCER wall tensile
strain
Limit
Height, ft

Max of 1.3 x mean MCER wall shear / 𝑓𝑐′ 𝐴𝑤 , psi

Max of mean MCER wall compressive strain

WWW.CONCRETE.ORG/ACI318 503
OTROS ASPECTOS
IMPORTANTES

WWW.CONCRETE.ORG/ACI318 504
El %

¡La nueva
ingeniería
estructural!

WWW.CONCRETE.ORG/ACI318 505
Basta buscar la tecla

WWW.CONCRETE.ORG/ACI318 506
Es fácil

WWW.CONCRETE.ORG/ACI318 507
Oprimimos

WWW.CONCRETE.ORG/ACI318 508
… y podemos pasar
de datos a planos
sin que los revise
un humano!
WWW.CONCRETE.ORG/ACI318 509
¡Que susto!
Quedamos
fríos
WWW.CONCRETE.ORG/ACI318 510
Fin

WWW.CONCRETE.ORG/ACI318 511
ACI 318-19
Changes to the Concrete
Design Standard

Closing Remarks

WWW.CONCRETE.ORG/ACI318 512
An Invitation to Join – ACI Membership

30,000 members form the premier community


dedicated to the best use of concrete
– Free access to ACI’s 200+ guides reports
– Concrete International, Structural Journal, Materials Journal
– ACI University, discounts, Q+A opportunities, and more

Learn more and join: concrete.org/membership

WWW.CONCRETE.ORG/ACI318 513
WWW.CONCRETE.ORG/ACI318 514

You might also like