C -COMMON
L – LOW VOLTAGE
H – HIGH VOLTAGE
WALL
EHR1
MIS-ALIGNMENT
8"
[203mm]
4-5/8” 3-5/16”
WRONG
[117.5mm] [84.1mm]
RIGHT
2-3/4” 15/16” 1-1/16”
[70mm] [24mm] [27mm]
STEP 1: STEP 2:
With door magnet securely Attach swivel portion to magnet,
CATCH PLATE ASSEMBLY fastened, aligned and energized, being careful to center the catch
proceed with swivel base plate over the magnet.
assembly.
1-3/4”
[ 44.5mm] NOTE: If door extensions are
required, install before step 2.
2-1/8”
[54mm] STEP 3:
LL
With catch plate assembly WA
WALL
1-3/4”
[44.5mm]
1-1/2”
[38.1mm] STEP 4:
2-3/4” Gently close door and with one
[70mm]
hand adjust base of catch plate
DOOR
WALL
1” 1-1/2” 2”
[38.1mm]
STEP 5:
[25.4mm] [50.8mm]
[76.2mm]
4”
[101.6mm]
in a few spots.
PART NUMBER + A = CHROME // PART NUMBER + C = BRASS
MO
LA
TE
final pressure to insure being careful not to go through door.
NS
template does not fall off
IO
EA T
while assembly takes place.
R
D I N TRUC
S STEP 9:
For either style of mounting (thru door/direct) remove
ONLY alignment template, then place swivel in center.
Align holes, then insert screws and tighten assembly
fully. Lastly, remove mounting template.
STEP 7: OR
DO
Insert alignment template into
center of mounting template.
DOOR
Use tab to rotate to fine
adjustment. While holding
alignment template with one
hand, remove adhesive
backing of tab, then push flat
against door.
DOOR
STEP 8 A:
If not using door assembly OR
1/8”
DO
drill fixture, center punch CATCH PLATE EXTENSION ROD
points indicated on 5/16” ASSEMBLY:
alignment template for either
horizontal or vertical
mounting. For best results,
drill 1/8” pilot holes first, then
follow with 5/16” dia drill.
STEP 8 B:
If using door assembly drill fixture,
alignment template is not required.
Locate drill bushing end into mounting
template, holding firmly flat against door,
then tighten slightly. Make sure fixture is
flat against edge of door, tighten fully and