You are on page 1of 2

WIR-97020B

Typical Wiring Tech Sheet for Revised 10-06


Section 25
(00-02-0257)

Magnetic Switches and


TATTLETALE® Annunciators
Typical Wiring Diagram with 117/117PH Magnetic Switch
20P 20T
Pressure Temperature 117/117PH Hourmeter
Tachometer
+ _ B+

SIG GRD
To Magnetic Sensor,
C S B Alternator “Tach”
Terminal, or
+ _ Signal Generator
PB128S Stop Switch

Voltmeter

+ _
+ _
Battery
Ammeter B+
Distributor Ignition coil
Exciter
ST BAT
Fuel Valve IGN
ACC S
Energized B
Start Switch
to Run Alternator
Starter

Rack Pull Solenoid


(RP2300 Series shown)

Typical Wiring Diagram with MS2100 TATTLETALE®


20P 20T
Pressure Temperature

MS2100 MS2100
Typical Power
Adaptor

6 1 2 3 4 5 6 1 2 3 4 5
G A A S

Spark Plugs
Ignition Generator
“Kill”
Wire

Ignition Coils
WIR-97020B page 1 of 2
Typical Wiring with 518PH TATTLETALE®
518PH CLOSEDLOOP™ Wiring*

20P-F 20T-F
Pressure Temperature
Hourmeter
Tachometer
R
+ _ B+

SIG GRD
G NO NC SW1 SW2 B
To Magnetic Sensor,
** Alternator “Tach”
Terminal, or
+ _ Signal Generator
PB128S Stop Switch Jumper*

Voltmeter

+ _
+ _
Distributor Ignition coil Battery
Ammeter B+

Fuel Valve Exciter


ST BAT
IGN
Energized ACC S
to Run B
Start Switch Alternator

Starter

Rack Pull Solenoid (RP2300 Series shown)


*Jumper is to be removed when connecting a CLOSEDLOOP™ circuit.
**Normally Opened terminal is available on the 518APH & 518E models.

Typical Wiring Diagram with 760A and 761APH


760A/761APH
20P 20T
Pressure Temperature
Hourmeter
TD Tachometer
+ _ B+

NOTE 1 SIG GRD

G NO NC S B
To Magnetic Sensor,
Alternator “Tach”
+ _ Terminal, or
Signal Generator
PB128S Stop Switch
Voltmeter

R
+ _
Distributor Ignition
Coil
+ _
Normally Open Battery
Ammeter B+
Relay with
Flyback Flyback Diode Exciter
Diode ST BAT
Fuel IGN
Valve ACC S
Energized B
to Run Start Switch
Alternator
Flyback
Diode Starter
Rack Pull
Solenoid
(RP2300
Series shown) NOTE 1: With terminal “G” grounded, the time delay operates only on start; after the initial
Flyback time delay, the shut-down circuit is operated immediately when SWICHGAGE® contact operates.
Diode With terminal “G” not grounded, the time delay operates both on start and stop.

FW MURPHY CONTROL SYSTEMS & SERVICES DIVISION COMPUTRONIC CONTROLS, LTD


P.O. Box 470248 P.O. Box 1819 41 - 43 Railway Terrace Nechells
Tulsa, Oklahoma 74147 USA Rosenberg, Texas 77471 USA Birmingham B7 5NG UK
+1.918.317.4100 Fax: +1.918.317.4266 Phone: 281.633.4500 Fax: 281.633.4588 Phone: +44 121 327 8500 Fax: +44 121 327 8501
E-mail: sales@fwmurphy.com E-mail: sales@fwmurphy.com E-mail: info@computroniccontrols.com
INDUSTRIAL PANEL DIVISION Web site: www.fwmurphy.com Web site: www.computroniccontrols.com
Fax: 918.317.4124 FRANK W. MURPHY, LTD FW MURPHY INSTRUMENTS (HANGZHOU) CO. LTD
E-mail: ipdsales@fwmurphy.com Church Rd Laverstock 77 23rd Street
MURPHY POWER IGNITION Salisbury SP1 1QZ UK Hangzhou Economic & Technological Development Area
Web site: www.murphy-pi.com Phone: +44 1722 410055 Fax: +44 1722 410088 Hangzhou, Zhejiang, 310018, China
E-mail: sales@fwmurphy.co.uk Phone: +86 571 8788 6060 Fax: +86 571 8684 8878
www.fwmurphy.com Web site: www.fwmurphy.co.uk
Printed in U.S.A.

WIR-97020B page 2 of 2