Professional Documents
Culture Documents
8’-0”
1A
12’-3”
1A DETAIL 1 1C Dimension key architectural features* including delegated design of steel castings.
any curvature or radii that define the form of the casting.
3’-0”
1B
1A
FINISH FLOOR Structural Engineer of Record: design or delegate design to Call out steel casting on drawings and include casting
the connection engineer the connections between the specification language within contract specification.
casting and adjacent structural elements. When relevant:
4A Call out steel casting on the detail with:
3A Design or delegate connections between casting and
CANOPY ELEVATION adjacent concrete elements.* • CAST CONNEX CUSTOM CAST STEEL NODE, REFER
TO SPECIFICATIONS
• Provide diameter and location of anchor rods within the
CL
GRID GRID cast base plate feature For public projects, callout steel casting on the detail with:
3B Design or delegate connections between casting and • CAST CONNEX CUSTOM CAST STEEL NODE OR
adjacent steel elements.* APPROVED EQUIVALENT, REFER TO SPECIFICATIONS
1B HSS SEE ELEV. • Indicate welded joints where applicable 4B Include Casting Specification within Division 05 of the
PJP, AESS 3B • Include any architecturally exposed structural steel contract specification and coordinate product specific
(AESS) requirements; see Casting Specification for weld requirements with Cast Connex. Specification includes:
1A 16° 16° 1A instructions for AESS craftsmanship.
R=2
CUSTOM STEEL
MAX LRFD LOADS 2B 3C Design or delegate other connections including, Delegate design of steel castings by Cast Connex in
”
NODE, REFER TO
2’-10
AT TOP OF CAST
2’-10
SPECIFICATIONS 1B 1B but not limited to: bolted connections, and connections project specifications.
STEEL NODE to wood products.* • Visual Inspection Criteria for Surface Quality
2B MAX LRFD LOADS MOMENT: 65 K-FT Coordinate surface quality expectations with Cast
AT BOTTOM OF SHEAR: 43 KIPS *Contact a Cast Connex representative to coordinate specific
AXIAL: 285 KIPS
Connex to determine appropriate visual inspection
CAST STEEL NODE detail requirements. criteria
MOMENT: 81 K-FT
SHEAR: 83 KIPS • Coating & Finishing Requirements
0’-6”