You are on page 1of 2

WELDER'S QUALIFICATION TEST CERTIFICATE

(As per ASME SEC IX)

OWNER : KUWAIT OIL COMPANY K.S.C (KOC) Photo

CONTRACTOR: SCHLUMBERGER Date 07 NOV 2016


PROJECT TITLE:HEAVY OIL PRODUCTION FACILITY AT UMM-NIQA STAMP/ID NO : MK- 06

PROJECT NO : 15049 CERTIFICATE NO : WQT-007


WELDER'S / OPERATOR'S NAME : MOHAN REDDY
MANUFACTURER / EMPLOYEER : MARK Technologies Company W.L.L
BASE MATERIAL : API 5L Gr.B MATERIAL THICKNESS / MM :10.97 mm
WELDING PROCEDURE NO.: WPS- MK-08 Test Coupon Production Weld
VARIABLES(QW-350) ACTUAL VALUES RANGE QUALIFIED
WELDING PROCESS GTAW + SMAW GTAW + SMAW
TYPE MANUAL MANUAL
Root : without backing Root : With or without backing
BACKING TYPE
Other passess : With backing Other passess : With backing
PIPE DIAMETER / OD MM 154.4 mm O.D 73.0 mm OD and above
BASE METAL P-NUMBER TO P-NUMBER P1 P 1 to 11, 15, 34, 41 to 49
ELECTRODE, S.F.A No 5.18 and 5.1 5.18 and 5.1
ELECTRODE, CODE DESIGNATION Root ER70S-2 & other passes E 7018 Root ER70S-2 & other passes E 7018
FILLER METAL F-NO F6 and F4 F4 and F6
CONSUMABLE INSERT N/A N/A
FILLER TYPE (solid, metal or flux cored) N/A N/A
DEPOSITED THIKNESS FOR EACH PROCESS 2.5MM GTAW+8.5MM SMAW 5MM GTAW+17MM SMAW
WELDING POSITION 6G All Position
WELDING DIRECTION Root & Other passess- Uphill Root & Other passess- Uphill
TYPE OF FUEL GAS N/A N/A
INERT GAS BACKING N/A N/A
TRANSFER MODE N/A N/A
CURRENT / AC / DC DC DC
POLARITY (GTAW) DC EN DC EN
POLARITY (SMAW) DC EP DC EP
WE CERTIFY THAT THE STATEMENTS IN THIS RECORD ARE CORRECT AND THE TEST SPECIMENS WERE PREPARED, WELDED AND
TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF ASME SEC IX

VISUAL EXAMINATION OF COMPLETED WELD (QW302.4) : ACCEPTABLE


TRANSVERSE FACE AND ROOT BENDS {QW-462.3(a)} LONGITUDINAL BENDS [QW-462.5(b)] SIDE BENDS [QW-462.2]

PIPE BEND SPECIMEN,CORROSION-RESISTANT WELD METAL OVERLAY [QW-462.5(c)]

PLATE BEND SPECIMEN,CORROSION-RESISTANT WELD METAL OVERLAY[QW462.5(d)]

PIPE SPECIMEN, MACRO TEST FOR FUSION [QW-462.5(b)] PLATE SPECIMEN, MACRO TEST FOR FUSION [QW(462.5(e)]
TYPE RESULT TYPE RESULT TYPE RESULT
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
ALTERNATIVE RADIOGRAPHIC EXAMINATION RESULTS[QW-191] : Acceptable, Report No - RT-001 Dated on 05/11/2016

FILLET TEST - FRACTURE TEST [QW-181.2] : NONE LENGTH & PERCENT OF DEFECTS :NONE

MACRO EXAMINATION (QW-184) :NONE FILLET SIZE(in.) :NONE CONCAVITY/CONVEXITY(in.) :NONE

OTHER TESTS :NONE

MECHANICAL TEST CONDUCTED BY :NONE LABORATORY TEST NO :NONE


Approvals MARK TECH SCHLUMBERGER KOC

Signature :

Name :

Date :

MARK-PI-WQT-013 Page 1 of 2
1

MARK-PI-WQT-013 Page 2 of 2