FirExting® SILENT
Reference solution
Fire prevention and
soft flooding in
a data centre
Ta i l o r - m a d e f i r e
protection for
maximum-security
data centres
THE CUSTOMER
T H E R I S K A N A LY S I S
THE SOLUTION
G 310025
Air sampling smoke detector Special sound absorbers are attached to the extinguishing nozzles
therefore serious damage to hard flooding is a further special feature. DARZ’s high requirements in
disks. The indirect damage from Flow regulators were attached to terms of IT security as the design
this is often much worse than the the extinguishing agent cylinders enables the high-security building
fire damage itself – not only in the in order to minimise pressure envelope to remain as intact as
form of temporary server failures, spikes at the start of the extin- possible.
but also due to data damage or guishing process.
even loss. Special protection in the
The soft flooding device also con- vault room
Silent extinguishing system siderably reduces the size of the What distinguishes DARZ from
protects sensitive IT equipment pressure-release vents needed. all other data centre buildings
WAGNER solved this problem This means that a single on-site in Germany is the vault room.
in the server areas of the DARZ F90 conduit system can provide In line with its original purpose,
data centre by developing special pressure relief for all extinguishing the room is hermetically sealed
sound absorbers (FirExting® SILENT zones on the first basement floor from the outside. The pressure
with VdS device approval) which of the DARZ. Only one opening to relief holes required to use a gas
are attached to the extinguishing the outdoors is therefore needed extinguishing system would be
nozzles and reduce the sound for all the pressure relief on the associated with a huge amount
pressure to approx. 98 dB(A). Soft first basement floor. This meets of cost and effort. Instead, active
E X A M P L E S Y S T E M I N T H E D ATA C E N T R E
2 4
3 4
6
1 5
To protect the former vault room, the OxyReduct® fire prevention system feeds in nitrogen via the ventilation system to reduce the oxygen level
and create a fire-retardant atmosphere.
EC
E
WAGNER sets standards for innovative and comprehensive solutions in fire protection:
Y
HAZARD MA
T IO
VER
ASPIRATING with very early fire detection systems, TITANUS® for aspirating smoke detection,
SSION
N
SMOKE
DETECTION FirExting® for fire-extinguishing, OxyReduct® to actively prevent fires from breaking
out and VisuLAN® for hazard management. www.wagner.eu
RE
PP
N
U
A
EM
G
S
EN RE
T FI
© WAGNER Group GmbH. Subject to technical changes without notice. Art. no. 68-30-1295. Last revised 10/2016.
Sales International WAGNER RU GmbH
Austria Businesscentre SMART PARK
WAGNER Group GmbH WAGNER Austria GmbH 117246, Moscow
Schleswigstraße 1–5 Am Hafen 6/1/12 Nauchnij Projezd
D-30853 Langenhagen A-2100 Korneuburg 14 A, Building 1, Office 4.12.
Germany Phone +43 2262 64262 0 Phone +7 495 96767 69
Phone +49 511 97383 0 office@wagner-austria.com info@wagner-russia.com
info@wagner.eu
Benelux Singapore
WAGNER Nederland B.V. WAGNER Asia
Computerweg 10 No. 61 Tai Seng Avenue
NL-3542 DR Utrecht #B1-01 Crescendas Print Media Hub
Phone +31 346 5580 10 Singapore 534167
info@wagner-nl.com Phone +65 6296 7828
info@wagner-asia.com
Great Britain
WAGNER UK Limited Switzerland
Unit H WAGNER SCHWEIZ AG
Suites 3&4 Peek Business Centre Industriestrasse 44
Woodside, Dunmow Road CH-8304 Wallisellen
Bishop’s Stortford Phone +41 44 832540 0
Hertfordshire CM23 5RG info@wagner-schweiz.ch
Phone +44 870 333 6116
info@wagner-uk.com USA
WAGNER Fire Safety, Inc.
Poland 135 Beaver Street #402
WAGNER Poland Sp. z o.o. Waltham, MA 02452
ul. Puławska 38 Phone +1 781 899 9100
PL 05-500 Piaseczno info@wagner-us.com
Phone +48 22 185530 0
info@wagnerpoland.pl