DDSY283 Single-phase Prepayment Watt-hour Meter
1. General
DDSY283 single-phase prepayment watt-hour meter complies with IEC 62053-21,
and is designed to measure AC active energy with the frequency of 50Hz or 60Hz. By
adopting advanced microprocessor to handle data collection, delivery and storage, as
well as using shielded and sealed meter case, the meter features high metering
accuracy, high overload, good electromagnetic immunity, low power consumption,
and long service life.
The user has to purchase credit before using electricity. The maximum allowed power
can be set by the utility within the rated current range. The user card delivers data in a
two-way mode and one user card is used with one meter only. There will be alarm by
LED or by power disconnection when the meter is running out of credit. In addition,
certain anti-tampering can also be achieved with software configuration.
The meter shall be installed indoor or outdoor in a meter box, with working
temperature -25℃~+55℃ and relative humidity 25%RH~95%RH. The meter shall
be protected from the influence of dust, salt mist, dew, and any caustic element.
2.3 Starting: 0.004Ib at the rated voltage, rated frequency and COSφ=1.0
Page 1 of 8
DDSY283 Single-phase Prepayment Watt-hour Meter
C LCD Display
P
Relay U Energy Input/Output
Management IC Card
System
4. Main Functions
4.1 One card works for one specific meter only. In the case of card loss, the user can
go to the utility (credit vending station) to replace one. The old card then becomes
invalid.
4.3 When the meter is working, total kWh consumed and credit available will be
displayed in turn.
Page 2 of 8
DDSY283 Single-phase Prepayment Watt-hour Meter
TOTAL: Total kWh consumed (combined with POWER) or total credit purchased
(combined with BUY)
BUY: Credit purchased
ODD: Credit available
LOW: Low credit alarming
ID: Meter no.
CONST: Constant
COUNT: Number of purchasing
LIMIT: Maximum credit limit or debit limit
CUT: Disconnection
4.4 Over-power alarm: The meter can be set as disconnected when the user consumes
energy over the limited power. In this case of energy overusing, the alarming LED
flashes swiftly and the meter will be disconnected in 60 seconds. After that, the LCD
will show a 180 seconds count-down. The meter will be connected after the user
inserts the user card, or connected automatically after 180 seconds. Power limit can be
set by the software.
4.5 Maximum credit limit: If newly bought credit + credit available > maximum
credit limit (default 9999kWh), the newly bought credit will not be added and the
LCD indicates 9999kWh and LIMIT. The credit purchased remains valid. Credit limit
can be set by the software.
4.6 Precaution: When credit available is less than twice of alarming credit, the
Page 3 of 8
DDSY283 Single-phase Prepayment Watt-hour Meter
alarming LED flashes every second to remind the user to buy credit. In this case,
when the user card is inserted into the meter, the flash interval of the alarming LED
will change to every other second to avoid disconnection. Alarming credit can be set
by the software.
4.7 Disconnection alarm: If the user does not insert user card in the case of
precaution, the meter will be disconnected when the credit available reaches alarming
credit and the LCD indicates “CUT”. The meter can be connected by inserting the
user card. In case that the meter’s own card cannot be found, the user can borrow
another card and insert into the meter to resume power supply.
4.8 Credit purchasing reminding: When credit available is less than alarming credit,
the alarming LED keeps on to remind the user to buy credit.
5. User Instruction
5.1 One card works for one specific meter only. In the case of card loss, the user can
go to the utility (credit vending station) to replace one.
5.2 Before buying credit, the user shall insert the card into the meter to bring the
meter data back to the computer database.
5.3 To load credit to the card, insert the card into the card reader/writer, and at the
same time run the computer software to write encrypted data such as user ID, credit
bought, alarming credit, power limit pattern and limit level into the card.
5.4 To use the card, insert it into the meter. If it is a valid card, the data will be
automatically transferred into the meter. The LCD displays following information in
turn.
Page 4 of 8
DDSY283 Single-phase Prepayment Watt-hour Meter
After that, only total energy consumed and credit available will be displayed in turn.
5.5 When an invalid card is inserted, the LCD will display an error code as below:
5.6 When LCD displays zero credit or negative value, and CUT sign, if the meter is
still working, the user shall buy credit immediately, and report the failure to the utility.
If the user opens the terminal cover when the meter is in normal working status, the
Page 5 of 8
DDSY283 Single-phase Prepayment Watt-hour Meter
meter will be disconnected and the LCD will show CUT once a second as well as an
error code E=08. In this case, the meter can only be connected by the utility with
management card after they come to check and make sure that there is no any failure
or tampering behavior.
The blue button is for checking meter data such as meter ID, total credit purchased,
current credit purchased, alarming credit, number of purchases, date of purchase,
power limit and current power. (Note: The button is invalid when a valid card is
inserted into the meter.) The LCD will exit checking status and resume normal cyclic
display if the button has not been pressed for 15 minutes.
The red button is for resetting the meter in an easier way. By pressing the button
without releasing it, the meter can be reset only by inserting the reset card, which does
not need to meet points 2 and 3 as described below.
8.1 All meters are inspected and tested to be eligible before shipment. If the meter
seals are missing or the meters have been kept in storage too long, the meters shall be
calibrated and sealed by relevant organization before installation.
8.2 The meter shall be fixed vertically without any leaning on a firm and
flame-resistant wall in a dry and ventilated place, with 1.8M as the suggested
installation height. If installed in a dirty place or a place where damage to meter may
occur, the meter shall be protected by a cabinet.
Page 6 of 8
DDSY283 Single-phase Prepayment Watt-hour Meter
8.3 The meter shall be wired as shown in the wiring diagram below. Copper wires are
recommended. Screws in the terminal box shall be screwed down tightly.
8.4 The meter will start to work properly after being wired correctly.
8.5 Due to the function of disconnection upon opening the terminal cover, the
terminal cover must be fixed before opening account and inserting user card.
9. Meter Outline
11.2 The meters shall be kept in original packages with ambient temperature of
-25℃―+70℃, relative humidity less than 95%, and without any caustic element in
the air.
Page 7 of 8
DDSY283 Single-phase Prepayment Watt-hour Meter
11.3 The meters shall be kept on shelves with maximum pileup of 5 cartons. Once
unpacked, maximum 10 single meter boxes can be piled up.