Innovation with Medical Technologies

Model Comparison

12.1" 15"

NeuVision203 NeuVision206
Monitor Size Monitor Size
12.1" 15"

Power Specifications
AC Power Parameter Specifications
AC Input Voltage 100 V - 240 V
Power Input 75 VA
Frequency 50Hz / 60Hz (±1Hz)
Security Level Category I, type BF, CF

Carbon Dioxide Specifications


Parameter Specifications
Work Modes Work, standby
CO 2 Range 0mmHg - 99mmHg (0kPa - 13.2kPa)
Unit mmHg / kPa
0 mmHg - 40 mmHg (0kPa - 5.33kPa): ±2mmHg(±0.3kPa)
CO 2 Accuracy 41mmHg - 76mmHg (5.47kPa - 10.1kPa): ±5mmHg(±0.7kPa)
77mmHg - 99mmHg (10.3kPa - 13.2kPa): ±10mmHg(±1.3kPa)
Waveform Speed 6.25mm/s, 12.5mm/s

Physical Specifications NeuVision 203 / 206


Screen Weight Size (L×W×H) Patient Monitor
12.1" monitor Approx. 4.5kg 310mm ×163mm ×285mm
15" monitor Approx. 5.0kg 370mm ×187mm ×313mm 12.1" / 15" TFT touch screen
Big font mode and adjustable parameter display
Two batteries, able to work for max. 5 hours

NewTech Medical Limited


8400 Normandale Lake Boulevard, Suite 920, Bloomington 55437, Minnesota, USA
Tel: 1-952-837-2688 Fax: 1-952-400-8947 Note: All parameters are based on adults. Please contact us for more specific parameters.
http://www.newtech-medical.com E-mail: info@newtech-medical.com
http://www.newtech-health.com
www.newtech-medical.com
Hardware Specifications
Display
NeuVision 203 / 206 Type TFT touch screen
Dimensions 12.1" (NeuVision 203), 15" (NeuVision 206)
Patient Monitor
Resolution 800 × 600pixels (NeuVision 203), 1024 × 768 pixels (NeuVision 206)

N euVision 203 and 206 are expected to be used in a highly-efficient sensitive nursing environment, including, but not
restricted to operating room monitoring, post-recovery, critical care, operative intensive care, respiratory intensive
care, cardiac care, pharmacodynamic intensive care, pediatric intensive care, neonatal intensive care, etc.
Recorder
Type Thermal array recorder
Printing Paper Size 50mm × 20m
Standard Components
Paper Speed 12.5mm/s, 25mm/s, 50mm/s
12.1" / 15" TFT touch screen
Multiple display interfaces Waveform Max. 3 waveforms
20 types of ventricular arrhythmia and S -T segment analysis Battery
Maximum 480 hours graphic and tabular trends, 700 pieces of NIBP record storage
2 hours ECG waveform review and serial ports enable abundant future upgrades Type Rechargeable lithium battery 14.8 V
ECG: heart rate, 3-/ 7-/ 12-channel ECG waveforms, ST segment analysis and arrhythmia analysis
Battery Capacity 4.4Ah
Two batteries, able to work for max. 5 hours
Optional: IBP, EtCO 2 , 12 lead ECG, Multi-gas, Printer, Central monitoring network system Connector: USB Contact supplier for future upgrade

ECG Specifications VGA Support external connection

5-Lead ECG input ( Standard )


Analog Output Port
Input Modes 3-Lead ECG input (Optional)
12-Lead ECG input (Optional) Nurse Call System 1 piece, can be connected to the port of the nurse call system

Lead Standard AHA, IEC


Heart Rate 15bpm - 300bpm NIBP Specifications Monitoring
1.25mm/mV ( × 1/8), 2.5mm/mV ( × 1/4), 5mm/mV ( × ½), 10mm/mV
Sensitivity
(× 1) 20mm/mV (× 2), 40mm/mV (× 4), Auto. Error: ±5% Work Modes Manual, auto, STAT measuring
Sweep Speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s, Error: ±10% 1min, 2min, 3min, 4min, 5min, 10min, 15min, 30min, 60min, 90min, 2h, 4h, 8h,
Measuring Interval under Auto Mode
Diagnose mode: ≥ 89dB timer interval error: < 10s
CMRR
Surgery & monitor mode: ≥ 100dB Blood Pressure (unit) Adult Pediatric Neonate

Surgery mode: 1Hz -15Hz; monitor mode: 0.5Hz - 25Hz Systolic mmHg 40 - 270 40 - 200 40 -135
Frequency Response
Diagnose mode: 0.05Hz -100Hz
Pressure kPa 5.3 - 35.9 5.3 - 26.6 5.3 - 18.0

Nominal Range of Monitoring Mean mmHg 20 - 230 20 - 165 20 - 110


HR
Pressure kPa 2.7 - 30.6 2.7 - 22.0 2.7 - 14.7
Heart Rate Testing Amplitude ±0.3mV - ± 5mV
Resolution 1bpm Diastolic mmHg 11 - 210 11 -150 11 - 100

Pressure kPa 1.4 - 27.9 1.4 - 20.0 1.4 - 13.3


ST Interval Measuring
Range (-2.0mV) - (+2.0mV) CO2 Monitoring (Optional)
Measuring tolerance: measuring tolerance within
Accuracy (-0.8mV) - (+0.8mV) is ±0.02mV or ±10%, whichever is Measuring Modes Sidestream type, mainstream type
higher.
Measuring Range 0% - 13%
Measuring Lead Lead I and II for selection Protection Level / Type BF
Waveform Sensitivity × 1/4, × 1/2, 1, × 2, × 4, Auto Preheating Time 10s

Sweep Speed 6.25mm/s, 12.5mm/s, 25mm/s Response Time 28ms for sensor
Asphyxia Alarm Off, 10s, 15s, 20s, 25s, 30s, 35s, 40s
Flow Control 50ml/min, 100ml/min or 150ml/min for selection
RR Measuring Range of Breathing Rate 3rpm - 60rpm
Range 0rpm -120rpm Asphyxia Alarm Delay 30s, 35s, 40s, 45s, 50s, 55s, 60s