Liebert CRV+ Row-based Cooling

Intelligent Precision Cooling For Data Center Equipment


Liebert.CRV+ is an ideal row-based cooling
product for data center
The Liebert CRV+ is the Most Efficient Row–Based Cooling
Solution

Liebert.CRV+ is
developed to meet
the new challenges.

Put Precision Cooling


In The Row To Reduce Highest COP!
Energy Consumption More Capacity!
and Optimize
Best Footprint
Operating Conditions Capacity!
For IT Equipment

For maximum application flexibility,


Liebert CRV+ is available in multiple
capacities and configurations:

Direct Expansion Units are air-cooled,


water-cooled or glycol cooled,with two
models of CR025 and CR035.
600mm (24") cabinet 300mm (12") cabinet
Chilled Water Units require connection to
a chilled water source,with two models
of CR025 and CR045.

2
High efficient row-based
cooling for IT devices
Optimize the IT investment

Suitable for row-based cooling or rack-based


cooling with high air return temperature

Liebert.CRV+ optimizes air flow and


maximize the cooling capacity

EC fan High efficient filter


Auto regulation of air flow Ultra clean
Redundancy design Easy to maintain
Energy saving and noise reduction

R410A environment
Liebert controller friendly refrigerant
Display the operating status of each Higher energy efficiency ratio
component intelligently Observe environment protection
Multiple communication modes rules

Temperature sensor Air cooling uses V-shaped


Up to 10 can be connected evaporator
Monitor thermal load continuously
Higher sensible heat ratio
Regulation of multiple control
More cooling capacity
modes

Modular air supply baffles Variable capacity scroll


Flexible air flow management
compressor
Field adjustable right and left air Variable capacity cooling output
supply High energy efficiency
Applicable various kinds of Low cost in whole life
application scenarios

3
High reliable design
High efficient operation
Liebert controller
Graphic display of component operating status and environmental condition
Advanced teamwork mode, up to 32 units can be controlled as a single system
Up to 10 remote rack temperature sensors can be connected
Standard RS485 interface, optional SNMP and TCP/IP interface
Intelligently adjust the cooling capacity and air flow

Variable capacity (EC) scroll compressor


Using R410A environment friendly refrigerant
Scroll compressor technology, 20% to 100% dynamic cooling output
Saving more energy at low load to improve energy efficiency
Reducing number of start/stop times to improve system reliability

EC fan
Auto regulation of fan speed and dynamic air flow output
Low current soft startup
Redundant design, easy to maintain
EC fan can save more than 30% energy

Electronic expansion valve


Stepless regulation of openness 10% - 100%, working with the variable capacity scroll
compressor to save energy
Fast response and precision cooling
Wide regulation range to improve the system energy efficiency ratio
Balancing between the cooling capacity output and thermal load

Optional parts
Dual power input Remote rack temperature sensor
Modular air flow control system Water leakage detection
Condensation pump RDU-SIC card
Low temperature assembly
The above does not include all the optional parts, if one optional part is not listed, please contact
Emerson Network Power Co., Ltd.

4
Liebert.CRV+
Reliable, intelligent and energy
saving

Flexible cooling
Liebert controller can automatically adjust the cooling capacity and air flow according to
thermal load change
Comply with precision cooling of temperature and humidity
The teamwork mode can intelligently control the units to work harmonically in
imbalanced load area.
Adjustable air supply grills, unit can be placed conveniently to meet the left and right air
supply directions in different scenarios

Long service and low cost


High air return temperature to improve energy efficiency
Full front or rear design, saving installation and maintenance time
EC fan, high efficient air flow regulation
Variable capacity technology reduces energy consumption and improve the component
life
Compact design with less footprint

High reliability
Advanced controller automatically balances the operation of parts to prolong the system
life
High quality components that pass strict certification
With expert diagnosis and fault pre-alarm function

Various kinds of configurations


Comply with multi cabinet requirements, suitable for cold/hot aisle sealing
Heat density up to 10kW/rack
Applicable to room with or without anti static floor or the room with insufficient height
Applicable to IDC with high thermal density and hot spot load
Applicable to Smart AilseTM solution

5
The Right Cooling Choice for
a Range of Data Center
Applications

Liebert.CRV+ installs at the ends or within the Liebert CRV is available in Direct Expansion or
row of racks. Chilled Water Models
Ideal for hot/cold aisle configurations. Direct Expansion Models are air cooled, water cooled or glycol
Rows should have no missing racks and minimal cold aisle cooled.
obstructions. Chilled Water Models require connection to a chilled water
Ensure obstruction exists (rack, wall, etc.) directly across from source.
cooling unit.
Optimal performance when used with an Emerson Network
Power SmartAisle cold-aisle containment system.

Typical Configurations
HOT AISLE HOT AISLE HOT AISLE

HOT AISLE HOT AISLE HOT AISLE

By placing Liebert CRV 600mm units All Liebert CRV units communicate with As rack densities increase, inserting
at either end of the rows and inserting each other via unit-to-unit networking to additional cooling units within the row will
300mm wide units throughout, the Liebert ensure even air distribution and optimized meet cooling demand.
iCOM controls ensure that the aisle is system efficiency.
evenly pressurized, simulating cold aisle
containment.
HOT AISLE HOT AISLE

COLD
WALL
AISLE

HOT AISLE HOT AISLE HOT AISLE

For data centers where heat density needs The Liebert CRV adapts to obstructions, Liebert CRV systems operating in hot aisle/
to be increased without installing a raised such as walls, pillars, and open racks doors. cold aisle configuration.
floor or a higher roof, the Liebert CRV and
Emerson Network Power SmartAisle™ cold
aisle containment is the ideal solution.

6
Liebert.CRV+ Innovative
Solutions

Cyclic Cooling System For Supercomputing Center (capacity: 20-100kW)


Liebert.CRV+ can provide corresponding cooling capacity and air supply mode according to the main
equipment requirement.

Liebert.CRV+ Server cabinet Liebert.CRV+

Schematic diagram of cabinet solution CRV+ cabinet-based picture

Cooling capacity: 20-50kW

Liebert.CRV+ Server cabinet Liebert.CRV+

Schematic diagram of high heat density rack CRV+ rack-based picture


solution

Cooling capacity: 50-100kW

7
Liebert.CRV+ Direct Expansion (DX) Unit Technical
Parameters
Model CR025HA CR035HA CR025HW CR035HW
Cooling mode Air-cooled Air-cooled Water/glycol cooled Water/glycol cooled
capacity (kW) 25 39 25 39
Air volume (m3/h) 5000 8500 5000 8500
Electric heater (kW) 3 6 3 6
Humidifier capacity (kg/h) 1.5 1.5 1.5 1.5
Water flow (m3/h) -- -- 3 4.7
Pressure drop (kPa) -- -- 60 90
Connection sizes (mm) -- -- DN32 DN32
FLA (A) 26 46.6 26 46.6
Power supply system 380Vac/50~60Hz 380Vac/50~60Hz
Net weight (kg) 260 335 275 355
Dimensions H×W×D (mm) 2000×300×1100 2000×600×1100 2000×300×1100 2000×600×1100
Note: The displayed performance data is measured under the conditions of 37°C return air temperature (hot aisle) and 45°C condensate
temperature.
If the required data is not listed in the table, please contact Emerson Network Power Co., Ltd.

Liebert.CRV+ Chilled Water (CW) Unit Technical Parameters


Model CR025HC CR045HC
7°C water 10°C water 13°C water 7°C water 10°C water 13°C water
Chilled water conditions supply, 12°C supply, 15°C supply, 18°C supply, 12°C supply, 15°C supply, 18°C
water return water return water return water return water return water return
40°C 36.8 33.1 29.5 64.4 58.0 51.8
37°C 33.1 29.1 25.4 57.8 51.5 44.7
35°C 30.2 26.6 22.8 53.3 46.7 40.2
capacity
32°C 26.3 22.6 18.9 46.6 40.2 33.4
30°C 23.8 20.0 16.2 44.9 35.7 29.1
28°C 21.2 17.4 13.6 40.2 31.3 24.5
Air volume (m3/h) 5000 8500
Electric heater (kW) 3 6
Humidifier capacity (kg/h) 1.5 1.5
Connection sizes (mm) DN28 DN32
FLA (A) 27.5 23.0
Power supply system 220Vac/50~60Hz 380Vac/50~60Hz
Weight (kg) 180 330
Dimensions H×W×D (mm) 2000×300×1100 2000×600×1100
Note: If the required data is not listed in the table, please contact Emerson Network Power Co., Ltd.

8
Liebert.PEX Condenser Air Supply

Consisted of stainless steel connecting part


and erosion-resistant aluminun parts used ship
manufacturing
Stepless fan speed fan control
Fan with low maintenance requirement can adapt to
various kinds of climate conditions

L W

Model Weight No. of fans Dimensions (mm) Dimensions of Dimensions of


(first 5 bits) (kg) (unit) L H W liquid pipe (mm) gas pipe (mm)
LSF32-R3 110 1 1384 990 689 16 22
LSF38-R3 120 1 1384 990 695 16 22
LSF42-R3 130 1 1584 1273 695 16 22
LSF52-R3 140 1 1584 1273 695 22 28
LSF76-R3 220 2 2384 1273 695 22 28
About Emerson Network Power
Emerson Network Power, a business of Emerson (NYSE:EMR), maximizes the reliability, deployment speed, and operation efficiency of
communication network. A trusted industry leader in smart infrastructure technologies, Emerson Network Power provides innovative
data center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and
uncompromised availability regardless of capacity demands. All solutions can be supported by local professional service personnel from
Emerson Network Power around the world. Please visit following website for more product and service information of Emerson Network
Power: www.emersonnetwork.com.cn

About Emerson
Headquartered in St. Louis US, Emerson (NYSE: EMR) is a world leading company, it combines technology and engineering to provide
innovated solutions for global industrial , commercial and consumer market customers through 5 business sections of network power,
process management, industrial automation, environmental optimization technology and business residential solutions. Its revenue in
FY13 is 24.7 billions USD. For more information, please visit: www.Emerson.com.

While every precaution has been taken to ensure accuracy and completeness herein, Emerson Electric Co. assumes no responsibility, and
disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change
without notice

Emerson Network Power Co., Ltd. Hotline before sales: Hotline after sales:
No.1 Kefa Road, Science and Industrial Park,
Nanshan District, Shenzhen
400-887-6526 400-887-6510
Tel: 86-755-86010808
Post Code: 518057

www.emersonnetwork.com.cn

Emerson Network Power™ and the Emerson Network Power logo are service marks and trademarks of Emerson Electric Co.©2014 All rights reserved by Emerson Electric Co.
E-X6216617-0414

You might also like