Liebert.CRV+ is
developed to meet
the new challenges.
2
High efficient row-based
cooling for IT devices
Optimize the IT investment
R410A environment
Liebert controller friendly refrigerant
Display the operating status of each Higher energy efficiency ratio
component intelligently Observe environment protection
Multiple communication modes rules
3
High reliable design
High efficient operation
Liebert controller
Graphic display of component operating status and environmental condition
Advanced teamwork mode, up to 32 units can be controlled as a single system
Up to 10 remote rack temperature sensors can be connected
Standard RS485 interface, optional SNMP and TCP/IP interface
Intelligently adjust the cooling capacity and air flow
EC fan
Auto regulation of fan speed and dynamic air flow output
Low current soft startup
Redundant design, easy to maintain
EC fan can save more than 30% energy
Optional parts
Dual power input Remote rack temperature sensor
Modular air flow control system Water leakage detection
Condensation pump RDU-SIC card
Low temperature assembly
The above does not include all the optional parts, if one optional part is not listed, please contact
Emerson Network Power Co., Ltd.
4
Liebert.CRV+
Reliable, intelligent and energy
saving
Flexible cooling
Liebert controller can automatically adjust the cooling capacity and air flow according to
thermal load change
Comply with precision cooling of temperature and humidity
The teamwork mode can intelligently control the units to work harmonically in
imbalanced load area.
Adjustable air supply grills, unit can be placed conveniently to meet the left and right air
supply directions in different scenarios
High reliability
Advanced controller automatically balances the operation of parts to prolong the system
life
High quality components that pass strict certification
With expert diagnosis and fault pre-alarm function
5
The Right Cooling Choice for
a Range of Data Center
Applications
Liebert.CRV+ installs at the ends or within the Liebert CRV is available in Direct Expansion or
row of racks. Chilled Water Models
Ideal for hot/cold aisle configurations. Direct Expansion Models are air cooled, water cooled or glycol
Rows should have no missing racks and minimal cold aisle cooled.
obstructions. Chilled Water Models require connection to a chilled water
Ensure obstruction exists (rack, wall, etc.) directly across from source.
cooling unit.
Optimal performance when used with an Emerson Network
Power SmartAisle cold-aisle containment system.
Typical Configurations
HOT AISLE HOT AISLE HOT AISLE
By placing Liebert CRV 600mm units All Liebert CRV units communicate with As rack densities increase, inserting
at either end of the rows and inserting each other via unit-to-unit networking to additional cooling units within the row will
300mm wide units throughout, the Liebert ensure even air distribution and optimized meet cooling demand.
iCOM controls ensure that the aisle is system efficiency.
evenly pressurized, simulating cold aisle
containment.
HOT AISLE HOT AISLE
COLD
WALL
AISLE
For data centers where heat density needs The Liebert CRV adapts to obstructions, Liebert CRV systems operating in hot aisle/
to be increased without installing a raised such as walls, pillars, and open racks doors. cold aisle configuration.
floor or a higher roof, the Liebert CRV and
Emerson Network Power SmartAisle™ cold
aisle containment is the ideal solution.
6
Liebert.CRV+ Innovative
Solutions
7
Liebert.CRV+ Direct Expansion (DX) Unit Technical
Parameters
Model CR025HA CR035HA CR025HW CR035HW
Cooling mode Air-cooled Air-cooled Water/glycol cooled Water/glycol cooled
capacity (kW) 25 39 25 39
Air volume (m3/h) 5000 8500 5000 8500
Electric heater (kW) 3 6 3 6
Humidifier capacity (kg/h) 1.5 1.5 1.5 1.5
Water flow (m3/h) -- -- 3 4.7
Pressure drop (kPa) -- -- 60 90
Connection sizes (mm) -- -- DN32 DN32
FLA (A) 26 46.6 26 46.6
Power supply system 380Vac/50~60Hz 380Vac/50~60Hz
Net weight (kg) 260 335 275 355
Dimensions H×W×D (mm) 2000×300×1100 2000×600×1100 2000×300×1100 2000×600×1100
Note: The displayed performance data is measured under the conditions of 37°C return air temperature (hot aisle) and 45°C condensate
temperature.
If the required data is not listed in the table, please contact Emerson Network Power Co., Ltd.
8
Liebert.PEX Condenser Air Supply
L W
About Emerson
Headquartered in St. Louis US, Emerson (NYSE: EMR) is a world leading company, it combines technology and engineering to provide
innovated solutions for global industrial , commercial and consumer market customers through 5 business sections of network power,
process management, industrial automation, environmental optimization technology and business residential solutions. Its revenue in
FY13 is 24.7 billions USD. For more information, please visit: www.Emerson.com.
While every precaution has been taken to ensure accuracy and completeness herein, Emerson Electric Co. assumes no responsibility, and
disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change
without notice
Emerson Network Power Co., Ltd. Hotline before sales: Hotline after sales:
No.1 Kefa Road, Science and Industrial Park,
Nanshan District, Shenzhen
400-887-6526 400-887-6510
Tel: 86-755-86010808
Post Code: 518057
www.emersonnetwork.com.cn
Emerson Network Power™ and the Emerson Network Power logo are service marks and trademarks of Emerson Electric Co.©2014 All rights reserved by Emerson Electric Co.
E-X6216617-0414