Professional Documents
Culture Documents
Brochure APEX 6-50PE PDF
Brochure APEX 6-50PE PDF
com
Al Anoud Tower, 22nd Floor
King Fahad Rd - Olaya, Riyadh 12214
www.tamkeenwater.com
The APEX has been tested and certified to No internal moving parts
EN 12566-3. Small visual footprint
CE marked
CER
TIFIED EN 12566-3 certified
EN 12566-3 Excellent value for money
CE
RTIFIED
V1/02-19
+920035078 adabo@tamkeenwater.com
www.tamkeenwater.com
Treatment Process
Overview
APEX is a simple and robust system for the treatment of wastewater and has proven itself over
many years.
PRIMARY
FINAL
SETTLEMENT
SETTLEMENT
AERATION
Performance
APEX has been designed to meet the UK Royal Commission Standard for effluent. Due to its
unique design, it far exceeded this standard during EN testing.
www.tamkeenwater.com
Treatment Process
Detail
Wastewater from the The Biozone is the The wastewater then The settled sludge
building(s) enters the heart of the treatment flows into the Final is returned to the
Primary Settlement process and is where Settlement Tank (FST) Primary Tank via a
Tank (PST). the liquid effluent is where any remaining non-mechanical air lift
biologically cleaned. fine solids settle at system. This keeps the
Here solids and liquids
the base of the tank bacteria in the Biozone
are separated with the The Biozone is filled
forming sludge. supplied with food even
solids being retained with EDNA media.
when there is little or
for periodic removal by The clear effluent is
Aerobic bacteria no wastewater coming
a tanker. discharged into the
and microorganisms from the building(s)
environment (drainage
Liquid wastewater then clean the wastewater and keeps the system
field or watercourse).
flows into the Biozone. by feeding on the working during low use
pollutants as it flows and holiday periods
through the EDNA
matrix.
www.tamkeenwater.com
Self Regulating
Biozone
One of the major advantages of APEX is that the Biozone
self regulates depending on how much wastewater the system
must process.
20%
requires a 6PE (6 person)
The design of the Biozone enables sewage treatment plant.
APEX to function at only 20%
of its design load (10% on APEX A 6PE sewage treatment
HH models). plant should have at least
three residents using it.
Specifications Details
In Ground Inlet Invert Outlet Invert Power
PE Length (mm) Width (mm)
Depth (mm) (mm)* (mm)† (w)
www.tamkeenwater.com
The Sludge
Management System
All three stage sewage treatment plants
produce sludge as part of the treatment
Settled Sludge Return
process. (SSR)
There are two types of sludge: Settled sludge is recycled from the bottom
of the Final Settlement Tank back to the
Primary Sludge
Primary Settlement Tank using a simple, non-
Solids from the incoming wastewater that
mechanical, air lift.
accumulate in the PST.
650mm Anti-Floatation
Airline
600mm Flange
Inlet duct
1,956mm
1,306mm
1,900mm
PE Length Power
12 1,900mm 0.20Kw
Inlet Outlet
1,900mm
www.tamkeenwater.com
Variants
APEX is available in a range of options:
APEX S APEX AG
(Standard) (Above Ground)
The standard units are constructed from These are reinforced standard units for
polypropylene sheet reinforced with steel. installation above ground.
APEX tanks can be constructed so that they APEX HH tanks are two smaller tanks built into
can be packed inside standard shipping a single shell.
containers.
Underloading is a major problem for many
This is the most popular option for export as it sites as insufficient use will prevent a sewage
greatly reduces the shipping costs. treatment plant from working adequately.
APEX can function at 20% of its design loading
APEX C
but many sites, such as campsites, drop below
20% of their maximum usage for several
(Containerised) months of the year.
The APEX system can be permanently built APEX HH allows 50% of the system to be
inside standard open top shipping containers. turned off. This maximises performance as it
This allows the tanks to be shipped easily and prevents bacteria in the Biozone from being
once on site they can be installed either below starved and allows the system to function at
or above ground as the container provides only 10% of its maximum capability.
added strength to the system.
www.tamkeenwater.com
All APEX tanks come with an audio and visual Commercial sites often present the following
alarm as standard. challenges for wastewater treatment:
Restaurants
Hotels
Campsites
Offices
Schools
Labour Camps
Etc
+920035078 adabo@tamkeenwater.com
Al Anoud Tower, 22nd Floor
King Fahad Rd - Olaya, Riyadh 12214
www.tamkeenwater.com
Installation
The compact design and robust construction Shallow and deep inlet inverts are available for
make installation as simple, quick and low cost most tanks in the range to cater for a range of
as possible. foul drain depths.
APEX is capable of being installed above Please contact our office if you would like the
ground if required. details of your nearest approved installer.
Technical Details
In Ground Inlet Invert Outlet Invert Power
Model PE Length (mm) Width (mm)
Depth (mm) (mm)* (mm)† (w)
The APEX range extends up to 5,000 PE. Please contact our sales office for details.