Professional Documents
Culture Documents
Program Description:
"CRSI-PILECAP" is a spreadsheet program written in MS-Excel for the design and analysis of rigid pile
caps. Pile caps are designed and analyzed in accordance with ACI 318-11 with modifications as necessary
to account for beam shear and punching shear when piles are placed inside the ACI assumed shear failure plane.
Users input the pile type/material, pile shape, pile allowable load, pile size, pile cap material properties,
pile cap depth, bar size, and minimum pile eccentrity (which can also be used to increase pile cap moment demand
if so desired). Design requires the user to simply yet interatively choose a minimum design depth that satisfies
all limit states required by ACI and those recommended by CRSI. The load combination used to change from pile
allowable load to factored load is LF(D+Lfloor) and the assumed strength resistance factor for shear is f = 0.75.
The chosen load factor and strength reduction factor were chosen to provide a factor of safety against shear failure
equivalent to that which was used in the CRSI Design Handbook (2008).
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - ###
d= 33.000 in. ###
d/2= 16.500 in. ###
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 219.09 psi
b0= 84.00 in. Limit State A
0.5
Vc= 607.31 kips based on Vc=4(fc') b0d acting at d/2 from column face
f Vc= 455.49 kips
Vu= -6.37 kips reduced by weight of concrete outside of critical section
Vu/f Vc -0.014
=
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - ###
d= 33.000 in. ###
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi Limit State A
bd= 1386.00 in2
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 33.295 in.
w'= 14 in.
w'/d= 0.420 OK, this limit state should be checked
Vu= 375.97 kips Limit State A
Mu= 5247.57 k-in.
Vud/Mu= 2.385
Mu/(Vud)= 0.419
k= 10
fVc= 574.45 kips
Vu/f Vc= 0.654
Conservatively assuming w'/d=1.0,
Vud/Mu= 2.385
Mu/(Vud)= 0.419
k= 5.244
fVc= 301.22 kips
Vu/f Vc= 1.248
(continued)
Comments:
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 56 in.
d/2= 28 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 219.09 psi
b0= 304.73 in.
Vc= 3738.67 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2804.00 kips
Vu= -100.60 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.036
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 56.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 1948.90 in2
Vc= 213.49 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 160.12 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000
(continued)
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 54.885 in.
w'= 17.120 in.
w'/d= 0.312 OK, this limit state should be checked
Vu= 1760.00 kips
Mu= 30131.20 k-in.
Vud/Mu= 3.206
Mu/(Vud)= 0.312
k= 10.000
fVc= 2242.54 kips
Vu/f Vc= 0.785 Above #DIV/0! Below #DIV/0! Controlling
(continued)
Comments:
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 57.000 in.
d/2= 28.500 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 219.09 psi
b0= 396.00 in.
Vc= 4945.28 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3708.96 kips
Vu= -70.94 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.019
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 57.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 7524.00 in2
Vc= 824.21 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 618.16 kips
Vu= 14.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.024
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 57.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 7524.00 in.
Vc= 824.21 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 618.16 kips
Vu= 14.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.024
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 57.1535 in.
w'= 12.000 in.
w'/d= 0.210 OK, this limit state should be checked
Vu= 3464.73 kips
Mu= 40996.31 k-in.
Vud/Mu= 4.830
Mu/(Vud)= 0.207
k= 10.000
fVc= 3099.12 kips
Vu/f Vc= 1.118
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 55.4605 in.
w'= 12.000 in.
w'/d= 0.216 OK, this limit state should be checked
Vu= 3464.73 kips
Mu= 40996.31 k-in.
Vud/Mu= 4.687
Mu/(Vud)= 0.213
k= 10.000
fVc= 3007.32 kips
Vu/f Vc= 1.152
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size
CRSI Limit State 1 Adequate? NG
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1868.44 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.613 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 33.000 in.
d/2= 16.500 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 219.09 psi
b0= 220.00 in.
Vc= 1590.59 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1192.94 kips
Vu= 1502.51 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 1.260
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 33.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 3066.07 in2
Vc= 335.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 251.90 kips
Vu= -1.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.005
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 33.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 3066.07 in.
Vc= 335.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 251.90 kips
Vu= -1.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.005
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 33.365 in.
w'= 17.456 in.
w'/d= 0.523 OK, this limit state should be checked
Vu= 748.33 kips
Mu= 13057.13 k-in.
Vud/Mu= 1.912
Mu/(Vud)= 0.523
k= 8.764
fVc= 1116.09 kips
Vu/f Vc= 0.670
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 32.095 in.
w'= 17.456 in.
w'/d= 0.544 OK, this limit state should be checked
Vu= 748.33 kips
Mu= 13057.13 k-in.
Vud/Mu= 1.839
Mu/(Vud)= 0.544
k= 8.203
fVc= 1004.86 kips
Vu/f Vc= 0.745
(continued)
Comments:
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 75.000 in.
d/2= 37.500 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 219.09 psi
b0= 504.00 in.
Vc= 8281.57 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 6211.17 kips
Vu= 6928.23 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 1.115
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 75.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 9900.00 in2
Vc= 1084.49 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 813.37 kips
Vu= 7.01 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.009
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 75.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 14400.00 in.
Vc= 1577.44 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1183.08 kips
Vu= 78.20 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.066
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 75.1535 in.
w'= 37.500 in.
w'/d= 0.499 OK, this limit state should be checked
Vu= 3410.14 kips
Mu= 128127.35 k-in.
Vud/Mu= 2.000
Mu/(Vud)= 0.500
k= 9.470
fVc= 3859.20 kips
Vu/f Vc= 0.884
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 73.4605 in.
w'= 7.500 in.
w'/d= 0.102 OK, this limit state should be checked
Vu= 5188.20 kips
Mu= 37741.05 k-in.
Vud/Mu= 10.098
Mu/(Vud)= 0.099
k= 10.000
fVc= 5793.98 kips
Comments:
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? NA
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 581.92 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 13.610 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 74.000 in.
d/2= 37.000 in.
No. of piles outside d/2 from face of the column = 6
4(fc')0.5= 252.98 psi
b0= 276.46 in.
Vc= 5175.52 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3881.64 kips
Vu= 524.88 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.135
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 74.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 11449.16 in2
Vc= 1448.22 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1086.16 kips
Vu= -10.83 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.010
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 74.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 12876.00 in.
Vc= 1628.70 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1221.52 kips
Vu= 7.39 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.006
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 74.1535 in.
w'= 32.000 in.
w'/d= 0.432 OK, this limit state should be checked
Vu= 239.60 kips
Mu= 11119.85 k-in.
Vud/Mu= 1.598
Mu/(Vud)= 0.626
k= 9.237
fVc= 5027.11 kips
Vu/f Vc= 0.048
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 72.4605 in.
w'= 58.359 in.
w'/d= 0.805 OK, this limit state should be checked
Vu= 113.17 kips
Mu= 9915.28 k-in.
Vud/Mu= 0.827
Mu/(Vud)= 1.209
k= 1.175
fVc= 702.58 kips
Vu/f Vc= 0.161
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 833.31 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 14.434 in.
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 41.000 in.
d/2= 20.500 in.
No. of piles outside d/2 from face of the column = 8
4(fc')0.5= 252.98 psi
b0= 224.00 in.
Vc= 2323.39 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1742.54 kips
Vu= 855.52 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.491
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 41.000 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 126.49 psi
bd= 6343.45 in2
Vc= 802.39 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 601.79 kips
Vu= 213.81 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.355
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 41.000 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 126.49 psi
bd= 7134.00 in.
Vc= 902.39 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 676.79 kips
Vu= 348.43 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.515
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 41.5 in.
w'= 31.500 in.
w'/d= 0.759 OK, this limit state should be checked
Vu= 296.87 kips
Mu= 17848.75 k-in.
Vud/Mu= 0.690
Mu/(Vud)= 1.449
k= -0.316
fVc= -96.25 kips
Vu/f Vc= -3.084
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 40.436 in.
w'= 57.852 in.
w'/d= 1.431 Limit state not applicable
Vu= 297.90 kips
Mu= 19207.68 k-in.
Vud/Mu= 0.627
Mu/(Vud)= 1.595
k= -0.667
fVc= -222.68 kips
Comments:
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - distance fro
d= 80.000 in. distance fro
d/2= 40.000 in. distance fro
No. of piles outside d/2 from face of the column = 8
4(fc')0.5= 252.98 psi
b0= 376.00 in. Limit State A
0.5
Vc= 7609.70 kips based on Vc=4(fc') b0d acting at d/2 from column face
fVc= 5707.28 kips
Vu= 756.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.132
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - distance fro
d= 80.000 in. distance fro
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi Limit State A
bd= 13920.00 in2
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 - distance fro
d= 80.000 in. distance fro
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi Limit State A
bd= 13920.00 in.
Vc= 1760.76 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1320.57 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 80.1535 in.
w'= 68.000 in.
w'/d= 0.848 OK, this limit state should be checked
Vu= 210.00 kips
Mu= 19152.00 k-in. Limit State A
Vud/Mu= 0.879
Mu/(Vud)= 1.138
k= 1.536
fVc= 1016.05 kips
Vu/f Vc= 0.207
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 78.4605 in.
w'= 68.000 in.
w'/d= 0.867 OK, this limit state should be checked
Vu= 210.00 kips
Mu= 19152.00 k-in. Limit State A
Vud/Mu= 0.860
Mu/(Vud)= 1.162
k= 1.361
fVc= 881.58 kips
Vu/f Vc= 0.238
(continued)
Vu=
d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=
Vu=
Vu/f Vc=
d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 851.82 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 14.593 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 71.000 in.
d/2= 35.500 in.
No. of piles outside d/2 from face of the column = 8
4(fc')0.5= 252.98 psi
b0= 344.00 in.
Vc= 6178.84 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 4634.13 kips
Vu= 679.02 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.147
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 71.000 in.
No. of piles outside d from face of the column = 1
2(fc')0.5= 126.49 psi
bd= 10985.01 in2
Vc= 1389.51 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1042.13 kips
Vu= 50.54 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.049
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 71.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 17466.00 in.
Vc= 2209.29 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1656.97 kips
Vu= 3.16 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.002
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 71.1535 in.
w'= 31.500 in.
w'/d= 0.443 OK, this limit state should be checked
Vu= 310.96 kips
Mu= 22950.10 k-in.
Vud/Mu= 0.964
Mu/(Vud)= 1.037
k= 4.090
fVc= 2135.61 kips
Vu/f Vc= 0.146
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 69.4605 in.
w'= 57.852 in.
w'/d= 0.833 OK, this limit state should be checked
Vu= 190.66 kips
Mu= 15462.04 k-in.
Vud/Mu= 0.857
Mu/(Vud)= 1.168
k= 1.386
fVc= 1123.16 kips
Comments:
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? NG CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? NG
Results:
Column Size Determination
Net Column Capacity Pu= 1074.97 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 16.393 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 53.000 in.
d/2= 26.500 in.
No. of piles outside d/2 from face of the column = 10
4(fc')0.5= 252.98 psi
b0= 280.00 in.
Vc= 3754.26 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2815.69 kips
Vu= 989.84 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.352
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 53.000 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 126.49 psi
bd= 8200.08 in2
Vc= 1037.24 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 777.93 kips
Vu= 300.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.387
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 53.000 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 126.49 psi
bd= 13038.00 in.
Vc= 1649.19 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1236.89 kips
Vu= 477.86 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.386
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 53.295 in.
w'= 30.500 in.
w'/d= 0.572 OK, this limit state should be checked
Vu= 484.99 kips
Mu= 33685.76 k-in.
Vud/Mu= 0.767
Mu/(Vud)= 1.303
k= 0.836
fVc= 326.79 kips
Vu/f Vc= 1.484
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 51.885 in.
w'= 56.859 in.
w'/d= 1.096 Limit state not applicable
Vu= 363.78 kips
Mu= 24008.77 k-in.
Vud/Mu= 0.786
Mu/(Vud)= 1.272
k= 0.578
fVc= 349.79 kips
Comments:
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1250.64 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 17.682 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38.000 in.
d/2= 19.000 in.
No. of piles outside d/2 from face of the column = 12
4(fc')0.5= 252.98 psi
b0= 224.00 in.
Vc= 2153.38 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1615.04 kips
Vu= 1271.55 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.787
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38.000 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 126.49 psi
bd= 6612.00 in2
Vc= 836.36 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 627.27 kips
Vu= 295.84 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.472
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38.000 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 126.49 psi
bd= 9348.00 in.
Vc= 1182.44 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 886.83 kips
Vu= 446.40 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.503
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.365 in.
w'= 30.000 in.
w'/d= 0.782 OK, this limit state should be checked
Vu= 635.76 kips
Mu= 43150.32 k-in.
Vud/Mu= 0.565
Mu/(Vud)= 1.769
k= -2.309
fVc= -731.10 kips
Vu/f Vc= -0.870
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 37.355 in.
w'= 66.000 in.
w'/d= 1.767 Limit state not applicable
Vu= 384.08 kips
Mu= 28803.12 k-in.
Vud/Mu= 0.498
Mu/(Vud)= 2.008
k= -1.676
fVc= -730.64 kips
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1272.36 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 17.835 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48.000 in.
d/2= 24.000 in.
No. of piles outside d/2 from face of the column = 12
4(fc')0.5= 252.98 psi
b0= 264.00 in.
Vc= 3205.79 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2404.34 kips
Vu= 1179.45 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.491
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 8352.00 in2
Vc= 1056.45 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 792.34 kips
Vu= 524.08 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.661
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48.000 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 126.49 psi
bd= 13411.58 in.
Vc= 1696.45 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1272.33 kips
Vu= 316.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.249
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.365 in.
w'= 56.352 in.
w'/d= 1.165 Limit state not applicable
Vu= 456.80 kips
Mu= 48035.74 k-in.
Vud/Mu= 0.460
Mu/(Vud)= 2.174
k= -3.233
fVc= -1290.50 kips
Vu/f Vc= -0.354
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.23 in.
w'= 30.000 in.
w'/d= 0.635 OK, this limit state should be checked
Vu= 464.44 kips
Mu= 26177.11 k-in.
Vud/Mu= 0.838
Mu/(Vud)= 1.193
k= 1.613
fVc= 1009.89 kips
Actual Stres
Actual Stres
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - distance fro
d= 60.000 in. distance fro
d/2= 30.000 in. distance fro
No. of piles outside d/2 from face of the column = 14 distance fro
4(fc')0.5= 252.98 psi distance fro
b0= 312.00 in. distance fro
0.5
Vc= 4735.83 kips based on Vc=4(fc') b0d acting at d/2 from column face
fVc= 3551.87 kips Limit State A
Vu= 1308.95 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.369
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - distance fro
d= 60.000 in. distance fro
No. of piles outside d from face of the column = 4 distance fro
2(fc')0.5= 126.49 psi distance fro
bd= 13602.24 in2 Limit State A
Vc= 1720.56 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1290.42 kips
Vu= 392.98 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.305
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 - distance fro
d= 60.000 in. distance fro
No. of piles outside d from face of the column = 3 distance fro
2(fc')0.5= 126.49 psi Limit State A
bd= 14760.00 in.
Vc= 1867.01 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1400.26 kips
Vu= 277.92 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.198
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 60.365 in.
w'= 30.000 in.
w'/d= 0.497 OK, this limit state should be checked
Vu= 516.74 kips
Mu= 36365.97 k-in. Limit State A
Vud/Mu= 0.858
Mu/(Vud)= 1.166
k= 2.339
fVc= 1518.35 kips
Vu/f Vc= 0.340
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 59.166 in.
w'= 30.000 in.
w'/d= 0.507 OK, this limit state should be checked
Vu= 646.42 kips
Mu= 38105.46 k-in. Limit State A
Vud/Mu= 1.004
Mu/(Vud)= 0.996
k= 3.981
fVc= 2748.79 kips
Vu/f Vc= 0.235
(continued)
Vu=
d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=
Vu=
Vu/f Vc=
d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1503.16 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 19.385 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38.000 in.
d/2= 19.000 in.
No. of piles outside d/2 from face of the column = 14
4(fc')0.5= 252.98 psi
b0= 232.00 in.
Vc= 2230.29 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1672.72 kips
Vu= 1397.59 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.836
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38.000 in.
No. of piles outside d from face of the column = 6
2(fc')0.5= 126.49 psi
bd= 9348.00 in2
Vc= 1182.44 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 886.83 kips
Vu= 638.30 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.720
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 10617.50 in.
Vc= 1343.02 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1007.26 kips
Vu= 520.99 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.517
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.295 in.
w'= 55.352 in.
w'/d= 1.445 Limit state not applicable
Vu= 575.98 kips
Mu= 47062.89 k-in.
Vud/Mu= 0.469
Mu/(Vud)= 2.134
k= -2.471
fVc= -1103.97 kips
Vu/f Vc= -0.522
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 36.885 in.
w'= 29.000 in.
w'/d= 0.786 OK, this limit state should be checked
Vu= 706.21 kips
Mu= 48600.96 k-in.
Vud/Mu= 0.536
Mu/(Vud)= 1.866
k= -2.893
fVc= -1414.47 kips
Comments:
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - distance fro
d= 61.000 in. distance fro
d/2= 30.500 in. distance fro
No. of piles outside d/2 from face of the column = 12 distance fro
4(fc')0.5= 252.98 psi distance fro
b0= 324.00 in. Limit State A
0.5
Vc= 4999.94 kips based on Vc=4(fc') b0d acting at d/2 from column face
fVc= 3749.96 kips
Vu= 1003.94 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.268
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - distance fro
d= 61.000 in. distance fro
No. of piles outside d from face of the column = 4 distance fro
2(fc')0.5= 126.49 psi Limit State A
bd= 15006.00 in2
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 - distance fro
d= 61.000 in. distance fro
No. of piles outside d from face of the column = 4 distance fro
2(fc')0.5= 126.49 psi Limit State A
bd= 15006.00 in.
Vc= 1898.13 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1423.59 kips
Vu= 385.86 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.271
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 61.436 in.
w'= 29.000 in.
w'/d= 0.472 OK, this limit state should be checked
Vu= 749.88 kips
Mu= 51072.27 k-in. Limit State A
Vud/Mu= 0.902
Mu/(Vud)= 1.109
k= 3.072
fVc= 2202.02 kips
Vu/f Vc= 0.341
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 60.308 in.
w'= 29.000 in.
w'/d= 0.481 OK, this limit state should be checked
Vu= 749.88 kips
Mu= 51072.27 k-in. Limit State A
Vud/Mu= 0.885
Mu/(Vud)= 1.129
k= 2.798
fVc= 1969.28 kips
Vu/f Vc= 0.381
(continued)
Vu=
d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=
Vu=
Vu/f Vc=
d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1733.11 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 20.815 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 41.000 in.
d/2= 20.500 in.
No. of piles outside d/2 from face of the column = 16
4(fc')0.5= 252.98 psi
b0= 248.00 in.
Vc= 2572.32 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1929.24 kips
Vu= 1632.34 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.846
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 41.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 10086.00 in2
Vc= 1275.79 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 956.84 kips
Vu= 764.29 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.799
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 41.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 11455.73 in.
Vc= 1449.05 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1086.79 kips
Vu= 520.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.479
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 41.295 in.
w'= 54.852 in.
w'/d= 1.328 Limit state not applicable
Vu= 692.85 kips
Mu= 61080.69 k-in.
Vud/Mu= 0.468
Mu/(Vud)= 2.135
k= -2.693
fVc= -1297.47 kips
Vu/f Vc= -0.534
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 39.955 in.
w'= 28.500 in.
w'/d= 0.713 OK, this limit state should be checked
Vu= 801.35 kips
Mu= 53523.75 k-in.
Vud/Mu= 0.598
Mu/(Vud)= 1.672
k= -1.866
fVc= -988.22 kips
Comments: ###
###
###
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1750.31 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 20.918 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48.000 in.
d/2= 24.000 in.
No. of piles outside d/2 from face of the column = 18
4(fc')0.5= 252.98 psi
b0= 276.00 in.
Vc= 3351.51 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2513.63 kips
Vu= 1788.66 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.712
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 11808.00 in2
Vc= 1493.61 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1120.21 kips
Vu= 735.08 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.656
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 13411.58 in.
Vc= 1696.45 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1272.33 kips
Vu= 494.82 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.389
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.365 in.
w'= 54.852 in.
w'/d= 1.134 Limit state not applicable
Vu= 639.96 kips
Mu= 64530.97 k-in.
Vud/Mu= 0.480
Mu/(Vud)= 2.085
k= -2.941
fVc= -1659.74 kips
Vu/f Vc= -0.386
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.166 in.
w'= 28.500 in.
w'/d= 0.604 OK, this limit state should be checked
Vu= 770.79 kips
Mu= 51804.74 k-in.
Vud/Mu= 0.702
Mu/(Vud)= 1.425
k= -0.204
fVc= -127.25 kips
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1880.89 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.685 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 44.000 in.
d/2= 22.000 in.
No. of piles outside d/2 from face of the column = 18
4(fc')0.5= 252.98 psi
b0= 264.00 in.
Vc= 2938.64 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2203.98 kips
Vu= 1785.56 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.810
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 44.000 in.
No. of piles outside d from face of the column = 8
2(fc')0.5= 126.49 psi
bd= 10824.00 in2
Vc= 1369.14 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1026.85 kips
Vu= 849.92 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.828
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 44.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 13142.98 in.
Vc= 1662.47 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1246.85 kips
Vu= 487.66 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.391
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 44.295 in.
w'= 54.352 in.
w'/d= 1.227 Limit state not applicable
Vu= 768.74 kips
Mu= 74862.62 k-in.
Vud/Mu= 0.455
Mu/(Vud)= 2.199
k= -3.165
fVc= -1635.97 kips
Vu/f Vc= -0.470
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 42.955 in.
w'= 28.000 in.
w'/d= 0.652 OK, this limit state should be checked
Vu= 901.09 kips
Mu= 59676.96 k-in.
Vud/Mu= 0.649
Mu/(Vud)= 1.542
k= -1.069
fVc= -650.31 kips
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1810.32 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.274 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 59.000 in.
d/2= 29.500 in.
No. of piles outside d/2 from face of the column = 18
4(fc')0.5= 252.98 psi
b0= 324.00 in.
Vc= 4836.01 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3627.01 kips
Vu= 1617.19 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.446
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 59.000 in.
No. of piles outside d from face of the column = 8
2(fc')0.5= 126.49 psi
bd= 14514.00 in2
Vc= 1835.89 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1376.92 kips
Vu= 814.18 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.591
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 59.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 18762.00 in.
Vc= 2373.23 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1779.92 kips
Vu= 478.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.269
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 59.295 in.
w'= 64.000 in.
w'/d= 1.079 Limit state not applicable
Vu= 675.09 kips
Mu= 76580.66 k-in.
Vud/Mu= 0.523
Mu/(Vud)= 1.913
k= -2.320
fVc= -1605.35 kips
Vu/f Vc= -0.421
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 58.026 in.
w'= 28.000 in.
w'/d= 0.483 OK, this limit state should be checked
Vu= 938.68 kips
Mu= 62806.08 k-in.
Vud/Mu= 0.867
Mu/(Vud)= 1.153
k= 2.541
fVc= 2224.49 kips
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1999.84 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 22.360 in.
Rounded Dimension c= 23 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 50.000 in.
d/2= 25.000 in.
No. of piles outside d/2 from face of the column = 20
4(fc')0.5= 252.98 psi
b0= 292.00 in.
V c= 3693.54 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2770.16 kips
Vu= 1916.25 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.692
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 50.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 14305.96 in2
V c= 1809.58 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1357.18 kips
Vu= 705.01 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.519
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 50.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 14935.20 in.
V c= 1889.17 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1416.88 kips
Vu= 705.01 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.498
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 50.295 in.
w'= 27.500 in.
w'/d= 0.547 OK, this limit state should be checked
Vu= 836.55 kips
M u= 75316.49 k-in.
Vud/Mu= 0.559
Mu/(Vud)= 1.790
k= -3.489
fVc= -2485.98 kips
Vu/f Vc= -0.337 **CONTROLLING** Vu/f Vc= -0.337
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 48.885 in.
w'= 27.500 in.
w'/d= 0.563 OK, this limit state should be checked
Vu= 836.55 kips
M u= 71792.22 k-in.
Vud/Mu= 0.570
Mu/(Vud)= 1.756
k= -3.092
fVc= -2141.76 kips
Vu/f Vc= -0.391 **CONTROLLING** Vu/f Vc= -0.391
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2104.36 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 22.937 in.
Rounded Dimension c= 23 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 52.000 in.
d/2= 26.000 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 252.98 psi
b 0= 300.00 in.
Vc= 3946.52 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
f Vc= 2959.89 kips
Vu= 2152.80 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.727
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 52.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 14529.22 in2
Vc= 1837.82 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1378.36 kips
Vu= 692.96 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.503
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 52.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 16536.00 in.
Vc= 2091.66 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1568.74 kips
Vu= 970.06 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.618
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 52.295 in.
w'= 27.500 in.
w'/d= 0.526 OK, this limit state should be checked
Vu= 951.85 kips
Mu= 77412.80 k-in.
Vud/Mu= 0.643
Mu/(Vud)= 1.555
k= -1.449
fVc= -1004.48 kips
Vu/f Vc= -0.948 **CONTROLLING** Vu/f Vc= -0.948
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 50.885 in.
w'= 53.852 in.
w'/d= 1.058 Limit state not applicable
Vu= 827.67 kips
Mu= 74539.35 k-in.
Vud/Mu= 0.565
Mu/(Vud)= 1.770
k= -1.709
fVc= -1312.05 kips
Vu/f Vc= -0.631 **CONTROLLING** Vu/f Vc= -0.631
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2228.84 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 23.605 in.
Rounded Dimension c= 24 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48.000 in.
d/2= 24.000 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 252.98 psi
b0= 288.00 in.
V c= 3497.23 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2622.92 kips
Vu= 2142.60 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.817
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48.000 in.
No. of piles outside d from face of the column = 8
2(fc')0.5= 126.49 psi
bd= 14337.79 in2
V c= 1813.60 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1360.20 kips
Vu= 810.79 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.596
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 15264.00 in.
V c= 1930.76 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1448.07 kips
Vu= 948.12 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.655
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.295 in.
w'= 27.000 in.
w'/d= 0.559 OK, this limit state should be checked
Vu= 951.30 kips
M u= 85913.72 k-in.
Vud/Mu= 0.535
Mu/(Vud)= 1.870
k= -4.106
fVc= -2809.51 kips
Vu/f Vc= -0.339 **CONTROLLING** Vu/f Vc= -0.339
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 46.885 in.
w'= 63.000 in.
w'/d= 1.344 Limit state not applicable
Vu= 825.16 kips
M u= 83460.67 k-in.
Vud/Mu= 0.464
Mu/(Vud)= 2.157
k= -2.742
fVc= -1939.42 kips
Vu/f Vc= -0.425 **CONTROLLING** Vu/f Vc= -0.425
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2201.28 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 23.459 in.
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 56.000 in.
d/2= 28.000 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 252.98 psi
b0= 320.00 in.
Vc= 4533.44 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3400.08 kips
Vu= 2003.94 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.589
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 56.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 16727.42 in2
Vc= 2115.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1586.90 kips
Vu= 902.83 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.569
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 56.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 17808.00 in.
Vc= 2252.55 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1689.42 kips
Vu= 402.86 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.238
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 56.295 in.
w'= 27.000 in.
w'/d= 0.480 OK, this limit state should be checked
Vu= 877.50 kips
Mu= 87919.98 k-in.
Vud/Mu= 0.562
Mu/(Vud)= 1.780
k= -3.873
fVc= -3089.01 kips
Vu/f Vc= -0.284
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 54.955 in.
w'= 53.352 in.
w'/d= 0.971 OK, this limit state should be checked
Vu= 879.62 kips
Mu= 86873.99 k-in.
Vud/Mu= 0.556
Mu/(Vud)= 1.797
k= -2.000
fVc= -1657.99 kips
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? NG
Results:
Column Size Determination
Net Column Capacity Pu= 2331.24 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 24.141 in.
Rounded Dimension c= 25 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 58.000 in.
d/2= 29.000 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 252.98 psi
b0= 332.00 in.
V c= 4871.43 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3653.57 kips
Vu= 1884.30 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.516
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 58.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 18444.00 in2
V c= 2333.00 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1749.75 kips
Vu= 865.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.495
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 58.000 in.
No. of piles outside d from face of the column = 8
2(fc')0.5= 126.49 psi
bd= 20381.66 in.
V c= 2578.10 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1933.57 kips
Vu= 759.60 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.393
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 58.295 in.
w'= 26.500 in.
w'/d= 0.455 OK, this limit state should be checked
Vu= 1203.16 kips
M u= 112286.81 k-in.
Vud/Mu= 0.625
Mu/(Vud)= 1.601
k= -2.169
fVc= -1906.90 kips
Vu/f Vc= -0.631 **CONTROLLING** Vu/f Vc= -0.631
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 56.885 in.
w'= 26.500 in.
w'/d= 0.466 OK, this limit state should be checked
Vu= 1079.11 kips
M u= 83064.89 k-in.
Vud/Mu= 0.739
Mu/(Vud)= 1.353
k= 0.496
fVc= 470.28 kips
Vu/f Vc= 2.295 **CONTROLLING** Vu/f Vc= 2.295
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2528.60 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 25.143 in.
Rounded Dimension c= 26 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 58.000 in.
d/2= 29.000 in.
No. of piles outside d/2 from face of the column = 26
4(fc')0.5= 252.98 psi
b 0= 336.00 in.
Vc= 4930.12 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3697.59 kips
Vu= 2339.24 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.633
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 58.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 18444.00 in2
Vc= 2333.00 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1749.75 kips
Vu= 837.54 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.479
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 58.000 in.
No. of piles outside d from face of the column = 12
2(fc')0.5= 126.49 psi
bd= 20381.66 in.
Vc= 2578.10 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1933.57 kips
Vu= 1243.94 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.643
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 58.295 in.
w'= 26.000 in.
w'/d= 0.446 OK, this limit state should be checked
Vu= 1303.35 kips
Mu= 118573.78 k-in.
Vud/Mu= 0.641
Mu/(Vud)= 1.561
k= -1.768
fVc= -1554.93 kips
Vu/f Vc= -0.838
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 56.955 in.
w'= 26.000 in.
w'/d= 0.457 OK, this limit state should be checked
Vu= 1051.45 kips
Mu= 96723.66 k-in.
Vud/Mu= 0.619
Mu/(Vud)= 1.615
k= -2.312
fVc= -2194.61 kips
Vu/f Vc= -0.479
(continued)
Comments:
lavailable= 120.000 in. OK; sufficient length available to develop bar ys=
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - distance from
d= 49.000 in. distance from
d/2= 24.500 in. distance from
No. of piles outside d/2 from face of the column = 24 distance from
4(fc')0.5= 252.98 psi distance from
b 0= 652.00 in. distance from
0.5
Vc= 8082.28 kips based on Vc=4(fc') b0d acting at d/2 from column face
fVc= 6061.71 kips Limit State Al
Vu= 41183.32 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 6.794
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - distance from
d= 49.000 in. distance from
No. of piles outside d from face of the column = 10 distance from
2(fc')0.5= 126.49 psi distance from
bd= 17640.00 in2
Vc= 2231.30 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1673.48 kips Limit State Al
Vu= 17275.50 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 10.323
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 - distance from
d= 49.000 in. distance from
No. of piles outside d from face of the column = 6 distance from
2(fc')0.5= 126.49 psi
bd= 21168.00 in.
Vc= 2677.56 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 2008.17 kips Limit State Al
Vu= 10298.04 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 5.128
(continued)
Check two way shear at column face - CRSI LIMIT STATE 4 - Make sure lar
d= 49.000 in. NG, but answ
d/2= 24.500 in. 32(fc')0.5=
No. of piles outside face of the column = 30 ###
wactual -18.000 in. < d/2 This procedure applies ###
Vu 51632.10 kips 4(fc')0.5=
4(fc')0.5= 252.98 psi 32(fc')0.5=
32(fc')0.5= 2023.86 psi b0=
b 0= 652.000 in. Limit State Al
b s= 456.000 in. k=
k= -7.785 based on k=2(d/w)(1+d/c) acting at column face ###
Vc= -11000.88 kips based on Vc=k(fc')0.5bsd acting at column face ###
fVc= -8250.66 kips ###
Vu/f Vc= -6.258 ****COMBINED**** Vu/f Vc= 3.129
###
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 - Limit State Al
d= 49.295 in. w'=
w'= -18.000 in. w'/d=
w'/d= 0.000 OK, this limit state should be checked Vu=
Vu= 25930.95 kips M u=
Mu= 1388310.53 k-in. Vud/Mu=
Vud/Mu= 0.921 Mu/(Vud)=
Mu/(Vud)= 1.086 k=
k= #DIV/0!
fVc= #DIV/0! kips
Vu/f Vc= #DIV/0! **CONTROLLING** Vu/f Vc= -10.571
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 - Limit State Al
d= 47.885 in. w'=
w'= 18.000 in. w'/d=
w'/d= 0.376 OK, this limit state should be checked Vu=
Vu= 20684.58 kips M u=
Mu= 1113701.67 k-in. Vud/Mu=
Vud/Mu= 0.889 Mu/(Vud)=
Mu/(Vud)= 1.124 k=
k= 3.646
fVc= 3577.12 kips
Vu/f Vc= 5.782 **CONTROLLING** Vu/f Vc= 5.782
(continued)
Vu=
d=
d/2=
Length dimen
Area in shear
4(fc')0.5=
Vc=
Vu=
Vu/f Vc=
d=
dcritical=
diagonal =
Area in shear
2(fc')0.5=
Vc=