"CRSI-PILECAP" --- PILECAP DESIGN AND ANALYSIS SPREADSHEET

Program Description:

"CRSI-PILECAP" is a spreadsheet program written in MS-Excel for the design and analysis of rigid pile
caps. Pile caps are designed and analyzed in accordance with ACI 318-11 with modifications as necessary
to account for beam shear and punching shear when piles are placed inside the ACI assumed shear failure plane.
Users input the pile type/material, pile shape, pile allowable load, pile size, pile cap material properties,
pile cap depth, bar size, and minimum pile eccentrity (which can also be used to increase pile cap moment demand
if so desired). Design requires the user to simply yet interatively choose a minimum design depth that satisfies
all limit states required by ACI and those recommended by CRSI. The load combination used to change from pile
allowable load to factored load is LF(D+Lfloor) and the assumed strength resistance factor for shear is f = 0.75.
The chosen load factor and strength reduction factor were chosen to provide a factor of safety against shear failure
equivalent to that which was used in the CRSI Design Handbook (2008).

This program is a workbook consisting of twenty-seven (27) worksheets, described as follows:

Worksheet Name Description


Doc This documentation sheet
2 Pile Cap Pile Cap Design for 2 Piles
3 Pile Cap Pile Cap Design for 3 Piles (Round Column)
4 Pile Cap Pile Cap Design for 4 Piles
5 Pile Cap Pile Cap Design for 5 Piles
6 Pile Cap Pile Cap Design for 6 Piles
7 Pile Cap Pile Cap Design for 7 Piles (Round Column)
8 Pile Cap Pile Cap Design for 8 Piles
9 Pile Cap Pile Cap Design for 9 Piles
10 Pile Cap Pile Cap Design for 10 Piles
11 Pile Cap Pile Cap Design for 11 Piles
12 Pile Cap Pile Cap Design for 12 Piles
13 Pile Cap Pile Cap Design for 13 Piles
14 Pile Cap Pile Cap Design for 14 Piles
15 Pile Cap Pile Cap Design for 15 Piles
16 Pile Cap Pile Cap Design for 16 Piles
17 Pile Cap Pile Cap Design for 17 Piles
18 Pile Cap Pile Cap Design for 18 Piles
19 Pile Cap Pile Cap Design for 19 Piles
20 Pile Cap Pile Cap Design for 20 Piles
21 Pile Cap Pile Cap Design for 21 Piles
22 Pile Cap Pile Cap Design for 22 Piles
23 Pile Cap Pile Cap Design for 23 Piles
24 Pile Cap Pile Cap Design for 24 Piles
26 Pile Cap Pile Cap Design for 26 Piles
28 Pile Cap Pile Cap Design for 28 Piles
30 Pile Cap Pile Cap Design for 30 Piles

Program Assumptions and Limitations:


General Note: This spreadsheet is part of the CRSI Pile Cap Design Guide (2015). This program should only be used
in conjunction with the design requirements and recommendations as presented in the CRSI Pile Cap Design Guide.
For a complete list of terms used in this spreadsheet, please see the CRSI Pile Cap Design Guide (2015).
1. The CRSI-PILECAP worksheets assume rigid cap load distribution to each pile (i.e., equal load distribution)
for a pile group.
2. The tabulated designs are based upon the use of a square reinforced concrete column of at least the minimum size indicated or
a structural steel column on a steel base plate such that the section half-way between the column face
and the edge of the base plate is equivalent to the size of the column.
3. The tabulated designs are adequate (and conservative) for rectangular columns or steel base
plates if the short side or section is equal to the minimum tabulated column size.
4. A minimum embedment of 6 inches has been established as good practice with structural
steel shapes to avoid use of cover plates for bearing. If precast, concrete, or timber piles are to be used in the tabulated
designs, a minimum embedment of 4 inches is usually sufficient.
5. A minimum pile spacing equal to the maximum of (a) 3 ft o.c., (b) 3 times the pile dimension,
and (c) 2 ft clear between piles is used in the worksheets. The 3 times the pile dimension requirement is based on current
geotechnical recommendations that result in expected maximum pile capacities.
6. Note that some tabulated designs show dimensions on the line below. These dimensions are for use with “clipped corners”
to save concrete. In other words, the “clipped corner” dimensions are the truncated dimensions
of the pile cap with the corners removed.
7. Pile Allowable Load is tabulated in tons, (D + Lfloor), as is usually done in accepted practice. The
range shown, 40 tons to 400 tons, covers the usual range for precast concrete or structural steel piles.
An average load factor of is provided by the user.
8. For pile caps with 2, 3, 4, 5, 6, 7, or 9 piles, all reinforcing bars must be provided with standard
end hooks. For pile caps with 8, 10, 11, or 12 piles, only the short reinforcing bars must be provided with
end hooks, and should be placed as the lower layer. As an alternative to hooked bars, the bar ends can be headed.
9. This program contains numerous “comment boxes” which contain a wide variety of information including
explanations of input or output items, equations used, data tables, etc. (Note: presence of a “comment box”
is denoted by a “red triangle” in the upper right-hand corner of a cell. Merely move the mouse pointer to the
desired cell to view the contents of that particular "comment box".)
10.The limit states listed in the output section of each worksheet are defined and shown graphically
in the CRSI Pile Cap Design Guide.

Terms Used in the Input Section of the Worksheets:


Pile Type - concrete, steel, or wood piling may be selected
Pile Shape - round or square piles may be selected; H-piles are considered square piles (see CRSI Pile Cap
Design Guide); pipe piles are considered round piles (see CRSI Pile Cap Design Guide)
f'c - 28 day strength of concrete (limited to any value between 3,000 to 6,000 psi)
fy - yield strength of steel reinforcement; limited any value between 60 ksi and 80 ksi
Accidential Pile Offset - pile location tolerence; increases shear and bending demands on pile cap;
minimum set as CRSI recommended value of 3 in.; maximum value arbitrarily set at 24 in.
Pile Allowable Load (ASD) - Allowable compressive load on pile (provided by geotechnical engineer). Ultimate pile
load (as determined by geotechnical engineers) are typically 1.6 to 2.0 times the ASD allowable load.
Values between 20 tons and 550 tons may be selected.
Minimum Pile Embedment - the minimum pile embedment is set at 6 in. for steel piles and 4 in. for concrete
and wood piles.
Clear Cover Over Top of Pile - the clear distance from the top of the pile to the first layer of reinforcement;
the minimum value is set as the CRSI recommended minimum of 3 in.; the maximum value is arbitrarily set at 5 in.
Minimum Pile Dimension dp - is the pile diameter for round columns and the pile side dimension for square piles
L - center to center pile spacing; minimum set by CRSI recommendations; see comment box
E - minimum edge distance from center of pile to edge of concrete; set by CRSI recommendations (see comment
box)
Dmin,recommended - minimum recommended pile cap thickness based on limit state P4 (CRSI Pile Cap Design Guide)
D - user selected pile cap thickness; all resulting limit state design checks must be "ok"
A - minimum pile cap width (long direction); automatically calculated based on pile spacing and edge distance
B - minimum pile cap width (short direction); automatically calculated based on pile spacing and edge distance
Short Bars Size (No.) - selected reinforcement size for bars spanning in the "B" direction
Long Bars Size (No.) - selected reinforcement size for bars spanning in the "A" direction
dshort bars - effective depth of concrete from top of cap to center of short bars (automatically calculated)
dlong bars - effective depth of concrete from top of cap to center of long bars (automatically calculated)
dshear checks - the effective depth of the concrete for shear limit states; based on the Minimum Pile Embedment
plus the Clear Cover Over Top of Pile plus 1 inch; for steel piles the value is D minus 10 in.; for concrete/wood piles
the value is D minus 8 in. (automatically calcuated)
Special Notes for Comparing Program Output with Tabulated Designs in Pile Cap Design Guide:
1. For the 2 Pile Cap, the previous CRSI Design Handbook (2008) added an extra degree of conservatism when
determining the one way shear nominal strength. Pile cap instability (weak axis) and one way action were
considerations. The CRSI Pile Cap Design Guide (2015) and this software program also include this extra
conservatism. See 2 Pile Cap tab and Limit State 5 calculations for more information.
2. For the 3 Pile Cap, one way shear is possible on either side of the column (i.e., with 1 pile or 2 piles causing
demand and and reduced area towards the pile). The program considers both conditions and presents the worst
case results.
3. For pile caps with different distances w when considering orthogonal action and two way shear (e.g., 6 Pile Cap
and 8 Pile Cap), the program uses a slightly more conservative approach than the previous CRSI Design Handbook
(2008) for determining the nominal shear strength for Limit State 4. The previous approach used the average
w value (considering both directions) where this program uses the average demand capacity ratio for each w.
4. CRSI Limit State P4 is very restrictive for thicker pile caps and may not be entirely applicable in some cases.
The spreadsheet conservatively applies it to all caps with corner piles but assumes the one way shear strength
is limited to 2(fc')1/2 which is very conservative when the critical distance from the cap is limited to 13 in.
As a result, the design guide review committee has reviewed the results for the tabulated designs and believes that
increasing the one way shear strength to 3(f c')1/2 is still conservative for these configurations.
"CRSI-PILECAP" Program
Version 1.0

2 PILE CAP (Traditional CRSI Approach) ###


for Vertical Loading ###
Per ACI 318-11 Building Code ###
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Load Factor = 1.6 ###
Pile Type = Steel Bar No.
Pile Shape = Round ###
Concrete Comp. Strength, f'c= 3 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 120 tons ###
Pile Allowable Load (ASD) = 240 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 12 in. shown above. Actual dimensions ###
Pile Spacing, L= 3 ft. provided to the left referencing ###
Pile Edge Distance, E= 21 figure below. Short hook
in.
Pile Cap Dmin, recommended= 35 in. Long hook a
Pile Cap Dcap= 43 in. ###
Pile Cap Dimension A= 6.5 ft. ###
Pile Cap Dimension B= 3.5 ft. ###
Short Bars Size (No.) = 4
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 32.340 in.
Reinf. Effective dlong bars = 33.295 in. ###
Reinf. Effective dshear checks = 33 in.
###
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? NG; select smaller bar size ###
CRSI Limit State 1 Adequate? OK ###
CRSI Limit State 2 Adequate? OK ###
CRSI Limit State 3 Adequate? Not applicable to this pilecap configuration ###
CRSI Limit State 4 Adequate? Not applicable to this pilecap configuration ###
CRSI Limit State 5 Adequate? NG ###
CRSI Limit State 6 Adequate? Not applicable to this pilecap configuration ###
Results: ###
Column Size Determination ###
Net Column Capacity Pu= 748.44 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 13.679 in.

5 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 14 in.


(continued)

6 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 0 k-in. Total moment on pile cap with offset
Mu= 0 k-in./ft 1 ft strip design
d= 32.340 in.
As,required,structural,per ft= 0.003 in2/ft
As,required,structural,total= 0.021 in2
(4/3)As,required,structural,total= 0.027 in2
1/2
As,min,1=3(f'c) bwd/fy= 6.908 in2
As,min,2=200bwd/fy= 8.408 in2
As,min,1 or 2, controlling= 8.408 in2
As,min,3=(0.0018 or 0.002)Ag= 6.037 in2
As,required=
6.037 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.857
g s= 0.700 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 0.027 in2
As,required= 6.037 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
y e= 1 Use 1.0 for no epoxy coating
ldh= 7.668 in. OK; sufficient length available to develop hook
Req. number of short bars = 30.75
Prov. number of short bars = 8

Required Flexural Reinforcement - Long Bars


Mu= 6561.94 k-in. Total moment on pile cap with offset
Mu= 1874.84 k-in./ft 1 ft strip design
d= 33.295 in.
As,required,structural,per ft= 1.081 in2/ft
As,required,structural,total= 3.784 in2
(4/3)As,required,structural,total= 5.045 in2
As,min,1=3(f'c)1/2bwd/fy= 3.830 in2
As,min,2=200bwd/fy= 4.661 in2
As,min,1 or 2, controlling= 4.661 in2
As,min,3=(0.0018 or 0.002)Ag= 3.251 in2
As,required= 4.661 in2
E'=E-Offset = 18.00 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 21.624 in. NG; insufficient length available to develop hook
Req. number of long bars = 2.99
Prov. number of long bars = 8

7 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

(continued)

8 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - ###
d= 33.000 in. ###
d/2= 16.500 in. ###
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 219.09 psi
b0= 84.00 in. Limit State A
0.5
Vc= 607.31 kips based on Vc=4(fc') b0d acting at d/2 from column face
f Vc= 455.49 kips
Vu= -6.37 kips reduced by weight of concrete outside of critical section
Vu/f Vc -0.014
=
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - ###
d= 33.000 in. ###
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi Limit State A
bd= 1386.00 in2

Vc= 151.83 kips based on Vc=2(fc')0.5bd acting at d from column face


fVc= 113.87 kips
Vu= 0.25 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.002

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 33.295 in.
w'= 14 in.
w'/d= 0.420 OK, this limit state should be checked
Vu= 375.97 kips Limit State A
Mu= 5247.57 k-in.
Vud/Mu= 2.385
Mu/(Vud)= 0.419
k= 10
fVc= 574.45 kips
Vu/f Vc= 0.654
Conservatively assuming w'/d=1.0,
Vud/Mu= 2.385
Mu/(Vud)= 0.419
k= 5.244
fVc= 301.22 kips
Vu/f Vc= 1.248

9 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

(continued)

10 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 3.02 CY

Short Steel Bar Summary:


8 Total #4 Bars of length 3.000 ft (per bar)
16 Total Hooks of length 0.565 ft (per bar)
Weight = 22.1 lbs
Long Steel Bar Summary:
8 Total #11 Bars of length 6.000 ft (per bar)
16 Total Hooks of length 1.728 ft (per bar)
Weight = 401.9 lbs

Total weight of all steel = 424.0 lbs or 0.212 tons

Comments:

11 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

3 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 550 tons
Pile Allowable Load (ASD) = 1100 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
shown above. Actual dimensions
Minimum Pile Dimension dp= 20 in. provided to the left referencing
Pile Spacing, L= 5 ft. figure below.
Pile Edge Distance, E= 36 in.
Pile Cap Dmin, recommended= 99.5 in. A'= 3.464 ft.
Pile Cap Dcap= 66 in. B'= 3.804 ft.
Pile Cap Dimension A= 11 ft.
Pile Cap Dimension B= 10.33 ft.
Bar Size (No.)= 11
(All Three Directions)
Reinf. Effective dshort bars = 56.295 in.
Reinf. Effective dlong bars = 57 in.
Reinf. Effective dshear checks = 56 in.
High capacity pile selected - special details required - see CRSI Pile Cap Design Guide
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? Not Applicable CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? NG
CRSI Limit State 4 Adequate? NG CRSI Limit State P3 Adequate? NG
CRSI Limit State 5 Adequate? Not Applicable CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? #DIV/0!
Results:
Column Size Determination
Net Column Capacity Pu= 5162.47 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 40.538 in.

12 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 41 in.


(continued)

13 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Three Ways


Mu= 32869.17 k-in. Total moment on pile cap with offset
Mu= 8641.37 k-in./ft 1 ft strip design
d= 56.295 in.
As,required,structural,per ft= 3.007 in2/ft
As,required,structural,total= 11.439 in2
(4/3)As,required,structural,total= 15.252 in2
1/2
As,min,1=3(f'c) bwd/fy= 7.037 in2
As,min,2=200bwd/fy= 8.565 in2
As,min,1 or 2, controlling= 8.565 in2
As,min,3=(0.0018 or 0.002)Ag= 5.423 in2
As,required= 11.439 in2
E'=E-Offset = 33 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 21.624 in. OK; sufficient length available to develop hook
Req. number of short bars = 7.33
Prov. number of short bars = 4

(continued)

14 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 56 in.
d/2= 28 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 219.09 psi
b0= 304.73 in.
Vc= 3738.67 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2804.00 kips
Vu= -100.60 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.036

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 56.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 1948.90 in2
Vc= 213.49 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 160.12 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000

(continued)

15 of 228 09/13/2020 12:25:56


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 56.000 in.
d/2= 28.000 in.
No. of piles outside face of the column = 3
wactual= 17.142 in. < d/2 This procedure applies
Vu= 5174.57 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 304.726 in.
bs= 128.802 in.
k= 15.458 based on k=2(d/w)(1+d/c) acting at column face
Vc= 6106.79 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 4580.09 kips
Vu/f Vc= 1.130

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 54.885 in.
w'= 17.120 in.
w'/d= 0.312 OK, this limit state should be checked
Vu= 1760.00 kips
Mu= 30131.20 k-in.
Vud/Mu= 3.206
Mu/(Vud)= 0.312
k= 10.000
fVc= 2242.54 kips
Vu/f Vc= 0.785 Above #DIV/0! Below #DIV/0! Controlling
(continued)

16 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 18.14 CY

All Steel Bar Summary:


12 Total #11 Bars of length 10.500 ft (per bar)
24 Total Hooks of length 1.728 ft (per bar)
Weight = 889.8 lbs

Total weight of all steel = 889.8 lbs or 0.445 tons

Comments:

17 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

18 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

4 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 550 tons
Pile Allowable Load (ASD) = 1100 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 5 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 36 in.
Pile Cap Dmin, recommended= 99.5 in.
Pile Cap Dcap= 67 in.
Pile Cap Dimension A= 11 ft.
Pile Cap Dimension B= 11 ft.
Short Bars Size (No.) = 14
Long Bars Size (No.) = 14
Reinf. Effective dshort bars = 55.461 in.
Reinf. Effective dlong bars = 57.154 in.
Reinf. Effective dshear checks = 57 in.
High capacity pile selected - special details required - see CRSI Pile Cap Design Guide
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? NG
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? NG
CRSI Limit State 5 Adequate? NG CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? NG
Results:
Column Size Determination
Net Column Capacity Pu= 6877.86 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 41.466 in.

19 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 42 in.


(continued)

20 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 77308.21 k-in. Total moment on pile cap with offset
Mu= 7028.02 k-in./ft 1 ft strip design
d= 55.461 in.
As,required,structural,per ft= 2.461 in2/ft
As,required,structural,total= 27.066 in2
(4/3)As,required,structural,total= 36.088 in2
1/2
As,min,1=3(f'c) bwd/fy= 20.049 in2
As,min,2=200bwd/fy= 24.403 in2
As,min,1 or 2, controlling= 24.403 in2
As,min,3=(0.0018 or 0.002)Ag= 15.919 in2
As,required=
27.066 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
gs= 1.000 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 27.066 in2
As,required= 27.066 in2
E'=E-Offset = 33 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of short bars = 12.02
Prov. number of short bars = 11

Required Flexural Reinforcement - Long Bars


Mu= 77308.21 k-in. Total moment on pile cap with offset
Mu= 7028.02 k-in./ft 1 ft strip design
d= 57.1535 in.
As,required,structural,per ft= 2.381 in2/ft
As,required,structural,total= 26.195 in2
(4/3)As,required,structural,total= 34.927 in2
As,min,1=3(f'c)1/2bwd/fy= 20.661 in2
As,min,2=200bwd/fy= 25.148 in2
As,min,1 or 2, controlling= 25.148 in2
As,min,3=(0.0018 or 0.002)Ag= 15.919 in2
As,required= 26.195 in2
E'=E-Offset = 33.00 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of long bars = 11.64
Prov. number of long bars = 11

21 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

(continued)

22 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 57.000 in.
d/2= 28.500 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 219.09 psi
b0= 396.00 in.
Vc= 4945.28 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3708.96 kips
Vu= -70.94 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.019

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 57.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 7524.00 in2
Vc= 824.21 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 618.16 kips
Vu= 14.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.024

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 57.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 7524.00 in.
Vc= 824.21 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 618.16 kips
Vu= 14.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.024

(continued)

23 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 57.000 in.
d/2= 28.500 in.
No. of piles outside face of the column = 4
wactual= 12.000 in. < d/2 This procedure applies
Vu= 6894.28 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 396.000 in.
bs= 168.000 in.
k= 22.393 based on k=2(d/w)(1+d/c) acting at column face
Vc= 11745.03 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 8808.78 kips
Vu/f Vc= 0.783

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 57.1535 in.
w'= 12.000 in.
w'/d= 0.210 OK, this limit state should be checked
Vu= 3464.73 kips
Mu= 40996.31 k-in.
Vud/Mu= 4.830
Mu/(Vud)= 0.207
k= 10.000
fVc= 3099.12 kips
Vu/f Vc= 1.118

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 55.4605 in.
w'= 12.000 in.
w'/d= 0.216 OK, this limit state should be checked
Vu= 3464.73 kips
Mu= 40996.31 k-in.
Vud/Mu= 4.687
Mu/(Vud)= 0.213
k= 10.000
fVc= 3007.32 kips
Vu/f Vc= 1.152

24 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

(continued)

25 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 25.02 CY

Short Steel Bar Summary:


11 Total #14 Bars of length 10.500 ft (per bar)
22 Total Hooks of length 2.075 ft (per bar)
Weight = 1234.4 lbs
Long Steel Bar Summary:
11 Total #14 Bars of length 10.500 ft (per bar)
22 Total Hooks of length 2.075 ft (per bar)
Weight = 1234.4 lbs

Total weight of all steel = 2468.8 lbs or 1.234 tons

Comments:

26 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

27 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

5 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 120 tons
Pile Allowable Load (ASD) = 240 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in. Note: Minimum cap dimensions
shown above. Actual dimensions
Minimum Pile Dimension dp= 12 in. provided to the left referencing
Pile Spacing, L= 3 ft. figure below.
Pile Edge Distance, E= 21 in.
Pile Cap Dmin, recommended= 35 in.
Pile Cap Dcap= 43 in.
Pile Cap Dimension A= 7.7426 ft.
Pile Cap Dimension B= 7.7426 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 32.095 in.
Reinf. Effective dlong bars = 33.365 in.
Reinf. Effective dshear checks = 33 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size
CRSI Limit State 1 Adequate? NG
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1868.44 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.613 in.

28 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 22 in.


(continued)

29 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 17164.53 k-in. Total moment on pile cap with offset
Mu= 2216.89 k-in./ft 1 ft strip design
d= 32.095 in.
As,required,structural,per ft= 1.338 in2/ft
As,required,structural,total= 10.357 in2
(4/3)As,required,structural,total= 13.810 in2
As,min,1=3(f'c)1/2bwd/fy= 8.167 in2
As,min,2=200bwd/fy= 9.940 in2
As,min,1 or 2, controlling= 9.940 in2
As,min,3=(0.0018 or 0.002)Ag= 7.191 in2
As,required=
10.357 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
gs= 1.000 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 10.357 in2
As,required= 10.357 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 19.477 in. NG; insufficient length available to develop hook
Req. number of short bars = 8.18
Prov. number of short bars = 14

Required Flexural Reinforcement - Long Bars


Mu= 17164.53 k-in. Total moment on pile cap with offset
Mu= 2216.89 k-in./ft 1 ft strip design
d= 33.365 in.
As,required,structural,per ft= 1.283 in2/ft
As,required,structural,total= 9.932 in2
(4/3)As,required,structural,total= 13.243 in2
As,min,1=3(f'c)1/2bwd/fy= 8.490 in2
As,min,2=200bwd/fy= 10.333 in2
As,min,1 or 2, controlling= 10.333 in2
As,min,3=(0.0018 or 0.002)Ag= 7.191 in2
As,required= 10.333 in2
E'=E-Offset = 18.00 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 19.477 in. NG; insufficient length available to develop hook
Req. number of long bars = 8.16

30 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 14


(continued)

31 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 33.000 in.
d/2= 16.500 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 219.09 psi
b0= 220.00 in.
Vc= 1590.59 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1192.94 kips
Vu= 1502.51 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 1.260

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 33.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 3066.07 in2
Vc= 335.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 251.90 kips
Vu= -1.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.005

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 33.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 3066.07 in.
Vc= 335.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 251.90 kips
Vu= -1.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.005

(continued)

32 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 33.000 in.
d/2= 16.500 in.
No. of piles outside face of the column = 4
wactual= 17.456 in. > d/2 Limit state not applicable
Vu= 1487.34 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 220.000 in.
bs= 88.000 in.
k= 9.453 based on k=2(d/w)(1+d/c) acting at column face
Vc= 1503.51 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1127.63 kips
Vu/f Vc= 1.319

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 33.365 in.
w'= 17.456 in.
w'/d= 0.523 OK, this limit state should be checked
Vu= 748.33 kips
Mu= 13057.13 k-in.
Vud/Mu= 1.912
Mu/(Vud)= 0.523
k= 8.764
fVc= 1116.09 kips
Vu/f Vc= 0.670

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 32.095 in.
w'= 17.456 in.
w'/d= 0.544 OK, this limit state should be checked
Vu= 748.33 kips
Mu= 13057.13 k-in.
Vud/Mu= 1.839
Mu/(Vud)= 0.544
k= 8.203
fVc= 1004.86 kips
Vu/f Vc= 0.745

33 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

(continued)

34 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 7.96 CY

Short Steel Bar Summary:


14 Total #10 Bars of length 7.243 ft (per bar)
28 Total Hooks of length 1.557 ft (per bar)
Weight = 624.9 lbs
Long Steel Bar Summary:
14 Total #10 Bars of length 7.243 ft (per bar)
28 Total Hooks of length 1.557 ft (per bar)
Weight = 624.9 lbs

Total weight of all steel = 1249.8 lbs or 0.625 tons

Comments:

35 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

36 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

6 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 550 tons
Pile Allowable Load (ASD) = 1100 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 5 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 36 in.
Pile Cap Dmin, recommended= 99.5 in.
Pile Cap Dcap= 85 in.
Pile Cap Dimension A= 16 ft.
Pile Cap Dimension B= 11 ft.
Short Bars Size (No.) = 14
Long Bars Size (No.) = 14
Reinf. Effective dshort bars = 73.461 in.
Reinf. Effective dlong bars = 75.154 in.
Reinf. Effective dshear checks = 75 in.
High capacity pile selected - special details required - see CRSI Pile Cap Design Guide
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? NG
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NG CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 10260.80 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 50.648 in.

37 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 51 in.


(continued)

38 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 103706.36 k-in. Total moment on pile cap with offset
Mu= 6481.65 k-in./ft 1 ft strip design
d= 73.461 in.
As,required,structural,per ft= 1.680 in2/ft
As,required,structural,total= 26.876 in2
(4/3)As,required,structural,total= 35.835 in2
As,min,1=3(f'c)1/2bwd/fy= 38.627 in2
As,min,2=200bwd/fy= 47.015 in2
As,min,1 or 2, controlling= 47.015 in2
As,min,3=(0.0018 or 0.002)Ag= 29.376 in2
As,required=
35.835 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.455
gs= 0.815 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 31.853 in2
As,required= 35.835 in2
E'=E-Offset = 33 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of short bars = 15.92
Prov. number of short bars = 13

Required Flexural Reinforcement - Long Bars


Mu= 171479.94 k-in. Total moment on pile cap with offset
Mu= 15589.09 k-in./ft 1 ft strip design
d= 75.1535 in.
As,required,structural,per ft= 4.067 in2/ft
As,required,structural,total= 44.733 in2
(4/3)As,required,structural,total= 59.644 in2
As,min,1=3(f'c)1/2bwd/fy= 27.168 in2
As,min,2=200bwd/fy= 33.068 in2
As,min,1 or 2, controlling= 33.068 in2
As,min,3=(0.0018 or 0.002)Ag= 20.196 in2
As,required= 44.733 in2
E'=E-Offset = 33.00 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of long bars = 19.87

39 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 15


(continued)

40 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 75.000 in.
d/2= 37.500 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 219.09 psi
b0= 504.00 in.
Vc= 8281.57 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 6211.17 kips
Vu= 6928.23 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 1.115

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 75.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 9900.00 in2
Vc= 1084.49 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 813.37 kips
Vu= 7.01 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.009

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 75.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 14400.00 in.
Vc= 1577.44 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1183.08 kips
Vu= 78.20 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.066

(continued)

41 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 75.000 in.

d/2= 37.500 in.


No. of piles outside face of the column = 6
wactual= 7.500 in. < d/2 This procedure applies
Vu= 10291.51 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 504.000 in.
bs= 204.000 in.

k= 32.000 based on k=2(d/w)(1+d/c) acting at column face


Vc= 26816.50 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 20112.37 kips
Vu/f Vc= 0.512 ****COMBINED**** Vu/f Vc= 1.084

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 75.1535 in.
w'= 37.500 in.
w'/d= 0.499 OK, this limit state should be checked
Vu= 3410.14 kips
Mu= 128127.35 k-in.
Vud/Mu= 2.000
Mu/(Vud)= 0.500
k= 9.470
fVc= 3859.20 kips
Vu/f Vc= 0.884

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 73.4605 in.
w'= 7.500 in.
w'/d= 0.102 OK, this limit state should be checked
Vu= 5188.20 kips
Mu= 37741.05 k-in.
Vud/Mu= 10.098
Mu/(Vud)= 0.099
k= 10.000
fVc= 5793.98 kips

42 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= 0.895


(continued)

43 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 46.17 CY

Short Steel Bar Summary:


13 Total #14 Bars of length 10.500 ft (per bar)
26 Total Hooks of length 2.075 ft (per bar)
Weight = 1458.8 lbs
Long Steel Bar Summary:
15 Total #14 Bars of length 15.500 ft (per bar)
30 Total Hooks of length 2.075 ft (per bar)
Weight = 2257.8 lbs

Total weight of all steel = 3716.6 lbs or 1.858 tons

Comments:

44 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

45 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

7 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in.
Pile Cap Dcap= 84 in.
Pile Cap Dimension A= 14.5 ft.
Pile Cap Dimension B= 12.8932 ft.
Short Bars Size (No.) = 14
Long Bars Size (No.) = 14
Reinf. Effective dshort bars = 72.461 in.
Reinf. Effective dlong bars = 74.154 in.
Reinf. Effective dshear checks = 74 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? NA
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 581.92 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 13.610 in.

46 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 14 in. DIAMETER FOR 7 PILE CAP


(continued)

47 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 10298.95 k-in. Total moment on pile cap with offset
Mu= 710.27 k-in./ft 1 ft strip design
d= 72.461 in.
As,required,structural,per ft= 0.203 in2/ft
As,required,structural,total= 2.949 in2
(4/3)As,required,structural,total= 3.932 in2
As,min,1=3(f'c)1/2bwd/fy= 39.870 in2
As,min,2=200bwd/fy= 42.027 in2
As,min,1 or 2, controlling= 42.027 in2
As,min,3=(0.0018 or 0.002)Ag= 26.309 in2
As,required=
26.309 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.125
gs= 0.941 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 3.122 in2
As,required= 26.309 in2
E'=E-Offset = 12 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 22.486 in. NG; insufficient length available to develop hook
Req. number of short bars = 11.69
Prov. number of short bars = 11

Required Flexural Reinforcement - Long Bars


Mu= 11947.38 k-in. Total moment on pile cap with offset
Mu= 926.64 k-in./ft 1 ft strip design
d= 74.1535 in.
As,required,structural,per ft= 0.254 in2/ft
As,required,structural,total= 3.275 in2
(4/3)As,required,structural,total= 4.366 in2
As,min,1=3(f'c)1/2bwd/fy= 36.281 in2
As,min,2=200bwd/fy= 38.243 in2
As,min,1 or 2, controlling= 38.243 in2
As,min,3=(0.0018 or 0.002)Ag= 23.393 in2
As,required= 23.393 in2
E'=E-Offset = 12.00 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 22.486 in. NG; insufficient length available to develop hook
Req. number of long bars = 10.39

48 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 11


(continued)

49 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 74.000 in.
d/2= 37.000 in.
No. of piles outside d/2 from face of the column = 6
4(fc')0.5= 252.98 psi
b0= 276.46 in.
Vc= 5175.52 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3881.64 kips
Vu= 524.88 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.135

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 74.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 11449.16 in2
Vc= 1448.22 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1086.16 kips
Vu= -10.83 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.010

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 74.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 12876.00 in.
Vc= 1628.70 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1221.52 kips
Vu= 7.39 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.006

(continued)

50 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 74.000 in.
d/2= 37.000 in.
No. of piles outside face of the column = 6
wactual= 68.000 in. > d/2 Limit state not applicable
Vu= 456.21 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 276.452 in.
bs= 43.981 in.
k= 13.681 based on k=2(d/w)(1+d/c) acting at column face
Vc= 2816.01 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 2112.01 kips
Vu/f Vc= 0.216

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 74.1535 in.
w'= 32.000 in.
w'/d= 0.432 OK, this limit state should be checked
Vu= 239.60 kips
Mu= 11119.85 k-in.
Vud/Mu= 1.598
Mu/(Vud)= 0.626
k= 9.237
fVc= 5027.11 kips
Vu/f Vc= 0.048

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 72.4605 in.
w'= 58.359 in.
w'/d= 0.805 OK, this limit state should be checked
Vu= 113.17 kips
Mu= 9915.28 k-in.
Vud/Mu= 0.827
Mu/(Vud)= 1.209
k= 1.175
fVc= 702.58 kips
Vu/f Vc= 0.161

51 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

(continued)

52 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 48.47 CY

Short Steel Bar Summary:


11 Total #14 Bars of length 12.393 ft (per bar)
22 Total Hooks of length 2.075 ft (per bar)
Weight = 1393.9 lbs
Long Steel Bar Summary:
11 Total #14 Bars of length 14.000 ft (per bar)
22 Total Hooks of length 2.075 ft (per bar)
Weight = 1529.3 lbs

Total weight of all steel = 2923.2 lbs or 1.462 tons

Comments:

53 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

54 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

8 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in. Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 shown above. Actual dimensions
in.
provided to the left referencing
Pile Spacing, L= 6 ft. figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in.
Pile Cap Dcap= 51 in.
Pile Cap Dimension A= 14.5 ft.
Pile Cap Dimension B= 12.8932 ft.
Short Bars Size (No.) = 9
Long Bars Size (No.) = 8
Reinf. Effective dshort bars = 40.436 in.
Reinf. Effective dlong bars = 41.500 in.
Reinf. Effective dshear checks = 41 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 833.31 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 14.434 in.

55 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 15 in.


(continued)

56 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 20316.13 k-in. Total moment on pile cap with offset
Mu= 1401.11 k-in./ft 1 ft strip design
d= 40.436 in.
As,required,structural,per ft= 0.662 in2/ft
As,required,structural,total= 9.598 in2
(4/3)As,required,structural,total= 12.797 in2
1/2
As,min,1=3(f'c) bwd/fy= 22.249 in2
As,min,2=200bwd/fy= 23.453 in2
As,min,1 or 2, controlling= 23.453 in2
As,min,3=(0.0018 or 0.002)Ag= 15.973 in2
As,required=
15.973 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.125
gs= 0.941 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 10.161 in2
As,required= 15.973 in2
E'=E-Offset = 12 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 14.982 in. NG; insufficient length available to develop hook
Req. number of short bars = 15.98
Prov. number of short bars = 15

Required Flexural Reinforcement - Long Bars


Mu= 18954.32 k-in. Total moment on pile cap with offset
Mu= 1470.10 k-in./ft 1 ft strip design
d= 41.5 in.
As,required,structural,per ft= 0.677 in2/ft
As,required,structural,total= 8.725 in2
(4/3)As,required,structural,total= 11.633 in2
As,min,1=3(f'c)1/2bwd/fy= 20.304 in2
As,min,2=200bwd/fy= 21.403 in2
As,min,1 or 2, controlling= 21.403 in2
As,min,3=(0.0018 or 0.002)Ag= 14.203 in2
As,required= 14.203 in2
E'=E-Offset = 12.00 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 13.282 in. NG; insufficient length available to develop hook
Req. number of long bars = 18.08
Prov. number of long bars = 14

57 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

(continued)

58 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 41.000 in.
d/2= 20.500 in.
No. of piles outside d/2 from face of the column = 8
4(fc')0.5= 252.98 psi
b0= 224.00 in.
Vc= 2323.39 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1742.54 kips
Vu= 855.52 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.491

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 41.000 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 126.49 psi
bd= 6343.45 in2
Vc= 802.39 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 601.79 kips
Vu= 213.81 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.355

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 41.000 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 126.49 psi
bd= 7134.00 in.
Vc= 902.39 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 676.79 kips
Vu= 348.43 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.515

(continued)

59 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 41.000 in.

d/2= 20.500 in.


No. of piles outside face of the column = 8
wactual= 31.500 in. > d/2 Limit state not applicable
Vu= 834.90 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 224.000 in.
bs= 60.000 in.

k= 9.719 based on k=2(d/w)(1+d/c) acting at column face


Vc= 1512.05 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1134.03 kips
Vu/f Vc= 0.736 ****COMBINED**** Vu/f Vc= 1.044

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 41.5 in.
w'= 31.500 in.
w'/d= 0.759 OK, this limit state should be checked
Vu= 296.87 kips
Mu= 17848.75 k-in.
Vud/Mu= 0.690
Mu/(Vud)= 1.449
k= -0.316
fVc= -96.25 kips
Vu/f Vc= -3.084

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 40.436 in.
w'= 57.852 in.
w'/d= 1.431 Limit state not applicable
Vu= 297.90 kips
Mu= 19207.68 k-in.
Vud/Mu= 0.627
Mu/(Vud)= 1.595
k= -0.667
fVc= -222.68 kips

60 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= -1.338


(continued)

61 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 29.43 CY

Short Steel Bar Summary:


15 Total #9 Bars of length 12.393 ft (per bar)
30 Total Hooks of length 1.383 ft (per bar)
Weight = 773.2 lbs
Long Steel Bar Summary:
14 Total #8 Bars of length 14.000 ft (per bar)
28 Total Hooks of length 1.047 ft (per bar)
Weight = 602.2 lbs

Total weight of all steel = 1375.3 lbs or 0.688 tons

Comments:

62 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

63 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

9 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Load Factor = 1.6 ###
Pile Type = Steel Bar No.
Pile Shape = Round ###
Concrete Comp. Strength, f'c= 4 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 40 tons ###
Pile Allowable Load (ASD) = 80 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions ###
Pile Spacing, L= 6 provided to the left referencing ###
ft.
figure below.
Pile Edge Distance, E= 15 in. Short hook
Pile Cap Dmin, recommended= 23 in. Long hook a
Pile Cap Dcap= 90 in. Short Bar D
Pile Cap Dimension A= 14.5 ft. Short Bar Ar
Pile Cap Dimension B= 14.5 ft. Steel pile em
Short Bars Size (No.) = 14
Long Bars Size (No.) = 14
Reinf. Effective dshort bars = 78.461 in.
Reinf. Effective dlong bars = 80.154 in. If given pile
Reinf. Effective dshear checks = 80 in.
Equivalent P
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size d=
CRSI Limit State 1 Adequate? OK d/2=
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK Diameter fo
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK Area in shea
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK 4(fc')0.5=
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK Vc=
CRSI Limit State 6 Adequate? OK
Results: Vu=
Column Size Determination Vu/f Vc=
Net Column Capacity Pu= 773.55 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 13.906 in.

64 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 14 in.


(continued)

65 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 19873.68 k-in. Total moment on pile cap with offset
Mu= 1370.60 k-in./ft 1 ft strip design
d= 78.461 in.
As,required,structural,per ft= 0.348 in2/ft
As,required,structural,total= 5.044 in2
(4/3)As,required,structural,total= 6.726 in2
1/2
As,min,1=3(f'c) bwd/fy= 43.172 in2
As,min,2=200bwd/fy= 45.507 in2
As,min,1 or 2, controlling= 45.507 in2
As,min,3=(0.0018 or 0.002)Ag= 28.188 in2
As,required=
28.188 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
gs= 1.000 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 5.044 in2
As,required= 28.188 in2
E'=E-Offset = 12 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 22.486 in. NG; insufficient length available to develop hook
Req. number of short bars = 12.52
Prov. number of short bars = 18

Required Flexural Reinforcement - Long Bars


Mu= 19873.68 k-in. Total moment on pile cap with offset
Mu= 1370.60 k-in./ft 1 ft strip design
d= 80.1535 in.
As,required,structural,per ft= 0.341 in2/ft
As,required,structural,total= 4.952 in2
(4/3)As,required,structural,total= 6.602 in2
As,min,1=3(f'c)1/2bwd/fy= 44.103 in2
As,min,2=200bwd/fy= 46.489 in2
As,min,1 or 2, controlling= 46.489 in2
As,min,3=(0.0018 or 0.002)Ag= 28.188 in2
As,required= 28.188 in2
E'=E-Offset = 12.00 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 22.486 in. NG; insufficient length available to develop hook
Req. number of long bars = 12.52
Prov. number of long bars = 18

66 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

(continued)

67 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - distance fro
d= 80.000 in. distance fro
d/2= 40.000 in. distance fro
No. of piles outside d/2 from face of the column = 8
4(fc')0.5= 252.98 psi
b0= 376.00 in. Limit State A
0.5
Vc= 7609.70 kips based on Vc=4(fc') b0d acting at d/2 from column face
fVc= 5707.28 kips
Vu= 756.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.132

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - distance fro
d= 80.000 in. distance fro
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi Limit State A
bd= 13920.00 in2

Vc= 1760.76 kips based on Vc=2(fc')0.5bd acting at d from column face


fVc= 1320.57 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 - distance fro
d= 80.000 in. distance fro
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi Limit State A
bd= 13920.00 in.
Vc= 1760.76 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1320.57 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000

(continued)

68 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 80.000 in.
d/2= 40.000 in.
No. of piles outside face of the column = 8
wactual= 68.000 in. > d/2 Limit state not applicable
Vu= 648.00 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 376.000 in. Limit State A
bs= 56.000 in.
k= 15.798 based on k=2(d/w)(1+d/c) acting at column face
Vc= 4476.30 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 3357.22 kips
Vu/f Vc= 0.193

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 80.1535 in.
w'= 68.000 in.
w'/d= 0.848 OK, this limit state should be checked
Vu= 210.00 kips
Mu= 19152.00 k-in. Limit State A
Vud/Mu= 0.879
Mu/(Vud)= 1.138
k= 1.536
fVc= 1016.05 kips
Vu/f Vc= 0.207

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 78.4605 in.
w'= 68.000 in.
w'/d= 0.867 OK, this limit state should be checked
Vu= 210.00 kips
Mu= 19152.00 k-in. Limit State A
Vud/Mu= 0.860
Mu/(Vud)= 1.162
k= 1.361
fVc= 881.58 kips
Vu/f Vc= 0.238

69 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

(continued)

70 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars d=


Concrete Summary: d/2=
Quantity = 58.40 CY Diameter fo
Area in shea
Short Steel Bar Summary: 4(fc')0.5=
18 Total #14 Bars of length 14.000 ft (per bar) Vc=
36 Total Hooks of length 2.075 ft (per bar)
Weight = 2502.5 lbs Vu=
Long Steel Bar Summary:
18 Total #14 Bars of length 14.000 ft (per bar)
36 Total Hooks of length 2.075 ft (per bar)
Weight = 2502.5 lbs d=
d/2=
Total weight of all steel = 5005.0 lbs or 2.502 tons Straight dim
Round dime
Area in shea
Comments: 4(fc')0.5=
Vc=

Vu=

d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=

Vu=
Vu/f Vc=

d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=

71 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

72 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

10 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 20 Note: Minimum cap dimensions
in.
shown above. Actual dimensions
Pile Spacing, L= 6 ft. provided to the left referencing
Pile Edge Distance, E= 15 in. figure below.
Pile Cap Dmin, recommended= 23 in.
Pile Cap Dcap= 81 in.
Pile Cap Dimension A= 20.5 ft.
Pile Cap Dimension B= 12.8932 ft.
Short Bars Size (No.) = 14
Long Bars Size (No.) = 14
Reinf. Effective dshort bars = 69.461 in.
Reinf. Effective dlong bars = 71.154 in.
Reinf. Effective dshear checks = 71 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 851.82 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 14.593 in.

73 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 15 in.


(continued)

74 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 16157.58 k-in. Total moment on pile cap with offset
Mu= 788.17 k-in./ft 1 ft strip design
d= 69.461 in.
As,required,structural,per ft= 0.231 in2/ft
As,required,structural,total= 4.741 in2
(4/3)As,required,structural,total= 6.321 in2
1/2
As,min,1=3(f'c) bwd/fy= 54.035 in2
As,min,2=200bwd/fy= 56.958 in2
As,min,1 or 2, controlling= 56.958 in2
As,min,3=(0.0018 or 0.002)Ag= 35.867 in2
As,required=
35.867 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.590
gs= 0.772 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 5.821 in2
As,required= 35.867 in2
E'=E-Offset = 12 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 22.486 in. NG; insufficient length available to develop hook
Req. number of short bars = 15.93
Prov. number of short bars = 21

Required Flexural Reinforcement - Long Bars


Mu= 24103.97 k-in. Total moment on pile cap with offset
Mu= 1869.51 k-in./ft 1 ft strip design
d= 71.1535 in.
As,required,structural,per ft= 0.510 in2/ft
As,required,structural,total= 6.582 in2
(4/3)As,required,structural,total= 8.775 in2
As,min,1=3(f'c)1/2bwd/fy= 34.813 in2
As,min,2=200bwd/fy= 36.696 in2
As,min,1 or 2, controlling= 36.696 in2
As,min,3=(0.0018 or 0.002)Ag= 22.558 in2
As,required= 22.558 in2
cb= 3.06 in.
ld=
66.580 in.
lavailable= 112.500 in. OK; sufficient length available to develop bar
Req. number of long bars = 10.02

75 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 25


(continued)

76 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 71.000 in.
d/2= 35.500 in.
No. of piles outside d/2 from face of the column = 8
4(fc')0.5= 252.98 psi
b0= 344.00 in.
Vc= 6178.84 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 4634.13 kips
Vu= 679.02 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.147

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 71.000 in.
No. of piles outside d from face of the column = 1
2(fc')0.5= 126.49 psi
bd= 10985.01 in2
Vc= 1389.51 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1042.13 kips
Vu= 50.54 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.049

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 71.000 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 17466.00 in.
Vc= 2209.29 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1656.97 kips
Vu= 3.16 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.002

(continued)

77 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 71.000 in.

d/2= 35.500 in.


No. of piles outside face of the column = 10
wactual= 31.500 in. < d/2 This procedure applies
Vu= 854.35 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 344.000 in.
bs= 60.000 in.

k= 25.846 based on k=2(d/w)(1+d/c) acting at column face


Vc= 6963.45 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 5222.59 kips
Vu/f Vc= 0.164 ****COMBINED**** Vu/f Vc= 0.148

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 71.1535 in.
w'= 31.500 in.
w'/d= 0.443 OK, this limit state should be checked
Vu= 310.96 kips
Mu= 22950.10 k-in.
Vud/Mu= 0.964
Mu/(Vud)= 1.037
k= 4.090
fVc= 2135.61 kips
Vu/f Vc= 0.146

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 69.4605 in.
w'= 57.852 in.
w'/d= 0.833 OK, this limit state should be checked
Vu= 190.66 kips
Mu= 15462.04 k-in.
Vud/Mu= 0.857
Mu/(Vud)= 1.168
k= 1.386
fVc= 1123.16 kips

78 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= 0.170


(continued)

79 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 66.08 CY

Short Steel Bar Summary:


21 Total #14 Bars of length 12.393 ft (per bar)
0 Total Hooks of length 2.075 ft (per bar)
Weight = 1993.6 lbs
Long Steel Bar Summary:
25 Total #14 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 2.075 ft (per bar)
Weight = 3830.0 lbs

Total weight of all steel = 5823.5 lbs or 2.912 tons

Comments:

80 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

81 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

11 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in.
Pile Cap Dcap= 63 in.
Pile Cap Dimension A= 20.5 ft.
Pile Cap Dimension B= 12.8932 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 51.885 in.
Reinf. Effective dlong bars = 53.295 in.
Reinf. Effective dshear checks = 53 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? NG CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? NG
Results:
Column Size Determination
Net Column Capacity Pu= 1074.97 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 16.393 in.

82 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 17 in.


(continued)

83 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 25535.40 k-in. Total moment on pile cap with offset
Mu= 1245.63 k-in./ft 1 ft strip design
d= 51.885 in.
As,required,structural,per ft= 0.463 in2/ft
As,required,structural,total= 9.494 in2
(4/3)As,required,structural,total= 12.659 in2
1/2
As,min,1=3(f'c) bwd/fy= 40.362 in2
As,min,2=200bwd/fy= 42.546 in2
As,min,1 or 2, controlling= 42.546 in2
As,min,3=(0.0018 or 0.002)Ag= 27.896 in2
As,required=
27.896 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.590
gs= 0.772 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 11.657 in2
As,required= 27.896 in2
E'=E-Offset = 12 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 18.727 in. NG; insufficient length available to develop hook
Req. number of short bars = 17.87
Prov. number of short bars = 20

Required Flexural Reinforcement - Long Bars


Mu= 35734.75 k-in. Total moment on pile cap with offset
Mu= 2771.60 k-in./ft 1 ft strip design
d= 53.295 in.
As,required,structural,per ft= 0.993 in2/ft
As,required,structural,total= 12.802 in2
(4/3)As,required,structural,total= 17.069 in2
As,min,1=3(f'c)1/2bwd/fy= 26.075 in2
As,min,2=200bwd/fy= 27.486 in2
As,min,1 or 2, controlling= 27.486 in2
As,min,3=(0.0018 or 0.002)Ag= 17.545 in2
As,required= 17.545 in2
cb= 3.51 in.
ld=
40.331 in.
lavailable= 111.500 in. OK; sufficient length available to develop bar
Req. number of long bars = 11.24

84 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 22


(continued)

85 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 53.000 in.
d/2= 26.500 in.
No. of piles outside d/2 from face of the column = 10
4(fc')0.5= 252.98 psi
b0= 280.00 in.
Vc= 3754.26 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2815.69 kips
Vu= 989.84 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.352

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 53.000 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 126.49 psi
bd= 8200.08 in2
Vc= 1037.24 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 777.93 kips
Vu= 300.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.387

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 53.000 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 126.49 psi
bd= 13038.00 in.
Vc= 1649.19 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1236.89 kips
Vu= 477.86 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.386

(continued)

86 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 53.000 in.

d/2= 26.500 in.


No. of piles outside face of the column = 10
wactual= 30.500 in. > d/2 Limit state not applicable
Vu= 949.50 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 280.000 in.
bs= 68.000 in.

k= 14.311 based on k=2(d/w)(1+d/c) acting at column face


Vc= 3261.89 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 2446.42 kips
Vu/f Vc= 0.388 ****COMBINED**** Vu/f Vc= 0.556

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 53.295 in.
w'= 30.500 in.
w'/d= 0.572 OK, this limit state should be checked
Vu= 484.99 kips
Mu= 33685.76 k-in.
Vud/Mu= 0.767
Mu/(Vud)= 1.303
k= 0.836
fVc= 326.79 kips
Vu/f Vc= 1.484

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 51.885 in.
w'= 56.859 in.
w'/d= 1.096 Limit state not applicable
Vu= 363.78 kips
Mu= 24008.77 k-in.
Vud/Mu= 0.786
Mu/(Vud)= 1.272
k= 0.578
fVc= 349.79 kips

87 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= 1.040


(continued)

88 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 51.39 CY

Short Steel Bar Summary:


20 Total #11 Bars of length 12.393 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1316.9 lbs
Long Steel Bar Summary:
22 Total #11 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2337.8 lbs

Total weight of all steel = 3654.7 lbs or 1.827 tons

Comments:

89 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

90 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

12 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in.
Pile Cap Dcap= 48 in.
Pile Cap Dimension A= 20.5 ft.
Pile Cap Dimension B= 14.5 ft.
Short Bars Size (No.) = 6
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 37.355 in.
Reinf. Effective dlong bars = 38.365 in.
Reinf. Effective dshear checks = 38 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1250.64 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 17.682 in.

91 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 18 in.


(continued)

92 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 30514.88 k-in. Total moment on pile cap with offset
Mu= 1488.53 k-in./ft 1 ft strip design
d= 37.355 in.
As,required,structural,per ft= 0.761 in2/ft
As,required,structural,total= 15.595 in2
(4/3)As,required,structural,total= 20.794 in2
1/2
As,min,1=3(f'c) bwd/fy= 29.059 in2
As,min,2=200bwd/fy= 30.631 in2
As,min,1 or 2, controlling= 30.631 in2
As,min,3=(0.0018 or 0.002)Ag= 21.254 in2
As,required=
21.254 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.414
gs= 0.829 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 18.269 in2
As,required= 21.254 in2
E'=E-Offset = 12 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 9.961 in. OK; sufficient length available to develop hook
Req. number of short bars = 48.11
Prov. number of short bars = 31

Required Flexural Reinforcement - Long Bars


Mu= 45999.50 k-in. Total moment on pile cap with offset
Mu= 3172.38 k-in./ft 1 ft strip design
d= 38.365 in.
As,required,structural,per ft= 1.592 in2/ft
As,required,structural,total= 23.085 in2
(4/3)As,required,structural,total= 30.780 in2
As,min,1=3(f'c)1/2bwd/fy= 21.110 in2
As,min,2=200bwd/fy= 22.252 in2
As,min,1 or 2, controlling= 22.252 in2
As,min,3=(0.0018 or 0.002)Ag= 15.034 in2
As,required= 23.085 in2
cb= 3.64 in.
ld=
36.145 in.
lavailable= 111.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 18.22

93 of 228 09/13/2020 12:25:57


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 16


(continued)

94 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38.000 in.
d/2= 19.000 in.
No. of piles outside d/2 from face of the column = 12
4(fc')0.5= 252.98 psi
b0= 224.00 in.
Vc= 2153.38 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1615.04 kips
Vu= 1271.55 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.787

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38.000 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 126.49 psi
bd= 6612.00 in2
Vc= 836.36 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 627.27 kips
Vu= 295.84 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.472

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38.000 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 126.49 psi
bd= 9348.00 in.
Vc= 1182.44 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 886.83 kips
Vu= 446.40 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.503

(continued)

95 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 38.000 in.

d/2= 19.000 in.


No. of piles outside face of the column = 12
wactual= 30.000 in. > d/2 Limit state not applicable
Vu= 1252.80 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 224.000 in.
bs= 72.000 in.

k= 7.881 based on k=2(d/w)(1+d/c) acting at column face


Vc= 1363.81 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1022.86 kips
Vu/f Vc= 1.225 ****COMBINED**** Vu/f Vc= 1.960

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.365 in.
w'= 30.000 in.
w'/d= 0.782 OK, this limit state should be checked
Vu= 635.76 kips
Mu= 43150.32 k-in.
Vud/Mu= 0.565
Mu/(Vud)= 1.769
k= -2.309
fVc= -731.10 kips
Vu/f Vc= -0.870

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 37.355 in.
w'= 66.000 in.
w'/d= 1.767 Limit state not applicable
Vu= 384.08 kips
Mu= 28803.12 k-in.
Vud/Mu= 0.498
Mu/(Vud)= 2.008
k= -1.676
fVc= -730.64 kips

96 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= -0.526


(continued)

97 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 44.04 CY

Short Steel Bar Summary:


31 Total #6 Bars of length 14.000 ft (per bar)
0 Total Hooks of length 0.785 ft (per bar)
Weight = 652.4 lbs
Long Steel Bar Summary:
16 Total #10 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 1379.3 lbs

Total weight of all steel = 2031.7 lbs or 1.016 tons

Comments:

98 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

99 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

13 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in.
Pile Cap Dcap= 58 in.
Pile Cap Dimension A= 23.284 ft.
Pile Cap Dimension B= 14.5 ft.
Short Bars Size (No.) = 8
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 47.230 in.
Reinf. Effective dlong bars = 48.365 in.
Reinf. Effective dshear checks = 48 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1272.36 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 17.835 in.

100 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 18 in.


(continued)

101 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 28244.29 k-in. Total moment on pile cap with offset
Mu= 1213.03 k-in./ft 1 ft strip design
d= 47.230 in.
As,required,structural,per ft= 0.494 in2/ft
As,required,structural,total= 11.493 in2
(4/3)As,required,structural,total= 15.324 in2
1/2
As,min,1=3(f'c) bwd/fy= 41.731 in2
As,min,2=200bwd/fy= 43.988 in2
As,min,1 or 2, controlling= 43.988 in2
As,min,3=(0.0018 or 0.002)Ag= 29.170 in2
As,required=
29.170 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.606
gs= 0.768 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 14.164 in2
As,required= 29.170 in2
cb= 3.50 in.
ld= 28.460 in.
lavailable= 75.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 37.14
Prov. number of short bars = 29

Required Flexural Reinforcement - Long Bars


Mu= 50077.13 k-in. Total moment on pile cap with offset
Mu= 3453.60 k-in./ft 1 ft strip design
d= 48.365 in.
As,required,structural,per ft= 1.366 in2/ft
As,required,structural,total= 19.803 in2
(4/3)As,required,structural,total= 26.404 in2
As,min,1=3(f'c)1/2bwd/fy= 26.612 in2
As,min,2=200bwd/fy= 28.052 in2
As,min,1 or 2, controlling= 28.052 in2
As,min,3=(0.0018 or 0.002)Ag= 18.166 in2
As,required= 26.404 in2
cb= 3.33 in.
ld= 36.145 in.
lavailable= 127.704 in. OK; sufficient length available to develop bar
Req. number of long bars = 20.84

102 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 26


(continued)

103 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48.000 in.
d/2= 24.000 in.
No. of piles outside d/2 from face of the column = 12
4(fc')0.5= 252.98 psi
b0= 264.00 in.
Vc= 3205.79 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2404.34 kips
Vu= 1179.45 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.491

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 8352.00 in2
Vc= 1056.45 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 792.34 kips
Vu= 524.08 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.661

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48.000 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 126.49 psi
bd= 13411.58 in.
Vc= 1696.45 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1272.33 kips
Vu= 316.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.249

(continued)

104 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 48.000 in.

d/2= 24.000 in.


No. of piles outside face of the column = 12
wactual= 30.000 in. > d/2 Limit state not applicable
Vu= 1146.97 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 264.000 in.
bs= 72.000 in.

k= 11.733 based on k=2(d/w)(1+d/c) acting at column face


Vc= 2564.63 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1923.47 kips
Vu/f Vc= 0.596 ****COMBINED**** Vu/f Vc= 0.858

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.365 in.
w'= 56.352 in.
w'/d= 1.165 Limit state not applicable
Vu= 456.80 kips
Mu= 48035.74 k-in.
Vud/Mu= 0.460
Mu/(Vud)= 2.174
k= -3.233
fVc= -1290.50 kips
Vu/f Vc= -0.354

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.23 in.
w'= 30.000 in.
w'/d= 0.635 OK, this limit state should be checked
Vu= 464.44 kips
Mu= 26177.11 k-in.
Vud/Mu= 0.838
Mu/(Vud)= 1.193
k= 1.613
fVc= 1009.89 kips

105 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= 0.460


(continued)

106 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 60.44 CY

Short Steel Bar Summary: Actual Stres


29 Total #8 Bars of length 14.000 ft (per bar)
0 Total Hooks of length 1.047 ft (per bar)
Weight = 1085.0 lbs
Long Steel Bar Summary:
26 Total #10 Bars of length 22.784 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 2553.4 lbs

Total weight of all steel = 3638.4 lbs or 1.819 tons

Comments: Actual Stres

Actual Stres

Actual Stres

107 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

108 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

14 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Load Factor = 1.6 ###
Pile Type = Steel Bar No.
Pile Shape = Round ###
Concrete Comp. Strength, f'c= 4 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 40 tons ###
Pile Allowable Load (ASD) = 80 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions ###
Pile Spacing, L= 6 provided to the left referencing ###
ft.
figure below.
Pile Edge Distance, E= 15 in. Short hook
Pile Cap Dmin, recommended= 23 in. Long hook a
Pile Cap Dcap= 70 in. Short Bar D
Pile Cap Dimension A= 20.5 ft. Short Bar Ar
Pile Cap Dimension B= 18.892 ft. Steel pile em
Short Bars Size (No.) = 9
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 59.166 in.
Reinf. Effective dlong bars = 60.365 in. If given pile
Reinf. Effective dshear checks = 60 in.
Equivalent P
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? OK d=
CRSI Limit State 1 Adequate? OK d/2=
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK Diameter fo
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK Area in shea
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK 4(fc')0.5=
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA Vc=
CRSI Limit State 6 Adequate? OK
Results: Vu=
Column Size Determination Vu/f Vc=
Net Column Capacity Pu= 1249.80 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 17.676 in.

109 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 18 in.


(continued)

110 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 40686.03 k-in. Total moment on pile cap with offset
Mu= 1984.68 k-in./ft 1 ft strip design
d= 59.166 in.
As,required,structural,per ft= 0.644 in2/ft
As,required,structural,total= 13.204 in2
(4/3)As,required,structural,total= 17.606 in2
1/2
As,min,1=3(f'c) bwd/fy= 46.026 in2
As,min,2=200bwd/fy= 48.516 in2
As,min,1 or 2, controlling= 48.516 in2
As,min,3=(0.0018 or 0.002)Ag= 30.996 in2
As,required=
30.996 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.085 c. to c. spacing o
gs= 0.959 % steel concentrated of width B of long side A concrete cover =
As,required,structural,total,modfied= 13.743 in2 cb=

As,required= 30.996 in2


cb= 3.56 in. yt=

ld= 32.103 in. ye =

lavailable= 101.352 in. OK; sufficient length available to develop bar ys =

Req. number of short bars = 31.02 (cb+Ktr)/db=

Prov. number of short bars = 31 l d=


lavailable=

Required Flexural Reinforcement - Long Bars


Mu= 38668.97 k-in. Total moment on pile cap with offset
Mu= 2046.84 k-in./ft 1 ft strip design
d= 60.365 in. c. to c. spacing o
As,required,structural,per ft= 0.651 in2
/ft concrete cover =
As,required,structural,total= 12.303 in2 cb=

(4/3)As,required,structural,total= 16.404 in2


As,min,1=3(f'c)1/2bwd/fy= 43.276 in2 yt=

As,min,2=200bwd/fy= 45.617 in2 ye =

As,min,1 or 2, controlling= 45.617 in2 ys =

As,min,3=(0.0018 or 0.002)Ag= 28.565 in2 (cb+Ktr)/db=

As,required= 28.565 in2 l d=

cb= 3.64 in. lavailable=

ld= 36.145 in.


lavailable= 111.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 22.55

111 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 24


(continued)

112 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - distance fro
d= 60.000 in. distance fro
d/2= 30.000 in. distance fro
No. of piles outside d/2 from face of the column = 14 distance fro
4(fc')0.5= 252.98 psi distance fro
b0= 312.00 in. distance fro
0.5
Vc= 4735.83 kips based on Vc=4(fc') b0d acting at d/2 from column face
fVc= 3551.87 kips Limit State A
Vu= 1308.95 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.369

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - distance fro
d= 60.000 in. distance fro
No. of piles outside d from face of the column = 4 distance fro
2(fc')0.5= 126.49 psi distance fro
bd= 13602.24 in2 Limit State A
Vc= 1720.56 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1290.42 kips
Vu= 392.98 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.305

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 - distance fro
d= 60.000 in. distance fro
No. of piles outside d from face of the column = 3 distance fro
2(fc')0.5= 126.49 psi Limit State A
bd= 14760.00 in.
Vc= 1867.01 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1400.26 kips
Vu= 277.92 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.198

(continued)

113 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 60.000 in.
d/2= 30.000 in.
No. of piles outside face of the column = 14
wactual= 30.000 in. < d/2 This procedure applies
Vu= 1252.95 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 312.000 in. Limit State A
bs= 72.000 in.
k= 17.333 based on k=2(d/w)(1+d/c) acting at column face
Vc= 4735.83 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 3551.87 kips
Vu/f Vc= 0.353

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 60.365 in.
w'= 30.000 in.
w'/d= 0.497 OK, this limit state should be checked
Vu= 516.74 kips
Mu= 36365.97 k-in. Limit State A
Vud/Mu= 0.858
Mu/(Vud)= 1.166
k= 2.339
fVc= 1518.35 kips
Vu/f Vc= 0.340

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 59.166 in.
w'= 30.000 in.
w'/d= 0.507 OK, this limit state should be checked
Vu= 646.42 kips
Mu= 38105.46 k-in. Limit State A
Vud/Mu= 1.004
Mu/(Vud)= 0.996
k= 3.981
fVc= 2748.79 kips
Vu/f Vc= 0.235

114 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

(continued)

115 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars d=


Concrete Summary: d/2=
Quantity = 83.67 CY Diameter fo
Area in shea
Short Steel Bar Summary: 4(fc')0.5=
31 Total #9 Bars of length 18.392 ft (per bar) Vc=
0 Total Hooks of length 1.383 ft (per bar)
Weight = 1938.7 lbs Vu=
Long Steel Bar Summary:
24 Total #10 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 2069.0 lbs d=
d/2=
Total weight of all steel = 4007.7 lbs or 2.004 tons Straight dim
Round dime
Area in shea
Comments: 4(fc')0.5=
Vc=

Vu=

d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=

Vu=
Vu/f Vc=

d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=

116 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

117 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

15 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in. A'= 11.063 ft.
Pile Cap Dcap= 48 in. B'= 13.444 ft.
Pile Cap Dimension A= 23.284 ft.
Pile Cap Dimension B= 20.5 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 36.885 in.
Reinf. Effective dlong bars = 38.295 in.
Reinf. Effective dshear checks = 38 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1503.16 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 19.385 in.

118 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 20 in.


(continued)

119 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 52005.24 k-in. Total moment on pile cap with offset
Mu= 2233.52 k-in./ft 1 ft strip design
d= 36.885 in.
As,required,structural,per ft= 1.160 in2/ft
As,required,structural,total= 27.002 in2
(4/3)As,required,structural,total= 36.003 in2
1/2
As,min,1=3(f'c) bwd/fy= 32.590 in2
As,min,2=200bwd/fy= 34.353 in2
As,min,1 or 2, controlling= 34.353 in2
As,min,3=(0.0018 or 0.002)Ag= 24.141 in2
As,required=
34.353 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.136
gs= 0.936 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 28.719 in2
As,required= 34.353 in2
cb= 3.71 in.
ld= 40.129 in.
lavailable= 110.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 22.00
Prov. number of short bars = 17

Required Flexural Reinforcement - Long Bars


Mu= 49818.82 k-in. Total moment on pile cap with offset
Mu= 2430.19 k-in./ft 1 ft strip design
d= 38.295 in.
As,required,structural,per ft= 1.216 in2/ft
As,required,structural,total= 24.918 in2
(4/3)As,required,structural,total= 33.224 in2
As,min,1=3(f'c)1/2bwd/fy= 29.790 in2
As,min,2=200bwd/fy= 31.402 in2
As,min,1 or 2, controlling= 31.402 in2
As,min,3=(0.0018 or 0.002)Ag= 21.254 in2
As,required= 31.402 in2
cb= 3.71 in.
ld= 40.129 in.
lavailable= 126.704 in. OK; sufficient length available to develop bar
Req. number of long bars = 20.11

120 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 22


(continued)

121 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38.000 in.
d/2= 19.000 in.
No. of piles outside d/2 from face of the column = 14
4(fc')0.5= 252.98 psi
b0= 232.00 in.
Vc= 2230.29 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1672.72 kips
Vu= 1397.59 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.836

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38.000 in.
No. of piles outside d from face of the column = 6
2(fc')0.5= 126.49 psi
bd= 9348.00 in2
Vc= 1182.44 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 886.83 kips
Vu= 638.30 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.720

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 10617.50 in.
Vc= 1343.02 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1007.26 kips
Vu= 520.99 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.517

(continued)

122 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 38.000 in.

d/2= 19.000 in.


No. of piles outside face of the column = 14
wactual= 29.000 in. > d/2 Limit state not applicable
Vu= 1377.83 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 232.000 in.
bs= 80.000 in.

k= 7.600 based on k=2(d/w)(1+d/c) acting at column face


Vc= 1461.23 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1095.92 kips
Vu/f Vc= 1.257 ****COMBINED**** Vu/f Vc= 1.828

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.295 in.
w'= 55.352 in.
w'/d= 1.445 Limit state not applicable
Vu= 575.98 kips
Mu= 47062.89 k-in.
Vud/Mu= 0.469
Mu/(Vud)= 2.134
k= -2.471
fVc= -1103.97 kips
Vu/f Vc= -0.522

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 36.885 in.
w'= 29.000 in.
w'/d= 0.786 OK, this limit state should be checked
Vu= 706.21 kips
Mu= 48600.96 k-in.
Vud/Mu= 0.536
Mu/(Vud)= 1.866
k= -2.893
fVc= -1414.47 kips

123 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= -0.499


(continued)

124 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 64.33 CY

Short Steel Bar Summary:


17 Total #11 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1806.5 lbs
Long Steel Bar Summary:
22 Total #11 Bars of length 22.784 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2663.2 lbs

Total weight of all steel = 4469.6 lbs or 2.235 tons

Comments:

125 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

126 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

16 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Load Factor = 1.6 ###
Pile Type = Steel Bar No.
Pile Shape = Round ###
Concrete Comp. Strength, f'c= 4 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 40 tons ###
Pile Allowable Load (ASD) = 80 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions ###
Pile Spacing, L= 6 provided to the left referencing ###
ft.
figure below.
Pile Edge Distance, E= 15 in. Short hook
Pile Cap Dmin, recommended= 23 in. Long hook a
Pile Cap Dcap= 71 in. Short Bar D
Pile Cap Dimension A= 20.5 ft. Short Bar Ar
Pile Cap Dimension B= 20.5 ft. Steel pile em
Short Bars Size (No.) = 9
Long Bars Size (No.) = 9
Reinf. Effective dshort bars = 60.308 in.
Reinf. Effective dlong bars = 61.436 in. If given pile
Reinf. Effective dshear checks = 61 in.
Equivalent P
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? OK d=
CRSI Limit State 1 Adequate? OK d/2=
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK Diameter fo
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK Area in shea
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK 4(fc')0.5=
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK Vc=
CRSI Limit State 6 Adequate? OK
Results: Vu=
Column Size Determination Vu/f Vc=
Net Column Capacity Pu= 1451.25 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 19.048 in.

127 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 20 in.


(continued)

128 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 54791.35 k-in. Total moment on pile cap with offset
Mu= 2672.75 k-in./ft 1 ft strip design
d= 60.308 in.
As,required,structural,per ft= 0.848 in2/ft
As,required,structural,total= 17.378 in2
(4/3)As,required,structural,total= 23.170 in2
1/2
As,min,1=3(f'c) bwd/fy= 46.915 in2
As,min,2=200bwd/fy= 49.453 in2
As,min,1 or 2, controlling= 49.453 in2
As,min,3=(0.0018 or 0.002)Ag= 31.439 in2
As,required=
31.439 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000 c. to c. spacing o
gs= 1.000 % steel concentrated of width B of long side A concrete cover =
As,required,structural,total,modfied= 17.378 in2 cb=

As,required= 31.439 in2


cb= 3.56 in. yt=

ld= 32.103 in. ye =

lavailable= 110.000 in. OK; sufficient length available to develop bar ys =

Req. number of short bars = 31.46 (cb+Ktr)/db=

Prov. number of short bars = 30 l d=


lavailable=

Required Flexural Reinforcement - Long Bars


Mu= 54791.35 k-in. Total moment on pile cap with offset
Mu= 2672.75 k-in./ft 1 ft strip design
d= 61.436 in. c. to c. spacing o
As,required,structural,per ft= 0.832 in2
/ft concrete cover =
As,required,structural,total= 17.066 in2 cb=

(4/3)As,required,structural,total= 22.754 in2


As,min,1=3(f'c)1/2bwd/fy= 47.792 in2 yt=

As,min,2=200bwd/fy= 50.378 in2 ye =

As,min,1 or 2, controlling= 50.378 in2 ys =

As,min,3=(0.0018 or 0.002)Ag= 31.439 in2 (cb+Ktr)/db=

As,required= 31.439 in2 l d=

cb= 3.56 in. lavailable=

ld= 32.103 in.


lavailable= 110.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 31.46

129 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 30


(continued)

130 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - distance fro
d= 61.000 in. distance fro
d/2= 30.500 in. distance fro
No. of piles outside d/2 from face of the column = 12 distance fro
4(fc')0.5= 252.98 psi distance fro
b0= 324.00 in. Limit State A
0.5
Vc= 4999.94 kips based on Vc=4(fc') b0d acting at d/2 from column face
fVc= 3749.96 kips
Vu= 1003.94 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.268

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - distance fro
d= 61.000 in. distance fro
No. of piles outside d from face of the column = 4 distance fro
2(fc')0.5= 126.49 psi Limit State A
bd= 15006.00 in2

Vc= 1898.13 kips based on Vc=2(fc')0.5bd acting at d from column face


fVc= 1423.59 kips
Vu= 385.86 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.271

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 - distance fro
d= 61.000 in. distance fro
No. of piles outside d from face of the column = 4 distance fro
2(fc')0.5= 126.49 psi Limit State A
bd= 15006.00 in.
Vc= 1898.13 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1423.59 kips
Vu= 385.86 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.271

(continued)

131 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 61.000 in.
d/2= 30.500 in.
No. of piles outside face of the column = 16
wactual= 29.000 in. < d/2 This procedure applies
Vu= 1455.19 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 324.000 in. Limit State A
bs= 80.000 in.
k= 17.038 based on k=2(d/w)(1+d/c) acting at column face
Vc= 5258.56 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 3943.92 kips
Vu/f Vc= 0.369

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 61.436 in.
w'= 29.000 in.
w'/d= 0.472 OK, this limit state should be checked
Vu= 749.88 kips
Mu= 51072.27 k-in. Limit State A
Vud/Mu= 0.902
Mu/(Vud)= 1.109
k= 3.072
fVc= 2202.02 kips
Vu/f Vc= 0.341

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 60.308 in.
w'= 29.000 in.
w'/d= 0.481 OK, this limit state should be checked
Vu= 749.88 kips
Mu= 51072.27 k-in. Limit State A
Vud/Mu= 0.885
Mu/(Vud)= 1.129
k= 2.798
fVc= 1969.28 kips
Vu/f Vc= 0.381

132 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

(continued)

133 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars d=


Concrete Summary: d/2=
Quantity = 92.09 CY Diameter fo
Area in shea
Short Steel Bar Summary: 4(fc')0.5=
30 Total #9 Bars of length 20.000 ft (per bar) Vc=
0 Total Hooks of length 1.383 ft (per bar)
Weight = 2040.2 lbs Vu=
Long Steel Bar Summary:
30 Total #9 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.383 ft (per bar)
Weight = 2040.2 lbs d=
d/2=
Total weight of all steel = 4080.5 lbs or 2.040 tons Straight dim
Round dime
Area in shea
Comments: 4(fc')0.5=
Vc=

Vu=

d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=

Vu=
Vu/f Vc=

d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=

134 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

135 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

17 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in. Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 shown above. Actual dimensions
in.
provided to the left referencing
Pile Spacing, L= 6 ft. figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in. A'= 11.063 ft.
Pile Cap Dcap= 51 in. B'= 13.444 ft.
Pile Cap Dimension A= 23.284 ft.
Pile Cap Dimension B= 20.5 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 39.955 in.
Reinf. Effective dlong bars = 41.295 in.
Reinf. Effective dshear checks = 41 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1733.11 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 20.815 in.

136 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 21 in.


(continued)

137 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 51169.89 k-in. Total moment on pile cap with offset
Mu= 2197.64 k-in./ft 1 ft strip design
d= 39.955 in.
As,required,structural,per ft= 1.051 in2/ft
As,required,structural,total= 24.478 in2
(4/3)As,required,structural,total= 32.637 in2
1/2
As,min,1=3(f'c) bwd/fy= 35.303 in2
As,min,2=200bwd/fy= 37.212 in2
As,min,1 or 2, controlling= 37.212 in2
As,min,3=(0.0018 or 0.002)Ag= 25.650 in2
As,required=
32.637 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.136
gs= 0.936 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 26.034 in2
As,required= 32.637 in2
cb= 3.64 in.
ld= 36.145 in.
lavailable= 109.500 in. OK; sufficient length available to develop bar
Req. number of short bars = 25.76
Prov. number of short bars = 16

Required Flexural Reinforcement - Long Bars


Mu= 64578.70 k-in. Total moment on pile cap with offset
Mu= 3150.18 k-in./ft 1 ft strip design
d= 41.295 in.
As,required,structural,per ft= 1.464 in2/ft
As,required,structural,total= 30.008 in2
(4/3)As,required,structural,total= 40.011 in2
As,min,1=3(f'c)1/2bwd/fy= 32.124 in2
As,min,2=200bwd/fy= 33.862 in2
As,min,1 or 2, controlling= 33.862 in2
As,min,3=(0.0018 or 0.002)Ag= 22.583 in2
As,required= 33.862 in2
cb= 3.71 in.
ld= 40.129 in.
lavailable= 126.204 in. OK; sufficient length available to develop bar
Req. number of long bars = 21.69

138 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 15


(continued)

139 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 41.000 in.
d/2= 20.500 in.
No. of piles outside d/2 from face of the column = 16
4(fc')0.5= 252.98 psi
b0= 248.00 in.
Vc= 2572.32 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1929.24 kips
Vu= 1632.34 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.846

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 41.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 10086.00 in2
Vc= 1275.79 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 956.84 kips
Vu= 764.29 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.799

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 41.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 11455.73 in.
Vc= 1449.05 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1086.79 kips
Vu= 520.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.479

(continued)

140 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 41.000 in.

d/2= 20.500 in.


No. of piles outside face of the column = 16
wactual= 28.500 in. > d/2 Limit state not applicable
Vu= 1608.23 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 248.000 in.
bs= 84.000 in.

k= 8.495 based on k=2(d/w)(1+d/c) acting at column face


Vc= 1850.27 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1387.70 kips
Vu/f Vc= 1.159 ****COMBINED**** Vu/f Vc= 1.695

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 41.295 in.
w'= 54.852 in.
w'/d= 1.328 Limit state not applicable
Vu= 692.85 kips
Mu= 61080.69 k-in.
Vud/Mu= 0.468
Mu/(Vud)= 2.135
k= -2.693
fVc= -1297.47 kips
Vu/f Vc= -0.534

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 39.955 in.
w'= 28.500 in.
w'/d= 0.713 OK, this limit state should be checked
Vu= 801.35 kips
Mu= 53523.75 k-in.
Vud/Mu= 0.598
Mu/(Vud)= 1.672
k= -1.866
fVc= -988.22 kips

141 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= -0.811


(continued)

142 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 68.35 CY

Short Steel Bar Summary: ###


16 Total #10 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 1379.3 lbs
Long Steel Bar Summary:
15 Total #11 Bars of length 22.784 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1815.8 lbs

Total weight of all steel = 3195.1 lbs or 1.598 tons

Comments: ###

###

###

143 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

144 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

18 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in.
Pile Cap Dcap= 58 in.
Pile Cap Dimension A= 23.284 ft.
Pile Cap Dimension B= 20.5 ft.
Short Bars Size (No.) = 9
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 47.166 in.
Reinf. Effective dlong bars = 48.365 in.
Reinf. Effective dshear checks = 48 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1750.31 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 20.918 in.

145 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 21 in.


(continued)

146 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 55820.35 k-in. Total moment on pile cap with offset
Mu= 2397.37 k-in./ft 1 ft strip design
d= 47.166 in.
As,required,structural,per ft= 0.970 in2/ft
As,required,structural,total= 22.594 in2
(4/3)As,required,structural,total= 30.125 in2
1/2
As,min,1=3(f'c) bwd/fy= 41.674 in2
As,min,2=200bwd/fy= 43.929 in2
As,min,1 or 2, controlling= 43.929 in2
As,min,3=(0.0018 or 0.002)Ag= 29.170 in2
As,required=
30.125 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.136
gs= 0.936 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 24.031 in2
As,required= 30.125 in2
cb= 3.56 in.
ld= 32.103 in.
lavailable= 109.500 in. OK; sufficient length available to develop bar
Req. number of short bars = 30.15
Prov. number of short bars = 18

Required Flexural Reinforcement - Long Bars


Mu= 67863.45 k-in. Total moment on pile cap with offset
Mu= 3310.41 k-in./ft 1 ft strip design
d= 48.365 in.
As,required,structural,per ft= 1.309 in2/ft
As,required,structural,total= 26.825 in2
(4/3)As,required,structural,total= 35.766 in2
As,min,1=3(f'c)1/2bwd/fy= 37.624 in2
As,min,2=200bwd/fy= 39.659 in2
As,min,1 or 2, controlling= 39.659 in2
As,min,3=(0.0018 or 0.002)Ag= 25.682 in2
As,required= 35.766 in2
cb= 3.64 in.
ld= 36.145 in.
lavailable= 126.204 in. OK; sufficient length available to develop bar
Req. number of long bars = 28.24

147 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 15


(continued)

148 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48.000 in.
d/2= 24.000 in.
No. of piles outside d/2 from face of the column = 18
4(fc')0.5= 252.98 psi
b0= 276.00 in.
Vc= 3351.51 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2513.63 kips
Vu= 1788.66 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.712

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 11808.00 in2
Vc= 1493.61 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1120.21 kips
Vu= 735.08 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.656

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 13411.58 in.
Vc= 1696.45 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1272.33 kips
Vu= 494.82 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.389

(continued)

149 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 48.000 in.

d/2= 24.000 in.


No. of piles outside face of the column = 18
wactual= 28.500 in. > d/2 Limit state not applicable
Vu= 1753.86 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 276.000 in.
bs= 84.000 in.

k= 11.068 based on k=2(d/w)(1+d/c) acting at column face


Vc= 2822.32 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 2116.74 kips
Vu/f Vc= 0.829 ****COMBINED**** Vu/f Vc= 1.212

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.365 in.
w'= 54.852 in.
w'/d= 1.134 Limit state not applicable
Vu= 639.96 kips
Mu= 64530.97 k-in.
Vud/Mu= 0.480
Mu/(Vud)= 2.085
k= -2.941
fVc= -1659.74 kips
Vu/f Vc= -0.386

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.166 in.
w'= 28.500 in.
w'/d= 0.604 OK, this limit state should be checked
Vu= 770.79 kips
Mu= 51804.74 k-in.
Vud/Mu= 0.702
Mu/(Vud)= 1.425
k= -0.204
fVc= -127.25 kips

150 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= -6.057


(continued)

151 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 85.45 CY

Short Steel Bar Summary:


18 Total #9 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.383 ft (per bar)
Weight = 1224.1 lbs
Long Steel Bar Summary:
15 Total #10 Bars of length 22.784 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 1473.1 lbs

Total weight of all steel = 2697.3 lbs or 1.349 tons

Comments:

152 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

153 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

19 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in.
Pile Cap Dcap= 54 in.
Pile Cap Dimension A= 24.892 ft.
Pile Cap Dimension B= 20.5 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 42.955 in.
Reinf. Effective dlong bars = 44.295 in.
Reinf. Effective dshear checks = 44 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1880.89 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.685 in.

154 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 22 in.


(continued)

155 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 64599.07 k-in. Total moment on pile cap with offset
Mu= 2595.17 k-in./ft 1 ft strip design
d= 42.955 in.
As,required,structural,per ft= 1.155 in2/ft
As,required,structural,total= 28.749 in2
(4/3)As,required,structural,total= 38.332 in2
1/2
As,min,1=3(f'c) bwd/fy= 40.575 in2
As,min,2=200bwd/fy= 42.769 in2
As,min,1 or 2, controlling= 42.769 in2
As,min,3=(0.0018 or 0.002)Ag= 29.034 in2
As,required=
38.332 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.214
gs= 0.903 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 31.530 in2
As,required= 38.332 in2
cb= 3.64 in.
ld= 36.145 in.
lavailable= 109.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 30.26
Prov. number of short bars = 17

Required Flexural Reinforcement - Long Bars


Mu= 79062.79 k-in. Total moment on pile cap with offset
Mu= 3856.72 k-in./ft 1 ft strip design
d= 44.295 in.
As,required,structural,per ft= 1.673 in2/ft
As,required,structural,total= 34.293 in2
(4/3)As,required,structural,total= 45.724 in2
As,min,1=3(f'c)1/2bwd/fy= 34.458 in2
As,min,2=200bwd/fy= 36.322 in2
As,min,1 or 2, controlling= 36.322 in2
As,min,3=(0.0018 or 0.002)Ag= 23.911 in2
As,required= 36.322 in2
cb= 3.71 in.
ld= 40.129 in.
lavailable= 135.352 in. OK; sufficient length available to develop bar
Req. number of long bars = 23.26

156 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 13


(continued)

157 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 44.000 in.
d/2= 22.000 in.
No. of piles outside d/2 from face of the column = 18
4(fc')0.5= 252.98 psi
b0= 264.00 in.
Vc= 2938.64 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2203.98 kips
Vu= 1785.56 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.810

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 44.000 in.
No. of piles outside d from face of the column = 8
2(fc')0.5= 126.49 psi
bd= 10824.00 in2
Vc= 1369.14 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1026.85 kips
Vu= 849.92 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.828

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 44.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 13142.98 in.
Vc= 1662.47 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1246.85 kips
Vu= 487.66 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.391

(continued)

158 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 44.000 in.

d/2= 22.000 in.


No. of piles outside face of the column = 18
wactual= 28.000 in. > d/2 Limit state not applicable
Vu= 1756.52 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 264.000 in.
bs= 88.000 in.

k= 9.429 based on k=2(d/w)(1+d/c) acting at column face


Vc= 2308.93 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1731.70 kips
Vu/f Vc= 1.014 ****COMBINED**** Vu/f Vc= 1.492

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 44.295 in.
w'= 54.352 in.
w'/d= 1.227 Limit state not applicable
Vu= 768.74 kips
Mu= 74862.62 k-in.
Vud/Mu= 0.455
Mu/(Vud)= 2.199
k= -3.165
fVc= -1635.97 kips
Vu/f Vc= -0.470

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 42.955 in.
w'= 28.000 in.
w'/d= 0.652 OK, this limit state should be checked
Vu= 901.09 kips
Mu= 59676.96 k-in.
Vud/Mu= 0.649
Mu/(Vud)= 1.542
k= -1.069
fVc= -650.31 kips

159 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= -1.386


(continued)

160 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 85.05 CY

Short Steel Bar Summary:


17 Total #10 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 1465.5 lbs
Long Steel Bar Summary:
13 Total #11 Bars of length 24.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1684.8 lbs

Total weight of all steel = 3150.3 lbs or 1.575 tons

Comments:

161 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

162 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

20 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 55 in.
Pile Cap Dcap= 69 in.
Pile Cap Dimension A= 26.5 ft.
Pile Cap Dimension B= 20.5 ft.
Short Bars Size (No.) = 9
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 58.026 in.
Reinf. Effective dlong bars = 59.295 in.
Reinf. Effective dshear checks = 59 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1810.32 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.274 in.

163 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 22 in.


(continued)

164 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 67922.73 k-in. Total moment on pile cap with offset
Mu= 2563.12 k-in./ft 1 ft strip design
d= 58.026 in.
As,required,structural,per ft= 0.845 in2/ft
As,required,structural,total= 22.382 in2
(4/3)As,required,structural,total= 29.842 in2
1/2
As,min,1=3(f'c) bwd/fy= 58.351 in2
As,min,2=200bwd/fy= 61.508 in2
As,min,1 or 2, controlling= 61.508 in2
As,min,3=(0.0018 or 0.002)Ag= 39.496 in2
As,required=
39.496 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.293
gs= 0.872 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 25.239 in2
As,required= 39.496 in2
cb= 3.56 in.
ld= 32.103 in.
lavailable= 109.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 39.52
Prov. number of short bars = 36

Required Flexural Reinforcement - Long Bars


Mu= 80258.00 k-in. Total moment on pile cap with offset
Mu= 3915.02 k-in./ft 1 ft strip design
d= 59.295 in.
As,required,structural,per ft= 1.261 in2/ft
As,required,structural,total= 25.842 in2
(4/3)As,required,structural,total= 34.456 in2
As,min,1=3(f'c)1/2bwd/fy= 46.127 in2
As,min,2=200bwd/fy= 48.622 in2
As,min,1 or 2, controlling= 48.622 in2
As,min,3=(0.0018 or 0.002)Ag= 30.553 in2
As,required= 34.456 in2
cb= 3.71 in.
ld= 40.129 in.
lavailable= 145.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 22.07

165 of 228 09/13/2020 12:25:58


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 24


(continued)

166 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 59.000 in.
d/2= 29.500 in.
No. of piles outside d/2 from face of the column = 18
4(fc')0.5= 252.98 psi
b0= 324.00 in.
Vc= 4836.01 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3627.01 kips
Vu= 1617.19 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.446

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 59.000 in.
No. of piles outside d from face of the column = 8
2(fc')0.5= 126.49 psi
bd= 14514.00 in2
Vc= 1835.89 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1376.92 kips
Vu= 814.18 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.591

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 59.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 18762.00 in.
Vc= 2373.23 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1779.92 kips
Vu= 478.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.269

(continued)

167 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 59.000 in.

d/2= 29.500 in.


No. of piles outside face of the column = 20
wactual= 28.000 in. < d/2 This procedure applies
Vu= 1814.95 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 324.000 in.
bs= 88.000 in.

k= 15.516 based on k=2(d/w)(1+d/c) acting at column face


Vc= 5095.08 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 3821.31 kips
Vu/f Vc= 0.475 ****COMBINED**** Vu/f Vc= 0.780

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 59.295 in.
w'= 64.000 in.
w'/d= 1.079 Limit state not applicable
Vu= 675.09 kips
Mu= 76580.66 k-in.
Vud/Mu= 0.523
Mu/(Vud)= 1.913
k= -2.320
fVc= -1605.35 kips
Vu/f Vc= -0.421

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 58.026 in.
w'= 28.000 in.
w'/d= 0.483 OK, this limit state should be checked
Vu= 938.68 kips
Mu= 62806.08 k-in.
Vud/Mu= 0.867
Mu/(Vud)= 1.153
k= 2.541
fVc= 2224.49 kips

168 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= 0.422


(continued)

169 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 115.69 CY

Short Steel Bar Summary:


36 Total #9 Bars of length 20.000 ft (per bar)
0 Total Hooks of length 1.383 ft (per bar)
Weight = 2448.3 lbs
Long Steel Bar Summary:
24 Total #11 Bars of length 26.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 3315.4 lbs

Total weight of all steel = 5763.7 lbs or 2.882 tons

Comments:

170 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

171 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

21 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in. A'= 6.338 ft.
Pile Cap Dcap= 60 in. B'= 19.918 ft.
Pile Cap Dimension A= 24.892 ft.
Pile Cap Dimension B= 24.892 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 48.885 in.
Reinf. Effective dlong bars = 50.295 in.
Reinf. Effective dshear checks = 50 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1999.84 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 22.360 in.
Rounded Dimension c= 23 in.

172 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

173 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 76402.01 k-in. Total moment on pile cap with offset
Mu= 3069.34 k-in./ft 1 ft strip design
d= 48.885 in.
As,required,structural,per ft= 1.199 in2/ft
As,required,structural,total= 29.856 in2
(4/3)As,required,structural,total= 39.808 in2
As,min,1=3(f'c)1/2bwd/fy= 46.176 in2
As,min,2=200bwd/fy= 48.674 in2
As,min,1 or 2, controlling= 48.674 in2
As,min,3=(0.0018 or 0.002)Ag= 32.260 in2
As,required=
39.808 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
g s= 1.000 % steel concentrated of width B of long side A
As,required,structural,total,modfied = 29.856 in2
As,required= 39.808 in2
c b= 3.71 in.
l d= 40.129 in.
lavailable= 134.852 in. OK; sufficient length available to develop bar
Req. number of short bars = 25.50
Prov. number of short bars = 17

Required Flexural Reinforcement - Long Bars


Mu= 79926.27 k-in. Total moment on pile cap with offset
Mu= 3210.92 k-in./ft 1 ft strip design
d= 50.295 in.
As,required,structural,per ft= 1.219 in2/ft
As,required,structural,total= 30.355 in2
(4/3)As,required,structural,total= 40.474 in2
As,min,1=3(f'c)1/2bwd/fy= 47.508 in2
As,min,2=200bwd/fy= 50.078 in2
As,min,1 or 2, controlling= 50.078 in2
As,min,3=(0.0018 or 0.002)Ag= 32.260 in2
As,required= 40.474 in2
c b= 3.71 in.
l d= 40.129 in.
lavailable= 134.852 in. OK; sufficient length available to develop bar
Req. number of long bars = 25.92
Prov. number of long bars = 17

174 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

175 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 50.000 in.
d/2= 25.000 in.
No. of piles outside d/2 from face of the column = 20
4(fc')0.5= 252.98 psi
b0= 292.00 in.
V c= 3693.54 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2770.16 kips
Vu= 1916.25 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.692

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 50.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 14305.96 in2
V c= 1809.58 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1357.18 kips
Vu= 705.01 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.519

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 50.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 14935.20 in.
V c= 1889.17 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1416.88 kips
Vu= 705.01 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.498

(continued)

176 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 50.000 in.
d/2= 25.000 in.
No. of piles outside face of the column = 20
wactual= 27.500 in. > d/2 Limit state not applicable
Vu= 1876.25 kips
0.5
4(fc') = 252.98 psi
32(fc')0.5= 2023.86 psi
b0= 292.000 in.
bs= 92.000 in.
k= 11.542 based on k=2(d/w)(1+d/c) acting at column face
V c= 3357.76 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 2518.32 kips
Vu/f Vc= 0.745

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 50.295 in.
w'= 27.500 in.
w'/d= 0.547 OK, this limit state should be checked
Vu= 836.55 kips
M u= 75316.49 k-in.
Vud/Mu= 0.559
Mu/(Vud)= 1.790
k= -3.489
fVc= -2485.98 kips
Vu/f Vc= -0.337 **CONTROLLING** Vu/f Vc= -0.337

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 48.885 in.
w'= 27.500 in.
w'/d= 0.563 OK, this limit state should be checked
Vu= 836.55 kips
M u= 71792.22 k-in.
Vud/Mu= 0.570
Mu/(Vud)= 1.756
k= -3.092
fVc= -2141.76 kips
Vu/f Vc= -0.391 **CONTROLLING** Vu/f Vc= -0.391

177 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

178 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 106.20 CY

Short Steel Bar Summary:


17 Total #11 Bars of length 24.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2203.2 lbs
Long Steel Bar Summary:
17 Total #11 Bars of length 24.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2203.2 lbs

Total weight of all steel = 4406.3 lbs or 2.203 tons

Comments:

179 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

22 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in. Note: Minimum cap dimensions
Minimum Pile Dimension dp= shown above. Actual dimensions
20 in. provided to the left referencing
Pile Spacing, L= 6 ft. figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in. A'= 19.443 ft.
Pile Cap Dcap= 62 in. B'= 11.062 ft.
Pile Cap Dimension A= 26.5 ft.
Pile Cap Dimension B= 23.284 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 50.885 in.
Reinf. Effective dlong bars = 52.295 in.
Reinf. Effective dshear checks = 52 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2104.36 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 22.937 in.
Rounded Dimension c= 23 in.
(continued)

180 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 79099.45 k-in. Total moment on pile cap with offset
Mu= 2984.89 k-in./ft 1 ft strip design
d= 50.885 in.
As,required,structural,per ft= 1.120 in2/ft
As,required,structural,total= 29.680 in2
(4/3)As,required,structural,total= 39.574 in2
As,min,1=3(f'c)1/2bwd/fy= 51.170 in2
As,min,2=200bwd/fy= 53.938 in2
As,min,1 or 2, controlling= 53.938 in2
As,min,3=(0.0018 or 0.002)Ag= 35.489 in2
As,required=
39.574 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.138
g s= 0.935 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 31.598 in2
As,required= 39.574 in2
cb = 3.71 in.
ld= 40.129 in.
lavailable= 125.204 in. OK; sufficient length available to develop bar
Req. number of short bars = 25.35
Prov. number of short bars = 18

Required Flexural Reinforcement - Long Bars


Mu= 82692.42 k-in. Total moment on pile cap with offset
Mu= 3551.47 k-in./ft 1 ft strip design
d= 52.295 in.
As,required,structural,per ft= 1.297 in2/ft
As,required,structural,total= 30.209 in2
(4/3)As,required,structural,total= 40.279 in2
1/2
As,min,1=3(f'c) bwd/fy= 46.206 in2
As,min,2=200bwd/fy= 48.705 in2
As,min,1 or 2, controlling= 48.705 in2
As,min,3=(0.0018 or 0.002)Ag= 31.182 in2
As,required= 40.279 in2
cb = 3.71 in.
ld= 40.129 in.
lavailable= 144.500 in. OK; sufficient length available to develop bar
Req. number of long bars = 25.80
Prov. number of long bars = 17

181 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

182 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 52.000 in.
d/2= 26.000 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 252.98 psi
b 0= 300.00 in.
Vc= 3946.52 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
f Vc= 2959.89 kips
Vu= 2152.80 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.727

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 52.000 in.
No. of piles outside d from face of the column = 7
2(fc')0.5= 126.49 psi
bd= 14529.22 in2
Vc= 1837.82 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1378.36 kips
Vu= 692.96 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.503

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 52.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 16536.00 in.
Vc= 2091.66 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1568.74 kips
Vu= 970.06 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.618

(continued)

183 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 52.000 in.

d/2= 26.000 in.


No. of piles outside face of the column = 22
wactual= 27.500 in. > d/2 Limit state not applicable
Vu= 2108.92 kips
4(fc')0.5= 252.98 psi
0.5
32(fc') = 2023.86 psi
b 0= 300.000 in.
b s= 92.000 in.
k= 12.332 based on k=2(d/w)(1+d/c) acting at column face
Vc= 3731.26 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 2798.44 kips
Vu/f Vc= 0.754 ****COMBINED**** Vu/f Vc= 1.115

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 52.295 in.
w'= 27.500 in.
w'/d= 0.526 OK, this limit state should be checked
Vu= 951.85 kips
Mu= 77412.80 k-in.
Vud/Mu= 0.643
Mu/(Vud)= 1.555
k= -1.449
fVc= -1004.48 kips
Vu/f Vc= -0.948 **CONTROLLING** Vu/f Vc= -0.948

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 50.885 in.
w'= 53.852 in.
w'/d= 1.058 Limit state not applicable
Vu= 827.67 kips
Mu= 74539.35 k-in.
Vud/Mu= 0.565
Mu/(Vud)= 1.770
k= -1.709
fVc= -1312.05 kips
Vu/f Vc= -0.631 **CONTROLLING** Vu/f Vc= -0.631

184 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

185 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 109.82 CY

Short Steel Bar Summary:


18 Total #11 Bars of length 22.784 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2179.0 lbs
Long Steel Bar Summary:
17 Total #11 Bars of length 26.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2348.4 lbs

Total weight of all steel = 4527.4 lbs or 2.264 tons

Comments:

186 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

23 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in. A'= 19.443 ft.
Pile Cap Dcap= 58 in. B'= 12.670 ft.
Pile Cap Dimension A= 26.5 ft.
Pile Cap Dimension B= 24.892 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 46.885 in.
Reinf. Effective dlong bars = 48.295 in.
Reinf. Effective dshear checks = 48 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2228.84 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 23.605 in.
Rounded Dimension c= 24 in.

188 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

189 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 88215.46 k-in. Total moment on pile cap with offset
Mu= 3328.89 k-in./ft 1 ft strip design
d= 46.885 in.
As,required,structural,per ft= 1.358 in2/ft
As,required,structural,total= 35.996 in2
(4/3)As,required,structural,total= 47.994 in2
As,min,1=3(f'c)1/2bwd/fy= 47.148 in2
As,min,2=200bwd/fy= 49.698 in2
As,min,1 or 2, controlling= 49.698 in2
As,min,3=(0.0018 or 0.002)Ag= 33.199 in2
As,required=
47.994 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.065
gs= 0.969 % steel concentrated of width B of long side A
As,required,structural,total,modfied = 37.122 in2
As,required= 47.994 in2
c b= 3.71 in.
l d= 40.129 in.
lavailable= 134.352 in. OK; sufficient length available to develop bar
Req. number of short bars = 30.74
Prov. number of short bars = 17

Required Flexural Reinforcement - Long Bars


Mu= 91428.11 k-in. Total moment on pile cap with offset
Mu= 3672.99 k-in./ft 1 ft strip design
d= 48.295 in.
As,required,structural,per ft= 1.456 in2/ft
As,required,structural,total= 36.235 in2
(4/3)As,required,structural,total= 48.313 in2
As,min,1=3(f'c)1/2bwd/fy= 45.619 in2
As,min,2=200bwd/fy= 48.086 in2
As,min,1 or 2, controlling= 48.086 in2
As,min,3=(0.0018 or 0.002)Ag= 31.185 in2
As,required= 48.086 in2
c b= 3.71 in.
l d= 40.129 in.
lavailable= 144.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 30.80
Prov. number of long bars = 17

190 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

191 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48.000 in.
d/2= 24.000 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 252.98 psi
b0= 288.00 in.
V c= 3497.23 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2622.92 kips
Vu= 2142.60 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.817

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48.000 in.
No. of piles outside d from face of the column = 8
2(fc')0.5= 126.49 psi
bd= 14337.79 in2
V c= 1813.60 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1360.20 kips
Vu= 810.79 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.596

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 15264.00 in.
V c= 1930.76 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1448.07 kips
Vu= 948.12 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.655

(continued)

192 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 48.000 in.
d/2= 24.000 in.
No. of piles outside face of the column = 22
wactual= 63.000 in. > d/2 Limit state not applicable
Vu= 2105.48 kips
0.5
4(fc') = 252.98 psi
32(fc')0.5= 2023.86 psi
b0= 288.000 in.
bs= 96.000 in.
k= 4.571 based on k=2(d/w)(1+d/c) acting at column face
V c= 1332.28 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 999.21 kips
Vu/f Vc= 2.107

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.295 in.
w'= 27.000 in.
w'/d= 0.559 OK, this limit state should be checked
Vu= 951.30 kips
M u= 85913.72 k-in.
Vud/Mu= 0.535
Mu/(Vud)= 1.870
k= -4.106
fVc= -2809.51 kips
Vu/f Vc= -0.339 **CONTROLLING** Vu/f Vc= -0.339

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 46.885 in.
w'= 63.000 in.
w'/d= 1.344 Limit state not applicable
Vu= 825.16 kips
M u= 83460.67 k-in.
Vud/Mu= 0.464
Mu/(Vud)= 2.157
k= -2.742
fVc= -1939.42 kips
Vu/f Vc= -0.425 **CONTROLLING** Vu/f Vc= -0.425

193 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

194 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 110.36 CY

Short Steel Bar Summary:


17 Total #11 Bars of length 24.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2203.2 lbs
Long Steel Bar Summary:
17 Total #11 Bars of length 26.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2348.4 lbs

Total weight of all steel = 4551.6 lbs or 2.276 tons

Comments:

195 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

24 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 55 in.
Pile Cap Dcap= 66 in.
Pile Cap Dimension A= 26.5 ft.
Pile Cap Dimension B= 24.892 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 54.955 in.
Reinf. Effective dlong bars = 56.295 in.
Reinf. Effective dshear checks = 56 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2201.28 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 23.459 in.

196 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Rounded Dimension c= 24 in.


(continued)

197 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 92099.23 k-in. Total moment on pile cap with offset
Mu= 3475.44 k-in./ft 1 ft strip design
d= 54.955 in.
As,required,structural,per ft= 1.208 in2/ft
As,required,structural,total= 31.999 in2
(4/3)As,required,structural,total= 42.665 in2
1/2
As,min,1=3(f'c) bwd/fy= 55.263 in2
As,min,2=200bwd/fy= 58.252 in2
As,min,1 or 2, controlling= 58.252 in2
As,min,3=(0.0018 or 0.002)Ag= 37.778 in2
As,required=
42.665 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.065
gs= 0.969 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 33.000 in2
As,required= 42.665 in2
cb= 3.64 in.
ld= 36.145 in.
lavailable= 134.352 in. OK; sufficient length available to develop bar
Req. number of short bars = 33.68
Prov. number of short bars = 16

Required Flexural Reinforcement - Long Bars


Mu= 93135.67 k-in. Total moment on pile cap with offset
Mu= 3741.59 k-in./ft 1 ft strip design
d= 56.295 in.
As,required,structural,per ft= 1.269 in2/ft
As,required,structural,total= 31.591 in2
(4/3)As,required,structural,total= 42.122 in2
As,min,1=3(f'c)1/2bwd/fy= 53.175 in2
As,min,2=200bwd/fy= 56.052 in2
As,min,1 or 2, controlling= 56.052 in2
As,min,3=(0.0018 or 0.002)Ag= 35.486 in2
As,required= 42.122 in2
cb= 3.71 in.
ld= 40.129 in.
lavailable= 144.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 26.98

198 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Prov. number of long bars = 16


(continued)

199 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 56.000 in.
d/2= 28.000 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 252.98 psi
b0= 320.00 in.
Vc= 4533.44 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3400.08 kips
Vu= 2003.94 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.589

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 56.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 16727.42 in2
Vc= 2115.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1586.90 kips
Vu= 902.83 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.569

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 56.000 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 126.49 psi
bd= 17808.00 in.
Vc= 2252.55 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1689.42 kips
Vu= 402.86 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.238

(continued)

200 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 56.000 in.

d/2= 28.000 in.


No. of piles outside face of the column = 24
wactual= 27.000 in. < d/2 This procedure applies
Vu= 2206.56 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 320.000 in.
bs= 96.000 in.

k= 13.827 based on k=2(d/w)(1+d/c) acting at column face


Vc= 4701.35 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 3526.01 kips
Vu/f Vc= 0.626 ****COMBINED**** Vu/f Vc= 0.931

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 56.295 in.
w'= 27.000 in.
w'/d= 0.480 OK, this limit state should be checked
Vu= 877.50 kips
Mu= 87919.98 k-in.
Vud/Mu= 0.562
Mu/(Vud)= 1.780
k= -3.873
fVc= -3089.01 kips
Vu/f Vc= -0.284

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 54.955 in.
w'= 53.352 in.
w'/d= 0.971 OK, this limit state should be checked
Vu= 879.62 kips
Mu= 86873.99 k-in.
Vud/Mu= 0.556
Mu/(Vud)= 1.797
k= -2.000
fVc= -1657.99 kips

201 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Vu/f Vc= -0.531


(continued)

202 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 134.37 CY

Short Steel Bar Summary:


16 Total #10 Bars of length 24.392 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 1682.2 lbs
Long Steel Bar Summary:
16 Total #11 Bars of length 26.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2210.3 lbs

Total weight of all steel = 3892.5 lbs or 1.946 tons

Comments:

203 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

204 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

26 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in. Note: Minimum cap dimensions
shown above. Actual dimensions
Minimum Pile Dimension dp= 20 in. provided to the left referencing
Pile Spacing, L= 6 ft. figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 23 in. A'= 17.063 ft.
Pile Cap Dcap= 68 in. B'= 19.444 ft.
Pile Cap Dimension A= 29.284 ft.
Pile Cap Dimension B= 26.5 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 56.885 in.
Reinf. Effective dlong bars = 58.295 in.
Reinf. Effective dshear checks = 58 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? NG
Results:
Column Size Determination
Net Column Capacity Pu= 2331.24 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 24.141 in.
Rounded Dimension c= 25 in.

205 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

206 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 89561.24 k-in. Total moment on pile cap with offset
Mu= 3058.37 k-in./ft 1 ft strip design
d= 56.885 in.
As,required,structural,per ft= 1.027 in2/ft
As,required,structural,total= 30.062 in2
(4/3)As,required,structural,total= 40.083 in2
As,min,1=3(f'c)1/2bwd/fy= 63.213 in2
As,min,2=200bwd/fy= 66.633 in2
As,min,1 or 2, controlling= 66.633 in2
As,min,3=(0.0018 or 0.002)Ag= 43.012 in2
As,required=
43.012 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.105
gs= 0.950 % steel concentrated of width B of long side A
As,required,structural,total,modfied = 31.562 in2
As,required= 43.012 in2
c b= 3.71 in.
l d= 40.129 in.
lavailable= 143.500 in. OK; sufficient length available to develop bar
Req. number of short bars = 27.55
Prov. number of short bars = 22

Required Flexural Reinforcement - Long Bars


Mu= 119564.68 k-in. Total moment on pile cap with offset
Mu= 4511.87 k-in./ft 1 ft strip design
d= 58.295 in.
As,required,structural,per ft= 1.479 in2/ft
As,required,structural,total= 39.190 in2
(4/3)As,required,structural,total= 52.253 in2
As,min,1=3(f'c)1/2bwd/fy= 58.622 in2
As,min,2=200bwd/fy= 61.793 in2
As,min,1 or 2, controlling= 61.793 in2
As,min,3=(0.0018 or 0.002)Ag= 38.923 in2
As,required= 52.253 in2
c b= 3.71 in.
l d= 40.129 in.
lavailable= 160.204 in. OK; sufficient length available to develop bar
Req. number of long bars = 33.47
Prov. number of long bars = 22

207 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

208 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 58.000 in.
d/2= 29.000 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 252.98 psi
b0= 332.00 in.
V c= 4871.43 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3653.57 kips
Vu= 1884.30 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.516

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 58.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 18444.00 in2
V c= 2333.00 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1749.75 kips
Vu= 865.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.495

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 58.000 in.
No. of piles outside d from face of the column = 8
2(fc')0.5= 126.49 psi
bd= 20381.66 in.
V c= 2578.10 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1933.57 kips
Vu= 759.60 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.393

(continued)

209 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 58.000 in.
d/2= 29.000 in.
No. of piles outside face of the column = 26
wactual= 26.500 in. < d/2 This procedure applies
Vu= 2337.14 kips
0.5
4(fc') = 252.98 psi
32(fc')0.5= 2023.86 psi
b0= 332.000 in.
bs= 100.000 in.
k= 14.533 based on k=2(d/w)(1+d/c) acting at column face
V c= 5330.99 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 3998.25 kips
Vu/f Vc= 0.585

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 58.295 in.
w'= 26.500 in.
w'/d= 0.455 OK, this limit state should be checked
Vu= 1203.16 kips
M u= 112286.81 k-in.
Vud/Mu= 0.625
Mu/(Vud)= 1.601
k= -2.169
fVc= -1906.90 kips
Vu/f Vc= -0.631 **CONTROLLING** Vu/f Vc= -0.631

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 56.885 in.
w'= 26.500 in.
w'/d= 0.466 OK, this limit state should be checked
Vu= 1079.11 kips
M u= 83064.89 k-in.
Vud/Mu= 0.739
Mu/(Vud)= 1.353
k= 0.496
fVc= 470.28 kips
Vu/f Vc= 2.295 **CONTROLLING** Vu/f Vc= 2.295

210 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

211 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 153.82 CY

Short Steel Bar Summary:


22 Total #11 Bars of length 26.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 3039.1 lbs
Long Steel Bar Summary:
22 Total #11 Bars of length 28.784 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 3364.5 lbs

Total weight of all steel = 6403.6 lbs or 3.202 tons

Comments:

212 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

28 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Load Factor = 1.6
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 6 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin, recommended= 55 in.
Pile Cap Dcap= 68 in.
Pile Cap Dimension A= 29.284 ft.
Pile Cap Dimension B= 26.5 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 56.955 in.
Reinf. Effective dlong bars = 58.295 in.
Reinf. Effective dshear checks = 58 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2528.60 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 25.143 in.
Rounded Dimension c= 26 in.
(continued)

213 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 103487.96 k-in. Total moment on pile cap with offset
Mu= 3533.94 k-in./ft 1 ft strip design
d= 56.955 in.
As,required,structural,per ft= 1.185 in2/ft
As,required,structural,total= 34.689 in2
(4/3)As,required,structural,total= 46.252 in2
As,min,1=3(f'c)1/2bwd/fy= 63.291 in2
As,min,2=200bwd/fy= 66.715 in2
As,min,1 or 2, controlling= 66.715 in2
As,min,3=(0.0018 or 0.002)Ag= 43.012 in2
As,required=
46.252 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.105
gs= 0.950 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 36.420 in2
As,required= 46.252 in2
cb = 3.64 in.
ld= 36.145 in.
lavailable= 143.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 36.51
Prov. number of short bars = 28

Required Flexural Reinforcement - Long Bars


Mu= 126982.08 k-in. Total moment on pile cap with offset
Mu= 4791.78 k-in./ft 1 ft strip design
d= 58.295 in.
As,required,structural,per ft= 1.571 in2/ft
As,required,structural,total= 41.642 in2
(4/3)As,required,structural,total= 55.522 in2
1/2
As,min,1=3(f'c) bwd/fy= 58.622 in2
As,min,2=200bwd/fy= 61.793 in2
As,min,1 or 2, controlling= 61.793 in2
As,min,3=(0.0018 or 0.002)Ag= 38.923 in2
As,required= 55.522 in2
cb = 3.71 in.
ld= 40.129 in.
lavailable= 159.704 in. OK; sufficient length available to develop bar
Req. number of long bars = 35.56
Prov. number of long bars = 23

214 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

215 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 58.000 in.
d/2= 29.000 in.
No. of piles outside d/2 from face of the column = 26
4(fc')0.5= 252.98 psi
b 0= 336.00 in.
Vc= 4930.12 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3697.59 kips
Vu= 2339.24 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.633

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 58.000 in.
No. of piles outside d from face of the column = 9
2(fc')0.5= 126.49 psi
bd= 18444.00 in2
Vc= 2333.00 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1749.75 kips
Vu= 837.54 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.479

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 58.000 in.
No. of piles outside d from face of the column = 12
2(fc')0.5= 126.49 psi
bd= 20381.66 in.
Vc= 2578.10 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1933.57 kips
Vu= 1243.94 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.643

(continued)

216 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 58.000 in.

d/2= 29.000 in.


No. of piles outside face of the column = 28
wactual= 26.000 in. < d/2 This procedure applies
Vu= 2534.99 kips
4(fc')0.5= 252.98 psi
0.5
32(fc') = 2023.86 psi
b 0= 336.000 in.
b s= 104.000 in.
k= 14.414 based on k=2(d/w)(1+d/c) acting at column face
Vc= 5498.98 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 4124.23 kips
Vu/f Vc= 0.615

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 58.295 in.
w'= 26.000 in.
w'/d= 0.446 OK, this limit state should be checked
Vu= 1303.35 kips
Mu= 118573.78 k-in.
Vud/Mu= 0.641
Mu/(Vud)= 1.561
k= -1.768
fVc= -1554.93 kips
Vu/f Vc= -0.838

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 56.955 in.
w'= 26.000 in.
w'/d= 0.457 OK, this limit state should be checked
Vu= 1051.45 kips
Mu= 96723.66 k-in.
Vud/Mu= 0.619
Mu/(Vud)= 1.615
k= -2.312
fVc= -2194.61 kips
Vu/f Vc= -0.479

217 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

218 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 162.87 CY

Short Steel Bar Summary:


28 Total #10 Bars of length 26.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 3138.0 lbs
Long Steel Bar Summary:
23 Total #11 Bars of length 28.784 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 3517.4 lbs

Total weight of all steel = 6655.4 lbs or 3.328 tons

Comments:

219 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

30 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Load Factor = 1.6 ###
Pile Type = Steel Bar No.
Pile Shape = Round ###
Concrete Comp. Strength, f'c= 4 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 550 tons ###
Pile Allowable Load (ASD) = 1100 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. Note: Minimum cap dimensions ###
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions ###
provided to the left referencing
Pile Spacing, L= 6 ft. figure below. ###
Pile Edge Distance, E= 36 in. Short hook ad
Pile Cap Dmin, recommended= 55 in. Long hook ad
Pile Cap Dcap= 59 in. Short Bar Dia
Pile Cap Dimension A= 36 ft. Short Bar Are
Pile Cap Dimension B= 30 ft. Steel pile em
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 47.885 in.
Reinf. Effective dlong bars = 49.295 in. If given pile is
Reinf. Effective dshear checks = 49 in.
High capacity pile selected - special details required - see CRSI Pile Cap Design Guide Equivalent Pi
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size d=
CRSI Limit State 1 Adequate? NG d/2=
CRSI Limit State 2 Adequate? NG CRSI Limit State P1 Adequate? OK Diameter for
CRSI Limit State 3 Adequate? NG CRSI Limit State P2 Adequate? NG Area in shear
CRSI Limit State 4 Adequate? NG CRSI Limit State P3 Adequate? NG 4(fc')0.5=
CRSI Limit State 5 Adequate? #DIV/0! CRSI Limit State P4 Adequate? NG Vc=
CRSI Limit State 6 Adequate? NG
Results: Vu=
Column Size Determination Vu/f Vc=
Net Column Capacity Pu= 51525.60 kips (reduced by C6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 113.496 in.
Rounded Dimension c= 114 in.
(continued)

221 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 1701774.52 k-in. Total moment on pile cap with offset
Mu= 47271.51 k-in./ft 1 ft strip design
d= 47.885 in.
As,required,structural,per ft= #NUM! in2/ft
As,required,structural,total= #NUM! in2
(4/3)As,required,structural,total= #NUM! in2
As,min,1=3(f'c)1/2bwd/fy= 65.416 in2
As,min,2=200bwd/fy= 68.954 in2
As,min,1 or 2, controlling= 68.954 in2
As,min,3=(0.0018 or 0.002)Ag= 45.878 in2
As,required=
#NUM! in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.200 c. to c. spacing of l
gs= 0.909 % steel concentrated of width B of long side A concrete cover =
As,required,structural,total,modfied= #NUM! in2 cb=

As,required= #NUM! in2


cb = 3.71 in. y t=

ld= 40.129 in. ye=

lavailable= 120.000 in. OK; sufficient length available to develop bar ys=

Req. number of short bars = #NUM! (cb+Ktr)/db=


Prov. number of short bars = 33 ld=
lavailable=

Required Flexural Reinforcement - Long Bars


Mu= 2126144.53 k-in. Total moment on pile cap with offset
Mu= 70871.48 k-in./ft 1 ft strip design
d= 49.295 in. c. to c. spacing of l
As,required,structural,per ft= #NUM! in2/ft concrete cover =
As,required,structural,total= #NUM! in2 cb=

(4/3)As,required,structural,total= #NUM! in2


1/2
As,min,1=3(f'c) bwd/fy= 56.118 in2 yt=

As,min,2=200bwd/fy= 59.154 in2 ye=

As,min,1 or 2, controlling= 59.154 in2 ys=

As,min,3=(0.0018 or 0.002)Ag= 38.232 in2 (cb+Ktr)/db=

As,required= #NUM! in2 ld=

cb = 3.71 in. lavailable=

ld= 40.129 in.


lavailable= 156.000 in. OK; sufficient length available to develop bar
Req. number of long bars = #NUM!
Prov. number of long bars = 26

222 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

223 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 - distance from
d= 49.000 in. distance from
d/2= 24.500 in. distance from
No. of piles outside d/2 from face of the column = 24 distance from
4(fc')0.5= 252.98 psi distance from
b 0= 652.00 in. distance from
0.5
Vc= 8082.28 kips based on Vc=4(fc') b0d acting at d/2 from column face
fVc= 6061.71 kips Limit State Al
Vu= 41183.32 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 6.794

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 - distance from
d= 49.000 in. distance from
No. of piles outside d from face of the column = 10 distance from
2(fc')0.5= 126.49 psi distance from
bd= 17640.00 in2
Vc= 2231.30 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1673.48 kips Limit State Al
Vu= 17275.50 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 10.323

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 - distance from
d= 49.000 in. distance from
No. of piles outside d from face of the column = 6 distance from
2(fc')0.5= 126.49 psi
bd= 21168.00 in.
Vc= 2677.56 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 2008.17 kips Limit State Al
Vu= 10298.04 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 5.128

(continued)

224 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 - Make sure lar
d= 49.000 in. NG, but answ
d/2= 24.500 in. 32(fc')0.5=
No. of piles outside face of the column = 30 ###
wactual -18.000 in. < d/2 This procedure applies ###
Vu 51632.10 kips 4(fc')0.5=
4(fc')0.5= 252.98 psi 32(fc')0.5=
32(fc')0.5= 2023.86 psi b0=
b 0= 652.000 in. Limit State Al
b s= 456.000 in. k=
k= -7.785 based on k=2(d/w)(1+d/c) acting at column face ###
Vc= -11000.88 kips based on Vc=k(fc')0.5bsd acting at column face ###
fVc= -8250.66 kips ###
Vu/f Vc= -6.258 ****COMBINED**** Vu/f Vc= 3.129
###
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 - Limit State Al
d= 49.295 in. w'=
w'= -18.000 in. w'/d=
w'/d= 0.000 OK, this limit state should be checked Vu=
Vu= 25930.95 kips M u=
Mu= 1388310.53 k-in. Vud/Mu=
Vud/Mu= 0.921 Mu/(Vud)=
Mu/(Vud)= 1.086 k=
k= #DIV/0!
fVc= #DIV/0! kips
Vu/f Vc= #DIV/0! **CONTROLLING** Vu/f Vc= -10.571

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 - Limit State Al
d= 47.885 in. w'=
w'= 18.000 in. w'/d=
w'/d= 0.376 OK, this limit state should be checked Vu=
Vu= 20684.58 kips M u=
Mu= 1113701.67 k-in. Vud/Mu=
Vud/Mu= 0.889 Mu/(Vud)=
Mu/(Vud)= 1.124 k=
k= 3.646
fVc= 3577.12 kips
Vu/f Vc= 5.782 **CONTROLLING** Vu/f Vc= 5.782

225 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

(continued)

226 of 228 09/13/2020 12:25:59


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars d=


Concrete Summary: d/2=
Quantity = 196.67 CY Diameter for
Area in shear
Short Steel Bar Summary: 4(fc')0.5=
33 Total #11 Bars of length 29.500 ft (per bar) Vc=
0 Total Hooks of length 1.728 ft (per bar)
Weight = 5172.3 lbs Vu=
Long Steel Bar Summary:
26 Total #11 Bars of length 35.500 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 4904.0 lbs d=
d/2=
Total weight of all steel = 10076.3 lbs or 5.038 tons Straight dime
Round dimen
Area in shear
Comments: 4(fc')0.5=
Vc=

Vu=

d=
d/2=
Length dimen
Area in shear
4(fc')0.5=
Vc=

Vu=
Vu/f Vc=

d=
dcritical=
diagonal =
Area in shear
2(fc')0.5=
Vc=

227 of 228 09/13/2020 12:25:59