You are on page 1of 206

"CRSI-PILECAP" --- PILECAP DESIGN AND ANALYSIS SPREADSHEET

Program Description:

"CRSI-PILECAP" is a spreadsheet program written in MS-Excel for the design and analysis of rigid pile
caps. Pile caps are designed and analyzed in accordance with ACI 318-11 with modifications as necessary
to account for beam shear and punching shear when piles are placed inside the ACI assumed shear failure plane.
Users input the pile type/material, pile shape, pile allowable load, pile size, pile cap material properties,
pile cap depth, bar size, and minimum pile eccentrity (which can also be used to increase pile cap moment demand
if so desired). Design requires the user to simply yet interatively choose a minimum design depth that satisfies
all limit states required by ACI and those recommended by CRSI. The load combination used to change from pile
allowable load to factored load is 1.6(D+Lfloor) and the assumed strength resistance factor for shear is f = 0.85.
The chosen load factor and strength reduction factor were chosen to provide a factor of safety against shear failure
equivalent to that which was used in the CRSI Design Handbook (2008).

This program is a workbook consisting of ten (27) worksheets, described as follows:

Worksheet Name Description


Doc This documentation sheet
2 Pile Cap Pile Cap Design for 2 Piles
3 Pile Cap Pile Cap Design for 3 Piles (Round Column)
4 Pile Cap Pile Cap Design for 4 Piles
5 Pile Cap Pile Cap Design for 5 Piles
6 Pile Cap Pile Cap Design for 6 Piles
7 Pile Cap Pile Cap Design for 7 Piles (Round Column)
8 Pile Cap Pile Cap Design for 8 Piles
9 Pile Cap Pile Cap Design for 9 Piles
10 Pile Cap Pile Cap Design for 10 Piles
11 Pile Cap Pile Cap Design for 11 Piles
12 Pile Cap Pile Cap Design for 12 Piles
13 Pile Cap Pile Cap Design for 13 Piles
14 Pile Cap Pile Cap Design for 14 Piles
15 Pile Cap Pile Cap Design for 15 Piles
16 Pile Cap Pile Cap Design for 16 Piles
17 Pile Cap Pile Cap Design for 17 Piles
18 Pile Cap Pile Cap Design for 18 Piles
19 Pile Cap Pile Cap Design for 19 Piles
20 Pile Cap Pile Cap Design for 20 Piles
21 Pile Cap Pile Cap Design for 21 Piles
22 Pile Cap Pile Cap Design for 22 Piles
23 Pile Cap Pile Cap Design for 23 Piles
24 Pile Cap Pile Cap Design for 24 Piles
26 Pile Cap Pile Cap Design for 26 Piles
28 Pile Cap Pile Cap Design for 28 Piles
30 Pile Cap Pile Cap Design for 30 Piles

Program Assumptions and Limitations:


General Note: This spreadsheet is part of the CRSI Pile Cap Design Guide (2015). This program should only be used
in conjunction with the design requirements and recommendations as presented in the CRSI Pile Cap Design Guide.
For a complete list of terms used in this spreadsheet, please see the CRSI Pile Cap Design Guide (2015).
1. The CRSI-PILECAP worksheets assume rigid cap load distribution to each pile (i.e., equal load distribution)
for a pile group.
2. The tabulated designs are based upon the use of a square reinforced concrete column of at least the minimum size indicated or
a structural steel column on a steel base plate such that the section half-way between the column face
and the edge of the base plate is equivalent to the size of the column.
3. The tabulated designs are adequate (and conservative) for rectangular columns or steel base
plates if the short side or section is equal to the minimum tabulated column size.
4. A minimum embedment of 6 inches has been established as good practice with structural
steel shapes to avoid use of cover plates for bearing. If precast, concrete, or timber piles are to be used in the tabulated
designs, a minimum embedment of 4 inches is usually sufficient.
5. A minimum pile spacing equal to the maximum of (a) 3 ft o.c., (b) 3 times the pile dimension,
and (c) 2 ft clear between piles is used in the worksheets. The 3 times the pile dimension requirement is based on current
geotechnical recommendations that result in expected maximum pile capacities.
6. Note that some tabulated designs show dimensions on the line below. These dimensions are for use with “clipped corners”
to save concrete. In other words, the “clipped corner” dimensions are the truncated dimensions
of the pile cap with the corners removed.
7. Pile Allowable Load is tabulated in tons, (D + Lfloor), as is usually done in accepted practice. The
range shown, 40 tons to 400 tons, covers the usual range for precast concrete or structural steel piles.
An average load factor of 1.6 is conservatively assumed for pile cap design.
8. For pile caps with 2, 3, 4, 5, 6, 7, or 9 piles, all reinforcing bars must be provided with standard
end hooks. For pile caps with 8, 10, 11, or 12 piles, only the short reinforcing bars must be provided with
end hooks, and should be placed as the lower layer. As an alternative to hooked bars, the bar ends can be headed.
9. This program contains numerous “comment boxes” which contain a wide variety of information including
explanations of input or output items, equations used, data tables, etc. (Note: presence of a “comment box”
is denoted by a “red triangle” in the upper right-hand corner of a cell. Merely move the mouse pointer to the
desired cell to view the contents of that particular "comment box".)
10.The limit states listed in the output section of each worksheet are defined and shown graphically
in the CRSI Pile Cap Design Guide.

Terms Used in the Input Section of the Worksheets:


Pile Type - concrete, steel, or wood piling may be selected
Pile Shape - round or square piles may be selected; H-piles are considered square piles (see CRSI Pile Cap
Design Guide); pipe piles are considered round piles (see CRSI Pile Cap Design Guide)
fc' - 28 day strength of concrete (limited to 3,000 or 4,000 psi)
fy - yield strength of steel reinforcement; limited to 60 ksi
Accidential Pile Offset - pile location tolerence; increases shear and bending demands on pile cap;
minimum set as CRSI recommended value of 3 in.; maximum value arbitrarily set at 9 in.
Pile Allowable Load (ASD) - Allowable compressive load on pile (provided by geotechnical engineer). Ultimate pile
load (as determined by geotechnical engineers) are typically 1.6 to 2.0 times the ASD allowable load.
Values between 40 tons and 400 tons may be selected.
Minimum Pile Embedment - the minimum pile embedment is set at 6 in. for steel piles and 4 in. for concrete
and wood piles.
Clear Cover Over Top of Pile - the clear distance from the top of the pile to the first layer of reinforcement;
the minimum value is set as the CRSI recommended minimum of 3 in.; the maximum value is arbitrarily set at 5 in.
Minimum Pile Dimension dp - is the pile diameter for round columns and the pile side dimension for square piles
L - minimum center to center pile spacing; set by CRSI recommendations; see comment box; (automatically
calculated)
E - minimum edge distance from center of pile to edge of concrete; set by CRSI recommendations (see comment
box)
Dmin,recommended - minimum recommended pile cap thickness based on limit state P4 (CRSI Pile Cap Design Guide)
Dcap - user selected pile cap thickness; all resulting limit state design checks must be "ok"
A - minimum pile cap width (long direction); automatically calculated based on pile spacing and edge distance
B - minimum pile cap width (short direction); automatically calculated based on pile spacing and edge distance
Short Bars Size (No.) - selected reinforcement size for bars spanning in the "B" direction
Long Bars Size (No.) - selected reinforcement size for bars spanning in the "A" direction
dshort bars - effective depth of concrete from top of cap to center of short bars (automatically calculated)
dlong bars - effective depth of concrete from top of cap to center of long bars (automatically calculated)
dshear checks - the effective depth of the concrete for shear limit states; based on the Minimum Pile Embedment
plus the Clear Cover Over Top of Pile plus 1 inch; for steel piles, the value is D minus 10 in.; for concrete/wood piles
the value is D minus 8 in. (automatically calcuated)
Special Notes for Comparing Program Output with Tabulated Designs in Pile Cap Design Guide:
1. For the 2 Pile Cap, the previous CRSI Design Handbook (2008) added an extra degree of conservatism when
determining the one way shear nominal strength. Pile cap instability (weak axis) and one way action were
considerations. The CRSI Pile Cap Design Guide (2015) and this software program also include this extra
conservatism. See 2 Pile Cap tab and Limit State 5 calculations for more information.
2. For the 3 Pile Cap, one way shear is possible on either side of the column (i.e., with 1 pile or 2 piles causing
demand and and reduced area towards the pile). The program considers both conditions and presents the worst
case results.
3. For pile caps with different distances w when considering orthogonal action and two way shear (e.g., 6 Pile Cap
and 8 Pile Cap), the program uses a slightly more conservative approach than the previous CRSI Design Handbook
(2008) for determining the nominal shear strength for Limit State 4. The previous approach used the average
w value (considering both directions) where this program uses the average demand capacity ratio for each w.
4. CRSI Limit State P4 is very restrictive for thicker pile caps and may not be entirely applicable in some cases.
The spreadsheet conservatively applies it to all caps with corner piles but assumes the one way shear strength
is limited to 2(fc')1/2 which is very conservative when the critical distance from the cap is limited to 13 in.
As a result, the design guide review committee has reviewed the results for the tabulated designs and believes that
increasing the one way shear strength to 3(f c')1/2 is still conservative for these configurations.
"CRSI-PILECAP" Program
Version 1.0

2 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Pile Type = Steel ###
Pile Shape = Round Bar No.
Concrete Comp. Strength, f'c= 4 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 120 tons ###
Pile Allowable Load (ASD) = 240 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Minimum Pile Dimension dp= 12 in. Note: Minimum cap dimensions ###
Pile Spacing, L= 3 ft.
shown above. Actual dimensions ###
provided to the left referencing
Pile Edge Distance, E= 21 in. figure below. ###
Pile Cap Dmin,recommended= 35 in. Short hook
Pile Cap Dcap= 42 in. Long hook a
Pile Cap Dimension A= 6.5 ft. Short Bar D
Pile Cap Dimension B= 3.5 ft. Short Bar Ar
Short Bars Size (No.) = 4 Steel pile em
Long Bars Size (No.) = 9
Reinf. Effective dshort bars = 31.622 in.
Reinf. Effective dlong bars = 32.436 in.
Reinf. Effective dshear checks = 32 in. If given pile

Design Checks: Equivalent P


Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK d=
CRSI Limit State 2 Adequate? OK d/2=
CRSI Limit State 3 Adequate? Not applicable to this pilecap configuration Diameter fo
CRSI Limit State 4 Adequate? Not applicable to this pilecap configuration Area in shea
CRSI Limit State 5 Adequate? OK 4(fc')0.5=
CRSI Limit State 6 Adequate? Not applicable to this pilecap configuration Vc=
Results:
Column Size Determination Vu=
Net Column Capacity Pu= 748.89 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 13.683 in.
Rounded Dimension c= 14 in.
(continued)

5 of 206 09/13/2020 12:28:15


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 0 k-in. Total moment on pile cap with offset
Mu= 0 k-in./ft 1 ft strip design
d= 31.622 in.
As,required,structural,per ft= 0.009 in2/ft
As,required,structural,total= 0.060 in2
(4/3)As,required,structural,total= 0.081 in2
1/2
As,min,1=3(f'c) bwd/fy= 7.800 in2
As,min,2=200bwd/fy= 8.222 in2
As,min,1 or 2, controlling= 8.222 in2
As,min,3=(0.0018 or 0.002)Ag= 5.897 in2
As,required=
5.897 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.857
g s= 0.7 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 0.079 in2
As,required= 5.897 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
y e= 1 Use 1.0 for no epoxy coating
ldh= 6.641 in. OK; sufficient length available to develop hook
Req. number of short bars = 30.03
Prov. number of short bars = 14

Required Flexural Reinforcement - Long Bars


Mu= 6565.62 k-in. Total moment on pile cap with offset
Mu= 1875.89 k-in./ft 1 ft strip design
d= 32.436 in.
As,required,structural,per ft= 1.109 in2/ft
As,required,structural,total= 3.882 in2
(4/3)As,required,structural,total= 5.176 in2
As,min,1=3(f'c)1/2bwd/fy= 4.308 in2
As,min,2=200bwd/fy= 4.541 in2
As,min,1 or 2, controlling= 4.541 in2
As,min,3=(0.0018 or 0.002)Ag= 3.175 in2
As,required= 4.541 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 14.982 in. OK; sufficient length available to develop hook
Req. number of long bars = 4.54
Prov. number of long bars = 6

6 of 206 09/13/2020 12:28:15


"CRSI-PILECAP" Program
Version 1.0

(continued)

7 of 206 09/13/2020 12:28:15


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 32 in. distance fro
d/2= 16 in. distance fro
No. of piles outside d/2 from face of the column = 0 distance fro
4(fc')0.5= 252.98 psi
b0= 84 in.
Vc= 680.02 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face Limit State A
f Vc= 578.01 kips
Vu= -6.77 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.012

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 32 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 126.49 psi
bd= 1344.00 in2 Limit State A
0.5
Vc= 170.00 kips based on Vc=2(fc') bd acting at d from column face
fVc= 144.50 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 32.436 in.
w'= 14 in.
w'/d= 0.432 OK, this limit state should be checked
Vu= 376.16 kips
Mu= 5250.56 k-in. Limit State A
Vud/Mu= 2.324
Mu/(Vud)= 0.430
k= 10.000
fVc= 732.36 kips
Vu/f Vc= 0.514
Conservatively assuming w'/d=1.0,
Vud/Mu= 2.324
Mu/(Vud)= 0.430
k= 5.169
fVc= 378.57 kips
Vu/f Vc= 0.994

8 of 206 09/13/2020 12:28:15


"CRSI-PILECAP" Program
Version 1.0

(continued)

9 of 206 09/13/2020 12:28:15


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 2.95 CY

Short Steel Bar Summary:


14 Total #4 Bars of length 3.000 ft (per bar)
28 Total Hooks of length 0.565 ft (per bar)
Weight = 38.6 lbs
Long Steel Bar Summary:
6 Total #9 Bars of length 6.000 ft (per bar)
12 Total Hooks of length 1.383 ft (per bar)
Weight = 178.8 lbs

Total weight of all steel = 217.5 lbs or 0.109 tons

Comments:

10 of 206 09/13/2020 12:28:15


"CRSI-PILECAP" Program
Version 1.0

3 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 120 tons
Pile Allowable Load (ASD) = 240 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in. Note: Minimum cap dimensions
Minimum Pile Dimension dp= 12 in. shown above. Actual dimensions
provided to the left referencing
Pile Spacing, L= 3 ft. figure below.
Pile Edge Distance, E= 21 in.
Pile Cap Dmin,recommended= 35 in. A'= 2.021 ft.
Pile Cap Dcap= 41 in. B'= 2.219 ft.
Pile Cap Dimension A= 6.5 ft.
Pile Cap Dimension B= 6.098 ft.
Short Bars Size (No.) = 10
(All Three Directions)
Reinf. Effective dshort bars = 31.365 in.
Reinf. Effective dlong bars = 32.000 in.
Reinf. Effective dshear checks = 31 in.

Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? Not Applicable CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? Not Applicable CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1126.62 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 18.937 in.
Rounded Dimension c= 19 in.
(continued)

11 of 206 09/13/2020 12:28:15


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Three Ways


Mu= 5297.51 k-in. Total moment on pile cap with offset
Mu= 2387.53 k-in./ft 1 ft strip design
d= 31.365 in.
As,required,structural,per ft= 1.470 in2/ft
As,required,structural,total= 3.263 in2
(4/3)As,required,structural,total= 4.350 in2
1/2
As,min,1=3(f'c) bwd/fy= 2.641 in2
As,min,2=200bwd/fy= 2.784 in2
As,min,1 or 2, controlling= 2.784 in2
As,min,3=(0.0018 or 0.002)Ag= 1.965 in2
As,required= 3.263 in2
E'=E-Offset = 18.00 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 16.868 in. OK; sufficient length available to develop hook
Req. number of short bars = 2.58
Prov. number of short bars = 4

(continued)

12 of 206 09/13/2020 12:28:15


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 31 in.
d/2= 15.5 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 252.98 psi
b0= 157.075 in.
Vc= 1231.85 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1047.07 kips
Vu= -22.58 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.022

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 31 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 797.65 in2
Vc= 100.90 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 85.76 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.0000

(continued)

13 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 31 in.
d/2= 15.5 in.
No. of piles outside face of the column = 3
wactual= 14.285 in. < d/2 This procedure applies
Vu= 1128.24 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 157.075 in.
bs= 59.689 in.
k= 11.421 based on k=2(d/w)(1+d/c) acting at column face
Vc= 1336.61 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1136.12 kips
Vu/f Vc= 0.993

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 30.095 in.
w'= 14.272 in.
w'/d= 0.474 OK, this limit state should be checked
Vu= 384.00 kips
Mu= 5480.45 k-in.
Vud/Mu= 2.109
Mu/(Vud)= 0.474
k= 10.000
fVc= 995.41 kips
Vu/f Vc= 0.386 Above 0.609 Below 0.609 Controlling
(continued)

14 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 3.92 CY

All Steel Bar Summary:


12 Total #10 Bars of length 6.000 ft (per bar)
24 Total Hooks of length 1.557 ft (per bar)
Weight = 471.4 lbs

Total weight of all steel = 471.4 lbs or 0.236 tons

Comments:

15 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

16 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

4 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 120 tons
Pile Allowable Load (ASD) = 240 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 12 in. Note: Minimum cap dimensions
Pile Spacing, L= 3 ft. shown above. Actual dimensions
provided to the left referencing
Pile Edge Distance, E= 21 in. figure below.
Pile Cap Dmin,recommended= 35 in.
Pile Cap Dcap= 39 in.
Pile Cap Dimension A= 6.5 ft.
Pile Cap Dimension B= 6.5 ft.
Short Bars Size (No.) = 9
Long Bars Size (No.) = 9
Reinf. Effective dshort bars = 28.308 in.
Reinf. Effective dlong bars = 29.436 in.
Reinf. Effective dshear checks = 29 in.

Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1503.05 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 19.385 in.
Rounded Dimension c= 20 in.
(continued)

17 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 12043.80 k-in. Total moment on pile cap with offset
Mu= 1852.89 k-in./ft 1 ft strip design
d= 28.308 in.
As,required,structural,per ft= 1.263 in2/ft
As,required,structural,total= 8.207 in2
(4/3)As,required,structural,total= 10.942 in2
1/2
As,min,1=3(f'c) bwd/fy= 6.982 in2
As,min,2=200bwd/fy= 7.360 in2
As,min,1 or 2, controlling= 7.360 in2
As,min,3=(0.0018 or 0.002)Ag= 5.476 in2
As,required=
8.207 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
gs= 1 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 8.207 in2
As,required= 8.207 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 14.982 in. OK; sufficient length available to develop hook
Req. number of short bars = 8.21
Prov. number of short bars = 11

Required Flexural Reinforcement - Long Bars


Mu= 12043.80 k-in. Total moment on pile cap with offset
Mu= 1852.89 k-in./ft 1 ft strip design
d= 29.436 in.
As,required,structural,per ft= 1.212 in2/ft
As,required,structural,total= 7.876 in2
(4/3)As,required,structural,total= 10.501 in2
As,min,1=3(f'c)1/2bwd/fy= 7.261 in2
As,min,2=200bwd/fy= 7.653 in2
As,min,1 or 2, controlling= 7.653 in2
As,min,3=(0.0018 or 0.002)Ag= 5.476 in2
As,required= 7.876 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 14.982 in. OK; sufficient length available to develop hook
Req. number of long bars = 7.88
Prov. number of long bars = 11

18 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

19 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 29 in.
d/2= 14.5 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 252.98 psi
b0= 196 in.
Vc= 1437.95 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1222.26 kips
Vu= -19.95 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.016

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 29 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 2262.00 in2
Vc= 286.12 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 243.20 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 29 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 2262.00 in2
Vc= 286.12 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 243.20 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000

(continued)

20 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 29 in.
d/2= 14.5 in.
No. of piles outside face of the column = 4
wactual= 11.000 in. < d/2 This procedure applies
Vu= 1505.21 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 196.000 in.
bs= 80.000 in.
k= 12.918 based on k=2(d/w)(1+d/c) acting at column face
Vc= 1895.48 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1611.16 kips
Vu/f Vc= 0.934

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 29.436 in.
w'= 11.000 in.
w'/d= 0.374 OK, this limit state should be checked
Vu= 755.75 kips
Mu= 8270.34 k-in.
Vud/Mu= 2.690
Mu/(Vud)= 0.372
k= 10.000
fVc= 1234.30 kips
Vu/f Vc= 0.612

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 28.308 in.
w'= 11 in.
w'/d= 0.389 OK, this limit state should be checked
Vu= 755.75 kips
Mu= 8270.34 k-in.
Vud/Mu= 2.587
Mu/(Vud)= 0.387
k= 10.000
fVc= 1187.01 kips
Vu/f Vc= 0.637
(continued)

21 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 5.09 CY

Short Steel Bar Summary:


11 Total #9 Bars of length 6.000 ft (per bar)
22 Total Hooks of length 1.383 ft (per bar)
Weight = 327.8 lbs
Long Steel Bar Summary:
11 Total #9 Bars of length 6.000 ft (per bar)
22 Total Hooks of length 1.383 ft (per bar)
Weight = 327.8 lbs

Total weight of all steel = 655.7 lbs or 0.328 tons

Comments:

22 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

23 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

5 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 120 tons
Pile Allowable Load (ASD) = 240 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in. Note: Minimum cap dimensions
Minimum Pile Dimension dp= 12 in. shown above. Actual dimensions
provided to the left referencing
Pile Spacing, L= 3 ft. figure below.
Pile Edge Distance, E= 21 in.
Pile Cap Dmin,recommended= 35 in.
Pile Cap Dcap= 43 in.
Pile Cap Dimension A= 7.7426 ft.
Pile Cap Dimension B= 7.7426 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 32.095 in.
Reinf. Effective dlong bars = 33.365 in.
Reinf. Effective dshear checks = 33 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size
CRSI Limit State 1 Adequate? NG
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1868.44 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.613 in.
Rounded Dimension c= 22 in.
(continued)

25 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 17164.53 k-in. Total moment on pile cap with offset
Mu= 2216.89 k-in./ft 1 ft strip design
d= 32.095 in.
As,required,structural,per ft= 1.338 in2/ft
As,required,structural,total= 10.357 in2
(4/3)As,required,structural,total= 13.810 in2
1/2
As,min,1=3(f'c) bwd/fy= 8.167 in2
As,min,2=200bwd/fy= 9.940 in2
As,min,1 or 2, controlling= 9.940 in2
As,min,3=(0.0018 or 0.002)Ag= 7.191 in2
As,required=
10.357 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
gs= 1 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 10.357 in2
As,required= 10.357 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 19.477 in. NG; insufficient length available to develop hook
Req. number of short bars = 8.18
Prov. number of short bars = 14

Required Flexural Reinforcement - Long Bars


Mu= 17164.53 k-in. Total moment on pile cap with offset
Mu= 2216.89 k-in./ft 1 ft strip design
d= 33.365 in.
As,required,structural,per ft= 1.283 in2/ft
As,required,structural,total= 9.932 in2
(4/3)As,required,structural,total= 13.243 in2
As,min,1=3(f'c)1/2bwd/fy= 8.490 in2
As,min,2=200bwd/fy= 10.333 in2
As,min,1 or 2, controlling= 10.333 in2
As,min,3=(0.0018 or 0.002)Ag= 7.191 in2
As,required= 10.333 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 19.477 in. NG; insufficient length available to develop hook
Req. number of long bars = 8.16
Prov. number of long bars = 14

26 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

27 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 33 in.
d/2= 16.5 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 219.09 psi
b0= 220 in.
Vc= 1590.59 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1352.00 kips
Vu= 1502.51 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 1.111

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 33 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 3066.07 in2
Vc= 335.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 285.49 kips
Vu= -1.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.005

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 33 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 3066.07 in2
Vc= 335.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 285.49 kips
Vu= -1.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.005

(continued)

28 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 33 in.
d/2= 16.5 in.
No. of piles outside face of the column = 4
wactual= 17.456 in. > d/2 Limit state not applicable
Vu= 1487.34 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 220.000 in.
bs= 88.000 in.
k= 9.453 based on k=2(d/w)(1+d/c) acting at column face
Vc= 1503.51 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 1277.98 kips
Vu/f Vc= 1.164

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 33.365 in.
w'= 17.456 in.
w'/d= 0.523 OK, this limit state should be checked
Vu= 748.33 kips
Mu= 13057.13 k-in.
Vud/Mu= 1.912
Mu/(Vud)= 0.523
k= 8.764
fVc= 1264.90 kips
Vu/f Vc= 0.592

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 32.095 in.
w'= 17.4556 in.
w'/d= 0.544 OK, this limit state should be checked
Vu= 748.33 kips
Mu= 13057.13 k-in.
Vud/Mu= 1.839
Mu/(Vud)= 0.544
k= 8.203
fVc= 1138.84 kips
Vu/f Vc= 0.657
(continued)

29 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 7.96 CY

Short Steel Bar Summary:


14 Total #10 Bars of length 7.243 ft (per bar)
28 Total Hooks of length 1.557 ft (per bar)
Weight = 624.9 lbs
Long Steel Bar Summary:
14 Total #10 Bars of length 7.243 ft (per bar)
28 Total Hooks of length 1.557 ft (per bar)
Weight = 624.9 lbs

Total weight of all steel = 1249.8 lbs or 0.625 tons

Comments:

30 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

31 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

6 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 4 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 120 tons
Pile Allowable Load (ASD) = 240 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 12 in. shown above. Actual dimensions
Pile Spacing, L= 3 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 21 in.
Pile Cap Dmin,recommended= 35 in.
Pile Cap Dcap= 48 in.
Pile Cap Dimension A= 9.5 ft.
Pile Cap Dimension B= 6.5 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 37.095 in.
Reinf. Effective dlong bars = 38.365 in.
Reinf. Effective dshear checks = 38 in.

Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NG CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2244.72 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 23.689 in.
Rounded Dimension c= 24 in.
(continued)

33 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 16866.18 k-in. Total moment on pile cap with offset
Mu= 1775.39 k-in./ft 1 ft strip design
d= 37.095 in.
As,required,structural,per ft= 0.914 in2/ft
As,required,structural,total= 8.686 in2
(4/3)As,required,structural,total= 11.581 in2
1/2
As,min,1=3(f'c) bwd/fy= 13.373 in2
As,min,2=200bwd/fy= 14.096 in2
As,min,1 or 2, controlling= 14.096 in2
As,min,3=(0.0018 or 0.002)Ag= 9.850 in2
As,required=
11.581 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.462
gs= 0.8125 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 10.315 in2
As,required= 11.581 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 16.868 in. OK; sufficient length available to develop hook
Req. number of short bars = 9.14
Prov. number of short bars = 13

Required Flexural Reinforcement - Long Bars


Mu= 24667.74 k-in. Total moment on pile cap with offset
Mu= 3795.04 k-in./ft 1 ft strip design
d= 38.365 in.
As,required,structural,per ft= 1.914 in2/ft
As,required,structural,total= 12.444 in2
(4/3)As,required,structural,total= 16.592 in2
As,min,1=3(f'c)1/2bwd/fy= 9.463 in2
As,min,2=200bwd/fy= 9.975 in2
As,min,1 or 2, controlling= 9.975 in2
As,min,3=(0.0018 or 0.002)Ag= 6.739 in2
As,required= 12.444 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 16.868 in. OK; sufficient length available to develop hook
Req. number of long bars = 9.82
Prov. number of long bars = 15

34 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

35 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38 in.
d/2= 19 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 252.98 psi
b0= 248 in.
Vc= 2384.10 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2026.49 kips
Vu= 1502.35 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.741

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 2964.00 in2
Vc= 374.92 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 318.68 kips
Vu= -3.64 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.011

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 4332.00 in2
Vc= 547.96 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 465.77 kips
Vu= 8.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.018

(continued)

36 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 38 in.

d/2= 19 in.

No. of piles outside face of the column = 6


wactual= 9.000 in. < d/2 This procedure applies
Vu= 2248.56 kips
0.5
4(fc') = 252.98 psi
0.5
32(fc') = 2023.86 psi
b0= 248.000 in.
bs= 96.000 in.
k= 21.815 based on k=2(d/w)(1+d/c) acting at column face
Vc= 5033.11 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 4278.14 kips
Vu/f Vc= 0.526 ****COMBINED**** Vu/f Vc= 1.051

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.365 in.
w'= 27.000 in.
w'/d= 0.704 OK, this limit state should be checked
Vu= 744.60 kips
Mu= 20209.50 k-in.
Vud/Mu= 1.414
Mu/(Vud)= 0.707
k= 5.022
fVc= 807.90 kips
Vu/f Vc= 0.922

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 37.095 in.
w'= 9 in.
w'/d= 0.243 OK, this limit state should be checked
Vu= 1131.48 kips
Mu= 10090.98 k-in.
Vud/Mu= 4.159
Mu/(Vud)= 0.240
k= 10.000
fVc= 2273.36 kips
Vu/f Vc= 0.498

37 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

38 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 9.15 CY

Short Steel Bar Summary:


13 Total #10 Bars of length 6.000 ft (per bar)
26 Total Hooks of length 1.557 ft (per bar)
Weight = 510.7 lbs
Long Steel Bar Summary:
15 Total #10 Bars of length 9.000 ft (per bar)
30 Total Hooks of length 1.557 ft (per bar)
Weight = 783.2 lbs

Total weight of all steel = 1293.8 lbs or 0.647 tons

Comments:

39 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

40 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

7 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 400 tons
Pile Allowable Load (ASD) = 800 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions
Pile Spacing, L= 5 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 36 in.
Pile Cap Dmin,recommended= 77 in.
Pile Cap Dcap= 84 in.
Pile Cap Dimension A= 16 ft.
Pile Cap Dimension B= 14.661 ft.
Short Bars Size (No.) = 14
Long Bars Size (No.) = 14
Reinf. Effective dshort bars = 72.461 in.
Reinf. Effective dlong bars = 74.154 in.
Reinf. Effective dshear checks = 74 in.
High capacity pile selected - special details required - see CRSI Pile Cap Design Guide
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NG CRSI Limit State P3 Adequate? NA
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 8565.91 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 52.217 in.
Rounded Dimension c= 53 in. DIAMETER FOR 7 PILE CAP
(continued)

41 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 100540.58 k-in. Total moment on pile cap with offset
Mu= 6283.79 k-in./ft 1 ft strip design
d= 72.461 in.
As,required,structural,per ft= 1.651 in2/ft
As,required,structural,total= 26.414 in2
(4/3)As,required,structural,total= 35.218 in2
1/2
As,min,1=3(f'c) bwd/fy= 38.101 in2
As,min,2=200bwd/fy= 46.375 in2
As,min,1 or 2, controlling= 46.375 in2
As,min,3=(0.0018 or 0.002)Ag= 29.030 in2
As,required=
35.218 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.091
gs= 0.9563289 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 27.567 in2
As,required= 35.218 in2
E'=E-Offset = 33 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of short bars = 15.65
Prov. number of short bars = 11

Required Flexural Reinforcement - Long Bars


Mu= 107212.55 k-in. Total moment on pile cap with offset
Mu= 7312.77 k-in./ft 1 ft strip design
d= 74.1535 in.
As,required,structural,per ft= 1.881 in2/ft
As,required,structural,total= 27.583 in2
(4/3)As,required,structural,total= 36.777 in2
As,min,1=3(f'c)1/2bwd/fy= 35.728 in2
As,min,2=200bwd/fy= 43.487 in2
As,min,1 or 2, controlling= 43.487 in2
As,min,3=(0.0018 or 0.002)Ag= 26.601 in2
As,required= 36.777 in2
E'=E-Offset = 33 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of long bars = 16.34
Prov. number of long bars = 11

42 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

43 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 74 in.
d/2= 37 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 219.09 psi
b0= 398.98193 in.
Vc= 6468.53 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 5498.25 kips
Vu= -246.30 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.045

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 74 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 13018.97 in2
Vc= 1426.16 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1212.23 kips
Vu= 9.24 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.008

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 74 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 14208.00 in2
Vc= 1556.41 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1322.95 kips
Vu= 28.08 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.021

(continued)

44 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 74 in.
d/2= 37 in.
No. of piles outside face of the column = 6
wactual= 36.500 in. < d/2 This procedure applies
Vu= 7318.68 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 398.971 in.
bs= 166.500 in.
k= 9.716 based on k=2(d/w)(1+d/c) acting at column face
Vc= 6556.95 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 5573.41 kips
Vu/f Vc= 1.313

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 74.1535 in.
w'= 6.500 in.
w'/d= 0.088 OK, this limit state should be checked
Vu= 3697.35 kips
Mu= 58402.86 k-in.
Vud/Mu= 4.694
Mu/(Vud)= 0.213
k= 10.000
fVc= 6073.74 kips
Vu/f Vc= 0.609

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 72.4605 in.
w'= 28.466 in.
w'/d= 0.393 OK, this limit state should be checked
Vu= 2422.32 kips
Mu= 68641.52 k-in.
Vud/Mu= 2.557
Mu/(Vud)= 0.391
k= 10.000
fVc= 6477.12 kips
Vu/f Vc= 0.374
(continued)

45 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 60.82 CY

Short Steel Bar Summary:


11 Total #14 Bars of length 14.161 ft (per bar)
22 Total Hooks of length 2.075 ft (per bar)
Weight = 1542.9 lbs
Long Steel Bar Summary:
11 Total #14 Bars of length 15.500 ft (per bar)
22 Total Hooks of length 2.075 ft (per bar)
Weight = 1655.7 lbs

Total weight of all steel = 3198.6 lbs or 1.599 tons

Comments:

46 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

47 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

8 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 120 tons
Pile Allowable Load (ASD) = 240 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 12 in. Note: Minimum cap dimensions
Pile Spacing, L= 3 shown above. Actual dimensions
ft.
provided to the left referencing
Pile Edge Distance, E= 21 in. figure below.
Pile Cap Dmin,recommended= 35 in.
Pile Cap Dcap= 51 in.
Pile Cap Dimension A= 9.5 ft.
Pile Cap Dimension B= 8.6966 ft.
Short Bars Size (No.) = 9
Long Bars Size (No.) = 8
Reinf. Effective dshort bars = 40.436 in.
Reinf. Effective dlong bars = 41.500 in.
Reinf. Effective dshear checks = 41 in.

Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2987.73 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 27.330 in.
Rounded Dimension c= 28 in.
(continued)

49 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 30482.62 k-in. Total moment on pile cap with offset
Mu= 3208.70 k-in./ft 1 ft strip design
d= 40.436 in.
As,required,structural,per ft= 1.531 in2/ft
As,required,structural,total= 14.546 in2
(4/3)As,required,structural,total= 19.395 in2
1/2
As,min,1=3(f'c) bwd/fy= 12.624 in2
As,min,2=200bwd/fy= 15.366 in2
As,min,1 or 2, controlling= 15.366 in2
As,min,3=(0.0018 or 0.002)Ag= 10.465 in2
As,required=
15.366 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.092
gs= 0.9558489 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 15.188 in2
As,required= 15.366 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 17.299 in. OK; sufficient length available to develop hook
Req. number of short bars = 15.38
Prov. number of short bars = 11

Required Flexural Reinforcement - Long Bars


Mu= 29027.99 k-in. Total moment on pile cap with offset
Mu= 3337.85 k-in./ft 1 ft strip design
d= 41.5 in.
As,required,structural,per ft= 1.551 in2/ft
As,required,structural,total= 13.491 in2
(4/3)As,required,structural,total= 17.987 in2
As,min,1=3(f'c)1/2bwd/fy= 11.861 in2
As,min,2=200bwd/fy= 14.436 in2
As,min,1 or 2, controlling= 14.436 in2
As,min,3=(0.0018 or 0.002)Ag= 9.580 in2
As,required= 14.436 in2
E'=E-Offset = 18 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 15.336 in. OK; sufficient length available to develop hook
Req. number of long bars = 18.38
Prov. number of long bars = 14

50 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

51 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 41 in.
d/2= 20.5 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 219.09 psi
b0= 276 in.
Vc= 2479.21 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2107.33 kips
Vu= 1485.45 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.705

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 41 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 4278.73 in2
Vc= 468.71 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 398.40 kips
Vu= -1.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.004

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 41 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 4674.00 in2
Vc= 512.01 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 435.21 kips
Vu= 2.28 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.005

(continued)

52 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 41 in.

d/2= 20.5 in.

No. of piles outside face of the column = 8


wactual= 7.000 in. < d/2 This procedure applies
Vu= 2993.28 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 276.000 in.
bs= 112.000 in.
k= 28.867 based on k=2(d/w)(1+d/c) acting at column face
Vc= 7260.55 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 6171.47 kips
Vu/f Vc= 0.485 ****COMBINED**** Vu/f Vc= 0.941

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 41.5 in.
w'= 7.000 in.
w'/d= 0.169 OK, this limit state should be checked
Vu= 1120.21 kips
Mu= 21204.60 k-in.
Vud/Mu= 2.192
Mu/(Vud)= 0.456
k= 10.000
fVc= 2016.32 kips
Vu/f Vc= 0.556

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 40.436 in.
w'= 20.176 in.
w'/d= 0.499 OK, this limit state should be checked
Vu= 1121.17 kips
Mu= 22654.21 k-in.
Vud/Mu= 2.001
Mu/(Vud)= 0.500
k= 9.473
fVc= 2033.09 kips
Vu/f Vc= 0.551

53 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

54 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 13.00 CY

Short Steel Bar Summary:


11 Total #9 Bars of length 8.197 ft (per bar)
22 Total Hooks of length 1.383 ft (per bar)
Weight = 410.0 lbs
Long Steel Bar Summary:
14 Total #8 Bars of length 9.000 ft (per bar)
28 Total Hooks of length 1.047 ft (per bar)
Weight = 415.1 lbs

Total weight of all steel = 825.1 lbs or 0.413 tons

Comments:

55 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

56 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

9 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Pile Type = Steel ###
Pile Shape = Round Bar No.
Concrete Comp. Strength, f'c= 3 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 400 tons ###
Pile Allowable Load (ASD) = 800 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 20 in. shown above. Actual dimensions ###
Pile Spacing, L= 5 ft. provided to the left referencing ###
figure below.
Pile Edge Distance, E= 36 in. ###
Pile Cap Dmin,recommended= 77 in. Short hook
Pile Cap Dcap= 90 in. Long hook a
Pile Cap Dimension A= 16 ft. Short Bar D
Pile Cap Dimension B= 16 ft. Short Bar Ar
Short Bars Size (No.) = 14 Steel pile em
Long Bars Size (No.) = 14
Reinf. Effective dshort bars = 78.461 in.
Reinf. Effective dlong bars = 80.154 in.
Reinf. Effective dshear checks = 80 in. If given pile
High capacity pile selected - special details required - see CRSI Pile Cap Design Guide
Design Checks: Equivalent P
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK d=
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK d/2=
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK Diameter fo
CRSI Limit State 4 Adequate? NG CRSI Limit State P3 Adequate? OK Area in shea
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NG 4(fc')0.5=
CRSI Limit State 6 Adequate? OK Vc=
Results:
Column Size Determination Vu=
Net Column Capacity Pu= 11059.20 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 52.581 in.
Rounded Dimension c= 53 in.
(continued)

57 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 182822.93 k-in. Total moment on pile cap with offset
Mu= 11426.43 k-in./ft 1 ft strip design
d= 78.461 in.
As,required,structural,per ft= 2.804 in2/ft
As,required,structural,total= 44.871 in2
(4/3)As,required,structural,total= 59.828 in2
1/2
As,min,1=3(f'c) bwd/fy= 41.256 in2
As,min,2=200bwd/fy= 50.215 in2
As,min,1 or 2, controlling= 50.215 in2
As,min,3=(0.0018 or 0.002)Ag= 31.104 in2
As,required=
50.215 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
gs= 1 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 44.871 in2
As,required= 50.215 in2
E'=E-Offset = 33 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of short bars = 22.31
Prov. number of short bars = 18

Required Flexural Reinforcement - Long Bars


Mu= 182822.93 k-in. Total moment on pile cap with offset
Mu= 11426.43 k-in./ft 1 ft strip design
d= 80.1535 in.
As,required,structural,per ft= 2.741 in2/ft
As,required,structural,total= 43.860 in2
(4/3)As,required,structural,total= 58.480 in2
As,min,1=3(f'c)1/2bwd/fy= 42.146 in2
As,min,2=200bwd/fy= 51.298 in2
As,min,1 or 2, controlling= 51.298 in2
As,min,3=(0.0018 or 0.002)Ag= 31.104 in2
As,required= 51.298 in2
E'=E-Offset = 33 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of long bars = 22.79
Prov. number of long bars = 18

58 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

59 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 80 in. distance fro
d/2= 40 in. distance fro
No. of piles outside d/2 from face of the column = 0 distance fro
4(fc')0.5= 219.09 psi
b0= 532 in.
Vc= 9324.43 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face Limit State A
fVc= 7925.76 kips
Vu= -239.69 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.030

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 80 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi
bd= 15360.00 in2 Limit State A
0.5
Vc= 1682.60 kips based on Vc=2(fc') bd acting at d from column face
fVc= 1430.21 kips
Vu= 25.20 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.018

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 80 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi
bd= 15360.00 in2 Limit State A
0.5
Vc= 1682.60 kips based on Vc=2(fc') bd acting at d from column face
fVc= 1430.21 kips
Vu= 25.20 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.018

(continued)

60 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 80 in.
d/2= 40 in.
No. of piles outside face of the column = 8
wactual= 36.500 in. < d/2 This procedure applies
Vu= 9814.31 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 532.000 in.
bs= 212.000 in. Limit State A
k= 11.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 10218.55 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 8685.77 kips
Vu/f Vc= 1.130

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 80.1535 in.
w'= 36.500 in.
w'/d= 0.455 OK, this limit state should be checked
Vu= 3673.20 kips
Mu= 134363.70 k-in.
Vud/Mu= 2.191 Limit State A
Mu/(Vud)= 0.456
k= 10.000
fVc= 7164.79 kips
Vu/f Vc= 0.513

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 78.4605 in.
w'= 36.5 in.
w'/d= 0.465 OK, this limit state should be checked
Vu= 3673.20 kips
Mu= 134363.70 k-in.
Vud/Mu= 2.145 Limit State A
Mu/(Vud)= 0.466
k= 10.000
fVc= 7013.45 kips
Vu/f Vc= 0.524
(continued)

61 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary: d=
Quantity = 71.11 CY d/2=
Diameter fo
Short Steel Bar Summary: Area in shea
18 Total #14 Bars of length 15.500 ft (per bar) 4(fc')0.5=
36 Total Hooks of length 2.075 ft (per bar) Vc=
Weight = 2709.3 lbs
Long Steel Bar Summary: Vu=
18 Total #14 Bars of length 15.500 ft (per bar)
36 Total Hooks of length 2.075 ft (per bar)
Weight = 2709.3 lbs
d=
Total weight of all steel = 5418.6 lbs or 2.709 tons d/2=
Straight dim
Round dime
Comments: Area in shea
4(fc')0.5=
Vc=

Vu=

d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=

Vu=
Vu/f Vc=

d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=

62 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Vc=

63 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

10 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 400 tons
Pile Allowable Load (ASD) = 800 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 20 in.
Note: Minimum cap dimensions
shown above. Actual dimensions
Pile Spacing, L= 5 ft. provided to the left referencing
Pile Edge Distance, E= 36 in. figure below.
Pile Cap Dmin,recommended= 77 in.
Pile Cap Dcap= 81 in.
Pile Cap Dimension A= 21 ft.
Pile Cap Dimension B= 14.661 ft.
Short Bars Size (No.) = 14
Long Bars Size (No.) = 14
Reinf. Effective dshort bars = 69.461 in.
Reinf. Effective dlong bars = 71.154 in.
Reinf. Effective dshear checks = 71 in.
High capacity pile selected - special details required - see CRSI Pile Cap Design Guide
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop straight bars? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 12301.23 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 55.455 in.
Rounded Dimension c= 56 in.
(continued)

65 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 149531.30 k-in. Total moment on pile cap with offset
Mu= 7120.54 k-in./ft 1 ft strip design
d= 69.461 in.
As,required,structural,per ft= 1.961 in2/ft
As,required,structural,total= 41.172 in2
(4/3)As,required,structural,total= 54.895 in2
1/2
As,min,1=3(f'c) bwd/fy= 47.937 in2
As,min,2=200bwd/fy= 58.347 in2
As,min,1 or 2, controlling= 58.347 in2
As,min,3=(0.0018 or 0.002)Ag= 36.742 in2
As,required=
54.895 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.432
gs= 0.8222428 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 48.490 in2
As,required= 54.895 in2
E'=E-Offset = 33 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 25.964 in. OK; sufficient length available to develop hook
Req. number of short bars = 24.39
Prov. number of short bars = 21

Required Flexural Reinforcement - Long Bars


Mu= 238466.24 k-in. Total moment on pile cap with offset
Mu= 16265.35 k-in./ft 1 ft strip design
d= 71.1535 in.
As,required,structural,per ft= 4.525 in2/ft
As,required,structural,total= 66.338 in2
(4/3)As,required,structural,total= 88.451 in2
As,min,1=3(f'c)1/2bwd/fy= 34.282 in2
As,min,2=200bwd/fy= 41.727 in2
As,min,1 or 2, controlling= 41.727 in2
As,min,3=(0.0018 or 0.002)Ag= 25.651 in2
As,required= 66.338 in2
cb= 3.505 in.
ld= 67.186 in.
lavailable= 95.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 29.47
Prov. number of long bars = 25

66 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

67 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 71 in.
d/2= 35.5 in.
No. of piles outside d/2 from face of the column = 2
4(fc')0.5= 219.09 psi
b0= 508 in.
Vc= 7902.10 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 6716.79 kips
Vu= 2242.68 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.334

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 71 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 12491.17 in2
Vc= 1368.34 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1163.09 kips
Vu= -53.44 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.046

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 71 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 17892.00 in2
Vc= 1959.97 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1665.97 kips
Vu= 31.28 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.019

(continued)

68 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 71 in.

d/2= 35.5 in.

No. of piles outside face of the column = 10


wactual= 5.000 in. < d/2 This procedure applies
Vu= 12336.51 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 508.000 in.
bs= 224.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 27875.13 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 23693.86 kips
Vu/f Vc= 0.521 ****COMBINED**** Vu/f Vc= 0.674

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 71.1535 in.
w'= 5.000 in.
w'/d= 0.070 OK, this limit state should be checked
Vu= 4926.03 kips
Mu= 169695.71 k-in.
Vud/Mu= 2.065
Mu/(Vud)= 0.484
k= 10.000
fVc= 5828.01 kips
Vu/f Vc= 0.845

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 69.4605 in.
w'= 26.96 in.
w'/d= 0.388 OK, this limit state should be checked
Vu= 3670.00 kips
Mu= 98429.18 k-in.
Vud/Mu= 2.590
Mu/(Vud)= 0.386
k= 10.000
fVc= 8149.26 kips
Vu/f Vc= 0.450

69 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

70 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 76.97 CY

Short Steel Bar Summary:


21 Total #14 Bars of length 14.161 ft (per bar)
42 Total Hooks of length 2.075 ft (per bar)
Weight = 2945.5 lbs
Long Steel Bar Summary:
25 Total #14 Bars of length 20.500 ft (per bar)
0 Total Hooks of length 2.075 ft (per bar)
Weight = 3925.7 lbs

Total weight of all steel = 6871.2 lbs or 3.436 tons

Comments:

71 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

72 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

11 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 160 tons
Pile Allowable Load (ASD) = 320 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 15 in. Note: Minimum cap dimensions
Pile Spacing, L= 3.75 ft. shown above. Actual dimensions
provided to the left referencing
Pile Edge Distance, E= 27 in. figure below.
Pile Cap Dmin,recommended= 41 in.
Pile Cap Dcap= 63 in.
Pile Cap Dimension A= 15.75 ft.
Pile Cap Dimension B= 10.99575 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 51.885 in.
Reinf. Effective dlong bars = 53.295 in.
Reinf. Effective dshear checks = 53 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5413.79 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 36.789 in.
Rounded Dimension c= 37 in.
(continued)

73 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 64359.17 k-in. Total moment on pile cap with offset
Mu= 4086.30 k-in./ft 1 ft strip design
d= 51.885 in.
As,required,structural,per ft= 1.507 in2/ft
As,required,structural,total= 23.741 in2
(4/3)As,required,structural,total= 31.654 in2
1/2
As,min,1=3(f'c) bwd/fy= 26.856 in2
As,min,2=200bwd/fy= 32.688 in2
As,min,1 or 2, controlling= 32.688 in2
As,min,3=(0.0018 or 0.002)Ag= 21.433 in2
As,required=
31.654 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.432
gs= 0.8222428 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 27.961 in2
As,required= 31.654 in2
E'=E-Offset = 24 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 21.624 in. OK; sufficient length available to develop hook
Req. number of short bars = 20.27
Prov. number of short bars = 20

Required Flexural Reinforcement - Long Bars


Mu= 95004.60 k-in. Total moment on pile cap with offset
Mu= 8640.12 k-in./ft 1 ft strip design
d= 53.295 in.
As,required,structural,per ft= 3.197 in2/ft
As,required,structural,total= 35.156 in2
(4/3)As,required,structural,total= 46.875 in2
As,min,1=3(f'c)1/2bwd/fy= 19.259 in2
As,min,2=200bwd/fy= 23.441 in2
As,min,1 or 2, controlling= 23.441 in2
As,min,3=(0.0018 or 0.002)Ag= 14.963 in2
As,required= 35.156 in2
cb= 2.965 in.
ld= 55.085 in.
lavailable= 73.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 22.52
Prov. number of long bars = 22

74 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

75 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 53 in.
d/2= 26.5 in.
No. of piles outside d/2 from face of the column = 6
4(fc')0.5= 219.09 psi
b0= 360 in.
Vc= 4180.22 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3553.19 kips
Vu= 2924.66 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.823

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 53 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 6993.30 in2
Vc= 766.08 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 651.17 kips
Vu= -26.55 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.041

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 53 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 10017.00 in2
Vc= 1097.31 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 932.71 kips
Vu= 9.14 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.010

(continued)

76 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 53 in.

d/2= 26.5 in.

No. of piles outside face of the column = 10


wactual= 7.000 in. < d/2 This procedure applies
Vu= 4913.77 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 360.000 in.
bs= 148.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 13748.27 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 11686.03 kips
Vu/f Vc= 0.420 ****COMBINED**** Vu/f Vc= 0.823

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 53.295 in.
w'= 7.000 in.
w'/d= 0.131 OK, this limit state should be checked
Vu= 2472.25 kips
Mu= 72185.65 k-in.
Vud/Mu= 1.825
Mu/(Vud)= 0.548
k= 10.000
fVc= 3273.95 kips
Vu/f Vc= 0.755

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 51.885 in.
w'= 23.4745 in.
w'/d= 0.452 OK, this limit state should be checked
Vu= 1969.49 kips
Mu= 46212.14 k-in.
Vud/Mu= 2.211
Mu/(Vud)= 0.452
k= 10.000
fVc= 4565.45 kips
Vu/f Vc= 0.431

77 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

(continued)

78 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 33.67 CY

Short Steel Bar Summary:


20 Total #11 Bars of length 10.496 ft (per bar)
40 Total Hooks of length 1.728 ft (per bar)
Weight = 1482.6 lbs
Long Steel Bar Summary:
22 Total #11 Bars of length 15.250 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1782.5 lbs

Total weight of all steel = 3265.1 lbs or 1.633 tons

Comments:

79 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

80 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

12 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 8 in.
Note: Minimum cap dimensions
Pile Spacing, L= 3 ft. shown above. Actual dimensions
Pile Edge Distance, E= 15 in. provided to the left referencing
Pile Cap Dmin,recommended= figure below.
23 in.
Pile Cap Dcap= 48 in.
Pile Cap Dimension A= 11.5 ft.
Pile Cap Dimension B= 8.5 ft.
Short Bars Size (No.) = 6
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 37.355 in.
Reinf. Effective dlong bars = 38.365 in.
Reinf. Effective dshear checks = 38 in.

Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? NG CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1442.16 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 18.988 in.
Rounded Dimension c= 19 in.
(continued)

81 of 206 09/13/2020 12:28:16


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 16552.03 k-in. Total moment on pile cap with offset
Mu= 1439.31 k-in./ft 1 ft strip design
d= 37.355 in.
As,required,structural,per ft= 0.732 in2/ft
As,required,structural,total= 8.414 in2
(4/3)As,required,structural,total= 11.219 in2
1/2
As,min,1=3(f'c) bwd/fy= 14.118 in2
As,min,2=200bwd/fy= 17.183 in2
As,min,1 or 2, controlling= 17.183 in2
As,min,3=(0.0018 or 0.002)Ag= 11.923 in2
As,required=
11.923 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.353
gs= 0.85 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 9.676 in2
As,required= 11.923 in2
E'=E-Offset = 12 in. Available for hook as past pile edge
ye= 1 Use 1.0 for no epoxy coating
ldh= 11.502 in. OK; sufficient length available to develop hook
Req. number of short bars = 26.99
Prov. number of short bars = 31

Required Flexural Reinforcement - Long Bars


Mu= 24900.46 k-in. Total moment on pile cap with offset
Mu= 2929.47 k-in./ft 1 ft strip design
d= 38.365 in.
As,required,structural,per ft= 1.474 in2/ft
As,required,structural,total= 12.530 in2
(4/3)As,required,structural,total= 16.707 in2
As,min,1=3(f'c)1/2bwd/fy= 10.717 in2
As,min,2=200bwd/fy= 13.044 in2
As,min,1 or 2, controlling= 13.044 in2
As,min,3=(0.0018 or 0.002)Ag= 8.813 in2
As,required= 13.044 in2
cb= 3.158 in.
ld= 41.966 in.
lavailable= 56.500 in. OK; sufficient length available to develop bar
Req. number of long bars = 10.30
Prov. number of long bars = 16

82 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

83 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38 in.
d/2= 19 in.
No. of piles outside d/2 from face of the column = 10
4(fc')0.5= 219.09 psi
b0= 228 in.
Vc= 1898.19 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1613.46 kips
Vu= 1207.82 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.749

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 109.54 psi
bd= 3876.00 in2
Vc= 424.59 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 360.91 kips
Vu= 369.38 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 1.023

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 5244.00 in2
Vc= 574.45 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 488.28 kips
Vu= -3.22 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.007

(continued)

84 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 38 in.

d/2= 19 in.

No. of piles outside face of the column = 12


wactual= 11.500 in. < d/2 This procedure applies
Vu= 1444.57 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 228.000 in.
bs= 76.000 in.
k= 19.826 based on k=2(d/w)(1+d/c) acting at column face
Vc= 3136.14 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 2665.72 kips
Vu/f Vc= 0.542 ****COMBINED**** Vu/f Vc= 0.966

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.365 in.
w'= 11.500 in.
w'/d= 0.300 OK, this limit state should be checked
Vu= 727.54 kips
Mu= 21452.32 k-in.
Vud/Mu= 1.301
Mu/(Vud)= 0.769
k= 10.000
fVc= 1821.86 kips
Vu/f Vc= 0.399

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 37.355 in.
w'= 29.5 in.
w'/d= 0.790 OK, this limit state should be checked
Vu= 473.82 kips
Mu= 14311.77 k-in.
Vud/Mu= 1.237
Mu/(Vud)= 0.809
k= 3.789
fVc= 909.28 kips
Vu/f Vc= 0.521

85 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

86 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 14.48 CY

Short Steel Bar Summary:


31 Total #6 Bars of length 8.000 ft (per bar)
62 Total Hooks of length 0.785 ft (per bar)
Weight = 446.0 lbs
Long Steel Bar Summary:
16 Total #10 Bars of length 11.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 758.6 lbs

Total weight of all steel = 1204.6 lbs or 0.602 tons

Comments:

87 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

88 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

13 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 120 tons
Pile Allowable Load (ASD) = 240 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 12 in. Note: Minimum cap dimensions
shown above. Actual dimensions
Pile Spacing, L= 3 ft.
provided to the left referencing
Pile Edge Distance, E= 21 in. figure below.
Pile Cap Dmin,recommended= 35 in.
Pile Cap Dcap= 58 in.
Pile Cap Dimension A= 13.892 ft.
Pile Cap Dimension B= 9.5 ft.
Short Bars Size (No.) = 8
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 47.230 in.
Reinf. Effective dlong bars = 48.365 in.
Reinf. Effective dshear checks = 48 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 4838.91 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 34.781 in.
Rounded Dimension c= 35 in.
(continued)

89 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 42692.83 k-in. Total moment on pile cap with offset
Mu= 3073.20 k-in./ft 1 ft strip design
d= 47.230 in.
As,required,structural,per ft= 1.242 in2/ft
As,required,structural,total= 17.259 in2
(4/3)As,required,structural,total= 23.012 in2
1/2
As,min,1=3(f'c) bwd/fy= 21.562 in2
As,min,2=200bwd/fy= 26.245 in2
As,min,1 or 2, controlling= 26.245 in2
As,min,3=(0.0018 or 0.002)Ag= 17.404 in2
As,required=
23.012 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.462
gs= 0.8122435 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 20.499 in2
As,required= 23.012 in2
cb= 3 in.
ld= 32.863 in.
lavailable= 36.500 in. OK; sufficient length available to develop bar
Req. number of short bars = 29.30
Prov. number of short bars = 29

Required Flexural Reinforcement - Long Bars


Mu= 82177.20 k-in. Total moment on pile cap with offset
Mu= 8650.23 k-in./ft 1 ft strip design
d= 48.365 in.
As,required,structural,per ft= 3.578 in2/ft
As,required,structural,total= 33.994 in2
(4/3)As,required,structural,total= 45.326 in2
As,min,1=3(f'c)1/2bwd/fy= 15.100 in2
As,min,2=200bwd/fy= 18.379 in2
As,min,1 or 2, controlling= 18.379 in2
As,min,3=(0.0018 or 0.002)Ag= 11.902 in2
As,required= 33.994 in2
cb= 2.135 in.
ld= 62.079 in.
lavailable= 62.852 in. OK; sufficient length available to develop bar
Req. number of long bars = 26.84
Prov. number of long bars = 26

90 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

91 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48 in.
d/2= 24 in.
No. of piles outside d/2 from face of the column = 6
4(fc')0.5= 219.09 psi
b0= 332 in.
Vc= 3491.40 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2967.69 kips
Vu= 2206.40 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.743

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 5472.00 in2
Vc= 599.43 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 509.51 kips
Vu= -16.39 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.032

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 8001.79 in2
Vc= 876.55 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 745.07 kips
Vu= 11.41 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.015

(continued)

92 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 48 in.

d/2= 24 in.

No. of piles outside face of the column = 12


wactual= 3.500 in. < d/2 This procedure applies
Vu= 4464.78 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 332.000 in.
bs= 140.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 11778.23 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 10011.49 kips
Vu/f Vc= 0.446 ****COMBINED**** Vu/f Vc= 0.746

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.365 in.
w'= 16.676 in.
w'/d= 0.345 OK, this limit state should be checked
Vu= 1859.53 kips
Mu= 65941.50 k-in.
Vud/Mu= 1.364
Mu/(Vud)= 0.733
k= 9.845
fVc= 2527.25 kips
Vu/f Vc= 0.736

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.23 in.
w'= 3.5 in.
w'/d= 0.074 OK, this limit state should be checked
Vu= 1866.96 kips
Mu= 26408.38 k-in.
Vud/Mu= 3.339
Mu/(Vud)= 0.299
k= 10.000
fVc= 3665.59 kips
Vu/f Vc= 0.509

93 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

94 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 23.62 CY

Short Steel Bar Summary:


29 Total #8 Bars of length 9.000 ft (per bar)
0 Total Hooks of length 1.047 ft (per bar)
Weight = 697.5 lbs
Long Steel Bar Summary:
26 Total #10 Bars of length 13.392 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 1500.8 lbs

Total weight of all steel = 2198.4 lbs or 1.099 tons

Comments:

95 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

96 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

14 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Pile Type = Steel ###
Pile Shape = Round Bar No.
Concrete Comp. Strength, f'c= 3 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 140 tons ###
Pile Allowable Load (ASD) = 280 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Minimum Pile Dimension dp= 12 in. Note: Minimum cap dimensions ###
Pile Spacing, L= 3 shown above. Actual dimensions ###
ft.
provided to the left referencing
Pile Edge Distance, E= 27 in. figure below. ###
Pile Cap Dmin,recommended= 38 in. Short hook
Pile Cap Dcap= 70 in. Long hook a
Pile Cap Dimension A= 13.5 ft. Short Bar D
Pile Cap Dimension B= 12.696 ft. Short Bar Ar
Short Bars Size (No.) = 9 Steel pile em
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 59.166 in.
Reinf. Effective dlong bars = 60.365 in.
Reinf. Effective dshear checks = 60 in. If given pile

Design Checks: Equivalent P


Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? OK
CRSI Limit State 1 Adequate? OK d=
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK d/2=
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK Diameter fo
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK Area in shea
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA 4(fc')0.5=
CRSI Limit State 6 Adequate? OK Vc=
Results:
Column Size Determination Vu=
Net Column Capacity Pu= 6032.05 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 38.833 in.
Rounded Dimension c= 39 in.
(continued)

97 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 73705.77 k-in. Total moment on pile cap with offset
Mu= 5459.69 k-in./ft 1 ft strip design
d= 59.166 in.
As,required,structural,per ft= 1.767 in2/ft
As,required,structural,total= 23.860 in2
(4/3)As,required,structural,total= 31.813 in2
1/2
As,min,1=3(f'c) bwd/fy= 26.249 in2
As,min,2=200bwd/fy= 31.950 in2
As,min,1 or 2, controlling= 31.950 in2
As,min,3=(0.0018 or 0.002)Ag= 20.412 in2
As,required=
31.813 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.063
gs= 0.9693083 % steel concentrated of width B of long side A c. to c. spacing o
As,required,structural,total,modfied= 24.592 in2 concrete cover =
As,required= 31.813 in2 cb=

cb= 3 in.
ld= 40.499 in. yt=

lavailable= 53.676 in. OK; sufficient length available to develop bar ye =

Req. number of short bars = 31.84 ys =

Prov. number of short bars = 31 (cb+Ktr)/db=


l d=

Required Flexural Reinforcement - Long Bars lavailable=

Mu= 74864.30 k-in. Total moment on pile cap with offset


Mu= 5896.68 k-in./ft 1 ft strip design
d= 60.365 in.
As,required,structural,per ft= 1.873 in2/ft c. to c. spacing o
As,required,structural,total= 23.778 in2 concrete cover =
(4/3)As,required,structural,total= 31.705 in2 cb=

As,min,1=3(f'c)1/2bwd/fy= 25.186 in2


As,min,2=200bwd/fy= 30.656 in2 yt=

As,min,1 or 2, controlling= 30.656 in2 ye =

As,min,3=(0.0018 or 0.002)Ag= 19.196 in2 ys =

As,required= 30.656 in2 (cb+Ktr)/db=

cb= 3.154 in. l d=

ld= 42.015 in. lavailable=

lavailable= 58.500 in. OK; sufficient length available to develop bar


Req. number of long bars = 24.20
Prov. number of long bars = 24

98 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

99 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 60 in. distance fro
d/2= 30 in. distance fro
No. of piles outside d/2 from face of the column = 10 distance fro
4(fc')0.5= 219.09 psi distance fro
b0= 396 in. distance fro
0.5
Vc= 5205.56 kips based on Vc=4(fc') b0d acting at d/2 from column face distance fro
fVc= 4424.72 kips
Vu= 4335.33 kips reduced by weight of concrete outside of critical section Limit State A
Vu/f Vc= 0.980

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 60 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi distance fro
bd= 9141.12 in2 distance fro
Vc= 1001.36 kips based on Vc=2(fc')0.5bd acting at d from column face Limit State A
fVc= 851.16 kips
Vu= -2.22 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.003

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 60 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi distance fro
bd= 9720.00 in2 Limit State A
Vc= 1064.77 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 905.06 kips
Vu= 5.24 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.006

(continued)

100 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 60 in.
d/2= 30 in.
No. of piles outside face of the column = 14
wactual= 1.500 in. < d/2 This procedure applies
Vu= 6046.83 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 396.000 in.
bs= 156.000 in. Limit State A
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 16405.39 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 13944.58 kips
Vu/f Vc= 0.434

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 60.365 in.
w'= 1.500 in.
w'/d= 0.025 OK, this limit state should be checked
Vu= 2596.91 kips
Mu= 49614.87 k-in.
Vud/Mu= 3.160 Limit State A
Mu/(Vud)= 0.316
k= 10.000
fVc= 4281.67 kips
Vu/f Vc= 0.607

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 59.166 in.
w'= 1.5 in.
w'/d= 0.025 OK, this limit state should be checked
Vu= 3046.74 kips
Mu= 44607.18 k-in.
Vud/Mu= 4.041 Limit State A
Mu/(Vud)= 0.247
k= 10.000
fVc= 4462.38 kips
Vu/f Vc= 0.683
(continued)

101 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary: d=
Quantity = 37.03 CY d/2=
Diameter fo
Short Steel Bar Summary: Area in shea
31 Total #9 Bars of length 12.196 ft (per bar) 4(fc')0.5=
0 Total Hooks of length 1.383 ft (per bar) Vc=
Weight = 1285.6 lbs
Long Steel Bar Summary: Vu=
24 Total #10 Bars of length 13.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 1344.8 lbs
d=
Total weight of all steel = 2630.5 lbs or 1.315 tons d/2=
Straight dim
Round dime
Comments: Area in shea
4(fc')0.5=
Vc=

Vu=

d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=

Vu=
Vu/f Vc=

d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=

102 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Vc=

103 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

15 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 8 in. shown above. Actual dimensions
Pile Spacing, L= 3 ft. provided to the left referencing
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin,recommended= 23 in. A'= 5.867 ft.
Pile Cap Dcap= 48 in. B'= 7.444 ft.
Pile Cap Dimension A= 12.892 ft.
Pile Cap Dimension B= 11.5 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 36.885 in.
Reinf. Effective dlong bars = 38.295 in.
Reinf. Effective dshear checks = 38 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1791.35 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.162 in.
Rounded Dimension c= 22 in.
(continued)

105 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 28353.03 k-in. Total moment on pile cap with offset
Mu= 2199.27 k-in./ft 1 ft strip design
d= 36.885 in.
As,required,structural,per ft= 1.143 in2/ft
As,required,structural,total= 14.738 in2
(4/3)As,required,structural,total= 19.650 in2
1/2
As,min,1=3(f'c) bwd/fy= 15.627 in2
As,min,2=200bwd/fy= 19.021 in2
As,min,1 or 2, controlling= 19.021 in2
As,min,3=(0.0018 or 0.002)Ag= 13.366 in2
As,required=
19.021 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.121
gs= 0.9429321 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 15.579 in2
As,required= 19.021 in2
cb= 4 in.
ld= 46.337 in.
lavailable= 55.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 12.18
Prov. number of short bars = 17

Required Flexural Reinforcement - Long Bars


Mu= 28062.26 k-in. Total moment on pile cap with offset
Mu= 2440.20 k-in./ft 1 ft strip design
d= 38.295 in.
As,required,structural,per ft= 1.223 in2/ft
As,required,structural,total= 14.062 in2
(4/3)As,required,structural,total= 18.749 in2
As,min,1=3(f'c)1/2bwd/fy= 14.473 in2
As,min,2=200bwd/fy= 17.616 in2
As,min,1 or 2, controlling= 17.616 in2
As,min,3=(0.0018 or 0.002)Ag= 11.923 in2
As,required= 17.616 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 63.352 in. OK; sufficient length available to develop bar
Req. number of long bars = 11.28
Prov. number of long bars = 13

106 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

107 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38 in.
d/2= 19 in.
No. of piles outside d/2 from face of the column = 14
4(fc')0.5= 219.09 psi
b0= 240 in.
Vc= 1998.09 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1698.38 kips
Vu= 1687.35 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.994

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 4638.55 in2
Vc= 508.13 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 431.91 kips
Vu= 236.75 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.548

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 5308.00 in2
Vc= 581.46 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 494.24 kips
Vu= 242.21 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.490

(continued)

108 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 38 in.

d/2= 19 in.

No. of piles outside face of the column = 14


wactual= 10.000 in. < d/2 This procedure applies
Vu= 1666.58 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 240.000 in.
bs= 88.000 in.
k= 20.727 based on k=2(d/w)(1+d/c) acting at column face
Vc= 3796.37 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 3226.92 kips
Vu/f Vc= 0.516 ****COMBINED**** Vu/f Vc= 0.857

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.295 in.
w'= 23.176 in.
w'/d= 0.605 OK, this limit state should be checked
Vu= 713.79 kips
Mu= 24187.92 k-in.
Vud/Mu= 1.130
Mu/(Vud)= 0.885
k= 4.284
fVc= 1053.90 kips
Vu/f Vc= 0.677

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 36.885 in.
w'= 10 in.
w'/d= 0.271 OK, this limit state should be checked
Vu= 843.02 kips
Mu= 23769.63 k-in.
Vud/Mu= 1.308
Mu/(Vud)= 0.764
k= 10.000
fVc= 2656.63 kips
Vu/f Vc= 0.317

109 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

110 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 19.85 CY

Short Steel Bar Summary:


17 Total #11 Bars of length 11.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 993.6 lbs
Long Steel Bar Summary:
13 Total #11 Bars of length 12.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 855.9 lbs

Total weight of all steel = 1849.5 lbs or 0.925 tons

Comments:

111 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

112 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

16 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Pile Type = Steel ###
Pile Shape = Round Bar No.
Concrete Comp. Strength, f'c= 3 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 120 tons ###
Pile Allowable Load (ASD) = 240 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Minimum Pile Dimension dp= 12 in.
Note: Minimum cap dimensions ###
shown above. Actual dimensions
Pile Spacing, L= 3 ft. provided to the left referencing ###
Pile Edge Distance, E= 21 in. figure below. ###
Pile Cap Dmin,recommended= 35 in. Short hook
Pile Cap Dcap= 71 in. Long hook a
Pile Cap Dimension A= 12.5 ft. Short Bar D
Pile Cap Dimension B= 12.5 ft. Short Bar Ar
Short Bars Size (No.) = 9 Steel pile em
Long Bars Size (No.) = 9
Reinf. Effective dshort bars = 60.308 in.
Reinf. Effective dlong bars = 61.436 in.
Reinf. Effective dshear checks = 61 in. If given pile

Design Checks: Equivalent P


Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? OK
CRSI Limit State 1 Adequate? OK d=
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK d/2=
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK Diameter fo
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK Area in shea
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK 4(fc')0.5=
CRSI Limit State 6 Adequate? OK Vc=
Results:
Column Size Determination Vu=
Net Column Capacity Pu= 5922.13 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 38.478 in.
Rounded Dimension c= 39 in.
(continued)

113 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 86707.18 k-in. Total moment on pile cap with offset
Mu= 6936.57 k-in./ft 1 ft strip design
d= 60.308 in.
As,required,structural,per ft= 2.217 in2/ft
As,required,structural,total= 27.713 in2
(4/3)As,required,structural,total= 36.951 in2
1/2
As,min,1=3(f'c) bwd/fy= 24.774 in2
As,min,2=200bwd/fy= 30.154 in2
As,min,1 or 2, controlling= 30.154 in2
As,min,3=(0.0018 or 0.002)Ag= 19.170 in2
As,required=
30.154 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
gs= 1 % steel concentrated of width B of long side A c. to c. spacing o
As,required,structural,total,modfied= 27.713 in2 concrete cover =
As,required= 30.154 in2 cb=

cb= 2 in.
ld= 42.438 in. yt=

lavailable= 52.500 in. OK; sufficient length available to develop bar ye =

Req. number of short bars = 30.18 ys =

Prov. number of short bars = 30 (cb+Ktr)/db=


l d=

Required Flexural Reinforcement - Long Bars lavailable=

Mu= 86707.18 k-in. Total moment on pile cap with offset


Mu= 6936.57 k-in./ft 1 ft strip design
d= 61.436 in.
As,required,structural,per ft= 2.174 in2/ft c. to c. spacing o
As,required,structural,total= 27.169 in2 concrete cover =
(4/3)As,required,structural,total= 36.225 in2 cb=

As,min,1=3(f'c)1/2bwd/fy= 25.237 in2


As,min,2=200bwd/fy= 30.718 in2 yt=

As,min,1 or 2, controlling= 30.718 in2 ye =

As,min,3=(0.0018 or 0.002)Ag= 19.170 in2 ys =

As,required= 30.718 in2 (cb+Ktr)/db=

cb= 2.463 in. l d=

ld= 42.438 in. lavailable=

lavailable= 52.500 in. OK; sufficient length available to develop bar


Req. number of long bars = 30.74
Prov. number of long bars = 30

114 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

115 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 61 in. distance fro
d/2= 30.5 in. distance fro
No. of piles outside d/2 from face of the column = 12 distance fro
4(fc')0.5= 219.09 psi distance fro
b0= 400 in. distance fro
0.5
Vc= 5345.77 kips based on Vc=4(fc') b0d acting at d/2 from column face Limit State A
fVc= 4543.91 kips
Vu= 4484.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.987

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 61 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi distance fro
bd= 9150.00 in2 Limit State A
Vc= 1002.33 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 851.98 kips
Vu= 8.14 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.010

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 61 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi distance fro
bd= 9150.00 in2 Limit State A
Vc= 1002.33 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 851.98 kips
Vu= 8.14 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.010

(continued)

116 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 61 in.
d/2= 30.5 in.
No. of piles outside face of the column = 16
wactual= 1.500 in. < d/2 This procedure applies
Vu= 5937.12 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 400.000 in.
bs= 156.000 in. Limit State A
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 16678.81 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 14176.99 kips
Vu/f Vc= 0.419

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 61.436 in.
w'= 1.500 in.
w'/d= 0.024 OK, this limit state should be checked
Vu= 2989.91 kips
Mu= 57625.90 k-in.
Vud/Mu= 3.188 Limit State A
Mu/(Vud)= 0.314
k= 10.000
fVc= 4290.36 kips
Vu/f Vc= 0.697

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 60.308 in.
w'= 1.5 in.
w'/d= 0.025 OK, this limit state should be checked
Vu= 2989.91 kips
Mu= 57625.90 k-in.
Vud/Mu= 3.129 Limit State A
Mu/(Vud)= 0.320
k= 10.000
fVc= 4211.59 kips
Vu/f Vc= 0.710
(continued)

117 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary: d=
Quantity = 34.24 CY d/2=
Diameter fo
Short Steel Bar Summary: Area in shea
30 Total #9 Bars of length 12.000 ft (per bar) 4(fc')0.5=
0 Total Hooks of length 1.383 ft (per bar) Vc=
Weight = 1224.1 lbs
Long Steel Bar Summary: Vu=
30 Total #9 Bars of length 12.000 ft (per bar)
0 Total Hooks of length 1.383 ft (per bar)
Weight = 1224.1 lbs
d=
Total weight of all steel = 2448.3 lbs or 1.224 tons d/2=
Straight dim
Round dime
Comments: Area in shea
4(fc')0.5=
Vc=

Vu=

d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=

Vu=
Vu/f Vc=

d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=

118 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Vc=

119 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

17 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 8 in. shown above. Actual dimensions
Pile Spacing, L= 3 ft. provided to the left referencing
Pile Edge Distance, E= 15 figure below.
in.
Pile Cap Dmin,recommended= 23 in. A'= 5.867 ft.
Pile Cap Dcap= 51 in. B'= 7.444 ft.
Pile Cap Dimension A= 12.892 ft.
Pile Cap Dimension B= 11.5 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 39.955 in.
Reinf. Effective dlong bars = 41.295 in.
Reinf. Effective dshear checks = 41 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2039.31 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 22.579 in.
Rounded Dimension c= 23 in.
(continued)

121 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 28042.45 k-in. Total moment on pile cap with offset
Mu= 2175.18 k-in./ft 1 ft strip design
d= 39.955 in.
As,required,structural,per ft= 1.039 in2/ft
As,required,structural,total= 13.397 in2
(4/3)As,required,structural,total= 17.863 in2
1/2
As,min,1=3(f'c) bwd/fy= 16.928 in2
As,min,2=200bwd/fy= 20.604 in2
As,min,1 or 2, controlling= 20.604 in2
As,min,3=(0.0018 or 0.002)Ag= 14.202 in2
As,required=
17.863 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.121
gs= 0.9429321 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 14.162 in2
As,required= 17.863 in2
cb= 4 in.
ld= 41.736 in.
lavailable= 54.500 in. OK; sufficient length available to develop bar
Req. number of short bars = 14.10
Prov. number of short bars = 16

Required Flexural Reinforcement - Long Bars


Mu= 35395.47 k-in. Total moment on pile cap with offset
Mu= 3077.87 k-in./ft 1 ft strip design
d= 41.295 in.
As,required,structural,per ft= 1.434 in2/ft
As,required,structural,total= 16.490 in2
(4/3)As,required,structural,total= 21.987 in2
As,min,1=3(f'c)1/2bwd/fy= 15.607 in2
As,min,2=200bwd/fy= 18.996 in2
As,min,1 or 2, controlling= 18.996 in2
As,min,3=(0.0018 or 0.002)Ag= 12.668 in2
As,required= 18.996 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 62.852 in. OK; sufficient length available to develop bar
Req. number of long bars = 12.17
Prov. number of long bars = 15

122 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

123 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 41 in.
d/2= 20.5 in.
No. of piles outside d/2 from face of the column = 16
4(fc')0.5= 219.09 psi
b0= 256 in.
Vc= 2299.56 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1954.62 kips
Vu= 1940.32 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.993

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 41 in.
No. of piles outside d from face of the column = 3
0.5
2(fc') = 109.54 psi
bd= 4839.04 in2
Vc= 530.09 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 450.58 kips
Vu= 366.97 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.814

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 41 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 5229.96 in2
Vc= 572.91 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 486.98 kips
Vu= 245.18 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.503

(continued)

124 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 41 in.

d/2= 20.5 in.

No. of piles outside face of the column = 16


wactual= 9.500 in. < d/2 This procedure applies
Vu= 1915.06 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 256.000 in.
bs= 92.000 in.
k= 24.018 based on k=2(d/w)(1+d/c) acting at column face
Vc= 4962.20 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 4217.87 kips
Vu/f Vc= 0.454 ****COMBINED**** Vu/f Vc= 0.769

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 41.295 in.
w'= 22.676 in.
w'/d= 0.549 OK, this limit state should be checked
Vu= 838.90 kips
Mu= 30629.76 k-in.
Vud/Mu= 1.131
Mu/(Vud)= 0.884
k= 4.728
fVc= 1254.28 kips
Vu/f Vc= 0.669

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 39.955 in.
w'= 9.5 in.
w'/d= 0.238 OK, this limit state should be checked
Vu= 840.26 kips
Mu= 23270.87 k-in.
Vud/Mu= 1.443
Mu/(Vud)= 0.693
k= 10.000
fVc= 2877.74 kips
Vu/f Vc= 0.292

125 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

126 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 21.09 CY

Short Steel Bar Summary:


16 Total #10 Bars of length 11.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 758.6 lbs
Long Steel Bar Summary:
15 Total #11 Bars of length 12.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 987.6 lbs

Total weight of all steel = 1746.2 lbs or 0.873 tons

Comments:

127 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

128 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

18 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 100 tons
Pile Allowable Load (ASD) = 200 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 10 in. Note: Minimum cap dimensions
Pile Spacing, L= 3 ft. shown above. Actual dimensions
provided to the left referencing
Pile Edge Distance, E= 21 in. figure below.
Pile Cap Dmin,recommended= 32 in.
Pile Cap Dcap= 58 in.
Pile Cap Dimension A= 13.892 ft.
Pile Cap Dimension B= 12.5 ft.
Short Bars Size (No.) = 9
Long Bars Size (No.) = 10
Reinf. Effective dshort bars = 47.166 in.
Reinf. Effective dlong bars = 48.365 in.
Reinf. Effective dshear checks = 48 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5558.57 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 37.278 in.
Rounded Dimension c= 38 in.
(continued)

129 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 72639.33 k-in. Total moment on pile cap with offset
Mu= 5228.86 k-in./ft 1 ft strip design
d= 47.166 in.
As,required,structural,per ft= 2.155 in2/ft
As,required,structural,total= 29.942 in2
(4/3)As,required,structural,total= 39.923 in2
1/2
As,min,1=3(f'c) bwd/fy= 21.533 in2
As,min,2=200bwd/fy= 26.209 in2
As,min,1 or 2, controlling= 26.209 in2
As,min,3=(0.0018 or 0.002)Ag= 17.404 in2
As,required=
29.942 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.111
gs= 0.9472567 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 31.522 in2
As,required= 31.522 in2
cb= 4 in.
ld= 37.070 in.
lavailable= 53.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 31.54
Prov. number of short bars = 18

Required Flexural Reinforcement - Long Bars


Mu= 91884.32 k-in. Total moment on pile cap with offset
Mu= 7350.75 k-in./ft 1 ft strip design
d= 48.365 in.
As,required,structural,per ft= 3.004 in2/ft
As,required,structural,total= 37.548 in2
(4/3)As,required,structural,total= 50.064 in2
As,min,1=3(f'c)1/2bwd/fy= 19.868 in2
As,min,2=200bwd/fy= 24.183 in2
As,min,1 or 2, controlling= 24.183 in2
As,min,3=(0.0018 or 0.002)Ag= 15.660 in2
As,required= 37.548 in2
cb= 3.635 in.
ld= 41.736 in.
lavailable= 61.352 in. OK; sufficient length available to develop bar
Req. number of long bars = 29.64
Prov. number of long bars = 15

130 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

131 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48 in.
d/2= 24 in.
No. of piles outside d/2 from face of the column = 10
4(fc')0.5= 219.09 psi
b0= 344 in.
Vc= 3617.60 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3074.96 kips
Vu= 3058.14 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.995

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 7200.00 in2
Vc= 788.72 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 670.41 kips
Vu= -19.76 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.029

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 8001.79 in2
Vc= 876.55 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 745.07 kips
Vu= -10.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.014

(continued)

132 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 48 in.

d/2= 24 in.

No. of piles outside face of the column = 18


wactual= 2.000 in. < d/2 This procedure applies
Vu= 5570.20 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 344.000 in.
bs= 152.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 12787.79 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 10869.62 kips
Vu/f Vc= 0.512 ****COMBINED**** Vu/f Vc= 0.829

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.365 in.
w'= 15.176 in.
w'/d= 0.314 OK, this limit state should be checked
Vu= 2162.24 kips
Mu= 71397.56 k-in.
Vud/Mu= 1.465
Mu/(Vud)= 0.683
k= 10.000
fVc= 3377.55 kips
Vu/f Vc= 0.640

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.166 in.
w'= 2 in.
w'/d= 0.042 OK, this limit state should be checked
Vu= 2484.80 kips
Mu= 49094.34 k-in.
Vud/Mu= 2.387
Mu/(Vud)= 0.419
k= 10.000
fVc= 3660.62 kips
Vu/f Vc= 0.679

133 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

134 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 31.09 CY

Short Steel Bar Summary:


18 Total #9 Bars of length 12.000 ft (per bar)
0 Total Hooks of length 1.383 ft (per bar)
Weight = 734.5 lbs
Long Steel Bar Summary:
15 Total #10 Bars of length 13.392 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 865.9 lbs

Total weight of all steel = 1600.4 lbs or 0.800 tons

Comments:

135 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

136 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

19 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 8 in. Note: Minimum cap dimensions
shown above. Actual dimensions
Pile Spacing, L= 3 ft.
provided to the left referencing
Pile Edge Distance, E= 15 in. figure below.
Pile Cap Dmin,recommended= 23 in.
Pile Cap Dcap= 54 in.
Pile Cap Dimension A= 13.696 ft.
Pile Cap Dimension B= 11.5 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 42.955 in.
Reinf. Effective dlong bars = 44.295 in.
Reinf. Effective dshear checks = 44 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column
Net Column
CapacityCapacity
Pu= Pu= 2261.90 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Minimum Columumn Dimension c= 23.780 in.
Rounded Dimen ded Dimension c= 24 in.
(continued)

137 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 35569.83 k-in. Total moment on pile cap with offset
Mu= 2597.10 k-in./ft 1 ft strip design
d= 42.955 in.
As,required,structural,per ft= 1.155 in2/ft
As,required,structural,total= 15.818 in2
(4/3)As,required,structural,total= 21.091 in2
1/2
As,min,1=3(f'c) bwd/fy= 19.334 in2
As,min,2=200bwd/fy= 23.532 in2
As,min,1 or 2, controlling= 23.532 in2
As,min,3=(0.0018 or 0.002)Ag= 15.975 in2
As,required=
21.091 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.191
gs= 0.9128433 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 17.197 in2
As,required= 21.091 in2
cb= 4 in.
ld= 41.736 in.
lavailable= 54.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 16.65
Prov. number of short bars = 17

Required Flexural Reinforcement - Long Bars


Mu= 44281.28 k-in. Total moment on pile cap with offset
Mu= 3850.55 k-in./ft 1 ft strip design
d= 44.295 in.
As,required,structural,per ft= 1.677 in2/ft
As,required,structural,total= 19.290 in2
(4/3)As,required,structural,total= 25.720 in2
As,min,1=3(f'c)1/2bwd/fy= 16.740 in2
As,min,2=200bwd/fy= 20.376 in2
As,min,1 or 2, controlling= 20.376 in2
As,min,3=(0.0018 or 0.002)Ag= 13.414 in2
As,required= 20.376 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 67.176 in. OK; sufficient length available to develop bar
Req. number of long bars = 13.05
Prov. number of long bars = 13

138 of 206 09/13/2020 12:28:17


"CRSI-PILECAP" Program
Version 1.0

(continued)

139 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 44 in.
d/2= 22 in.
No. of piles outside d/2 from face of the column = 18
4(fc')0.5= 219.09 psi
b0= 272 in.
Vc= 2622.06 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2228.75 kips
Vu= 2168.58 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.973

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 44 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 6072.00 in2
Vc= 665.15 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 565.38 kips
Vu= 484.91 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.858

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 44 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 7231.49 in2
Vc= 792.17 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 673.34 kips
Vu= 495.98 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.737

(continued)

140 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 44 in.

d/2= 22 in.

No. of piles outside face of the column = 18


wactual= 9.000 in. < d/2 This procedure applies
Vu= 2138.22 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 272.000 in.
bs= 96.000 in.
k= 27.704 based on k=2(d/w)(1+d/c) acting at column face
Vc= 6409.47 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 5448.05 kips
Vu/f Vc= 0.392 ****COMBINED**** Vu/f Vc= 0.680

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 44.295 in.
w'= 22.176 in.
w'/d= 0.501 OK, this limit state should be checked
Vu= 951.37 kips
Mu= 38591.71 k-in.
Vud/Mu= 1.092
Mu/(Vud)= 0.916
k= 4.858
fVc= 1382.58 kips
Vu/f Vc= 0.688

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 42.955 in.
w'= 9 in.
w'/d= 0.210 OK, this limit state should be checked
Vu= 1081.74 kips
Mu= 29101.58 k-in.
Vud/Mu= 1.597
Mu/(Vud)= 0.626
k= 10.000
fVc= 3286.76 kips
Vu/f Vc= 0.329

141 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

142 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 26.25 CY

Short Steel Bar Summary:


17 Total #10 Bars of length 11.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 806.0 lbs
Long Steel Bar Summary:
13 Total #11 Bars of length 13.196 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 911.5 lbs

Total weight of all steel = 1717.5 lbs or 0.859 tons

Comments:

143 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

144 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

20 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 100 tons
Pile Allowable Load (ASD) = 200 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 10 in. Note: Minimum cap dimensions
shown above. Actual dimensions
Pile Spacing, L= 3 ft. provided to the left referencing
Pile Edge Distance, E= 21 in. figure below.11
Pile Cap Dmin,recommended= 55 in.
Pile Cap Dcap= 69 in.
Pile Cap Dimension A= 15.5 ft.
Pile Cap Dimension B= 12.5 ft.
Short Bars Size (No.) = 9
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 58.026 in.
Reinf. Effective dlong bars = 59.295 in.
Reinf. Effective dshear checks = 59 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 6132.63 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 39.156 in.
Rounded Dimension c= 40 in.
(continued)

145 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 89034.47 k-in. Total moment on pile cap with offset
Mu= 5744.16 k-in./ft 1 ft strip design
d= 58.026 in.
As,required,structural,per ft= 1.901 in2/ft
As,required,structural,total= 29.466 in2
(4/3)As,required,structural,total= 39.288 in2
1/2
As,min,1=3(f'c) bwd/fy= 29.557 in2
As,min,2=200bwd/fy= 35.976 in2
As,min,1 or 2, controlling= 35.976 in2
As,min,3=(0.0018 or 0.002)Ag= 23.101 in2
As,required=
35.976 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.240
gs= 0.8928571 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 32.623 in2
As,required= 35.976 in2
cb= 3 in.
ld= 40.910 in.
lavailable= 52.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 36.00
Prov. number of short bars = 36

Required Flexural Reinforcement - Long Bars


Mu= 115368.53 k-in. Total moment on pile cap with offset
Mu= 9229.48 k-in./ft 1 ft strip design
d= 59.295 in.
As,required,structural,per ft= 3.043 in2/ft
As,required,structural,total= 38.039 in2
(4/3)As,required,structural,total= 50.718 in2
As,min,1=3(f'c)1/2bwd/fy= 24.358 in2
As,min,2=200bwd/fy= 29.648 in2
As,min,1 or 2, controlling= 29.648 in2
As,min,3=(0.0018 or 0.002)Ag= 18.630 in2
As,required= 38.039 in2
cb= 3.100 in.
ld= 52.694 in.
lavailable= 70.000 in. OK; sufficient length available to develop bar
Req. number of long bars = 24.36
Prov. number of long bars = 24

146 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

147 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 59 in.
d/2= 29.5 in.
No. of piles outside d/2 from face of the column = 14
4(fc')0.5= 219.09 psi
b0= 396 in.
Vc= 5118.80 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 4350.98 kips
Vu= 4306.55 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.990

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 59 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 8850.00 in2
Vc= 969.47 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 824.05 kips
Vu= -20.13 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.024

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 59 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 10974.00 in2
Vc= 1202.14 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1021.82 kips
Vu= 7.13 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.007

(continued)

148 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 59 in.

d/2= 29.5 in.

No. of piles outside face of the column = 20


wactual= 1.000 in. < d/2 This procedure applies
Vu= 6147.96 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 396.000 in.
bs= 160.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 16545.60 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 14063.76 kips
Vu/f Vc= 0.437 ****COMBINED**** Vu/f Vc= 0.674

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 59.295 in.
w'= 19.000 in.
w'/d= 0.320 OK, this limit state should be checked
Vu= 2455.06 kips
Mu= 90889.78 k-in.
Vud/Mu= 1.602
Mu/(Vud)= 0.624
k= 10.000
fVc= 4140.84 kips
Vu/f Vc= 0.593

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 58.026 in.
w'= 1 in.
w'/d= 0.017 OK, this limit state should be checked
Vu= 3101.96 kips
Mu= 58103.97 k-in.
Vud/Mu= 3.098
Mu/(Vud)= 0.323
k= 10.000
fVc= 5024.76 kips
Vu/f Vc= 0.617

149 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

150 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 41.26 CY

Short Steel Bar Summary:


36 Total #9 Bars of length 12.000 ft (per bar)
0 Total Hooks of length 1.383 ft (per bar)
Weight = 1469.0 lbs
Long Steel Bar Summary:
24 Total #11 Bars of length 15.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1912.7 lbs

Total weight of all steel = 3381.7 lbs or 1.691 tons

Comments:

151 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

152 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

21 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 50 tons
Pile Allowable Load (ASD) = 100 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 8 in. shown above. Actual dimensions
Pile Spacing, L= 3 ft. provided to the left referencing
Pile Edge Distance, E= 15 figure below.
in.
Pile Cap Dmin,recommended= 24.5 in. A'= 3.334 ft.
Pile Cap Dcap= 60 in. B'= 10.918 ft.
Pile Cap Dimension A= 13.696 ft.
Pile Cap Dimension B= 13.696 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 48.885 in.
Reinf. Effective dlong bars = 50.295 in.
Reinf. Effective dshear checks = 50 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 3152.18 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 28.072 in.
Rounded Dimension c= 29 in.
(continued)

153 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 54057.29 k-in. Total moment on pile cap with offset
Mu= 3946.94 k-in./ft 1 ft strip design
d= 48.885 in.
As,required,structural,per ft= 1.549 in2/ft
As,required,structural,total= 21.215 in2
(4/3)As,required,structural,total= 28.286 in2
1/2
As,min,1=3(f'c) bwd/fy= 22.003 in2
As,min,2=200bwd/fy= 26.781 in2
As,min,1 or 2, controlling= 26.781 in2
As,min,3=(0.0018 or 0.002)Ag= 17.750 in2
As,required=
26.781 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.000
gs= 1 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 21.215 in2
As,required= 26.781 in2
cb= 4 in.
ld= 46.337 in.
lavailable= 64.676 in. OK; sufficient length available to develop bar
Req. number of short bars = 17.15
Prov. number of short bars = 17

Required Flexural Reinforcement - Long Bars


Mu= 56598.93 k-in. Total moment on pile cap with offset
Mu= 4132.52 k-in./ft 1 ft strip design
d= 50.295 in.
As,required,structural,per ft= 1.576 in2/ft
As,required,structural,total= 21.582 in2
(4/3)As,required,structural,total= 28.776 in2
As,min,1=3(f'c)1/2bwd/fy= 22.638 in2
As,min,2=200bwd/fy= 27.554 in2
As,min,1 or 2, controlling= 27.554 in2
As,min,3=(0.0018 or 0.002)Ag= 17.750 in2
As,required= 27.554 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 64.676 in. OK; sufficient length available to develop bar
Req. number of long bars = 17.65
Prov. number of long bars = 17

154 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

155 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 50 in.
d/2= 25 in.
No. of piles outside d/2 from face of the column = 12
4(fc')0.5= 219.09 psi
b0= 316 in.
Vc= 3461.61 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2942.37 kips
Vu= 1764.18 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.600

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 50 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 7024.67 in2
Vc= 769.51 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 654.09 kips
Vu= 624.43 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.955

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 50 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 8217.60 in2
Vc= 900.19 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 765.16 kips
Vu= 304.43 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.398

(continued)

156 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 50 in.
d/2= 25 in.
No. of piles outside face of the column = 20
wactual= 6.500 in. < d/2 This procedure applies
Vu= 2999.18 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 316.000 in.
bs= 116.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 10165.73 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 8640.87 kips
Vu/f Vc= 0.347

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 50.295 in.
w'= 6.500 in.
w'/d= 0.129 OK, this limit state should be checked
Vu= 1355.95 kips
Mu= 46866.92 k-in.
Vud/Mu= 1.455
Mu/(Vud)= 0.687
k= 10.000
fVc= 3848.39 kips
Vu/f Vc= 0.352 **CONTROLLING** Vu/f Vc= 0.352

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 48.885 in.
w'= 6.5 in.
w'/d= 0.133 OK, this limit state should be checked
Vu= 1355.95 kips
Mu= 44325.28 k-in.
Vud/Mu= 1.495
Mu/(Vud)= 0.669
k= 10.000
fVc= 3740.50 kips
Vu/f Vc= 0.363 **CONTROLLING** Vu/f Vc= 0.363
(continued)

157 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 32.07 CY

Short Steel Bar Summary:


17 Total #11 Bars of length 13.196 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1191.9 lbs
Long Steel Bar Summary:
17 Total #11 Bars of length 13.196 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1191.9 lbs

Total weight of all steel = 2383.8 lbs or 1.192 tons

Comments:

158 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

159 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

22 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 80 tons
Pile Allowable Load (ASD) = 160 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 10 in. shown above. Actual dimensions
Pile Spacing, L= 3 ft. provided to the left referencing
Pile Edge Distance, E= 21 figure below.
in.
Pile Cap Dmin,recommended= 29 in. A'= 11.021 ft.
Pile Cap Dcap= 62 in. B'= 6.134 ft.
Pile Cap Dimension A= 15.5 ft.
Pile Cap Dimension B= 13.892 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 50.885 in.
Reinf. Effective dlong bars = 52.295 in.
Reinf. Effective dshear checks = 52 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5386.54 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 36.697 in.
Rounded Dimension c= 37 in.
(continued)

161 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 85687.02 k-in. Total moment on pile cap with offset
Mu= 5528.20 k-in./ft 1 ft strip design
d= 50.885 in.
As,required,structural,per ft= 2.103 in2/ft
As,required,structural,total= 32.601 in2
(4/3)As,required,structural,total= 43.468 in2
1/2
As,min,1=3(f'c) bwd/fy= 25.920 in2
As,min,2=200bwd/fy= 31.549 in2
As,min,1 or 2, controlling= 31.549 in2
As,min,3=(0.0018 or 0.002)Ag= 20.758 in2
As,required=
32.601 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.116
gs= 0.9452912 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 34.384 in2
As,required= 34.384 in2
cb= 4 in.
ld= 46.337 in.
lavailable= 61.852 in. OK; sufficient length available to develop bar
Req. number of short bars = 22.02
Prov. number of short bars = 18

Required Flexural Reinforcement - Long Bars


Mu= 90462.96 k-in. Total moment on pile cap with offset
Mu= 6511.87 k-in./ft 1 ft strip design
d= 52.295 in.
As,required,structural,per ft= 2.422 in2/ft
As,required,structural,total= 33.653 in2
(4/3)As,required,structural,total= 44.870 in2
As,min,1=3(f'c)1/2bwd/fy= 23.875 in2
As,min,2=200bwd/fy= 29.059 in2
As,min,1 or 2, controlling= 29.059 in2
As,min,3=(0.0018 or 0.002)Ag= 18.604 in2
As,required= 33.653 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 71.500 in. OK; sufficient length available to develop bar
Req. number of long bars = 21.55
Prov. number of long bars = 17

162 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

163 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 52 in.
d/2= 26 in.
No. of piles outside d/2 from face of the column = 14
4(fc')0.5= 219.09 psi
b0= 356 in.
Vc= 4055.78 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3447.41 kips
Vu= 3406.75 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.988

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 52 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 7880.50 in2
Vc= 863.27 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 733.78 kips
Vu= 490.47 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.668

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 52 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 7648.68 in2
Vc= 837.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 712.19 kips
Vu= -9.81 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.014

(continued)

164 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 52 in.

d/2= 26 in.

No. of piles outside face of the column = 22


wactual 2.500 in. < d/2 This procedure applies
Vu 5398.33 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 356.000 in.
bs= 148.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 13488.87 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 11465.54 kips
Vu/f Vc= 0.471 ****COMBINED**** Vu/f Vc= 0.707

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 52.295 in.
w'= 2.500 in.
w'/d= 0.048 OK, this limit state should be checked
Vu= 2463.83 kips
Mu= 67833.62 k-in.
Vud/Mu= 1.899
Mu/(Vud)= 0.526
k= 10.000
fVc= 4058.69 kips
Vu/f Vc= 0.607 **CONTROLLING** Vu/f Vc= 0.607

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 50.885 in.
w'= 15.676 in.
w'/d= 0.308 OK, this limit state should be checked
Vu= 2210.90 kips
Mu= 65404.36 k-in.
Vud/Mu= 1.720
Mu/(Vud)= 0.581
k= 10.000
fVc= 4406.38 kips
Vu/f Vc= 0.502 **CONTROLLING** Vu/f Vc= 0.50175

165 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

166 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 37.88 CY

Short Steel Bar Summary:


18 Total #11 Bars of length 13.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1280.8 lbs
Long Steel Bar Summary:
17 Total #11 Bars of length 15.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1354.8 lbs

Total weight of all steel = 2635.6 lbs or 1.318 tons

Comments:

167 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

168 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

23 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 40 tons
Pile Allowable Load (ASD) = 80 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 8 in. shown above. Actual dimensions
Pile Spacing, L= 3 ft. provided to the left referencing
Pile Edge Distance, E= 15 figure below.
in.
Pile Cap Dmin,recommended= 23 in. A'= 10.443 ft.
Pile Cap Dcap= 58 in. B'= 6.670 ft.
Pile Cap Dimension A= 14.5 ft.
Pile Cap Dimension B= 13.696 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 46.885 in.
Reinf. Effective dlong bars = 48.295 in.
Reinf. Effective dshear checks = 48 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2730.16 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 26.125 in.
Rounded Dimension c= 27 in.
(continued)

169 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 49690.09 k-in. Total moment on pile cap with offset
Mu= 3426.90 k-in./ft 1 ft strip design
d= 46.885 in.
As,required,structural,per ft= 1.400 in2/ft
As,required,structural,total= 20.299 in2
(4/3)As,required,structural,total= 27.065 in2
1/2
As,min,1=3(f'c) bwd/fy= 22.342 in2
As,min,2=200bwd/fy= 27.193 in2
As,min,1 or 2, controlling= 27.193 in2
As,min,3=(0.0018 or 0.002)Ag= 18.166 in2
As,required=
27.065 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.059
gs= 0.9714853 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 20.878 in2
As,required= 27.065 in2
cb= 4 in.
ld= 46.337 in.
lavailable= 65.676 in. OK; sufficient length available to develop bar
Req. number of short bars = 17.33
Prov. number of short bars = 17

Required Flexural Reinforcement - Long Bars


Mu= 51492.89 k-in. Total moment on pile cap with offset
Mu= 3759.70 k-in./ft 1 ft strip design
d= 48.295 in.
As,required,structural,per ft= 1.492 in2/ft
As,required,structural,total= 20.440 in2
(4/3)As,required,structural,total= 27.254 in2
As,min,1=3(f'c)1/2bwd/fy= 21.737 in2
As,min,2=200bwd/fy= 26.458 in2
As,min,1 or 2, controlling= 26.458 in2
As,min,3=(0.0018 or 0.002)Ag= 17.158 in2
As,required= 26.458 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 70.500 in. OK; sufficient length available to develop bar
Req. number of long bars = 16.94
Prov. number of long bars = 17

170 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

171 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48 in.
d/2= 24 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 219.09 psi
b0= 300 in.
Vc= 3154.88 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2681.65 kips
Vu= 2647.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.987

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 109.54 psi
bd= 7888.90 in2
Vc= 864.19 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 734.56 kips
Vu= 358.50 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.488

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 7161.42 in2
Vc= 784.49 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 666.82 kips
Vu= 491.28 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.737

(continued)

172 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 48 in.
d/2= 24 in.
No. of piles outside face of the column = 22
wactual= 25.500 in. > d/2 Limit state not applicable
Vu= 2608.04 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 300.000 in.
bs= 108.000 in.
k= 10.458 based on k=2(d/w)(1+d/c) acting at column face
Vc= 2969.30 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 2523.91 kips
Vu/f Vc= 1.033

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.295 in.
w'= 7.500 in.
w'/d= 0.155 OK, this limit state should be checked
Vu= 1190.96 kips
Mu= 43539.89 k-in.
Vud/Mu= 1.321
Mu/(Vud)= 0.757
k= 10.000
fVc= 3695.36 kips
Vu/f Vc= 0.322 **CONTROLLING** Vu/f Vc= 0.322

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 46.885 in.
w'= 25.5 in.
w'/d= 0.544 OK, this limit state should be checked
Vu= 1064.00 kips
Mu= 42595.78 k-in.
Vud/Mu= 1.171
Mu/(Vud)= 0.854
k= 5.064
fVc= 1923.21 kips
Vu/f Vc= 0.553 **CONTROLLING** Vu/f Vc= 0.553
(continued)

173 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 33.00 CY

Short Steel Bar Summary:


17 Total #11 Bars of length 13.196 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1191.9 lbs
Long Steel Bar Summary:
17 Total #11 Bars of length 14.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1264.5 lbs

Total weight of all steel = 2456.4 lbs or 1.228 tons

Comments:

174 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

175 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

24 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 80 tons
Pile Allowable Load (ASD) = 160 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 10 in. Note: Minimum cap dimensions
Pile Spacing, L= 3 shown above. Actual dimensions
ft.
provided to the left referencing
Pile Edge Distance, E= 21 in. figure below.
Pile Cap Dmin,recommended= 55 in.
Pile Cap Dcap= 66 in.
Pile Cap Dimension A= 15.5 ft.
Pile Cap Dimension B= 14.696 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 54.955 in.
Reinf. Effective dlong bars = 56.295 in.
Reinf. Effective dshear checks = 56 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5843.32 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 38.221 in.
Rounded Dimension c= 39 in.
(continued)

177 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 103367.14 k-in. Total moment on pile cap with offset
Mu= 6668.85 k-in./ft 1 ft strip design
d= 54.955 in.
As,required,structural,per ft= 2.353 in2/ft
As,required,structural,total= 36.467 in2
(4/3)As,required,structural,total= 48.622 in2
1/2
As,min,1=3(f'c) bwd/fy= 27.993 in2
As,min,2=200bwd/fy= 34.072 in2
As,min,1 or 2, controlling= 34.072 in2
As,min,3=(0.0018 or 0.002)Ag= 22.097 in2
As,required=
36.467 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.055
gs= 0.973374 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 37.438 in2
As,required= 37.438 in2
cb= 4 in.
ld= 41.736 in.
lavailable= 65.676 in. OK; sufficient length available to develop bar
Req. number of short bars = 29.55
Prov. number of short bars = 16

Required Flexural Reinforcement - Long Bars


Mu= 106142.16 k-in. Total moment on pile cap with offset
Mu= 7222.52 k-in./ft 1 ft strip design
d= 56.295 in.
As,required,structural,per ft= 2.491 in2/ft
As,required,structural,total= 36.606 in2
(4/3)As,required,structural,total= 48.807 in2
As,min,1=3(f'c)1/2bwd/fy= 27.188 in2
As,min,2=200bwd/fy= 33.092 in2
As,min,1 or 2, controlling= 33.092 in2
As,min,3=(0.0018 or 0.002)Ag= 20.951 in2
As,required= 36.606 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 70.500 in. OK; sufficient length available to develop bar
Req. number of long bars = 23.44
Prov. number of long bars = 16

178 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

179 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 56 in.
d/2= 28 in.
No. of piles outside d/2 from face of the column = 16
4(fc')0.5= 219.09 psi
b0= 380 in.
Vc= 4662.21 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3962.88 kips
Vu= 3878.05 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.979

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 56 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 9875.71 in2
Vc= 1081.83 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 919.56 kips
Vu= -28.29 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.031

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 56 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 10416.00 in2
Vc= 1141.02 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 969.86 kips
Vu= -21.61 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.022

(continued)

180 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 56 in.

d/2= 28 in.

No. of piles outside face of the column = 24


wactual= 1.500 in. < d/2 This procedure applies
Vu= 5857.26 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 380.000 in.
bs= 156.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 15311.69 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 13014.94 kips
Vu/f Vc= 0.450 ****COMBINED**** Vu/f Vc= 0.612

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 56.295 in.
w'= 1.500 in.
w'/d= 0.027 OK, this limit state should be checked
Vu= 2441.18 kips
Mu= 82417.47 k-in.
Vud/Mu= 1.667
Mu/(Vud)= 0.600
k= 10.000
fVc= 4622.00 kips
Vu/f Vc= 0.528

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 54.955 in.
w'= 14.676 in.
w'/d= 0.267 OK, this limit state should be checked
Vu= 2442.91 kips
Mu= 79629.83 k-in.
Vud/Mu= 1.686
Mu/(Vud)= 0.593
k= 10.000
fVc= 4758.82 kips
Vu/f Vc= 0.513

181 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

182 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 46.40 CY

Short Steel Bar Summary:


16 Total #10 Bars of length 14.196 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 979.0 lbs
Long Steel Bar Summary:
16 Total #11 Bars of length 15.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1275.1 lbs

Total weight of all steel = 2254.2 lbs or 1.127 tons

Comments:

183 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

184 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

26 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 60 tons
Pile Allowable Load (ASD) = 120 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Note: Minimum cap dimensions
Minimum Pile Dimension dp= 8 in. shown above. Actual dimensions
Pile Spacing, L= 3 provided to the left referencing
ft.
figure below.
Pile Edge Distance, E= 15 in.
Pile Cap Dmin,recommended= 26 in. A'= 8.867 ft.
Pile Cap Dcap= 68 in. B'= 10.444 ft.
Pile Cap Dimension A= 15.892 ft.
Pile Cap Dimension B= 14.5 ft.
Short Bars Size (No.) = 11
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 56.885 in.
Reinf. Effective dlong bars = 58.295 in.
Reinf. Effective dshear checks = 58 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 4697.99 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 34.271 in.
Rounded Dimension c= 35 in.
(continued)

185 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 78770.14 k-in. Total moment on pile cap with offset
Mu= 4956.59 k-in./ft 1 ft strip design
d= 56.885 in.
As,required,structural,per ft= 1.668 in2/ft
As,required,structural,total= 26.509 in2
(4/3)As,required,structural,total= 35.345 in2
1/2
As,min,1=3(f'c) bwd/fy= 29.709 in2
As,min,2=200bwd/fy= 36.161 in2
As,min,1 or 2, controlling= 36.161 in2
As,min,3=(0.0018 or 0.002)Ag= 23.342 in2
As,required=
35.345 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.096
gs= 0.9541985 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 27.723 in2
As,required= 35.345 in2
cb= 4 in.
ld= 46.337 in.
lavailable= 66.500 in. OK; sufficient length available to develop bar
Req. number of short bars = 22.64
Prov. number of short bars = 22

Required Flexural Reinforcement - Long Bars


Mu= 103016.51 k-in. Total moment on pile cap with offset
Mu= 7104.59 k-in./ft 1 ft strip design
d= 58.295 in.
As,required,structural,per ft= 2.357 in2/ft
As,required,structural,total= 34.182 in2
(4/3)As,required,structural,total= 45.577 in2
As,min,1=3(f'c)1/2bwd/fy= 27.779 in2
As,min,2=200bwd/fy= 33.811 in2
As,min,1 or 2, controlling= 33.811 in2
As,min,3=(0.0018 or 0.002)Ag= 21.298 in2
As,required= 34.182 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 74.852 in. OK; sufficient length available to develop bar
Req. number of long bars = 21.89
Prov. number of long bars = 22

186 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

187 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 58 in.
d/2= 29 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 219.09 psi
b0= 372 in.
Vc= 4727.06 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 4018.01 kips
Vu= 4011.67 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.998

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 58 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 8598.60 in2
Vc= 941.93 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 800.64 kips
Vu= 745.06 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.931

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 58 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 10201.15 in2
Vc= 1117.48 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 949.86 kips
Vu= -11.02 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.012

(continued)

188 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 58 in.
d/2= 29 in.
No. of piles outside face of the column = 26
wactual= 3.500 in. < d/2 This procedure applies
Vu= 4709.55 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 372.000 in.
bs= 140.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 14232.02 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 12097.22 kips
Vu/f Vc= 0.389

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 58.295 in.
w'= 3.500 in.
w'/d= 0.060 OK, this limit state should be checked
Vu= 2377.75 kips
Mu= 82358.86 k-in.
Vud/Mu= 1.683
Mu/(Vud)= 0.594
k= 10.000
fVc= 4722.37 kips
Vu/f Vc= 0.504 **CONTROLLING** Vu/f Vc= 0.504

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 56.885 in.
w'= 3.5 in.
w'/d= 0.062 OK, this limit state should be checked
Vu= 2188.51 kips
Mu= 59774.38 k-in.
Vud/Mu= 2.083
Mu/(Vud)= 0.480
k= 10.000
fVc= 5050.53 kips
Vu/f Vc= 0.433 **CONTROLLING** Vu/f Vc= 0.433
(continued)

189 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 45.37 CY

Short Steel Bar Summary:


22 Total #11 Bars of length 14.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1636.4 lbs
Long Steel Bar Summary:
22 Total #11 Bars of length 15.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1799.1 lbs

Total weight of all steel = 3435.6 lbs or 1.718 tons

Comments:

190 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

191 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

28 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject:
Job Number: Originator: Checker:
Input:
Pile Type = Steel
Pile Shape = Round
Concrete Comp. Strength, f'c= 3 ksi
Steel Reinforcing Yield, fy= 60 ksi
Accidential Pile Offset = 3 in.
Pile Allowable Load (ASD) = 60 tons
Pile Allowable Load (ASD) = 120 kips
Minimum Pile Embedment = 6 in.
Clear Cover Over Top of Pile= 3 in.
Minimum Pile Dimension dp= 8 in. Note: Minimum cap dimensions
Pile Spacing, L= 3 ft.
shown above. Actual dimensions
provided to the left referencing
Pile Edge Distance, E= 15 in. figure below.
Pile Cap Dmin,recommended= 55 in.
Pile Cap Dcap= 68 in.
Pile Cap Dimension A= 15.892 ft.
Pile Cap Dimension B= 14.5 ft.
Short Bars Size (No.) = 10
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 56.955 in.
Reinf. Effective dlong bars = 58.295 in.
Reinf. Effective dshear checks = 58 in.

Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5062.61 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 35.576 in.
Rounded Dimension c= 36 in.
(continued)

193 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 91289.07 k-in. Total moment on pile cap with offset
Mu= 5744.34 k-in./ft 1 ft strip design
d= 56.955 in.
As,required,structural,per ft= 1.939 in2/ft
As,required,structural,total= 30.817 in2
(4/3)As,required,structural,total= 41.089 in2
1/2
As,min,1=3(f'c) bwd/fy= 29.746 in2
As,min,2=200bwd/fy= 36.205 in2
As,min,1 or 2, controlling= 36.205 in2
As,min,3=(0.0018 or 0.002)Ag= 23.342 in2
As,required=
36.205 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.096
gs= 0.9541985 % steel concentrated of width B of long side A
As,required,structural,total,modfied= 32.228 in2
As,required= 36.205 in2
cb= 3 in.
ld= 41.736 in.
lavailable= 66.000 in. OK; sufficient length available to develop bar
Req. number of short bars = 28.58
Prov. number of short bars = 28

Required Flexural Reinforcement - Long Bars


Mu= 109930.19 k-in. Total moment on pile cap with offset
Mu= 7581.39 k-in./ft 1 ft strip design
d= 58.295 in.
As,required,structural,per ft= 2.523 in2/ft
As,required,structural,total= 36.577 in2
(4/3)As,required,structural,total= 48.769 in2
As,min,1=3(f'c)1/2bwd/fy= 27.779 in2
As,min,2=200bwd/fy= 33.811 in2
As,min,1 or 2, controlling= 33.811 in2
As,min,3=(0.0018 or 0.002)Ag= 21.298 in2
As,required= 36.577 in2
cb= 3.705 in.
ld= 46.337 in.
lavailable= 74.352 in. OK; sufficient length available to develop bar
Req. number of long bars = 23.43
Prov. number of long bars = 23

194 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

(continued)

195 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 58 in.
d/2= 29 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 219.09 psi
b0= 376 in.
Vc= 4777.89 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 4061.21 kips
Vu= 3994.06 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.983

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 58 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 109.54 psi
bd= 10092.00 in2
Vc= 1105.52 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 939.69 kips
Vu= 928.20 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.988

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 58 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 11060.83 in2
Vc= 1211.65 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1029.91 kips
Vu= -19.81 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.019

(continued)

196 of 206 09/13/2020 12:28:18


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 -


d= 58 in.

d/2= 29 in.

No. of piles outside face of the column = 28


wactual= 3.000 in. < d/2 This procedure applies
Vu 5074.85 kips
0.5
4(fc') = 219.09 psi
0.5
32(fc') = 1752.71 psi
b0= 376.000 in.
bs= 144.000 in.
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face
Vc= 14638.65 kips based on Vc=k(fc')0.5bsd acting at column face
fVc= 12442.85 kips
Vu/f Vc= 0.408

Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 58.295 in.
w'= 3.000 in.
w'/d= 0.051 OK, this limit state should be checked
Vu= 2560.88 kips
Mu= 86948.78 k-in.
Vud/Mu= 1.717
Mu/(Vud)= 0.582
k= 10.000
fVc= 4722.37 kips
Vu/f Vc= 0.542

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 56.955 in.
w'= 3 in.
w'/d= 0.053 OK, this limit state should be checked
Vu= 2179.72 kips
Mu= 71744.50 k-in.
Vud/Mu= 1.730
Mu/(Vud)= 0.578
k= 10.000
fVc= 5056.75 kips
Vu/f Vc= 0.431

197 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

(continued)

198 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary:
Quantity = 48.36 CY

Short Steel Bar Summary:


28 Total #10 Bars of length 14.000 ft (per bar)
0 Total Hooks of length 1.557 ft (per bar)
Weight = 1689.7 lbs
Long Steel Bar Summary:
23 Total #11 Bars of length 15.392 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 1880.9 lbs

Total weight of all steel = 3570.6 lbs or 1.785 tons

Comments:

199 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

200 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

30 PILE CAP (Traditional CRSI Approach)


for Vertical Loading
Per ACI 318-11 Building Code
Job Name: Subject: ###
Job Number: Originator: Checker: ###
Input: ###
Pile Type = Steel ###
Pile Shape = Round Bar No.
Concrete Comp. Strength, f'c= 3 ksi ###
Steel Reinforcing Yield, fy= 60 ksi ###
Accidential Pile Offset = 3 in. ###
Pile Allowable Load (ASD) = 40 tons ###
Pile Allowable Load (ASD) = 80 kips ###
Minimum Pile Embedment = 6 in. ###
Clear Cover Over Top of Pile= 3 in. ###
Minimum Pile Dimension dp= 8 in. Note: Minimum cap dimensions ###
Pile Spacing, L= 3 ft. shown above. Actual dimensions ###
provided to the left referencing
Pile Edge Distance, E= 15 in. ###
figure below.
Pile Cap Dmin,recommended= 55 in. Short hook ad
Pile Cap Dcap= 59 in. Long hook ad
Pile Cap Dimension A= 17.5 ft. Short Bar Dia
Pile Cap Dimension B= 14.5 ft. Short Bar Are
Short Bars Size (No.) = 11 Steel pile em
Long Bars Size (No.) = 11
Reinf. Effective dshort bars = 47.885 in.
Reinf. Effective dlong bars = 49.295 in.
Reinf. Effective dshear checks = 49 in. If given pile is

Design Checks: Equivalent Pi


Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK d=
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK d/2=
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK Diameter for
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK Area in shear
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK 4(fc')0.5=
CRSI Limit State 6 Adequate? OK Vc=
Results:
Column Size Determination Vu=
Net Column Capacity Pu= 3540.58 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 29.751 in.
Rounded Dimension c= 30 in.
(continued)

201 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

Required Flexural Reinforcement - Short Bars


Mu= 70593.95 k-in. Total moment on pile cap with offset
Mu= 4033.94 k-in./ft 1 ft strip design
d= 47.885 in.
As,required,structural,per ft= 1.619 in2/ft
As,required,structural,total= 28.338 in2
(4/3)As,required,structural,total= 37.785 in2
As,min,1=3(f'c)1/2bwd/fy= 27.539 in2
As,min,2=200bwd/fy= 33.520 in2
As,min,1 or 2, controlling= 33.520
As,min,3=(0.0018 or 0.002)Ag= 22.302 in2
As,required=
33.520 in2
Increase the calculated area of steel to maintain uniform spacing (ACI 15.4.4)
b=A/B= 1.207
g s= 0.90625 % steel concentrated of width B of long side A c. to c. spacing of l
As,required,structural,total,modfied= 30.995 in2 concrete cover =
As,required= 33.520 in2 cb=

cb = 3 in.
ld= 51.600 in. y t=

lavailable= 69.000 in. OK; sufficient length available to develop bar ye=
Req. number of short bars = 21.47 ys=
Prov. number of short bars = 33 (cb+Ktr)/db=
ld=

Required Flexural Reinforcement - Long Bars lavailable=

Mu= 88262.84 k-in. Total moment on pile cap with offset


Mu= 6087.09 k-in./ft 1 ft strip design
d= 49.295 in.
As,required,structural,per ft= 2.408 in2/ft c. to c. spacing of l
As,required,structural,total= 34.920 in2
concrete cover =
(4/3)As,required,structural,total= 46.559 in2 cb=
1/2
As,min,1=3(f'c) bwd/fy= 23.490 in2
As,min,2=200bwd/fy= 28.591 in2 yt=

As,min,1 or 2, controlling= 28.591 ye=

As,min,3=(0.0018 or 0.002)Ag= 18.479 in2 ys=

As,required= 34.920 in2 (cb+Ktr)/db=

cb = 3.332 in. ld=

ld= 49.024 lavailable=

lavailable= 87.000 in. OK; sufficient length available to develop bar


Req. number of long bars = 22.36
Prov. number of long bars = 26

202 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

(continued)

203 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 49 in. distance from
d/2= 24.5 in. distance from
No. of piles outside d/2 from face of the column = 24 distance from
4(fc')0.5= 219.09 psi distance from
b 0= 316 in. distance from
0.5
Vc= 3392.37 kips based on Vc=4(fc') b0d acting at d/2 from column face distance from
f Vc= 2883.52 kips
Vu= 2823.72 kips reduced by weight of concrete outside of critical section Limit State Al
Vu/f Vc= 0.979

Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 49 in. distance from
No. of piles outside d from face of the column = 5 distance from
2(fc')0.5= 109.54 psi distance from
bd= 8526.00 in2 distance from
Vc= 933.98 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 793.88 kips
Vu= 581.54 kips reduced by weight of concrete outside of critical section Limit State Al
Vu/f Vc= 0.733

Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 49 in. distance from
No. of piles outside d from face of the column = 6 distance from
2(fc')0.5= 109.54 psi distance from
bd= 10290.00 in2

Vc= 1127.21 kips based on Vc=2(fc')0.5bd acting at d from column face


fVc= 958.13 kips
Vu= 728.42 kips reduced by weight of concrete outside of critical section Limit State Al
Vu/f Vc= 0.760

(continued)

204 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

Check two way shear at column face - CRSI LIMIT STATE 4 - waverage
d= 49 in. Make sure lar
d/2= 24.5 in. NG, but answ
No. of piles outside face of the column = 30 32(fc')0.5=
wactual= 6.000 in. < d/2 This procedure applies ###
Vu= 3547.95 kips ###
0.5
4(fc') = 219.09 psi 4(fc')0.5=
32(fc')0.5= 1752.71 psi 32(fc')0.5=
b 0= 316.000 in. b0=
b s= 120.000 in. Limit State Al
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face k=
Vc= 10305.95 kips based on Vc=k(fc')0.5bsd acting at column face ###
fVc= 8760.06 kips ###
Vu/f Vc= 0.405 ****COMBINED**** Vu/f Vc= 0.80516 ###

Check deep beam (one way shear through short width) at face of column ###
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 49.295 in. Limit State Al
w'= 6.000 in. w'=
w'/d= 0.122 OK, this limit state should be checked w'/d=
Vu= 1791.68 kips Vu=
Mu= 74865.38 k-in. M u=
Vud/Mu= 1.180 Vud/Mu=
Mu/(Vud)= 0.848 Mu/(Vud)=
k= 10.000 k=
fVc= 3993.30 kips
Vu/f Vc= 0.449 **CONTROLLING** Vu/f Vc= 0.449

Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.885 in. Limit State Al
w'= 24 in. w'=
w'/d= 0.501 OK, this limit state should be checked w'/d=
Vu= 1412.10 kips Vu=
Mu= 60051.60 k-in. M u=
Vud/Mu= 1.126 Vud/Mu=
Mu/(Vud)= 0.888 Mu/(Vud)=
k= 5.139 k=
fVc= 2405.88 kips
Vu/f Vc= 0.587 **CONTROLLING** Vu/f Vc= 0.587
(continued)

205 of 206 09/13/2020 12:28:19


"CRSI-PILECAP" Program
Version 1.0

Quantities of Concrete and Reinforcing Bars


Concrete Summary: d=
Quantity = 46.21 CY d/2=
Diameter for
Short Steel Bar Summary: Area in shear
33 Total #11 Bars of length 14.000 ft (per bar) 4(fc')0.5=
0 Total Hooks of length 1.728 ft (per bar) Vc=
Weight = 2454.7 lbs
Long Steel Bar Summary: Vu=
26 Total #11 Bars of length 17.000 ft (per bar)
0 Total Hooks of length 1.728 ft (per bar)
Weight = 2348.4 lbs
d=
Total weight of all steel = 4803.1 lbs or 2.402 tons d/2=
Straight dime
Round dimen
Comments: Area in shear
4(fc')0.5=
Vc=

Vu=

d=
d/2=
Length dimen
Area in shear
4(fc')0.5=
Vc=

Vu=
Vu/f Vc=

d=
dcritical=
diagonal =
Area in shear
2(fc')0.5=
Vc=

206 of 206 09/13/2020 12:28:19