Professional Documents
Culture Documents
Program Description:
"CRSI-PILECAP" is a spreadsheet program written in MS-Excel for the design and analysis of rigid pile
caps. Pile caps are designed and analyzed in accordance with ACI 318-11 with modifications as necessary
to account for beam shear and punching shear when piles are placed inside the ACI assumed shear failure plane.
Users input the pile type/material, pile shape, pile allowable load, pile size, pile cap material properties,
pile cap depth, bar size, and minimum pile eccentrity (which can also be used to increase pile cap moment demand
if so desired). Design requires the user to simply yet interatively choose a minimum design depth that satisfies
all limit states required by ACI and those recommended by CRSI. The load combination used to change from pile
allowable load to factored load is 1.6(D+Lfloor) and the assumed strength resistance factor for shear is f = 0.85.
The chosen load factor and strength reduction factor were chosen to provide a factor of safety against shear failure
equivalent to that which was used in the CRSI Design Handbook (2008).
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 32 in. distance fro
d/2= 16 in. distance fro
No. of piles outside d/2 from face of the column = 0 distance fro
4(fc')0.5= 252.98 psi
b0= 84 in.
Vc= 680.02 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face Limit State A
f Vc= 578.01 kips
Vu= -6.77 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.012
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 32 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 126.49 psi
bd= 1344.00 in2 Limit State A
0.5
Vc= 170.00 kips based on Vc=2(fc') bd acting at d from column face
fVc= 144.50 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 32.436 in.
w'= 14 in.
w'/d= 0.432 OK, this limit state should be checked
Vu= 376.16 kips
Mu= 5250.56 k-in. Limit State A
Vud/Mu= 2.324
Mu/(Vud)= 0.430
k= 10.000
fVc= 732.36 kips
Vu/f Vc= 0.514
Conservatively assuming w'/d=1.0,
Vud/Mu= 2.324
Mu/(Vud)= 0.430
k= 5.169
fVc= 378.57 kips
Vu/f Vc= 0.994
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? Not Applicable CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? Not Applicable CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1126.62 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 18.937 in.
Rounded Dimension c= 19 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 31 in.
d/2= 15.5 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 252.98 psi
b0= 157.075 in.
Vc= 1231.85 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1047.07 kips
Vu= -22.58 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.022
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 31 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 797.65 in2
Vc= 100.90 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 85.76 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.0000
(continued)
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 30.095 in.
w'= 14.272 in.
w'/d= 0.474 OK, this limit state should be checked
Vu= 384.00 kips
Mu= 5480.45 k-in.
Vud/Mu= 2.109
Mu/(Vud)= 0.474
k= 10.000
fVc= 995.41 kips
Vu/f Vc= 0.386 Above 0.609 Below 0.609 Controlling
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1503.05 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 19.385 in.
Rounded Dimension c= 20 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 29 in.
d/2= 14.5 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 252.98 psi
b0= 196 in.
Vc= 1437.95 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1222.26 kips
Vu= -19.95 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.016
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 29 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 2262.00 in2
Vc= 286.12 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 243.20 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 29 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 2262.00 in2
Vc= 286.12 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 243.20 kips
Vu= 0.00 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.000
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 29.436 in.
w'= 11.000 in.
w'/d= 0.374 OK, this limit state should be checked
Vu= 755.75 kips
Mu= 8270.34 k-in.
Vud/Mu= 2.690
Mu/(Vud)= 0.372
k= 10.000
fVc= 1234.30 kips
Vu/f Vc= 0.612
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 28.308 in.
w'= 11 in.
w'/d= 0.389 OK, this limit state should be checked
Vu= 755.75 kips
Mu= 8270.34 k-in.
Vud/Mu= 2.587
Mu/(Vud)= 0.387
k= 10.000
fVc= 1187.01 kips
Vu/f Vc= 0.637
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop hooks? NG; select smaller bar size
CRSI Limit State 1 Adequate? NG
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? Not applicable CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NG
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1868.44 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.613 in.
Rounded Dimension c= 22 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 33 in.
d/2= 16.5 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 219.09 psi
b0= 220 in.
Vc= 1590.59 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1352.00 kips
Vu= 1502.51 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 1.111
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 33 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 3066.07 in2
Vc= 335.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 285.49 kips
Vu= -1.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.005
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 33 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 3066.07 in2
Vc= 335.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 285.49 kips
Vu= -1.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.005
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 33.365 in.
w'= 17.456 in.
w'/d= 0.523 OK, this limit state should be checked
Vu= 748.33 kips
Mu= 13057.13 k-in.
Vud/Mu= 1.912
Mu/(Vud)= 0.523
k= 8.764
fVc= 1264.90 kips
Vu/f Vc= 0.592
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 32.095 in.
w'= 17.4556 in.
w'/d= 0.544 OK, this limit state should be checked
Vu= 748.33 kips
Mu= 13057.13 k-in.
Vud/Mu= 1.839
Mu/(Vud)= 0.544
k= 8.203
fVc= 1138.84 kips
Vu/f Vc= 0.657
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NG CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2244.72 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 23.689 in.
Rounded Dimension c= 24 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38 in.
d/2= 19 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 252.98 psi
b0= 248 in.
Vc= 2384.10 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2026.49 kips
Vu= 1502.35 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.741
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 2964.00 in2
Vc= 374.92 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 318.68 kips
Vu= -3.64 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.011
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 126.49 psi
bd= 4332.00 in2
Vc= 547.96 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 465.77 kips
Vu= 8.36 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.018
(continued)
d/2= 19 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.365 in.
w'= 27.000 in.
w'/d= 0.704 OK, this limit state should be checked
Vu= 744.60 kips
Mu= 20209.50 k-in.
Vud/Mu= 1.414
Mu/(Vud)= 0.707
k= 5.022
fVc= 807.90 kips
Vu/f Vc= 0.922
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 37.095 in.
w'= 9 in.
w'/d= 0.243 OK, this limit state should be checked
Vu= 1131.48 kips
Mu= 10090.98 k-in.
Vud/Mu= 4.159
Mu/(Vud)= 0.240
k= 10.000
fVc= 2273.36 kips
Vu/f Vc= 0.498
(continued)
Comments:
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 74 in.
d/2= 37 in.
No. of piles outside d/2 from face of the column = 0
4(fc')0.5= 219.09 psi
b0= 398.98193 in.
Vc= 6468.53 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 5498.25 kips
Vu= -246.30 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.045
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 74 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 13018.97 in2
Vc= 1426.16 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1212.23 kips
Vu= 9.24 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.008
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 74 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 14208.00 in2
Vc= 1556.41 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1322.95 kips
Vu= 28.08 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.021
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 74.1535 in.
w'= 6.500 in.
w'/d= 0.088 OK, this limit state should be checked
Vu= 3697.35 kips
Mu= 58402.86 k-in.
Vud/Mu= 4.694
Mu/(Vud)= 0.213
k= 10.000
fVc= 6073.74 kips
Vu/f Vc= 0.609
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 72.4605 in.
w'= 28.466 in.
w'/d= 0.393 OK, this limit state should be checked
Vu= 2422.32 kips
Mu= 68641.52 k-in.
Vud/Mu= 2.557
Mu/(Vud)= 0.391
k= 10.000
fVc= 6477.12 kips
Vu/f Vc= 0.374
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? OK
Long bar size small enough to develop hooks? OK
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2987.73 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 27.330 in.
Rounded Dimension c= 28 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 41 in.
d/2= 20.5 in.
No. of piles outside d/2 from face of the column = 4
4(fc')0.5= 219.09 psi
b0= 276 in.
Vc= 2479.21 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2107.33 kips
Vu= 1485.45 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.705
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 41 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 4278.73 in2
Vc= 468.71 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 398.40 kips
Vu= -1.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.004
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 41 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 4674.00 in2
Vc= 512.01 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 435.21 kips
Vu= 2.28 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.005
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 41.5 in.
w'= 7.000 in.
w'/d= 0.169 OK, this limit state should be checked
Vu= 1120.21 kips
Mu= 21204.60 k-in.
Vud/Mu= 2.192
Mu/(Vud)= 0.456
k= 10.000
fVc= 2016.32 kips
Vu/f Vc= 0.556
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 40.436 in.
w'= 20.176 in.
w'/d= 0.499 OK, this limit state should be checked
Vu= 1121.17 kips
Mu= 22654.21 k-in.
Vud/Mu= 2.001
Mu/(Vud)= 0.500
k= 9.473
fVc= 2033.09 kips
Vu/f Vc= 0.551
(continued)
Comments:
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 80 in. distance fro
d/2= 40 in. distance fro
No. of piles outside d/2 from face of the column = 0 distance fro
4(fc')0.5= 219.09 psi
b0= 532 in.
Vc= 9324.43 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face Limit State A
fVc= 7925.76 kips
Vu= -239.69 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.030
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 80 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi
bd= 15360.00 in2 Limit State A
0.5
Vc= 1682.60 kips based on Vc=2(fc') bd acting at d from column face
fVc= 1430.21 kips
Vu= 25.20 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.018
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 80 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi
bd= 15360.00 in2 Limit State A
0.5
Vc= 1682.60 kips based on Vc=2(fc') bd acting at d from column face
fVc= 1430.21 kips
Vu= 25.20 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.018
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 80.1535 in.
w'= 36.500 in.
w'/d= 0.455 OK, this limit state should be checked
Vu= 3673.20 kips
Mu= 134363.70 k-in.
Vud/Mu= 2.191 Limit State A
Mu/(Vud)= 0.456
k= 10.000
fVc= 7164.79 kips
Vu/f Vc= 0.513
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 78.4605 in.
w'= 36.5 in.
w'/d= 0.465 OK, this limit state should be checked
Vu= 3673.20 kips
Mu= 134363.70 k-in.
Vud/Mu= 2.145 Limit State A
Mu/(Vud)= 0.466
k= 10.000
fVc= 7013.45 kips
Vu/f Vc= 0.524
(continued)
Vu=
d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=
Vu=
Vu/f Vc=
d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 71 in.
d/2= 35.5 in.
No. of piles outside d/2 from face of the column = 2
4(fc')0.5= 219.09 psi
b0= 508 in.
Vc= 7902.10 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 6716.79 kips
Vu= 2242.68 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.334
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 71 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 12491.17 in2
Vc= 1368.34 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1163.09 kips
Vu= -53.44 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.046
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 71 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 17892.00 in2
Vc= 1959.97 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1665.97 kips
Vu= 31.28 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.019
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 71.1535 in.
w'= 5.000 in.
w'/d= 0.070 OK, this limit state should be checked
Vu= 4926.03 kips
Mu= 169695.71 k-in.
Vud/Mu= 2.065
Mu/(Vud)= 0.484
k= 10.000
fVc= 5828.01 kips
Vu/f Vc= 0.845
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 69.4605 in.
w'= 26.96 in.
w'/d= 0.388 OK, this limit state should be checked
Vu= 3670.00 kips
Mu= 98429.18 k-in.
Vud/Mu= 2.590
Mu/(Vud)= 0.386
k= 10.000
fVc= 8149.26 kips
Vu/f Vc= 0.450
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5413.79 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 36.789 in.
Rounded Dimension c= 37 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 53 in.
d/2= 26.5 in.
No. of piles outside d/2 from face of the column = 6
4(fc')0.5= 219.09 psi
b0= 360 in.
Vc= 4180.22 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3553.19 kips
Vu= 2924.66 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.823
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 53 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 6993.30 in2
Vc= 766.08 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 651.17 kips
Vu= -26.55 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.041
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 53 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 10017.00 in2
Vc= 1097.31 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 932.71 kips
Vu= 9.14 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.010
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 53.295 in.
w'= 7.000 in.
w'/d= 0.131 OK, this limit state should be checked
Vu= 2472.25 kips
Mu= 72185.65 k-in.
Vud/Mu= 1.825
Mu/(Vud)= 0.548
k= 10.000
fVc= 3273.95 kips
Vu/f Vc= 0.755
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 51.885 in.
w'= 23.4745 in.
w'/d= 0.452 OK, this limit state should be checked
Vu= 1969.49 kips
Mu= 46212.14 k-in.
Vud/Mu= 2.211
Mu/(Vud)= 0.452
k= 10.000
fVc= 4565.45 kips
Vu/f Vc= 0.431
(continued)
Comments:
Design Checks:
Short bar size small enough to develop hooks? NG; select smaller bar size
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? NG CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1442.16 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 18.988 in.
Rounded Dimension c= 19 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38 in.
d/2= 19 in.
No. of piles outside d/2 from face of the column = 10
4(fc')0.5= 219.09 psi
b0= 228 in.
Vc= 1898.19 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1613.46 kips
Vu= 1207.82 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.749
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 109.54 psi
bd= 3876.00 in2
Vc= 424.59 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 360.91 kips
Vu= 369.38 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 1.023
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 5244.00 in2
Vc= 574.45 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 488.28 kips
Vu= -3.22 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.007
(continued)
d/2= 19 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.365 in.
w'= 11.500 in.
w'/d= 0.300 OK, this limit state should be checked
Vu= 727.54 kips
Mu= 21452.32 k-in.
Vud/Mu= 1.301
Mu/(Vud)= 0.769
k= 10.000
fVc= 1821.86 kips
Vu/f Vc= 0.399
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 37.355 in.
w'= 29.5 in.
w'/d= 0.790 OK, this limit state should be checked
Vu= 473.82 kips
Mu= 14311.77 k-in.
Vud/Mu= 1.237
Mu/(Vud)= 0.809
k= 3.789
fVc= 909.28 kips
Vu/f Vc= 0.521
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 4838.91 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 34.781 in.
Rounded Dimension c= 35 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48 in.
d/2= 24 in.
No. of piles outside d/2 from face of the column = 6
4(fc')0.5= 219.09 psi
b0= 332 in.
Vc= 3491.40 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2967.69 kips
Vu= 2206.40 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.743
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 5472.00 in2
Vc= 599.43 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 509.51 kips
Vu= -16.39 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.032
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 8001.79 in2
Vc= 876.55 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 745.07 kips
Vu= 11.41 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.015
(continued)
d/2= 24 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.365 in.
w'= 16.676 in.
w'/d= 0.345 OK, this limit state should be checked
Vu= 1859.53 kips
Mu= 65941.50 k-in.
Vud/Mu= 1.364
Mu/(Vud)= 0.733
k= 9.845
fVc= 2527.25 kips
Vu/f Vc= 0.736
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.23 in.
w'= 3.5 in.
w'/d= 0.074 OK, this limit state should be checked
Vu= 1866.96 kips
Mu= 26408.38 k-in.
Vud/Mu= 3.339
Mu/(Vud)= 0.299
k= 10.000
fVc= 3665.59 kips
Vu/f Vc= 0.509
(continued)
Comments:
cb= 3 in.
ld= 40.499 in. yt=
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 60 in. distance fro
d/2= 30 in. distance fro
No. of piles outside d/2 from face of the column = 10 distance fro
4(fc')0.5= 219.09 psi distance fro
b0= 396 in. distance fro
0.5
Vc= 5205.56 kips based on Vc=4(fc') b0d acting at d/2 from column face distance fro
fVc= 4424.72 kips
Vu= 4335.33 kips reduced by weight of concrete outside of critical section Limit State A
Vu/f Vc= 0.980
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 60 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi distance fro
bd= 9141.12 in2 distance fro
Vc= 1001.36 kips based on Vc=2(fc')0.5bd acting at d from column face Limit State A
fVc= 851.16 kips
Vu= -2.22 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.003
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 60 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi distance fro
bd= 9720.00 in2 Limit State A
Vc= 1064.77 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 905.06 kips
Vu= 5.24 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.006
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 60.365 in.
w'= 1.500 in.
w'/d= 0.025 OK, this limit state should be checked
Vu= 2596.91 kips
Mu= 49614.87 k-in.
Vud/Mu= 3.160 Limit State A
Mu/(Vud)= 0.316
k= 10.000
fVc= 4281.67 kips
Vu/f Vc= 0.607
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 59.166 in.
w'= 1.5 in.
w'/d= 0.025 OK, this limit state should be checked
Vu= 3046.74 kips
Mu= 44607.18 k-in.
Vud/Mu= 4.041 Limit State A
Mu/(Vud)= 0.247
k= 10.000
fVc= 4462.38 kips
Vu/f Vc= 0.683
(continued)
Vu=
d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=
Vu=
Vu/f Vc=
d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 1791.35 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 21.162 in.
Rounded Dimension c= 22 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 38 in.
d/2= 19 in.
No. of piles outside d/2 from face of the column = 14
4(fc')0.5= 219.09 psi
b0= 240 in.
Vc= 1998.09 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1698.38 kips
Vu= 1687.35 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.994
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 38 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 4638.55 in2
Vc= 508.13 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 431.91 kips
Vu= 236.75 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.548
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 38 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 5308.00 in2
Vc= 581.46 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 494.24 kips
Vu= 242.21 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.490
(continued)
d/2= 19 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 38.295 in.
w'= 23.176 in.
w'/d= 0.605 OK, this limit state should be checked
Vu= 713.79 kips
Mu= 24187.92 k-in.
Vud/Mu= 1.130
Mu/(Vud)= 0.885
k= 4.284
fVc= 1053.90 kips
Vu/f Vc= 0.677
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 36.885 in.
w'= 10 in.
w'/d= 0.271 OK, this limit state should be checked
Vu= 843.02 kips
Mu= 23769.63 k-in.
Vud/Mu= 1.308
Mu/(Vud)= 0.764
k= 10.000
fVc= 2656.63 kips
Vu/f Vc= 0.317
(continued)
Comments:
cb= 2 in.
ld= 42.438 in. yt=
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 61 in. distance fro
d/2= 30.5 in. distance fro
No. of piles outside d/2 from face of the column = 12 distance fro
4(fc')0.5= 219.09 psi distance fro
b0= 400 in. distance fro
0.5
Vc= 5345.77 kips based on Vc=4(fc') b0d acting at d/2 from column face Limit State A
fVc= 4543.91 kips
Vu= 4484.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.987
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 61 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi distance fro
bd= 9150.00 in2 Limit State A
Vc= 1002.33 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 851.98 kips
Vu= 8.14 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.010
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 61 in. distance fro
No. of piles outside d from face of the column = 0 distance fro
2(fc')0.5= 109.54 psi distance fro
bd= 9150.00 in2 Limit State A
Vc= 1002.33 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 851.98 kips
Vu= 8.14 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.010
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 61.436 in.
w'= 1.500 in.
w'/d= 0.024 OK, this limit state should be checked
Vu= 2989.91 kips
Mu= 57625.90 k-in.
Vud/Mu= 3.188 Limit State A
Mu/(Vud)= 0.314
k= 10.000
fVc= 4290.36 kips
Vu/f Vc= 0.697
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 60.308 in.
w'= 1.5 in.
w'/d= 0.025 OK, this limit state should be checked
Vu= 2989.91 kips
Mu= 57625.90 k-in.
Vud/Mu= 3.129 Limit State A
Mu/(Vud)= 0.320
k= 10.000
fVc= 4211.59 kips
Vu/f Vc= 0.710
(continued)
Vu=
d=
d/2=
Length dime
Area in shea
4(fc')0.5=
Vc=
Vu=
Vu/f Vc=
d=
dcritical=
diagonal =
Area in shea
2(fc')0.5=
Vc=
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2039.31 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 22.579 in.
Rounded Dimension c= 23 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 41 in.
d/2= 20.5 in.
No. of piles outside d/2 from face of the column = 16
4(fc')0.5= 219.09 psi
b0= 256 in.
Vc= 2299.56 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 1954.62 kips
Vu= 1940.32 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.993
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 41 in.
No. of piles outside d from face of the column = 3
0.5
2(fc') = 109.54 psi
bd= 4839.04 in2
Vc= 530.09 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 450.58 kips
Vu= 366.97 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.814
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 41 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 5229.96 in2
Vc= 572.91 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 486.98 kips
Vu= 245.18 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.503
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 41.295 in.
w'= 22.676 in.
w'/d= 0.549 OK, this limit state should be checked
Vu= 838.90 kips
Mu= 30629.76 k-in.
Vud/Mu= 1.131
Mu/(Vud)= 0.884
k= 4.728
fVc= 1254.28 kips
Vu/f Vc= 0.669
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 39.955 in.
w'= 9.5 in.
w'/d= 0.238 OK, this limit state should be checked
Vu= 840.26 kips
Mu= 23270.87 k-in.
Vud/Mu= 1.443
Mu/(Vud)= 0.693
k= 10.000
fVc= 2877.74 kips
Vu/f Vc= 0.292
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5558.57 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 37.278 in.
Rounded Dimension c= 38 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48 in.
d/2= 24 in.
No. of piles outside d/2 from face of the column = 10
4(fc')0.5= 219.09 psi
b0= 344 in.
Vc= 3617.60 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3074.96 kips
Vu= 3058.14 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.995
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 7200.00 in2
Vc= 788.72 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 670.41 kips
Vu= -19.76 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.029
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 8001.79 in2
Vc= 876.55 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 745.07 kips
Vu= -10.74 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.014
(continued)
d/2= 24 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.365 in.
w'= 15.176 in.
w'/d= 0.314 OK, this limit state should be checked
Vu= 2162.24 kips
Mu= 71397.56 k-in.
Vud/Mu= 1.465
Mu/(Vud)= 0.683
k= 10.000
fVc= 3377.55 kips
Vu/f Vc= 0.640
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.166 in.
w'= 2 in.
w'/d= 0.042 OK, this limit state should be checked
Vu= 2484.80 kips
Mu= 49094.34 k-in.
Vud/Mu= 2.387
Mu/(Vud)= 0.419
k= 10.000
fVc= 3660.62 kips
Vu/f Vc= 0.679
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column
Net Column
CapacityCapacity
Pu= Pu= 2261.90 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Minimum Columumn Dimension c= 23.780 in.
Rounded Dimen ded Dimension c= 24 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 44 in.
d/2= 22 in.
No. of piles outside d/2 from face of the column = 18
4(fc')0.5= 219.09 psi
b0= 272 in.
Vc= 2622.06 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2228.75 kips
Vu= 2168.58 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.973
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 44 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 6072.00 in2
Vc= 665.15 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 565.38 kips
Vu= 484.91 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.858
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 44 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 7231.49 in2
Vc= 792.17 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 673.34 kips
Vu= 495.98 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.737
(continued)
d/2= 22 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 44.295 in.
w'= 22.176 in.
w'/d= 0.501 OK, this limit state should be checked
Vu= 951.37 kips
Mu= 38591.71 k-in.
Vud/Mu= 1.092
Mu/(Vud)= 0.916
k= 4.858
fVc= 1382.58 kips
Vu/f Vc= 0.688
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 42.955 in.
w'= 9 in.
w'/d= 0.210 OK, this limit state should be checked
Vu= 1081.74 kips
Mu= 29101.58 k-in.
Vud/Mu= 1.597
Mu/(Vud)= 0.626
k= 10.000
fVc= 3286.76 kips
Vu/f Vc= 0.329
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 6132.63 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 39.156 in.
Rounded Dimension c= 40 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 59 in.
d/2= 29.5 in.
No. of piles outside d/2 from face of the column = 14
4(fc')0.5= 219.09 psi
b0= 396 in.
Vc= 5118.80 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 4350.98 kips
Vu= 4306.55 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.990
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 59 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 8850.00 in2
Vc= 969.47 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 824.05 kips
Vu= -20.13 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.024
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 59 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 10974.00 in2
Vc= 1202.14 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1021.82 kips
Vu= 7.13 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.007
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 59.295 in.
w'= 19.000 in.
w'/d= 0.320 OK, this limit state should be checked
Vu= 2455.06 kips
Mu= 90889.78 k-in.
Vud/Mu= 1.602
Mu/(Vud)= 0.624
k= 10.000
fVc= 4140.84 kips
Vu/f Vc= 0.593
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 58.026 in.
w'= 1 in.
w'/d= 0.017 OK, this limit state should be checked
Vu= 3101.96 kips
Mu= 58103.97 k-in.
Vud/Mu= 3.098
Mu/(Vud)= 0.323
k= 10.000
fVc= 5024.76 kips
Vu/f Vc= 0.617
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 3152.18 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 28.072 in.
Rounded Dimension c= 29 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 50 in.
d/2= 25 in.
No. of piles outside d/2 from face of the column = 12
4(fc')0.5= 219.09 psi
b0= 316 in.
Vc= 3461.61 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2942.37 kips
Vu= 1764.18 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.600
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 50 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 7024.67 in2
Vc= 769.51 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 654.09 kips
Vu= 624.43 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.955
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 50 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 8217.60 in2
Vc= 900.19 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 765.16 kips
Vu= 304.43 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.398
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 50.295 in.
w'= 6.500 in.
w'/d= 0.129 OK, this limit state should be checked
Vu= 1355.95 kips
Mu= 46866.92 k-in.
Vud/Mu= 1.455
Mu/(Vud)= 0.687
k= 10.000
fVc= 3848.39 kips
Vu/f Vc= 0.352 **CONTROLLING** Vu/f Vc= 0.352
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 48.885 in.
w'= 6.5 in.
w'/d= 0.133 OK, this limit state should be checked
Vu= 1355.95 kips
Mu= 44325.28 k-in.
Vud/Mu= 1.495
Mu/(Vud)= 0.669
k= 10.000
fVc= 3740.50 kips
Vu/f Vc= 0.363 **CONTROLLING** Vu/f Vc= 0.363
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5386.54 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 36.697 in.
Rounded Dimension c= 37 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 52 in.
d/2= 26 in.
No. of piles outside d/2 from face of the column = 14
4(fc')0.5= 219.09 psi
b0= 356 in.
Vc= 4055.78 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3447.41 kips
Vu= 3406.75 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.988
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 52 in.
No. of piles outside d from face of the column = 2
2(fc')0.5= 109.54 psi
bd= 7880.50 in2
Vc= 863.27 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 733.78 kips
Vu= 490.47 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.668
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 52 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 7648.68 in2
Vc= 837.87 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 712.19 kips
Vu= -9.81 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.014
(continued)
d/2= 26 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 52.295 in.
w'= 2.500 in.
w'/d= 0.048 OK, this limit state should be checked
Vu= 2463.83 kips
Mu= 67833.62 k-in.
Vud/Mu= 1.899
Mu/(Vud)= 0.526
k= 10.000
fVc= 4058.69 kips
Vu/f Vc= 0.607 **CONTROLLING** Vu/f Vc= 0.607
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 50.885 in.
w'= 15.676 in.
w'/d= 0.308 OK, this limit state should be checked
Vu= 2210.90 kips
Mu= 65404.36 k-in.
Vud/Mu= 1.720
Mu/(Vud)= 0.581
k= 10.000
fVc= 4406.38 kips
Vu/f Vc= 0.502 **CONTROLLING** Vu/f Vc= 0.50175
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? NA CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 2730.16 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 26.125 in.
Rounded Dimension c= 27 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 48 in.
d/2= 24 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 219.09 psi
b0= 300 in.
Vc= 3154.88 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 2681.65 kips
Vu= 2647.48 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.987
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 48 in.
No. of piles outside d from face of the column = 3
2(fc')0.5= 109.54 psi
bd= 7888.90 in2
Vc= 864.19 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 734.56 kips
Vu= 358.50 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.488
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 48 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 7161.42 in2
Vc= 784.49 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 666.82 kips
Vu= 491.28 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.737
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 48.295 in.
w'= 7.500 in.
w'/d= 0.155 OK, this limit state should be checked
Vu= 1190.96 kips
Mu= 43539.89 k-in.
Vud/Mu= 1.321
Mu/(Vud)= 0.757
k= 10.000
fVc= 3695.36 kips
Vu/f Vc= 0.322 **CONTROLLING** Vu/f Vc= 0.322
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 46.885 in.
w'= 25.5 in.
w'/d= 0.544 OK, this limit state should be checked
Vu= 1064.00 kips
Mu= 42595.78 k-in.
Vud/Mu= 1.171
Mu/(Vud)= 0.854
k= 5.064
fVc= 1923.21 kips
Vu/f Vc= 0.553 **CONTROLLING** Vu/f Vc= 0.553
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5843.32 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 38.221 in.
Rounded Dimension c= 39 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 56 in.
d/2= 28 in.
No. of piles outside d/2 from face of the column = 16
4(fc')0.5= 219.09 psi
b0= 380 in.
Vc= 4662.21 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 3962.88 kips
Vu= 3878.05 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.979
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 56 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 9875.71 in2
Vc= 1081.83 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 919.56 kips
Vu= -28.29 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.031
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 56 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 10416.00 in2
Vc= 1141.02 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 969.86 kips
Vu= -21.61 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.022
(continued)
d/2= 28 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 56.295 in.
w'= 1.500 in.
w'/d= 0.027 OK, this limit state should be checked
Vu= 2441.18 kips
Mu= 82417.47 k-in.
Vud/Mu= 1.667
Mu/(Vud)= 0.600
k= 10.000
fVc= 4622.00 kips
Vu/f Vc= 0.528
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 54.955 in.
w'= 14.676 in.
w'/d= 0.267 OK, this limit state should be checked
Vu= 2442.91 kips
Mu= 79629.83 k-in.
Vud/Mu= 1.686
Mu/(Vud)= 0.593
k= 10.000
fVc= 4758.82 kips
Vu/f Vc= 0.513
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? NA
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 4697.99 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 34.271 in.
Rounded Dimension c= 35 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 58 in.
d/2= 29 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 219.09 psi
b0= 372 in.
Vc= 4727.06 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 4018.01 kips
Vu= 4011.67 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.998
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 58 in.
No. of piles outside d from face of the column = 4
2(fc')0.5= 109.54 psi
bd= 8598.60 in2
Vc= 941.93 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 800.64 kips
Vu= 745.06 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.931
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 58 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 10201.15 in2
Vc= 1117.48 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 949.86 kips
Vu= -11.02 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.012
(continued)
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 58.295 in.
w'= 3.500 in.
w'/d= 0.060 OK, this limit state should be checked
Vu= 2377.75 kips
Mu= 82358.86 k-in.
Vud/Mu= 1.683
Mu/(Vud)= 0.594
k= 10.000
fVc= 4722.37 kips
Vu/f Vc= 0.504 **CONTROLLING** Vu/f Vc= 0.504
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 56.885 in.
w'= 3.5 in.
w'/d= 0.062 OK, this limit state should be checked
Vu= 2188.51 kips
Mu= 59774.38 k-in.
Vud/Mu= 2.083
Mu/(Vud)= 0.480
k= 10.000
fVc= 5050.53 kips
Vu/f Vc= 0.433 **CONTROLLING** Vu/f Vc= 0.433
(continued)
Comments:
Design Checks:
Short bar size small enough to develop straight bars? OK
Long bar size small enough to develop straight bars? NG; select smaller bar size
CRSI Limit State 1 Adequate? OK
CRSI Limit State 2 Adequate? OK CRSI Limit State P1 Adequate? OK
CRSI Limit State 3 Adequate? OK CRSI Limit State P2 Adequate? OK
CRSI Limit State 4 Adequate? OK CRSI Limit State P3 Adequate? OK
CRSI Limit State 5 Adequate? OK CRSI Limit State P4 Adequate? OK
CRSI Limit State 6 Adequate? OK
Results:
Column Size Determination
Net Column Capacity Pu= 5062.61 kips (reduced by 1.6 x pile cap wt., column f'c = 4 ksi)
Min. Column Dimension c= 35.576 in.
Rounded Dimension c= 36 in.
(continued)
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 58 in.
d/2= 29 in.
No. of piles outside d/2 from face of the column = 22
4(fc')0.5= 219.09 psi
b0= 376 in.
Vc= 4777.89 kips based on Vc=4(fc')0.5b0d acting at d/2 from column face
fVc= 4061.21 kips
Vu= 3994.06 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.983
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 58 in.
No. of piles outside d from face of the column = 5
2(fc')0.5= 109.54 psi
bd= 10092.00 in2
Vc= 1105.52 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 939.69 kips
Vu= 928.20 kips reduced by weight of concrete outside of critical section
Vu/f Vc= 0.988
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 58 in.
No. of piles outside d from face of the column = 0
2(fc')0.5= 109.54 psi
bd= 11060.83 in2
Vc= 1211.65 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 1029.91 kips
Vu= -19.81 kips reduced by weight of concrete outside of critical section
Vu/f Vc= -0.019
(continued)
d/2= 29 in.
Check deep beam (one way shear through short width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 58.295 in.
w'= 3.000 in.
w'/d= 0.051 OK, this limit state should be checked
Vu= 2560.88 kips
Mu= 86948.78 k-in.
Vud/Mu= 1.717
Mu/(Vud)= 0.582
k= 10.000
fVc= 4722.37 kips
Vu/f Vc= 0.542
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 56.955 in.
w'= 3 in.
w'/d= 0.053 OK, this limit state should be checked
Vu= 2179.72 kips
Mu= 71744.50 k-in.
Vud/Mu= 1.730
Mu/(Vud)= 0.578
k= 10.000
fVc= 5056.75 kips
Vu/f Vc= 0.431
(continued)
Comments:
cb = 3 in.
ld= 51.600 in. y t=
lavailable= 69.000 in. OK; sufficient length available to develop bar ye=
Req. number of short bars = 21.47 ys=
Prov. number of short bars = 33 (cb+Ktr)/db=
ld=
(continued)
Check two way shear at a distance d/2 from column - CRSI LIMIT STATE 1 -
d= 49 in. distance from
d/2= 24.5 in. distance from
No. of piles outside d/2 from face of the column = 24 distance from
4(fc')0.5= 219.09 psi distance from
b 0= 316 in. distance from
0.5
Vc= 3392.37 kips based on Vc=4(fc') b0d acting at d/2 from column face distance from
f Vc= 2883.52 kips
Vu= 2823.72 kips reduced by weight of concrete outside of critical section Limit State Al
Vu/f Vc= 0.979
Check deep beam (one way shear through short width) at a distance
d from column face - CRSI LIMIT STATE 2 -
d= 49 in. distance from
No. of piles outside d from face of the column = 5 distance from
2(fc')0.5= 109.54 psi distance from
bd= 8526.00 in2 distance from
Vc= 933.98 kips based on Vc=2(fc')0.5bd acting at d from column face
fVc= 793.88 kips
Vu= 581.54 kips reduced by weight of concrete outside of critical section Limit State Al
Vu/f Vc= 0.733
Check deep beam (one way shear through long width) at a distance
d from column face - CRSI LIMIT STATE 3 -
d= 49 in. distance from
No. of piles outside d from face of the column = 6 distance from
2(fc')0.5= 109.54 psi distance from
bd= 10290.00 in2
(continued)
Check two way shear at column face - CRSI LIMIT STATE 4 - waverage
d= 49 in. Make sure lar
d/2= 24.5 in. NG, but answ
No. of piles outside face of the column = 30 32(fc')0.5=
wactual= 6.000 in. < d/2 This procedure applies ###
Vu= 3547.95 kips ###
0.5
4(fc') = 219.09 psi 4(fc')0.5=
32(fc')0.5= 1752.71 psi 32(fc')0.5=
b 0= 316.000 in. b0=
b s= 120.000 in. Limit State Al
k= 32.000 based on k=2(d/w)(1+d/c) acting at column face k=
Vc= 10305.95 kips based on Vc=k(fc')0.5bsd acting at column face ###
fVc= 8760.06 kips ###
Vu/f Vc= 0.405 ****COMBINED**** Vu/f Vc= 0.80516 ###
Check deep beam (one way shear through short width) at face of column ###
(only applies when w/d<1.0) - CRSI LIMIT STATE 5 -
d= 49.295 in. Limit State Al
w'= 6.000 in. w'=
w'/d= 0.122 OK, this limit state should be checked w'/d=
Vu= 1791.68 kips Vu=
Mu= 74865.38 k-in. M u=
Vud/Mu= 1.180 Vud/Mu=
Mu/(Vud)= 0.848 Mu/(Vud)=
k= 10.000 k=
fVc= 3993.30 kips
Vu/f Vc= 0.449 **CONTROLLING** Vu/f Vc= 0.449
Check deep beam (one way shear through long width) at face of column
(only applies when w/d<1.0) - CRSI LIMIT STATE 6 -
d= 47.885 in. Limit State Al
w'= 24 in. w'=
w'/d= 0.501 OK, this limit state should be checked w'/d=
Vu= 1412.10 kips Vu=
Mu= 60051.60 k-in. M u=
Vud/Mu= 1.126 Vud/Mu=
Mu/(Vud)= 0.888 Mu/(Vud)=
k= 5.139 k=
fVc= 2405.88 kips
Vu/f Vc= 0.587 **CONTROLLING** Vu/f Vc= 0.587
(continued)
Vu=
d=
d/2=
Length dimen
Area in shear
4(fc')0.5=
Vc=
Vu=
Vu/f Vc=
d=
dcritical=
diagonal =
Area in shear
2(fc')0.5=
Vc=