You are on page 1of 2

SLK60P6L 220Wp - 255 Wp

Poly-Crystalline Solar Modules


Real World Tested • Globally Trusted

ASSOCIATION Why Siliken?


Our global success has established a solid foundation to service

the long-term needs of the solar industry.

With over 300 MW installed worldwide, we have built a respected

brand by consistently providing a quality product with proven

performance.

Our firm commitment to R&D allows us to reduce costs and perma­


IS O 9

1:2
00

000
Nº ES08/5170

nently improve efficiency. What’s more, it enables us to improve

our existing products and develop new technologies in the renewable


Nº ES09/6520
energy sector.
w. t u v. c o
w
m
II II I III I w

• Periodic inspection
I II III I II I

• Qualified, IEC 61215


TÜVRheiland
II I II

• Safety Tested, IEC 61730


II I I

D 3
: 00
5

000223
I

25 year
Linear
Power
Guarantee

• Excellent Power Tolerance +3/0 %


Siliken Reliability
• 10 Year Limited Warranty Product
The Siliken modules are certified according to UL and IEC standards.
• 25 Year Linear Power Guarantee The high quality and reliability ensure the prompt return of investment

• Outstanding Low-Light Performance for any PV installation, including residential, commercial or utility scale.

• UL, TÜV and Intertek Certified for Worldwide Each module goes through its testing phases, including strict power

Applications production verification and resistance tests in radiation simulators. With

innovative products and solutions successfully implemented around


• High Performance Modules with Efficiency up
the world, Siliken is a recognized global leader in solar power.
to 15,7%
• Carbon Friendly

The Siliken module is rated first by Photon Laboratory


for long term energy production. It generates 5.9%
more power than the average value of all the modules
studied and 12.4% more than the minimum value
recorded.

Siliken S.A. · Ronda Isaac Peral y Caballero, 14 · 46980 Paterna - Valencia - Spain · Tel.: (+34) 902 41 22 33 · Fax: (+34) 96 070 92 65 · info@siliken.com · www.siliken.com
SLK60P6L 220Wp - 255 Wp
Poly-Crystalline Solar Modules

1640

40

Constructive Characteristics
12,5 x 8,5
Dimensions of the
8 anchoring drill holes
1 FRAME 1

Center hole distance


GND 2
2 GLASS PLATE
3
990

950
3 & 5 EVA
1000
4
4 CELLS
Junction Box IP 65 5
6 BACKSIDE FOIL
6

Tolerance ±2 mm
Voc: 36,9 V DC (±3%)
Módulo Fotovoltáico Estándar
Standard Photovoltaic Module

This unit may produce electricity when

Nameplate
exposed to light. Cover active surface

GND
Isc: 8,28 A (±3%)

Nº. Serie / Serial Number

*00568519*

*00568519*
For Field connections, use minimum No. 10 AWG copper wires insulated for

before handling junction box. When

modules, hazardous voltage maybe


minimum of 90ºC (194ºF). Class C fire rating, as determined after UL flame
sist: 1000 V DC

handling the photovoltaic module.

21109301K8
Electrical values under estándar conditions, according IEC 60904

produced. Read completely and


carefully the user's guide before
Valores eléctricos bajo condiciones estándar, según IEC 60904
FF: 75,28%

connected in series with other


Warning!

29
Vmax

92.94 W/ft2, 77ºF and AM1.5


1000 W/m2, 25ºC y AM1.5

Web: www.siliken.com, e-Mail: info@siliken.com


test. Maximum series fuse rated 10 DC Amps.

Peso / Weight: 19,00 Kgs / 41,89 lbs


Mod.: SLK60P6L 230W 5%

21109301K8
detenidamente antes de manipular el
área activa para manipular la caja de

serie con otros módulos se alcanzan


valores de tensión peligrosos. Lea el
cuando se expone a la luz. Cubrir el

conexiones. Cuando se conecta en

Fabricado por / Manufactured by


¡Precaución!
Este módulo produce electricidad

manual de instrucciones entera y


Vmpp: 29,5 V DC (±3%)
Pmpp: 230,0 Wp (±5%)

7,79 A (±3%)

Dim.: 1640x990x40

QC OK

Siliken Modules S.L.U.


Tk(Pn): -0.43%/ºC
NOCT: 46±2ºC

módulo fotovoltáico.
P/N: 012381

CIF: B-97744866

Units in mm
7 JUNCTION BOX 7
Impp:

012381

330 490 490 330

SLK60P6L - 225 Wp SLK60P6L - 225 Wp Weak light performance at Pmpp


I-V and Pmax characteristics with a variety of radiation levels at 25ºC I-V characteristics with a variety of cell temperatures at 1.000 W/m2 Siliken module's average

8,5 220 9 100%


8,0
200
7,5 8 98%
7,0 180
6,5 7
96%
160
Pmpp/Pmpp stc

6,0
5,5 6
140
Current (A)

Current (A)

94%
Power(W)

5,0
4,5 120 5
92%
4,0 100 4
3,5
80 90%
3,0 3
2,5 60
2,0 88%
2
1,5 40
1,0 1 86%
20
0,5
0,0 0 0 84%
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 0 5 10 15 20 25 30 35 200 300 400 500 600 700 800 900 1000

Voltage (V) Voltage (V) Radiation (W/m2)

Mechanical Data Certifications


Dimensions (LxWxD) 1640 x 990 x 40 mm UL Listed and UL ORD-C1703-01 / UL1703
Weight 19 kg Intertek
Output Cables Symmetrical length cable 1 m Ø4 mm2, double insulation coating, halogen free, UV resistance Fire Rating Class C
Junction Box IP-65 rated with bypass diodes TÜV Certified IEC 61215 / IEC 61730 / 61701 Salt Mist Corrosion
Frame Anodized aluminum of 15 microns thickness type 6063 T6 ISO 9001:2000 Nº ES08/5170
Front Glass 3,2 mm low iron tempered glass with high transmissivity ISO 14001 Nº ES09/6520
Solar Cells 60 Poly-crystalline cells 156 x 156 mm EC Declaration of conformity (CE Mark)
MCS United Kingdom
Electrical Data
Tested Operating Conditions
Maximum power at STC (+3/0 %) Pmp (Wp) 220* 225* 230 235 240 245 250* 255*
Efficency at STC (%) 13,6 13,9 14,2 14,5 14,8 Temperature -40 ºC to +85 ºC
15,1 15,4 15,7
Fill Factor FF 0,740 0,746 0,749 0,752 0,753 Static Load 2400 Pa
0,757 0,756 0,762
Voltage at Maximum Power Vmp (V) 29,2 29,3 29,5 29,5 29,6 Max Load 5400 Pa
29,6 29,8 29,8
Current at Maximum Power Imp (A) Impact Resistance Hailstone impact Ø25 mm at 23 m/s
7,54 7,68 7,79 7,97 8,12 8,27 8,39 8,56
Open Circuit Voltage Voc (V) 36,7 36,8 36,9 36,9 37,0 37,0 37,1 37,1 Product Warranty
Short Circuit Current Isc (A) 8,10 8,20 8,32 8,47 8,61 8,75 8,91 9,02
10 year limited warranty on materials and workmanship
Maximum Voltage UL / IEC Vmax (V) UL/IEC 600 / 1000
Temperature Coefficient of Pmp TkPmp (%/ºC) -0,43 25 Year Linear Power Guarantee
Temperature Coefficient of Voc TkVoc (%/ºC) -0,356
Year 1: 97% of rated output
Temperature Coefficient of Isc TkIsc (%/ºC) +0,062
Years 2-25: 0.7% p.a. reduction
Normal Operating Cell Temperature NOCT (ºC) 46±2
Series Fuse Rating A 11
Bypass Diodes A/V 12/40 C/ Massamagrell, 13 • Pol. Ind L’Horteta.
Reverse current test A 13,5 46138 Rafelbunyol - Valencia - Spain
M a y 20 1 1

Values at Standard Test Conditions STC: Irradiance 1.000 W/m2, Air Mass AM 1,5 and cell temperature 25ºC.
* Subject to availability. WARNING: Read the instruction manual carefully before using this product
NOTE: Siliken Manufacturing, S.L.U. reserves the right to modify this product without prior notice

Siliken S.A. · Ronda Isaac Peral y Caballero, 14 · 46980 Paterna - Valencia - Spain · Tel.: (+34) 902 41 22 33 · Fax: (+34) 96 070 92 65 · info@siliken.com · www.siliken.com

You might also like