Designation: B 32 – 96 An American National Standard

AMERICAN SOCIETY FOR TESTING AND MATERIALS


100 Barr Harbor Dr., West Conshohocken, PA 19428
Reprinted from the Annual Book of ASTM Standards. Copyright ASTM

Standard Specification for


Solder Metal1
This standard is issued under the fixed designation B 32; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript
epsilon (e) indicates an editorial change since the last revision or reapproval.

This standard has been approved for use by agencies of the Department of Defense.

1. Scope Determine Conformance with Specifications3


1.1 This specification covers solder metal alloys (commonly E 46 Test Methods for Chemical Analysis of Lead- and
known as soft solders), including tin-lead, tin-antimony, tin- Tin-Base Solder4
antimony-copper-silver, tin-antimony-coppersilver-nickel, tin- E 51 Method for Spectrographic Analysis of Tin Alloys by
silver, tin-copper-silver, and lead-tin-silver, used for the pur- the Powder Technique5
pose of joining together two or more metals at temperatures E 55 Practice for Sampling Wrought Nonferrous Metals and
below their melting points. Alloys for Determination of Chemical Composition4
1.1.1 These solders include those alloys having a liquidus E 87 Methods for Chemical Analysis of Lead, Tin, Anti-
temperature not exceeding 800°F (430°C). mony, and Their Alloys (Photometric Method)6
1.1.2 This specification includes solders in the form of solid E 88 Practice for Sampling Nonferrous Metals and Alloys
bars, ingots, powder and special forms, and in the form of solid in Cast Form for Determination of Chemical Composition4
and flux-core ribbon, wire, and solder paste. 2.2 Federal Standard:
1.2 The values stated in inch-pound units are to be regarded Fed. Std. No. 123 Marking for Shipment (Civil Agencies)7
as the standard. The values given in parentheses are for 2.3 Military Standard:
information only. MIL-STD-129 Marking for Shipment and Storage7
1.3 The following precautionary caveat pertains only to the
test method portion, Section 13, of this specification: This 3. Terminology
standard does not purport to address all of the safety concerns,
if any, associated with its use. It is the responsibility of the user 3.1 Definition:
of this standard to establish appropriate safety and health 3.1.1 producer,, n—the primary manufacturer of the mate-
practices and determine the applicability of regulatory limita- rial.
tions prior to use. For specific precautionary statement, see 3.2 Definitions of Terms Specific to This Standard:
13.3.5. 3.2.1 lot,, n—The term “lot” as used in this specification is
defined as follows:
2. Referenced Documents
3.2.1.1 Discussion—For solid solder metal, a lot consists of
2.1 ASTM Standards: all solder of the same type designation, produced from the
D 269 Test Method for Insoluble Matter in Rosin and Rosin same batch of raw materials under essentially the same
Derivatives2 conditions, and offered for inspection at one time.
D 464 Test Methods for Saponification Number of Naval 3.2.1.2 Discussion—For flux–core solder, a lot consists of
Store Products Including Tall Oil and Other Related all solder of the same core mixture, produced from the same
Products2 batch of raw materials under essentially the same conditions
D 465 Test Methods for Acid Number of Naval Stores and offered for inspection at one time.
Products Including Tall Oil and Other Related Products2
3.2.2 lot number,, n—The term “lot number” as used in this
D 509 Test Methods of Sampling and Grading Rosin2
specification refers to a numerical designation for a lot which
E 28 Test Method for Softening Point by Ring-and-Ball
is traceable to a date of manufacture.
Apparatus2
E 29 Practice for Using Significant Digits in Test Data to
1 3
This specification is under the jurisdiction of ASTM Committee B-2 on Annual Book of ASTM Standards, Vol 14.02.
4
Nonferrous Metals and Alloys and is the direct responsibility of Subcommittee Annual Book of ASTM Standards, Vol 03.05.
5
B02.02 on Refined Lead, Tin, Antimony, and Their Alloys. Discontinued—See 1984 Annual Book of ASTM Standards, Vol 03.06.
6
Current edition approved May 10, 1996. Published June 1996. Originally Discontinued—See 1984 Annual Book of ASTM Standards, Vol 03.05.
7
published as B 32 – 19 T. Last previous edition B 32 – 95b. Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700
2
Annual Book of ASTM Standards, Vol 06.03. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.

1
B 32
4. Classification TABLE 2 Flux Type

4.1 Type Designation—The type designation uses the fol- Symbol Description

lowing symbols to properly identify the material: S Solid, no flux


R Rosin, nonactivated
4.1.1 Alloy Composition—The composition is identified by RMA Rosin, mildly activated
a two-letter symbol and a number. The letters typically indicate RA Rosin, activated
the chemical symbol for the critical element in the solder and OA Organic, water-soluble
OS Organic, organic solvent-soluble (other than R, RMA, or RA)
the number indicates the nominal percentage, by weight, of the IS Inorganic acids and salts
critical element in the solder. The designation followed by the
letters A or B distinguishes between different alloy grades of
similar composition (see Table 5). TABLE 3 Core Condition and Flux Percentage
4.1.2 Form—The form is indicated by a single letter in Condition
Condition
Symbol
accordance with Table 1.
4.1.3 Flux Type—The flux type is indicated by a letter or D Dry powder
P Plastic
combination of letters in accordance with Table 2.
Percentage
4.1.4 Core Condition and Flux Percentage (applicable only Symbol
Flux Percentage by Weight
to flux-cored solder)—The core condition and flux percentage
Nominal Min Max
is identified by a single letter and a number in accordance with 1 1.1 0.8 1.5
Table 3. 2 2.2 1.6 2.6
4.1.5 Powder Mesh Size and Flux Percentage (applicable 3 3.3 2.7 3.9
4 4.5 4.0 5.0
only to solder paste)—The powder mesh size and flux percent- 6A 6.0 5.1 7.0
age is identified by a single letter and a number in accordance A
Not applicable to flux types R, RMA, and RA.
with Table 4.
5. Ordering Information TABLE 4 Powder Mesh Size and Flux Percentage
5.1 Orders for material under this specification indicate the Size Symbol Powder Mesh Size
following information, as required, to adequately describe the A <325
desired material. B <200
C <100
5.1.1 Type designation (see 4.1),
Percentage Symbol Flux Percentage by Weight
5.1.2 Detailed requirements for special forms,
5.1.3 Dimensions of ribbon and wire solder (see 9.2), Min Max
1 1 5
5.1.4 Unit weight, 2 6 10
5.1.5 Packaging (see Section 18), 3 11 15
5.1.6 Marking (see Section 17), 4 16 20
5 21 25
5.1.7 ASTM specification number and issue, marked on (a) 6 26 30
purchase order and (b) package or spool, and 7 >30
5.1.8 Special requirements, as agreed upon between sup-
plier and purchaser.
7.2 Flux (applicable to flux-core ribbon, wire, and solder
6. Materials and Manufacture
paste):
6.1 The producer must have each lot of solder metal as 7.2.1 Type R—The flux is composed of Grade WW or WG
uniform in quality as practicable and of satisfactory appearance gum rosin of Test Methods D 509. The rosin shall have a
in accordance with best industrial practices. Each bar, ingot, or toluene–insoluble matter content of not more than 0.05
other form in which the solder is sold must be uniform in weight % in accordance with Test Method D 269, a minimum
composition with the entire lot. acid number of 160 mg KOH/1 g sample in accordance with
7. Chemical Composition Test Methods D 465, a minimum softening point of 70°C in
7.1 Solder Alloy—The solder alloy composition is as speci- accordance with Test Method E 28, and a minimum saponifi-
fied in Table 5. cation number of 166 in accordance with Test Methods D 464.
When solvents or plasticizers are added, they must be nonchlo-
NOTE 1—By mutual agreement between supplier and purchaser, analy- rinated.
sis may be required and limits established for elements or compounds not 7.2.2 Type RMA—The flux is composed of rosin conform-
specified in Table 5.
ing to 7.2.1. Incorporated additives provide a material meeting
TABLE 1 Form the requirements of 8.2 for type RMA. When solvents or
Symbol Form plasticizers are added, they must be nonchlorinated.
B Bar 7.2.3 Type RA—The flux is composed of rosin conforming
I Ingot to 7.2.1. Incorporated additives provide a material meeting the
P Powder
R Ribbon
requirements of 8.2 for Type RA. When solvents or plasticizers
S SpecialA are added, they must be nonchlorinated.
W Wire 7.2.4 Type OA—The flux is composed of one or more
A
Includes pellets, preforms, etc. water-soluble organic materials.
2
B 32
TABLE 5 Solder Compositions
Composition, %A,B Melting RangeC
Alloy Sn Pb Sb Ag Cu Cd Al Bi As Fe Zn Ni Se Solidus Liquidus UNS
Grade 1 2 3 4 5 6 7 8 9 10 11 12 13 Number
°F °C °F °C
Section 1: Solder Alloys Containing Less than 0.2 % Lead
Sn96 Rem 0.10 0.12 3.4–3.8 0.08 0.005 0.005 0.15 0.01 0.02 0.005 ... ... 430 221 430 221 L13965
max max
Sn95 Rem 0.10 0.12 4.4–4.8 0.08 0.005 0.005 0.15 0.01 0.02 0.005 ... ... 430 221 473 245 L13967D
Sn94 Rem 0.10 0.12 5.4–5.8 0.08 0.005 0.005 0.15 0.01 0.02 0.005 ... ... 430 221 536 280 L13969D
Sb5 94.0 min 0.20 4.5–5.5 0.015 0.08 0.005 0.005 0.15 0.01 0.04 0.005 ... ... 450 233 464 240 L13950
EE Rem 0.10 0.05 0.25–0.75 3.0–5.0 0.005 0.005 0.02 0.05 0.02 0.005 ... ... 440 225 660 349 L13935D
HAE Rem 0.10 0.5–4.0 0.1–3.0 0.1–2.0 0.005 0.005 0.15 0.05 0.02 0.5–4.0 ... ... 420 216 440 227 L13955D
HBE Rem 0.10 4.0–6.0 0.05–0.5 2.0–5.0 0.005 0.005 0.15 0.05 0.02 0.01 0.05–2.0 ... 460 238 660 349 L13952D
HNE Rem 0.10 0.05 0.05–0.15 3.5–4.5 0.005 0.005 0.15 0.05 0.02 0.005 440 225 660 350 L13933D
ACE Rem 0.10 0.05 0.2–0.3 0.1–0.3 0.005 0.005 2.75– 0.01 0.02 0.005 0.001 ... 403 206 453 234 L13964D
3.75
E
OA Rem 0.10 0.05 0.09–0.10 2.8–3.2 0.005 0.005 0.9–1.1 0.01 0.02 0.005 ... ... 420 216 460 238 L13937D
AM Rem 0.10 0.8–1.2 0.4–0.6 2.8–3.2 0.005 0.005 0.15 0.01 0.02 0.005 ... ... 430 220 446 230 L13938D
TC Rem 0.20 0.05 0.015 4.0–5.0 0.005 0.005 0.05 0.05 0.04 0.005 0.005 0.04– 419 215 660 350 L13931D
0.20
WS Rem 0.10 1.0–1.5 0.2–0.6 3.5–4.5 0.005 0.005 0.02 0.05 0.02 0.005 ... ... 440 225 660 350 L13939
Section 2: Solder Alloys Containing Lead
Sn70 69.5–71.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.03 0.02 0.005 ... 361 183 377 193 L13700
Sn63 62.5–63.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.03 0.02 0.005 ... 361 183 361 183 L13630
Sn62 61.5–62.5 Rem 0.50 1.75–2.25 0.08 0.001 0.005 0.25 0.03 0.02 0.005 ... 354 179 372 189 L13620D
Sn60 59.5–61.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.03 0.02 0.005 ... 361 183 374 190 L13600
Sn50 49.5–51.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.025 0.02 0.005 ... 361 183 421 216 L55031
Sn45 44.5–46.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.025 0.02 0.005 ... 361 183 441 227 L54951
Sn40A 39.5–41.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 361 183 460 238 L54916
Sn40B 39.5–41.5 Rem 1.8–2.4 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 365 185 448 231 L54918
Sn35A 34.5–36.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 361 183 447 247 L54851
Sn35B 34.5–36.5 Rem 1.6–2.0 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 365 185 470 243 L54852
Sn30A 29.5–31.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 361 183 491 255 L54821
Sn30B 29.5–31.5 Rem 1.4–1.8 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 365 185 482 250 L54822
Sn25A 24.5–26.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 361 183 511 266 L54721
Sn25B 24.5–26.5 Rem 1.1–1.5 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 365 185 504 263 L54722
Sn20A 19.5–21.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 361 183 531 277 L54711
Sn20B 19.5–21.5 Rem 0.8–1.2 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 363 184 517 270 L54712
Sn15 14.5–16.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 437 225 554 290 L54560
Sn10A 9.0–11.0 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 514 268 576 302 L54520
Sn10B 9.0–11.0 Rem 0.20 1.7–2.4 0.08 0.001 0.005 0.03 0.02 0.02 0.005 ... 514 268 570 299 L54525
Sn5 4.5–5.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 586 308 594 312 L54322
Sn2 1.5–2.5 Rem 0.50 0.015 0.08 0.001 0.005 0.25 0.02 0.02 0.005 ... 601 316 611 322 L54210
Ag1.5 0.75–1.25 Rem 0.40 1.3–1.7 0.30 0.001 0.005 0.25 0.02 0.02 0.005 ... 588 309 588 309 L50132
Ag2.5 0.25 Rem 0.40 2.3–2.7 0.30 0.001 0.005 0.25 0.02 0.02 0.005 ... 580 304 580 304 L50151
Ag5.5 0.25 Rem 0.40 5.0–6.0 0.30 0.001 0.005 0.25 0.02 0.02 0.005 ... 580 304 716 380 L50180
A
Limits are % max unless shown as a range or stated otherwise.
B
For purposes of determining conformance to these limits, an observed value or calculated value obtained from analysis shall be rounded to the nearest unit in the last
right-hand place of figures used in expressing the specified limit, in accordance with the rounding method of Practice E 29.
C
Temperatures given are approximations and for information only.
D
LXXXXX is a proposed number.
E
Grades E and OA are covered by U.S. patents held by Engelhard Corp, Mansfield, MA, and Oatey Co. Cleveland, OH respectively. Federated Fry Metals, Altoona, PA
and Taracorp Inc, Atlanta, GA have applied for patents on grades AC and TC respectively. Grades HA, HB, and HN are covered by patents assigned to J. W. Harris Co.,
Cincinnati, OH. Interested parties are invited to submit information regarding identification of acceptable alternatives to these patented items to the Committee on
Standards, ASTM Headquarters, 100 Barr Harbor Drive, West Conshohocken, PA 19428. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend.

7.2.5 Type OS—The flux is composed of one or more method used to determine the viscosity must be agreed upon
water-insoluble organic materials, other than Types R, RMA, between the supplier and purchaser.
and RA, which are soluble in organic solvents. 8.2 The following variables must be taken into account
7.2.6 Type IS—The flux is composed of one or more when relating one viscosity measurement to another: type of
inorganic salts or acids with or without an organic binder and viscometer used, spindle size and shape, speed (r/min), tem-
solvents. perature of sample, and the use or non-use of a helipath.
8. Physical Properties and Performance Requirements 8.3 Requirements for Flux—The flux must meet the physi-
8.1 Solder Paste—Solder paste must exhibit smoothness of cal and performance requirements specified in Table 6 as
texture (no lumps) and the absence of caking and drying. applicable.
8.1.1 Powder Mesh Size—The solder powder mesh size 8.3.1 Solder Pool—When solder is tested as specified in
shall be as specified (see 5.1.1 and 4.1.5) when the extracted 13.3.2, there must be no spattering, as indicated by the
solder powder is tested as specified in 13.4. presence of flux particles outside the main pool of residue. The
8.1.2 Viscosity—The viscosity of solder paste and the flux must promote spreading of the molten solder over the
3
B 32
TABLE 6 Requirements for Flux
Test Type R Type RMA Type RA Other Flux Types Method Section
Weight of flux see Table 3 see Table 3 see Table 3 see Table 3 13.3.1
Solder poolA see 8.2.1 see 8.2.1 see 8.2.1 see 8.2.1 13.3.2
Spread factorB 80 min 80 min 80 min not required 13.3.3
DrynessC see 8.2.2 see 8.2.2 see 8.2.2 not required 13.3.4
Resistivity of water extract 100 000 min 100 000 50 000 not required 13.3.5
(V·cm)
Chlorides and bromidesD see 8.2.3 see 8.2.3 not required not required 13.3.6
Copper mirrorE pass pass not required not required 13.3.7
A
Applicable only to composition 60/40.
B
Applicable only to composition 60/40 in the form of flux-core wire or solderpaste.
C
Applicable only to composition 60/40 in the form of flux-core wire.
D
Applicable only to flux-core wire and solderpaste.
E
Applicable only to flux-core wire.

coupon to form integrally thereon a coat of solder that shall 11.2 Frequency of Sampling—Frequency of sampling for
feather out to a thin edge. The complete edge of the solder pool determination of chemical composition shall be in accordance
must be clearly visible through the flux residue. with Table 7. For spools and coils, the sample is obtained by
8.3.2 Dryness—When solder is tested as specified in 13.3.2, cutting back 6 ft (1.8 m) of wire from the free end and then
the surface of the residue must be free of tackiness, permitting taking the next 6 ft for test. In other forms, an equivalent
easy and complete removal of applied powdered chalk. sample is selected at random from the container.
8.3.3 Chlorides and Bromides Test—When the extracted 11.3 Other Aspects of Sampling—Other aspects of sampling
flux is tested as specified in 13.3.6, the test paper will show no conforms in the case of bar and ingots, to Practice E 88. For
chlorides or bromides by a color change of the paper to fabricated solders the appropriate reference is Practice E 55.
off-white or yellow white.
8.3.4 Copper Mirror Test—When tested as specified in 12. Specimen Preparation
13.3.7, the extracted flux will have failed the test if, when 12.1 Flux-Cored Ribbon and Wire Solder and Solder
examined against a white background, complete removal of the Paste—Each sample of flux-cored ribbon or wire solder or
copper film is noted, as evidenced by the white background solder paste is melted in a clean container under oil and mixed
showing through, and must be rejected. Discoloration of the thoroughly. After the flux has risen to the top, the alloy is
copper due to a superficial reaction or to only a partial poured carefully into a cool mold (care should be taken to
reduction of the thickness of the copper film is not cause for allow the flux and alloy to separate completely), forming a bar
rejection. approximately 1⁄4in. (6.4 mm) thick. The bar is cleaned of flux
residue and sampled for analysis as specified in 12.3.
9. Dimensions and Unit Weight 12.1.1 Flux Extraction Procedure:
9.1 Bar and Ingot Solder—The dimensions and unit weight 12.1.1.1 Flux-Cored Solder—The flux core is extracted as
of bar and ingot solder will be as agreed upon between supplier follows: Cut a length of the flux-cored solder weighing
and purchaser. approximately 150 g and seal the ends. Wipe the surface clean
9.2 Wire solder (solid and flux-cored)—The dimensions and with a cloth moistened with acetone. Place the sample in a
unit weight of wire solder are specified in 5.1.3 and 5.1.4. The beaker, add sufficient distilled water to cover the sample, and
tolerance on the specified outside diameter shall be 65 % or boil for 5 to 6 min. Rinse the sample with acetone and allow to
60.002 in. (0.05 mm), whichever is greater. dry. Protecting the solder surface from contamination, cut the
9.3 Other Forms: sample into 3⁄8-in. (9.5 mm) (maximum) lengths without
9.3.1 Dimensions for ribbon and special forms will be crimping the cut ends. Place the cut lengths in an extraction
agreed upon between supplier and purchaser. tube of a chemically clean soxhlet extraction apparatus and
9.3.2 The unit weight of solder paste is specified in 5.1.4. extract the flux with reagent grade, 99 % isopropyl alcohol
until the return condensate is clear. The resistivity of water
10. Workmanship, Finish, and Appearance extract, copper mirror, and chlorides and bromides tests are
10.1 All forms of solder must be processed in such a manner performed using a test solution prepared by concentrating the
as to be uniform in quality and free of defects that will affect solids content in the flux extract solution to approximately
life, serviceability, or appearance. 35 % by weight by evaporation of the excess solvent. The exact
11. Sampling solids content of the test solution are determined on an aliquot,
dried to constant weight in a circulating air oven maintained at
11.1 Care must be taken to ensure that the sample selected 85 6 3°C.
for testing is representative of the material. The method of
sampling consists of one of the following methods: TABLE 7 Frequency of Sampling
11.1.1 Samples taken from the final solidified cast or fabri- Number of Samples (spools,
Size of Lot, lb (kg)
cated product. coils, containers or pieces)
11.1.2 Representative samples obtained from the lot of Up to 1000 (450), incl 3
molten metal during casting. The molten sample is poured into Over 1000 to 10 000 (450 to 4500), incl 5
Over 10 000 (4500) 10
a cool mold, forming a bar approximately 1⁄4in. (6.4 mm) thick.
4
B 32
12.1.1.2 Solder Paste—The flux is extracted as follows: solder a few times to free any entrapped flux. Allow the solder
Place 200 mL of reagent grade, 99 % isopropyl alcohol in a to cool until it solidifies; clean thoroughly of flux residues and
chemically clean Erlenmeyer flask. Add 40 6 2 g of solder reweigh the solder.
paste to the flask, cover with a watch glass, and boil for 10 to 13.3.1.2 Calculation—Calculate the weight percent of flux
15 min using medium heat. Allow the powder to settle for 2 to as follows:
3 min and decant the hot solution into a funnel containing filter C2S
paper, collecting the flux extract in a chemically clean vessel. F 5 C 3 100 (1)

NOTE 2—The solution in isopropyl alcohol does not necessarily have to


be clear. The resistivity of water extract and chlorides and bromides tests
where:
shall be performed using a test solution prepared by concentrating the F 5 weight percent of flux,
solids content in the flux extract solution to approximately 35 % by weight C 5 initial weight of solder sample, g, and
by evaporation of the excess solvent. The exact solids content of the test S 5 final weight of solder sample, g.
solution shall be determined on an aliquot, dried to constant weight in a 13.3.2 Solder Pool (applicable only to composition 60/
circulating air oven maintained at 85 6 3°C. 40)—For each sample being tested, three coupons 1.5 in. (38
12.2 Solid Ribbon and Wire Solder—Each sample of solid mm) square shall be cut from 0.063 in. (1.6 mm) thick sheet
ribbon and wire solder is prepared in accordance with 12.1, as copper. For flux Type IA only, the coupons shall be cut from
applicable. cold-rolled commercial sheet steel, approximately 0.063 in.
12.3 Bar and Ingot Solder—Each sample piece is cut in half thick. The coupons are degreased by immersion in
and one half marked and held in reserve. The remaining half is trichloroethylene or other suitable short-chain solvent. Both
melted in a clean container, mixed thoroughly and poured into surfaces of each coupon are cleaned to a bright finish, using a
a cool mold, forming a bar approximately 1⁄4 in. (6.4 mm) 10 % fluoroboric acid dip. The coupons are washed with tap
thick. Sampling is performed by one of the following methods: water and dried thoroughly with a clean cloth. Approximately
12.3.1 Sawing—Saw cuts are made across the bar at equal 0.2 g of flux-core ribbon or wire or approximately 2 g of solder
intervals of not more than 1 in. (2.5 cm) throughout its length. paste is placed in the center of each coupon. (The area of the
If it is impractical to melt the bar or ingot as specified above, solder paste must not exceed that of a 0.375 in. (9.5 mm)
saw cuts are made across each piece at equal intervals of not diameter circle.) The solder is melted in an oven maintained at
more than 1 in. (2.5 cm) throughout its length. No lubricants 315 6 15°C. The solder pool is visually examined for
are used during sawing. The specimen consists of not less than thickness of edge. When the test is completed, each coupon is
5 oz (143 g) of mixed sawings. inspected for evidence of spattering of flux.
12.3.2 Drilling—The bar is drilled at least halfway through 13.3.3 Spread Factor (applicable only to composition Sn60,
from two opposite sides. A drill of about 1⁄2 in. (12.7 mm) in flux Types R, RMA, and RA in the form of flux-core wire or
diameter is preferred. In drilling, the holes are placed along a solder paste):
diagonal line from one corner of the pig to the other. The 13.3.3.1 Preparation of Coupon—Five coupons 2 in. (12.9
drillings are clipped into pieces not over 1⁄2 in. (12.7 mm) in cm2) square are cut from 0.005 in. (0.13 mm) thick electrolytic
length and mixed thoroughly. The specimen consists of not less copper sheets. The coupons are cleaned in a 10 % fluoroboric
than 5 oz (143 g). acid dip. One corner of each coupon is bent upwards to permit
handling with tweezers. The coupons are not handled with bare
13. Test Methods hands. The coupons are vapor-degreased and then oxidized for
13.1 Visual and Dimensional Examination: 1 h in an electric oven at 150 6 5°C for testing of flux Types
13.1.1 Ribbon and Wire Solder (Solid and Flux-Cored)— R and RMA and 205 6 5°C for testing of flux Types RA. All
Ribbon and wire solder must be examined to verify that the coupons must be at the same level in the oven. All coupons are
dimensions, unit weight, and workmanship are in accordance removed from the oven and placed in tightly closed glass
with the applicable requirements. bottles until ready for use.
13.1.2 Solder Paste—Solder paste must be examined for 13.3.3.2 Procedure:
smoothness of texture (no lumps), caking, drying, unit weight, (a) Flux-Cored Wire—Ten or more turns of 0.063-in. (1.6-
and workmanship in accordance with the applicable require- mm) diameter flux-cored solder are tightly wrapped around a
ments. mandrel. The solder is cut through with a sharp blade along the
13.1.3 Bar and Ingot Solder—Bar and ingot solder must be longitudinal axis of the mandrel. The rings are slid off the
examined to verify that the unit weight, marking, and work- mandrel and the helix removed by flattening each ring. The
manship are in accordance with the applicable requirements. diameter of the mandrel must be of such a size so as to produce
13.2 Alloy Composition—In case of dispute, the chemical a ring weighing 0.500 6 0.025 g. Ten rings are prepared. A
analysis is made in accordance with Test Methods E 46, solder ring is placed in the center of each one of the five
Method E 51, and Methods E 87. coupons. The coupons are placed horizontally on a flat
13.3 Flux: oxidized copper sheet in a circulating–air oven at 205 6 5°C
13.3.1 Determination of Weight Percent of Flux: for 6 min + 10 s, with all coupons being at the same level. At
13.3.1.1 Select a minimum of 20 g of flux-core ribbon or the end of − 0, 6 min, the coupons are removed from the oven
wire or solder paste. Weigh the sample in a clean porcelain and allowed to cool. Excess flux residue is removed by
crucible determining the weight to the nearest 0.01 g. Heat washing with alcohol. The height, H, of the solder spot is
until the solder is completely molten. Carefully stir the molten measured to the nearest 0.001 cm, and the results averaged.
5
B 32
Five additional solder-ring specimens are melted together in a the resistivity of the water in any beaker is less than 500 000
small, porcelain combustion boat on a hot plate. The molten V·cm, the complete process above must be repeated. Two of
solder is stirred several times to free any entrapped flux. After these beakers are retained as controls. Add 0.1006 0.005 cm3
cooling, the solder slab is removed from the boat, the excess of the flux test solution to each of the other three beakers by
flux removed by washing with alcohol, and the loss of weight means of a calibrated dropper or microlitre syringe. The
in water determined to the nearest 0.001 g. heating of all five beakers is started simultaneously. As the
(b) Solder Paste—The coupons are removed from the bottles contents of each beaker comes to a boil, the boiling time is for
and weighed to the nearest 0.001 g. A metal washer with an 1 min followed by quick cooling of the beakers, to the touch,
internal diameter of 0.250-in. (6.4-mm) is placed in the center under running tap water or by immersing in ice water. The
of each coupon and each opening is filled with solder paste. cooled, covered beakers are placed in a water bath maintained
The excess solder paste is wiped off the washer using a spatula at 23 6 2°C. When the thermal equilibrium is reached, the
and then the washer is removed carefully. The coupons with resistivity in each of the five beakers is determined at this
solder paste are reweighed to the nearest 0.001 g. temperature as follows:
NOTE 3—The thickness of the washer is such that the solder weighs 13.3.5.1 Thoroughly wash the conductivity cell with
from 0.45 to 0.55 g. The coupons are placed horizontally on a flat oxidized distilled water and immerse it in the water extract of one
copper sheet in a circulating–air oven at 205 6 5°C for 6 min + 10 s, with sample. Make instrument reading.
all coupons being at the same level. At the end of 6 min, the coupons are 13.3.5.2 Thoroughly wash conductivity cell in distilled
removed from the oven and allowed to cool. Excess flux residue is water and immerse in a water control. Make instrument
removed by washing with alcohol. The height, H, of the solder spot is
reading.
measured to the nearest 0.001 cm, and the results averaged. An amount of
solder paste equal to the total weight of solder paste on the five coupons 13.3.5.3 Thoroughly wash conductivity cell in distilled
is melted in a small, porcelain combustion boat on a hot plate. The molten water and immerse in a water extract. Make instrument
solder is stirred several times to free any entrapped flux. After cooling, the reading.
solder slab is removed from the boat, the excess flux removed by washing 13.3.5.4 Thoroughly wash conductivity cell in distilled
with alcohol, and the loss of weight in water determined to the nearest water and continue measuring resistivities of the remaining
0.001 g.
control and water extract.
13.3.3.3 Calculation—The loss in weight of the solder slab 13.3.5.5 The resistivity of each of the controls must not be
in water is divided by five. This is the volume, V, of the solder less than 500 000 V·cm. If the control value is less than
to the nearest 0.001 cm3. The diameter, D, of the equivalent 500 000 V·cm, it indicates that the water was contaminated
sphere is 1.2407 3=V . The spread factor is calculated in with water–soluble ionized materials and the entire test must be
accordance with the following formula: repeated. The mean of the specific resistivities of the water
Spread factor ~%! 5 ~D 2 H!/D 3 100 (2) extracts of the flux must be calculated.
13.3.4 Dryness (applicable only to composition Sn60, flux 13.3.6 Chlorides and Bromides Test (applicable only to flux
Types R, RMA, and RA in the form of flux-core wire)—The Types R and RMA)—One drop of the flux test solution
dryness test is performed on samples prepared in accordance (approximately 0.05 mL/drop) is placed on a small dry piece of
with 13.3.3.1 and 13.3.3.2(a) except that after heating the silver chromate test paper. The drop shall remain on the test
coupons in the oven, the flux residue is not removed. The paper for 15 s prior to immersing the test paper in reagent grade
coupons are allowed to cool for 1⁄2 h. Powdered chalk is dusted 99 % isopropyl alcohol for 15 s to remove residual organic
onto the surface of the residual flux and the ability to remove materials. The test paper is dried for 10 min. The test paper is
the chalk from the surface of the flux by light brushing is visually examined for color change.
observed. 13.3.7 Copper Mirror Test (applicable only to flux Types R
13.3.5 Resistivity of Water Extract (applicable only to flux and RMA in the form of flux-core wire):
Types R, RMA, and RA)—The resistivity of water extract is 13.3.7.1 Preparation of the Control-Standard Flux—A
determined using the flux test solution. Five watch glasses and control-standard flux is prepared by using 35 % weight of
five acid/alkali resistant, tall form graduated beakers are Grade WW gum rosin conforming to Test Methods D 509
thoroughly cleaned by washing in hot water detergent solution, dissolved in reagent grade 99 % isopropyl alcohol.
rinsing several times with tap water followed by at least five 13.3.7.2 Preparation of Copper Mirror—A copper mirror
rinses with distilled water. CAUTION—All beakers must be consists of a vacuum–deposited film of pure copper metal on
covered with the watch glasses to protect the contents from one surface of a flat sheet of clear, polished glass. The
contaminants. The beakers’ dimensions are such that when the thickness of the copper film must be uniform and must permit
conductivity cell is immersed in 50 mL of liquid contained 10 6 5 % transmission of normal incident light of 5000 Å units
therein, the electrodes are fully covered. Each cleaned beaker as determined with any suitable standard photoelectric
is filled to the 50 mL mark with distilled water. The beakers are spectrophotometer. To prevent oxidation of the copper mirror,
immersed in a water bath maintained at 23 6 2°C. When it is recommended that the mirrors be stored in closed
thermal equilibrium is reached, the resistivity of the distilled containers which have been flushed with nitrogen. Immediately
water in each beaker is measured at this temperature with a prior to testing, the copper mirror is immersed in a 5 % solution
conductivity bridge using a conductivity cell with a cell of ethylene diamine tetra acetic acid or similar chelating agent
constant of approximately 0.1. The resistivity of the distilled for copper oxide, rinsed thoroughly in running water,
water in each beaker must not be less than 500 000 V·cm. If immersed in clean ethyl or methyl alcohol, and dried with
6
B 32
clean, oil-free air. The copper film is examined in good light. to the producer or supplier promptly and in writing. In case of
The copper mirror is acceptable if no oxide film is visible and dissatisfaction with the results of the test, the producer or
the copper film shows no visible damage. supplier may make claim for a rehearing.
13.3.7.3 Procedure—Approximately 0.05 mL of the flux
test solution and 0.05 mL of the control–standard flux is placed 16. Certification
adjacent to each other on the face of a flat, vacuum–deposited
copper mirror. The dropper must not be permitted to touch the 16.1 When specified in the purchase order or contract a
copper surface, and the mirror is protected at all times from producer’s or supplier’s certification must be furnished to the
dirt, dust, and fingerprints. The mirror is placed in a horizontal purchaser that the material was manufactured, sampled, tested,
position at 23 6 2°C and 506 5 % relative humidity in a and inspected in accordance with this specification and has
dust–free cabinet for 246 1⁄2 h. At the end of the 24-h storage been found to meet the requirements. When specified in the
period, the test flux and the control standard flux are removed purchase order or contract, a report of the test results must be
by immersing the copper mirror in clean isopropyl alcohol. The furnished.
clean mirror is examined visually for compliance of the test
flux and the control–standard flux with 8.2. If the 17. Product Marking
control–standard flux does not comply with 8.2, the test must 17.1 The producer’s name or trademark must be stamped or
be repeated using a new copper mirror. cast on each bar or ingot. The alloy grade designation or
13.4 Powder Mesh Size (applicable only to solder paste)—
nominal composition, or both, must be stamped on each bar or
Place 200 mL of reagent grade, 99 % isopropranol in a
ingot for identification along with the specification number.
chemically clean beaker. Add 40 6 2 g of solder paste to the
beaker, cover with a watch glass and boil for 10 to 15 min 17.2 Each spool or container must be marked to show the
using medium heat. Allow the powder to settle for 2 to 3 min specification number, type designation, dimensions, and unit
and decant the hot solution. Wash the powder with weight of wire or other form and lot number. The producer’s
isopropranol until all of the flux is removed. Replace name or trademark must be marked on the spool or container.
isopropanol with deionized or distilled water for solder pastes
containing a water–soluble flux base. Completely dry the 18. Packaging and Package Marking
solder powder at 110°C (230°F) so that all particles are 18.1 The material must be packaged to provide adequate
separated. A minimum of 80 % of the powder must pass protection during normal handling and transportation. The type
through the appropriate size sieve (see 4.1.5) in order to be of packaging and gross weight of containers will, unless
classified for that mesh size. otherwise agreed upon, be at the producer’s or supplier’s
14. Inspection discretion, provided that they are such as to ensure acceptance
by common or other carriers for safe transportation to the
14.1 Unless otherwise specified in the contract or purchase
order, the supplier is responsible for the performance of all delivery point.
inspection requirements as specified herein. Except as 18.1.1 For bar and ingot solder a lot number must be marked
otherwise specified in the contract or order, the supplier may on each shipping container or inside package.
use his own or any other facilities suitable for the performance 18.1.2 When special preservation, packaging and packing
of the inspection requirements specified unless disapproved by requirements are agreed upon between purchaser and supplier,
the purchaser. The purchaser reserves the right to perform any marking for shipment of such material must be in accordance
of the inspections set forth in the specification where such with Fed. Std. No. 123 for civil agencies and MIL–STD–129
inspections are deemed necessary to ensure supplies and for military agencies.
services conform to prescribed requirements. 18.2 Each shipping container must be marked with the
14.1.1 Test Equipment and Inspection Facilities—Test and purchase order number, unit weight, and producer’s name or
measuring equipment and inspection facilities of sufficient trademark.
accuracy, quality, and quantity to permit performance of the
required inspection must be established and maintained by the 19. Keywords
supplier.
19.1 bar; flux; flux cored solder; ingot; lead–silver alloys;
15. Rejection and Rehearing lead–tin alloys; lead–tin–silver alloys; powder; ribbon; solder
15.1 Material that fails to conform to the requirements of alloy; solder metal; solder uses; tin–antimony alloys;
this specification may be rejected. Rejection must be reported tin–copper alloys; tin–silver alloys; wire

7
B 32

ANNEX

(Mandatory Information)

A1. INTENDED USE

A1.1 Alloy Compositions: such as protective coatings on steel sheet where a high tin
A1.1.1 Sn96—This is a special–purpose solder with a content alloy is not required.
higher joint strength than tin–lead solders. It is intended for use A1.1.18 Sn15—This alloy is used for coating and joining
in the food processing industry because of its nontoxic metals.
characteristic. It also provides a fairly good color match to A1.1.19 Sn10A—This alloy is used for coating and joining
stainless steel. metals, and where soldered connections will be exposed to
A1.1.2 Sn95, Sn94, E, AC, AM, and WS—These alloys are high operating temperatures exceeding 400°F (204°C).
intended for use in soldering medical components and jewelry A1.1.20 Sn10B—Similar to Sn10A, this alloy minimizes the
applications, for joining copper pipe and tube intended for leaching of silver from silver alloy coated surfaces. It is used in
potable water systems, and for applications in the food hybrid microelectronic and automotive electronic applications
industry. These alloys display excellent wetting and exhibit where a high service temperature is encountered.
relatively high heat resistance. A1.1.21 Sn5—This alloy is used for coating and joining
A1.1.3 Sn70—This is a special–purpose solder where a high metals, and where soldered connections will be exposed to
tin content is necessary. It is often used for soldering zinc and high operating temperatures exceeding 475°F (246°C). Its
for coating metals. wetting ability is not as good as Sn10A.
A1.1.4 Sn63—This tin–lead eutectic solder is commonly A1.1.22 Sn2—This alloy has been used to solder
used for soldering printed circuit boards where temperature automobile radiator cores.
limitations are critical and in applications where an extremely A1.1.23 Sb5—This alloy is used for electrical and
short melting range is required. electronic connections subjected to peak temperatures of
A1.1.5 Sn62—This is a special–purpose solder widely used approximately 465°F. It is also used for sweating of copper
for soldering silver coated surfaces. tubing in solar heating, plumbing and refrigeration equipment.
A1.1.6 Sn60—Similar to Sn63, this solder is preferred for A1.1.24 Ag1.5—This alloy is used interchangeably with
soldering electrical and electronic connections and for coating alloy Ag2.5, but has a better shelf life and does not develop a
metals. black surface deposit when stored under humid environmental
A1.1.7 Sn50—This general purpose alloy can be used for conditions.
non-critical electrical soldering and applications such as A1.1.25 Ag2.5—The alloy is for use on copper, brass and
joining sheet metal, pipe, tubing and other structural shapes. similar metals with torch heating. It requires the use of a flux
A1.1.8 Sn45—This is a general purpose alloy similar to having a zinc chloride base to produce a good joint on untinned
Sn50. surfaces. A rosin flux is unsatisfactory on untinned surfaces.
A1.1.9 Sn40A—This alloy can be used for the same This alloy is susceptible to corrosion under humid
purposes as alloy Sn50, but it is not as workable in bit environmental conditions.
soldering or sweating. It is frequently used for dip soldering A1.1.26 Ag5.5—This alloy will develop a shearing strength
and as a wiping solder for joining lead pipes and cable sheaths. of 1500 psi at 350°F (177°C). When soldering hard–drawn
A1.1.10 Sn40B—This alloy is similar to Sn40A, but it is not brass or copper, the application temperature should not exceed
recommended for use on galvanized iron. 850°F (454°C). A typical application is on thermocouples for
A1.1.11 Sn35A—This is a plumber’s solder similar to alloy aircraft engines where relatively high operating temperatures
Sn35B but with a lower antimony content. will not affect strength of the solder. Precautions noted for
Ag2.5 also apply.
A1.1.12 Sn35B—This is the customary wiping or plumber’s
A1.1.27 HA and OA—A lead-free solder for joining copper
solder. Higher antimony content in wiping solders promotes
plumbing systems. It has a lower melting temperature than
fine grain size and greater strength.
Grade Sb5 and is suitable for filling connections with wider
A1.1.13 Sn30A—This alloy is used as an automobile–body
clearances.
solder and for removing heat–strippable insulation during high
A1.1.28 HN, HB and TC—A lead-free solder for joining
temperature (700 to 900°F) tinning of wires.
copper plumbing systems. This solder has a wide liquidus/
A1.1.14 Sn30B—This alloy is used as an automobile–body
solidus range making it useful for filling solder connections
solder for filling dents and seams.
that have wide clearances. It can also be used where service
A1.1.15 Sn25A and Sn25B—These alloys are for uses
conditions require a solder with a higher melting temperature.
similar to that for alloy Grades Sn20 and Sn30.
A1.1.16 Sn20A—This is an automobile–body solder with a A1.2 Soldering of Zinc and Cadmium—In as much as zinc
lower antimony content than alloy Sn20B. and cadmium appear to form intermetallic alloys with the
A1.1.17 Sn20B—This is widely used automobile–body antimony in the solder, compositions Sn40B, Sn35B, Sn30B,
solder for filling dents and seams, and for general purposes Sn25B, Sn20B and Sb5 should not be used for soldering zinc
8
B 32
or cadmium, or zinc–coated or cadmium-coated iron or steel. soldering may be corrosive and contaminate the area
These intermetallic alloys have high melting points which surrounding the joint, this too must be susceptible to effective
inhibit the flow of the solder, resulting in brittle joints. cleaning by the combination of materials and procedures to be
used. There are many standard electrical soldering applications
A1.3 Flux Type :
that use this type of flux.
A1.3.1 Type R—Type R is intended for use in the A1.3.4 Type OA—Type OA is used for general soldering
preparation of soldered joints for high reliability electrical and purposes on copper, nickel, brass, etc. Some fluxes of this type
electronic applications.
can be used for electrical and electronic soldering applications
A1.3.2 Type RMA—Type RMA provides a slightly more
but complete removal of flux is necessary after soldering to
active fluxing action than Type R and is intended for similar
prevent corrosion and current leakage.
uses.
A1.3.3 Type RA—Type RA provides more active fluxing A1.3.5 Type OS—Type OS has uses similar to Type OA.
action than Type RMA. It should be used for soldering joints A1.3.6 Type IS—Type IS is intended for use, exclusive of
which are readily accessible so that the residues can be that in electrical or electronic circuits, in the preparation of
removed by cleaning agents and procedures commonly used in mechanical and structural joints for all solderable metals, other
industry. Since the fumes and particulates given off during than aluminum, magnesium and their alloys.

The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection
with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such
patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your
views known to the ASTM Committee on Standards, 100 Barr Harbor Drive, West Conshohocken, PA 19428.