[~]$ moshell 169.254.2.

#####################################################################
# Welcome to MoShell 17.0b (LPA108514/1_R17B) #
# Finn Magnusson, Jan Pettersson #
# http://utran01.au.ao.ericsson.se/moshell #
# Contact: Finn.Magnusson@ericsson.com #
# Joakim.xo.Ostlund@ericsson.com #
#####################################################################

WARNING: the moshell version currently running is more than 190 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://utran01.au.ao.ericsson.se/moshell

Checking ip contact...OK

HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q

169.254.2.2> lt all

200808-22:50:41 169.254.2.2 17.0b stopfile=/tmp/3167


Please enter Username: rbs
Please enter rbs's Node Password:

$ssh_pid = 3231

Connected to 169.254.2.2 (RadioNode,ManagedElement=BASEBAND_5216)

Checking MOM version...MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


Parsing MOM (cached):
/home/Cliente/moshell_logfiles/logs_moshell/tempfiles/20200808-
224947_3144/MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8.xml.cache.gz .................
...................................................................................
..Done.
Using paramfile /home/Cliente/moshell/commonjars/pm/PARAM_MSRBS_16B.txt
Parsing file
/home/Cliente/moshell/commonjars/pm/PARAM_MSRBS_16B.txt ...........................
......Done.
Using imomdfile /home/Cliente/moshell/commonjars/pm/IMOMD_MSRBS_16B.txt
Using imomfile /home/Cliente/moshell/commonjars/pm/IMOM_MSRBS_16B.txt
Connected to 169.254.2.2 (RadioNode,ManagedElement=BASEBAND_5216)

Last MO: 6527. Loaded 6527 MOs. Total: 6528 MOs.

BASEBAND_5216> cvls

200808-22:51:33 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167
.
===================================================================================
========
200808-22:51 BackupName SwVersion
===================================================================================
========
LastCreatedBackup:
LastRestoredBackup:
-----------------------------------------------------------------------------------
--------
Current SwVersion: CXP9024418/6_R28U20 (17B)
BrmHouseKeeping: ENABLED (max: 20 backups)
BrmFailSafe: IDLE
RestoreEscalationList: s[1] = Auto integration backup - SITE_CONFIG_COMPLETE
===================================================================================
=====================================
SwVersion ProductData ProdDate Rel LMs InstallationDate
ActivationDate DeactivationDate
===================================================================================
=====================================
CXP9024418/6-R28U20 CXP9024418/6_R28U20 20190619 17B 76 2020-08-09 03:47:48
2020-08-09 03:48:29
===================================================================================
=====================================
UpgradePackage ProductData ProdDate Rel CreationDate State
===================================================================================
=====================================
CXP9024418/6-R28U20 CXP9024418/6_R28U20 20190619 17B 2020-08-09 03:47:46
COMMIT_COMPLETED
===================================================================================
=====================================
Id BackupName CreationTime SwVersion
Rel Type Stat MO
===================================================================================
=====================================
1 Auto integration backup - SITE_CONFIG_COMPLETE 2020-08-09 03:49:13
CXP9024418/6_R28U20 17B SYSCR OK BrmBackup=2
===================================================================================
=====================================
>>> Total: 1 CV's, 1 UP's

BASEBAND_5216> cvput /home/Cliente/4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-2020-08-08T11?


02?29+00?00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip

200808-22:52:13 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

Starting sshd on port 10914... OK

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
90 BrM=1,BrmBackupManager=1 importBackup
2
!!!! ERROR: Invalid value
'"sftp://Cliente@169.254.2.1:10914/home/Cliente/4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-
2020-08-08T11' for parameter 'uri'

===================================================================================
==============================
Total: 1 MOs attempted, 0 MOs actioned
Stopping sshd pid 3264...OK

Last MO: 6526. Loaded 6526 MOs. Total: 6527 MOs.

BASEBAND_

BASEBAND_5216> cvput home/cliente/4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-2020-08-08T11?


02?29+00?00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip

200808-23:00:50 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167
Error: zip file not found or invalid !

***********************************************************************************
****
cvls/cvmk/cvms/cvset/cvrm[u]/cvrbrm/cvcu/cvget[f][u]/cvput/cvls1/cvre/cvfa/cvfd
***********************************************************************************
****
CV backup handling: list, make local, make remote, remove, setstartable.

Command syntax (CPP):


* cvcu
* cvls [<cv-filter>]
* cvls1
* cvmk <cvname> [<operator>] [<comment>]
* cvset <cvname>|<cv-Id>
* cvms <cvname> [<operator>] [<comment>]
* cvrm <cvname>|<cv-filter>|<cv-Id>
* cvrmu <UP>
* cvrbrm <cvname>|<cv-filter>|<cv-Id>
* cvget[f] <cvname>|<cv-filter>|<cv-Id> [<destdir>]
* cvgetu <UP>
* cvput <zipped-cvfile>
* cvfa
* cvfd

Command Description (CPP):


A set of commands similar to the "cv" commands in OSE but operate through MO
interface instead of telnet/ssh (ie: no password).
* cvcu: display the current cv information only (equivalent of "cv cu").
* cvls: display both the current cv information (equivalent of "cv cu") and cv
list (equivalent of "cv ls"). It is possible to filter the output of cvls to only
show CVs where the CV name or CV attributes match a certain string. The proxy Id of
the CVs can be used in the commands cvrm and cvget. The display of CV proxy Id can
be disabled with command "safe+".
* cvls1: similar to the cvls command except that it executes via the OSE shell
instead of the MO service.
* cvmk: create a local cv backup. Operator name and comments (not longer than
40 characters) can be given as argument.
* cvset: set a cv as startable.
* cvms: create a cv and make it startable (combination of cvmk and cvset)
* cvrm: remove one or more cv's. If the argument does not match an existing CV
then all CVs matching that string will be removed. A confirmation message is
printed before removal. The CV(s) will automatically be removed from rollback list
when necessary.
* cvrmu: remove all CV's connected to a specific UP (same as cvrm but with the
UP as argument).
* cvrbrm: remove one or more cv's from the rollback list. If the argument does
not match an existing CV then all CVs matching that string will be removed. A
confirmation message is printed before removal.
* cvget[f]: make a remote backup of a cv to the workstation. The operation is
done with the MO action putToFtpServer unless option "f" has been specified, in
which case the transfer will be done by FTP/SFTP. The second argument is optional.
If not given, a default folder is chosen for the backup
~/moshell_logfiles/logs_moshell/cv/<node>/<date>_<time>/
* cvgetu : make a remote backup of all CVs connected to a specific UP (same as
cvget but with the UP as argument).
* cvput: transfer a remote CV backup (zip file) from the workstation to the
node. The operation is done with the MO action getFromFtpServer.
* cvfa: activate robust reconfiguration (same as MO action
Configuration.activateRobustReconfiguration)
* cvfd: deactivate robust reconfiguration (same as MO action
Configuration.deactivateRobustReconfiguration)

Command syntax (COM):


* cvcu
* cvls [<cv-filter>]
* cvmk <cvname>
* cvre <cvname>|<cv-Id>
* cvrm <cvname>|<cv-filter>|<cv-Id>
* cvrmu <UP>
* cvget <cvname>|<cv-filter>|<cv-Id> [<destdir>]
* cvgetu <UP>
* cvput <zipped-cvfile>
* cvfa
* cvfd

Command description (COM):


* cvcu : display the current backup information only.
* cvls : same as above plus the list of SwVersions, UpgradePackages and
BrmBackups. The Id field of the BrmBackup can be used in the commands cvrm and
cvget.
* cvmk : create a local backup.
* cvre : restore a backup (equivalent to doing a cvset followed by node restart
on CPP)
* cvrm : remove one or more backups from the node. If the argument does not
match an existing backup then all backups matching that string will be removed. A
confirmation message is printed before removal.
* cvrmu: remove all backups connected to a specific UP (same as cvrm but with
the UP as argument).
* cvget : export a backup to the workstation. The second argument is optional.
If not given, a default folder is chosen for the backup
~/moshell_logfiles/logs_moshell/cv/<node>/<date>_<time>/
* cvgetu: export all backups connected to a specific UP (same as cvget but with
the UP as argument).
* cvput : transfer a backup (zip file) from the workstation to the node.
* cvfa : activate failsafe backup (same as MO action
BrmFailsafeBackup.activate)
* cvfd : deactivate failsafe backup (same as MO action
BrmFailsafeBackup.deactivate)

Examples:
List all CVs
>> cvls
List all CVs using Upgradepackage CXP9011274_R9A
>> cvls CXP9011274_R9A
Create a cv and make it startable (no userid or comments given):
>> cvms RNC11_Final
Create a cv and make it startable (userid and comments given):
>> cvms RNC11_Final eanzmagn cell power increased to 33dBm
Remove all cv's whose name match the string "Temp":
>> cvrm Temp
Remove all cv's whose name don't match the string "Final":
>> cvrm !Final
Remove all cv's whose name don't match the string "final" or the string "RNC":
>> cvrm !Final|RNC
Make a remote backup of a CV to the workstation where moshell is runing:
>> cvget RNC11_Final
Make a remote backup of all CVs whose name matches RNC11.*Fi :
>> cvget RNC11.*Fi
Transfer a remote cv backup from the workstation to the node:
>> cvput /home/eric/RNC11_Final.zip
Remove the oldest 15 CVs:
>> cvrm 1-15
Fetch CV number 3, 5, and 8 from the cv list
>> cvget 3,5,8
Set CV number 23 as startable
>> cvset 23
Remove all CVs/Backups connected to the UP CXP9011274_R9A
>> cvrmu CXP9011274_R9A
Export/fetch all CVs/Backups connected to the UP CXP9011274_R9A
>> cvgetu CXP9011274_R9A
Activate failsafe/robust configuration:
>> cvfa
Deactivate failsafe/robust configuration:
BASEBAND_5216> /homecvput

......ND_5216>
/homecvputr/Cliente/moshell_logfiles/logs_moshell/cv/4GPI4_GALVEZ_QUEROCOTILLO_BACK
UP-2020-08-08T11?02?29+00?
00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip
BASEBAND_5216>cvput/Cliente/moshell_logfiles/logs_moshell/cv/4GPI4_GALVEZ_QUEROCOTI
LLO_BACKUP-2020-08-08T11?02?29+00?
00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip .zip

............................................................
200808-23:04:46 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8
stopfile=/tmp/3167
coli>/homecvput/Cliente/moshell_logfiles/logs_moshell/cv/4GPI4_GALVEZ_QUEROCOTILLO_
BACKUP-2020-08-
08T110229+0000_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip
no such command:
/homecvput/Cliente/moshell_logfiles/logs_moshell/cv/4GPI4_GALVEZ_QUEROCOTILLO_BACKU
P-2020-08-
08T110229+0000_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip
coli>

BASEBAND_5216>

BASEBAND_5216>

BASEBAND_5216>

pASEBAND_5216> cvput
/home/Cliente/moshell_logfiles/logs_moshell/cv/4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-
2020-08-08T11?02?29+00?
00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip

200808-23:07:28 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

$ssh_pid = 3298

Connected to 169.254.2.2 (RadioNode,ManagedElement=BASEBAND_5216)

Last MO: 6527. Loaded 6527 MOs. Total: 6528 MOs.

Starting sshd on port 10624... OK

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
90 BrM=1,BrmBackupManager=1 importBackup
2
>>> Return value = 0

===================================================================================
==============================
Total: 1 MOs attempted, 1 MOs actioned

Waiting 5 seconds before starting to poll...

MO ElapsedTime state progressCount


progressHeader
BrmBackupManager=1 0s 0/100 (0%) The
action could not be completed
BrmBackupManager=1 3s FINISHED 0/100 (0%) The
action could not be completed
Waiting 2 seconds before checking result...
MO ElapsedTime $polp_result $polp_info
BrmBackupManager=1 3s FAILURE

Stopping sshd pid 3314...OK

..
Last MO: 6526. Loaded 6526 MOs. Total: 6527 MOs.

BASEBAND_5216> cvput /home/Cliente/4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-2020-08-08T11?


02?29+00?00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip

200808-23:08:15 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

Last MO: 6526. Loaded 6526 MOs. Total: 6527 MOs.

Starting sshd on port 10288... OK

Stopping sshd pid 3350...OK

Last MO: 6526. Loaded 6526 MOs. Total: 6527 MOs.


BASEBAND_5216> cvput /home/Cliente/4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-2020-08-08T11?
02?29+00?00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip

200808-23:08:47 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

Last MO: 6526. Loaded 6526 MOs. Total: 6527 MOs.

Starting sshd on port 10309... OK

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
90 BrM=1,BrmBackupManager=1 importBackup
2
>>> Return value = null

===================================================================================
==============================
Total: 1 MOs attempted, 1 MOs actioned

Waiting 5 seconds before starting to poll...

MO ElapsedTime state progressCount


progressHeader
BrmBackupManager=1 0s 0/100 (0%) The
action could not be completed
BrmBackupManager=1 3s FINISHED 0/100 (0%) The
action could not be completed
Waiting 2 seconds before checking result...
MO ElapsedTime $polp_result $polp_info
BrmBackupManager=1 3s FAILURE

Stopping sshd pid 3368...OK

....
Last MO: 6525. Loaded 6525 MOs. Total: 6526 MOs.

BASEBAND_5216> cvput /home/Cliente/4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-2020-08-08T11?


02?29+00?00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip

200808-23:09:33 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

Last MO: 6525. Loaded 6525 MOs. Total: 6526 MOs.

Starting sshd on port 10031... OK

Stopping sshd pid 3404...OK

Last MO: 6525. Loaded 6525 MOs. Total: 6526 MOs.

BASEBAND_5216> cvput 4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-2020-08-08T11?02?29+00?


00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip
200808-23:10:06 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8
stopfile=/tmp/3167

Last MO: 6525. Loaded 6525 MOs. Total: 6526 MOs.

Starting sshd on port 10623... OK

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
90 BrM=1,BrmBackupManager=1 importBackup
2
>>> Return value = null

===================================================================================
==============================
Total: 1 MOs attempted, 1 MOs actioned

Waiting 5 seconds before starting to poll...

MO ElapsedTime state progressCount


progressHeader
BrmBackupManager=1 0s Command not found. 0/100 (0%)
BrmBackupManager=1 3s FINISHED 0/100 (0%) The
action could not be completed
Waiting 2 seconds before checking result...
MO ElapsedTime $polp_result $polp_info
BrmBackupManager=1 3s FAILURE

Stopping sshd pid 3423...OK

......
Last MO: 6524. Loaded 6524 MOs. Total: 6525 MOs.

BASEBAND_5216> cvput /4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-2020-08-08T11?02?29+00?


00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200808T230416+0000.zip

200808-23:11:04 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167
Error: zip file not found or invalid !

***********************************************************************************
****
cvls/cvmk/cvms/cvset/cvrm[u]/cvrbrm/cvcu/cvget[f][u]/cvput/cvls1/cvre/cvfa/cvfd
***********************************************************************************
****
CV backup handling: list, make local, make remote, remove, setstartable.

Command syntax (CPP):


* cvcu
* cvls [<cv-filter>]
* cvls1
* cvmk <cvname> [<operator>] [<comment>]
* cvset <cvname>|<cv-Id>
* cvms <cvname> [<operator>] [<comment>]
* cvrm <cvname>|<cv-filter>|<cv-Id>
* cvrmu <UP>
* cvrbrm <cvname>|<cv-filter>|<cv-Id>
* cvget[f] <cvname>|<cv-filter>|<cv-Id> [<destdir>]
* cvgetu <UP>
* cvput <zipped-cvfile>
* cvfa
* cvfd

Command Description (CPP):


A set of commands similar to the "cv" commands in OSE but operate through MO
interface instead of telnet/ssh (ie: no password).
* cvcu: display the current cv information only (equivalent of "cv cu").
* cvls: display both the current cv information (equivalent of "cv cu") and cv
list (equivalent of "cv ls"). It is possible to filter the output of cvls to only
show CVs where the CV name or CV attributes match a certain string. The proxy Id of
the CVs can be used in the commands cvrm and cvget. The display of CV proxy Id can
be disabled with command "safe+".
* cvls1: similar to the cvls command except that it executes via the OSE shell
instead of the MO service.
* cvmk: create a local cv backup. Operator name and comments (not longer than
40 characters) can be given as argument.
* cvset: set a cv as startable.
* cvms: create a cv and make it startable (combination of cvmk and cvset)
* cvrm: remove one or more cv's. If the argument does not match an existing CV
then all CVs matching that string will be removed. A confirmation message is
printed before removal. The CV(s) will automatically be removed from rollback list
when necessary.
* cvrmu: remove all CV's connected to a specific UP (same as cvrm but with the
UP as argument).
* cvrbrm: remove one or more cv's from the rollback list. If the argument does
not match an existing CV then all CVs matching that string will be removed. A
confirmation message is printed before removal.
* cvget[f]: make a remote backup of a cv to the workstation. The operation is
done with the MO action putToFtpServer unless option "f" has been specified, in
which case the transfer will be done by FTP/SFTP. The second argument is optional.
If not given, a default folder is chosen for the backup
~/moshell_logfiles/logs_moshell/cv/<node>/<date>_<time>/
* cvgetu : make a remote backup of all CVs connected to a specific UP (same as
cvget but with the UP as argument).
* cvput: transfer a remote CV backup (zip file) from the workstation to the
node. The operation is done with the MO action getFromFtpServer.
* cvfa: activate robust reconfiguration (same as MO action
Configuration.activateRobustReconfiguration)
* cvfd: deactivate robust reconfiguration (same as MO action
Configuration.deactivateRobustReconfiguration)

Command syntax (COM):


* cvcu
* cvls [<cv-filter>]
* cvmk <cvname>
* cvre <cvname>|<cv-Id>
* cvrm <cvname>|<cv-filter>|<cv-Id>
* cvrmu <UP>
* cvget <cvname>|<cv-filter>|<cv-Id> [<destdir>]
* cvgetu <UP>
* cvput <zipped-cvfile>
* cvfa
* cvfd
Command description (COM):
* cvcu : display the current backup information only.
* cvls : same as above plus the list of SwVersions, UpgradePackages and
BrmBackups. The Id field of the BrmBackup can be used in the commands cvrm and
cvget.
* cvmk : create a local backup.
* cvre : restore a backup (equivalent to doing a cvset followed by node restart
on CPP)
* cvrm : remove one or more backups from the node. If the argument does not
match an existing backup then all backups matching that string will be removed. A
confirmation message is printed before removal.
* cvrmu: remove all backups connected to a specific UP (same as cvrm but with
the UP as argument).
* cvget : export a backup to the workstation. The second argument is optional.
If not given, a default folder is chosen for the backup
~/moshell_logfiles/logs_moshell/cv/<node>/<date>_<time>/
* cvgetu: export all backups connected to a specific UP (same as cvget but with
the UP as argument).
* cvput : transfer a backup (zip file) from the workstation to the node.
* cvfa : activate failsafe backup (same as MO action
BrmFailsafeBackup.activate)
* cvfd : deactivate failsafe backup (same as MO action
BrmFailsafeBackup.deactivate)

Examples:
List all CVs
>> cvls
List all CVs using Upgradepackage CXP9011274_R9A
>> cvls CXP9011274_R9A
Create a cv and make it startable (no userid or comments given):
>> cvms RNC11_Final
Create a cv and make it startable (userid and comments given):
>> cvms RNC11_Final eanzmagn cell power increased to 33dBm
Remove all cv's whose name match the string "Temp":
>> cvrm Temp
Remove all cv's whose name don't match the string "Final":
>> cvrm !Final
Remove all cv's whose name don't match the string "final" or the string "RNC":
>> cvrm !Final|RNC
Make a remote backup of a CV to the workstation where moshell is runing:
>> cvget RNC11_Final
Make a remote backup of all CVs whose name matches RNC11.*Fi :
>> cvget RNC11.*Fi
Transfer a remote cv backup from the workstation to the node:
>> cvput /home/eric/RNC11_Final.zip
Remove the oldest 15 CVs:
>> cvrm 1-15
Fetch CV number 3, 5, and 8 from the cv list
>> cvget 3,5,8
Set CV number 23 as startable
>> cvset 23
Remove all CVs/Backups connected to the UP CXP9011274_R9A
>> cvrmu CXP9011274_R9A
Export/fetch all CVs/Backups connected to the UP CXP9011274_R9A
>> cvgetu CXP9011274_R9A
Activate failsafe/robust configuration:
>> cvfa
Deactivate failsafe/robust configuration:
>> cvfd
BASEBAND_5216> cvls

200808-23:12:25 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

Last MO: 6525. Loaded 6525 MOs. Total: 6526 MOs.

=============================================
200808-23:12 BackupName SwVersion
=============================================
LastCreatedBackup:
LastRestoredBackup:
---------------------------------------------
Current SwVersion:
BrmHouseKeeping:
BrmFailSafe:
RestoreEscalationList:
===================================================================================
==============
SwVersion ProductData ProdDate Rel LMs InstallationDate ActivationDate
DeactivationDate
===================================================================================
==============
===================================================================================
==============
UpgradePackage ProductData ProdDate Rel CreationDate State
===================================================================================
==============
CXP9024418/6-R28U20
===================================================================================
==============
Id BackupName CreationTime SwVersion Rel Type Stat MO
===================================================================================
==============
===================================================================================
==============
>>> Total: 0 CV's, 1 UP's

BASEBAND_5216> cvput
/home/Cliente/moshell_logfiles/logs_moshell/cv/4GPI4_GALVEZ_QUEROCOTILLO_BACKUP-
2020-08-
01T11_00_00+00_00_4GPI4_GALVEZ_QUEROCOTILLO_RadioNode_20200801T110010+0000.zip

200808-23:33:55 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

$ssh_pid = 3453

Connected to 169.254.2.2 (RadioNode,ManagedElement=BASEBAND_5216)

Last MO: 6527. Loaded 6527 MOs. Total: 6528 MOs.

Starting sshd on port 10898... OK

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
90 BrM=1,BrmBackupManager=1 importBackup
2
>>> Return value = 0

===================================================================================
==============================
Total: 1 MOs attempted, 1 MOs actioned

Waiting 5 seconds before starting to poll...

MO ElapsedTime state progressCount


progressHeader
BrmBackupManager=1 0s RUNNING 98/100 (98%) Import
complete
BrmBackupManager=1 4s FINISHED 100/100 (100%) Import
complete
Waiting 2 seconds before checking result...
MO ElapsedTime $polp_result $polp_info
BrmBackupManager=1 4s SUCCESS
BrM=1,BrmBackupManager=1,BrmBackup=3

Stopping sshd pid 3469...OK

Last MO: 6528. Loaded 6528 MOs. Total: 6529 MOs.

BASEBAND_5216> cvls

200808-23:35:01 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

===================================================================================
========
200808-23:35 BackupName SwVersion
===================================================================================
========
LastCreatedBackup:
LastRestoredBackup:
-----------------------------------------------------------------------------------
--------
Current SwVersion: CXP9024418/6_R28U20 (17B)
BrmHouseKeeping: ENABLED (max: 20 backups)
BrmFailSafe: IDLE
RestoreEscalationList: s[1] = Auto integration backup - SITE_CONFIG_COMPLETE
===================================================================================
=====================================
SwVersion ProductData ProdDate Rel LMs InstallationDate
ActivationDate DeactivationDate
===================================================================================
=====================================
CXP9024418/6-R28U20 CXP9024418/6_R28U20 20190619 17B 76 2020-08-09 03:47:48
2020-08-09 03:53:33
===================================================================================
=====================================
UpgradePackage ProductData ProdDate Rel CreationDate State
===================================================================================
=====================================
CXP9024418/6-R28U20 CXP9024418/6_R28U20 20190619 17B 2020-08-09 03:47:46
COMMIT_COMPLETED
===================================================================================
=====================================
Id BackupName CreationTime SwVersion
Rel Type Stat MO
===================================================================================
=====================================
1 BACKUP-2020-08-01T11:00:00+00:00 2020-08-01 11:00:00
CXP9024418/6_R28U20 17B MANUAL OK BrmBackup=3
2 Auto integration backup - SITE_CONFIG_COMPLETE 2020-08-09 03:49:13
CXP9024418/6_R28U20 17B SYSCR OK BrmBackup=2
===================================================================================
=====================================
>>> Total: 2 CV's, 1 UP's

BASEBAND_5216> cvre 1

200808-23:35:28 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

Restore following backup?


===================================================================================
=======================
1 BACKUP-2020-08-01T11:00:00+00:00 2020-08-01 11:00:00
CXP9024418/6_R28U20 17B MANUAL OK BrmBackup=3
===================================================================================
=======================
Restore will cause node restart and loss of any configuration data that has not
been saved in a backup.
If in doubt, save a backup (cvmk) before proceeding.
Are you Sure [y/n] ? y

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
92 BrM=1,BrmBackupManager=1,BrmBackup=3 restore
0
>>> Return value = 0

===================================================================================
==============================
Total: 1 MOs attempted, 1 MOs actioned

Waiting 5 seconds before starting to poll...

MO ElapsedTime state progressCount


progressHeader
BrmBackup=3 0s RUNNING 1/100 (1%) Restoring
BACKUP-2020-08-01T11:00:00+00:00
BrmBackup=3 4s RUNNING 24/100 (24%) Preparing
restore database
BrmBackup=3 8s RUNNING 24/100 (24%) Preparing
restore database
BrmBackup=3 11s RUNNING 24/100 (24%) Preparing
restore database
BrmBackup=3 15s RUNNING 55/100 (55%) Backup
restored. Rebooting...
BrmBackup=3 19s RUNNING 55/100 (55%) Backup
restored. Rebooting...
BrmBackup=3 22s RUNNING 55/100 (55%) Backup
restored. Rebooting...
BrmBackup=3 26s RUNNING 55/100 (55%) Backup
restored. Rebooting...
BrmBackup=3 29s COM.NO_CONTACT 0/100 (0%)
COM.NO_CONTACT
BrmBackup=3 44s COM.NO_CONTACT 0/100 (0%)
COM.NO_CONTACT
BrmBackup=3 78s (01m18s) COM.NO_CONTACT 0/100 (0%)
COM.NO_CONTACT

$ssh_pid = 3568

Connected to 169.254.2.2 (RadioNode,ManagedElement=4GPI4_GALVEZ_QUEROCOTILLO)


ManagedElement Id has changed, reloading MO list...

Last MO: 8959. Loaded 8959 MOs. Total: 8960 MOs.


BrmBackup=3 102s (01m42s) COM.NO_CONTACT 0/100 (0%) Backup
restored. Rebooting...
BrmBackup=3 125s (02m05s) FINISHED 100/100 (100%) Backup
restored. Rebooting...
Waiting 2 seconds before checking result...
MO ElapsedTime $polp_result $polp_info
BrmBackup=3 125s (02m05s) SUCCESS The backup restore is
complete
Connected to 169.254.2.2 (RadioNode,ManagedElement=4GPI4_GALVEZ_QUEROCOTILLO)

Last MO: 8964. Loaded 8964 MOs. Total: 8965 MOs.

Checking MOM version...MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


Parsing MOM (cached):
/home/Cliente/moshell_logfiles/logs_moshell/tempfiles/20200808-
224947_3144/MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8.xml.cache.gz .................
...................................................................................
...Done.
Using paramfile /home/Cliente/moshell/commonjars/pm/PARAM_MSRBS_16B.txt
Parsing file
/home/Cliente/moshell/commonjars/pm/PARAM_MSRBS_16B.txt ...........................
......Done.
Using imomdfile /home/Cliente/moshell/commonjars/pm/IMOMD_MSRBS_16B.txt
Using imomfile /home/Cliente/moshell/commonjars/pm/IMOM_MSRBS_16B.txt

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
1835 BrM=1,BrmRollbackAtRestore=1
confirmRestore 0
>>> Return value = 0

===================================================================================
==============================
Total: 1 MOs attempted, 1 MOs actioned

Waiting 5 seconds before starting to poll...

MO ElapsedTime state progressCount


progressHeader
BrmBackup=3 0s FINISHED 100/100 (100%) Backup
restored. Rebooting...
Waiting 2 seconds before checking result...
MO ElapsedTime $polp_result $polp_info
BrmBackup=3 0s SUCCESS The backup restore is
complete

BASEBAND_5216> st FieldReplaceableUnit

200808-23:42:35 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

$ssh_pid = 3615

Connected to 169.254.2.2 (RadioNode,ManagedElement=4GPI4_GALVEZ_QUEROCOTILLO)


===================================================================================
Proxy Adm State Op. State MO
===================================================================================
1684 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=1
1719 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-1
1728 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-2
1737 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-3
1746 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-4
1753 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-5
1760 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-6
1767 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-7
1776 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-8
1785 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-9
===================================================================================
Total: 10 MOs

BASEBAND_5216> acl 1684

200808-23:43:06 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
1684 FieldReplaceableUnit=1
resetUnitInstallation 0
1684 FieldReplaceableUnit=1 restartUnit
3
1684 FieldReplaceableUnit=1
writeRepairDelivNote 6
===================================================================================
==============================

BASEBAND_5216> acc 1684restartUnit


200808-23:43:35 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8
stopfile=/tmp/3167

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
===================================================================================
==============================
Total: 0 MOs attempted, 0 MOs actioned

BASEBAND_5216> acc 1684 restartUnit

200808-23:44:23 169.254.2.2 17.0b MSRBS_NODE_MODEL_17.Q4_346.27777.46_e0e8


stopfile=/tmp/3167
Call Action restartunit on following 1 MOs ?
===================================================================================
1684 Equipment=1,FieldReplaceableUnit=1
===================================================================================
INFO: The RBS node BASEBAND_5216 will be restarted.
REMINDER: If the node is being restarted to clear a fault, please make sure to run
"dcge" or "dcgm" BEFORE the node restart.
Call action restartunit on 1 MOs. Are you Sure [y/n] ? y

===================================================================================
==============================
Proxy MO Action
Nr of Params
===================================================================================
==============================
1684 FieldReplaceableUnit=1 restartUnit
3

Parameter 1 of 3, restartRank (enumRef-ReqFieldReplaceableUnit.RestartRank):


Enter one of the following integers: 0:RESTART_WARM, 1:RESTART_COLD,
2:RESTART_COLDWTEST: 2

Parameter 2 of 3, restartReason (enumRef-ReqFieldReplaceableUnit.RestartReason):


Enter one of the following integers: 0:PLANNED_RECONFIGURATION,
1:UNPLANNED_NODE_EXTERNAL_PROBLEMS, 2:UNPLANNED_NODE_UPGRADE_PROBLEMS,
3:UNPLANNED_O_AND_M_ISSUE, 4:UNPLANNED_CYCLIC_RECOVERY,
5:UNPLANNED_LOCKED_RESOURCES, 6:UNPLANNED_COLD_WITH_HW_TEST,
7:UNPLANNED_CALL_PROCESSING_DEGRADATION, 8:UNPLANNED_LOW_COVERAGE,
31:OPERATOR_CLASSIFIED_PROBLEMS: 0

Parameter 3 of 3, restartInfo (string): cliente


>>> Return value = null

===================================================================================
==============================
Total: 1 MOs attempted, 1 MOs actioned

BASEBAND_5216>