Area 01 – Reception/ Front Desk Area

If your clients want to impress, the office reception is the place to start. Visitors will make decisions
about your client’s company based on their initial reaction. It goes without saying that the
atmosphere should be welcoming, but it should also reflect the way they do business. Lighting can
help set the mood perfectly – from fun and funky to cool and corporate, enhancing the expectations
of clients and customers. It also creates the right welcome for staff.

Task lighting to counter top (using Ceiling recessed light fitting) - Area = 6 m2 (approx.)

Recommended Lux level = 300 lx (EN 12464)

Lumen requirement = 300 x 6 = 1800 lm

Proposed Light fitting - Philips Electric/ LED Reflector lamp R-20 / product number 42881-3(530 lx )

Nr. of units required - 1800/530 ≈ 3 Nr

Focal lighting for textured backdrop wall (using wall mounted light fitting)

For an aesthetic appearance

Proposed Light fitting-Philips Electric/Led MR 16 Lamps Product Number 42039-8(290 lx)

Nr. of units - 2 nr (to balance lighted area)

Area 02 – Meeting Room

Lighting has a profound effect on the way people feel. Tailor the lighting to suit the agenda and your
client’s meeting rooms become far more effective spaces. Light can enhance well-being, create
excitement or provide an air of concentration. Our innovative solutions take lighting to new levels of
sophistication, with clever features that bring out the best in your client’s meeting rooms and the
people who use them

using Ceiling down light fitting - Area = 30 m2 (approx.)

Recommended Lux level = 500 lx (EN 12464)

Lumen requirement = 500 x 30 = 15000 lm

Proposed Light fitting - Philips Electric/ LED T8 Specifier series/product no-42719-5 (2500lx)

Nr. of units required - 15000/2500 ≈ 6 Nr


Focal lighting for wall decorations (using wall mounted light fitting)

For an aesthetic appearance

Proposed Light fitting-Philips Electric/LED PAR16 GU10 Lamps/Product no-42350-9 (300lx)

Nr. of units - 6 nr (to balance lighted area)

Area 03 – Open Plan Office

Open plan offices are dynamic spaces where people need to carry out a wide variety of different
tasks. Lighting can create a comfortable ambience by combining functional lighting with inspiring
light effects. Add individual controls and the light can be personalized at each desk. So whatever
your client’s staff are working on, business is a pleasure.

using Ceiling down light fitting - Area = 44 m2 (approx.)

Recommended Lux level = 500 lx (EN 12464)

Lumen requirement = 500 x 44 = 22000 lm

Proposed Light fitting - Philips Electric/ LED T8 G13 Specifier series/product no-42183-4 (1650lx)

Nr. of units required - 22000/1650 ≈ 13 Nr

Focal lighting for wall decorations (using wall mounted light fitting)

For an aesthetic appearance

Proposed Light fitting-Philips Electric/LED MR 16 Lamps/Product no-41474-8 (405lx)

Nr. of units - 6 nr (to balance lighted area)

Area 04– Manager Room

Cell offices and Manager rooms provide welcome peace and quiet from busy office life. But
sometimes they have only limited natural light and leave people feeling out of touch with the world
outside the office walls. The right lighting dynamics can help to produce a comfortable working
ambience and create a sense of well-being.
using Ceiling down light fitting - Area = 8 m2 (approx.)

Recommended Lux level = 500 lx (EN 12464)

Lumen requirement = 500 x 8 = 4000 lm

Proposed Light fitting - Philips Electric/ LED PAR 38 Lamps/product no-41855-8 (1050lx)

Nr. of units required - 4000/1050 ≈ 4 Nr

Area 05 - Pantry
With its heavy focus on the functions of food preparation and cleanup, as well as its tendency
to be a gathering spot, the pantry requires careful consideration of task and ambient lighting.
Think in particular of the task lighting for the counters, where most of the work takes place,
and over the sink.

One of the main reasons sinks have often been located at a window is to take advantage of
natural light, and this layout is still highly recommended by lighting experts. Augment the
natural light with a ceiling mounted or recessed fixture above the sink. Using undercabinet
lighting is a good way to illuminate the countertop work surfaces without relying on an
overhead light that will cast shadows on the person working at the counters.

using Ceiling down light fitting - Area = 7.5 m2 (approx.)

Recommended Lux level = 300 lx (EN 12464)

Lumen requirement = 300 x 7.5 = 2250 lm

Proposed Light fitting - Philips Electric/ LED PAR 38 Lamps/product no-41855-8 (1050lx)

Nr. of units required - 2250/1050 ≈ 2 Nr

Area 06 – Bathroom

With its emphasis on personal grooming that requires viewing oneself in a mirror, the bathroom
requires careful consideration of lighting placement. Too many bathrooms feature a central ceiling-
mounted fixture that casts shadows on a person standing in front of the mirror. "One of the best
improvements you can make in a bathroom is to light both sides of the mirror," says Patricia Rizzo of
the Lighting Research Center. In small baths, where one may have to choose between a wall-
mounted fixture on the side of the mirror or an overhead fixture, lighting designers say to always go
with the wall-mounted placement. "You don't want to cause shadows in a bathroom," says Rizzo.
using Ceiling down light fitting - Area = 4.7 m2 (approx.)

Recommended Lux level = 200 lx (EN 12464)

Lumen requirement = 200 x 4.7 = 940 lm

Proposed Light fitting - Philips Electric/ LED PAR 20 Lamps/product no-42612-2 (450lx)

Nr. of units required - 940/450 ≈ 2 Nr

Area 07-Toilet
This provides light from all sides that minimizes shadows under the chin, eyes, cheeks, and forehead.
... Avoid using ceiling mounted fixtures as the sole source unless the room is very small with light
colored walls. Large bathrooms often need additional lighting besides the mirror lighting.

using Ceiling down light fitting - Area = 1.4 m2 (approx.)

Recommended Lux level = 200 lx (EN 12464)

Lumen requirement = 200 x 1.4 = 280 lm

Proposed Light fitting - Philips Electric/ LED mr16 Lamps 5.5 MR16/ product no-42039-8 (290lx)

Nr. of units required - 280/290 ≈ 1 Nr

Area 08-Nameboard
Led name boards are very good for bringing in a lot of business. Led name boards are very latest
technology and this technology is most widely used in many offices and companies. The led name
boards are good because they are high in density and emits bright light. The led light can be visible
from far away and it is also very visible in pitch dark night. The led name board also gives a good
running text and text styles The led name boards with many colors gives a good design and it is one
of the best way to promote your business. Led signages are very much used in hotels and restaurant.
Led displays are also used in exhibitions, trade centers and other places. Led walls are fixed and live
relays and presentation are provided. Our led name board manufacturers and dealers in Chennai
provide to the suppliers at a very lower cast. Multi color led lights used in boards is the best and
different way to promote your company.

light fitting - Area = 4.5m2 (approx.)

Recommended Lux level = 800 lx (EN 12464)

Lumen requirement = 800 x 4.5 = 3600 lm

Proposed Light fitting - Philips Electric/ LED T8 G13 Specifier series/product no-42183-4 (1650lx)

Nr. of units required - 3600/1650 ≈ 2 Nr