You are on page 1of 239

2JC-2384

Messrs. YAMANISHI CORPORATION


S.No.1085

MODEL: JCY-1800
VOYAGE DATA RECORDER

FINISHED DRAWING

21 May 2010

Product Engineering Group


Engineering Department
Marine Electronics Division
TEL 0422-45-9061
FAX 0422-45-9957

checked by in charge
CONTENTS

1. Components List

2. Features

3. Specifications

4. Interface List
List of Ship’s Information
List of Equipment and Connection Interface
List of Audio Signal Equipment
List of Video Signal Equipment

5. System Block Diagrams

6. Interconnection Wiring Drawings


NDV-1800 Recording Control Unit
NQE-3163 Connection Box
NCG-169 Operation Panel Unit
NVT-161 Microphone Unit
VHF Radio Telephone connection (Reference)
NCT-72 Digital Signal Converter (64CH)

7. Schematic Diagrams
NDV-1800 Recording Control Unit
NCG-169 Operation Panel Unit
NVT-161 Microphone Unit
NCT-72 Digital Signal Converter (64CH)

8. Outline Drawings
NDH-316A Protective Capsule
NQE-3163 Connection Box
NDV-1800 Recording Control Unit
NCG-169 Operation Panel Unit
NVT-161 Microphone Unit
NCT-72 Digital Signal Converter (64CH)

9. Mechanical Installation Guideline

10. Spare Parts List


For NDV-1800 Recording Control Unit
For NCT-72 / 63 Digital Signal Converter
1. Components List

Table of standard Components for VDR Model JCY-1800


Mass
No Name Type Quantity Remarks
1Unit (kg)
Manufactured by L-3
1 Protective Capsule Unit NDH-316A 1 7.9
Fixed type.
2 Connection Box NQE-3163 1 1.3

3 Recording Control Unit NDV-1800 1 23.0

4 Operation Panel Unit NCG-169 1 0.3

5 Microphone Unit NVT-161 3 0.2

6 Spare Parts for the RCU 7ZXJD0080 1 0.3 For the NDV-1800.
Only for the
Investigation Authorities.
7 Playback software CYC-315A 1 ---
Attached inside the
NDV-1800.
For the User.
Playback Software /
8 CYC-316A 1 ---
Real Time Monitor Attached inside the
NDV-1800.

Table of option Components for VDR Model JCY-1800


Mass
No Name Type Quantity Remarks
1Unit (kg)
1 Digital Signal Converter (64CH) NCT-72 1 5.0 For 64 Dry Contacts

2 Spare Parts for the DSC 7ZXJD0092 1 0.03 For the NCT-72 / 63

3 Waterproof Ethernet Cable H-7ZCAF0200 10m --- Category 5

4
2. Features

a) Fully Comply with International Regulations on IMO A.861, IEC61996, IEC60945.

b) Recording data to the protective capsule unit


1) Date and Time
2) Ship’s position via EPFS
3) Ship’s speed (Water speed or ground speed)
4) Ship’s heading
5) Under keel Clearance
6) RADAR image data
7) VHF communication audio
8) On the Bridge audio
9) Main alarms on the bridge
10) Rudder order and response
11) Engine order and response
12) Hull openings status (RORO passenger only)
13) Watertight and fire door status
14) Acceleration/HULL stress (IMO mandated vessel only)
15) Wind direction and speed (if fitted)
3. Specifications

3.1 Protective Capsule Unit: PCU (NDH-316A)

(1) Function:
The protective capsule unit (PCU) should record navigation data, physical status, and
conversation on the bridge, VHF communications audio, and radar image data
-post-display to the recording medium in the protective capsule.
When submerged, the underwater acoustic beacon with protective capsule, which is a
battery-powered device, transmits a pulsed acoustic signal for search operation in water.

(2) Performance:
a) Interface:
1) Standard: IEEE802.3 (10Base-T/ 100Base-TX)
2) Protocol: TCP/IP
b) Recording duration and capacity:
1) Duration: 12 hours
2) Capacity: 2.0GB (flash memory)
c) Data Recording Interval:
1) Sensor Data: depends on the input from the sensors (usually 1 second)
2) Audio Data: continuous (1 audio file / minute)
3) Image Data: 1 image per 15 second
d) Acoustic underwater beacon:
1) Operating frequency: 37.5kHz ±1kHz
2) Operating time: min. 30 days after being immersed in the water
3) Detectable range: 1800m - 3600m
(depending on surrounding environment, e.g. sea state,
nearby boats, marine animals and other factor)
4) Expectant battery age: max 5-years

(3) Environmental condition


The recording data in the final recording medium shall be held without loss under below
the condition.
a) Shock: A half sine-wave pulse of 50 G, with a duration of 11msec
b) Penetration: A mass of 250 kg with a pin of 100mm diameter, dropped
from 3m
c) Fire: A low temperature fire of 260deg. nominal for 10 h
A high temperature fire of 1100deg. nominal for 1 h
d) Deep-sea pressure and Immersion in sea water at pressure of 60 Mpa
immersion: (equivalent to a depth of 6000m)
General environmental condition
e) Operating temperature: -25deg. to +55deg. (IEC 60945 exposed type)
f) Storage temperature -55deg. to +70deg. (IEC 60945 exposed type)
g)Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G

(4) General specification


a) Input voltage range: 19.5 - 36.5Vdc
b) Power consumption: 3W
c) Size: 186(W) x 209(D) x 217(H) mm
d) Mass: 7.9kg
e) Color: fluorescent orange
3.2 Recording Control Unit: RCU (NDV-1800)

3.2.1 Operation panel (Internal)

(1) Performance:
a) Button operation:
1) Recording stop: stop to record data to PCU
2) Recording restart: restart to record data to PCU
3) Card recording stop: enable to eject CF card from RCU
b) LEDs Indication:
1) Recording status Recording / Recording stop
2) CF card status Recording / Recording stop (enable to eject CF card)
3) CF card Media error Access error to CF card

3.2.2 Data Processor Unit

(1) Function:
a) Recording control for navigation and physical-status data to PCU.
b) Collecting data on navigation and hull condition according to IEC61162-1/2.
The collected data are as follows according to the IEC61996 4.6 (IMO A.861/5.4)).
1) Date and Time (UTC)
2) Ship’s position measured by the electronic position fixing system
3) Ship’s speed (over ground/water)
4) Ship’s heading with a gyrocompass or magnetic compass
5) Under keel clearance
6) Main alarms (indicated in the bridge)
7) Rudder order and response data
8) Engine order and response data
9) Hull opening status (only for RO-RO passenger ships and ferry ships)
10) Watertight door / Fire door status
11) Bow acceleration and hull stress data
(Only for the ships mandated by IMO)
12) Wind direction / wind speed data
(only when equipped with measurement devices)
c) Capturing, encoding and recording of conversation audio on the bridge, VHF
communications audio and radar image data -post-display.
d) Copying the recording data to the CF card.
e) System monitoring.

(2) Performance:
a) Communication to PCU:
1) Standard: IEEE802.3 (10Base-T/ 100Base-TX )
2) Protocol: TCP/IP
b) Sensor data input :
1) Input channel: up to 32 (channels)
2) Data input interface: IEC61162-1/-2 (RS-422)
3) Recording interval: depends on the input from the sensors (usually 1 second)
c) Bridge audio input:
1) Input channel: up to 9 (channels)
2) Input sensibility: 6kHz
3) Recording interval: continuous (1 audio file / minute)
d) VHF communications input (audio):
1) Input channel: up to 3 (channels)
2) Input sensibility: 3.5kHz
3) Input revel: 0 dBm 600-ohm balance
4) Recording interval: continuous (1 audio file / minute)
e) Radar image data input (Recommendation of using No1. X band radar):
1) Input channel: 2 (channels)
Auto selection of a radar image from both channels
(JRC radar: The active radar is selected.)
2) Input interface: analog RGB/Hs/Vs
- RGB: 0.7Vp-p (video signal)
- Hs: TTL
- Vs: TTL
3) Resolution: 640 x 350 – 1600 x 1200 pixel (according to VESA
DMTS)
4) Refresh rate: 60 - 85 Hz (according to VESA DMTS)
(Resolution 1600 x 1200 pixel 60Hz only)
5) Recording interval: 1 image every 15 seconds
f) Recording data backup:
1) Media: CF card
(Adapter for PCMCIA type-2 is attached to the RCU.)
2) Storage capacity: 2.0GB
g) Blackout processing:
1) Recording duration: 2 hours while blackout
(only bridge conversation etc. except VHF
communication)
2) Restoration time required: less than 1 minute
(Recovery time from blackout operation to normal
operation on restoration of power supply)
h) GPS select signal input:
1) Interface: Dry (voltage free) contact closure
(also serve for External Contact Input )
2) Operation: Recording GPS selection (active open/close)
i) RADAR select signal input:
1) Interface of JRC radar: IEC61162-1 (RS-422)
2) Operation of JRC radar: Active radar selection by JRC original sentence
3) Interface of other radar: Dry (voltage free) contact closure
4) Operation of other radar: Recording RADAR selection (active open/close)
j) External Contact Input (dry contact):
1) Number of input: maximum 3 dry contacts (voltage free)
(also serve for select input signals from Radar or GPS)
2) Output sentences: To register sentences at the time of their making and
opening
3.2.3 Power Supply Unit: PSU

(1) Function:
a) Power supply to RCU and PCU in normal operation
b) Power supply to RCU and PCU for 2 hours on blackout.

(2) Performance:
a) Input voltage range: 100 - 120Vac +/- 10% 1-phase 50/60Hz +/-5%
200 - 240Vac +/- 10% 1-phase 50/60Hz +/-5%
(Auto switching)
b) Output voltage: 5Vdc, 12Vdc, 24Vdc
c) Maximum power output: 140VA
d) Battery capacity: 24Vdc 5Ah
e) Expectant battery age: max 4-years
(Depending on circumstance. This age is based on
ambient operating temperature: 25 deg., load 70%)

3.2.4 External interface

a) External alarm lamp output:


1) Interface: Dry (voltage free) contact closure
2) Operation: System down (normal-close or open)
3) Current: 1A or less at 24Vdc / 0.5A or less at 125Vac
b) External alarm buzzer output:
1) Interface: Dry (voltage free) contact closure
2) Operation: System down (normal-close or open)
3) Current: 1A or less at 24Vdc / 0.5A or less at 125Vac

3.2.5 Environmental condition

(1) Operating temperature: -15 deg. to +55 deg. (IEC 60945 protected type)
(2) Temperature and humidity: +40°C, 93% (non condensing)
(3) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G

3.2.6 General specification

(1) Power voltage: 100 - 120Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
(2) Power consumption:
(including capsule unit & operation panel unit & microphone phantom power)
90VA in UPS battery charge
50VA in normal operation
(3) Size: 419.5(w) x 250(d) x 480(h) mm
(4) Mass: 23.0kg
(5) Color: N7 semi-gloss texture
3.2.7 Optional NSK interface (When the optional NSK interface board is added.)

(1) Function: To record gyro compass signal (Synchro / Step) and/or


Ship’s speed log signal as IEC61162-1 sentence formatter
(2) Performance:
a) Signal input: Synchro signal for Gyro compass
Ratio: 360X, 180X, 90X, 36X, 1X
Primary voltage: AC50 – 115V, 50/60Hz
Secondary voltage: AC20 – 90V, 50/60Hz
Step signal for Gyro compass
Ratio: 360X, 180X, 90X, 36X, 1X
Voltage: DC35V / 50V / 70V
Pulse signal for speed log
Ratio: 200P / 400P / 100P / 160P
Interface: Photo-coupling / dry contact signal
b) Recoding data: Data type: IEC61162-1
Heading Sentence formatter: HDT
Ship speed Sentence formatter: VBW

3.3 Connection Box (NQE-3163)

(1) Function: Waterproofed type junction box which connects RCU with
a PCU.
(2) Performance:
a) Connection device: Built-in terminal blocks
(3) Environmental condition:
a) Operating temperature: -25 deg. to +55 deg. (IEC 60945 exposed type)
b) Temperature and humidity: +40°C, 93% (non condensing)
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
d) Waterproof grade: IPx6
(4) General specification
a) Size: 170(w) x 176(d) x 87(h) mm
b) Mass: 1.3kg
c) Color: 7.5BG 7/2
3.4 Operation Panel Unit: OPU (NCG-169)

(1) Function: Visible indication and audible alarm for VDR system alarm
in the Wheelhouse
Display of the cause of an error
Entry of a Heading initial value
(2) Performance:
a) Type: Flush mount type or Wall mount type
b) Power supply: supplied from the recording control unit NDV-1800
c) Indication: LED lighting for alarm indication
4 digits LED for error code indication
Buzzer (mutable by ACK switch)
d) Operation: Alarm acknowledgement
Dimmer of LED
(3) NSK operation: (When the optional NSK interface board is added.)
a) Operation Entry the initial value of heading
b) Indication Heading value indication
(4) Environmental condition:
a) Operating temperature: -15 deg. to +55 deg. (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93% (non condensing)
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(5) General specification:
a) Size: 145(w) x 50(d) x 165(h) mm
b) Mass: 0.3kg
c) Color: N4 semi-gloss texture

3.5 Microphone Unit (NVT-161)

(1) Function: Acquisition of W/H conversation. Alarms and sounds etc.


in W/H
(2) Performance:
a) Type: Ceiling mount type, wall mount type
b) Device: Electoret condenser microphone
c) Directivity: Hemisphere indirectivity
d) Range of Receive: Radius of 2.5m
e) Power supply: Phantom powered by 12Vdc
f) Test device: Built-in speaker for audio acquisition test
(3) Environmental condition:
a) Operating temperature: -15 deg. to +55 deg. (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93% (non condensing)
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(4) General specification
a) Size: 110(w) x 44.5(d) x 160(h) mm
b) Mass: 0.2kg
c) Color: N4 semi-gloss texture
3.6 Digital Signal Converter (NCT-72) 64CH

(1) Function: The Digital signal converter should acquire alarms or


status condition via dry contact closure.
(2) Performance:
a) Dry contact Input port: Dry (voltage free) contact closure
Max. 64 port
b) Contact closure interface:
1) Driving power supply: +12Vdc
2) Status: Normal Close / Normal open (set in JRC plant at shipping)
c) Communication port To the NDV-1800 RCU
d) Data output interface Data type: IEC61162-1
(3) Optional Analog interface: (When the optional Analog signal converting board CEF-60
is added.)
a) Analog signal Input port: Max. 8 port
b) Signal input:
1) Voltage: +/-500mV, +/-5V, +/-10V
2) Current: +/-20mA
c) Communication port Same port as dry contact signals
d) Data output interface Data type: IEC61162-1
Analog Sentence formatter: XDR
(4) Environmental condition:
a) Operating temperature: -15 deg. to +55 deg. (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93% (non condensing)
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(5) General specification
a) Power voltage: 100 - 120Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
b) Power consumption: 25VA
c) Size: 300(w) x 130(d) x 420(h) mm
d) Mass: 5kg
e) Color: N7 semi-gloss
3.7 General Environmental Condition

3.7.1 Location

a) Usage Conditions:

Target vessels: Mercantile vessels of 3000G/T or more that are engaged in


international voyage

b) Unit installation locations:

1) The Protective Capsule Unit: External deck above bridge


2) The Connection Box: External deck above bridge
3) The Recording Control Unit: Bridge (or electronic room)
4) The Operation Panel Unit: Navigation space in a Bridge
5) The Microphone Unit: Ceiling or bulkhead
6) The Waterproof Microphone Unit: Wings
7) The Digital Signal Converter: Bridge (or electronic room)
8) The Radar Interface Unit: near the Radar

c) Installation methods:

1) The Protective Capsule Unit: Mounted on the deck


2) The Connection Box: Mounted on the deck
3) The Recording Control Unit: Hung on the bulkhead
4) The Operation Panel Unit: Hung on the bulkhead
5) The Microphone Unit: Ceiling or bulkhead
6) The Waterproof Microphone Unit: Hung on the bulkhead
7) The Digital Signal Converter: Hung on the bulkhead
8) The Radar Interface Unit: Mounted on the Radar

3.7.2 Power supply environment

a) AC power supply input range:

1) AC100/110/115/120V ±10%
2) AC200/220/240V ±10%

b) AC power supply frequency fluctuation range:

1) 50Hz ±5%
2) 60Hz ±5%
3.7.3 Environment

a) Exposed type equipment


(Protective Capsule Unit, Waterproof Microphone Unit)
1) Operation temperature range: -25°C to +55°C
2) Storage temperature: -25°C to +70°C
3) Temperature and humidity: +40°C, 93% (non condensing)
4) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
b) Protected type equipment
(Recording Control Unit, Operation Panel Unit, Microphone Unit, Option Unit)
1) Operation temperature range: -15°C to +55°C
2) Temperature and humidity: +40°C, 93% (non condensing)
3) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
4. Interface List
4.1. LIST OF SHIP’S INFORMATION
4.1.1 Ship Identification Information
Items Information Remarks
Ship’s Name
IMO ID

4.1.2 Ship Specification Information


Items Specifications Remarks
Rudder number Single
Engine type Diesel
Engine number 1
Shaft number 1
Propeller Type FPP
Bow thruster ---
Stern thruster ---

4.1.3 Other Information (for arrangement for installation designing)


Items Information Remarks
Ship Type VCM Gas Carrier 3500m3 LPG
Classification NK-M0
Flag Singapore
Emergency AC Distributor AC220V
RCU Installed Location RCU: Recording Control Unit
4.2 LIST OF EQUIPMENT AND CONNECTION INTERFACE

4.2.1 Connection Interface for IEC61162 (connect to the NDV-1800 RCU)

Port Sentence
Equipment Name Manufacturer Model Serial No. Data description Source Device
No. Format
1 DGPS JRC JLR-7700MKII Date and Time ZDA*
Ship’s position GGA*
Local geodetic datum DTM*
2 Not connected ----- ----- ----- ----- ----- -----
3 Doppler Speed Log JRC JLN-205 Ground / Water speed VBW*
4 Gyro Compass TOKYO KEIKI TG-8000 Ship’s Heading (Gyro: true) HDT*
5 Auto-pilot TOKYO KEIKI Rudder order, manual HTD*
Heading / Track control setting HTD*
Rudder response, Automatic via
HTD*
auto-navigation system (if fitted)
Rudder response, manual RSA*
6 Not connected ----- ----- ----- ----- ----- -----
7 Echo Sounder JRC JFE-680 Depth DPT*
8 Anemometer NEI Wind direction MWV*
Wind speed
Telegraph demand position
9 Engine Telegraph NABTESCO MT-800III ETL**
Control place
10 M/E Remote NABTESCO M-800III Engine order PRC**
Control System Engine response RPM*
M/E Auto shut down & Manual
ALA**
shut down
M/E Auto slow down ALA**
11 Not connected ----- ----- ----- ----- ----- -----
12 Not connected ----- ----- ----- ----- ----- -----
13 Not connected ----- ----- ----- ----- ----- -----
14 Not connected ----- ----- ----- ----- ----- -----
15 Not connected ----- ----- ----- ----- ----- -----
ALA**
Contact alarms
Digital Signal WAT**
16 JRC NCT-72 (See 4.2.2 Connection Interface
Converter EVE**
for NCT-72)
FIR**

* Note-1: These characters show the sentence headers defined in the IEC61162-1.
** Note-2: These characters show the sentence headers defined in the IEC PAS61162-102 supplementary to the IEC61162-1.
*** Note-3: These characters show the sentence headers defined in the IEC PAS61162-101 supplementary to the IEC61162-2.
4.2.2 Connection Interface for Digital Signal (connect to the NCT-72 DSC)

CH Output
Equipment Name Manufacturer Model Signal description Signal Specification Source Device
No. Sentence
1 Steering Gear UZUSHIO No.1 S/G: Run Normal Open (Dry contact) ALA No.1 Steer Gear
2 No.1 S/G: No-volt Normal Close (Dry contact) ALA
3 No.1 S/G: Overload Normal Close (Dry contact) ALA
4 No.1 S/G: Phase failure Normal Close (Dry contact) ALA
5 No.1 S/G: Hyd. Oil Low level Normal Close (Dry contact) ALA
6 No.2 S/G: Run Normal Open (Dry contact) ALA No.2 Steer Gear
7 No.2 S/G: No-volt Normal Close (Dry contact) ALA
8 No.2 S/G: Overload Normal Close (Dry contact) ALA
9 No.2 S/G: Phase failure Normal Close (Dry contact) ALA
10 No.2 S/G: Hyd. Oil Low level Normal Close (Dry contact) ALA
11 E.C.C. UZUSHIO M/E Abnormal Normal Close (Dry contact) ALA via JB
12 G/E Abnormal Normal Close (Dry contact) ALA
13 Miscellaneous abnormal Normal Close (Dry contact) ALA
14 Bilge abnormal Normal Close (Dry contact) WAT
15 M/E Starting air LP Normal Close (Dry contact) ALA
16 M/E Remo-con abnormal Normal Close (Dry contact) ALA
17 M/E Source failure Normal Close (Dry contact) ALA
18 M/E Trip Normal Close (Dry contact) ALA
19 M/E Slow down / Request Normal Close (Dry contact) ALA
20 Auto-pilot TOKYO KEIKI No.1 Auto-pilot power fail Normal Close (Dry contact) ALA
21 No.2 Auto-pilot power fail Normal Close (Dry contact) ALA
22 Non follow up order -PORT Normal Open (Dry contact) EVE
23 Non follow up order -STBD Normal Open (Dry contact) EVE
24 Cargo System IZUMI Cargo TK Press Abn. Normal Close (Dry contact) ALA
25 Monitor Panel Cargo TK Temp Abn. Normal Close (Dry contact) ALA
26 Fire Alarm System NOHMI BOSAI Engine part fire Normal Close (Dry contact) FIR
27 Deck part fire Normal Close (Dry contact) FIR
28 Trouble alarm Normal Close (Dry contact) ALA
29 Main source failure Normal Close (Dry contact) ALA
Comb. Gas Alarm
30 TOKA SEIKI Comb. gas abnormal Normal Close (Dry contact) ALA
System
General Alarm
31 SANSHIN General alarm Normal Open (Dry contact) ALA
System
32 (Not connected) ----- ----- ----- ----- ----- -----
33 (Not connected) ----- ----- ----- ----- ----- -----
34 (Not connected) ----- ----- ----- ----- ----- -----
35 (Not connected) ----- ----- ----- ----- ----- -----
36 (Not connected) ----- ----- ----- ----- ----- -----
37 (Not connected) ----- ----- ----- ----- ----- -----
38 (Not connected) ----- ----- ----- ----- ----- -----
39 (Not connected) ----- ----- ----- ----- ----- -----
40 (Not connected) ----- ----- ----- ----- ----- -----
41 (Not connected) ----- ----- ----- ----- ----- -----
42 (Not connected) ----- ----- ----- ----- ----- -----
43 (Not connected) ----- ----- ----- ----- ----- -----
44 (Not connected) ----- ----- ----- ----- ----- -----
45 (Not connected) ----- ----- ----- ----- ----- -----
46 (Not connected) ----- ----- ----- ----- ----- -----
47 (Not connected) ----- ----- ----- ----- ----- -----
48 (Not connected) ----- ----- ----- ----- ----- -----
49 (Not connected) ----- ----- ----- ----- ----- -----
50 (Not connected) ----- ----- ----- ----- ----- -----
51 (Not connected) ----- ----- ----- ----- ----- -----
52 (Not connected) ----- ----- ----- ----- ----- -----
53 (Not connected) ----- ----- ----- ----- ----- -----
54 (Not connected) ----- ----- ----- ----- ----- -----
55 (Not connected) ----- ----- ----- ----- ----- -----
56 (Not connected) ----- ----- ----- ----- ----- -----
57 (Not connected) ----- ----- ----- ----- ----- -----
58 (Not connected) ----- ----- ----- ----- ----- -----
59 (Not connected) ----- ----- ----- ----- ----- -----
60 (Not connected) ----- ----- ----- ----- ----- -----
61 (Not connected) ----- ----- ----- ----- ----- -----
62 (Not connected) ----- ----- ----- ----- ----- -----
63 (Not connected) ----- ----- ----- ----- ----- -----
64 (Not connected) ----- ----- ----- ----- ----- -----
4.3 LIST OF AUDIO SIGNAL EQUIPMENT
4.3.1 Bridge Audio

Mic
Microphone Location Remarks
No.
1 Indoor type
2 (Not connected) -----
3 (Not connected) -----
4 Indoor type
5 (Not connected) -----
6 (Not connected) -----
7 Indoor type
8 (Not connected) -----
9 (Not connected) -----

4.3.2 Communication Audio

VHF
Equipment Name Manufacturer Model Serial No. Location Specification Remarks
No.
1 VHF Radio JRC JHS-770S 600-ohm 0-dBm
2 VHF Radio JRC JHS-770S 600-ohm 0-dBm
3 (Not connected) ----- ----- ----- ----- ----- -----
4.4 LIST OF VIDEO SIGNAL EQUIPMENT

Equipment Name Manufacturer Model Serial No. Specification Remarks


RGB/Hs/Vs
1280 x 1024 pixels
Non-interlace, Color
X-Band RADAR JRC JMA-7122-9XA Vs: 60Hz/TTL/Negative
Hs: 48.36kHz/TTL/Negative
RGB: 65MHz/0.7Vp-p/Positive/
75-ohm
External deck above bridge Microphones
(Compass Dk) NVT-161 VHF Audio
Protective Mic 1-3 Mic 4-6 Mic 7-9
Capsule Mic Group1 Mic Group2 Mic Group3
NDH-316A X-Ban RADAR
JMA-7122-9XA
POWER LAN
(JRC) Wheelhouse
JRC supply 3m JRC supply 3m
(attached to capsule) (attached to capsule) X-Band
Operation
RADAR
[TB1201] [TB1201] Panel Unit
System
Connection Box
NQE-3163 NCG-169
[TB1101]

VHF Telephone No.1


VHF Telephone No.2
[TB1201] [TB1201]

Mic-1
Mic-4
Mic-7

R
G
B
H synch
V synch
JRC supply :
*DPYCYS-1.5 H-7ZCAF0200
DC24V Ethernet cable 10m
(Shield Twist-Pair
cable with waterproof)
(Outer diameter: 14.9mm)

* TTYCS-1
* TTYCS-1
*TTYCS-1Q

*5C-2V-C
*5C-2V-C
*5C-2V-C
*5C-2V-C
*5C-2V-C
*TTYCS-1Q
*TTYCS-1Q

*TTYCS-1Q
[TB406] [J503] DATA [TB102] [R] [B] [VS] [R] [B] [VS] [TB901] [TB903] [TB905] [TB907] [TB909] [TB910] [TB912] [TB403] [J703] [J702]
[G] [HS] [G] [HS] [TB902] [TB904] [TB906] [TB908] [TB911]
CAPSULE VDR-LAN AC OUT Operation Panel JRC-LAN EXT-
RGB1 IN RGB2 IN Bridge Audio in VHF Audio in
Unit LAN

Recording Control Unit: NDV-1800


[TB401] [TB402] [TB404] [TB405]
[TB406]
[ch2] [ch4] [ch6] [ch8] [ch10] [ch12] [ch14] [ch16] [ch18] [ch20] [ch22] [ch24] [ch26] [ch28] [ch30] [ch32] Dry Contact out
[ch1] [ch3] [ch5] [ch7] [ch9] [ch11] [ch13] [ch15] [ch17] [ch19] [ch21] [ch23] [ch25] [ch27] [ch29] [ch31] ERROR ALARM [TB101] E

*1t x 25

* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1Q
To Digital Signal Converter
NCT-72: [TB1]
*DPYC-1.5 AC220V 60Hz 1 phase
[TB101]
*DPYC-1.5

Digital Signal Converter:

(NEI)

DGPS
NCT-72
AC220V 60Hz 1 phase

Auto-pilot
Anemometer

Echo Sounder

Gyro Compass
(JRC: JFE-680)

(JRC: JLN-205)
Engine Telegraph

(TOKYO KEIKI)
[ch1-10] [ch11-19] [ch20-23] [ch24-25] [ch26-29] [ch30] [ch31] E [TB1]

Doppler Speed Log


. AC Distributor

(JRC: JLR-7700MKII)
(NABTESCO: M-800III)
*0.5t x 25

(NABTESCO: MT-800III)

(TOKYO KEIKI: TG-8000)


M/E Remote Control System
* MPYC-2
* MPYC-2

* MPYC-7
* MPYC-4

* MPYC-19
* MPYC-12
* MPYC-12

Emergency AC Power Switchboard


Panel

[Emergency Generator Room]


System

(IZUMI)

Auto-pilot
(SANSHIN)

(UZUSHIO)
(UZUSHIO)

Steering Gear
E.C.C. (via JB)
(TOKA SEIKI)

*: Yard supply cables


(TOKYO KEIKI)
Comb. Gas Alarm

(NOHMI BOSAI)
Fire Alarm System
General Alarm System

Cargo System Monitor

JCY-1800 VOYAGE DATA RECORDER: CONNECTION DIAGRAM


CONNECTION BOX:
NQE-3163 / TB1201
OPERATION PANEL UNIT:
NCG-169 / TB1101
TB1 TB1

+12V
GND
T/R+
T/R-
4 5 6 7 8 1 2 3 1 2 3 4

1 2 3 4

TXP
TXN
RXP
RXN
2: GND
1: +24V

(10m)
cable with waterproof
*TTYCS-1Q

*DPYCYS-1.5

Ethernet shield twist pair


JRC supply: H-7ZCAF0200
CABLE CLAMP
CABLE CLAMP
Shield wire
Shield wire

2 3

J503 J703 J702


1 2 1 2 3 1 2 3 7 8 9 10 11 12 TB403 1 2 3 4
VDR-LAN TB406 JRC-LAN EXT-LAN

A
B
A
B

C
C

24V
PI1-
PI2-
PI3-
T/R-

PI1+
PI2+
PI3+
T/R+

GND
GND
+12V

CAPSULE ERROR ALARM SELECT

CDJ-2304: MAIN CONTROL BOARD (MCB) CQD-2040: MOTHER BOARD CDK-287: REMOTE MAINTENANCE BOARD (RMB)

RECORDING CONTROL UNIT: NDV-1800

*:yard supply cables

RECORDING CONTROL UNIT (NDV-1800): INTERCONNECTION WIRING (1/4)


No.4 Microphone Unit:
NVT-161
TB1
MIC SPKR
+ - s + - JHS-770S
1 2 3 4 5 VHF Telephone
No.1

JMA-7122-9XA
(JRC)

JHS-770S

No.1 Microphone Unit:


NVT-161
No.7 Microphone Unit:
NVT-161
X-Band RADAR Display
VHF Telephone
RGB Video output TB1 TB1 No.2
R G B VS MIC SPKR MIC SPKR
HS
+ - s + - + - s + -
1 2 3 4 5 1 2 3 4 5

*5C-2V-C
*5C-2V-C
*5C-2V-C
*5C-2V-C
*5C-2V-C
* TTYCS-1
* TTYCS-1

BNC Connector
JRC supply: BNCP-5
* TTYCS-1Q
* TTYCS-1Q
* TTYCS-1Q

R G B HS VS R G B HS VS

RADAR CH1 RADAR CH2


1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 1 2 3 1 2 3

-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
-
-
-

+
+
+

SG
SG
SG
SG
SG
SG
SG
SG
SG
FG
FG
FG

MIC1 SPK1 MIC2 SPK2 MIC3 SPK3 MIC4 SPK4 MIC5 SPK5 MIC6 SPK6 MIC7 SPK7 MIC8 SPK8 MIC9 SPK9
TB901 TB902 TB903 TB904 TB905 TB906 TB907 TB908 TB909 TB910 TB911 TB912
MIC-1 MIC-2 MIC-3 MIC-4 MIC-5 MIC-6 MIC-7 MIC-8 MIC-9 VHF-1 VHF-2 VHF-3
CQD-2041: AUDIO INTERFACE BOARD

AC OUT AC IN

RECORDING CONTROL UNIT: NDV-1800 E


TB102 U V E TB101 U V E

3 *1t x 25
1
2
* DPYC-1.5

- NOTE - EMERGENCY
The number seal is stuck on each microphone. AC POWER
This number means the position of the microphone recorded by VDR. SWITCHBOARD
Please attach a microphone according to the number of this drawing for installation. (AC Distributor)
AC220V 60Hz

*:yard supply cables

RECORDING CONTROL UNIT (NDV-1800): INTERCONNECTION WIRING (2/4)


Gyro Compass Anemometer M/E Remote
Control System

DIGITAL SIGNAL CONVERTER:


NCT-72
CONTROL BOARD / CDJ-2333
(No.1-5)
TG-8000
(TOKYO KEIKI) (NEI) M-800III
(NABTESCO)

TX+
TX-
RX+
RX-
1 2 4 5
DGPS Doppler Speed Auto-pilot Echo Sounder Engine
Log Telegraph
JLR-7700MKII JFE-680
(JRC) JLN-205 (TOKYO KEIKI) (JRC) MT-800III 16
(JRC) (NABTESCO) 17 18 19

* TTYCS-1

* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1
* TTYCS-1

* TTYCS-1
* TTYCS-1Q

CABLE CLAMP
CABLE CLAMP
CABLE CLAMP
CABLE CLAMP
CABLE CLAMP
CABLE CLAMP
CABLE CLAMP
CABLE CLAMP
CABLE CLAMP

Shield wire Shield wire Shield wire Shield wire Shield wire Shield wire Shield wire Shield wire Shield wire

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
TB401 TB402
TX-
TX-
TX-
TX-

RX-
RX-
RX-
RX-

RX-
RX-
RX-
RX-
RX-
RX-
RX-
RX-
RX-
RX-
RX-
RX-

TX+
TX+
TX+
TX+

RX+

RX+
RX+
RX+

RX+
RX+
RX+
RX+
RX+
RX+
RX+
RX+
RX+
RX+
RX+
RX+

GND
GND
GND
GND

CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16

CQD-2040: MOTHER BOARD

RECORDING CONTROL UNIT: NDV-1800

*:yard supply cable

RECORDING CONTROL UNIT (NDV-1800): INTERCONNECTION WIRING (3/4)


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
TB404 TB404

RX-
RX-
RX-
RX-
RX-
RX-
RX-
RX-

RX-
RX-
RX-
RX-
RX-
RX-
RX-
RX-

RX+
RX+

RX+
RX+
RX+
RX+
RX+
RX+

RX+
RX+
RX+
RX+
RX+
RX+
RX+
RX+

CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 CH25 CH26 CH27 CH28 CH29 CH30 CH31 CH32

JRC Remote Meintenance Port

CQD-2040: MOTHER BOARD

RECORDING CONTROL UNIT: NDV-1800

*:yard supply cable

RECORDING CONTROL UNIT (NDV-1800): INTERCONNECTION WIRING (4/4)


PROTECTIVE CAPSULE UNIT
NDH-316A

(3m)
(3m)

Red Cable
for Ethernet
Black Cable

for Power Supply


Acceptable Cable Diameter Acceptable Cable Diameter

Cable attached with HVR


Cable attached with HVR
5.0mm - 11.0mm 5.0mm - 11.0mm

CONNECTION BOX
NQE-3163

COLOR
red
black
white/green
green
white/orange
orange

red
black
white/green
green
white/orange
orange
TX-
RX-

TX+
RX+

SHIELD
SHIELD

DC GND
+24V DC

TB1201
1 2 3 4 5 6 7 8

1 2 1 2 3 6
1
2
3
4
5
6
7
8

POWER ETHERNET

Acceptable Cable Diameter Acceptable Cable Diameter


10.0mm - 20.0mm 10.0mm - 20.0mm

(10m)

* DPYCYS-1.5
with waterproof

JRC supply: H-7ZCAF0200


Ethernet shield twist pair cable

CABLE CLAMP
RJ-45 Connecting table
PIN No. Signal Cable color
CQD-2040 CDJ-2304 1 TXP white / green
TB406 1 2 J503 2 TXN green
3 RXP white / orange
INSIDE of NDV-1800

4 - blue

24V
GND 5 - white/blue
6 RXN orange
7 - white/brown *:yard supply cable
CAPSULE
8 - brown

CONNECTION BOX (NQE-3163): INTERCONNECTION WIRING


OPERATION PANEL UNIT
NCG-169

+12V
GND
T/R+
T/R-
TB1101 1 2 3 4

1 2 3 4

* TTYCS-1Q

CQD-
2040/TB403
1 2 3 4
INSIDE of NDV-1800

T/R-

T/R+

GND

+12V

*:yard supply cable


Operation Panel Unit

OPERATION PANEL UNIT (NCG-169): INTERCONNECTION WIRING


MICROPHONE ALLOCATION
MICROPHONE CONNCTION of NDV-1800
LOCATION
No. connector
MICROPHONE UNIT
NVT-161 1 J901
2 (None Connected) J902

MIC SPKR 3 (None Connected) J903


TB1 4 J904
+ - s + -
1 2 3 4 5 5 (None Connected) J905
6 (None Connected) J906
7 J907
3
8 (None Connected) J908

1 2 4 5 9 (None Connected) J909

*TTYCS-1Q
1 2 3 4 5

-
-

+
+
S
TB901 - TB909
MIC
MIC SPK

INSIDE of NDV-1800
CQD-2041: AUDIO INTERFACE BOARD

*:yard supply cable

MICROPHONE UNIT (NVT-161) : INTERCONNECTION WIRING


VHF RADIO TELEPHONE
JHS-770S (JRC)
VHF RADIO TELEPHONE ALLOCATION
VHF TELEPHONE CONNCTION of NDV-1800
No. LOCATION
Connector

EXT SP 1 TB910
(600-ohm balance) 2 TB911
3 (None Connected) TB912

+
-
TB2 13 14 15

1 2

* TTYCS-1
1 2 3

-
TB910 - TB912

+
FG
VHF IN

INSIDE of NDV-1800
CQD-2041: AUDIO INTERFACE BOARD

*:yard supply cable

VHF RADIO TELEPHONE INTERCONNECTION WIRING


TB1

* MPYC-19
CH1

No.1 S/G: Run


1

CH1(+)
2

CH1(-)
CH2

No.1 S/G: No-volt


3

CH2(+)
4

CH2(-)
CH3

No.1 S/G: Overload


5

CH3(+)
6

CH3(-)
CH4

No.1 S/G: Phase failure


7

CH4(+)
8

CH4(-)
CH5

No.1 S/G: Hyd. Oil Low level


CH5(+)
CH5(-)
CQD-2081: JUNCTION BOARD
CH6

No.2 S/G: Run


CH6(+)
(UZUSHIO)
Steering Gear

CH6(-)
CH7

No.2 S/G: No-volt


CH7(+)
CH7(-)
CH8

No.2 S/G: Overload


DIGITAL SIGNAL CONVERTER: NCT-72

CH8(+)
note:

CH8(-)
CH9

No.2 S/G: Phase failure


CH9(+)
INPUT

CH9(-)
CH10

No.2 S/G: Hyd. Oil Low level


CH10(+)
CH10(-)
CH11

* MPYC-12 M/E Abnormal


CH11(+)
CH11(-)
CH12

G/E Abnormal
CH12(+)
CH12(-)
CH13

Miscellanious abnormal
CH13(+)
CH13(-)
CH14

Each CH's(-) terminal on Junction Board is common line. (Negative common) Bilge abnormal
CH14(+)
CH14(-)
CH15

M/E Starting air LP


CH15(+)
CH15(-)
CH16

M/E Remo-con abnormal


CH16(+)
E.C.C.
(UZUSHIO)

CH16(-)
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
TB2
CABLE CRAMP

Shield wire
CH17

M/E Source failure


CH17(+)
CH17(-)
CH18

M/E Trip
CH18(+)
CH18(-)
CH19

M/E Slow down / Request


CH19(+)
CH19(-)
CH20

* MPYC-7 No.1 Auto-pilot power fail


CH20(+)
CH20(-)
CH21

No.2 Auto-pilot power fail


CH21(+)
CH21(-)
CH22

Non follow up order -PORT


Auto-pilot

CH22(+)
(TOKYO KEIKI)

CH22(-)
CH23

Non follow up order -STBD


CH23(+)
CH23(-)
CH24

* MPYC-4 Cargo TK Press Abn.


CH24(+)
CH24(-)
CH25

Cargo TK Temp Abn.


(IZUMI)

CH25(+)

INPUT
Monitor Panel
Cargo System

CH25(-)
CH26

* MPYC-12 Engine part fire


CH26(+)
CH26(-)
CH27(+) CH27 Deck part fire
CH27(-)

CH28
Trouble alarm
CH28(+)
(NOHMI BOSAI)

32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
CH28(-)
Fire Alarm System

CH29
Main source failure

8
CH29(+)

TB1
CH29(-)

CH30
* MPYC-2 Comb. gas abnormal Comb. Gas

6
CH30(+) Alarm System
(TOKA SEIKI)

1
U
5
* DPYC-1.5 CH30(-)

CH31
* MPYC-2 General Alarm

2
V
General alarm

4
CH31(+) System

AC IN
(SANSHIN)

3
E
3
CH31(-)

AC POWER

AC220V 60Hz
EMERGENCY

SWITCHBORD
(AC Distributor)
2
CH32(+)

1
CH32(-)

E
CABLE CRAMP

Shield wire

*0.5t x 25

DIGITAL SIGNAL CONVERTER (NCT-72): INTERCONNECTION WIRING (1/2)


*:yard supply cable
TB3
1

CH33(+)
2

CH33(-)
3

CH34(+)
4

CH34(-)
5

CH35(+)
6

CH35(-)
7

CH36(+)
8

CH36(-)
CH37(+)
CH37(-)
CQD-2081: JUNCTION BOARD

CH38(+)
CH38(-)
CH39(+)
CH39(-)
DIGITAL SIGNAL CONVERTER: NCT-72

CH40(+)
CH40(-)
CH41(+)
INPUT

CH41(-)
CH42(+)
CH42(-)
CH43(+)
CH43(-)
CH44(+)
CH44(-)
CH45(+)
CH45(-)
CH46(+)
CH46(-)
CH47(+)
CH47(-)
CH48(+)
CH48(-)
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
TB4

CH49(+)
CH49(-)
CH50(+)
CH50(-)
CH51(+)
CH51(-)
CH52(+)
CH52(-)
CH53(+)
CH53(-)
CH54(+)
CH54(-)
CH55(+)
CH55(-)
CH56(+)
CH56(-)
CH57(+)

INPUT
CH57(-)
CH58(+)
CH58(-)
CH59(+)
CH59(-)
CH60(+)

32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
CH60(-)

8
CH61(+)

7
CH61(-)

6
CH62(+)

5
CH62(-)

4
CH63(+)

3
CH63(-)

2
CH64(+)

1
CH64(-)

1
TX+
RECORDING CONTROL UNIT:

1
RX+

2
TX- NDV-1800

16 17
TB402 / CH16 (No.16-19)

2
RX-

3
GND

CDJ-2333:
4
4
RX+ TX+

*:yard supply cable

DIGITAL SIGNAL CONVERTER (NCT-72): INTERCONNECTION WIRING (2/2)


* TTYCS-1Q

5
TB402 / CH16
RX- TX-

16 17 18 19

18 19
5

6
GND

CONTROL BOARD
CABLE CRAMP

Shield wire
DATA PROCESSOR UNIT (NDL-46)
Inmarsat-F
for Remote Maintenance
Uninterruptible Power Supply
Mother Board (MB) Main Control Board (MCB)
NBL-327 CQD-2040 CDJ-2304 Z102 JRC-LAN
Z201 7PCJD0216 7PCJD0213 7HRJD0002 HUB
7ZBJD0010
W111
3m LAN cable
Power Supply Board (PSB) (Accessory)
CBM-168
7EPJD0013 Maintenance PC

W103
7ZCJD0277
POWER
BATTERY
Audio Interface Board (AIB)
ABNORMAL CQD-2041
Z202 BATTERY
7PCJD0217
FS301 OPERATION
7ZBJD0010 J505
VHF x 3
5A FAN ALARM J601 (40) TB910 TB911 TB912 MIC max.9
W105
・Indoor type:NVT-161
7ZCJD0280
5A ・Waterproof type:NVT-162
Audio Recording Board (ARB) TB901 TB902 TB903
FS302 CHA-387 VHF max.3
S201 MIC x 9
7PCJD0214 TB904 TB905 TB906
7SAJD0001

TB907 TB908 TB909

J101 J106
Main RADAR
R,G,B,Vs,Hs
J102 J107

S202 J103 J108


7SCJD0002
Remote Maintenance Board (RMB)
J104 J109
CDK-287 Sub RADAR
7PCJD0215 R,G,B,Vs,Hs
J105 J110

AC IN AC OUT
J301 J302 Dry Contact I/F
(3) (2) ・Output port: 2CH
・Input Port: 3CH
UPS Chassis W201 W202
CWB-1385 7ZCJD0273 7ZCJD0274 J802
J201 J202
(3) (2)
W104 Frame Grabber Board (FGB) IEC61162-1 /2
AC OUTLET 7ZCJD0278 ・32CH
AC85~132V CKA-137
7PCJD0211 W106
or
AC170~265V 7ZCJD0281

RX1+ RX17+ +24V


POWER TERMINAL RX1- RX17- GND
RX2+ RX18+ ERR_A
POWER IN RX2- RX18- ERR_C
AC85~132V RX3+ RX19+ ERR_B W107
or RX3- RX19- ARM_A 7ZCJD0281
AC170~265V RX4+ RX20+ ARM_C
W101
W2 RX4- RX20- ARM_B
7ZCJD0275 RX5+ RX21+ PI1+ TB1201
TB101 RX5- RX21- PI1-
RX6+ RX22+ PI2+ Junction Box (JB)
RX6- RX22- PI2- NQE-3163
RX7+ RX23+ PI3+ 7ZZJD0050
POWER TERMINAL RX7- RX23- PI3-
W102 Capsule (HVR)
Switched POWER OUT RX8+ RX24+
for Option unit and FGB unit 7ZCJD0276 NDH-316A
RX8- RX24-
AC85~132V RX9+
or RX9- HEADING
AC170~265V RX10+ +12V T/R+ POWER SYSTEM DAU CH
RX10- GND T/R-
T/R+ +12V RECORDING
W3 RX11+
TB102 RX11- T/R- GND ALARM
RX12+ MODE
RX12- ACK DIMMER

RX13+ RX25+ PULS-


TB1003 PULS+ Option TB1101 ENT
RX13- RX25-
TX13+ RX26+ NSK Interface Board (NIB) 7JTJD0037 W1101 BUZZ CKK-935
W110 REF2
FUSE TX13- RX26- CHM-378 REF1 Heading data
7ZCJD0283 7ZCJD0285 7PCJD0220
BATTERY GND RX27+ 7PCJD0219 S3 Synchro signal
5A x 2 RX14+ RX27- TB1002
S2 Step signal
RX14- RX28+ S1
TX14+ RX28- Operation Panel Unit (OPU) OPU Chassis
Z101 TX14- RX29+ COM Speed log data NCG-169 CWB-1410
7ZBJD0006A GND RX29- S3
TB1001 S2
Pulse signal
Battery RX15+ RX30+
RX15- RX30- S1
24V 5Ah
TX15+ RX31+
TX15- RX31-
Thermo-Sensor GND RX32+
CHG-213 RX16+ RX32-
RX16-
7PCJD0221 W1201
TX16+
7ZCJD0282 TX16-
GND RCU Chassis
CWB-1378

NDV-1800 RECORDING CONTROL UNIT: SCHEMATIC DIAGRAM


HEADING
POWER ALARM DETAIL

RECORDING
MODE
ALARM 1
SYSTEM CODE
+12V
W1101 GND RCU
T/R +

J1101
7ZCJD0285
ACK DIM T/R -
4
ENT TB1101
7JTJD0037

BUZZ

OPB CCK-935

NCG-169 OPERATION PANEL UNIT: SCHEMATIC DIAGRAM


TB1
MIC CN1 MIC+
+ RED 1 TTYCS-1Q
1 MIC-
- BLUE MIC AMP Board 2
2 SHIELD
+ YELLOW MIC-P2(R1) 3 RCU
3 SP+
- WHITE 4
4 SP-
5
SPEAKER

TB1:WAGO 255 Series

NVT-161 MICROPHONE UNIT: SCHEMATIC DIAGRAM


TB1 TB2 TB3 TB4
1 CH01 CH09 32 CH17 CH25 1 CH33 CH41 32 CH49 CH57
CH02 CH10 CH18 CH26 CH34 CH42 CH50 CH58

CH03 CH11 CH19 CH27 CH35 CH43 CH51 CH59

Dry Contact in

J1
CH04 CH12 CH20 CH28 CH36 CH44 CH52 CH60

P51
CH05 CH13 CH21 CH29 CH37 CH45 CH53 CH61
x64ch
W102
CH06 CH14 CH22 CH30 CH38 CH46 CH54 CH62
7ZCJD0286
AC/DC Power Supply Unit CH07 CH15 CH23 CH31 CH39 CH47 CH55 CH63
AES30-12 CH08 CH16 CH24 CH32 CH40 CH48
32 1 32 CH56 CH64 1

J202
Dry Contact Input Board
P1
CQD-2081

J2

W101
CN1
7ZCJD0189A
POWER IN
AC85~132V or
AC170~265V J102

U
FUSE
AC Filter Board RCU

V
TB101 NMEA data output
CBJ-147 1 Tx+
Dry Contact Control Board Tx-

E
CDJ-2333 GND
Rx+
O I

SW
J104 5 Rx-

TB1
J103

NCT-72 DIGITAL SIGNAL CONVERTER (64CH): SCHEMATIC DIAGRAM


8. Outline Drawings
8.1. NDH-316A Protective Capsule Unit

VOYAGE DATA RECORDER TA RECORDER


DO NOT OPEN T OPEN
REPORT TO AUTHORITIES AUTHORITIES
8.2. NQE-3163 Connection Box
8.3. NDV-1800 Recording Control Unit
8.4. NCG-169 Operation Panel Unit

NCG-169 VDR OPERATION PANEL


8.5. NVT-161 Microphone Unit
8.6. NCT-72 Digital Signal Converter (64CH)
9. MECHANICAL INSTALLATION

9.1. Protective Capsule: NDH-316A

9.1.1. Selecting the Location


The Protective Capsule contains the final recording medium. If the capsule should sink into the sea, it
would be retrieved by ROV (Remote Operation Vehicle) or by divers.
To ensure its continuous normal operation and also to ease its recovery and maintenance, the capsule
needs to be mounted at a suitable location and in an appropriate way. It should be recommended that the
capsule be mounted at a place that satisfies the following conditions.

1) External open deck, e.g. compass deck


2) A place where the capsule can be appropriately grounded to the ship’s hull
3) A place where unobstructed open space can be secured in its vicinity
4) A place as close to the central line of the ship as possible
5) A place where a compass safety distance over 0.5m in radius can be secured
6) A place that allows easy recovery of the capsule, should the ship sink into the sea

9.1.2. Installing the Capsule

9.1.2.1. Mounting the Capsule

Mount the capsule with 12 mm steel bolts to the mounting bracket on the external deck. To secure the
grounding of the capsule, do not paint the contact surface of the mounting bracket.

VOYAGE DATA RECORDER


DO NOT OPEN
REPORT TO AUTHORITIES

FIG. 1: Mounting the Protective Capsule NDH-316A


9.1.2.2. Fastening the Capsule

Fasten the capsule with external tooth lock washers to the mounting bracket on the external deck.
Then, apply a waterproof treatment of RTV (Room Temperature Vulcanizing) sealing material to
secure its grounding to the ship’s hull .

VOYAGE DATA RECORDER


DO NOT OPEN
REPORT TO AUTHORITIES

FIG. 2: Grounding to the Hull

The procedures for fastening the Capsule are:

i. Remove the painting around the three holes in the mounting brackets of the Protective Capsule
(NDH-316A).
ii. Place an external tooth lock washer on each of the three holes in the mounting brackets.
iii. Apply RTV (Room Temperature Vulcanizing) sealants around the mounting holes.
iv. Place the Protective Capsule (NDH-316A) on the mounting brackets. Adjust the capsule’s
position so that its three holes coincide with those of the mounting brackets.
v. Put steel bolts in the holes.
vi. Fasten the bolts with nuts.
9.1.2.3. Vicinity clearance of the Capsule: NDH-316A
To ease the maintenance of the Protective Capsule and its recovery in the event of any sea accident,
make sure that its vicinity is clear and free from obstacles.

VO YAG E DATA R ECO RDER


DO NOT OPE N
REPO RT TO A UTHORITIES

FIG. 3: Vicinity of the Capsule: NDH-316A


9.2. Connection Box: NQE-3163

9.2.1. Selecting the Location


The Connection Box connects the Protective Capsule and the Recording Control Unit with a data line
and a power supply line.

It should be recommended that its location should be selected to meet the following conditions.

1) The location needs to be within 1.5m from the Protective Capsule. (The cable attached with the
Protective Capsule is 3.0m in length.)
2) The location needs to be free from excessive vibrations.

9.2.2. Mounting the Connection Box

Fix the Connection Box to handrail or the support pole provided for this box.
The length between the Protective Capsule and the Connection Box should be within 1.5m.

FIG. 4: Mounting the Connection Box


9.2.3. Mounting the Connection Box

AUT HORITIES
TA RECORDER
T OPEN
REPORT TO AUTHOR ITIES
VOYAGE DAT A RECORDER
DO NOT OPEN

FIG. 5: Location for Mounting the Protective Capsule and the Connection Box
9.3. Recording Control Unit: NDV-1800

9.3.1. Selecting the Location

It should be recommended that the location for mounting the Recording Control Unit (NDV-1800) be
selected to meet the following conditions.
It should be recommended that the Recording Control Unit to be mounted in the wheelhouse.
The international standards require the Operation Panel Unit (NCG-169) to be mounted in the
wheelhouse.

1) The length of the cable between the Recording Control Unit and the Protective Capsule
(NDH-316A) should not exceed 30m.
2) The lengths of cables connected to the units installed in the wheelhouse should be as short as
possible.
3) The Recording Control Unit should be protected from bad weathers, and the temperature
around it should be kept at a comfortable level.
4) The Recording Control Unit should be free from excessive vibrations.
5) The Recording Control Unit should be within a compass safety distance of 1.2m.
6) The Recording Control Unit should be distant enough from electric apparatuses such as a
RADAR and radio communication devices that emit excessive electromagnetic field.
7) The maintenance operations such as backing up the data and replacing the battery of the
power supply unit should be easy enough.

9.3.2. Fastening the Recording Control Unit

9.3.2.1. Connecting Cables

1) Wiring hole:
The Recording Control Unit is connected with cables from the Protective Capsule, the Operation
Panel Unit, the Radar video, the Microphone Units, the Sensor signal (IEC61162-1/2) and so on.
The Recording Control Unit therefore has holes in its bottom for these cables to come through.

2) Grounding terminal:
To ensure continuous and stable operations, the Recording Control Unit needs to be grounded to
the ship’s hull

9.3.2.2. Vicinity Clearance of the Recording Control Unit

The Recording Control Unit has a front door. To allow the door to open easily at anytime, the area
within 0.43m of the front door should be kept obstacle-free.

9.3.2.3. Fastening the Recording Control Unit

Fasten the Recording Control Unit onto a bulkhead with four M8 steel bolts (φ10mm). The
bulkhead has to sustain the weight of 23kg of the Recording Control Unit.
FIG. 6: Mounting Outline and Vicinity Clearance of the Recording Control Unit
NDV-1800
9.4. Operation Panel Unit: NCG-169

9.4.1. Selecting the Location

The Operation Panel Unit should be installed in the bridge console panel or a bulkhead in the
wheelhouse.

9.4.1.1. Recommended Location

The following is the recommended location for mounting the Operation Panel Unit. It should be in
the wheelhouse.

1) The bridge console panel


2) The panel in the back of the wheelhouse

9.4.1.2. Note on selection

Consider the followings when selecting a location for mounting the Operation Panel Unit.

1) In the event of an alarm going off, one, while piloting the ship, should hear the alarm tone
sounding and see the alarm lamp lighting.
2) The Operation Panel Unit should be away from electric apparatuses such as the RADAR
transceiver, radio communication equipment, and so on that may emit an excessive
electromagnetic field.
3) The Operation Panel Unit should be free from excessive vibrations.
4) The Operation Panel Unit should be within a compass safety distance of 0.1m.

9.4.2. Fastening the Operation Panel Unit

The Operation Panel Unit can be fastened on or in the bulkhead or console panel. When it is placed in
the bulkhead or the console panel, the surface of the panel needs to be cut out in the shape shown in the
Figure in the next page. When it is fastened on the bulkhead or the console panel, remove its flange. It
has 2 wiring holes in the bottom and the back for cables to come in through.
NCG-169 VDR OPERATION PANEL

FIG. 7: Mounting Outline and Vicinity Clearance of the External Alarm Unit
(Built-in Type)

NC G - 1 6 9 VD R O P E RA T I O N P AN E L

FIG. 8: Mounting Outline and Vicinity Clearance of the External Alarm Unit
(Exposed Type)
9.5. Microphone Unit: NVT-161

9.5.1. Selecting the Location

The Microphone Unit collects conversations in the bridge, other voices through the public addressor and
the intercom, and alarms buzzers of the group panel installed in the bridge. The locations of the
microphones should be carefully selected so that they can record vital voice communications.

9.5.1.1. Recommended Location

Although the number of microphones needed depends on the bridge layout, in most cases three
microphones will do. The recommended locations for mounting microphones are:

1) The overhead panel or the ceiling above the main conning station.
2) The overhead panel or the ceiling above the main route planning station i.e., the chart table.
3) The overhead panel or the ceiling in the vicinity of the radio transceiver.

9.5.1.2. Notes on selection

Consider the followings when selecting a location for mounting a Microphone Unit.
Microphones can collect conversations within a radius of 2.5m. Any obstacles or sources of noise
(60dB or more) should be kept out of this range.

1) The microphone unit should be away from any ventilator or draft.


2) The microphone unit should be away from electric apparatuses such as the RADAR, radio
communication equipment, and so on that may emit an excessive electromagnetic field.
3) The microphone unit should not be exposed to excessive vibration.
4) The microphone unit should be in a compass safety distance of 0.5m.

9.5.2. Fastening a Microphone Unit

A Microphone Unit can be mounted in or on the ceiling, a bulkhead, or a console panel. When mounting
it in a console panel, cut out the panel surface in the shape as shown in the figure in the next page.
Or when mounting it on the surface, remove the flange from the Microphone Unit.
Any Microphone Unit has 2 wiring holes.
It has a label for the unit number on it. Confirm the location of the label and make sure that the unit
number on the label is equal to what is written in the instruction drawing.
FIG. 9: Mounting Outline and Installation Clearance of the Microphone Unit
(Built-in Type)

FIG. 10: Mounting Outline and Installation Clearance of the Microphone Unit
(Exposed Type)
9.6. Digital Signal Converter: NCT-72 - 64ch - (VDR Option)

9.6.1. Selecting the Location

The location of a Digital Signal Converter should meet the following conditions.
1) The length of the cable to each sensor should be as sort as possible.
2) The Digital Signal Converter should be protected from bad weathers, and the temperature around it
can be kept at an appropriate level.
3) The Digital Signal Converter should be free from excessive vibrations.
4) The compass safety distance of 0.2m can be secured.
5) The Digital Signal Converter should be away from electric apparatuses such as the RADAR, radio
communication equipment, and so on that may emit an excessive electromagnetic field.
6) The maintenance and inspections should be easy enough.
7) The grounding wire to the ship’s hull should be as short as possible.

9.6.2. Fastening the Digital Signal Converter

9.6.2.1. Connecting Cables

1) Wiring hole:
Any Digital Signal Converter is connected with cables from the Recording Control Unit and various
sensors. It therefore has wiring holes in its back and bottom for these cables to come in through.
2) Grounding terminal:
To ensure continuous and stable operations, any Digital Signal Converter needs to be grounded
appropriately to the ship’s hull.

9.6.2.2. Vicinity Clearance of a Digital Signal Converter

Any Digital Signal Converter has a cover on top. To allow the cover to open easily at anytime for
maintenance and inspections, the area within 0.43m of the top cover should be kept obstacle-free.

9.6.2.3. Fastening a Digital Signal Converter

Fasten a Digital Signal Converter onto a bulkhead with four M6 steel bolts (φ7.5mm). The bulkhead
has to sustain the weight of 5.0kg of the Digital Signal Converter .
FIG. 11: Mounting Outline and Vicinity Clearance of a Digital Signal Converter
10. Spare Parts List
10.1. NDV-1800 / 1850 Recording Control Unit
SETS PER
SHIP NO. SPARE PARTS LIST FOR USE
VESSEL
NDV-1800 / 1850
RECORDING CONTROL UNIT

JCY-1800 / 1850
VDR / S-VDR

QUANTITY REMARKS
ITEM OUTLINE WORKING DESCRIPTION SUB
NAME OF PART
NO. (DIMENSION IN M/M) PER PER SPARE MARK OF
JRC CODE NO.
SET VESS BOX NO.
30
MF60NR 250V 5

6.4
1 FUSE 4 - 8
5ZFGD00014

CNT
60

2 FAN 160 2 - 2 7ZBJD0010

15 60

MFR’S NAME JAPAN RADIO CO. , LTD. DWG. NO 7ZXJD0080

Note: Spare Part (description or JRC code number) may be replaced with compatible part.
予備品(型名・コード)は、予告無く互換品に変更する事がございます。
10.2. NCT-72 / 63 Digital Signal Converter
SETS PER
SHIP NO. SPARE PARTS LIST FOR USE
VESSEL
NCT-72 / 63
DIGITAL SIGNAL CONVERTER

JCY-1800
VOYAGE DATA RECORDER

ITEM NAME OF PART OUTLINE QUANTITY REMARKS


NO. (DIMENSION IN M/M) WORKING SPARE DESCRIPTION SUB
PER PER JRC CODE NO. MARK OF
SET VESS BOX NO.
30
MF60NR 250V 3.15

6.4
1 FUSE 1 - 2
5ZFGD00012

MFR’S NAME JAPAN RADIO CO. , LTD. DWG. NO 7ZXJD0092

Note: Spare Part (description or JRC code number) may be replaced with compatible part.
予備品(型名・コード)は、予告無く互換品に変更する事がございます。
DATA
検査成績書
INSPECTION DATA
1/4

Messrs. 殿

検 査 成 績 書
INSPECTION DATA
航海データ記録装置
VOYAGE DATA RECORDER

JCY-1800
JCY-1800

製造番号
Serial No. MB37086
検 査 日
Date of inspection 10 Feb 2010

課 長
Approved by
検 査 員
Inspected by
検査担当部門 海上機器品質保証部航法機器品質保証グループ
Section Navigation Group
Quality Assurance Department / Marine Electronics

2JC-2384
2/4

製造番号
Serial No.:MB37086

指 定 照 合 判 定
1 Verification to specification Judgment Good

機 構 検 査 判 定
2 Structural inspection Judgment Good

性 能 検 査 判 定
3 Performance inspection Judgment Good

総 合 動 作 試 験 試験電圧
AC100V
3.1 Overall operation test Examination Voltage
項 目 仕様・規格 結 果
Items Specifications Result
3.1.1 絶縁抵抗 AC ラインと FG の間の絶縁が 100MΩ以上あること。
Insulation resistance Between AC line and Frame-ground, exceed over Good
100M-ohm.
3.1.2 耐電圧 AC200V 系統 →E: AC1500V 1 分間
Good
Withstand voltage 200VAC system →E:1500VAC for 1minutes
3.1.3 消費電力 50VA 以下であること。
Power consumption To be less than 50VA Good
JCY-1800

3.1.4 動作試験 起動後、RCU 内部の MCB ボードの“REC“及び


Operation test “CARD”ランプが点灯し、データ記録が自動的に開始
されること。
Good
On completing the initial test, data recording should
be started automatically with lighting the “CARD”
and “REC” lamp on the MCB Board of the RCU.
主電源を切断した後、バッテリモードへ自動的に切り
換わること。
Good
On turn off the main AC power, the system should be
changed automatically to battery supply mode.
主電源を復旧した後、商用電源モードへ自動的に切り
換わること。
On turn on the main AC power again, the system Good
should be changed automatically to normal power
supply mode.
3/4

製造番号
Serial No.:MB37086

電 気 的 特 性 試 験
3.2 Electrical characteristics test
項 目 仕様・規格 結 果
Items Specifications Result
3.2.1 システム構成 システムが、出荷構成に適応して構築されているこ
System configuration と。
Units comprising the system should be set with the Good
initial data in according with system configuration.

カプセル 接続設定されていること。
Protective capsule To be set with connectable information.
Good
記録制御機 設定内容を最終図面と照合し、適当であること。
Recording control To be set with correct information in according with Good
unit the final drawings.
3.2.2 インターフェース データおよび信号の入力インターフェースが、下記の
Data Interface とおり、適正に動作していること。
The interface units acquiring data and/or signal Good
should be functioned as follows:

記録制御機 設定されたヘッダを持つセンテンスを接続し、エラー
Recording control が発生しないこと。
unit The self-check results of NMEA sentence reception, which
Good
is designated with connection setting, should not be fault.
3.2.3 マイクロフォン機能 マイクロフォンの自己診断テストの結果、エラーが発
JCY-1800

Microphone 生しないこと。
functionality The self-check results of microphone functionality, Good
which is designated with connection setting, should
not be fault.
3.2.4 時間管理 システムクロックが、世界時(UTC)で動作しているこ
Time stamp と。
management The system clock managed in data recording control Good
should be set with Universal Time coordinated
(UTC).
4/4

製造番号
Serial No.:MB37086

項 目 仕様・規格 結 果
Items Specifications Result
3.2.5 データ記録 記録データのバックアップを行い、再生装置で記録デ
Data recording ータを確認できること。
functionality The recording data should be checked on a playback
system for inspection after saving the recording data Good
to PC CARD following approx. 10 minutes recording.

設定データ 設定データが、設定どおり確認できること。
Configuration data To be checked in accordance with configuration Good
data recorded in initial setting.
IEC61162 データ 取得されるべきデータが、世界時のタイムスタンプ
IEC61162 sentence が付加されて、取得時間順に記録されていること。
data To be checked that the acquired data, which are Good
designated on the interface setting, are recorded
chronologically, attached with time stamp by UTC.
音声データ 接続されるマイクチャンネルのオーディオ信号を
Voice audio data 取得できていること。
To be checked that audio data acquired on each Good
microphones, which is designated to connect are
played back.
VHF 通信データ 接続される VHF チャンネルのオーディオ信号を取
VHF audio data 得できていること。
JCY-1800

To be checked that audio data acquired on each Good


input channel, which is designated to connect, are
played back.
レーダ画像データ 設定どおりの画像データが取得できていること。
RADAR Video image To be checked that video data acquired on input Good
data channel is played back.

バ ッ テ リ 状 態 の 確 認
3.3 Checking batteries condition
項 目 仕様・規格 結 果
Items Specifications Result
3.3.1 UPS バッテリ バッテリの有効期限が 3 年以上あること
UPS batteries To be checked that valid term of battery exceeds over Good
3 years.
3.3.2 カプセルビーコンバ バッテリの有効期限が 5 年以上あること
ッテリ To be checked that valid term of battery exceeds over
Battery for beacon 5 years.
Good
attached to capsule
使用計測器一覧表
Measuring Instruments for Inspection
型名
Model JCY-1800
オーダー
Order 2JC-2384
製造番号
Serial No. MB37086
台数
Q’ty 1
品 名 型 式 製造者名 管理番号 使用 有効期限
No.
Description Model No. Manufacturer Control No. Used Cal Due Date
デジタルマルチメーター
1 Digital Multi Meter
77 FLUKE 07-1-377 ○ Mar 2010

交流電圧電流計
2 AC Voltmeter/Ammeter
SPFB YOKOGAWA 04-5-037 ○ Jan 2011

絶縁抵抗計
3 Insulation Tester
PIT-5A TOA 94-0-036 ○ May 2010

歪率計
4 Distortion Meter/Oscillator
AH979G ShibaSoku 34-0-385 ○ Dec 2010

電圧電流発生器
5 Programmable DC 2553 YOKOGAWA 00-2-021 ○ Jun 2010
Voltage/Current Generator
検査用パソコン
6 Inspection PC
Optiplex GX280 DELL 18-63313 ○ -------

* 使用欄に使用した計測器には 〇印を記入すること
* Write down a 〇 mark in the measurement vessel used for the use column.
JCY-1800
VOYAGE DATA RECORDER
Conforms to IMO MSC.214(81)

INSTRUCTION
MANUAL

For further information,contact:

Not use the asbestos

URL http://www.jrc.co.jp
Marine Service Department
Telephone : +81-3-3492-1305
Facsimile : +81-3-3779-1420
e-mail : tmsc@jrc.co.jp
AMSTERDAM Branch
Telephone : +31-20-658-0750
Facsimile : +31-20-658-0755
e-mail : service@jrcams.nl
SEATTLE Branch
Telephone : +1-206-654-5644
Facsimile : +1-206-654-7030
e-mail : service@jrcamerica.com
CODE No.7ZPJD0385
No.7ZPJD0385B 01ETM ISO 9001, ISO 14001 Certified
MAY.. 2008 Edition 1
MAY JRC Printed in Japan
Preface

Thank you for buying JRC JCY-1800 Voyage Data Recorder (VDR).

This equipment helps the investigators to detect the cause of marine accident to prevent the
recurrence in the future. The equipment records voyage data, as required by the International
Standard, during the navigation and the hull data of the vessel.

• To ensure your VDR provide optimum satisfaction and service, read this manual carefully
before attempting to operate the JCY-1800.

• We recommend you to carefully store the manual for future reference.

• If you have any problems using this product, this manual will surely help you.

In order to detect the cause of marine accident, the VDR records hull data and navigation data.
If an accident has occurred, it is mandatory to preserve the record data immediately.

In case an accident has occurred, please preserve the record data according to the procedure
described in 1.4.4: “Actions to be taken at the time of an accident”
To ensure the proper operation, we recommend you to read the procedure carefully.

VDR erases older data that has passed for more than 12 hours and
ATTENTION
overwrites the new.
Therefore if you do not operate properly, the recorded data at the time of
accident will be erased automatically after 12 hours.

i
Preface

JCY-1800 conforms to the standard revision that is resolution MSC.214(81)


of the IMO (International Maritime Organization).

* MSC.214(81): It demands the addition of the following functions which help


investigation authorities to download and analyze the recorded
data after an accident.

• Downloading software and Converting software should be equipped in standard


components.

• The time period for downloading the recorded data on board shall not exceed 2.5
hours.

• The recorded data at an accident shall be protected against unauthorized or


inadvertent overwriting.

The following label under the nameplate shows that the JCY-1800 conforms
to resolution MSC.214(81) .

Conforms to IMO MSC. 214(81).

Please preserve the recording data of the VOYAGE DATA RECORDER ( VDR / S-VDR )

Press the CARD STOP SWITCH on the internal Main Control Board for about 10
seconds to preserve the recorded data in the CF CARD after an incident.
The CARD LED ○ and the MEDIA LED ○ will blink for preserving the recorded
data.

Please contact and follow your ships Authorities instructions.


CAUTION If the Authority instructs you to stop recording further data and proceed to the
next port for later downloading of data by an Authority Inspector, please turn off
the power to the VDR/S-VDR at the power switchboard to preserve the recording.

Note: If the unit is not switched off, the recorded data of the incident will be
automatically overwritten after 12 hours further recording and it is required that
ships preserve the recorded data of the incident by International rules and regulations.

ii
Before Operation

SYMBOL MARKS
In this manual, and on the product, we use international warning signs
to call your attention to important items that, if not handled correctly,
can present danger to yourself or property.
These warning note classifications are shown below. Understand the
meanings of the signs before proceeding to read the manual.

DANGER Indicates danger items that, if ignored, may result in


serious personal injury or even death.

WARNING Indicates warning items that, if ignored, may result in


serious personal injury or even death.

CAUTION Indicates cautionary items that, if ignored, may result in


personal injury or physical damage.

Examples of Symbol Marks


The symbol indicates that it calls for a caution or even a
warning.

Electric The illustration in the symbol indicates what should be watched out
shock for. In this case, you have to pay attention to electric shock.

The symbol indicates prohibition.

What is prohibited is depicted in or around the symbol. The sign in


Disassembly the left indicates that disassembly is prohibited.
prohibited

The symbol z indicates a specific action to be taken or an


instruction to be followed, which is depicted in the symbol.

The sign in the left requests you to disconnect the electrical plug
Remove
Plug from the outlet.

Warning Labels
Do not remove, damage, or alter the labels attached to the equipment.

iii
Precautions

Never short-circuit the + and – pins. Never disassemble, modify, destroy, throw
into fire, heat, use with non-specified applications and use after the expiry date.
Above acts may cause leakage of fluid, generation of heat, fire, explosion,
destruction, or injury by heat.

The Power Supply Unit (NBL-327) of this equipment incorporates a battery.


The battery contains dilute sulfuric acid. When the leaked liquid of the battery
had a direct contact with your clothes or skin, wash off with clean water. When
the liquid infringes into your eye, wash with clean water immediately then go to a
doctor.

Do not disassemble or remodel this equipment.


Such an action may result in a fire, an electric shock, or fault of the equipment.

Do not use any power supply voltage other than the specified one.
Such an action may result in a fire, an electric shock, or an equipment fault.

Turn off the power supply switch before connecting or disconnecting the cable to
any external equipment.
Ignoring the caution may result in a fire or an electric shock.

If the power supply cable is damaged, please ask for the replacement to the Sales
Department, the nearest branch company, branch office, sales office, or any agent
of Japan Radio Co., Ltd.
The use of damaged cable may result in a fire or an electric shock.

iv
Precautions

If water enters into the equipment, turn off the power supply switch, pull out the
plug from the outlet, and contact the Sales Department, the nearest branch
company, branch office, sales office, or any agent of Japan Radio Co., Ltd.
The water inside the equipment may result in a fire, an electric shock, or a fault.
Do not attempt checking or repairs on the internal part of the equipment by
yourself.
Checking or repairs by anyone other than qualified maintainer may result in a fire
or an electric shock.
Ask for internal check or repairs of the equipment to the Sales Department, the
nearest branch company, branch office, sales office, or any agent of Japan Radio
Co., Ltd.
If a fault has occurred, turn off the power supply of the equipment, pull out the
plug, and contact the Sales Department, the nearest branch company, branch
office, sales office, or any agent of Japan Radio Co., Ltd.
The continuous use of the equipment may result in a fire or an electric shock.

The Recording Control Unit (NDV-1800) of this equipment incorporates a battery.


The battery needs to be replaced periodically. Continuous use of a life-expired
battery may result in a fire.

Never replace the battery by yourself.


Replacement by anyone other than qualified maintainer may result in a fire, an
electric shock, or a fault.
For battery replacement, contact the Sales Department, the nearest branch
company, branch office, sales office, or any agent of Japan Radio Co., Ltd.

The Recording Control Unit (NDV-1800) of this equipment incorporates a battery.


Used batteries are to be recycled. Regarding the replacement and recycle, contact
the Sales Department, the nearest branch company, branch office, sales office, or
any agent of Japan Radio Co., Ltd. and ask them the replacement and recycle.

The Main Control Board (CDJ-2304), the Remote Maintenance Board (CDK-287) and
the Underwater Acoustic Beacon on the PCU of this equipment incorporate a
lithium battery.
Used batteries are to be recycled. Regarding the replacement and recycle, contact
the Sales Department, the nearest branch company, branch office, sales office, or
any agent of Japan Radio Co., Ltd. and ask them the replacement and recycle.
When disposing of this unit, abide by the local laws and regulations. Contact the
Sales Department, the nearest branch company, branch office, sales office, or any
agent of Japan Radio Co., Ltd. and ask them to replace it without discarding the
battery.

v
Precautions

Do not remove, damage, or alter the labels attached to the equipment.

Do not install the equipment, if the location is infringed by water, humid, dusty, or
with soot.
Ignoring the caution may result in a fire, an electric shock, or a malfunction.

Hands off the equipment if your hand or glove is wet either with freshwater or
seawater.
Ignoring the caution may result in a fire, an electric shock, or a fault.

Be sure to hold the power supply plug when pulling it out from the outlet.
Pulling the electric cable without holding the plug can damage the cable, resulting
in a fire or an electric shock.

Do not remove or insert the power supply plug with wet hand.
Ignoring the caution may result in an electric shock.

Although the UTILITY OUTLET looks like the one of AC100V, the input voltage of
the Recording Control Unit directly comes out from it.
i.e; In case the 220VAC is supplied, the same voltage comes out from UTILITY
OUTLET. Ignoring the caution may result in failures.

If the FAN ABNORMAL LED lights up, either of the two fans of the Power Supply
Unit is out of order and needs to be replaced. Ignoring the caution may result in
failures. Contact the Sales Department, the nearest branch company, branch
office, sales office, or any agent of Japan Radio Co., Ltd. and ask them to replace it.

If the equipment is splashed either with seawater or fresh water, wipe it dry
immediately. Ignoring the caution may result in failures or operational
malfunctions.

Do not use organic solvent such as thinner or benzine to clean the surface. These
agents damage the surface coating.
Be sure to remove dirt and dust, if any, from the surface and wipe it with a clean
dry cloth.

vi
Exterior of System Components

Recording Control Unit Protective capsule Unit Operation Panel Unit

vii
Contents

Contents

Preface ............................................................................................................................................. i
Before Operation ...........................................................................................................................iii
Precautions.................................................................................................................................... iv
Exterior of System Components ..................................................................................................vii
Abbreviations ................................................................................................................................ xi
Glossary ........................................................................................................................................ xii

1. Operation.................................................................................................................................. 1
1.1 Outline of the Equipment ................................................................................................... 1
1.2 Configuration....................................................................................................................... 1
1.2.1 System diagram............................................................................................................ 3
1.3 Starting and Stopping the System ..................................................................................... 4
1.3.1 Starting the system ...................................................................................................... 4
1.3.2 Stopping the system ..................................................................................................... 6
1.4 Detailed Operation Instructions......................................................................................... 7
1.4.1 To stop recording data onto the protective capsule unit............................................. 7
1.4.2 To restart recording data onto the protective capsule unit ........................................ 7
1.4.3 Backing up the data of CF CARD................................................................................ 7
1.4.4 Protecting against overwriting data in CF CARD ...................................................... 8
1.4.5 Actions to be taken at the time of an accident (Guidelines)....................................... 9
1.4.6 Silencing the audible alarm on the Operation Panel Unit ....................................... 10
1.5 Recording Control Unit (NDV-1800)................................................................................. 11
1.5.1 Parts name on Recording Control Unit (NDV-1800)................................................. 11
1.5.2 Power Supply Unit ..................................................................................................... 13
1.5.3 Data Processor Unit ................................................................................................... 16
1.6 Operation Panel Unit (NCG-169) ..................................................................................... 20
1.6.1 Names of parts on the External Operation Board .................................................... 20
1.6.2 How to operate Operation Panel Unit (Normal mode) ............................................. 22
1.6.3 How to operate Operation Panel Unit (on NSK mode)............................................. 28

viii
Contents

2. Specification ........................................................................................................................... 29
2.1 Protective Capsule Unit: PCU (NDH-316A/316)................................................................ 29
2.2 Recording Control Unit: RCU (NDV-1800)......................................................................... 30
2.2.1 Operation panel (Internal)............................................................................................ 30
2.2.2 Data Processor Unit ...................................................................................................... 30
2.2.3 Power Supply Unit: PSU .............................................................................................. 32
2.2.4 External Interface ......................................................................................................... 32
2.2.5 Environmental condition .............................................................................................. 32
2.2.6 General specification..................................................................................................... 33
2.2.7 NSK Interface (Option) ................................................................................................. 33
2.2.8 Radar switching recording function ............................................................................. 33
2.3 Operation Panel Unit: OPU (NCG-169) ............................................................................. 35
2.4 Microphone Unit (NVT-161)................................................................................................ 35
2.5 Connection Box (NQE-3163) ............................................................................................... 36
2.6 Waterproof Microphone Unit (NVT-162) -Option-.............................................................. 36
2.7 Digital Signal Converter (NCT-72) 64CH -Option- ............................................................ 36
2.8 Digital Signal Converter (NCT-63) 16CH -Option- ............................................................ 37
2.9 Radar Interface Unit (NWP-46) -Option- ........................................................................... 38
2.10 General Environmental Condition of Use ........................................................................ 39
2.10.1 Condition of Use ......................................................................................................... 39
2.10.2 Power Supply Environment Conditions .................................................................... 39
2.10.3 Environmental Condition .......................................................................................... 40

3. Maintenance and Inspection ......................................................................................................... 41


3.1 Daily Maintenance ............................................................................................................ 41
3.1.1 Cleaning...................................................................................................................... 41
3.1.2 Checking the expiry date of battery .......................................................................... 41
3.2 Periodic Inspection ............................................................................................................ 42
3.3 Troubleshooting ................................................................................................................. 43
3.3.1 Recording Control Unit (NDV-1800).......................................................................... 43
3.3.2 Operation Panel Unit (NCG-169) .............................................................................. 45

ix
Contents

4. After-sales Service ........................................................................................................................ 49


4.1 To request the service ........................................................................................................ 49
4.2 Disposal of unit .................................................................................................................. 51
4.3 Disposal of used battery .................................................................................................... 51

5. Outside Drawings .......................................................................................................................... 53


5.1 Recording Control Unit: NDV-1800 .................................................................................. 53
5.2 Operation Panel Unit: NCG-169....................................................................................... 54
5.3 Protective Capsule Unit: NDH-316A / 316 ....................................................................... 55
5.4 Connection Box: NQE-3163 .............................................................................................. 57
5.5 Microphone Unit: NVT-161 ............................................................................................... 58
5.6 Waterproof Microphone Unit: NVT-162 ............................................................................ 59
5.7 Digital Signal Converter: NCT-72 (64ch) ......................................................................... 60
5.8 Digital Signal Converter: NCT-63 (16ch) ......................................................................... 61
5.9 Radar Interface Unit: NWP-46 ......................................................................................... 62

6. Block Diagrams ............................................................................................................................. 65


6.1 Recording Control Unit NDV-1800 ................................................................................ 65
6.2 Operation Panel Unit NCG-169 ..................................................................................... 66
6.3 Microphone Unit NVT-161 ............................................................................................. 67
6.4 Waterproof Microphone Unit NVT-162 .......................................................................... 68
6.5 Digital Signal Converter (CH64) NCT-72 ...................................................................... 69
6.6 Digital Signal Converter (CH16) NCT-63 ...................................................................... 71
6.7 Radar Interface Unit NWP-46........................................................................................ 73

x
Abbreviations

Abbreviations

VDR: Voyage Data Recorder


IMO: International Maritime Organization
IEC: International Electrotechnical Commission
PCU: Protective Capsule Unit
RCU: Recording Control Unit
CF CARD: Compact Flash Card
FAN ABN. LED: Fan Abnormal LED
FGB: Frame Grabber Board
OPU: Operation Panel Unit
PCMCIA: Personal Computer Memory Card International Association
HDD: Hard Disk Drive
MCB: Main Control Board
PSU: Power Supply Unit
ARB: Audio Recording Board
RMB: Remote Maintenance Board
NMEA: National Marine Electronics Association
NSK: North Stabilized Kit
UPS: Uninterruptible Power Supply
VESA DMTS: Video Electronics Standards Association – Discrete Monitor Timings Standard
rpm: Revolution per minute
BER: Bit Error Rate
RTC: Real Time Clock
MIC: Microphone Unit
DSC: Digital Signal Converter

xi
Glossary

Glossary

A.861: IMO Performance Standard for VDR


IEC61996: Performance Requirements for VDR
IEC60945: General Requirements
IEC61162: Digital Interfaces Standard
HDT: Heading true sentence header ID of IEC61162-1
VBW: Dual ground/water speed sentence header ID of IEC61162-1
UXGA: Ultra eXtended Graphics Array (1600 x 1200: High resolution pixel)

xii
1. Operation

1.1 Outline of the Equipment

This equipment helps to detect the cause of marine accident to prevent the recurrence in the
future. The equipment records voyage data, as required by the International Standard, during
the navigation and the hull data of the vessel.

1.2 Configuration

The standard configuration of the equipment is shown in Table 1.

Table 1: Standard Configuration

No. Name of Component Type Name Qty Function

1 Protective Capsule Unit NDH-316A 1 y Records data on the recording medium in


the recovery Protective Capsule.
(PCU) or y At the time of sinking, the underwater
acoustic beacon helps the searchers to
NDH-316 detect the position of the PCU.
y The performance of NDH-316A and
NDH-316 is equivalent; both models are
capsule for the JCY-1800 and
interchangeable.
Mounting dimensions also are the same.
2 Connection Box NQE-3163 1 y Connects the PCU and the RCU with a
power supply cable and a LAN cable.
3 Recording Control Unit NDV-1800 1 y Outputs the recorded data to the PCU and
CF CARD.
(RCU) y Inputs radar images, audio data and
IEC61162-1/-2 data.
y Monitors and controls the conditions of the
system.
3-1 Data Processor Unit NDL-46 1 y Main control processing part with a built-in
backup CF CARD.
3-2 Audio Junction Board CQD-2041 1 y An I/F of audio input from the Microphone
and VHF transceiver.
3-3 Power Supply Unit (PSU) NBL-327 1 y Power supply equipped with a secondary
battery and a charging circuit.
4 Operation Panel Unit (OPU) NCG-169 1 y Displays the status of VDR.
ALARM BUZZER, an ALARM ACK
switch, and LEDs are equipped.
5 Microphone Unit (MIC) NVT-161 3 y Records the conversation in the bridge and
outputs the audio to the RCU.

Accessories

6 Spare Parts for RCU 7ZXJD0080 1 y Spares for the NDV-1800


y Fans, Fuse
7 CF Card adapter SLCFADU 1 y for record data playback

8 LAN cable KB-10T5-03LBK 1 y 3m

9 Playback software CYC-315A y Only for the use by the Investigation


1 Authorities.
y Attached inside the NDV-1800.
10 Playback Software / CYC-316A y For the User.
1 y Attached inside the NDV-1800.
Real Time Monitor

1
1. Operation

The options configuration of the equipment is shown in Table 2.

Table 2: Options Configuration

No. Name of Optional Component Type Name Function

1 Microphone Unit (MIC) NVT-161 y To use as an “Exposed” type, remove the flange of
“Built in the ceiling” type.
y Maximum nine sets of microphones can be
installed, inclusive of standard configuration.
2 Waterproof Microphone Unit NVT-162 y Records the conversation in the wing and outputs
the audio to the RCU.
y Maximum nine sets of microphones can be
installed, inclusive of standard configuration and
NVT-161 type.
3 NSK interface board CHM-378 y Optional interface board for heading in synchro or
step signal and ship’s speed by pulse.
y Installed in the NDV-1800.
4 y Outputs IEC61162-1 data converted from 64 dry
Digital Signal Converter (DSC) contacts.
NCT-72
(64CH) y Outputs IEC61162-1 data converted from 8 analog
signals by adding the optional CEF-60.
5 y Outputs IEC61162-1 data converted from 16 dry
Digital Signal Converter (DSC) contacts.
NCT-63
(16CH) y Outputs IEC61162-1 data converted from 8 analog
signals by adding the optional CEF-60.
6 Analog signal Converting y Converts eight analog signals to IEC61162-1 data.
CEF-60
Board y Installed in the NCT-72/63

7 Radar Interface Unit NWP-46 y Required when connecting a radar of UXGA


display.
Accessories

8 y for the NCT-72/63


Spare Parts for the DSC 7ZXJD0092
y Fuse
9 Spare Parts for the RIF 7ZXJD0093 y Spares for the NWP-46
y Fan, Fuse

2
3
Figure 1: System Diagram
DGPS *
(Yard)
AIS *
(Yard)
Speed Log *
(Yard)
Gyro Compass *
(Yard)
Auto Pilot *
(Yard)
Rudder Angle Indicator *
(Yard)
Echo Sounder *
(Yard)
Anemometer *
(Yard)
Engin Telegraph *
(Yard)
Remote Control System *
(Yard)
Other *
(Yard)
X-Band Radar *
(JRC)
Other *
(Yard)
Other *
(Yard)
*
Dry Contact * *
(Yard)
Analog *
(Yard) * R
* G
* B
* H synch
* V synch
From AC Distributor
Dry Contact *
(Yard)
*
Mic-1 MIC1
Analog * *
(Yard) Mic-2 MIC2
*
Mic-4 MIC4
*
From AC Distributor Mic-5 MIC5
*
Mic-7 MIC7(W.P.)
*
Mic-8 MIC8(W.P.)
Gyro Compass [STEP] *
(Yard)
Gyro Compass [Synchro] *
(Yard) *
VHF Telephone No.1
*
VHF Telephone No.2
Speed Log [Pulse] *
(Yard)
*
*
AC220V 60Hz 1 phase
Figure 1 The system diagram of the equipment.
System Diagram 1.2.1
1. Operation
1. Operation

1.3 Starting and Stopping the System

1.3.1 Starting the System

ATTENTION To operate the RCU, the front door has to be unlocked and opened.

y To turn on the equipment, after all units are connected, follow the procedure described below.

1. Starting the Recording Control Unit


1) Unlock the front door with the key and open it.
2) Turn on the PSU.
3) Then POWER LED on PSU lights up.
4) The CARD LED on Main Control Board (MCB) lights up.
5) The REC LED on MCB lights up.

2. Starting the Operation Panel Unit


The PSU in the RCU supplies power to the OPU.
1) Immediately after the PSU in the RCU is turned on, the POWER LED on the OPU lights
up.
2) The Recording LED on the OPU lights up in a few seconds.

3. Starting the Protective Capsule Unit


The PSU in the RCU supplies power to the PCU. When the PSU in the RCU is turned on,
the PCU is activated simultaneously.

4. Starting the Microphone Unit


The ARB in the RCU supplies power to the MIC. When the PSU in the RCU is turned on, the
MIC is activated simultaneously.

5. Starting the Option Units


The option units mean DSC and Radar Interface Unit. The RCU supplies AC power to the
option units. When the RCU is on, the option units are also turned on. The POWER switch
of option units should always be set to ON.

5.1 Digital Signal Converter


1) Undo the four screws and open the top cover.
2) Set the POWER switch to ON.

5.2 Radar Interface Unit


Set the POWER switch on the front panel to ON.

4
1. Operation

6. Checking the System Operation


When the RCU, the OPU, the PCU, the MIC and the option unit are all on, and when they
operate normally, LEDs on the MCB, the PSU in the RCU and the OPU display as follows.

y LEDs on the MCB of the RCU:


1) The REC LED is on.
2) The CARD LED is on.
3) The MEDIA LED is off.

y LEDs on the PSU of the RCU:


1) The POWER LED is on.
2) The BATT. ABN LED is off.
3) The BATT. OP. LED is off.
4) The FAN ABN. LED is off.

y LEDs on the OPU:


1) The POWER LED is on.
2) The RECORDING LED is on.
3) The ALARM LED is off.
4) The ERROR CODE LEDs are all off.

* The two digit LEDs or four digit LEDs that indicates error code (factor)
displays when the equipment detects a fault.

5
1. Operation

1.3.2 Stopping the System

y To stop the equipment, follow the procedures described below.

ATTENTION To operate the RCU, the front door has to be unlocked and opened.

ATTENTION Do not turn off the breaker of the power distribution board while the
system is active. Otherwise, the system is battery-operated by PSU.

ATTENTION Before turning off RCU, be sure to stop recording data to CF CARD by
pressing CARD STOP switch on MCB. Otherwise, data may not be able to
be recorded to CF CARD.

1. Stopping the Recording Control Unit


1) Unlock the front door with the key and open it.
2) Be sure to stop recording data to the CF CARD by pressing the CARD STOP switch on
the MCB.
y Make sure that the CARD LED on the MCB is off.
y Be aware that if the Power Supply is turned off while the CARD LED is on, data may
not be recorded to the CF CARD.
3) Turn off the Power switch of the PSU.
4) Then all the LEDs are turned off.

2. Stopping the Operation Panel Unit


If the PSU in the RCU is turned off, the OPU is also turned off.

3. Stopping the Protective Capsule Unit


If the PSU in the RCU is turned off, the PCU is also turned off.

4. Stopping the Microphone Unit


If the PSU in the RCU is turned off, the MIC is also turned off.

5. Stopping the Option Units


If the PSU in the RCU is turned off, the Option Units are also turned off.

6
1. Operation

1.4 Detailed Operational Description


y In this section the basics of operation are explained.
y The operations can be performed on the MCB of the RCU. (To have access to the RCU, the
front door has to be unlocked and opened.)

1.4.1 To Stop Recording Data onto the Protective Capsule Unit

Do not stop recording data into PCU unless any of the following situations
ATTENTION has arisen.
y while the vessel is in port for essential maintenance purposes.
y when the vessel is laid-up. (docked in)
y upon request by an investigation authority, for example after the vessel
had been involved in a marine incident.

1) Press the REC STOP switch on the MCB.


2) The REC LED on the MCB blinks.
3) After about a minute, the blinking REC LED on the MCB and RECORDING LED on the
OPU are turned off and the recording of the data onto the PCU stops.
4) When the RCU stops recording to the PCU, the Recording Alarm is generated. (Error
code: 22__)
5) When the RCU starts recording to the PCU, the Recording Alarm is canceled. (Error
code: 22__)

1.4.2 To Restart Recording Data onto the Protective Capsule Unit

ATTENTION Once recording is halted while in port or dock, make sure to restart
recording when leaving the port. Otherwise, no data will be found recorded
even when an accident has occurred.

1) Press the REC START switch on the MCB.


2) The REC LED on the MCB lights up.
3) The RECORDING LED on the OPU lights, and the recording of the data onto the PCU
starts.
4) When the RCU starts recording to the PCU, the Recording alarm becomes normal.

1.4.3 Backing Up the Data of the CF CARD


1) Make sure that the CARD LED on the MCB is on.
2) Press the CARD STOP switch on the MCB.
3) The CARD LED on the MCB blinks for about 5 seconds.

7
1. Operation

4) Make sure that the CARD LED on the MCB is turned off. And press the CF CARD EJECT
BUTTON.
5) Take out the CF CARD. Insert the card with a CARD ADAPTER into the PC that has a
PCMCIA slot and copy the data into the PC.
6) After the copy has been finished, insert the CF CARD into the CARD slot on the MCB.
(Be sure that the JRC-label side is pointing right on the CF CARD)
7) Make sure that the CARD LED lights up.

ATTENTION When the CARD LED is left turned off for 10 minutes or more, the MEDIA
LED lights up on the MCB and the OPU gives the alarm with alarm buzzer.
ALARM lamp and ERROR CODE LEDs will be blinking. (Error Code: 31__)
If a CF CARD is inserted into the CARD slot in the MCB, the alarm buzzer
stops and ALARM LEDs will be off.

ATTENTION If the backup to CF CARD is likely to be made frequently, purchase of one


more card is recommended. (CF Card code: 7HRJD0002)

1.4.4 Protecting against overwriting data on CF CARD


JCY-1800 can protect recorded data on CF CARD against unauthorized or inadvertent
overwriting after a marine accident. Recording data does not start onto protected CF
CARD even though JCY-1800 is rebooted or CF CARD is taken out and put into JCY-1800.

JCY-1800 does not stop recording data to PCU.


ATTENTION
When a marine accident occurs, refer to Section 1.4.5 “Actions to be taken at
the time of an accident (Guidelines)”.

1. Protecting against overwriting data on CF card

1) Press CARD STOP switch on MCB until CARD LED and MEDIA LED start flashing
(approx. 10 seconds).
2) The CF CARD is protected against overwriting data.
Flashing of both CARD LED and MEDIA LED shows that the CF CARD is prohibited
against overwriting and protected. Also, OPU generates error alarm as protecting
against overwriting CF CARD (Error code: 03__). Press ACK switch on OPU for
stopping the alarm buzzer.

2. Releasing the protection of CF CARD


In the following cases, release the protection of CF CRAD in order to start recording
data onto CF CARD.

8
1. Operation

• It becomes unnecessary to preserve the recorded data of accident after


transferring the protected data to relevant investigation authorities.
• The recorded data in CF CARD have been protected by mistake.

1) Insert CF CARD protected overwriting into CARD slot on MCB.


2) Both CARD LED and MEDIA LED on MCB flash.
3) Press REC START switch on MCB until CARD LED lights up (approx. 10 seconds).
4) The overwriting protection of CF CARD is released and JCY-1800 starts recording
data onto CF CARD. The error display (Error code: 03__) on OPU is canceled.

1.4.5 Actions to be taken at the time of an accident (Guidelines)

When a marine accident occurs, it is mandatory to store the recorded data of hull and
navigation information until the time of the accident. This section shows some
guidelines on how to preserve the data.
After careful check of the situation of the accident, attempt to preserve the data.
The relevant authority requires the submission of the preserved data. For transferring
the control of the data, contact the Sales Department of Japan Radio Co., Ltd.

1. Preserving the recorded data on CF CARD

Step Actions Operation on RCU


1
Preserve recorded data by protecting Press CARD STOP switch on MCB until
CF CARD at the time of an accident. CARD LED and MEDIA LED start flashing
(approx. 10 seconds). (Refer to Section 1.4.4)
2 Eject CF CARD from RCU. Press CARD EJECT button.

3
Copy the recorded data from the CF
CARD onto HDD of PC. *1

Check the copied data. (Each folder


name under the Log/Audio/Visual
shows the date and time when the
data were recorded.)

4
Return CF CARD into RCU after Confirm both CARD LED and MEDIA LED
copying. start flashing.

*1 Copy all folders and files on CF CARD onto HDD of PC.


“Copy” the recorded data, not to “move” (cut and paste) them.
Do not delete the preserved data on CF CARD until the preserved data in accident
are transferred to relevant authorities.

9
1. Operation

Submit the DVD on which the data of the accident on HDD of PC burnt, when the
relevant authority requires the preserved data.
When submitting the preserved CF CARD to the authority, an alternative CF CARD will
be necessary. If that is the case, contact the Sales Department of Japan Radio Co., Ltd.
When the investigator of relevant authority boards, the investigator downloads the
preserved data from CF CARD in VDR. Always return the overwriting-protected CF
CARD to RCU.

2. Preserving the recorded data in Protective Capsule Unit


If the relevant authority instructs you to stop recording further data and proceed to the
next port for later downloading of data by the authority’s investigator, stop recording
onto PCU.

Step Actions Operation of RCU


1 Stop VDR system. Turn off POWER switch.
(Refer to Section 1.5.2.)

If the key to open the front door of RCU is misplaced or lost, turn off the power to VDR at
power switchboard to preserve the recorded data. After 2 hours of turning it off, it
automatically stops recording and becomes power OFF.

The danger of life to the crew is pressing as the accident is very serious…
ATTENTION
Escape from the vessel first. Leave VDR as it is.
VDR automatically stops recording data after 2 hours of the main power cut.
(When the evacuation is necessary due to the accident, the operation to
preserve recorded data is not necessary.) PCU will be collected and the
recorded data will be obtained therewith.

To copy data from CF CARD, the PC with PCMCIA slot and 2GB of available
ATTENTION
volume on HDD are needed. If the vessel does not have the PC which meets
such conditions, contact our business office. A standard laptop PC has a
PCMCIA slot.

1.4.6 Silencing the Audible Alarm on the Operation Panel Unit


In case the alarm buzzer on the OPU sounds:
1) Press the ACK switch on the OPU.
2) Then the alarm buzzer on the OPU stops.
3) If more than one alarm are detected, press the ACK switch as many times as the alarms
are detected.

10
1. Operation

1.5 Recording Control Unit (NDV-1800)

1.5.1 Names of Parts of the Recording Control Unit (NDV-1800)

1) Keyhole

Figure 2: Parts Name on Recording Control Unit


(The front door is closed)

2) Power Supply Unit

3) Data Processor Unit

4) I/F for connecting to external signals


(connection ports are located under the cover)

5) Battery

Figure 3: Parts Name on Recording Control Unit


(The front door is open.)

11
1. Operation

Table 3: Names and Functions of the RCU


No. Names and Functions
1) Keyhole:
Used for opening and closing the front door.
2) Power Supply Unit :
Incorporated into the RCU. It has an external battery and supplies
power to PCU, OPU and MIC in case of power failure.
3) Data Processor Unit:
The main processing unit of the RCU. It has a CARD slot for a backup CF
CARD.
4) I/F for connecting external signals:
• RGB Connector Panel:
RGB connector relay panel for connecting to the RADAR (BNC
connector)
• AUDIO Interface Board:
Interface board for connecting to the MICs and VHF
• Terminals:
Terminals for inputting IEC61162-1/2 signals and connecting to the
PCU and the OPU
• Utility Outlet:
The electricity outlet for maintenance facilities (AC100-240V)
5) Battery:
Battery is connected to the PSU.
Supplies DC24V power for 2 hours to the RCU, the PCU, the OPU and
the MIC.

CAUTION
Although the UTILITY OUTLET looks like the one of AC100V, the input voltage
of the RCU directly comes out from it.
i.e; In case the 220VAC is supplied, the same voltage comes out from UTILITY
OUTLET. Ignoring the caution may result in failures.

12
1. Operation

1.5.2 Power Supply Unit

1.5.2.1 Names and functions of each part of the Power Supply Unit

1) POWER switch 3) POWER LED 8) BATTERY VOLTAGE TEST TERMINAL

7) BLACKOUT 9) FAN
TEST switch

2) FUSE 4) BATTERY ABN. LED 5) BATTERY OP. LED 6) FAN ABN. LED

Figure 4. Names of parts of the PSU

Table 4: Names and Functions of the PSU

No. Names and Functions


1) POWER switch:
The main power switch of the RCU.
2) FUSE:
Glass fuse (5A) for protecting the power supply unit from an entry of
surge.
3) POWER LED:
Lights when the AC power is supplied from outside. It is turned off when
the power is supplied by the Battery at the time of blackout.
4) BATTERY ABN. LED:
Lights up when the Battery is not ready.
5) BATTERY OP. LED:
Lights up when the Battery supplies power.
6) FAN ABN. LED:
Lights up when either of two fans stops operation.
7) BLACKOUT TEST switch:
Used to test the blackout functions. When it is held down, the AC power
from outside is shut out. When it is released, the power is restored.
8) BATTERY VOLTAGE TEST TERMINAL:
Used to measure the voltage of the Battery by a multimeter. The charging
voltage can be monitored when the equipment is operated by AC power.
To monitor the battery voltage, be sure that the POWER switch is off.
(Battery voltage: +24V or more)
9) FAN (2 sets: Right side of the PSU):
Used to cool down the AC/DC power source. (Its rpm can be monitored)

13
1. Operation

1.5.2.2 How to operate Power Supply Unit

1. Starting power source:


1) Turn on the POWER switch.
2) Then the POWER LED lights up.

2. Stopping power source:


1) Before turning off the power source, press the CARD STOP switch to stop the
backup of CF CARD.

ATTENTION Before turning off the power source, be sure that the CARD LED on the MCB
is off. Turning off the POWER switch while the CARD LED is on may result
in the physical damage to the CF CARD. Make sure to stop the backup by
pressing the CARD STOP switch.

2) Press the CARD STOP switch on the MCB.


3) Make sure that the CARD LED on the MCB is off.
4) Turn off the POWER switch.
5) Then all the LEDs are turned off.

3. Blackout Test:
1) Hold down the BLACKOUT TEST switch. (While it is held down, AC power input
is cut off.)
2) While the BLACKOUT TEST switch is held down, check the following items. If
they all happen, the Battery is in normal operation.

y The POWER LED of the PSU is turned off.


y The BATTERY OP. LED of the PSU lights up.
y The alarm buzzer of the OPU sounds.
y The ALARM LED and the ERROR CODE LEDs on the OPU blinks. ( Error
Code: 10__ )
yThe POWER LED on the OPU blinks.

3) Release the BLACKOUT TEST switch, then the following happen.

y The POWER LED of the PSU lights up.


y The BATTERY OP. LED of the PSU is turned off.
y The alarm buzzer of the OPU stops sounding.
y The ALARM LED and the ERROR CODE LEDs on the OPU are turned off.
y The POWER LED on the OPU lights up.

14
1. Operation

4. If FAN ABN. LED lights up:


Follow the procedures described in 3.3: Trouble Shooting.

CAUTION
If the FAN ABN. LED lights up, either of the two fans of the PSU is out of order
and needs to be replaced. Ignoring the caution may result in failures. Please
contact the Sales Department, the nearest branch company, branch office, sales
office, or any agent of Japan Radio Co., Ltd. and ask them to replace.

15
1. Operation

1.5.3 Data Processor Unit

1.5.3.1 Names of each part of the Data processor Unit

9) AUDIO IN CONNECTOR
17) RGB1 IN CONNECTOR
7) CF CARD
18) RGB2 IN CONNECTOR
2) REC START SWITCH

8) CF CARD EJECT BUTTON


12) RMS OP. LED
1) REC LED

4) CARD LED 13) RMS SYS. LED

5) MEDIA LED 14) DATA LED

15) HUB (JRC-LAN)

3) REC STOP SWITCH

6) CARD STOP switch 16) LAN CONNECTOR (EXT-LAN)

10) HUB (VDR-LAN)


19) LAN CONNECTOR
(VDR-LAN)
11) LAN CONNECTOR (JRC-LAN)

MAIN CONTROL BOARD REMOTE MAINTENANCE BOARD FRAME GRABBER BOARD


(AUDIO RECORDING BOARD on MCB)

Figure 5: The Data Processor Unit

Table 5: Names and Functions of each BOARD in the Data Processor Unit

Board name Function


MAIN CONTROL BOARD The main processing module of the RCU.
(MCB) Records all the data to the PCU and the CF CARD.
Used to receive the IEC61162-1/2 signals (CH01-CH16) and
AUDIO signals.

REMOTE MAINTENANCE Used to receive the IEC61162-1/2 signals (CH17-CH32), and


BOARD send them to the MCB.
(RMB)
FRAME GRABBER BOARD Used to capture the image signals from the RADAR, compress
(FGB) -Option- them, and send them to the MCB via HUB.

16
1. Operation

Table 6: Names and Functions of the Data Processor Unit

No. Names and Functions


1) REC LED (MCB):
Lights up when the data are being successfully recorded into the PCU.
2) REC START switch (MCB):
Used to restart recording the data into PCU.
When releasing protection of CF CARD, press REC START switch until CARD LED lights
up (approx. 10 seconds).
3) REC STOP switch (MCB):
Used to stop recording the data into the PCU.
4) CARD LED (MCB):
Lights up when the data are being successfully recorded into the CF CARD.
Turned off when the CF CARD is in operation.
CARD LED flashes with MEDIA LED when recorded data in CF CARD is protected.
5) MEDIA LED (MCB):
Blinks when a CF CARD is not loaded or does not record data correctly.
MEDIA LED flashes with CARD LED when recorded data in CF CARD is protected.
6) CARD STOP switch (MCB):
Used to stop recording the data into the CF CARD.
When protecting recorded data on CF CARD, press CARD STOP switch until both CARD
LED and MEDIA LED start flashing (approx. 10 seconds).
7) CF CARD (MCB):
Used as an alternative record media onto which the same data as the one stored in the
PCU are recorded.
8) CF CARD EJECT BUTTON (MCB):
Used to remove CF CARD from the system. Confirm that CARD LED is off then press
CARD STOP switch to eject the CF CARD.
9) AUDIO IN CONNECTOR (MCB):
Used as a connector through which audio signals that are received from the MIC and the
VHF radio equipment are input. It is connected to the Audio Junction Board of the
external interface.
10) HUB (MCB):
The switching HUB function with four port is built in MCB.
One of the components of VDR-LAN.
11) LAN CONNECTOR (MCB):
Connected to the external HUB Unit.
12) RMS OP. LED (RMB):
Lights up when the RMB is operating.
13) RMS SYS. LED (RMB):
Lights up when the RMB is operating abnormally.
14) DATA LED (RMB):
Lights up when the RMB can not receive any data.
15) HUB (RMB):
The HUB Unit with four port switching function.
One of the components of JRC-LAN.
16) LAN CONNECTOR (RMB):
Connected to the external HUB Unit.
17) RGB1 IN CONNECTOR (FGB):
Used as a connector through which the image signals from the main RADAR are input.
Connected to the RGB connector panel.
18) RGB2 IN CONNECTOR (FGB):
Used as a connector through which the image signals from the sub RADAR are input.
Connected to the RGB connector panel.
19) LAN CONNECTOR (FGB):
Connected to the HUB Unit of the MCB.
17
1. Operation

1.5.3.2 How to operate the Data Processor Unit

3. To stop the recording of data into the Protective Capsule Unit

ATTENTION Do not halt the recording of data onto the PCU while the ship is
navigating. Otherwise no data would be recorded, even in case of an
accident.

1) Press the REC STOP switch on the MCB.


2) The REC LED on the MCB blinks.
3) After about a minute, the blinking REC LED on the MCB and RECORDING LED
on the OPU are turned off and the recording of the data into the PCU stops.
4) When the RCU stops recording to the PCU, the Recording Alarm is generated.
(Error code: 22__)

4. To restart the recording of data into the Protective Capsule Unit

1) Press the REC START switch on the MCB.


2) The REC LED on the MCB lights up.
3) The RECORDING LED on the OPU lights, and the recording of the data into the
Protective capsule Unit starts.
4) When the RCU restarts recording to the PCU, the Recording alarm stops.

5. To back up the data stored in the CF CARD

ATTENTION Do not remove the CF CARD while the CARD LED on the MCB is on. It
can damage the CF CARD. Make sure that CARD LED is off.

1) Make sure that the CARD LED on the MCB is on.


2) Press the CARD STOP switch on the MCB.
3) The CARD LED on the MCB blinks for about 5 seconds.
4) Make sure that the CARD LED on the MCB is turned off. And press the CF CARD
EJECT BUTTON.
5) Take out the CF CARD. Insert the CF CARD with a CARD ADAPTER into the PC
that has a PCMCIA slot and copy the data into the PC.
6) After the copy has been finished, insert the CF CARD into the CARD slot on the
MCB. (Be sure that the CF CARD JRC-label side is pointing right.)
7) Make sure that the CARD LED lights up.
8) Then the recording of data into the CF CARD starts automatically.
9) The old data which had been recorded over 13.5 hours before in the CF CARD is
erased.

18
1. Operation

ATTENTION When the CARD LED is left turned off for 10 minutes or more, MEDIA
LED lights up on MCB and OPU gives the alarm with alarm buzzer.
ALARM lamp and ERROR CODE LEDs start blinking. (Error Code:
31__ ) If a CF CARD is inserted into the CARD slot in MCB, the alarm
buzzer stops and ALARM LEDs goes out.

6. Protecting against overwriting data on CF card

1) Press CARD STOP switch on MCB until CARD LED and MEDIA LED start flashing
(approx. 10 seconds).
2) The CF CARD is protected against overwriting data.
Flashing of both CARD LED and MEDIA LED shows that the CF CARD is
prohibited against overwriting and protected. Also, OPU generates error alarm
as protecting against overwriting CF CARD (Error code: 03__). Press ACK switch
on OPU for stopping the alarm buzzer.

7. Releasing the protection of CF CARD


In the following situations, release the protection of CF CRAD in order to start
recording data onto CF CARD.
• It becomes unnecessary to preserve the recorded data of accident after
transferring the protected data to relevant investigation authorities.
• The recorded data in CF CARD have been protected by mistake.

1) Insert CF CARD protected overwriting into CARD slot on MCB.


2) Both CARD LED and MEDIA LED on MCB flash.
3) Press REC START switch on MCB until CARD LED lights up (approx. 10 seconds).
4) The overwriting protection of CF CARD is released and JCY-1800 starts recording
data onto CF CARD. The error display (Error code: 03__) on OPU is canceled.

19
1. Operation

1.6 Operation Panel Unit (NCG-169)

1.6.1 Names and functions of each part of the External Operation Board

7) HEADING LED

HEADING
8) ALARM DETAIL LED
ALARM DETAIL
1) POWER LED POWER 9) MODE switch
MODE
2) RECORDING LED RECORDING 10) ERROR CODE LED
SYSTEM CODE

3) ALARM LED ALARM

11) CURSOR switch


ACK DIM

5) ALARM ACK switch


ENT

12) ENTER switch

4) DIMMER switch
6) ALARM BUZZER NCG-169 VDR OPERATION PANEL

Figure 6: Operation Panel Unit

Table 7: Names and Functions of the OPU

No. Names and Functions


1) POWER LED:
Lights when the RCU is in normal operation with the power supplied from
outside.
Blinks when there is a blackout during the operation. If the blackout lasts, it is
turned off in 2 hours. (automatic shutdown)
2) RECORDING LED:
Lights when the output data from the RCU is recorded into the PCU.
3) ALARM LED:
Blinks when an error(s) is (are) detected in the VDR. Pressing the ALARM ACK
switch changes it from blinking to lighting.
It is turned off when all the errors detected are restored to normal.
4) DIMMER switch:
Controls the brightness. Press the switch then the brightness changes cyclically.
5) ALARM ACK switch:
Used to stop the alarm buzzer. When more than one error are detected, press
the switch as many times as the errors arose.
6) ALARM BUZZER:
Sounds when an error is detected in the VDR. To silence the alarm press the
ALARM ACK switch.

20
1. Operation

No. Names and Functions


7) HEADING LED:
Lights when the OPU is operated in NSK mode.
The HEADING LED blinks when the initial value of heading is not registered.
The NSK mode is usable when the optional NSK-I/F Board is installed inside
RCU.
If the NSK-I/F Board is not installed, the HEADING LED is turned off all the
time.
8) ALARM DETAIL LED:
Lights when the OPU is operated in normal mode.
The ALARM DETAIL LED is always on as long as VDR is operated without any
problem.
9) MODE switch:
Used to change the operation mode.
Press the switch then the operation mode is changed from normal mode to NSK
mode or vice versa. In case the heading data is supplied in serial format, NSK
mode is not necessary therefore the mode is not changed by the switch.
The NSK mode is usable only when the optional NSK-I/F Board is installed in the
RCU.
10) ERROR CODE LED:
Four digit LEDs. They stand for ERROR code or HEADING value.
• Normal mode;
The error code of four or two digits that show the error factor displays when
the error occurs.
• NSK mode;
HEADING value when the HEADING LED lights up.
11) CURSOR switch:
Used to display the next error code when two or more errors arose or to set the
initial value of heading.
• Normal mode;
Press the UP/DOWN switch or RIGHT/LEFT switch in order to display other
error codes.
• NSK mode;
Press the RIGHT/LEFT switch to select the digit where the value is to be
altered.
Press the UP/DOWN switch to select the heading value that is displayed on
ship’s Gyro.
12) ENTER switch:
Used to display the software version or to register the initial value of heading.
• In Normal mode;
When ENTER switch is pressed in normal mode, The content that displays on
4 digits LED is switched to SOFTWARE VERSION display mode.
When ENTER switch is pressed during SOFTWARE VERSION display mode,
the operation mode returns to Normal mode of error code display.
SOFTWARE VERSION display mode automatically returns to Normal mode
after five minutes pass. While displaying SOFTWARE VERSION on 4 digits
LED, “ALARM DETAIL LED” flashes.
• NSK mode;
The entered heading angle is registered to the VDR as an initial value.
The operation mode is returned to the normal mode after entry.

* Refer to the clause 1.6.3 for details of the NSK mode.

21
1. Operation

1.6.2 How to operate the Operation Panel Unit (Normal mode)

1. If an error is detected:
1) The alarm buzzer sounds if an error is detected in the VDR.
2) The ALARM LED blinks.
3) The four or two digits ERROR CODE LEDs flash.
4) Press the ALARM ACK switch until the buzzer stops.
5) Check the contents of the error code referring to table 8.
6) Follow the procedure described in 3.3: Trouble Shooting.

2. If multiple errors are detected:


1) The alarm buzzer sounds if a new error is detected in the VDR.
2) The ALARM LED blinks.
3) The latest four or two digits ERROR CODE LEDs flash.
4) Press the ALARM ACK switch until the buzzer stops.
5) When two or more errors are detected at a time, press the switch as many times as the
errors arose.
6) Check the contents of the error code referring to table 8.
• Auto scroll
When multiple errors are detected, different four digits ERROR CODE LEDs light
up every 3 seconds to indicate all the errors raised.
• Manual scroll
Press the UP/DOWN switch or RIGHT/LEFT switch in order to change the error
code.
7) Follow the procedure described in 3.3: Trouble Shooting.

3. In case of blackout:
1) The alarm buzzer sounds in case a power failure happens.
2) Both POWER LED and ALARM LED blink.
3) The ERROR CODE LEDs blink indicating “10__”.
4) Press the ALARM ACK switch to stop the buzzer. However, during the blackout, unless
the ALARM ACK switch is turned on within 2 minutes, the alarm buzzer stops of itself.
5) At the time of power failure, only the voice from the MIC is recorded. The other data
are not recorded at all.
6) If the power failure lasts 2 hours, the PSU in the RCU automatically cuts off the power
output.
7) If the detected power failure is false, follow the procedure described in 3.3: Trouble
Shooting.
8) If the blackout is restored in less than 2 hours, the RCU resumes normal operation
automatically.

22
1. Operation

4. To adjust the brightness of LEDs:


1) Press the DIMMER switch to adjust the brightness of the LEDs.
2) Press the switch again then the LEDs become darker. The brightness changes
cyclically.
3) Even at the darkest brightness, the LED is still on.

5. To check the version of the software


1) Press the ENTER switch on the OPU.
2) The operation mode is changed to the Software version display mode.
3) The ERROR CODE LEDs show the software version.
4) When the software version is shown, the ALARM DETAIL LED is blinking.
5) When the ENTER switch is pressed at this stage, the operation mode is returned to the
Normal mode.
6) Even when the ENTER switch is not pressed, the operation mode is returned to the
Normal mode in five minutes.

23
1. Operation

Table 8: ERROR code table of OPU (1/3)

ALARM DETAIL
CATEGORY CONTENTS
SYSTEM CODE

0 0 System Initial error


There is a discrepancy in the configuration data between
the PCU and the RCU.
0 1 Heading angle initial value alarm
(Only when inputted from NSK I/F)
The initial value of HEADING is not registered.
(Required to input heading angle).
0 3 Protecting CF CARD
CF CARD is protected against overwriting data.
1 0 PSU Blackout alarm
The PSU is in operation with the power supplied from the
backup Battery.
1 1 PSU FAN alarm
One of two fans inside PSU is out of order.
1 2 PSU connection alarm
The cable between the PSU and the Mother Board is
disconnected.
2 0 Capsule Capsule control error
RCU can not record data onto PCU since PCU is outputting
error response.
2 1 Bit Error Rate error
The PCU sensed higher BER than 10-8 during the readout
check of the recorded data.
2 2 Recording stop alarm
VDR stops recording data as the REC STOP switch on the
RCU has been pressed.
2 3
Capsule LAN error
RCU can not record data onto PCU since RCU is unable to
communicate with PCU.

24
1. Operation

Table 8: ERROR code table of the OPU (2/3)

ALARM DETAIL
CATEGORY CONTENTS
SYSYTEM CODE
3 0 MCB MCB Initialize error
A fault has been detected in the MCB.
3 1 CF CARD alarm
Ten minutes or more has passed since the CF CARD was
taken out.
3 2 CF CARD media error
The CF CARD does not record data correctly.
3 3 Time adjustment error
Time data is not received from GPS, therefore the internal
clock of VDR cannot be calibrated.
3 4 RTC error
An internal lithium battery for a Real Time Clock IC has
reached the life.
3 5 EEPROM check sum error
An abnormal data has been detected in configuration data
registered on the EEPROM of the MCB.
3 6 EEPROM access error
The access to the EEPROM IC on the MCB, where setup
data are registered was denied.
3 7 Flash ROM check sum error
An abnormal data has been detected in the configuration
data registered on the Flash ROM of the MCB.
3 8 Wrong data registered to MCB
The value registered to the configuration data of the
EEPROM on MCB is not correct.
4 0 ARB ARB Initialize error
A fault has been detected in the ARB on the MCB.
4 1 ARB control error
The MCB did not fetch the audio data from the ARB
successfully.
4 2 ARB error
The ARB did not compress/decompress the audio signal
successfully.
5 1 MIC MIC test error
: An abnormality has been detected during the microphone
checkups carried out at the startup of the equipment and
9 every 12 hours during the operation. The second digit
(1-9) identifies the MIC out of order.

25
1. Operation

Table 8: ERROR code table of the OPU (3/3)


ALARM DETAIL
CATEGORY CONTENTS
SYSYTEM CODE

Serial data Serial data (IEC61162-1/2 ) reception error


6 0 * * (NMEA) The input received from the sensor is not normal.
"**" identifies the sensor that has sent the unreadable
data. Refer to table 9.
Serial data (IEC61162-1/2 ) setup error
6 1 * * The setup to receive NMEA serial data is not correct.
"**" identifies the equipment. Refer to table 9.
7 0 FGB CH1 Radar image data error
The FGB does not receive RGB signals from Radar
connected to CH1.
7 1 CH2 Radar image data error
The FGB does not receive RGB signals from Radar
connected to CH2.
7 2 FGB Communication error
The MCB does not communicate with the FGB normally
via LAN.
7 3 FGB Setup data reception error
The MCB does not receive the setup data of FGB
successfully.
7 4 FGB Control error
The MCB did not communicate with FGB successfully.
7 5 FAN alarm of NWP-46
FAN built in NWP-46 (Radar Interface Unit) is out of order.
7 6 FGB Real time monitor data transmission error
The IP address for transmitting image data is not
registered in the FGB yet.
8 0 RMB RMB communication error
The MCB does not communicate with the RMB normally
via LAN.
8 1 RMB Control error
The MCB did not communicate with RMB successfully.

26
1. Operation

Table 9: The conversion table of a code and equipment

A connection channel is displayed when the equipment which is not defined by the following
table is connected. The codes from 01 to 16 identify the connection channel.
ALARM DETAIL
Equipment
SYSYTEM CODE

6 0/1 4 1 GPS
4 2 AIS
4 3 Speed Log
4 4 Gyro Compass
4 5 Auto Pilot
4 6 Rudder Angle Indicator
4 7 Echo Sounder (Bow)
4 8 Anemometer
4 9 Engine Telegraph
5 0 M/E Remote Control System
5 1 ECDIS
5 2 Thruster
5 3 Bow1 Thruster
5 4 Bow2 Thruster
5 5 Stern1 Thruster
5 6 Stern2 Thruster
5 7 Hull Stress Monitor
5 8 Radar
5 9 Echo Sounder(Stern)
6 0 DSC 1 (VDR option unit)
6 1 DSC 2 (VDR option unit)
6 2 DSC 3 (VDR option unit)
6 3 DSC 4 (VDR option unit)
6 4 DSC with optional A/D Converter 1 (VDR option unit)
6 5 DSC with optional A/D Converter 2 (VDR option unit)
6 6 DSC with optional A/D Converter 3 (VDR option unit)
6 7 DSC with optional A/D Converter 4 (VDR option unit)
6 8 NAV-I/F unit (VDR option unit)
6 9 Spare
7 0 External NSK unit (NCT-27)
7 1 Main GPS and Sub GPS with Switcher
7 2 Sub GPS (connection with a CH different from the Main GPS)
7 3 Magnetic Compass
3 3 NSK Interface board for Heading (VDR option board)
3 4 NSK Interface board for Ship’s speed (VDR option board)

27
1. Operation

1.6.3 How to operate the Operation Panel Unit (on NSK mode)

The NSK mode is usable only when the option NSK-I/F Board is installed in the RCU. The
board is needed to receive ship’s heading angle either in Synchro or in step mode or to
input log speed in pulse. When the NSK-I/F Board is not activated, the OPU is not operated
in NSK mode.

1. Establish the initial value of HEADING:


1) Turn on the RECORDING CONTROL UNIT.
2) The alarm buzzer sounds as the initial HEADING angle has not been registered.
3) ALARM LED and the four digit ERROR CODE LEDs (“01__ “and “6033”) blink.
4) Press the ALARM ACK switch until the buzzer stops.
5) Press the MODE switch, and the OPU is operated in NSK mode.
6) The HEADING LED blinks until the initial value will be registered.
7) Confirm the HEADING angle displayed on ship’s Gyro.
8) Enter the value to the OPU.
• The blinking digit accepts input. Select the digit with RIGHT/LEFT switch.
• Adjust the input value by UP/DOWN switch.
• Repeat above procedure until the HEADING angle is inputted successfully.
9) Press the ENTER switch, and the initial value of HEADING is registered into the VDR.
10) The HEADING LED lights up.
11) The four digit LED repeats the heading angle shown on ship’s Gyro.

2. Return to the Normal mode from the NSK mode:


To return to the normal mode follow the next procedure.
• Press the MODE switch.
• The Mode automatically returns back to Normal mode in five minutes.

28
2. Specification

2.1 Protective Capsule Unit: PCU (NDH-316A/316)

(1) Function:
The PCU is not a float-free model but a fixed type. The PCU records navigation data, hull
data, conversation in the bridge, conversation over VHF radio, and radar image data to
the recording medium in the PCU.
When submerged, the Underwater Acoustic Beacon with PCU, which is battery-powered,
transmits pulsed acoustic signal for capsule searchers.

(2) Performance:
a) Interface:
1) Standard: IEEE802.3 (10Base-T/ 100Base-TX)
2) Protocol: TCP/IP
b) Recording duration and capacity:
1) Duration: 12 hours
2) Capacity: 2.0GB (flash memory)
c) Data Recording Interval:
1) Sensor Data: depends on the input from the sensors (normally 1 second)
2) Audio Data: continuous (1 audio file / minute)
3) Image Data: 1 image per 15 second
d) Acoustic underwater beacon:
1) Operating frequency: 37.5kHz ±1kHz
2) Operating time: minimum 30 days after submerged in the water
3) Detectable range: 1800m - 3600m (depends on surrounding environment)
4) Battery life: maximum 5-years

(3) Environmental condition


There shall be neither the damage of the final record media nor the loss of recorded data
under the conditions shown below.
a) Shock: A half sine-wave pulse of 50G, with an interval of 11msec
b) Penetration: A mass of 250 kg with a pin of 100mm diameter, dropped
from 3m
c) Fire: 10 hours with 260 °C fire
1 hour with 1100 °C fire
d) Deep-sea water pressure: 60 Mpa (equivalent to 6000m of depth)
General environmental condition
a) Operating temperature: -25°C to +55°C (IEC 60945 exposed type)
b) Storage temperature -55°C to +70°C (IEC 60945 exposed type)
c)Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G

(4) General specification


a) Input voltage range: 19.5 - 36.5VDC
b) Power consumption: 3W
c) Dimensions: NDH-316A 186(W) x 209(D) x 217(H) mm
NDH-316 182(W) x 206(D) x 218(H) mm
d) Mass: NDH-316A 7.9kg
NDH-316 8.7kg
e) Color: fluorescent orange
29
2. Specification

2.2 Recording Control Unit: RCU (NDV-1800)

2.2.1 Operation panel (Internal)

(1) Performance:
a) Button operation:
1) Recording stop: Stop to record data to PCU
2) Recording restart: Restart to record data to PCU
3) CF Card recording stop: Stop to record data to CF card.
(enables to take out CF card from RCU)

4) Protecting CF Card: Protecting recorded data on CF card against


overwriting and releasing protection of CF card
b) LED Indication:
1) Recording status Recording / Recording stop
2) CF card status Recording / Recording stop (enables to eject CF card)
/ Protecting
3) CF card Media alarm Access error to CF card

2.2.2 Data Processor Unit

(1) Function:
a) Control of recording navigation and hull data to PCU.
b) Collects data of navigation and hull condition according to IEC61162-1/2.
The data collected are as follows according to the IEC61996 4.6 (IMO A.861 5.4).
1) Date and Time (UTC)
2) Ship’s position measured by the electronic position fixing system
3) Ship’s speed (over ground/water)
4) Ship’s heading with a gyrocompass or magnetic compass
5) Under keel clearance
6) Main alarms (indicated in the bridge)
7) Rudder order and response data
8) Engine order and response data
9) Hull opening status (for RO-RO passenger ships and ferry ships only)
10) Watertight door / Fire door status
11) Bow acceleration and hull stress data
(only for the ships mandatorily having hull stress indicator)
12) Wind direction / wind speed data
(only when the vessel is equipped with anemometer)
c) Capturing, encoding and recording of conversation audio on the bridge, VHF
communications audio and radar image shown on the display
d) Copying recorded data to CF card for backup and protecting the recorded data on CF
CARD
e) Monitoring and control of the system

30
2. Specification

(2) Performance:
a) Communication to PCU:
1) Standard: IEEE802.3 (10Base-T/ 100Base-TX )
2) Protocol: TCP/IP
b) Sensor data input :
1) Input channel: up to 32 (channels)
2) Data input interface: IEC61162-1/-2 (RS-422)
3) Recording interval: depends on the input from the sensors (normally 1 second)
c) Bridge audio input:
1) Input channel: up to 9 (channels)
2) Input sensitivity: 6kHz
3) Recording interval: continuous (1 audio file / minute)
d) VHF communications input (audio):
1) Input channel: up to 3 (channels)
2) Input sensitivity: 3.5kHz
3) Input level: 0 dBm 600-ohm balance
4) Recording interval: continuous (1 audio file / minute)
e) Radar image data input (input of No1. X band radar is recommended):
1) Input channel: 2 (channels)
Auto selection of a radar image from both channels
(If the radar is of JRC make, automatic selection of
in-operation radar is possible.)
* Refer to the clause 2.2.8 for details.
2) Input interface: analog RGB/Hs/Vs
- RGB: 0.7Vp-p (video signal)
- Hs: TTL
- Vs: TTL
3) Resolution: 640 x 350 – 1600 x 1200 pixel (conforms to VESA
DMTS)
4) Refresh rate: 60 - 85 Hz (conforms to VESA DMTS)
(Resolution 1600 x 1200 pixel 60Hz only)
5) Recording interval: 1 image every 15 seconds
f) Recording data backup:
1) Media: CF card
(Adapter for PCMCIA type-2 is attached to the RCU.)
2) Storage capacity: 2.0GB
g) Blackout processing:
1) Recording duration: 2 hours while blackout
(during the blackout, only the conversation in the
bridge is recorded)
2) Restoration time required: less than 1 minute
(Recovery time from blackout operation to normal
operation on restoration of ship’s mains.)
h) GPS select signal input:
1) Interface: Dry (voltage free) contact closure
(Commonly used with External Contact Input )
2) Operation: Recording GPS selection (active open/close)
i) RADAR select signal input: (So far only JMA-9900, JMA-900M, JMA-5300 supply
this signal)
1) Interface of JRC radar: IEC61162-1 (RS-422)
2) Operation of JRC radar: Active radar selection by JRC original sentence
31
2. Specification

3) Interface with other radar: Dry (voltage free) contact closure


(Commonly used with External Contact Input )
4) Operation of other radar: Recording RADAR selection by dry contact closure
(active open/close)
j) External Contact Input (dry contact):
1) Number of input: maximum 3 dry contacts (voltage free)
(Commonly used with the input signals which select
RADAR or GPS.)
2) Output sentences: Registers sentences at the time of their making and
opening

2.2.3 Power Supply Unit: PSU

(1) Function:
a) Power supply to RCU and PCU in normal operation
b) Power supply to RCU and PCU for 2 hours on blackout.

(2) Performance:
a) Input voltage range: 100 - 120VAC +/- 10% 1-phase 50/60Hz +/-5%
200 - 240VAC +/- 10% 1-phase 50/60Hz +/-5%
(Auto switching)
b) Output voltage: 5VDC, 12VDC, 24VDC
c) Maximum power output: 140VA
d) Battery capacity: 24VDC 5Ah
e) Expectant battery age: max 4-years
(Depending on circumstance. This age is based on
ambient operating temperature: 25 deg., load 70%)

2.2.4 External interface

a) External alarm lamp output:


1) Interface: Dry (voltage free) contact closure
2) Operation: System down (normal-close or open)
3) Current: 1A or less at 24VDC / 0.5A or less at 125VAC
b) External alarm buzzer output:
1) Interface: Dry (voltage free) contact closure
2) Operation: System down (normal-close or open)
3) Current: 1A or less at 24VDC / 0.5A or less at 125VAC

2.2.5 Environmental condition

(1) Operating temperature: -15°C to +55°C (IEC 60945 protected type)


(2) Temperature and humidity: +40°C, 93%
(3) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G

32
2. Specification

2.2.6 General specification

(1) Power voltage: 100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
(2) Power consumption:
(including capsule unit & operation panel unit & microphone phantom power)
90VA in UPS battery charge
50VA in normal operation
(3) Dimensions: 419.5(w) x 250(d) x 480(h) mm
(4) Mass: 23.0kg
(5) Color: N7 semi-gloss texture

2.2.7 NSK interface (Option)

(1) Function: Records gyro compass signal (Synchro / Step) and/or


Ship’s speed log signal as IEC61162-1 sentence formatter
(2) Performance:
a) Signal input: Synchro signal for Gyro compass
Ratio: 360X, 180X, 90X, 36X, 1X
Primary voltage: AC50 – 115V, 50/60Hz
Secondary voltage: AC20 – 90V, 50/60Hz
Step signal for Gyro compass
Ratio: 360X, 180X, 90X, 36X, 1X
Voltage: DC24V / 35V / 50V / 70V
Pulse signal for speed log
Pulse number: 200P / 400P / 100P / 160P (Per NM)
Interface: Opto-Isolation / dry contact signal
b) Recoding data: Data type: IEC61162-1
Heading Sentence formatter: HDT
Sip speed Sentence formatter: VBW

2.2.8 Radar switching recording function


The specification of radar switching recording function when connecting two radars is
as follows:

(1) Function:
a) The radar screen in operation is automatically identified and recorded.
Automatic identification can be performed by monitoring the operation conditions
of the scanners, which can be judged by the original sentences conforming to
IEC61162 outputted from JRC radars.

b)Switching recording function is available only when JRC radars are connected.
The radars that have this switching recording function are the current models
(JMA-5300, JMA-9900, JMA-900M) or new. The older models do not work as
such.

(2) Performance:
Radar switching recording function supports for connecting two non-JRC radars
( refer to b) and c) below ). However, for non-JRC radars, we do not recommend

33
2. Specification

using switching recording function because automatic identification of the


working radar is not functional under the normal operation conditions.
For using switching recording function in the case of non-JRC radars, read the
following specification for proper recording of the working radar images.

a) Current JRC radars (JMA-5300, JMA-9900, JMA-900M)


Operation conditions of scanners are monitored by the sentences conforming
to IEC61162 outputted from X-band radars. When the scanner of X-band
radar is in operation, the radar image connecting to CH1 will be recorded.
When the scanner of X-band radar is not in operation, the radar image
connecting to CH2 will be recorded.

b) Switching SW connection
Recording modes can be selected by connecting the switching SW of the
following specification to the dry contact input (PI_1 and PI_2 of TB406) of
RCU.
¾ AUTO mode: Images of CH to which the synchronized signals
are outputted are automatically selected and
recorded. If the synchronized signals are
outputted from both CH1 and CH2, CH1
overrides. Signal from CH2 is discarded.

¾ CH1 recording mode: Images of CH1 are recorded.


If no images are inputted to CH1, the image
data will not be recorded.

¾ CH2 recording mode: Images of CH2 are recorded.


If no images are inputted to CH2, the image
data will not be recorded.

PI_1(TB406) PI_ 2(TB406) RADAR Recording Mode


OPEN OPEN AUTO
OPEN CLOSE CH1 record
CLOSE OPEN CH2 record

In AUTO mode, the objective radar images will be recorded if the


power of nonoperational radar is turned off. If the nonoperational
radar is set standby, outputting radar images is not stopped and
therefore, only the X-band radar screen without any echoes will be
recorded.

c) Continuous AUTO mode


When the switching SW is not connected and two radars are connected,
images will be recorded continuously by AUTO mode.

34
2. Specification

2.3 Operation Panel Unit: OPU (NCG-169)

(1) Function: Visible indication and audible alarm for VDR system alarm
in the Wheelhouse
Display of the cause of an error
Input of Heading initial value
(2) Performance:
a) Type: Flush mount type or Wall mount type
b) Power supply: Supplied from the RCU NDV-1800
c) Indication: LED lighting for alarm indication
4 digit LED for error code indication
Buzzer (mutable by ACK switch)
d) Operation: Alarm acknowledgement
Dimmer of LED
(3) NSK operation: (Optional NSK interface board is needed in the RCU.)
a) Operation Entry of the initial value of heading
b) Indication Heading value indication
(4) Environmental condition:
a) Operating temperature: -15 deg. to +55 deg. (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(5) General specification
a) Dimensions: 145(w) x 50(d) x 165(h) mm
b) Mass: 0.3kg
c) Color: N4 semi-gloss texture

2.4 Microphone Unit (NVT-161)

(1) Function: Acquisition of W/H conversation, Alarms and sounds etc.


in W/H
(2) Performance:
a) Type: Ceiling mount type, wall mount type
b) Device: Electoret condenser microphone
c) Directivity: Hemispherically omnidirectional
d) Receiving range: 2.5m of radius
e) Power supply: Phantom powered by 12VDC
f) Test device: Built-in speaker for audio acquisition test
(3) Environmental condition:
a) Operating temperature: -15°C to +55°C (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(4) General specification
a) Dimensions: 110(w) x 44.5(d) x 160(h) mm
b) Mass: 0.2kg
c) Color: N4 semi-gloss texture

35
2. Specification

2.5 Connection Box (NQE-3163)

(1) Function: Waterproofed type junction box which connects RCU with
a PCU.
(2) Performance:
a) Connection device: Built-in terminal blocks
(3) Environmental condition:
a) Operating temperature: -25 deg. to +55 deg. (IEC 60945 exposed type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
d) Waterproof grade: IPx6
(4) General specification
a) Dimensions: 170(w) x 176(d) x 87(h) mm
b) Mass: 1.3kg
c) Color: 7.5BG 7/2

2.6 Waterproof Microphone Unit (NVT-162)

(1) Function: Acquisition of wing conversation etc.


(2) Performance:
a) Type: Wall mount type
b) Device: Electoret condenser microphone
c) Directivity: Hemispherically omnidirectional
d) Receiving range: 2.5m of radius
e) Power supply: Phantom powered by 12VDC
f) Test device: Built-in speaker for audio acquisition test
(3) Environmental condition:
a) Operating temperature: -25°C to +55°C (IEC 60945 exposed type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
d) Waterproof grade: IPx6
(4) General specification
a) Dimensions: 126(w) x 93(d) x 110(h) mm
b) Mass: 1.2kg
c) Color: N7 semi-gloss

2.7 Digital Signal Converter (NCT-72) 64CH -Option-

(1) Function: Acquisition of alarms or status condition via dry contact


closure.
(2) Performance:
a) Dry contact Input port: Dry (voltage free) contact closure
Max. 64 port

36
2. Specification

b) Contact closure interface:


1) Driving power supply: +12VDC
2) Status: Normal open / Normal close
c) Communication port To the NDV-1800 RCU
d) Data output interface Data type: IEC61162-1
(3) Optional Analog interface: (Optional Analog signal converting board CEF-60 is needed
in DSC NCT-63.)
a) Analog signal Input port: Max. 8 port
b) Signal input:
1) Voltage: +/-500mV, +/-5V, +/-10V
2) Current: +/-20mA
c) Communication port Same port as dry contact signals
d) Data output interface Data type: IEC61162-1
Analog Sentence formatter: XDR
(4) Environmental condition:
a) Operating temperature: -15 deg. to +55 deg. (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(5) General specification
a) Power voltage: 100 - 120Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
b) Power consumption: 25VA
c) Dimensions: 300(w) x 130(d) x 420(h) mm
d) Mass: 5kg
e) Color: N7 semi-gloss

2.8 Digital Signal Converter (NCT-63) 16CH -Option-

(1) Function: Acquisition of alarms or status condition via dry contact


closure.
(2) Performance:
a) Dry contact Input port: Dry (voltage free) contact closure
Max. 16 port
b) Contact closure interface:
1) Driving power supply: +12VDC
2) Status: Normal Close / Normal open
c) Communication port To the NDV-1800 RCU
d) Data output interface Data type: IEC61162-1
(3) Optional Analog interface: (Optional Analog signal converting board CEF-60 is
needed.)
a) Analog signal Input port: Max. 8 port

b) Signal input:
1) Voltage: +/-500mV +/-5V +/-10V
2) Current: +/-20mA
c) Communication port Same port as dry contact signals
d) Data output interface Data type: IEC61162-1
Analog Sentence formatter: XDR

37
2. Specification

(4) Environmental condition:


a) Operating temperature: -15 deg. to +55 deg. (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(5) General specification
a) Power voltage: 100 - 120Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
b) Power consumption: 25VA
c) Dimensions: 300(w) x 130(d) x 230(h) mm
d) Mass: 2.9kg
e) Color: N7 semi-gloss

2.9 Radar Interface Unit (NWP-46) -Option-

(1) Function: The NWP-46 is required when a high resolution (UXGA)


radar display is connected to the VDR.
The NWP-46 is an option unit in order to install a FGB
near the radar, because high resolution RGB signals can
not be extended to the VDR,
The Frame Grabber Board (FGB) in the NWP-46 is moved
from the RCU.
(2) Performance:
a) Basic performance: The same as the Radar image input specification of the
RCU.
b) Communication port To the NDV-1800 RCU via Ethernet
(3) Environmental condition:
a) Operating temperature: -15 deg. to +55 deg. (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(4) General specification
a) Power voltage: 100 - 120Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240Vac +/- 10% 1-phase 50/60Hz (IEC 60945)
b) Power consumption: 10VA
c) Dimensions: 255(w) x 160(d) x 72(h) mm
d) Mass: 1.5kg
e) Color: N4 semi-gloss

38
2. Specification

2.10 General Environmental Condition of Use

2.10.1 Condition of Use

a) Vessels required to carry VDR:

Mercantile vessels of 3,000G/T or more that are engaged in


international voyage
Passenger vessels of 150G/T or more that are engaged in
international voyage

b) Unit installation locations:

1) The Protective Capsule Unit: External deck above bridge


2) The Connection Box: External deck above bridge
3) The Recording Control Unit: Bridge (or electric room)
4) The Operation Panel Unit: Navigation space in the Bridge
5) The Microphone Unit: Ceiling or bulkhead
6) The Waterproof Microphone Unit: Wings
7) The Digital Signal Converter: Bridge (or electric room)
8) The Radar Interface Unit: near the Radar

c) Installation methods:

1) The Protective Capsule Unit: Mounted on the deck


2) The Connection Box: Mounted on the deck
3) The Recording Control Unit: Hung on the bulkhead
4) The Operation Panel Unit: Hung on the bulkhead or flash
mount on the Console
5) The Microphone Unit: Flash mount on the Ceiling or hung
on the bulkhead
6) The Waterproof Microphone Unit: Hung on the bulkhead
7) The Digital Signal Converter: Hung on the bulkhead
8) The Radar Interface Unit: Mounted on the Radar

2.10.2 Power Supply Environment Conditions

a) AC power supply input range:

1) AC100/110/115/120V ±10%
2) AC200/220/240V ±10%

b) AC power supply frequency fluctuation range:

1) 50Hz ±5%
2) 60Hz ±5%

39
2. Specification

2.10.3 Environmental Condition

a) Exposed type equipment


(Protective Capsule Unit, Waterproof Microphone Unit)
1) Operation temperature range: -25°C to +55°C
2) Storage temperature: -25°C to +70°C
3) Temperature and humidity: +40°C, 93%
4) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
b) Protected type equipment
(Recording Control Unit, Operation Panel Unit, Microphone Unit, Option Unit)
1) Operation temperature range: -15°C to +55°C
2) Temperature and humidity: +40°C, 93%
3) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G

40
3. Maintenance and Inspection

WARNING
Do not attempt checking or repairs on the internal part of the equipment by
yourself.
Checking or repairs by anyone other than our professional maintainer may result
in a fire or an electric shock.
Ask for checking or repairs of the inside of the equipment to the Sales
Department, the nearest branch company, a branch office, a sales office, or any
agent of Japan Radio Co., Ltd.

CAUTION
Do not use organic solvent such as thinner and benzine to clean the surface.
These agents damage the surface coating.
Be sure to remove dirt and dust, if any, from the surface and wipe it with a clean
dry cloth.

3.1 Daily Maintenance

The life of the equipment depends greatly on the quality of maintenance. To keep the
JCY-1800 in the best operating condition, perform inspections of the equipment regularly.
By the inspection, problems can be identified before they develop into major malfunctions.

3.1.1 Cleaning

CAUTION
If the equipment is splashed with seawater or fresh water, wipe it dry
immediately. Ignoring the caution may result in failures or operational
malfunctions.

To remove stains from the equipment, gently wipe it with a soft cloth lightly impregnated
with neutral detergent.

3.1.2 Check of the expiry date of the battery

Check the expiry date of the RCU battery and the underwater acoustic beacon that is
fixed above the capsule.
If the expiration is approaching, contact the Sales Department, the nearest branch
company, branch office, sales office, or any agent of Japan Radio Co., Ltd.

41
3. Maintenance and Inspection

3.2 Periodic Inspection

Periodic internal check is recommended on the equipment and on its connections with the
PSU and the other devices. This check is charged.
Annual maintenance is requested by the Ship Class, please contact the Sales Department,
the nearest branch company, a branch office, a sales office, or any agent of Japan Radio
Co., Ltd.

42
3. Maintenance and Inspection

3.3 Troubleshooting

If the JCY-1800 does not function correctly, check the equipment referring to the list shown
below. Take the action recommended in the list. If the malfunction persists, contact the
Sales Department, the nearest branch company, branch office, sales office, or any agent of
Japan Radio Co., Ltd.

3.3.1 The Recording Control Unit (NDV-1800)

(1) List of approaches for troubles of The PSU (NBL-327)

Symptom Causes Actions to be taken


POWER LED fails to No power is supplied from the Check the switchboard.
light. switchboard.
POWER switch is not on. Turn on the POWER switch.

The AC-line fuse is blown. Check the AC-line fuse in the PSU.
If it is blown, replace it with a
spare.
Fault in the PSU Contact us.

The BATTERY OP. No power is supplied from the Check the switchboard.
LED lights up. switchboard.

The fuse for the AC power source is Check the fuse for the AC power
blown. source and, if it is blown, replace it
with a spare.
BATTERY The battery cable is disconnected. Contact us.
ABNORMAL LED
lights up. The fuse for the battery is blown. Contact us.

The battery is deteriorated. Check the expiry date of the battery.


If the battery has expired, contact
us.
FAN ABNORMAL The fan is not working. Contact us.
LED lights up.

43
3. Maintenance and Inspection

(2) List of approaches for troubles of The Data Processor Unit (NDL-46)

Symptom Causes Actions to be taken


REC LED fails to The RCU is off. Check the switchboard.
light. The power is not supplied to the PCU. Turn on the PSU.

The recording of data into the PCU has Press the REC START switch on the
been stopped manually. MCB to restart the recording of
data.
Faulty wiring between the RCU and Check the hookups in the
the PCU Connection Box.
Fault in the RCU Reboot the RCU and see if it works
Fault in the PCU normally. If it doesn’t, contact us.

CARD LED fails to The CARD STOP switch is left on. Press the CF CARD EJECT BUTTON
light up. and remove the card from the MCB.
Then put it back again.
No CF CARD is loaded. Insert a CF CARD into the CARD
slot of the MCB.

Fault in the RCU Reboot the RCU and see if it works


normally. If it does not work,
contact us.
MEDIA LED blinks. Fault in the CF CARD Press the CF CARD EJECT BUTTON
and remove it from the MCB. Then
put it back again.

Fault in the RCU Reboot the RCU and see if it works


normally. If it does not work,
contact us.

No CF CARD is loaded. Insert a CF CARD into the CARD


slot of the MCB.

CARD LED and The recorded data on CF CARD are It is normal operation since the
MEDIA LED flashes. protected against overwriting data. recorded data in accident are protected
against unauthorized or inadvertent
overwriting.
In the following cases, release the
protection of CF CRAD to start
recording data onto CF CARD.
• It becomes unnecessary to preserve
recorded data in accident after
transferring preserved data to relevant
authorities.
• The recorded data in CF CARD have
been protected by mistake.
Press REC START switch on MCB
until CARD LED lights up (approx.
10 seconds).

44
3. Maintenance and Inspection

3.3.2 The Operation Panel Unit (NCG-169)

All failures of the RCU are indicated by the OPU as an error code.

Symptom Causes Actions to be taken


All LEDs blink and The software of the RCU freezes. Reboot the RCU.
the alarm buzzer
sounds. Faulty wiring between the RCU and Check the wiring between the RCU
the OPU. and the OPU.

RECORDING LED The RCU is off. Check the switchboard.


fails to light. The power is not supplied to the PCU. Turn on the PSU.
Stop manually the recording of data Press the REC START switch on the
onto the PCU. MCB in the RCU and restart the
recording of data.

Faulty wiring between the RCU and Check the hookups in the
the PCU Connection Box.

Fault in the RCU Reboot the RCU and see if it works


Fault in the PCU normally. If it doesn’t, contact us.

ERROR CODE: Initial value of HEADING is not Enter the initial value of HEADING
“01__” lights up. registered yet.

ERROR CODE: The recorded data on CF CARD are It is normal operation since the
“03__” lights up. protected against overwriting data. recorded data in accident are protected
against unauthorized or inadvertent
overwriting.
In the following cases, release the
protection of CF CRAD to start
recording data onto CF CARD.
• It becomes unnecessary to preserve
recorded data in accident after
transferring preserved data to relevant
authorities.
• The recorded data in CF CARD have
been protected by mistake.
Press REC START switch on MCB
until CARD LED lights up (approx.
10 seconds).
ERROR CODE: The CARD STOP switch is left on. Press the CF CARD EJECT BUTTON
“31__” lights up. and remove it from the MCB. Then
put it back again.
No CF CARD is loaded. Insert a CF CARD into the CARD
slot of the MCB.
Fault in the RCU Reboot the RCU and see if it works
normally. If it doesn’t, contact us.

45
3. Maintenance and Inspection

Symptom Causes Actions to be taken


ERROR CODE: Fault in the CF CARD Press the CF CARD EJECT BUTTON
“32__” lights up. and remove the card from the MCB.
Then put it back again.

Fault in the RCU Reboot the RCU and see if it works


normally. If it doesn’t, contact us.

ERROR CODE: Mismatching in the information Press and hold the REC START
“00__” lights up. between the RCU and the PCU. switch for ten seconds.

Faulty wiring between the RCU and Check the hookups in the
the PCU. Connection Box.

Fault in the RCU Reboot the RCU and see if it works


Fault in the PCU normally. If it doesn’t, contact us.

ERROR CODE: Malfunction in PCU Reboot RCU, and see if the symptom
“20__” lights up. persists. If so, contact our office.

ERROR CODE: Fault in recording the data in the PCU The BER ERROR can occur
“21__” lights up. temporarily.
The error is canceled in less than 2
days of itself.
If the error is not canceled after 2
days, contact us.

ERROR CODE: Faulty wiring between RCU and PCU Check hookups in Connection Box.
“23__” lights up.

Malfunction in RCU Reboot RCU, and see if the symptom


Malfunction in PCU persists. If so, contact our office.

ERROR CODE: Fault in sensors Check the sensor equipment shown


“60**” lights up. by error code.

Faulty wiring between the RCU and Check the wiring between the RCU
the sensors and the sensors.

Fault in the RCU Reboot the RCU. See if the symptom


persists. If so, contact us.

ERROR CODE: Fault on setting up the MCB Reboot the RCU, and see if the
“61**” lights up. symptom persists. If so, contact us.

ERROR CODE: Fault in the ARB Check the wiring between the MIC
“5*__” lights up. Fault in the MIC and the RCU.

Alarm was raised due to a large noise. Reboot the RCU in noise-free
environment.

46
3. Maintenance and Inspection

Symptom Causes Actions to be taken


ERROR CODE: Power failure Check the power supply in the RCU.
“10__” lights up.
No power is supplied from the Check the switchboard.
switchboard.

The fuse for the AC power source is Check the fuse for the AC power
blown. source and, if it is blown, replace it
with a spare.

ERROR CODE: The fan of PSU is not working. Contact us.


“11__” lights up.

ERROR CODE: Fault in the MCB Reboot the RCU, and see if the
“30__” / “35__” / symptom persists. If so, contact us.
“36__” / “37__” /
“38__” light up.

ERROR CODE: GPS is faulty or setting error on the Check the GPS.
“33__” lights up. MCB If the GPS is error-free, contact us.

ERROR CODE: An internal battery for a Real Time Contact us for exchanging the
“34__” lights up. Clock IC has run out of the life. battery.

ERROR CODE: Fault in the ARB Reboot the RCU, and see if the
“40__”/“41__”/ symptom persists or not. If yes,
“42__” lights up. contact us.

ERROR CODE: Fault in RGB signals from a RADAR Check the RADAR.
“70__” / “71__” 70__: CH1 If an image is displayed on the
lights up. screen, check the wiring between
71__: CH2
the RADAR and the RCU.

ERROR CODE: Faulty wiring between the FGB and Check the wiring between the FGB
“72__” lights up. the MCB and the MCB.

Fault in the FGB Reboot the RCU, and see if the


Fault in the MCB symptom persists or not. If yes,
contact us.

ERROR CODE: Fault on setting up the FGB Reboot the RCU, and see if the
“73__” / “76__” symptom persists or not. If yes,
lights up. contact us.

ERROR CODE: Fault in the FGB Reboot the RCU, and see if the
“74__” lights up. symptom persists or not. If yes,
contact us.
ERROR CODE: The fan of NWP-46 is out of order. Contact us.
“75__” lights up.

ERROR CODE: Faulty wiring between the PSU and Reboot the RCU, and see if the
“12__” lights up. the MCB symptom persists or not. If yes,
contact us.

47
3. Maintenance and Inspection

Symptom Causes Actions to be taken


ERROR CODE: Faulty wiring between the RMB and Check the wiring between the RMB
“80__” lights up. the MCB and the MCB.

Fault in the RMB Reboot the RCU, and see if the


Fault in the MCB symptom persists or not. If yes,
contact us.

ERROR CODE: Fault in the RMB Reboot the RCU, and see if the
“81__” lights up. symptom persists or not. If yes,
contact us.

48
4. After-sales Service

4.1 To request the service

If you suppose the product may be out of order, read section 3 and take the action
recommended thereof.
If the equipment will still be faulty, you are advised to stop the operation and contact
the Sales Department, the nearest branch company, branch office, sales office, or any
agent of Japan Radio Co., Ltd. immediately.

1) Repair within the warranty period


If any failure occurs on the product during the normal operation in accordance
with the instruction manual, the dealer or JRC will carry out the repair free of
charge. In case the trouble was caused by user’s misuse, faulty operation,
negligence or force ma-jeure such as natural disaster and fire, the repair shall
be charged.

2) Repair after the warranty period


The service after the warranty period is Not Free. It is charged.

3) Let us know the Helpful information for service engineer


a) Product name, model, manufacturing date and serial number
b) Trouble conditions (Go into details as much as possible. Refer to “VDR
Failure Check List” in the next page)
c) Name of shipping company/organization, address and telephone number

For further details of after-sales service, contact the JRC Offices in the list at the end
of this manual.

49
4. After-sales Service

VDR Failure Check List

When placing an order for repair of the product, you are kindly requested to check “Yes”
“No” boxes on the list shown below and send the sheet back to our office.
If there is any unclear item, contact the vessel on which the product is installed, and make
the uncertainly clear.

Ship Name: Phone: Fax:


Model: Date of Manufacture: Serial Number:

1) Read the following check items in order and check Yes or No by “√”. If you are not sure
to give answer, explain how the fault arose in “Others” of item 7.
2) If item (1) or (2) is Yes, check the fuse of RCU and the Switch Board for VDR.

No. Check Items Results


Yes No
(1) The Power LED on the OPU is off.
(2) The Power LED on the OPU is blinking.
(3) The Recording LED on the OPU is off.
(4) The Alarm LED on the OPU is on.
(5) The OPU is not operative.
(6) The Error Code LEDs on the OPU displays any error code.
(7) If item (6) is marked as Yes, fill at following space all error code.

Others

50
4. After-sales Service

4.2 Disposal of unit

When disposing of this unit, abide by the local laws and regulations. Contact the
Sales Department, the nearest branch company, branch office, sales office, or any
agent of Japan Radio Co., Ltd. and ask them to replace it without discarding the
battery.

4.3 Disposal of used battery

Never short-circuit the + and – pins. Never disassemble, modify, destroy, throw
into fire, heat, use with non-specified applications and use after the expiry date.
Above acts may cause leakage of fluid, generation of heat, fire, explosion,
destruction, or injury by heat.

The RCU (NDV-1800) of this equipment incorporates a battery.


Used batteries are to be recycled. Regarding the replacement and recycle, contact
the Sales Department, the nearest branch company, branch office, sales office, or
any agent of Japan Radio Co., Ltd. and ask them the replacement and recycle.

The MCB (CDJ-2304), the RMB (CDK-287) and the Underwater Acoustic Beacon on
the PCU of this equipment incorporate a lithium battery.
Used batteries are to be recycled. Regarding the replacement and recycle, contact
the Sales Department, the nearest branch company, branch office, sales office, or
any agent of Japan Radio Co., Ltd. and ask them the replacement and recycle.

51
4. After-sales Service

This page left blank intentionally

52
5. Outside Drawings

5.1 Recording Control Unit: NDV-1800

The Outside Drawing of Recording Control Unit

53
5. Outside Drawings

5.2 Operation Panel unit: NCG-169

NCG-169 VDR OPERATION PANEL

The Outside Drawing of Operation Panel Unit

54
5. Outside Drawings

5.3 Protective Capsule Unit: NDH-316A / 316

● NDH-316A

VOYAGE DATA RECORDER TA RECORDER


DO NOT OPEN T OPEN
REPORT TO AUTHORITIES AUTHORITIES

The Outside Drawing of Protective Capsule Unit (NDH-316A)

55
5. Outside Drawings

● NDH-316

VOYAGE DATA RECORDER TA RECORDER


DO NOT OPEN T OPEN
REPORT TO AUTHORITIES AUTHORITIES

L3

The Outside Drawing of Protective Capsule Unit (NDH-316)

56
5. Outside Drawings

5.4 Connection Box: NQE-3163

The Outside Drawing of Connection Box

57
5. Outside Drawings

5.5 Microphone Unit: NVT-161

The Outside Drawing of Microphone Unit

58
5. Outside Drawings

5.6 Waterproof Microphone Unit: NVT-162

Option

The Outside Drawing of Waterproof Microphone Unit

59
5. Outside Drawings

5.7 Digital Signal Converter: NCT-72 (64ch)

Option

The Outside Drawing of Digital Signal Converter (64ch)

60
5. Outside Drawings

5.8 Digital Signal Converter: NCT-63 (16ch)

Option

The Outside Drawing of Digital Signal Converter (16ch)

61
5. Outside Drawings

5.9 Radar Interface Unit: NWP-46

Option

The Outside Drawing of Radar Interface Unit

62
5. Outside Drawings

This page left blank intentionally

63
65
The Block Diagram of Recording Control Unit
(2) (4) (4) (3) (3)
J305 J304 J303 J310 J309
Backup TEST Batt. line AC line FAN
SW SW SW
Sensor Control
BATT Thrm. UPS DC Power out
J306 J307 J308
(2) (8) (10)
(4) (2)
J405 J404
TB402 7JTJD0031 TB401 7JTJD0030
TB405 7JTJD0033 TB404 7JTJD0033
(2) (8) (10)
J403 J402 J401
TB403
TB406 7JTJD0036
7JTJD0035
J409 J408 (64) J407 (90) J406 (90)
(8)
J801 J701 J501
RECORDING
(8) RESTART
J1001 REC STOP
CF CARD
MEDIA
BACKUP STOP
J504
D-SUB15 D-SUB15
JRC-LAN VDR-LAN
RGB2 Input RGB1 Input J702 J703 J502 J503
CF
J804 J803 J602
(50)
(15) (15)
CF Card
W110 LAN cable 7ZCJD0284
W109 LAN cable 7ZCJD0284
(50)
J901
(4)
J1101
NDV-1800 6.1 Recording Control Unit
6. Block Diagrams
6. Block Diagrams

6.2 Operation Panel Unit NCG-169

J1101

The Block Diagram of Operation Panel Unit

66
6.3 Microphone Unit
NVT-161

TB1
MIC CN1 MIC+
+ RED 1 TTYCS-1Q
1 MIC-
- BLUE MIC AMP Board 2
2 SHIELD
+ YELLOW MIC-P2(R1) 3 RCU
3 SP+

67
- WHITE 4
4 SP-
5
SPEAKER

TB1:WAGO 255 Series

The Block Diagram of Microphone Unit


Microphone Unit (NVT-161)Connection Diagram
6. Block Diagrams
6. Block Diagrams

6.4 Waterproof Microphone Unit NVT-162

Option

The Block Diagram of Waterproof Microphone Unit

68
TB1 TB2 TB3 TB4
1 CH01 CH09 32 CH17 CH25 1 CH33 CH41 32 CH49 CH57
CH02 CH10 CH18 CH26 CH34 CH42 CH50 CH58
6.5

CH03 CH11 CH19 CH27 CH35 CH43 CH51 CH59

J1
CH04 CH12 CH20 CH28 CH36 CH44 CH52 CH60 Dry Contact in

P51
CH05 CH13 CH21 CH29 CH37 CH45 CH53 CH61
x64ch
W102
CH06 CH14 CH22 CH30 CH38 CH46 CH54 CH62
7ZCJD0286
Option

AC/DC Power Supply Unit CH07 CH15 CH23 CH31 CH39 CH47 CH55 CH63
AES30-12 CH08 CH16 CH24 CH32
32 1 CH40 CH48 32 CH56 CH64 1

J202
Dry Contact Input Board
P1
CQD-2081

J2

W101
CN1
7ZCJD0189A
POWER IN
AC85~132V or
AC170~265V J102

U
FUSE
AC Filter Board RCU

V
TB101
Digital Signal Converter (CH64)

NMEA data output


CBJ-147 1

69
Tx+
Dry Contact Control Board

E
Tx-
CDJ-2333 GND
Rx+
O I

SW
J104 5 Rx-

TB1
NCT-72

J103

The Block Diagram of Digital Signal Converter


Digital Signal Convertor 64CH (NCT-72)
Connection Diagram
6. Block Diagrams
TB1 TB2 TB3 TB4
1 CH01 CH09 32 CH17 CH25 1 CH33 CH41 32 CH49 CH57
CH02 CH10 CH18 CH26 CH34 CH42 CH50 CH58

CH03 CH11 CH19 CH27 CH35 CH43 CH51 CH59

J1
CH04 CH12 CH20 CH28 CH36 CH44 CH52 CH60 Dry Contact in

P51
W102 CH05 CH13 CH21 CH29 CH37 CH45 CH53 CH61
x64ch
CH06 CH14 CH22 CH30 CH38 CH46 CH54 CH62
7ZCJD0286
AC/DC Power Supply Unit
CH07 CH15 CH23 CH31 CH39 CH47 CH55 CH63
AES30-12 CH08 CH16 CH24 CH32 1 CH40 CH48 32 CH56 CH64 1
32
6. Block Diagrams

J202
Dry Contact Input Board
P1
CQD-2081

J2

W105
W101
CN1 7ZCJD0238
POWER IN 7ZCJD0189A
AC85~132V or
AC170~265V
J102

U
FUSE
AC Filter Board RCU

V
TB101 NMEA data output
CBJ-147 1

70
Tx+
Dry Contact Control Board

E
Tx-
CDJ-2333 GND
Rx+
O I

SW
J104 5 Rx-

TB1
J103

W104
7ZCJD0263

J303

TB301 TB302 Analog data in


1 CH0+ 1 CH4+ x8ch
CH0- CH4-
CH1+ CH5+
A/D Convert Board CH1- CH5-
CH2+ CH6+
J301

CEF-60 CH2- CH6-

The Block Diagram of Digital Signal Converter + Optional A/D board


CH3+ CH7+
8 CH3- 8 CH7-
J302

Digital Signal Convertor 64CH (NCT-72) + Option: A/D Board 8CH


Connection Diagram
TB1
1 CH01 CH09

CH02 CH10
6.6

CH03 CH11 Dry Contact in


CH04 CH12 x16ch

P51
J201
W102 CH05 CH13

7ZCJD0286 CH06 CH14


Option

AC/DC Power Supply Unit CH07 CH15


AES15-12 CH08 CH16 32

Dry Contact Input Board

J202
P1 CQD-2012

J2

W101
CN1
POWER IN 7ZCJD0189A
AC85~132V or
AC170~265V
J102

U
FUSE RCU
AC Filter Board TB101 NMEA data output
Digital Signal Converter (CH16)

V
1 Tx+
CBJ-147

71
Dry Contact Control Board Tx-

E
GND
CDJ-2333
O I Rx+
Rx-

SW
J104 5

TB1
NCT-63

J103

The Block Diagram of Digital Signal Converter


Digital Signal Convertor 16CH (NCT-63)
Connection Diagram
6. Block Diagrams
TB1
1 CH01 CH09

CH02 CH10

CH03 CH11 Dry Contact in


CH04 CH12 x16ch

P51
J201
CH05 CH13
W102
7ZCJD0286 CH06 CH14
AC/DC Power Supply Unit CH07 CH15
AES-30-12 CH08 CH16 32
6. Block Diagrams

Dry Contact Input Board

J202
P1 CQD-2012

J2

W105 W101
CN1
7ZCJD0238 7ZCJD0189A
POWER IN
AC85~132V or
J102

U
AC170~265V FUSE
RCU
AC Filter Board TB101 NMEA data output

V
CBJ-147 1 Tx+

72
Dry Contact Control Board Tx-

E
CDJ-2333 GND
O I Rx+

SW
J104 5 Rx-

TB1
J103

W104
7ZCJD0263

J303

TB301 TB302 Analog data in


1 CH0+ 1 CH4+ x8ch
CH0- CH4-
CH1+ CH5+
A/D Convert Board CH1- CH5-
CH2+ CH6+
J301

CEF-60 CH2- CH6-

The Block Diagram of Digital Signal Converter + Optional A/D board


CH3+ CH7+
8 CH3- 8 CH7-
J302

Digital Signal Convertor 16CH (NCT-63) + Option: A/D Board 8CH


Connection Diagram
6. Block Diagrams

6.7 Radar Interface Unit NWP-46

Option

The Block Diagram of Radar Interface Unit

73
JCY-1800
VOYAGE DATA RECORDER

INSTRUCTION
MANUAL

For further information,contact:

Not use the asbestos

URL http://www.jrc.co.jp
Marine Service Department
Telephone : +81-3-3492-1305
Facsimile : +81-3-3779-1420
e-mail : tmsc@jrc.co.jp
AMSTERDAM Branch
Telephone : +31-20-658-0750
Facsimile : +31-20-658-0755
e-mail : service@jrcams.nl
SEATTLE Branch
Telephone : +1-206-654-5644
Facsimile : +1-206-654-7030
e-mail : service@jrcamerica.com
CODE No.7ZPJD0385
No.7ZPJD0385B 01ETM ISO 9001, ISO 14001 Certified
MAY.. 2008 Edition 1
MAY JRC Printed in Japan
JCY-1800
航海データ記録装置
IMO MSC.214(81) 対応

取扱説明書

Not use the asbestos

JRCウェブサイト http://www.jrc.co.jp
マリンサービス部
〒141-0032 東京都品川区大崎1丁目18番7号
電話番号 (03)3492-1305
FAX番号 (03)3779-1420
e-mail tmsc@jrc.co.jp
アムステルダム支店
電話番号 +31-(0)20-658-0750
FAX番号 +31-(0)20-658-0755
e-mail service@jrcams.nl
シアトル支店
電話番号 +1-(0)206-654-5644
FAX番号 +1-(0)206-654-7030
e-mail service@jrcamerica.com
コード No.7ZPJD0386B 01JTM ISO9001, ISO14001 認証取得
2008 年 5 月作成 1版 JRC
はじめに

このたびは、JRC JCY-1800 航海データ記録装置(VDR:Voyage Data Recorder)

をお買いあげいただきまして、誠にありがとうございます。

本装置は、船舶事故の原因究明と予防を目的とします。国際規格で要求され

ている船舶の運航や船体運動に関わるデータを記録します。

● お使いになる前に、この取扱説明書をよくお読みのうえ、正しくお使いく

ださい。

● 取扱説明書は必要な時に参照できるよう大切に保管してください。

● 万一、ご使用中にわからないことや不具合が生じた時にお役立てください。

VDRは、海難事故発生時の事故原因を解析するために船体情報、操船情報を記録している
装置です。
万が一、事故が発生した場合には、その時の記録データを保全する義務があります。

事故発生時には、本書の1.4.4項「事故発生時の対応」の手順に従い、記録データの保全に
努めていただく必要がありますので、対処手順を十分理解した上で運用していただけます
ようお願い致します。

ご注意 VDR は 12 時間以上経過した古いデータを消去して新しいデータを上書きしま


す。事故発生後、適切な処置を行いませんと、12 時間後には事故当時の記録デ
ータが消えてしまいます。

i
はじめに

本装置はIMO(International Maritime Organization:国際海事機関)の規格改訂


MSC.214(81)に対応しております。

* MSC.214(81): 事故調査官による記録データの回収、解析が容易に出来るよう、
下記の機能の追加が要求されています。

・ 記録データのダウンロードソフト、変換ソフトの標準装備
・ 船上での2.5時間以内の記録データ回収
・ 事故時の記録データの不注意による上書き防止

銘板下の下記シールがIMO MSC.214(81)対応を示しています。

Conforms to IMO MSC. 214(81).

Please preserve the recording data of the VOYAGE DATA RECORDER ( VDR / S-VDR )

Press the CARD STOP SWITCH on the internal Main Control Board for about 10
seconds to preserve the recorded data in the CF CARD after an incident.
The CARD LED ○ and the MEDIA LED ○ will blink for preserving the recorded
data.

Please contact and follow your ships Authorities instructions.


CAUTION If the Authority instructs you to stop recording further data and proceed to the
next port for later downloading of data by an Authority Inspector, please turn off
the power to the VDR/S-VDR at the power switchboard to preserve the recording.

Note: If the unit is not switched off, the recorded data of the incident will be
automatically overwritten after 12 hours further recording and it is required that
ships preserve the recorded data of the incident by International rules and regulations.

ii
ご使用のまえに
絵表示について
この取扱説明書および製品への表示では、製品を安全に正しくお使い
いただき、あなたや他の人々への危害や財産への損害を未然に防止す
るために、いろいろな絵表示をしています。その表示と意味は次のよ
うになっています。
内容をよく理解してから本文をお読みください。

危険 この表示を無視して、誤った取扱いをすると、人が死亡または重傷を負
う危険が差し迫って生じることが想定される内容を示しています。

この表示を無視して、誤った取扱いをすると、人が死亡または重傷を負
警告 う可能性が想定される内容を示しています。
この表示を無視して、誤った取扱いをすると、人が傷害を負う可能性が
注意 想定される内容および物的傷害のみの発生が想定される内容を示してい
ます。

絵表示の例

△記号は注意(危険、警告を含む)を促す内容があることを告げるも
のです。
図の中に具体的な注意内容(左図の場合は感電注意)が描かれていま
感電注意 す。

記号は禁止の行為であることを告げるものです。
図の中や近傍に具体的な禁止内容(左図の場合は分解禁止)が描かれ
ています。
分解禁止

●記号は行為を強制したり指示する内容を告げるものです。
図の中に具体的な指示内容(左図の場合は電源プラグをコンセントか
プラグを抜け ら抜け)が描かれています。

警告ラベルについて

本装置には警告ラベルが貼ってあります。
警告ラベルを取り外したり、破損、改変を絶対にしないでください。

iii
ご使用上の注意

禁止事項:バッテリ及びリチウム電池
・ +-端子間のショート
・ 指定された用途以外の使用
・ 分解、改造、破棄
・ 火中投入及び加熱
・ 交換時期を過ぎての使用
漏液、発熱、火災、爆発、破壊、やけどなどの危険があります。

本装置を分解・改造しないでください。
火災・感電・故障の原因となります。

指定された電源電圧以外は使用しないでください。
火災・感電・故障の原因となります。

外部機器との接続ケーブルのコネクタを抜き差しする場合には、必ず電源スイ
ッチを切ってください。
電源スイッチを切らないと火災・感電の原因となります。

電源コードが痛んだら当社の営業部またはお近くの支社・支店・営業所または
当社代理店に交換をご依頼ください。
そのまま使用すると火災・感電の原因となります。

万一、内部に水などが入った場合は、まず本装置の電源スイッチを切り、電源
コードを外してから当社の営業部またはお近くの支社・支店・営業所または当
社代理店にご連絡ください。
そのまま使用すると、火災・感電・故障の原因となります。

iv
ご使用上の注意

お客様による内部の点検・修理は絶対に行わないでください。
専門整備員以外による点検・修理は火災・感電の原因となります。
内部の点検・修理は当社営業部またはお近くの支社・支店・営業所または当社
代理店にご依頼ください。

故障の時は本装置の電源を切ってから当社の営業部またはお近くの支社・支
店・営業所または当社代理店にご連絡ください。
そのまま使用すると、火災・感電の原因となります。

本装置の記録制御機(NDV-1800)にはバッテリが組み込まれています。
バッテリは定期的な交換が必要です。寿命の過ぎたバッテリを使用し続け
ると、火災の原因となります。

お客様によるバッテリの交換は、絶対に行わないでください。
専門整備員以外による交換は、火災・感電・故障の原因となります。
バッテリ交換は当社の営業部またはお近くの支社・支店・営業所または当社
代理店にご依頼ください。

本装置の記録制御機(NDV-1800)にはバッテリが組み込まれています。
バッテリは内部に希硫酸が入っています。バッテリが漏液して皮膚や衣類に
付着した場合には、きれいな水で洗い流してください。また、液が目に入った
時は、すぐにきれいな水で洗った後、医師の治療を受けてください。

本装置の記録制御機(NDV-1800)にはバッテリが組み込まれています。
使用済みのバッテリは、リサイクルします。そのまま廃棄しないでください。
交換の際は、当社の営業部又はお近くの支社・支店・営業所または当社代理
店に連絡ください。

本装置の主制御部(CDJ-2304)、リモートメンテナンス部(CDK-287)および
保護カプセルの水中ビーコンにはリチウム電池を使用しています。
交換の際の使用済みリチウム電池は、そのまま廃棄しないで、当社の営業部又
はお近くの支社・支店・営業所または当社代理店に連絡ください。

本装置を廃棄する時は、廃棄する場所を管轄する地方自治体の条例または規則
に従って処理してください。ただしバッテリ、リチウム電池についてはその
まま廃棄しないで、当社の営業部又はお近くの支社・支店・営業所または当
社代理店に連絡ください。

v
ご使用上の注意

本装置には警告ラベルが貼ってあります。
警告ラベルを取り外したり、破損、改変を絶対にしないでください。

水、湿気、湯気、ほこり、油煙等の多い場所に設置しないでください。
火災・感電・故障の原因となることがあります。

本装置を淡水、海水の付着した手または手袋でふれないでください。
感電・故障の原因となることがあります。

電源コードを外す時は、必ず電源端子を正しく外してください。
電源コードを引っ張るとコードが傷ついて、火災・感電の原因となることがあ
ります。

濡れた手で電源コードの抜き差しをしないでください。
感電の原因となることがあります。

記録制御機のサービスコンセントの形状は、AC100V 用ですが記録制御機の
入力電圧がそのまま出力されています。AC220V が出力されている時に
AC100V の機器を接続しないでください。誤って接続すると故障の原因となる
ことがあります。

FAN ABN. LED が点灯した場合、電源ユニット用空冷ファンが停止しています


ので空冷ファンを交換する必要があります。そのまま継続して使用しますと
故障の原因となることがあります。当社の営業部又はお近くの支社・支店・
営業所または当社代理店に交換をご依頼ください。

海水や淡水が本装置にかかった場合はすぐにふき取ってください。故障、操作
不良の原因となることがあります。

表面を掃除するときは、シンナーやベンジンなどの有機溶剤を使用しないでく
ださい。表面の塗装を痛める原因となります。
表面の掃除はチリ、ゴミを取り除き、清潔な布で乾拭きするようにしてくださ
い。

vi
機器外観

記録制御機 保護カプセル 操作表示器

vii
目次

目 次

はじめに ...............................................................................................................................i
ご使用のまえに................................................................................................................... iii
ご使用上の注意................................................................................................................... iv
機器外観 ............................................................................................................................ vii
略語 .................................................................................................................................... xi
用語 ................................................................................................................................... xii

第1章 操作説明 ................................................................................................................1


1.1 装置の概要 ........................................................................................................................ 1
1.2 装置の構成 ........................................................................................................................ 1
1.2.1 系統図 .................................................................................................................................3
1.3 システムの起動・停止 ...................................................................................................... 4
1.3.1 システムの起動...................................................................................................................4
1.3.2 システムの停止...................................................................................................................6
1.4 操作説明 ............................................................................................................................ 7
1.4.1 保護カプセルへの記録を停止する場合 ...............................................................................7
1.4.2 保護カプセルへの記録を再開する場合 ...............................................................................7
1.4.3 CF カード内のデータをバックアップする場合 ..................................................................7
1.4.4 CF カードの記録データを保全する場合 .............................................................................8
1.4.5 事故発生時の対応(ガイドライン)...................................................................................9
1.4.6 操作表示器(Operation Panel Unit)のブザーを停止する場合 .............................................10
1.5 記録制御機 Recording Control Unit (NDV-1800) .............................................................11
1.5.1 記録制御機 Recording Control Unit (NDV-1800)の各部の名称 .......................................11
1.5.2 電源ユニット (Power Supply Unit) .................................................................................13
1.5.3 データ処理部 (Data Processor Unit)...............................................................................16
1.6 操作表示器 Operation Panel Unit (NCG-169) .................................................................... 20
1.6.1 操作表示器 (NCG-169)の各部の名称 ..............................................................................20
1.6.2 操作表示器の操作方法(通常モード) ............................................................................22
1.6.3 操作表示器の操作方法(NSK モード) ...........................................................................28

viii
目次

第2章 仕様 .....................................................................................................................29
2.1 保護カプセル (Protective Capsule Unit: PCU) NDH-316A/316 ............................... 29
2.2 記録制御機 (Recording Control Unit: RCU) NDV-1800 .............................................. 30
2.2.1 操作表示部 (内部パネル) .................................................................................................30
2.2.2 データ処理部 (Data Processor Unit)................................................................................30
2.2.3 電源ユニット (Power Supply Unit: PSU).........................................................................32
2.2.4 外部インターフェース(External Interface) ..................................................................32
2.2.5 環境条件...........................................................................................................................32
2.2.6 一般仕様...........................................................................................................................33
2.2.7 NSK インターフェース部(オプション)........................................................................33
2.2.8 レーダ切替記録機能.........................................................................................................33
2.3 操作表示器 (Operation Panel unit) NCG-169............................................................... 35
2.4 マイクユニット (Microphone Unit) NVT-161 ............................................................... 35
2.5 防水中継箱 (Connection Box) NQE-3163 .................................................................... 36
2.6 防水マイクユニット (Waterproof Microphone Unit:オプション) NVT-162................ 36
2.7 接点信号入力器 64CH (Digital Signal Converter:オプション) NCT-72 ................... 37
2.8 接点信号入力器 16CH (Digital Signal Converter:オプション) NCT-63 ................... 38
2.9 レーダ I/F ユニット (Radar Interface Unit:オプション) NWP-46 .............................. 39
2.10 使用環境条件................................................................................................................... 39
2.10.1 使用条件.........................................................................................................................39
2.10.2 電源環境条件..................................................................................................................40
2.10.3 環境条件.........................................................................................................................40

第3章 保守点検 ..............................................................................................................41


3.1 日常の保守 ...................................................................................................................... 41
3.1.1 清掃..................................................................................................................................41
3.1.2 電池の有効期限の確認 .....................................................................................................42
3.2 定期点検 .......................................................................................................................... 42
3.3 トラブルシューティング................................................................................................. 43
3.3.1 記録制御機 Recording Control Unit (NDV-1800) .............................................................43
3.3.2 操作表示器 Operation Panel Unit (NCG-169)..................................................................45

第4章 アフターサービス................................................................................................49
4.1 修理を依頼される時 ........................................................................................................ 49
4.2 廃棄について................................................................................................................... 51
4.2.1 本装置の廃棄について .....................................................................................................51
4.2.2 使用済み電池の処置について...........................................................................................51

ix
目次

第5章 外形図..................................................................................................................53
5.1 記録制御機 ( Recording Control Unit: NDV-1800 ) .................................................... 53
5.2 操作表示器 ( Operation Panel Unit:NCG-169 ) .......................................................... 54
5.3 保護カプセル ( Protective Capsule Unit:NDH-316A/316 )....................................... 55
5.4 防水中継箱 ( Connection Box:NQE-3163 ) .................................................................. 57
5.5 マイクユニット ( Microphone Unit:NVT-161 ) ............................................................. 58
5.6 防水マイクユニット ( Waterproof Microphone Unit:NVT-162 ) ................................... 59
5.7 接点信号入力器 64CH ( Digital Signal Converter:NCT-72 ) ......................................... 60
5.8 接点信号入力器 16CH ( Digital Signal Converter:NCT-63 ) ......................................... 61
5.9 レーダ I/F ユニット ( Radar Interface Unit:NWP-46 ).................................................. 62

第6章 系統図..................................................................................................................63
6.1 記録制御機 ( Recording Control Unit ) NDV-1800........................................................ 63
6.2 操作表示器 ( Operation Panel Unit ) NCG-169 ............................................................ 64
6.3 マイクユニット ( Microphone Unit ) NVT-161 ............................................................. 65
6.4 防水マイクユニット ( Waterproof Microphone Unit ) NVT-162 ................................... 66
6.5 接点信号入力器 64CH ( Digital Signal Converter ) NCT-72 ......................................... 67
6.6 接点信号入力器 16CH ( Digital Signal Converter ) NCT-63 ......................................... 69
6.7 レーダ I/F ユニット ( Radar Interface Unit ) NWP-46.................................................. 71

x
略語

略語

VDR: Voyage Data Recorder (航海データ記録装置)


IMO: International Maritime Organization (国際海事機関)
IEC: International Electrotechnical Commission (国際電気標準会)
PCU: Protective Capsule Unit (保護カプセル)
RCU: Recording Control Unit (記録制御機)
CF CARD: Compact Flash Card (CF カード)
FAN ABN. LED: Fan Abnormal LED (ファン異常 LED)
FGB: Frame Grabber Board (画像ボード)
OPU: Operation Panel Unit (操作表示器)
PCMCIA: Personal Computer Memory Card International Association (PCMCIA)
HDD: Hard Disk Drive (ハードディスク)
MCB: Main Control Board (主制御部)
PSU: Power Supply Unit (電源部)
ARB: Audio Recording Board (音声ボード)
RMB: Remote Maintenance Board (リモートメンテナンス部)
NMEA: National Marine Electronics Association (米国海洋電子協会)
NSK: North Stabilized Kit (真方位変換部)
UPS: Uninterruptible Power Supply (無停電電源)
VESA DMTS: Video Electronics Standards Association – Discrete Monitor Timings Standard
(VESA DTRMS)
rpm: Revolution per minute (回転毎分)
BER: Bit Error Rate (ビット誤り率)
RTC: Real Time Clock (リアルタイムクロック)
MIC: Microphone Unit (マイクユニット)
DSC: Digital Signal Converter (接点信号入力器)

xi
用語

用語

A.861: IMO Performance Standard for VDR (VDR IMO 適合規格)


IEC61996: Performance Requirements for VDR (VDR IEC 機能要求)
IEC60945: General Requirements (航法・無線装置全般 IEC 機能要求)
IEC61162: Digital Interfaces Standard (デジタル通信規格)
HDT: Heading true sentence header ID of IEC61162-1 (船首方位用センテンス)
VBW: Dual ground/water speed sentence header ID of IEC61162-1 (対地/対水センテンス)
UXGA: Ultra eXtended Graphics Array (1600 x 1200: High resolution pixel)
(画像解像度:1600×1200)

xii
第1章 操作説明
1.1 装置の概要

本装置は、国際規格で要求されている船舶の運航や船体運動に関わるデータを記録し、船舶事故の
原因究明と予防を目的とします。

1.2 装置の構成

本装置の標準構成を表 1 に示します。
表 1. 標準構成表
No 機器名 型名 数量 機能概要
1 保護カプセル NDH-316A 1 ・回収用保護カプセル内の記録媒体
Protective Capsule Unit または へデータを記録します。
(PCU) NDH-316 ・水没時には、水中ビーコンが作動
し、保護カプセルの位置の捜索を
サポートします。
・NDH-316A と NDH-316 の性能は同
等であり、いずれも JCY-1800 用カ
プセルとして互換性を有していま
す。取り付け寸法も同じです。
2 防水中継箱 NQE-3163 1 ・ 保護カプセルと記録制御機間の電
Connection Box 源、LAN ケーブルを中継します。
3 記録制御機 NDV-1800 1 ・ 保護カプセルおよび CF カードに記
Recording Control Unit 録データを出力します。
(RCU) ・レーダ画像・音声データ、
IEC61162-1/-2 データを入力します。
以下収容ユニット ・システム状態を監視、制御します。
3-1 データ処理部 NDL-46 1 ・バックアップ用 CF カードを内蔵し
Data Processor Unit たメイン制御処理部
3-2 音声I/F中継部 CQD-2041 1 ・MIC、VHF からの音声信号中継用端
Audio Junction Board 子部
3-3 電源ユニット NBL-327 1 ・専用バッテリの充電制御部を内蔵し
Power Supply Unit た電源部
(PSU)
4 操作表示器 NCG-169 1 ・ VDR の動作状態を表示します。
Operation Panel Unit ・ 警報ブザー、エラーランプ、エラー
(OPU) コード LED でエラーの発生を知ら
せ、ACK スイッチによるエラー確
認操作を促します。
5 マイクユニット NVT-161 3 ・操舵室内の会話を収集し、記録制
Microphone Unit 御機へ出力します。
(MIC)

1
第1章 操作説明

No 機器名 型名 数量 機能概要
付属品
6 記録制御機用予備品 7ZXJD0080 1 ・NDV-1800 用
Spare Parts for RCU ・ファン、ヒューズ
7 カードアダプタ SLCFADU 1 ・CF カードデータ再生用
CF Card adaptor
8 LAN ケーブル KB-10T5-03LBK 1 ・3m
LAN Cable
9 再生ソフト CYC-315A 1 事故調査官用
Playback Software NDV-1800 内部に収納
10 再生ソフト/リアルタイ CYC-316A 1 ユーザ用
ムモニタ NDV-1800 内部に収納
Playback Software
/Real time monitor

本装置のオプション構成を表 2 に示します。

表 2. オプション構成表
No 機器名 型名 機能概要
1 マイクユニット NVT-161 ・ フランジを取外す事により露出形とし
Microphone Unit て設置可能
・ 標準構成を含めて最大 9 式まで増設可

2 防水マイクユニット NVT-162 ・ウィングでの会話を収集し、記録制
Waterproof Microphone Unit 御機へ出力します。
・ 標準構成及び NVT-161 を含めて最大 9
式まで増設可能
3 NSK インターフェース CHM-378 ・ 船首方位がシンクロ/ステップ信号で
NSK Interface Board 入力される場合、船速がパルス信号で
入力される場合に増設
・ NDV-1800 の内部に収納
4 接点信号入力器(64CH) NCT-72 ・ 64CH の接点信号を IEC61162-1 データ
Digital Signal Converter に変換して出力します。
(DSC) ・ CEF-60(オプション)を追加すること
により、アナログ信号の変換も可能で
す。
5 接点信号入力器(16CH) NCT-63 ・ 16CH の接点信号を IEC61162-1 データ
Digital Signal Converter に変換して出力します。
(DSC) ・ CEF-60(オプション)を追加すること
により、アナログ信号の変換も可能で

6 アナログ変換ボード CEF-60 ・ 8CH のアナログ信号を IEC61162-1 デ
Analog signal Converting ータに変換して出力します。
Board ・ NCT-72/63 の内部に収納可能
7 レーダ I/F ユニット NWP-46 ・ UXGA 画面のレーダ装置を接続する場
Radar Interface Unit 合に利用します。
付属品
8 接点信号入力器用予備品 7ZXJD0092 ・NCT-72/63 用
Spare Parts for the DSC ・ヒューズ
9 NWP-46 用予備品 7ZXJD0093 ・NWP-46 用
Spare Parts for the RIF ・ファン、ヒューズ

2
3
図 1 システム系統図
DGPS *
(Yard)
AIS *
(Yard)
Speed Log *
(Yard)
Gyro Compass *
(Yard)
Auto Pilot *
(Yard)
Rudder Angle Indicator *
(Yard)
Echo Sounder *
(Yard)
Anemometer *
(Yard)
Engin Telegraph *
(Yard)
Remote Control System *
(Yard)
Other *
(Yard)
X-Band Radar *
(JRC)
Other *
(Yard)
Other *
(Yard)
*
Dry Contact * *
(Yard)
Analog *
(Yard) * R
* G
* B
* H synch
* V synch
From AC Distributor
Dry Contact *
(Yard)
*
Mic-1 MIC1
Analog * *
(Yard) Mic-2 MIC2
*
Mic-4 MIC4
*
From AC Distributor Mic-5 MIC5
*
Mic-7 MIC7(W.P.)
*
Mic-8 MIC8(W.P.)
Gyro Compass [STEP] *
(Yard)
Gyro Compass [Synchro] *
(Yard) *
VHF Telephone No.1
*
VHF Telephone No.2
Speed Log [Pulse] *
(Yard)
*
*
AC220V 60Hz 1 phase
本装置のシステム系統図を図 1 に示します。
1.2.1 系統図
操作説明 第1章
第1章 操作説明

1.3 システムの起動・停止

1.3.1 システムの起動

ご注意 記録制御機は鍵により前面扉を開けないと操作できません。

■ 本装置は、全装置の接続終了後、下記手順に従ってシステムを起動してください。

1. 記録制御機(Recording Control Unit)を起動します。

1) 鍵により前面扉を開けます。
2) 電源ユニット(PSU)の電源スイッチを ON します。
3) 電源ユニット(PSU)の POWER LED が点灯します。
4) 主制御部(MCB)の CARD LED が点灯します。
5) 主制御部(MCB)の REC LED が点灯します。

2. 操作表示器(Operation Panel Unit)を起動します。

操作表示器(OPU)用の DC 電源は、記録制御機(RCU)内の電源ユニット(PSU)よ
り供給されます。
1) 記録制御機(RCU)内の電源ユニット(PSU)の電源スイッチが ON されると同時に
操作表示器の POWER LED が点灯します。
2) 数秒後に VDR の記録状態を示す Recording LED が点灯します。

3. 保護カプセル(Protective Capsule Unit)を起動します。

保護カプセル(PCU)用の DC 電源は、記録制御機(RCU)内の電源ユニット(PSU)から供
給されます。
記録制御機(RCU)内の電源ユニット(PSU)の電源が ON されると同時に保護カプセル
(PCU)も自動的に起動されます。

4. マイクユニット(Microphone Unit)を起動します。

マイクユニット(MIC)は、記録制御機(RCU)内の音声記録部(ARB)から電力を供給され
ます。記録制御機(RCU)内の電源ユニット(PSU)の電源が ON されると同時にマイクユ
ニット(MIC)も自動的に起動されます。

4
第1章 操作説明

5. オプションユニット(Option Unit)を起動します。

対象となるオプションユニットは接点信号入力器(DSC)、レーダ I/F ユニット(Radar


Interfcae Unit)です。
このオプションユニット用の AC 電源は記録制御機(RCU)より供給されます。また、
AC 電源の供給は記録制御機内の電源ユニット(PSU)の電源スイッチに連動していま
す。
記録制御機(RCU)内の電源ユニット(PSU)の電源が ON されると同時にオプションユ
ニットも自動的に起動されます。オプションユニットの電源スイッチは常時 ON 状態
としてください。

5.1 接点信号入力器
電源スイッチを ON にします。
1) 正面カバーを固定している 4 本のビスを外します。
2) 筐体内部の電源スイッチを ON にします。

5.2 レーダ I/F ユニット


電源スイッチを ON にします。
1) 正面パネルの電源スイッチを ON にします。

6. システム正常動作確認

記録制御機(RCU)、操作表示器(OPU)、保護カプセル(PCU)、マイクユニット(MIC)
の電源が ON になり、正常に動作している場合、下記の表示になりますので確認して
ください。

・記録制御機の主制御部(MCB)の表示
1) REC LED 点灯
2) CARD LED 点灯
3) MEDIA LED 消灯
・記録制御機の電源ユニット(PSU)の表示
1) POWER LED 点灯
2) BATT. ABN. LED 消灯
3) BATT. OP. LED 消灯
4) FAN ABN.LED 消灯
・操作表示器(OPU)の表示
1) POWER LED 点灯
2) RECORDING LED 点灯
3) ALARM LED 消灯
4) ERROR コード表示 LED 消灯
*エラー発生時にエラー要因を示す 2 桁又は 4 桁のコードが表示されます。

5
第1章 操作説明

1.3.2 システムの停止

■ 本装置は、下記手順に従ってシステムを停止してください。

ご注意 記録制御機は鍵により前面扉及び上ブタを開けないと操作できません。

ご注意 起動状態で配電盤のブレーカを落とさないでください。電源ユニット
(PSU)によるバッテリ運転になります。

ご注意 記録制御機(RCU)の電源を OFF する前に主制御部(MCB)の


CARD STOP スイッチにより CF カードへの記録を必ず停止してください。
CF カードへの記録が出来なくなることがあります。

1. 記録制御機(Recording Control Unit)を停止します。

1) 鍵により前面扉を開けます。
2) 主制御部(MCB)の CARD STOP スイッチを押して CF カードへのデータの記録を必ず停
止してください。
・主制御部(MCB)の CARD LED が消灯していることを確認してください。
・CARD LED が点灯した状態で電源を OFF すると CF カードへの記録が出来なくな
ることがあります。
3) 電源ユニット(PSU)の POWER スイッチを OFF してください。
4) 全ての LED が消灯します。

2. 操作表示器(Operation Panel Unit)を停止します。

記録制御機(RCU)内の電源ユニット(PSU)の電源が OFF されると同時に操作表示器


(OPU)も停止します。

3. 保護カプセル(Protective Capsule Unit)を停止します。

記録制御機(RCU)内の電源ユニット(PSU)の電源が OFF されると同時に保護カプセル


(PCU)も停止します。

4. マイクユニット(Microphone Unit)を停止します。

記録制御機(RCU)内の電源ユニット(PSU)の電源が OFF されると同時にマイクユニッ


ト(MIC)も停止します。

5. オプションユニット(Option Unit)を停止します。

記録制御機(RCU)内の電源ユニット(PSU)の電源が OFF されると同時にオプションユ


ニット(Option Unit)も停止します。

6
第1章 操作説明

1.4 操作説明
・ここでは基本的な操作方法を説明します。

・基本的な操作は、記録制御機(RCU)の主制御部(MCB)にて行います。
(記録制御機(RCU)は、鍵により前面扉を開けることにより操作可能になります。

1.4.1 保護カプセルへの記録を停止する場合

下記の状況以外では保護カプセル(PCU)への記録を停止
ご注意 しないでください。
・ メンテナンスで港に停泊中の場合
・ ドックインした場合
・ 海難事故発生などで、関係官庁より記録停止の指示を受けた場合

1) 主制御部(MCB)の REC STOP スイッチを押します。


2) 主制御部(MCB)の REC LED が点滅します。
3) 約1分後、主制御部(MCB)で点滅中の REC LED が消灯し、保護カプセルへの記録を
停止します。
* 操作表示器(OPU)の RECORDING LED も同様に消灯します。
4) 記録が停止すると、操作表示器(OPU)で記録が停止されたことを示すアラームを出
力します。(エラーコード:22__)
記録を再開すると、このエラーは解除されます。

1.4.2 保護カプセルへの記録を再開する場合

ご注意 入港及びドックイン時に記録を停止した場合は、出港時に必ず記録を再開して
ください。万が一の事故発生時にデータを記録できません。

1) 主制御部(MCB)の REC START スイッチを押します。


2) 主制御部(MCB)の REC LED が点灯します。
3) 保護カプセルへの記録を再開します。
* 操作表示器(OPU)の RECORDING LED も同様に点灯します。
4) 記録が停止された事を示すアラーム(エラーコード:22__)が解除されます。

1.4.3 CF カード内のデータをバックアップする場合

1) 主制御部(MCB)の CARD LED が点灯していることを確認してください。


2) 主制御部(MCB)の CARD STOP スイッチを押します。
3) 主制御部(MCB)の CARD LED が約 5 秒間、点滅します。
4) 主制御部(MCB)の CARD LED が消灯する事を確認し、CARD EJECT ボタンを押しま
す。

7
第1章 操作説明

5) CF カードを抜き取り、カードアダプタを取付けて PCMCIA スロットの実装されてい


る PC に挿入し、コピーします。
6) コピーが完了したら CF カードを主制御部(MCB)のカードスロットに差し込みます。
(CF カードを差し込む時の向きは、CF カードの JRC ラベルの貼ってある面が右側です。)
7) 主制御部(MCB)の CARD LED が点灯することを確認してください。

ご注意 CF CARD LED が消灯した状態が 10 分以上継続すると主制御部(MCB)の


MEDIA LED が点灯します。また、操作表示器(OPU)の警報ブザーが作動し、
ALARM ランプとエラーコード LED が点滅します。
ます。(エラーコード:31__)
CF カードを主制御部(MCB)のカードスロットに差し込むと警報は、解除され
ます。

ご注意 CF カード バックアップを頻繁に行う場合は、もう1枚 CF カードをお買い求


めになることをお薦めします。(CF カードコード:7HRJD0002)

1.4.4 CF カードの記録データを保全する場合

海難事故発生時に、CF カードへの上書き記録を禁止して、CF カードに記録されたデータを保


全することができます。保全すると、VDR を再起動したり、CF カードを抜き差ししたりして
も、その CF カードへの記録は開始されません。

ご注意 カプセルへの記録は停止しません。事故発生時の対応は、
1.4.5 項「事故発生時の対応(ガイドライン)」を参照してください。

1. CF カード記録データを保全する
1) 主制御部(MCB)の CARD STOP スイッチを CARD LED と MEDIA LED が点滅するまで
(約 10 秒間)押します。
2) CF カードへのデータの上書きは禁止されます。
CARD LED と MEDIA LED の点滅は、CF カードへの上書きが禁止され、保全さ
れていることを示しています。また、操作表示器(OPU)に CF カードへの上書き
禁止を示すエラー(エラーコード: 03__ )が発生しますので、ACK キーを押下し
ALARM ブザーを停止してください。

2. CF カード記録データの保全を解除する
以下の場合には、CF カードの保全状態を解除することで、CF カードへの記録を再開す
ることができます。
・事故時の記録データを関係官庁に引き渡し、記録データを保全する必要がなくなっ
た場合
・間違って、CF カードの記録データを保全した場合

8
第1章 操作説明

1) 上書き禁止された CF カードを主制御部(MCB)のカードスロットに差し込みます。
2) 主制御部(MCB)の CARD LED と MEDIA LED が点滅します。
3) 主制御部(MCB)の REC START スイッチを CARD LED が点灯するまで(約 10 秒間)
押します。
4) CF カードへの上書き禁止が解除され、記録を再開します。また、操作表示器(OPU)
のエラー表示(エラーコード: 03__ )が解除されます。

1.4.5 事故発生時の対応(ガイドライン)

海難事故発生時には、事故発生までの船体情報、操船情報を記録したデータを保全する必要が
あります。本章では、データ保全についてのガイドラインを示します。
事故状況を見極めて、記録データの保全に努めてください。保全した記録データは関係官庁か
ら提出を要求されますので、データの移管方法については当社担当営業までご相談ください。

1. CF カード記録データの保全
手順 対処内容 記録制御機での操作
1 海難事故発生時には、CF カードへの上書き CARD STOP スイッチを CARD LED と
を禁止して、記録データを保全します。 MEDIA LED が点滅するまで(約 10 秒間)
押します。
(1.4.4 項を参照)
2 CF カードを記録制御機(RCU)より取り外 CF カード EJECT ボタンを押します。
します。

3 CF カードに記録されているデータをパソ
コンの HDD へコピーします。*1
コピーしたデータの内容(Log/Audio/
Visual 各フォルダの下位フォルダの名前が
データ記録日時を示します)を確認します。
4 コピー終了後、CF カードを記録制御機 CARD LED と MEDIA LED が点滅すること
(RCU)に戻します。 を確認してください。

*1 CF カード内にある全てのフォルダ、ファイルをパソコンにコピーしてください。
記録データは PC に“コピー”し、“移動”しないでください。
CF カードの記録データは、関係官庁へ記録データが引き渡されるまで絶対に削除しない
でください。

関係官庁より記録データの要求があった場合には、パソコンにコピーしたデータを DVD にコ
ピーして提出してください。
CF カードを提出する場合には、代替カードが必要となりますので、当社担当営業までご相談
ください。
関係官庁の事故調査官が乗船する場合には、調査官が VDR の CF カードより記録データをダウ
ンロードします。上書き禁止状態にした CF カードを必ず記録制御機(RCU)に戻しておいてく
ださい。

9
第1章 操作説明

2. カプセル記録データの保全
カプセルへの記録停止は関係官庁の指示に従ってください。
手順 対処内容 記録制御機での操作
1 VDR を停止します。 POWER スイッチを OFF します。
(1.5.2 項を参照)

記録制御機(RCU)用のカギが見つからず、扉を開けることができない場合にはブレーカを落と
してください。ブレーカを落としてから 2 時間で自動的に記録を停止し、
電源 OFF になります。

ご注意 VDR は主電源が停電してから、2 時間で自動的に記録を停止します。事故に


より避難が必要な場合は、保全操作の必要はありません。記録データは、カプ
セルを回収することにより取得されます。

ご注意 CF カードよりデータをコピーするためには、PCMCIA カードスロットを有す


るパソコンと約 2GB の HDD が必要になります。 船内に該当するパソコン
がない場合には当社営業までご相談ください。
通常のノートパソコンは PCMCIA カードスロットを有しています。

1.4.6 操作表示器(Operation Panel Unit)のブザーを停止する場合

・操作表示器(OPU)の ALARM ブザーが作動した場合。


1) 操作表示器(OPU)の ACK スイッチを押します。
2) 操作表示器(OPU)の ALARM ブザーは停止します。
3) 複数の警報が検出された場合は、警報の数だけ ACK スイッチを押してください。

10
第1章 操作説明

1.5 記録制御機 Recording Control Unit (NDV-1800)

1.5.1 記録制御機 Recording Control Unit (NDV-1800)の各部の名称

1) 鍵
(Key hole)

図 2 記録制御機の各部の名称
(前面扉を閉めた状態)

2) 電源ユニット
(Power Supply Unit:PSU)

3) データ処理部
(Data Processor Unit)

4) 外部信号接続 I/F 部
(I/F for connecting external signals)

5) バッテリ
(Battery)

図 3 記録制御機の各部の名称
(前面扉を開けた状態)

11
第1章 操作説明

表 3. 記録制御機の各部の名称とはたらき
番号 名称とはたらき
1) 鍵
前面扉の開閉時に使用します。
2) 電源ユニット(Power Supply Unit:PSU)
記録制御機(RCU)の電源ユニット。専用バッテリを接続し、停電時にも保護カプ
セル(PCU)、操作表示器(OPU)及びマイクユニット(MIC)に電源を供給します。
3) データ処理部(Data Processor Unit)
記録制御機(RCU)のメイン処理ユニット。バックアップ用 CF カードを内蔵。
4) 外部信号接続 I/F 部(I/F for connecting external signals)
・RGB コネクタパネル
レーダとの接続用 RGB コネクタ中継パネル。(BNC コネクタ)
・音声 I/F 部
マイク、VHF 信号を接続する端子台。
・外部信号 I/F 部
シリアルデータ(IEC61162-1/2)接続用端子台
保護カプセル接続用端子台
操作表示器接続用端子台
・サービスコンセント
メンテナンス PC 用 AC 電源アウトレット(AC100~AC240V)
5) バッテリ
バッテリが電源ユニットに接続されています。
停電時の船橋内会話を 2 時間記録するために、記録制御機、保護カプセル、操作
表示器、マイクの電源として利用されます。

注 意
記録制御機のサービスコンセントの形状は、AC100V 用ですが記録制御機の入力
電圧がそのまま出力されています。AC220V が出力されている時に AC100V の機
器を接続しないでください。誤って接続すると故障の原因となることがありま
す。

12
第1章 操作説明

1.5.2 電源ユニット (Power Supply Unit:PSU)

1.5.2.1 電源ユニットの各部の名称

1) POWER スイッチ 3) POWER LED 8) バッテリ電圧テスト端子

7) 停電テストスイッチ 9) ファン

2)ヒューズ 4) BATTERY ABN. LED 5) BATTERY OP. LED 6) FAN ABN. LED

図 4 電源ユニットの各部の名称

表 4. 電源ユニットの各部の名称とはたらき
番号 名称とはたらき
1) POWER スイッチ
記録制御機(RCU)のメイン電源スイッチ。
2) ヒューズ
AC 入力電源ライン保護用ガラス管ヒューズ(5A)。
3) POWER LED
外部からの AC 電源による動作中に点灯します。停電時のバッテリ動作中は、消
灯します。
4) BATTERY ABN. LED
バッテリからのバックアップ動作が不可能な時に点灯します。
5) BATTERY OP. LED
停電時のバッテリによるバックアップ動作中に点灯します。
6) FAN ABN. LED
2 式のファンのうちどちらか一方のファンの回転が停止した場合に点灯します。
7) 停電テストスイッチ
停電機能をテストする為のスイッチです。押している間、外部からの AC 電源を
遮断します。手を離すと復旧します。
8) バッテリ電圧テスト端子
バッテリの電圧をテスタで測定するための端子です。外部からの AC 電源による
動作中は、充電電圧がモニタ出来ます。バッテリ電圧をモニタする場合は、
POWER スイッチを OFF して測定してください。
9) ファン(電源ユニットの右側面:2 式)
AC/DC 電源部空冷用ファン。(回転検出機能付)

13
第1章 操作説明

1.5.2.2 電源ユニットの操作方法

1. 電源を起動する場合
1) POWER スイッチを ON します。
2) POWER LED が点灯します。

2. 電源を停止する場合
1) 電源を停止する前に主制御部(MCB)の CARD STOP スイッチを ON し、CF
カードへのバックアップを停止してください。

電源を停止する場合、主制御部(MCB)の CARD LED が消灯していることを


ご注意 確認してください。
CARD LED が点灯している状態で POWER スイッチを OFF すると CF カード
に記録出来なくなることがあります。必ず、CARD STOP スイッチにより CF
カードへの記録を停止してください。

2) 主制御部(MCB)の CARD STOP スイッチを押します。


3) 主制御部(MCB)の CARD LED が消灯する事を確認します。
4) POWER スイッチを OFF します。
5) 全ての LED が消灯します。

3. 停電試験を行う場合
1) 停電テストスイッチを押し続けます。(押している間、AC 入力を遮断します)

2) 停電テストスイッチを押している間、以下の様に動作すれば停電機能及びバ
ッテリは正常に機能しています。
・ 電源ユニットの POWER LED が消灯します。
・ 電源ユニットの BATTERY OP. LED が点灯します。
・ 操作表示器(OPU)の ALARM ブザーが作動します。
・ 操作表示器(OPU)の ALARM ランプとエラーコード LED が点滅
します。(エラーコード: 10__ )
・ 操作表示器(OPU)の POWER LED が点滅します。

3) 停電テストスイッチを戻すと以下の様に動作します。
・ 電源ユニットの POWER LED が点灯します。
・ 電源ユニットの BATTERY OP. LED が消灯します。
・ 操作表示器(OPU)の ALARM ブザーが停止します。
・ 操作表示器(OPU)の ALARM ランプとエラーコード LED が消灯
します。
・ 操作表示器(OPU)の POWER LED が点灯します。

14
第1章 操作説明

4. FAN ABN. LED が点灯した場合


3.3 項のトラブル・シューティングにより対応する処置を行います。

注 意
FAN ABN. LED が点灯した場合、電源ユニット用空冷ファンが停止していますので
空冷ファンを交換する必要があります。そのまま継続して使用しますと故障の
原因となることがあります。当社の営業部又はお近くの支社・支店・営業所また
は当社代理店に交換をご依頼ください。

15
第1章 操作説明

1.5.3 データ処理部 (Data Processor Unit)

1.5.3.1 データ処理部の各部の名称

9) AUDIO IN コネクタ
17) RGB1 IN コネクタ
7) CF カード
18) RGB2 IN コネクタ
2) REC START スイッチ

8) CF カード EJECT ボタン


12) RMS OP. LED
1) REC LED
13) RMS SYS. LED
4) CARD LED
14) DATA LED
5) MEDIA LED

15) HUB (JRC-LAN)

3) REC STOP スイッチ


6) CARD STOP スイッチ 16) LAN コネクタ (EXT-LAN)

10) HUB (VDR-LAN)


19) LAN コネクタ(VDR-LAN)

11) LAN コネクタ (JRC-LAN)

MAIN CONTROL BOARD REMOTE MAINTENANCE BOARD FRAME GRABBER BOARD


主制御部(MCB) リモートメンテナンス部 画像記録部
MCB 上段に音声記録部(ARB 実装)

図 5 データ処理部の各部の名称

表 5. データ処理部の各回路名称と機能
回路名称 機能
MAIN CONTROL BOARD 記録制御機のメイン処理部です。
(MCB) 収集したデータを保護カプセルと CF カードに記録しています。
主制御部 CH01~CH16 のシリアルデータ(IEC61162-1/2)と音声信号を収
集しています。
(音声信号は MCB 上にマウントされた音声記録部(ARB)で収
集し、圧縮処理し、MCB へ出力されます。)

REMOTE MAINTENANCE BOARD CH17~CH32 のシリアルデータ(IEC61162-1/2)を収集し、主制


(RMB) 御部(MCB)に出力します。
リモートメンテナンス部
FRAME GRABBER BOARD RADAR からの画像信号をキャプチャし、圧縮後、主制御部(MCB)
(FGB) に出力します。
画像記録部 オプション

16
第1章 操作説明

表 6. データ処理部の各部の名称とはたらき
番号 名称とはたらき
1) REC LED (MCB)
保護カプセル(PCU)に正常に記録出来ている時に点灯します。
2) REC START スイッチ (MCB)
保護カプセル(PCU)への記録を再開する時に押します。
CF カード記録データの保全を解除する場合には、CARD LED が点灯するまで(約 10 秒間)
押します。
3) REC STOP スイッチ (MCB)
保護カプセル(PCU)への記録を停止する時に押します。
4) CARD LED (MCB)
CF カードに正常に記録出来ている時に点灯します。
CF カードが着脱可能な時に消灯します。
CF カード記録データが保全されている時に MEDIA LED と共に点滅します。
5) MEDIA LED (MCB)
CF カードが実装されていないか CF カードに正常に記録出来ない時に点滅します。
CF カード記録データが保全されている時に CARD LED と共に点滅します。
6) CARD STOP スイッチ (MCB)
CF カードへの記録を停止する時に押します。
CF カード記録データの保全する場合には、CARD LED と MEDIA LED が点滅するまで(約
10 秒間)押します。
7) CF カード (MCB)
保護カプセル(PCU)に記録しているデータと同じデータを記録します。容量は、2GB です。
8) CF カード イジェクトボタン (MCB)
CF カードを引き抜く時に押します。
CARD STOP スイッチにより CARD LED が消灯していることを確認してから引き抜きま
す。
9) AUDIO IN コネクタ (MCB)
マイクユニット(MIC)及び VHF 通信装置からの音声信号を入力するコネクタです。音声 I/F
中継部(Audio Junction Board)に接続します。
10) HUB (MCB)
4 ポートのスイッチング HUB 機能を MCB に内蔵しています。
VDR-LAN を構成します。
11) LAN コネクタ (MCB)
MCB の HUB(VDR-LAN)と外部 LAN を接続(ルーティング)するためのポートです。
12) RMS OP. LED (RMB)
リモートメンテナンスボードの動作中に点灯します。
13) RMS SYS. LED (RMB)
リモートメンテナンスボードにてエラーが発生した場合に点灯します。
14) DATA LED (RMB)
メンテナンスデータの受信エラー時に点灯します。
15) HUB (RMB)
4 ポートのスイッチング HUB 機能を RMB に内蔵しています。
JRC-LAN を構成します。
16) LAN コネクタ (RMB)
RMB の HUB(JRC-LAN)と外部 LAN を接続(ルティング)するためのポートです。
17) RGB1 IN コネクタ (FGB)
メイン RADAR からの映像信号を入力するコネクタです。RGB コネクタパネルに接続しま
す。
18) RGB2 IN コネクタ (FGB)
サブ RADAR からの映像信号を入力するコネクタです。RGB コネクタパネルに接続します。
19) LAN コネクタ (FGB)
MCB の HUB(VDR-LAN)と接続するための LAN ポートです。

17
第1章 操作説明

1.5.3.2 データ処理部の操作方法

1. 保護カプセル (Protective Capsule Unit) への記録を停止させるには

ご注意 運航中に保護カプセル(PCU)への記録を停止しないで
ください。万が一の事故時のデータを記録できなくなります。

1) 主制御部(MCB)の REC STOP スイッチを押します。


2) 主制御部(MCB)の REC LED が点滅します。
3) 約1分後、主制御部(MCB)で点滅中の REC LED が消灯し、保護カプセルへの記録を
停止します。
* 操作表示器(OPU)の RECORDING LED も同様に消灯します。
4) 記録が停止すると、操作表示器(OPU)に記録が停止されたことを示すアラームを出
力します。(エラーコード:22__)
記録を再開すると、このエラーは解除されます。

2. 保護カプセル (Protective Capsule Unit) への記録を再開させるには

1) 主制御部(MCB)の REC START スイッチを押します。


2) 主制御部(MCB)の REC LED が点灯します。
3) 保護カプセルへの記録を再開します。
* 操作表示器(OPU)の RECORDING LED も同様に点灯します。
4) 記録が停止された事を示すアラーム(エラーコード:22__)が解除されます。

3. CF カード内のデータをバックアップするには

ご注意 内部操作表示部の CARD LED が点灯している時に CF カードを取り出さな


いでください。CF カードがこわれる事があります。
必ず、CARD LED が消灯している事を確認してください。

1) 主制御部(MCB)の CARD LED が点灯していることを確認してください。


2) 主制御部(MCB)の CARD STOP スイッチを押します。
3) 主制御部(MCB)の CARD LED が約 5 秒間、点滅します。
4) 主制御部(MCB)の CARD LED が消灯する事を確認し、CARD EJECT ボタンを押しま
す。
5) CF カードを抜き取り、カードアダプタを取付けて PCMCIA スロットの実装されてい
る PC に挿入し、コピーします。
6) コピーが完了したら CF カードを主制御部(MCB)のカードスロットに差し込みます。
CF カードの JRC ラベルの貼ってある面が右側です。)
(CF カードを差し込む時の向きは、
7) 主制御部(MCB)の CARD LED が点灯することを確認してください。
8) CARD LED が点灯すると CF カードに記録データを自動的に書き込み始めます。
9) CF カードに記録されていた古いデータは、13.5 時間以上前のデータから消去されま
す。

18
第1章 操作説明

ご注意 CARD LED が消灯した状態が 10 分以上継続すると主制御部(MCB)の MEDIA


LED が点灯します。また、操作表示器(OPU)の警報ブザーが作動し、ALARM
ランプとエラーコード LED が点滅します。(エラーコード:31__)
CF カードを主制御部(MCB)のカードスロットに差し込むと警報は、解除され
ます。

4. CF カード記録データを保全するには
1) 主制御部(MCB)の CARD STOP スイッチを CARD LED と MEDIA LED が点滅するまで
(約 10 秒間)押します。
2) CF カードへのデータの上書きは禁止されます。
CARD LED と MEDIA LED の点滅は、CF カードへの上書きが禁止され、保全さ
れていることを示しています。また、操作表示器(OPU)に CF カードへの上書き
禁止を示すエラー(エラーコード: 03__ )が発生しますので、ACK キーを押下し
ALARM ブザーを停止してください。

5. CF カード記録データの保全を解除するには
以下の場合には、CF カードの保全状態を解除することで、CF カードへの記録を再開す
ることができます。
・事故時の記録データを関係官庁に引き渡し、記録データを保全する必要がなくなっ
た場合
・間違って、CF カードの記録データを保全した場合

1) 上書き禁止された CF カードを主制御部(MCB)のカードスロットに差し込みます。
2) 主制御部(MCB)の CARD LED と MEDIA LED が点滅します。
3) 主制御部(MCB)の REC START スイッチを CARD LED が点灯するまで(約 10 秒間)
押します。
4) CF カードへの上書き禁止が解除され、記録を再開します。また、操作表示器(OPU)の
エラー表示(エラーコード: 03__ )が解除されます。

19
第1章 操作説明

1.6 操作表示器 Operation Panel Unit (NCG-169)

1.6.1 操作表示器 (NCG-169)の各部の名称

7) HEADING LED
HEADING 8) 詳細 ALARMLED
ALARM DETAIL
1) POWER LED POWER 9) MODE スイッチ
MODE
2) RECORDING LED RECORDING 10) ERROR コード LED
SYSTEM CODE
3) ALARM LED ALARM

11) カーソルスイッチ
5) ALARM ACK スイッチ ACK DIM

ENT 12) ENTER スイッチ


4) DIMMER スイッチ
6) ALARM ブザー
NCG-169 VDR OPERATION PANEL

図 6 操作表示器の各部の名称

表 7. 操作表示器の各部の名称とはたらき(1/2)

番号 名称とはたらき
1) POWER LED
記録制御機(RCU)を電源 ON した時に点灯します。
停電時には点滅表示に変わります。停電が 2 時間継続した場合には、記録制御機が自
動で電源 OFF しますので消灯します。
2) RECORDING LED
記録制御機(RCU)が保護カプセルにデータを記録している時に点灯します。
3) ALARM LED
VDR システムがエラーを検出すると点滅します。
ALARM ACK スイッチを押すと点灯に変わります。
エラーが解除され正常稼働に戻れば消灯します。
4) DIMMER スイッチ
LED の輝度を調整します。
スイッチを押すと段階的に輝度が変化します。
5) ALARM ACK スイッチ
エラー発生時にエラー内容を確認してから押してください。
警報ブザーが停止し、ALARM LED が点滅から点灯に変化します。
複数のエラーが発生した場合には、発生したエラー数と同じ回数だけ押す必要があり
ます。
6) ALARM ブザー
VDR システムがエラーを検出すると鳴動します。
ALARM ACK スイッチを押すと止まります。

20
第1章 操作説明

表 7. 操作表示器の各部の名称とはたらき(2/2)

番号 名称とはたらき
7) HEADING LED
操作表示器が NSK モードで動作している時に点灯します。
船首方位(Heading)の初期値が未入力時の場合は点滅します。
NSK モードは記録制御機(RCU)に NSK-I/F ボード(オプション)を増設し、シン
クロ信号またはステップ信号で船首方位データを入力している場合に使用する動
作モードです。船首方位データをシリアルデータ(IEC-61162)で入力している場
合には、NSK モードが動作することはありませんので、本 LED は点灯しません。
8) 詳細 ALARM LED
操作表示器が通常モード(NSK モードでない)で動作している時に点灯します。通
常は常時点灯となります。
ソフトウェアバージョン表示時には点滅します。
9) MODE スイッチ
操作表示器の動作モードを変更する時に押します。
スイッチを押すことで、通常モードと NSK モードが順番に切り替わります。
NSK モードは記録制御機(RCU)に内蔵されている NSK-I/F ボード(オプション)
を増設し、シンクロ信号またはステップ信号で船首方位データを入力している場合
に使用する動作モードです。船首方位データをシリアルデータ(IEC-61162)で入
力している場合には、NSK モードが必要ありませんので、本スイッチを押してもモ
ードは切り替わりません。
10) ERROR コード LED
4桁の数値でエラーコード、または船首方位値を表示します。
・通常モード
エラー発生時にエラー要因を示す 4 桁又は 2 桁のコードが表示されます。
・NSK モード
船首方位値を表示します。
11) カーソルスイッチ
複数のエラー発生時に手動で表示するエラーコードを切り替える場合や、船首方位
の初期値を入力する時に使用します。
・通常モード
上下もしくは左右のキーを押すと、表示するエラーコードが切り替わります。
・NSK モード
左右キーで入力対象桁が移動します。入力対象桁の数値が点滅表示されます。
数値を入力したい桁の数字が点滅するよう左右キーで移動してください。
上下キーで入力値を指定します。
入力値になるよう上下キーで値を変更してください。
12) ENTER スイッチ
ソフトウェアバージョンを表示する場合や、船首方位の入力初期値を登録する時に
使用します。
・通常モード
4 桁数値 LED で表示している内容をソフトウェアバージョン表示に切り替えま
す。ソフトウェアバージョンの表示中に ENTER スイッチを押すと、通常のエラ
ーコード表示に戻ります。
ソフトウェアバージョン表示は 5 分経過後に自動で通常モードに戻りエラーコー
ド表示に切り替わります。
4 桁数値がソフトウェアバージョンを表示している時には、“詳細 ALARM LED”
が点滅します。
・NSK モード
4 桁数値 LED に表示している値を船首方位の初期値として登録します。
登録後、自動で通常モードに戻ります。
* NSK モードの詳細は 1.6.3 項を参照してください。

21
第1章 操作説明

1.6.2 操作表示器の操作方法(通常モード)

1. エラーが発生した場合
1) VDR にエラーが発生するとブザーが鳴動します。
2) ALARM LED が点滅します。
3) ERROR コード(4 桁数値又は 2 桁数値)LED が点滅します。
4) ALARM ACK スイッチを押してください。ブザーの鳴動が止まります。
5) 表 8 のエラーコード表を参照して、エラー要因を確認してください。
6) 3.3 項のトラブルシューティングより対応する処置を行います。

2. 複数のエラーが発生した場合
1) 最新のエラーの発生に伴いブザーが鳴動します。
2) ALARM LED が点滅します。
3) 最新のエラーを示すエラーコードが ERROR コード(4 桁数値又は 2 桁数値)LED に表
示され点滅します。
4) ALARM ACK スイッチを押してください。ブザーの鳴動が止まります。
5) 複数のエラーが同時に発生した場合には、発生したエラー数と同じ回数だけ ALARM
ACK スイッチ押すことでブザーの鳴動が停止します。
6) 表 8 のエラーコード表を参照して、エラー要因を確認してください。
・自動スクロール
複数のエラーが発生している場合には、3 秒周期で表示するエラーコードが自動で
切り替わります。
・ 手動スクロール
カーソルスイッチ(上下、左右キー)を押すと表示するエラーコードが切り替わ
ります。
7) 3.3 項のトラブルシューティングより対応する処置を行います。

3. 停電した場合
1) 停電になるとブザーが鳴動します。
2) POWER LED と ALARM LED が点滅します。
3) ERROR コード LED はエラーコード:“10__”を表示して点滅します。
4) ALARM ACK スイッチを押してください。ブザーの鳴動が止まります。
停電の場合には、ALARM ACK スイッチを押さなくても 2 分経過後に自動でブザーの鳴
動が停止されます。
5) 停電時には、マイクからの音声のみ記録されます。他データは記録されません。
6) 停電が 2 時間継続すると、記録制御機は自動で電源 OFF になります。
7) もし、停電が誤検出されるような場合は、3.3 項のトラブルシューティングより対応する
処置を行います。
8) 停電が 2 時間以内に復旧した場合は、自動的に通常の記録モードに戻ります。

22
第1章 操作説明

4. LED の輝度を調整する場合
1) DIMMER スイッチを押して操作表示器の LED 輝度を調整します。
2) DIMMER スイッチを押すたびに LED 輝度が変化します。
3) 最低輝度に調整しても LED は消灯しません。

5. ソフトウェアバージョンを表示させる場合
1) ENTER スイッチを押します。
2) 操作表示器がソフトウェアバージョンの表示モードになります。
3) ERROR コード LED にソフトウェアバージョンが表示されます。
4) ソフトウェアバージョン表示中は、ALARM DETAIL LED が点滅になります。
5) 更に ENTER スイッチを押すと、操作表示器が通常モードに戻ります。
6) ソフトウェアバージョン表示は、ENTER スイッチを押さなくても 5 分後に自動で終了し、
通常モードに戻ります。

23
第1章 操作説明

表 8. 操作表示器のエラーコード表 (1/3)
エラーコード
対象 内容
SYSTEMCODE
0 0 システム イニシャルエラー
保護カプセル(PCU)と記録制御機(RCU)の構成情報が不一致
0 1
船首方位初期値アラーム(NSK I/F からの入力時のみ)
船首方位(HEADING)の初期値が未入力(入力要求)
0 3
CF カード保全
CF カードの記録データを保全している。
1 0 電源 停電アラーム
停電によりバッテリバックアップ電源で動作
1 1
電源ファンアラーム
2 式の内蔵ファンのうち、どちらか一方のファンの回転が停止
1 2
電源接続アラーム
電源ユニット(PSU)を制御するためのケーブルが外れている。
2 0 カプセル カプセル制御エラー
保護カプセル(PCU)がエラー応答を出力しているため、保護カプセ
ルにデータを記録することができない。
2 1
BER エラー
保護カプセル(PCU)にて記録データの書き込み後の読み出しチ
ェックにより、BER 値が 10-8以上
P P

2 2
記録停止アラーム
記録制御機(RCU)の REC STOP スイッチにより記録を停止して
いる。
2 3
カプセル LAN エラー
保護カプセル(PCU)と記録制御機(RCU)が通信できないため、保護
カプセルにデータを記録することができない。

24
第1章 操作説明

表 8. 操作表示器のエラーコード表 (2/3)
エラーコード
対象 内容
CODE
SYSYTEM
3 0 主制御 初期化処理エラー
主制部(MCB)が正常起動していない。
3 1
CF カードアラーム
CF カードが取り出されてから 10 分以上経過している。
3 2
CF カードのメディアエラー
CF カードへのデータ記録に失敗している。
3 3
時刻校正エラー
GPS データによる VDR 内部時計の自動時刻校正に失敗
3 4
RTC エラー
時計 IC をバックアップしているバッテリの電圧低下(寿命)
3 5
EEPROM チェックサムエラー
主制御部(MCB)の EEPROM(メインメディア)に登録され
ているセットアップデータの異常を検出
3 6
EEPROM アクセスエラー
主制御部(MCB)のセットアップデータを登録している
EEPROM へのアクセスに失敗
3 7
Flash ROM チェックサムエラー
主制御部(MCB)の Flash ROM(バックアップメディア)に登
録されているセットアップデータの異常を検出
3 8
MCB セットアップデータエラー
主制御部(MCB)の EEPROM(メインメディア)に登録され
ているセットアップデータの設定値が異常
4 0 音声記録 ARB 初期化処理エラー
音声記録部(ARB)が正常起動していない。
4 1
ARB 制御エラー
主制御部(MCB)が音声記録部(ARB)からの音声データ取
得に失敗
4 2
ARB エラー
音声記録部(ARB)が音声信号のデジタル変換・圧縮処理に失

5 1 マイク マイクテストエラー
:
9 起動時及び 12 時間毎に実行するマイクテストにより、異常を
判定
2 桁目の数字(1~9)は、異常判定したマイクユニット番号を示し
ています。

25
第1章 操作説明

表 8. 操作表示器のエラーコード表 (3/3)
エラーコード
対象 内容
SYSYTEM CODE
シリアル シリアルデータ(IEC61162-1/2)受信エラー
データ記録
各センサ装置より入力しているシリアルデータが正常に受信さ
6 0 * *
れていません。
下二桁の“**”コードは、エラー判定した対象の装置を示しま
す。表 9 のコード・装置変換表を参照してください。
シリアルデータ(IEC61162-1/2)受信設定エラー
各センサ装置に対する受信条件の設定異常
6 1 * * 受信条件が誤っているため、シリアルデータを受信・記録する
ことができません。
下二桁の“**”コードは、エラー判定した対象の装置を示しま
す。表 9 のコード・装置変換表を参照してください。
7 0 画像記録 CH1 メインレーダ画像取得エラー
CH1 に接続されているメインレーダの画像信号が検出されな
い。
7 1
CH2 サブレーダ画像取得エラー
CH2 に接続されているサブレーダの画像信号が検出されない。
7 2
FGB 通信エラー
主制御部(MCB)と画像記録部(FGB)との LAN 通信が不可
7 3
FGB セットアップデータ受信エラー
主制御部(MCB)が画像記録部(FGB)のセットアップデー
タ受信に失敗
7 4
FGB 制御エラー
主制御部(MCB)と画像記録部(FGB)との LAN 通信が失敗
7 5
NWP-46 ファンエラー
レーダ I/F ユニット:NWP-46 に内蔵されるファンの回転が停止
7 6
FGB リアルタイムモニタデータの送信エラー
画像記録部(FGB)の送信先 IP アドレスが未登録
8 0 RMB
RMB 通信エラー
主制御部(MCB)とリモートメンテナンス部(RMB)との LAN
通信が不可
8 1
RMB 制御エラー
主制御部(MCB)とリモートメンテナンス部(RMB)との LAN
通信が失敗

26
第1章 操作説明

表 9. シリアルデータ受信エラー コード・装置変換表 (1/2)


下表で定義されていない装置を接続している場合には、装置コードが存在しませんので、接続している
CH 番号が表示されます。コード:01~32 が表示されている時には接続 CH を表示していることになり
ます。
ALARM DETAIL Equipment
SYSYTEM CODE
6 0/1 4 1 GPS
4 2 AIS
4 3 スピードログ
4 4 シャイロコンパス
4 5 オートパイロット
4 6 舵角指示器
4 7 測深器 (Bow)
4 8 風向・風速計
4 9 エンジンテレグラフ
5 0 エンジンリモコン
5 1 ECDIS
5 2 スラスタ
5 3 スラスタ Bow1
5 4 スラスタ Bow2
5 5 スラスタ Stern1
5 6 スラスタ Stern2
5 7 船体ストレスモニタ
5 8 レーダ
5 9 測深器 (Stern)
6 0 接点信号入力器 1 (VDR オプション)
6 1 接点信号入力器 2 (VDR オプション)
6 2 接点信号入力器 3 (VDR オプション)
6 3 接点信号入力器 4 (VDR オプション)
6 4 接点信号入力器 1+A/D コンバータ付 (VDR オプション)
6 5 接点信号入力器 2+A/D コンバータ付 (VDR オプション)
6 6 接点信号入力器 3+A/D コンバータ付 (VDR オプション)
6 7 接点信号入力器 4+A/D コンバータ付 (VDR オプション)
6 8 NAV-I/F ユニット (VDR オプション)
6 9 予備
7 0 外部 NSK ユニット (NCT-27)
7 1 メイン GPS+サブ GPS(切替器経由)
7 2 サブ GPS(メイン GPS と別 CH 接続)
7 3 磁気コンパス
3 3 NSK-I/F ボード 船首方位信号入力 (VDR オプションボード)
3 4 NSK-I/F ボード 船速信号入力 (VDR オプションボード)

27
第1章 操作説明

1.6.3 操作表示器の操作方法(NSK モード)

NSK モードはオプションの NSK-I/F ボードを増設した場合にのみ使用します。


NSK-I/F ボードは、船首方位データをシンクロ信号/ステップ信号で入力する場合や、船速デー
タをパルス信号で入力する場合に必要となります。
NSK-I/F ボードを無効にしている場合には、操作表示器が NSK モードになることはありません。

1. 船首方位の初期値を入力する場合
1) 記録制御機(RCU)の電源を ON します。
2) 船首方位初期値の未入力アラームとしてブザーが鳴動します。
3) ALARM LED と 4 桁の ERROR コード LED(“01__”及び“6033”表示)が点滅します。
4) ALARM ACK スイッチを押してください。ブザーの鳴動が止まります。
5) MODE スイッチを押して、NSK モードに変更してください。
6) NSK モードになると HEADING LED が点滅します。船首方位初期値を入力するまで点滅
します。
7) シャイロ表示器に表示されている船首方位値を確認します。
8) 船首方位値を操作表示器に入力します。
・ERROR コード LED の点滅している桁が入力対象ですので、左右キーを押して入
力対象桁が点滅するようにします。
・入力したい数値になるよう上下キーで表示値を変更します。
・上記手順を繰り返し、ERROR コード LED に船首方位の初期値を表示します。
9) 4 桁の数値を入力後、ENTER スイッチを押します。表示値が船首方位の初期値として
VDR に登録されます。
10) HEADING LED が点灯に変わります。
11) ジャイロコンパスの船首方位表示値が変化しても、操作表示器の ERROR コード LED は
ほぼ同じ値(VDR で記録する船首方位値)を表示します。

2. NSK モードから通常モードに戻す場合
下記の何れかの手順で通常モードに戻ります。
・ MODE スイッチを押します。
・ 5 分経過すると自動で通常モードに戻ります。

28
第2章 仕様

2.1 保護カプセル (Protective Capsule Unit: PCU) NDH-316A/316

1) 機能:
回収用保護カプセル内の記録媒体へ運航データ・船体データ・船橋会話デー
タ・VHF 通信会話データ・レーダ指示器表示画像データを記録します。
保護カプセルには水中音響ビーコンが取り付けられています。カプセル水没
時には、この水中音響ビーコンが作動し、カプセル探索用に音響ビーコン信
号を出力します。

2) 性能:
1) インターフェイス:
a) 規格: IEEE802.3(10Base-T/100Base-T)
b) プロトコル: TCP/IP
2) データ記録容量: 2.0GB フラッシュメモリ(12 時間ループ)
3) データ別記録周期:
a) センサデータ: センサからの入力による(通常は 1 秒)
b) 音声データ: リアルタイム連続(1 分毎)
c) 画像データ: 1画像/15 秒
4) 水中音響ビーコン:
a) 動作周波数: 37.5kHz±1kHz
b) 作動時間: min. 30 日
c) 通達距離: 1800m ~ 3600m (環境により変動します。

d) ビーコンバッテリ寿命: 5年

3) 環境:
下記の環境下で、最終記録メディアの破損、データの欠損が無いこと。
1) 耐ショック:11m ミリ秒周期の半サインカーブパルス 50G
2) 耐貫通: 質量 250kg・直径 100mm のピン形状物体を 3m の高さから落下
3) 耐火: 260℃の火炎下で 10 時間/1100℃の火炎下で 1 時間
4) 耐深海水圧:60Mpa(水深 6000m の水圧)
一般環境条件:
1) 動作温度: -25℃ ~ +55℃
2) 保存温度: -55℃ ~ +70℃
3) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

4) 一般仕様:
1) 電源電圧 : DC19.5V ~ 36.5V
2) 消費電力: 3W
3) 寸法 : NDH-316A 186 (W) x 209 (D) x 217 (H) mm
NDH-316 182 (W) x 206 (D) x 218 (H) mm
4) 質量 : NDH-316A 7.9Kg
NDH-316 8.7Kg
5) 塗装色 : 蛍光オレンジ

29
第2章 仕様

2.2 記録制御機 (Recording Control Unit: RCU) NDV-1800

2.2.1 操作表示部 (内部パネル)

1) 機能:
1) スイッチ操作:
a) 記録停止: 保護カプセルへのデータ記録停止
b) 記録開始: 保護カプセルへのデータ記録開始
c) CF カード記録停止: CF カードへのデータ記録停止
(CF カードを取り出せるようにします。)
d) CF カード記録保全: CF カード内記録データの保全と解除

2) LED 表示:
a) 記録状態: 記録中/記録停止 表示
b) CF カード状態: 記録中/記録停止(取出可)/記録保全 表示
c) CF カードメディアエラー: CF カード異常表示

2.2.2 データ処理部 (Data Processor Unit)

1) 機能:
1) 運航データ・船体データの保護カプセルへの記録制御
2) IEC61162-1/2 による、運航データ・船体データを収集します。収集データは、
次の通りです。:[IEC61996 4.6 及び IMO A.861 5.4 による]
a) 日付,時刻(UTC)
b) 電子測位機器による船位
c) 船速(対地・対水)
d) 船首真方位又はマグネット磁針船首方位
e) キール下水深余裕(Under Keel Clearance)
f) 船橋内主要アラーム
g) 操舵指令と応答データ
h) エンジン指令と実効データ
i) ハル開閉状況(RO-RO 船・フェリーのみ)
j) 水密扉・防火扉の状況
k) 船首加速度と船体応力データ
(IMO により船体応力計の搭載が義務付けられている船舶のみ)
l) 風向風速データ(装備されている場合のみ)
3) 船橋会話データ・VHF 通信会話データ・レーダ指示器表示画像データの収
集と保護カプセル及び CF カードへの記録制御
4) CF カードへのバックアップ記録と保全
5) システムの動作管理・制御

30
第2章 仕様

2) 性能:
1) 保護カプセルとの通信:
a) 規格: IEEE802.3(10Base-T/100Base-TX)
b) プロトコル: TCP/IP

2) センサデータ入力:
a) 入力チャネル: 最大 32CH
b) 入力信号規格: IEC61162-1/2 (RS-422)
c) 記録周期: センサからの入力による(通常は 1 秒)
3) 船橋会話入力:
a) 入力チャンネル: 9 チャンネルまで
b) 入力感度: 6kHz
c) 記録周期: リアルタイム連続(1file/分)
4) VHF 通信会話入力:
a) 入力チャンネル: 3 チャンネルまで
b) 入力感度: 3.5kHz
c) 入力レベル: 0 dBm 600 オーム 平衡
d) 記録周期: リアルタイム連続(1file/分)
5) レーダ指示器表示画像入力:(No1.レーダ X バンドを推奨)
a) 入力チャンネル:2 チャンネル
2 チャンネル接続時には切替記録
(JRC 製レーダにて稼働レーダの自動選択可)
* 詳細は、2.2.8 項を参照
b) 入力インターフェイス: アナログ RGB Hs Vs
・RGB: 0.7Vp-p ・Hs: TTL ・Vs: TTL
c) 解像度: 640×350 ~ 1600×1200 ピクセル 60 ~ 85 Hz
(VESA DMTS 準拠)
(1600×1200 ピクセルは 60Hz のみ対応可)
d) 記録周期: 1画像/15 秒
6) 保護カプセル記録データのバックアップ
a) メディア: CF カード (カードアダプタ標準添付)
b) データ容量: 2GB
7) 停電処理
a) 停電時記録時間: 船橋内会話のみ2時間
(停電時は、船橋内会話以外のデータは、記録しません。)
b) 停電復旧所要時間: 1 分以内
(停電復旧後、船橋内会話のみの記録から全データ記録に
切り替わる時間)
8) GPS 切替信号
a) 信号 I/F: 接点信号(無電圧接点)
(外部接点入力と兼用)
b) 切替: 記録 GPS 装置指定(OPEN/CLOSE)

31
第2章 仕様

9) レーダ切替信号 (但し、JMA-9900、900M、5300 レーダのみ対応)


a) JRC 製レーダ信号 I/F: IEC61162-1(RS-422)
b) JRC 製レーダ切替: メインレーダの稼働状態を監視して切替
c) 他社製レーダ信号 I/F: 接点信号(無電圧接点)
(外部接点入力と兼用)
d) 他社製レーダ切替: 記録レーダ装置指定(OPEN/CLOSE)
10) 外部接点入力(無電圧接点)
a) 入力数:最大 3 接点(レーダ及び GPS の選択入力信号と兼用)
b) 出力センテンス:メーク時とオープン時のセンテンスを登録

2.2.3 電源ユニット (Power Supply Unit: PSU)

1) 機能:
a) 記録制御機および保護カプセルへ電源供給を行います。
b) 停電時に記録制御機、マイクユニットおよび保護カプセルへ 2 時間
電源供給を行います。

2) 性能:
a) 入力電源: AC100V~AC120V±10% 1-phase 50/60Hz±5%
AC200V~AC240V±10% 1-phase 50/60Hz±5%
(自動切替)
b) 出力電源: DC5V、12V、24V
c) 最大出力容量: 140VA
d) 電池容量: DC24V 5Ah
e) バッテリ期待寿命: max. 4 年
(使用温度環境 25℃、負荷率 70%の場合)

2.2.4 外部インターフェース(External Interface)

1) 外部警報出力(無電圧接点)
a) 外部ブザー用出力(ノーマルオープン/クローズ)
接点定格: DC24V 1A 以下
AC125V 0.5A 以下
b) 外部警報ランプ用出力(ノーマルクローズ/オープン)
接点定格: DC24V 1A 以下
AC125V 0.5A 以下

2.2.5 環境条件
1) 動作温度範囲: -15℃ ~ +55℃
2) 動作温湿度: +40℃ 93% 但し、結露無きこと
3) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

32
第2章 仕様

2.2.6 一般仕様
1) 入力電源: AC100V~AC120V±10% 1-phase 50/60Hz±5%
AC200V~AC240V±10% 1-phase 50/60Hz±5%
2) 消費電力: (カプセル、操作表示器、マイクの消費電力を含む)
90VA: バッテリ充電時
50VA: 通常時(バッテリ満充電)
3) 寸法: 419.5(w) x 250(d) x 480(h) mm
4) 質量: 23.0kg
5) 色 : N7 半ツヤ シボ

2.2.7 NSK インターフェース部(オプション)

1) 機能:
1) シンクロ/ステップ信号で入力される船首方位データ、パルス信号で入力さ
れる船速データをデジタル変換し、IEC61162-1 センテンスとして記録する
2) 性能:
1) 入力信号:
a) シンクロ信号(船首方位)
レシオ: 360X、 180X、 90X、 36X、 1X
プライマリ電圧: AC50~115V、50/60Hz
セカンダリ電圧: AC20~90V、50/60Hz
b) ステップ信号(船首方位)
レシオ: 360X、180X、90X、36X、1X
電圧: DC24V/35V/50V/70V
c) パルス信号(船速)
NM 当たりのパルス数: 200P/400P/100P/160P
I/F: フォトカプラ/接点信号(無電圧接点)
2) 記録信号:
a) データ形式: IEC61162
b) 船首方位: HDT センテンスフォーマット
c) 船速: VBW センテンスフォーマット

2.2.8 レーダ切替記録機能
レーダ装置を 2 台接続する場合、記録画像の切替仕様は以下の通りです。

1) 機能:
1) 稼働しているレーダ装置の画面を自動判定して記録します。
自動判定は、JRC 製レーダ装置が出力する IEC61162 準拠のオリジナルセン
テンスから空中線の動作状態を監視することで実施されます。
2) 切替記録機能は、JRC 製レーダを接続した場合にのみ有効となります。
対象となるレーダ装置は現行モデルからです。旧型は対象外となります。
(JMA-5300、JMA-9900、JMA-900M)

33
第2章 仕様

2) 性能:
JRC 製以外のレーダ装置を接続する場合でも、2 台接続できるよう切替記録機能を
サポートしています。(下記 2)、3)参照) 但し、通常の運用条件では記録対象の
レーダ装置を自動判定することができないため、2 台接続での切替記録は推奨しま
せん。
JRC 製以外のレーダ装置を接続して切替記録する場合には、下記仕様を十分に理解
して、稼働レーダの画像が記録されるよう運用してください。

1) 現行 JRC 製レーダ装置(JMA-5300、JMA-9900、JMA-900M)
X-band レーダ装置より出力される IEC61162 準拠センテンスで空中線の稼
働状況を監視します。X-Band レーダ装置の空中線が稼働している場合には、
接続している CH1 のレーダ画像を記録します。空中線が稼働していない場
合には、CH2 に接続されているレーダ画像を記録します。

2) 切替 SW 接続
下記仕様の切替 SW を記録制御機の接点信号入力部(TB406 の PI_1、PI_2)
に接続することで、記録モードを選択することができます。
・AUTO モード: 画像の同期信号が出力されている CH の画像を自
動選択して記録します。CH1、CH2 の両方から同
期信号が出力されている場合には、CH1 を優先
して記録します。
・CH1 記録モード: CH1 の画像を強制記録します。
CH1 より画像信号が入力されていない場合には、
画像データは記録されません。
・CH2 記録モード: CH2 の画像を強制記録します。
CH2 より画像信号が入力されていない場合には、
画像データは記録されません。

PI_1(TB406) PI_2(TB406) RADAR Recording Mode


OPEN OPEN AUTO
OPEN CLOSE CH1 record
CLOSE OPEN CH2 record

AUTO モードで運用した場合、使用しないレーダ指示器の電源を OFF して、


画像信号を出力しないようにすれば、記録対象の CH に切替られますが、
レーダ装置をスタンバイ状態にしただけでは画像信号の出力が停止されま
せん。結果として、CH1 より受信される x-band のレーダ画像を常に記録す
ることになりますので、x-band をスタンバイにすると、エコーのない x-band
のレーダ画面が記録されます。

3) 常時 AUTO モード
切替 SW を接続せず、レーダ装置を 2 台接続した場合には、常時 AUTO モ
ードで動作します。

34
第2章 仕様

2.3 操作表示器 (Operation Panel unit) NCG-169

1) 機能:
1) 操舵室での可視、可聴による VDR のエラー警報
2) エラーコードによりエラー要因を表示
3) 船首方位の初期値入力

2) 性能:
1) 形状: 盤埋め込み型又は壁掛け型
2) 電源: 記録制御機から DC12V を供給
3) 表示: アラーム表示としての LED 点滅、点灯
4 桁数値 LED によるエラーコード表示
アラームとしてのブザー(ACK 応答により停止)
4) 操作: アラームへの応答操作
LED の輝度調整

3) NSK 機能: (NSK-I/F ボード(オプション)を増設した場合のみ)


1) 操作: 船首方位の初期値入力
2) 表示: 船首方位値のリアルタイム表示

4) 環境条件:
1) 動作温度範囲: -15℃ ~ +55℃
2) 動作温湿度: +40℃ 93% 但し、結露無きこと
3) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

5) 一般仕様:
1) 寸法: 145(w) x 50(d) x 165(h) mm
2) 質量: 0.3kg
3) 色 : N4 半ツヤ シボ

2.4 マイクユニット (Microphone Unit) NVT-161

1) 機能:
船橋内の会話、警報音等を収録します。

2) 性能:
1) 形状: 天井埋込型・露出型
2) タイプ: エレクトレットコンデンサ型
3) 指向特性: 半球無指向性
4) 集音範囲: 半径 2.5m
5) 供給電源: DC12V(ファントム電源)
6) テスト機能: マイクテスト用スピーカ内蔵

35
第2章 仕様

3) 環境条件:
1) 動作温度範囲: -15℃ ~ +55℃
2) 動作温湿度: +40℃ 93% 但し、結露無きこと
3) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

4) 一般仕様:
1) 寸法: 145(w) x 50(d) x 165(h) mm
2) 質量: 0.2 kg
3) 色 : N4 半ツヤ シボ

2.5 防水中継箱 (Connection Box) NQE-3163

1) 機能:
記録制御機と保護カプセルを接続するための防水型中継箱

2) 性能:
1) 接続 I/F: 内蔵端子台

3) 環境条件:
1) 動作温度範囲: -25℃ ~ +55℃
2) 動作温湿度: +40℃ 93% 但し、結露無きこと
3) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G
4) 防水等級: IPx6

4) 一般仕様:
1) 寸法: 170(w) x 176(d) x 87(h) mm
2) 質量: 1.3 kg
3) 色 : 7.5BG 7/2

2.6 防水マイクユニット (Waterproof Microphone Unit:オプション) NVT-162

1) 機能:
ウイングの会話を収録します。

2) 性能:
1) 形状: 壁掛け型
2) タイプ: エレクトレットコンデンサ型
3) 指向特性: 半球無指向性
4) 集音範囲: 半径 2.5m
5) 供給電源: DC12V(ファントム電源)
6) テスト機能: マイクテスト用スピーカ内蔵

36
第2章 仕様

3) 環境条件:
1) 動作温度範囲: -25℃ ~ +55℃
2) 動作温湿度: +40℃ 93% 但し、結露無きこと
3) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G
4) 防水性能: IPX6

4) 一般仕様:
1) 寸法: 126(w) x 93(d) x 110(h) mm
2) 質量: 1.2kg
3) 色 : N7 半ツヤ

2.7 接点信号入力器 64CH (Digital Signal Converter:オプション) NCT-72

1) 機能:
接点信号で出力される主警報情報を収集し、シリアルデータ(IEC61162-1)
に変換して出力します。

2) 性能:
a) 接点信号入力チャネル: 無電圧接点信号
最大 64CH 入力
b) 接点信号 I/F:
1)プルアップ電圧: DC+12V
2)接点論理: ノーマル OPEN/ノーマル CLOSE(設定により変更可)
c) 通信ポート: 記録制御機と接続
d) 出力センテンス: IEC61162-1 準拠

3) A/D 変換性能(オプション)
: A/D 変換ボード(CEF-60)を内蔵した場合
a) アナログ信号入力チャネル: 最大 8CH 入力
b) アナログ信号 I/F:
1)電圧レンジ: +/-500mV、 +/-5V、 +/-10V
2)電流レンジ: +/-20mA
c) 通信ポート: 記録制御機と接続(接点信号と共通)
d) 出力センテンス: IEC61162-1 準拠 XDR センテンス

4) 環境条件:
a) 動作温度範囲: -15℃ ~ +55℃
b) 動作温湿度: +40℃ 93% 但し、結露無きこと
c) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

5) 一般仕様:
a) 入力電源: AC100V~AC120V±10% 1-phase 50/60Hz±5%
AC200V~AC240V±10% 1-phase 50/60Hz±5%

37
第2章 仕様

b) 消費電力: 25VA
c) 寸法: 300(w) x 130(d) x 420(h) mm
d) 質量: 5kg
e) 色 : N7 半ツヤ

2.8 接点信号入力器 16CH (Digital Signal Converter:オプション) NCT-63

1) 機能:
接点信号で出力される主警報情報を収集し、シリアルデータ(IEC61162-1)
に変換して出力します。

2) 性能:
a) 接点信号入力チャネル: 無電圧接点信号
最大 16CH 入力
b) 接点信号 I/F:
1)プルアップ電圧: DC+12V
2)接点論理: ノーマル OPEN/ノーマル CLOSE(設定により変更可)
c) 通信ポート: 記録制御機と接続
d) 出力センテンス: IEC61162-1 準拠

3) A/D 変換性能(オプション)
: A/D 変換ボード(CEF-60)を内蔵した場合
a) アナログ信号入力チャネル: 最大 8CH 入力
b) アナログ信号 I/F:
1)電圧レンジ: +/-500mV、 +/-5V、 +/-10V
2)電流レンジ: +/-20mA
c) 通信ポート: 記録制御機と接続(接点信号と共通)
d) 出力センテンス: IEC61162-1 準拠 XDR センテンス

4) 環境条件:
a) 動作温度範囲: -15℃ ~ +55℃
b) 動作温湿度: +40℃ 93% 但し、結露無きこと
c) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

4) 一般仕様:
a) 入力電源: AC100V~AC120V±10% 1-phase 50/60Hz±5%
AC200V~AC240V±10% 1-phase 50/60Hz±5%
b) 消費電力: 25VA
c) 寸法: 300(w) x 130(d) x 230(h) mm
d) 質量: 2.9kg
e) 色 : N7 半ツヤ

38
第2章 仕様

2.9 レーダ I/F ユニット (Radar Interface Unit:オプション) NWP-46

1) 機能:
画面解像度が UXGA(1600×1200)のレーダを接続する場合に使用します。
高解像度の RGB 信号は VDR までケーブルを延長して接続することはできま
せん。
本ユニットは画像記録部をレーダ装置の近くに設置するための装置です。

2) 性能:
1) 基本性能: 記録制御機のレーダ画像入力仕様同等
2) 通信 I/F: 記録制御機と Ethernet 接続

3) 環境条件:
1) 動作温度範囲: -15℃ ~ +55℃
2) 動作温湿度: +40℃ 93% 但し、結露無きこと
3) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

4) 一般仕様:
1) 入力電源: AC100V~AC120V±10% 1-phase 50/60Hz±5%
AC200V~AC240V±10% 1-phase 50/60Hz±5%
2) 消費電力: 10VA
3) 寸法: 255(w) x 160(d) x 72(h) mm
4) 質量: 1.5kg
5) 色 : N4 半ツヤ

2.10 使用環境条件

2.10.1 使用条件
1) 使用条件:
1) 対象船舶: 国際航海に従事する 3000G/T 以上の商船
国際航海に従事する 150G/T 以上の旅客船

2) 各ユニット設置場所:
1) 保護カプセル (Protective Capsule Unit) :船橋上外部甲板
2) 防水中継箱(Connection Box) :船橋上外部甲板
3) 記録制御機(Recording Control Unit) :操舵室(あるいは電機室)
4) 操作表示器(Operation Panel Unit) :操舵室
5) マイクユニット(Microphone Unit) :操舵室内天井、又は壁面
6) 防水マイク(Waterproof Microphone Unit) :ウイング
7) 接点信号入力器(Digital Signal Converter) :船橋(あるいは電機室)
8) レーダ I/F ユニット(Radar Interface Unit) :レーダ側

39
第2章 仕様

3) 設置方法:
1) 保護カプセル(Protective Capsule Unit) :デッキマウント
2) 防水中継箱(Connection Box) :デッキマウント
3) 記録制御機(Recording Control Unit) :壁掛け
4) 操作表示器(Operation Panel Unit) :壁埋め込み又は壁露出
5) マイクユニット(Microphone Unit) :天井埋め込み又は、壁、天井露出
6) 防水マイク(Waterproof Microphone Unit) :壁掛け
7) 接点信号入力器(Digital Signal Converter) :壁掛け
8) レーダ I/F ユニット(Radar Interface Unit) :レーダへ取付

2.10.2 電源環境条件

1) AC 電源入力範囲
a) AC100/110/115/120V ±10%
b) AC200/220/240V ±10%

2) AC 電源周波数変動範囲
a) 50Hz±5%
b) 60Hz±5%

2.10.3 環境条件

1) 屋外装置: (保護カプセル、防水マイク)

1) 動作温度範囲: -25℃ ~ +55℃


2) 保存温度: -25℃ ~ +70℃
3) 動作温湿度: +40℃ 93% 但し、結露無きこと
4) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

2) 屋内装置: (記録制御機、操作表示器、マイクユニット、オプションユニット)

1) 動作温度範囲: -15℃ ~ +55℃


2) 動作温湿度: +40℃ 93% 但し、結露無きこと
3) 振動: 2Hz ~ 13.2Hz ±1.0mm
13.2Hz ~ 100Hz 0.7G

40
第3章 保守点検

警 告
お客様による内部の点検・修理は絶対に行わないでください。
専門整備員以外による点検・修理は火災・感電の原因となります。
内部の点検・修理は当社営業部またはお近くの支社・支店・営業所または当社
代理店にご依頼ください。

注 意
表面を掃除するときは、シンナーやベンジンなどの有機溶剤を使用しないでく
ださい。表面の塗装を痛める原因となります。
表面の掃除はチリ、ゴミを取り除き、清潔な布で乾拭きするようにしてくださ
い。

3.1 日常の保守

機器は保守の適否により寿命が非常に左右されるものです。常に最良の動作条件を保つため
には、平常より定期的に点検を行うようにしてください。これにより故障を早期に発見した
り未然に防ぐことができます。

3.1.1 清掃

注 意
海水や淡水が本装置にかかった場合はすぐにふき取ってください。故障、操作
不良の原因となることがあります。

本装置の汚れは柔らかな布に中性洗剤を滴らない程度に染み込ませ、軽くふき取ってくだ
さい。

41
第3章 保守点検

3.1.2 電池の有効期限の確認
記録制御機、及びカプセルの上部に取り付けられている水中音響ビーコンの電池の有効期
限を確認してください。有効期限が近くになりましたら、当社営業部またはお近くの支
社・支店・営業所または当社代理店へ定期交換を依頼してください。

3.2 定期点検

年に一度は本装置の内部および電源の接続、他機器との接続状態の点検をお奨めします。
尚、定期点検は有料となります。毎年、年次検査が義務づけられています。当社営業部また
はお近くの支社・支店・営業所または当社代理店へ定期点検を依頼してください。

42
第3章 保守点検

3.3 トラブルシューティング

本機の動作がおかしい場合は、以下の項目を元にチェックしてください。各項目に原因、対
策が記してありますので、指示に従って行ってください。
それでも解決しない場合、また以下の項目以外でおかしい箇所がありましたら、当社の営業
部またはお近くの支社・支店・営業所または当社代理店にご連絡ください。

3.3.1 記録制御機 Recording Control Unit (NDV-1800)

(1) 電源ユニット Power Supply Unit (NBL-327)

現象 原因 対策
POWER LED が点 配電盤から電源が供給されてい
配電盤を点検してください。
灯しない。 ない。
POWER スイッチを ON してい POWER スイッチを ON してくださ
ない。 い。
電源ユニットの AC 電源ヒューズを点
AC 電源ヒューズが溶断してい
検し、もし溶断している場合は、予備
る。
ヒューズと交換してください。
電源ユニットが故障している。 当社へご相談ください。
BATTERY OP.
配電盤から電源が供給されてい
LED が点灯する。 配電盤を点検してください。
ない。
電源ユニットの AC 電源ヒューズを点
AC 電源ヒューズが溶断してい
検し、もし溶断している場合は、予備
る。
ヒューズと交換してください。
BATTERY
バッテリケーブルが接続されて
ABNORMAL LED 当社へご相談ください。
いない。
が点灯する。
バッテリヒューズが溶断してい
当社へご相談ください。
る。
バッテリの交換期限を確認し、過ぎて
バッテリが劣化している。
いる場合には当社へ相談ください。
FAN
ABNORMAL. ファンが停止している。 当社へご相談ください。
LED が点灯する。

43
第3章 保守点検

(2) データ処理部 Data Processor Unit (NDL-46)

現象 原因 対策
REC LED が点灯 記録制御機の電源が入っていな
配電盤を点検してください。
しない。 い。
電源ユニットの電源を入れてくださ
保護カプセルに電源が供給され
い。
ていない。
主制御部(MCB)の REC START スイ
保護カプセルへのデータの記録
ッチを押してデータの記録を再開さ
を手動で停止している。
せてください。
記録制御機と保護カプセル間の
防水中継箱を点検してください。
配線異常

記録制御機不良 記録制御機を再起動しても復旧しな
保護カプセル不良 い場合は、当社へご相談ください。
CARD LED が 点 主制御部(MCB)の CF カードをイジ
CARD STOP スイッチを押した
灯しない。 ェクトボタンにより一度、抜き取り、
まま放置している。
再度差し込んでください。
CF カードが抜き取られたままに 主制御部(MCB)のカードスロットに
なっている。 CF カードを差し込んでください。
記録制御機を再起動しても復旧しな
記録制御機不良
い場合は、当社へご相談ください。
MEDIA LED が点 主制御部(MCB)の CF カードをイジ
滅する。 CF カード不良 ェクトボタンにより一度、抜き取り、
再度差し込んでください。
CF カードが抜き取られたままに 主制御部(MCB)のカードスロットに
なっている。 CF カードを差し込んでください。
記録制御機を再起動しても復旧しな
記録制御機不良
い場合は、当社へご相談ください。
CARD LED と 事故時のデータの不注意による上書
MEDIA LED が きを防止しており、正常です。
点滅する。 下記の場合には、CF カードの保全状
態を解除し、再び記録を開始できま
す。
CF カード内の記録データを保全 ・誤って保全した場合
している。 ・関係官庁に事故データの引渡しを
完了した場合

主制御部(MCB)の REC START ボタ


ンを CARD LED が点灯するまで(約
10 秒間)押してください。

44
第3章 保守点検

3.3.2 操作表示器 Operation Panel Unit (NCG-169)

現象 原因 対策
全 LED が点滅し、 ソフトウェアが異常動作してい
記録制御機を再起動してください。
ALARM ブザー鳴 る。
動する。
記録制御機と操作表示器間の配 記録制御機と操作表示器間の配線を
線異常 点検してください。
REC LED が点灯 記録制御機の電源が入っていな
配電盤を点検してください。
しない。 い。
電源ユニットの電源を入れてくださ
保護カプセルに電源が供給され
い。
ていない。
主制御部(MCB)の REC START スイ
保護カプセルへのデータの記録
ッチを押してデータの記録を再開さ
を手動で停止している。
せてください。

記録制御機と保護カプセル間の
防水中継箱を点検してください。
配線異常

記録制御機不良 記録制御機を再起動しても復旧しな
保護カプセル不良 い場合は、当社へご相談ください。
エラーコード 船首方位の初期値が入力されて
“01__”が点灯 初期値を入力してください。
いません。
エラーコード 事故時のデータの不注意による上書
“03__”が点灯 きを防止しており、正常です。
下記の場合には、CF カードの保全状
態を解除し、再び記録を開始できま
す。
CF カード内の記録データを保 ・誤って保全した場合
全している。 ・関係官庁に事故データの引渡しを
完了した場合

主制御部(MCB)の REC START ボ


タンを CARD LED が点灯するまで
(約 10 秒間)押してください。
エラーコード 主制御部の CF カードをイジェクトボ
“31__”が点灯 CARD STOP スイッチを押した
タンにより一度、抜き取り、再度差し
まま放置している。
込んでください。
CF カードが抜き取られたまま 主制御部のカードスロットに CF カー
になっている。 ドを差し込んでください。
記録制御機を再起動しても復旧しな
記録制御機不良
い場合は、当社へご相談ください。
エラーコード 主制御部(MCB)の CF カードをイジ
“32__”が点灯 CF カード不良 ェクトボタンにより一度、抜き取り、
再度差し込んでください。

記録制御機を再起動しても復旧しな
記録制御機不良
い場合は、当社へご相談ください。

45
第3章 保守点検

現象 原因 対策
エラーコード 保護カプセルと記録制御機の構 REC START スイッチを 10 秒間押して
“00__”が点灯 成情報が一致していない。 ください。

記録制御機と保護カプセル間の
防水中継箱を点検してください。
配線異常

記録制御機不良 S 記録制御機を再起動しても復旧しな
保護カプセル不良 い場合は、当社へご相談ください。
エラーコード 記録制御機を再起動しても復旧しな
“20__”が点灯 保護カプセル不良
い場合は、当社へご相談ください。
エラーコード 一時的にエラーが発生する場合があ
“21__”が点灯 保護カプセルの記録処理でエラ りますが、通常長くとも2日で自動的
ー発生 にエラーは、解除されます。
2日経過してもエラーが解除されな
い場合は、当社へご相談ください。
エラーコード 記録制御機と保護カプセル間の
“23__”が点灯 防水中継箱を点検してください。
配線異常

記録制御機不良 記録制御機を再起動しても復旧しな
保護カプセル不良 い場合は、当社へご相談ください。
エラーコード エラーコードで指定されたセンサ装
“60 * *”が点灯 センサ不良
置を点検してください。

記録制御機-エラーコードで指定さ
記録制御機-各センサ装置間の
れたセンサ装置間の配線を点検して
配線不良
ください。

記録制御機不良 記録制御機を再起動しても復旧しな
い場合は、当社へご相談ください。
エラーコード 主制御部(MCB)のセットアッ 記録制御機を再起動しても復旧しな
“61 * *”が点灯 プが間違っています。 い場合は、当社へご相談ください。

エラーコード 音声ボード不良 マイクユニットと記録制御機間の配


“5 *__”が点灯 マイクユニット不良 線を点検してください。
マイクユニットの周辺で大きな騒音
騒音によるアラーム が無い状態で、記録制御機を再起動し
てください。

エラーコード 記録制御機の入力電源を点検してく
“10 * *”が点灯 停電中
ださい。
配電盤から電源が供給されてい
配電盤を点検してください。
ない。
電源ユニットの AC 電源ヒューズを点
AC 電源ヒューズが溶断してい
検し、もし溶断している場合は、予備
る。
ヒューズと交換してください。
エラーコード
“11__”が点灯 ファンが停止している。 当社へご相談ください。

46
第3章 保守点検

現象 原因 対策
エラーコード 記録制御機を再起動しても復旧しな
“30__”/“35__” い場合は、当社へご相談ください。
“36__”/“37__” 主制御部不良
“38__”が点灯

エラーコード GPS が故障したか、記録制御機 GPS 装置を点検してください。


“33__”が点灯 のセットアップが間違っていま GPS に異常が無い場合は、当社へご相
す。 談ください。

エラーコード 主制御部(MCB)に実装されて バッテリ寿命による交換が必要なこ


“34__”が点灯 いる時計 IC バックアップ用のバ とを当社へ連絡してください。
ッテリの電圧が低下していま
す。
エラーコード 記録制御機を再起動しても復旧しな
“40_”/“41_” 音声記録部不良 い場合は、当社へご相談ください。
“42_”が点灯

エラーコード レーダからの画像信号が入力さ レーダ画面を確認してください。


“70_”/“71_” れていません。 画面が表示されている場合にはレー
が点灯 70__:CH1 ダ-記録制御機間の配線を点検して
71__:CH2 ください。

エラーコード 記録制御機の扉を開けて、画像記録部
“72_”が点灯 画像記録部(FGB)と主制御部 (FGB)と主制御部(MCB)間の配
(MCB)間の配線異常 線を点検してください。

画像記録部(FGB)の故障 記録制御機を再起動しても復旧しな
主制御部(MCB)の故障 い場合は、当社へご相談ください。

エラーコード 記録制御機を再起動しても復旧しな
画像記録部(FGB)のセットア
“73_”/“76_” い場合は、当社へご相談ください。
ップが間違っています。
が点灯
エラーコード 記録制御機を再起動しても復旧しな
“74_”が点灯 画像記録部(FGB)の故障 い場合は、当社へご相談ください。

エラーコード NWP-46 のファンが停止してい 当社へご相談ください。


“75_”が点灯 ます。
エラーコード 電源部(PSU)と主制御部(MCB) 記録制御機を再起動しても復旧しな
“12_”が点灯 間の制御ケーブルが異常です。 い場合は、当社へご相談ください。
エラーコード 記録制御機の扉を開けて、リモートメ
リモートメンテナンス部(RMB)
“80_”が点灯 ン テ ナ ン ス 部 ( RMB ) と 主 制 御 部
と主制御部(MCB)間の配線異
(MCB)間の配線を点検してくださ

い。
リモートメンテナンス部(RMB) 記録制御機を再起動しても復旧しな
の故障 い場合は、当社へご相談ください
主制御部(MCB)の故障
エラーコード リモートメンテナンス部(RMB) 記録制御機を再起動しても復旧しな
“81_”が点灯 の故障 い場合は、当社へご相談ください。

47
第3章 保守点検

ブランクページ

48
第4章 アフターサービス
4.1 修理を依頼される時

故障かな?と思ったら第3章を良くお読みの上、もう一度お調べください。
それでも異常が認められる場合には、使用を中止し、当社の営業部またはお近くの支社・支店・
営業所または当社代理店にご連絡ください。

1) 保証期間中の修理は、取扱説明書の説明・指示に従った正常な使用状態で故障し
た場合には、販売店または当社が無料修理致します。誤使用、過失または天災・
火災などの不可抗力によって生じた故障については有料となります。

2) 保証期間を過ぎている場合は、修理によって機能が回復可能な場合は、お客様の
ご要望により、有料で修理を承ります。

3) 連絡して頂きたいこと
a) 製品名・型名・製造年月日・製造番号
b) 異常の状況(出来るだけ詳しく:次ページの VDR 故障確認リストをご利用
ください。)
c) 事業所名又は機関名、所在地、電話番号

アフターサービスについてご不明な点は、お買い上げの販売店又は当社の営業部、お近くの支
社・支店・営業所へお問い合わせください。

お問い合わせ先
巻末の事業所一覧をご覧ください。

49
第4章 アフターサービス

VDR 故障確認リスト

(お願い)お手数ですが修理をご注文の際、下記の項目についてご確認、ご記入の上、注文先
へ連絡お願いします。尚、ご記入に際し、不明な項目がある場合は、本船にお問い
合わせ願い、出来る限り正確にご記入願います。

船名: 電話: FAX:


VDR 型名: 製造番号: 製造年月:

1) 下記の項目ついて番号順に確認し、
Yes 又は No のいずれか該当する方に○印を付けてください。
いずれにも該当しない場合と操作表示器に EROOR CODE 番号が表示されている場合は、末尾
の(7)に内容を具体的にご記入ください。
2) 確認項目の(1)、(2)にの確認結果が Yes の場合は、記録制御機のヒューズ及び船内配電盤を確認
願います。

番号 確認項目 確認結果
(1) 操作表示器の POWER LED は、点灯していない。 YES No
(2) 操作表示器の POWER LED は、点滅している。 YES No
(3) 操作表示器の RECORDING LED は、点灯していない。 YES No
(4) 操作表示器の ALARM LED は、点灯している。 YES No
(5) 操作表示器で操作ができない。 YES No
(6) 操作表示器に ERROR CODE が表示されている。 YES No
(7) 操作表示器に表示されている ERROR CODE を全て記入願います。

その他の内容

50
第4章 アフターサービス

4.2 廃棄について

4.2.1 本装置の廃棄について

本装置を廃棄する時は、廃棄する場所を管轄する地方自治体の条例または規則
に従って処理してください。ただしバッテリ、リチウム電池についてはその
まま廃棄しないで、当社の営業部又はお近くの支社・支店・営業所または当
社代理店に連絡ください。

4.2.2 使用済み電池の処置について

禁止事項:バッテリ及びリチウム電池
・ +-端子間のショート
・ 指定された用途以外の使用
・ 分解、改造、破棄
・ 火中投入及び加熱
・ 交換時期を過ぎての使用
漏液、発熱、火災、爆発、破壊、やけどなどの危険があります。

本装置の記録制御機(NDV-1800)にはバッテリが組み込まれています。
使用済みのバッテリは、リサイクルします。そのまま廃棄しないでください。
交換の際は、当社の営業部又はお近くの支社・支店・営業所または当社代理
店に連絡ください。

本装置の主制御部(CDJ-2304)、、リモートメンテナンス部(CDK-287)およ
び保護カプセルの水中ビーコンにはリチウム電池を使用しています。
交換の際の使用済みリチウム電池は、そのまま廃棄しないで、当社の営業部又
はお近くの支社・支店・営業所または当社代理店に連絡ください。

51
第4章 アフターサービス

ブランクページ

52
第5章 外形図
5.1 記録制御機 ( Recording Control Unit: NDV-1800 )

記録制御機 ( Recording Control Unit ) 外形図

53
第5章 外形図

5.2 操作表示器 ( Operation Panel Unit:NCG-169 )

NCG-169 VDR OPERATION PANEL

操作表示器 ( Operation Panel Unit ) 外形図

54
第5章 外形図

5.3 保護カプセル ( Protective Capsule Unit:NDH-316A/316 )

● NDH-316A

VOYAGE DATA RECORDER TA RECORDER


DO NOT OPEN T OPEN
REPORT TO AUTHORITIES AUTHORITIES

保護カプセル ( Protective Capsule Unit ) NDH-316A 外形図

55
第5章 外形図

● NDH-316

VOYAGE DATA RECORDER TA RECORDER


DO NOT OPEN T OPEN
REPORT TO AUTHORITIES AUTHORITIES

L3

保護カプセル ( Protective Capsule Unit ) NDH-316 外形図

56
第5章 外形図

5.4 防水中継箱 ( Connection Box:NQE-3163 )

防水中継箱 ( Connection Box ) 外形図

57
第5章 外形図

5.5 マイクユニット ( Microphone Unit:NVT-161 )

マイクユニット ( Microphone Unit ) 外形図

58
第5章 外形図

5.6 防水マイクユニット ( Waterproof Microphone Unit:NVT-162 )

オプション

防水マイクユニット( Waterproof Microphone Unit ) 外形図

59
第5章 外形図

5.7 接点信号入力器 64CH ( Digital Signal Converter:NCT-72 )

オプション

64CH ( Digital Signal Converter ) 外形図


接点信号入力器 16CH

60
第5章 外形図

5.8 接点信号入力器 16CH ( Digital Signal Converter:NCT-63 )

オプション

接点信号入力器 16CH ( Digital Signal Converter ) 外形図

61
第5章 外形図

5.9 レーダ I/F ユニット ( Radar Interface Unit:NWP-46 )

オプション

レーダ I/F ユニット ( Radar Interface Unit ) 外形図

62
63
記録制御機 ( Recording Control Unit ) 系統図
(2) (4) (4) (3) (3)
J305 J304 J303 J310 J309
Backup TEST Batt. line AC line FAN
SW SW SW
Sensor Control
BATT Thrm. UPS DC Power out
J306 J307 J308
(2) (8) (10)
(4) (2)
J405 J404
TB402 7JTJD0031 TB401 7JTJD0030
TB405 7JTJD0033 TB404 7JTJD0033
(2) (8) (10)
J403 J402 J401
TB403
TB406 7JTJD0036
7JTJD0035
J409 J408 (64) J407 (90) J406 (90)
(8)
J801 J701 J501
RECORDING
(8) RESTART
J1001 REC STOP
CF CARD
MEDIA
BACKUP STOP
J504
D-SUB15 D-SUB15
JRC-LAN VDR-LAN
RGB2 Input RGB1 Input J702 J703 J502 J503
CF
J804 J803 J602
(50)
(15) (15)
CF Card
W110 LAN cable 7ZCJD0284
W109 LAN cable 7ZCJD0284
(50)
J901
(4)
J1101
NDV-1800 記録制御機 ( Recording Control Unit ) 6.1
系統図 第6章
第6章 系統図

6.2 操作表示器 ( Operation Panel Unit ) NCG-169

J1101

操作表示器 ( Operation Panel Unit ) 系統図

64
6.3

TB1
MIC CN1 MIC+
+ RED 1 TTYCS-1Q
1 MIC-
- BLUE MIC AMP Board 2
2 SHIELD
+ YELLOW MIC-P2(R1) 3 RCU
3 SP+

65
- WHITE 4
4 SP-
5
SPEAKER
マイクユニット ( Microphone Unit ) NVT-161

マイクユニット ( Microphone Unit ) 系統図


TB1:WAGO 255 Series

Microphone Unit (NVT-161)Connection Diagram


第6章
系統図
第6章 系統図

6.4 防水マイクユニット ( Waterproof Microphone Unit ) NVT-162

オプション

防水マイクユニット ( Waterproof Microphone Unit ) 系統図

66
6.5
TB1 TB2 TB3 TB4
1 CH01 CH09 32 CH17 CH25 1 CH33 CH41 32 CH49 CH57
CH02 CH10 CH18 CH26 CH34 CH42 CH50 CH58

CH03 CH11 CH19 CH27 CH35 CH43 CH51 CH59

J1
CH04 CH12 CH20 CH28 CH36 CH44 CH52 CH60 Dry Contact in

P51
CH05 CH13 CH21 CH29 CH37 CH45 CH53 CH61
x64ch
W102
CH06 CH14 CH22 CH30 CH38 CH46 CH54 CH62
7ZCJD0286
AC/DC Power Supply Unit CH07 CH15 CH23 CH31 CH39 CH47 CH55 CH63
AES30-12 CH08 CH16 CH24 CH32
32 1 CH40 CH48 32 CH56 CH64 1
オプション

J202
Dry Contact Input Board
P1
CQD-2081

J2

W101
CN1
7ZCJD0189A
POWER IN
AC85~132V or
AC170~265V J102

U
FUSE
AC Filter Board RCU

V
TB101 NMEA data output

67
CBJ-147 1 Tx+
Dry Contact Control Board

E
Tx-
CDJ-2333 GND
Rx+
O I

SW
J104 5 Rx-

TB1
J103
接点信号入力器 64CH ( Digital Signal Converter )
NCT-72

接点信号入力器 64CH ( Digital Signal Converter ) 系統図


第6章

Digital Signal Convertor 64CH (NCT-72)


系統図

Connection Diagram
TB1 TB2 TB3 TB4
第6章

1 CH01 CH09 32 CH17 CH25 1 CH33 CH41 32 CH49 CH57


CH02 CH10 CH18 CH26 CH34 CH42 CH50 CH58

CH03 CH11 CH19 CH27 CH35 CH43 CH51 CH59

J1
CH04 CH12 CH20 CH28 CH36 CH44 CH52 CH60 Dry Contact in

P51
系統図

W102 CH05 CH13 CH21 CH29 CH37 CH45 CH53 CH61


x64ch
CH06 CH14 CH22 CH30 CH38 CH46 CH54 CH62
7ZCJD0286
AC/DC Power Supply Unit
CH07 CH15 CH23 CH31 CH39 CH47 CH55 CH63
AES30-12 CH08 CH16 CH24 CH32 1 CH40 CH48 32 CH56 CH64 1
32

J202
Dry Contact Input Board
P1
CQD-2081

J2

W105
W101
CN1 7ZCJD0238
POWER IN 7ZCJD0189A
AC85~132V or
AC170~265V
J102

U
FUSE
AC Filter Board RCU

V
TB101 NMEA data output

68
CBJ-147 1 Tx+
Dry Contact Control Board

E
Tx-
CDJ-2333 GND
Rx+
O I

SW
J104 5 Rx-

TB1
J103

W104
7ZCJD0263

J303

TB301 TB302 Analog data in


1 CH0+ 1 CH4+ x8ch
CH0- CH4-
CH1+ CH5+
A/D Convert Board CH1- CH5-
CH2+ CH6+
J301

CEF-60 CH2- CH6-


CH3+ CH7+

接点信号入力器 64CH ( Digital Signal Converter ) + A/D 変換ボード(オプション)付


8 CH3- 8 CH7-
J302

系統図
Digital Signal Convertor 64CH (NCT-72) + Option: A/D Board 8CH
Connection Diagram
6.6
TB1
1 CH01 CH09

CH02 CH10

CH03 CH11 Dry Contact in


CH04 CH12 x16ch

P51
J201
W102 CH05 CH13

7ZCJD0286 CH06 CH14


AC/DC Power Supply Unit CH07 CH15
AES15-12 CH08 CH16 32
オプション

Dry Contact Input Board

J202
P1 CQD-2012

J2

W101
CN1
POWER IN 7ZCJD0189A
AC85~132V or
AC170~265V
J102

U
FUSE RCU
AC Filter Board TB101 NMEA data output

69
1 Tx+
CBJ-147
Dry Contact Control Board Tx-

E
GND
CDJ-2333
O I Rx+
Rx-

SW
J104 5

TB1
J103
接点信号入力器 16CH ( Digital Signal Converter )

接点信号入力器 16CH ( Digital Signal Converter ) 系統図


NCT-63
第6章

Digital Signal Convertor 16CH (NCT-63)


系統図

Connection Diagram
TB1
第6章

1 CH01 CH09

CH02 CH10

CH03 CH11 Dry Contact in


CH04 CH12 x16ch

P51
J201
系統図

CH05 CH13
W102
7ZCJD0286 CH06 CH14
AC/DC Power Supply Unit CH07 CH15
AES-30-12 CH08 CH16 32

Dry Contact Input Board

J202
P1 CQD-2012

J2

W105 W101
CN1
7ZCJD0238 7ZCJD0189A
POWER IN
AC85~132V or
J102

U
AC170~265V FUSE
RCU
AC Filter Board TB101 NMEA data output

V
1

70
CBJ-147 Tx+
Dry Contact Control Board Tx-

E
CDJ-2333 GND
O I Rx+

SW
J104 5 Rx-

TB1
J103

W104
7ZCJD0263

J303

TB301 TB302 Analog data in


1 CH0+ 1 CH4+ x8ch
CH0- CH4-
CH1+ CH5+
A/D Convert Board CH1- CH5-
CH2+ CH6+
J301

CEF-60 CH2- CH6-


CH3+ CH7+
8 CH3- 8 CH7-

接点信号入力器 16CH ( Digital Signal Converter ) + A/D 変換ボード(オプション)付


J302

系統図
Digital Signal Convertor 16CH (NCT-63) + Option: A/D Board 8CH
Connection Diagram
第6章 系統図

6.7 レーダ I/F ユニット ( Radar Interface Unit ) NWP-46

オプション

レーダ I/F ユニット ( Radar Interface Unit ) 系統図

71
JCY-1800
航海データ記録装置
IMO MSC.214(81) 対応

取扱説明書

Not use the asbestos

JRCウェブサイト http://www.jrc.co.jp
マリンサービス部
〒141-0032 東京都品川区大崎1丁目18番7号
電話番号 (03)3492-1305
FAX番号 (03)3779-1420
e-mail tmsc@jrc.co.jp
アムステルダム支店
電話番号 +31-(0)20-658-0750
FAX番号 +31-(0)20-658-0755
e-mail service@jrcams.nl
シアトル支店
電話番号 +1-(0)206-654-5644
FAX番号 +1-(0)206-654-7030
e-mail service@jrcamerica.com
コード No.7ZPJD0386B 01JTM ISO9001, ISO14001 認証取得
2008 年 5 月作成 1版 JRC

You might also like