Professional Documents
Culture Documents
PARAMETERS
Pipeline Size OD (PSOD)
Wt of Steel Pipe/ft (WTST)
Fresh Water Density (FWD)
Sea Water Density (SWD)
Concrete SG (Specific Gravity)
Bouyancy Force
Weight of Concrete
Weight of Water displaced by Uncoated Pipe
Negative Bouyancy
Required Net Force for Pipeline Stability (NDFFPS)
Total Diameter (D)
Thickness of Cement Required
COMMENTS
SSING
24.00''
145.00 lb/ft
62.40 lb/ft3
65.52 lb/ft3
2.80
278.90lb/ft 205.86lb/ft
194.76 lbf/ft
205.86 lbf/ft
60.86 lbf/ft
60.86 lbf/ft
27.93''
1.97''
CALCULATION SHEET
CONCRETE THICKNESS FOR OPEN RI
PARAMETERS
Pipeline Size OD (PSOD)
Wt of Steel Pipe/ft (WTST)
Fresh Water Density (FWD)
Sea Water Density (SWD)
Concrete SG (Specific Gravity)
Bouyancy Force
Weight of Concrete
Weight of Water displaced by Uncoated Pipe
Negative Bouyancy
Required Net Force for Pipeline Stability (NDFFPS)
Total Diameter (D)
Thickness of Cement Required
COMMENTS
OSSING
0.6096m
215.78 kg/m
1000.00 kg/m3
1049.00 kg/m3
2.8000
538.68 kg/m
620.53 kg/m
306.20 lbf/ft
90.42 lbf/ft
297.63 kg/m
0.8085m
0.0995m
CALCULATION SHEET
CONCRETE THICKNESS FOR OPEN RIVE
PARAMETERS
Pipeline Size OD (PSOD)
Wt of Steel Pipe/ft (WTST)
Fresh Water Density (FWD)
Sea Water Density (SWD)
Concrete SG (Specific Gravity)
Bouyancy Force
Weight of Concrete
Weight of Water displaced by Uncoated Pipe
Negative Bouyancy
Required Net Force for Pipeline Stability (NDFFPS)
Total Diameter (D)
Thickness of Cement Required
COMMENTS
CROSSING
28.32 kg/m
1000.00 kg/m3
1029.00 kg/m3
3.15 From Std Table
17.95 kg/m 50.95330610637
10.56 lbf/ft
-17.76 lbf/ft
33.00 kg/m 0.03473609
0.1490m 5.9''
0.0174m 0.6838''
15.0466938936312
10.56 kg/m