* Section properties

Area = 338.1 mm2


Ixx = 55827.8 mm4 Element 1
Iyy = 90701.4 mm4
Zxx = 2201.4 mm3
Zyy = 4535.1 mm3
Rx = 12.8 mm Element 2
Ry = 16.4 mm

* Check for local buckling


About x-x axis,

e = (250 / 110)^0.5
= 1.51

For element 1, ( Outstand )


yo/yc = -11.6/25.4 = -0.46

g= 0.56 b=gxb/t
b= 37.0 mm = 0.56 x 37.0 / 3.0
t= 3.00 mm = 6.93

bo = 7 x 1.51 = 10.6 > 6.93

b1 = 6 x 1.51 = 9.05 > 6.93

Ie. Element 1 is fully compact section.


Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 23

For element 2, ( Internal )


yo/yc = 11.6/11.6 = 1

g= 1.00 b=gxb/t
b= 34.0 mm = 1.0 x 34.0 / 3.0
t= 3.00 mm = 11.3

bo = 22 x 1.51 = 33.2 > 11.3

b1 = 18 x 1.51 = 27.1 > 11.3

Ie. Element 2 is fully compact section.

Ie. the section is fully compact about x-x axis.

* Check for bending

(Refer to Appendix A, WIND, Frame no. 2)

Factored max. bending moment, M = 1.4 x 50778.23


= 71089.5 Nmm

Bending moment capacity, Mc = 1.2 x po x Zxx / 1.2


= 1.2 x 110 x 2201.4 / 1.2
= 242157.2 Nmm > M = 71089.5 Nmm OK
Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 24

* Check for shear

(Refer to Appendix A, WIND, Frame no. 2)

Factored shear force, Fv = 1.4 x 565.56


= 791.8 N

Shear capacity, Fvc = pv x Area / 1.2


= 65 x 338.1 / 1.2
= 18315.8 N > Fv = 791.8 N OK
Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 25

* Check for deflection

(Refer to Appendix A, WIND, Joint no. 3)

Max. total deflection, dt = (0.00444^2 + 0.34465^2)^0.5


= 0.34 mm

Limiting deflection, = L / 180


= 575.0 / 180
= 3.19 mm > dt = 0.34 mm OK

* Lateral torsional buckling

Ie. Bending about minor axis, lateral torsional buckling can be ignored.
Project: PROPOSED DEVELOPMENT AT
SKYCITY SITE A2 L894,
PORTION OF CHEK LAP KOK
LOT NO. 3
Wah Tung Facade Company Limited Prepared: Date: 31-Aug-20
Checked: File: Page: 26

* Check for M6 stud bolt (@200c/c)

Non-factored tensile force per bolt, Ft1a = 2.59 kPa x 2 x 0.32 m x 0.2 m x 1000
= 331.5 N

Stress area, A= 20.1 mm2

Proof stress, pf = 95.0 MPa

Tension capacity, Ftc = At x pf / 3 (FOS = 3)


= 20.1 x 95.0 / 3
= 636.5 N > Ft1a = 331.5 N OK