You are on page 1of 6

CP CU1

Technical Data
CP CU1 Technical Data

© OMICRON electronics GmbH 2015. All rights reserved.


This technical data was extracted from the following manual: ENU 1030 04 01
All rights including translation reserved. Reproduction of any kind, for example, photocopying,
microfilming, optical character recognition and/or storage in electronic data processing systems,
requires the explicit consent of OMICRON.
The document content represents the technical status at the time of writing and is subject to change
without prior notice.
We have done our best to ensure that the information given in this document is useful, accurate and
entirely reliable. However, OMICRON does not assume responsibility for any inaccuracies which may
be present.
OMICRON translates this document from the source language English into a number of other
languages. Any translation of this document is done for local requirements, and in the event of a dispute
between the English and a non-English version, the English version of this document shall govern.

2
Technical data

1 Technical data
1.1 CP CU1 output ranges
Table 1-1 Output ranges of the CP CU1
Range Current Compliance Voltage at > 45 Hz
10 A 0…10 Arms 500 Vrms
20 A 0…20 Arms 250 Vrms
50 A 0…50 Arms 100 Vrms
100 A 0…100 Arms 50 Vrms

1.2 CP CU1 measuring transformers


Table 1-2 Measuring transformers of the CP CU1
Transformer Ratio Accuracy at 50/60 Hz
VT 600 V : 30 V Class 0.1
CT 100 A : 2.5 A Class 0.1

1.3 CP CU1 inputs


Table 1-3 Inputs of the CP CU1
Characteristic Rating
Overvoltage category CAT III (IEC 61010-1)
V SENSE Voltage range 0…600 Vrms
Overvoltage category CAT I
Voltage range 0…200 Vrms
Current range 0…30 Arms
BOOSTER1
Frequency range 15…400 Hz
Fuse 30 A fast acting,
automatic circuit breaker
1. The BOOSTER input supplies power to the CP CU1. It must be connected only to the CPC 100.

3
CP CU1 Technical Data

1.4 CP GB1 specifications


Table 1-4 CP GB1 specifications
Characteristic Rating
Nominal AC spark-over voltage < 1000 Vrms
Impulse spark-over voltage < 2000 Vpeak
Short-circuit proof with:
16 mm cylindrical or 20 mm ball studs 26.5 kA (<100 ms)/67 kApeak
25 mm or 1 inch ball studs 30 kA (<100 ms)/75 kApeak
Torsional moment for changing arrestors > 15 Nm

1.5 Output power


Table 1-5 Output power of the CPC 100 and CP CU1
Characteristic Rating1
5000 VA (45…70 Hz), cos < 1.0 for 8 s at 230 V AC
mains voltage
Maximum power
5000 VA (45…70 Hz), cos < 0.4 for 8 s at 115 V AC
mains voltage
Continuous power 0…1600 VA
Frequency 15…400 Hz (15…45 Hz with reduced voltage)
1. Ambient temperature 23 ºC ± 5 ºC/73 ºF ± 10 ºF

1.6 Accuracy
Table 1-6 Accuracy of the CPC 100 and CP CU1
Impedance Typ. Typ. V SENSE I OUT Current
Range Accuracy1 Accuracy1 Voltage Current Range
of abs(Z) of Phase
Value Angle
0.05…0.2  1.0…0.5% 1.5…0.8º 5…20 V 100 A 100 A
0.2…2  0.5…0.3% 0.8…0.5º 20…50 V 100…25 A 100 A
2…5  0.3% 0.5º 100 V 50…20 A 50 A
5…25  0.3% 0.5º 100…250 V 20…10 A 20 A
25…300  0.3…1.0% 0.5…1.5º 250…500 V 10…1.5 A 10 A
1. Ambient temperature 23 ºC ± 5 ºC/73 ºF ± 10 ºF

4
Technical data

1.7 Environmental conditions


Table 1-7 Environmental conditions for the CP CU1 and CP GB1
Characteristic Rating
Operating temperature –10…+55 ºC/14…131 ºF
Transport & storage temperature –20…+70 ºC/–4…158 ºF
Relative humidity 5…95%, non-condensing
Safety EN 61010-1
Prepared for IEEE 510, EN 50191 (VDE 0104),
EN 50110-1 (VDE 0105 Part 100),
LAPG 1710.6 NASA "Electrical Safety"
Protection IP20

1.8 Mechanical data


Table 1-8 Mechanical data of the CP CU1 and CP GB1
Characteristic Rating
450 × 220 × 220 mm/
Dimensions (w × h × d)
CP CU1 17.72 × 8.66 × 8.66 inch
Weight 28.5 kg/62.78 lb
Dimensions ( × h) 200 × 190 mm/7.87 × 7.48 inch
4.2 kg/8.81 lb (without grounding
CP GB1 cable)
Weight
approx. 6.8 kg/13.22 lb
(with grounding cable)

This product complies with all applicable EU directives.

5
CP CU1 Technical Data

You might also like