You are on page 1of 1

FDD40S Prime Power : 32 kW / 40 kVA

Standby Power : 35 kW / 44 kVA


Specifications, pictures, and dimensions may change due to product improvements

Genset Controller :
Engine Specifications :
Engine Type : FEDERAL FE4100ZD
Speed (rpm) : 1500
Frequency (Hz) : 50
No. of cylinders : 4 (in-line)
Displacement : 3.61
Bore / Stroke (mm) : 100 / 115
Compression Ratio : 17 : 1
Fuel Consumption (l/h) : 6.9 at 100% Load (PRP) SmartGen HGM420
Auto Mains Failure (AMF) Control Modules
Alternator Specifications : - 132x64 LCD with backlight, selectable language interface, push-button operation
Brand / Model : FEDERAL F184J - Improved LCD wear-resistance and scratch resistance due to hard screen acrylic
Type : 3 Phases - Single Bearing - Silicon panel and pushbuttons for better operation in high/low temperature
environment
Rated Output (kVA) : 40 - Suitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase
Speed (rpm) : 1500 3-wire systems with voltage 120/240V and frequency 50/60Hz
Frequency (Hz) : 50 - Collects and shows 3-phase voltage, current, power parameter and frequency of
Voltage (V) : 400 / 230 generator or mains
Insulation / Protection : Class H / IP-23 - For Mains, controller has over voltage, under voltage and loss of phase detection
functions; For generator, controller has over voltage, under voltage, over frequency,
Cooling System & Accessories : under frequency, over current and over power detection functions
- Precision collect and display parameters about Engine
Cooling System Radiator : - Control & Protection: automatic start/stop of the genset, ATS (Auto Transfer
Batteries
12 V : Switch) control with perfect fault indication and protection function
Exthaust System :
Industrial / Residential exthaust silencer
- etc.
Base Frame :
Steel Channel / Plate construction
(Incld. daily tank for 8 hours operations)
Mounting : Rubber metal elements
Features & Benefits
- High power and maximum efficiency
Set of Operation Books : - Engine operation instructions
- Low operating costs as a result of low levels of lubricant and fuel consumption as
consist of - Certificate of Origin (COO)
well as extended service intervals
- Alternator operation instructions
- Generator set test report - Low emissions due to state-of-the-art combustion technologies
- Low space requirement due to compact design
Dimensions : - Reliable in use thanks to field-tested technology
- Long service life resulting from application-specific design

PT. Tan Energy Indonesia (TANEKO)


Alamanda Tower Lt. 28-D, Jl. TB Simatupang Kav. 23-24
Open Type Silent Type Cilandak Barat, Jakarta 12430 - INDONESIA
N/A L x W x H : 2150 x 900 x 1115 (mm)
Ph.: (+62-21) 7590 5072 / 7590 5073
N/A Dry Weight : 1350 (kg)
Email: marketing@taneko.co.id | Website: www.taneko.co.id
Prime Power (PRP)
According to ISO8528-1, prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals. The permissible average power output
during at 24 hours period shall not exceed 80% of the prime power. 10% overload available for governing purposes only.
Standby Power (ESP)
According to ISO 8528-1, It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 hours of operation per year (of which no more than 300 hours for
continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.

FEDERAL Generator Products are compliant with ISO 9001 and CE standard, which include the following directives:
• 2006/42/EC Machinery safety
• 2006/95/EC Low voltage
• EN 60204-1: 2006+A1: 2009, EN ISO 12100: 2010, EN ISO 13849-1: 2008, EN 12601 : 2010

You might also like