You are on page 1of 2

CSI Code: 32 13 73.

16

NO. 224 NOVEMBER 2008


(Supersedes March 2003)
SOF-SEAL®
Cold-Applied, Low-Modulus Horizontal Joint Sealant

DESCRIPTION FEATURES/BENEFITS
Cold-applied SOF-SEAL low modulus horizontal • Provides a cost-effective alternative to hot-
joint sealant is a premium-grade, pourable, two- applied sealants.
component sealant composed of a special • Delivers reliable, consistent performance, even
combination of polymeric compounds that provides during cold weather or after repeated
outstanding performance in both Portland cement freeze-thaw cycles.
and asphalt concrete. Once properly mixed and • Remains pliable in the joint for years ... a superb
applied, it cures within two hours to a soft, highly preventive maintenance factor.
flexible, rubber-like material that is capable of • Accommodates joint movement effectively over
maintaining a sealed joint or crack over a wide a wide range of temperatures.
temperature range. SOF-SEAL does not track in the • Offers exceptional elongation and longevity, high
summer and will not become brittle at temperatures resiliency, and tenacious bonding power.
as low as -20° F (-29° C). It remains soft, flexible, • Rejects ingress of incompressibles.
and pliable in the joint, even after repeated • Does not become brittle or crack out in winter ...
freeze/thaw cycles. SOF-SEAL offers excellent will not flow in warm weather.
elongation, high resiliency, tenacious bonding • Maintains low stress development because of its
power, and excellent longevity. low modulus properties.
• A proven alternative to silicone-based sealants.
This self-leveling sealant requires no special • Can be used as a pitch pan sealant.
application equipment and can easily be poured
into cracks and joints. TECHNICAL DATA
USES Application Life (Pot Life) @ 70°F (21°C) 45 Minutes
SOF-SEAL is a versatile pavement sealant suitable Initial Cure: approx. 2 hours
for either large- or small-scale sealing. It is excellent
for crack repair and preventive maintenance sealing Penetration mm/10
projects. It is ideal for use when a maintenance @ 77° F (25° C) 140
group doesn’t have a melter, or where it is not @ 0° F (-18° C) 35
practical to fire up and repeatedly move melter- Flow, cm None
applicator units (small-scale sealing projects). 90%
Resilience, %
Typical applications include the sealing of expansion
and contraction joints, longitudinal joints and Bond Test, 3 cycles
random cracks in concrete pavements, reflective and 200% extension @ -20° F (-29°C) Pass 3 cycles
random cracks in asphalt paving, and asphalt-to- Elongation, 300% @ -20° F (-29° C) Pass 1 cycle
concrete shoulder joints. It is also ideal for high-
sheer bridge joint applications. In addition, SOF- COVERAGE
SEAL can be used as a pitch pan sealant. 7.47 gal./ft.3 (1000 L/m3). A joint 1/2” x 1/2” (12.7
PACKAGING mm x 12.7 mm) will require 1.3 gal./100 linear feet
Two-component SOF-SEAL is packaged in (16 liters/100 m).
convenient three-gallon (11.36 liter) units. The base SHELF LIFE
material is furnished in an oversized container When stored indoors in original, unopened
suitable for mixing and pouring. The activator is containers at temperatures between 40° - 90° F (4° -
furnished in a bottle inserted in a plastic bag, which 32° C), optimum performance and best use is
hangs inside the container. Both components are pre- obtained within two years of date of manufacture.
measured to exact quantities. Mix all materials in
container; do not mix partial units.

CONTINUED ON REVERSE SIDE…


PAGE 2 … SOF-SEAL #224 … NOVEMBER 2008

LEED INFORMATION A. Preferred Method ... Mixing with a variable speed


May help contribute to LEED credits: drill fitted with a slotted, flat-headed paddle is best
 EQ Credit 4.1: Low Emitting Materials: accomplished when the drill is operated at slow
Adhesives and Sealants speeds, not to exceed 400 rpm. MIXING TIME IS
 MR Credit 5.1: Regional Materials: 10% FIVE MINUTES MINIMUM.
Extracted, Processed & Manufactured
Regionally B. Mixing by hand can be accomplished with a flat,
 MR Credit 5.2: Regional Materials: 20% wooden mixing paddle. MIXING TIME BY HAND
Extracted, Processed & Manufactured IS EIGHT MINUTES MINIMUM.
Regionally Pouring ... SOF-SEAL may be poured from its
original container or any clean container suitable for
APPLICATION pouring. A commercial sealing pot equipped with a
Surface/Joint Preparation … Remove foreign narrow pouring spout and shutoff valve is ideal. Fill
substances, incompressibles, and free water from cracks or joints flush with pavement surface. If cracks
joint opening. For proper adhesion, joints must be are overfilled, use a squeegee to achieve a uniform
clean and surface dry. Dust, dirt, and laitance appearance. To facilitate prompt opening to vehicular
should be removed prior to application. SOF- traffic, about one hour after applying sealer, dust with
SEAL adheres well to unprimed concrete. Proper limestone dust or talc, as an example, to minimize
joint design practices and applications must be tracking.
followed for successful performance. SOF-SEAL
should be used on joints not less than 1/4” (6.35 Cleanup ... Before material has cured, use an
mm) wide. A 2:1 width-to-depth ratio should be aromatic solvent, such as toluene. After material has
maintained. For straight joint edges, mask off top cured, it will be necessary to cut or abrade the
surfaces with masking tape. To control sealant material from equipment.
depth, insert KOOL-ROD™ backer rod or PRECAUTIONS
DECK-O-FOAM® from W. R. MEADOWS in SOF-SEAL components are pre-measured to exact
the joint before sealing. For larger joints, where quantities. Mix all materials in container; do not mix
additional support is required, use a non-asphalt partial units or dilute. Apply only when the
joint filler, such as CERAMAR® flexible foam temperatures of the air and joint interfaces are 40° F
expansion joint filler from W. R. MEADOWS. (4° C) or higher. Avoid contact with skin or
prolonged breathing of vapors. Refer to Material
Mixing ... Prior to mixing, SOF-SEAL should be
Safety Data Sheet for complete health and safety
stored at temperatures of 55° F (13° C) or higher.
information.
The two components of SOF-SEAL are pre-
measured and must be mixed together at one time. For most current data sheet, further LEED
Add the activator to the base material and blend information, and MSDS, visit
thoroughly. Mixing can be accomplished with a www.wrmeadows.com.
variable speed drill operated at slow speeds (see
A) or by hand (see B). In either case, the mixing
should be interrupted occasionally and the mixing
paddle used to wipe material from the sides and
bottom of the container for thorough blending.

© W. R. MEADOWS 2001 11/08-4M