FUNDAMENTALS OF V3F18

~~=m
ly
Fine adjustment of the. LWD (with the weights of half and 90
% of the car nominal load)
1. Perfonn the "Basic LWD setting" see previous page .
. 2. Over 90 % load:
-Put about 90 % ofthe nominal load in the car.
-Write the number ofkilos ofthe load to the submenu 61
74.
-Save the value iri submenu 6/99, choice 1.
If the second value (the weight used in "Basic LWD setting) was more
than 90 % ofthe nominal load, you cannot enter a third weight value to
the user interface.
Depending on the mechanics, the operation of the LWD is not always
linear. It may be difficult to get correct load values when driving the
") elevator with full load. In that case it is advisable to give the system all
the three reference points, as described above.

VoltageN Slope defmed with two reference points (1,2)


Slope defined with three reference points (1, 2, 3)

(1) Zero point (0% load)


(2) Second reference point (40-60 % load)
(3) Third reference point (90 % load)

Load/kg
0% 40-60% 90%
P1DOOO12D.wrnf

.....