You are on page 1of 3

Loads P.Unit H P. TOT POW + MARG.

Bulbs/Lamps 0 10 0 0
Microwave 500 4 2000 2,400
Appliance 2 0 0 0 0
Appliance 3 0 3 0 0
Appliance 4 0 2 0 0

Total 500 19 2000 2,400

Gadgets CC 0 25 0 0

P.TOT 2,807

Radiation Data base


http://re.jrc.ec.europa.eu/pvgis/apps4/pvest.php

Visit My Blog for others Spreadsheet, Calculators and app


My Blog

This spreadsheet is only an estimate. If you want to calculate an off-grid installation, contact a contractor or engin
Data and Specifications

Power in Wh/Day 2,807.02 Needed panels


Voltage Battery 24.00 Serial panel group
Autonomy (Days) 2 Parallel panel group
Battery
P. Panel (in W) 380.00 Battery Capacity
PSH - Kwh/m2 (According to Radiati 5.00 Inverter Power (Oversized)
Producton Estimate
Panel Voltage Max. 36.00 Panels
Imax. Panel 4.90 Serial
Max. Seasonal Discharge Depth 0.70 Parallel
Maximum Day Discharge Depth 0.15
I. Max. Panel In Shortcircuit 5.30 Ah
Power in CC - Courrent Pnel
Power in AC 500.00 Parallel panel group
Global Work Factor 0.90 Nominal Capacity Battery Day
Nominal Capacity Battery Seasonal
Input Regulatory Calculation
Output Regulatory Calculation
Inverter Power (Oversized)

alculate an off-grid installation, contact a contractor or engineer to evaluate your case.


2
1
2
8,020.05 W
334.17 A/h
2,400.00 W
760.00 Wh
1.64 2
0.67 1
2.00 2

116.96
23.39
4.77 5
18,713.45 W/h 779.73 Ah
8,020.05 W/h 334.17 Ah
33.13 A
27.41 A
2,400.00 W

You might also like