You are on page 1of 8

SWEDISH LOAD SOUNDING TEST

Location SW Test for Relay House and Sub Signal House in Yangon-Mandalay Railway Project (Darbain Station) Date 15.05.2020
Point No. SWT-01 Elevation 5.044 m Operator SMK, TPO & MTKK

N value
Bearing BORING LOG (ESTIMATE SOIL LAYER) Weather Sunny Water Level GL- 1.6 m
from

SPT N value

from swedish
Capacity Depth Wsw (kg) Nsw
W sw Na N sw

Soil Name

sounding
Depth (m)
Depth L sewdish

Thickness

N value
m

GL- (m)
Description

(m)

Depth
sounding

Scale

Scale
(kg) (m) (cm) qa (kN/m2) 0 5 15 25 50 75 0 50 100 200 300 400 500 600

0.00
5.0 0.010 1.0 0.2 0.0
15.0 0.030 2.0 0.5 0.0 0.50 0.50 0.50
25.0 0.050 2.0 0.8 0.0
50.0 0.070 2.0 1.5 0.1 1.00 1.00 1.00

75.0 0.100 3.0 2.3 0.2


1.50 1.50 1.50
100.0 0.130 3.0 3.0 0.3
100.0 12.0 0.250 12.0 100.0 8.0 90.0 2.00 2.00 2.00
100.0 12.0 0.500 25.0 48.0 5.4 58.8
100.0 4.0 0.750 25.0 16.0 3.8 39.6 2.50 2.50 2.50

100.0 2.0 1.000 25.0 8.0 3.4 34.8


3.00 3.00 3.00
100.0 3.0 1.250 25.0 12.0 3.6 37.2
100.0 3.0 1.500 25.0 12.0 3.6 37.2 3.50 3.50 3.50
100.0 4.0 1.750 25.0 16.0 3.8 39.6
100.0 4.0 2.000 25.0 16.0 3.8 39.6 4.00 4.00 4.00

100.0 3.0 2.250 25.0 12.0 3.6 37.2


4.50 4.50 4.50
100.0 3.0 2.500 25.0 12.0 3.6 37.2

Clayey Soil
100.0 1.0 2.750 25.0 4.0 3.2 32.4 5.00 Clayey Soil 5.00 5.00
100.0 4.0 3.000 25.0 16.0 3.8 39.6
100.0 4.0 3.250 25.0 16.0 3.8 39.6 5.50 5.50 5.50

100.0 3.500 25.0 0.0 3.0 0.3


100.0 3.750 25.0 0.0 3.0 0.3 6.00 6.00 6.00

100.0 4.000 25.0 0.0 3.0 0.3


6.50 6.50 6.50
100.0 4.250 25.0 0.0 3.0 0.3
100.0 1.0 4.500 25.0 4.0 3.2 32.4 7.00 7.00 7.00
100.0 1.0 4.750 25.0 4.0 3.2 32.4
100.0 4.0 5.000 25.0 16.0 3.8 39.6 7.50 7.50 7.50

100.0 5.0 5.250 25.0 20.0 4.0 42.0


8.00 8.00 8.00
100.0 5.0 5.500 25.0 20.0 4.0 42.0
100.0 7.0 5.750 25.0 28.0 4.4 46.8 8.50 8.50 8.50
100.0 7.0 6.000 25.0 28.0 4.4 46.8
100.0 8.0 6.250 25.0 32.0 4.6 49.2 9.00 9.00 9.00

100.0 9.0 6.500 25.0 36.0 4.8 51.6


9.50 9.50 9.50
100.0 9.0 6.750 25.0 36.0 4.8 51.6
100.0 10.0 7.000 25.0 40.0 5.0 54.0 10.00 10.0 10.0 10.00
10.00
Remark: N sw =(100/L)*N a N-value of SPT is calculated from Swedish Load Sounding test qu=0.0045*Wsw+0.0075*Nsw
N sw :Nos. of half rotation per meter N=0.02W sw (kgf)+0.067N sw (For Sandy Soil) qu=Unconfined compressive strength (kgf/cm2)
N a :Nos.of half rotation for each length N=0.03W sw (kgf)+0.050N sw (For Clayey Soil) DS-Disturbed Sample
W sw :Weight(kg)

Fukken Co., Ltd. (Yangon Branch), www.fukkenmyanmar.com


SWEDISH LOAD SOUNDING TEST
Location SW Test for Relay House and Sub Signal House in Yangon-Mandalay Railway Project (Darbain Station) Date 15.05.2020
Point No. SWT-01 Elevation 5.044 m Operator SMK, TPO & MTKK

N value
Bearing BORING LOG (ESTIMATE SOIL LAYER) Weather Sunny Water Level GL- 1.6 m
from

SPT N value

from swedish
Capacity Depth Wsw (kg) Nsw
W sw Na N sw

Soil Name

sounding
Depth (m)
Depth L sewdish

Thickness

N value
m

GL- (m)
Description

(m)

Depth
sounding

Scale

Scale
(kg) (m) (cm) qa (kN/m2) 0 5 15 25 50 75 0 50 100 200 300 400 500 600

0.00
100.0 10.0 7.250 25.0 40.0 5.0 54.0
100.0 10.0 7.500 25.0 40.0 5.0 54.0 0.50 0.50 0.50
100.0 12.0 7.750 25.0 48.0 5.4 58.8
100.0 12.0 8.000 25.0 48.0 5.4 58.8 1.00 1.00 1.00

100.0 13.0 8.250 25.0 52.0 5.6 61.2


1.50 1.50 1.50
100.0 14.0 8.500 25.0 56.0 5.8 63.6
100.0 16.0 8.750 25.0 64.0 6.2 68.4 2.00 2.00 2.00
100.0 16.0 9.000 25.0 64.0 6.2 68.4
100.0 17.0 9.250 25.0 68.0 6.4 70.8 2.50 2.50 2.50

100.0 19.0 9.500 25.0 76.0 6.8 75.6


3.00 3.00 3.00
100.0 19.0 9.750 25.0 76.0 6.8 75.6
100.0 17.0 10.000 25.0 68.0 6.4 70.8 3.50 3.50 3.50

4.00 4.00 4.00

4.50 4.50 4.50

Clayey Soil
5.00 Clayey Soil 5.00 5.00

5.50 5.50 5.50

6.00 6.00 6.00

6.50 6.50 6.50

7.00 7.00 7.00

7.50 7.50 7.50

8.00 8.00 8.00

8.50 8.50 8.50

9.00 9.00 9.00

9.50 9.50 9.50

10.00 10.0 10.0 10.00


10.00
Remark: N sw =(100/L)*N a N-value of SPT is calculated from Swedish Load Sounding test qu=0.0045*Wsw+0.0075*Nsw
N sw :Nos. of half rotation per meter N=0.02W sw (kgf)+0.067N sw (For Sandy Soil) qu=Unconfined compressive strength (kgf/cm2)
N a :Nos.of half rotation for each length N=0.03W sw (kgf)+0.050N sw (For Clayey Soil) DS-Disturbed Sample
W sw :Weight(kg)

Fukken Co., Ltd. (Yangon Branch), www.fukkenmyanmar.com


SWEDISH LOAD SOUNDING TEST
Location SW Test for Relay House and Sub Signal House in Yangon-Mandalay Railway Project (Darbain Station) Date 15.05.2020
Point No. SWT-02 Elevation 5.181 m Operator YMN-I & MMH

N value
Bearing BORING LOG (ESTIMATE SOIL LAYER) Weather Sunny Water Level GL- 1.5 m
from

SPT N value

from swedish
Capacity Depth Wsw (kg) Nsw
W sw Na N sw

Soil Name

sounding
Depth (m)
Depth L sewdish

Thickness

N value
m

GL- (m)
Description

(m)

Depth
sounding

Scale

Scale
(kg) (m) (cm) qa (kN/m2) 0 5 15 25 50 75 0 50 100 200 300 400 500 600

0.00
5.0 0.030 3.0 0.2 0.0
15.0 0.050 2.0 0.5 0.0 0.50 0.50 0.50
25.0 0.070 2.0 0.8 0.0
50.0 0.100 3.0 1.5 0.1 1.00 1.00 1.00

75.0 0.130 3.0 2.3 0.2


1.50 1.50 1.50
100.0 0.150 2.0 3.0 0.3
100.0 10.0 0.400 25.0 40.0 5.0 54.0 2.00 2.00 2.00
100.0 7.0 0.650 25.0 28.0 4.4 46.8
100.0 4.0 0.900 25.0 16.0 3.8 39.6 2.50 2.50 2.50

100.0 3.0 1.150 25.0 12.0 3.6 37.2


3.00 3.00 3.00
100.0 1.400 25.0 0.0 3.0 0.3
100.0 1.650 25.0 0.0 3.0 0.3 3.50 3.50 3.50
100.0 1.900 25.0 0.0 3.0 0.3
100.0 2.150 25.0 0.0 3.0 0.3 4.00 4.00 4.00

100.0 2.0 2.400 25.0 8.0 3.4 34.8

Clayey Soil
4.50 4.50 4.50
100.0 2.0 2.650 25.0 8.0 3.4 34.8 Clayey Soil
100.0 4.0 2.900 25.0 16.0 3.8 39.6 5.00 5.00
5.00
100.0 3.0 3.150 25.0 12.0 3.6 37.2
100.0 4.0 3.400 25.0 16.0 3.8 39.6 5.50 5.50 5.50

100.0 3.0 3.650 25.0 12.0 3.6 37.2


100.0 3.0 3.900 25.0 12.0 3.6 37.2 6.00 6.00 6.00

100.0 4.0 4.150 25.0 16.0 3.8 39.6


6.50 6.50 6.50
100.0 4.0 4.400 25.0 16.0 3.8 39.6
100.0 3.0 4.650 25.0 12.0 3.6 37.2 7.00 7.00 7.00
100.0 4.900 25.0 0.0 3.0 0.3
100.0 5.150 25.0 0.0 3.0 0.3 7.50 7.50 7.50

100.0 5.400 25.0 0.0 3.0 0.3


8.00 8.00 8.00
100.0 4.0 5.650 25.0 16.0 3.8 39.6
100.0 6.0 5.900 25.0 24.0 4.2 44.4 8.50 8.50 8.50
100.0 7.0 6.150 25.0 28.0 4.4 46.8
100.0 8.0 6.400 25.0 32.0 4.6 49.2 9.00 9.00 9.00

100.0 9.0 6.650 25.0 36.0 4.8 51.6


9.50 9.50 9.50
100.0 8.0 6.900 25.0 32.0 4.6 49.2
100.0 7.0 7.150 25.0 28.0 4.4 46.8 10.00
10.15 10.15 10.00
10.00
Remark: N sw =(100/L)*N a N-value of SPT is calculated from Swedish Load Sounding test qu=0.0045*Wsw+0.0075*Nsw
N sw :Nos. of half rotation per meter N=0.02W sw (kgf)+0.067N sw (For Sandy Soil) qu=Unconfined compressive strength (kgf/cm2)
N a :Nos.of half rotation for each length N=0.03W sw (kgf)+0.050N sw (For Clayey Soil) DS-Disturbed Sample
W sw :Weight(kg)

Fukken Co., Ltd. (Yangon Branch), www.fukkenmyanmar.com


SWEDISH LOAD SOUNDING TEST
Location SW Test for Relay House and Sub Signal House in Yangon-Mandalay Railway Project (Darbain Station) Date 15.05.2020
Point No. SWT-02 Elevation 5.181 m Operator YMN-I & MMH

N value
Bearing BORING LOG (ESTIMATE SOIL LAYER) Weather Sunny Water Level GL- 1.5 m
from

SPT N value

from swedish
Capacity Depth Wsw (kg) Nsw
W sw Na N sw

Soil Name

sounding
Depth (m)
Depth L sewdish

Thickness

N value
m

GL- (m)
Description

(m)

Depth
sounding

Scale

Scale
(kg) (m) (cm) qa (kN/m2) 0 5 15 25 50 75 0 50 100 200 300 400 500 600

0.00
100.0 10.0 7.400 25.0 40.0 5.0 54.0
100.0 10.0 7.650 25.0 40.0 5.0 54.0 0.50 0.50 0.50
100.0 11.0 7.900 25.0 44.0 5.2 56.4
100.0 11.0 8.150 25.0 44.0 5.2 56.4 1.00 1.00 1.00

100.0 13.0 8.400 25.0 52.0 5.6 61.2


1.50 1.50 1.50
100.0 11.0 8.650 25.0 44.0 5.2 56.4
100.0 11.0 8.900 25.0 44.0 5.2 56.4 2.00 2.00 2.00
100.0 11.0 9.150 25.0 44.0 5.2 56.4
100.0 14.0 9.400 25.0 56.0 5.8 63.6 2.50 2.50 2.50

100.0 14.0 9.650 25.0 56.0 5.8 63.6


3.00 3.00 3.00
100.0 14.0 9.900 25.0 56.0 5.8 63.6
100.0 14.0 10.150 25.0 56.0 5.8 63.6 3.50 3.50 3.50

4.00 4.00 4.00

Clayey Soil
4.50 4.50 4.50
Clayey Soil
5.00 5.00 5.00

5.50 5.50 5.50

6.00 6.00 6.00

6.50 6.50 6.50

7.00 7.00 7.00

7.50 7.50 7.50

8.00 8.00 8.00

8.50 8.50 8.50

9.00 9.00 9.00

9.50 9.50 9.50

10.00 10.15 10.15 10.00


10.00
Remark: N sw =(100/L)*N a N-value of SPT is calculated from Swedish Load Sounding test qu=0.0045*Wsw+0.0075*Nsw
N sw :Nos. of half rotation per meter N=0.02W sw (kgf)+0.067N sw (For Sandy Soil) qu=Unconfined compressive strength (kgf/cm2)
N a :Nos.of half rotation for each length N=0.03W sw (kgf)+0.050N sw (For Clayey Soil) DS-Disturbed Sample
W sw :Weight(kg)

Fukken Co., Ltd. (Yangon Branch), www.fukkenmyanmar.com


SWEDISH LOAD SOUNDING TEST
Location SW Test for Relay House and Sub Signal House in Yangon-Mandalay Railway Project (Darbain Station) Date 15.05.2020
Point No. SWT-03 Elevation 5.128 m Operator YMN-I & MMH

N value
Bearing BORING LOG (ESTIMATE SOIL LAYER) Weather Sunny Water Level GL- 1.3 m
from

SPT N value

from swedish
Capacity Depth Wsw (kg) Nsw
W sw Na N sw

Soil Name

sounding
Depth (m)
Depth L sewdish

Thickness

N value
m

GL- (m)
Description

(m)

Depth
sounding

Scale

Scale
(kg) (m) (cm) qa (kN/m2) 0 5 15 25 50 75 0 50 100 200 300 400 500 600

0.00
5.0 0.060 6.0 0.2 0.0
15.0 0.070 1.0 0.5 0.0 0.50 0.50 0.50
25.0 0.080 1.0 0.8 0.0
50.0 0.100 2.0 1.5 0.1 1.00 1.00 1.00

75.0 0.110 1.0 2.3 0.2


1.50 1.50 1.50
100.0 0.130 2.0 3.0 0.3
100.0 13.0 0.380 25.0 52.0 5.6 61.2 2.00 2.00 2.00
100.0 7.0 0.630 25.0 28.0 4.4 46.8
100.0 3.0 0.880 25.0 12.0 3.6 37.2 2.50 2.50 2.50

100.0 1.130 25.0 0.0 3.0 0.3


3.00 3.00 3.00
100.0 3.0 1.380 25.0 12.0 3.6 37.2
100.0 3.0 1.630 25.0 12.0 3.6 37.2 3.50 3.50 3.50
100.0 3.0 1.880 25.0 12.0 3.6 37.2
100.0 3.0 2.130 25.0 12.0 3.6 37.2 4.00 4.00 4.00

100.0 1.0 2.380 25.0 4.0 3.2 32.4


4.50 4.50 4.50
100.0 2.0 2.630 25.0 8.0 3.4 34.8

Clayey Soil
100.0 3.0 2.880 25.0 12.0 3.6 37.2 5.00 Clayey Soil 5.00 5.00
100.0 3.0 3.130 25.0 12.0 3.6 37.2
100.0 3.0 3.380 25.0 12.0 3.6 37.2 5.50 5.50 5.50

100.0 3.0 3.630 25.0 12.0 3.6 37.2


100.0 3.0 3.880 25.0 12.0 3.6 37.2 6.00 6.00 6.00

100.0 3.0 4.130 25.0 12.0 3.6 37.2


6.50 6.50 6.50
100.0 5.0 4.380 25.0 20.0 4.0 42.0
100.0 5.0 4.630 25.0 20.0 4.0 42.0 7.00 7.00 7.00
100.0 5.0 4.880 25.0 20.0 4.0 42.0
100.0 7.0 5.130 25.0 28.0 4.4 46.8 7.50 7.50 7.50

100.0 7.0 5.380 25.0 28.0 4.4 46.8


8.00 8.00 8.00
100.0 7.0 5.630 25.0 28.0 4.4 46.8
100.0 9.0 5.880 25.0 36.0 4.8 51.6 8.50 8.50 8.50
100.0 8.0 6.130 25.0 32.0 4.6 49.2
100.0 11.0 6.380 25.0 44.0 5.2 56.4 9.00 9.00 9.00

100.0 11.0 6.630 25.0 44.0 5.2 56.4


9.50 9.50 9.50
100.0 11.0 6.880 25.0 44.0 5.2 56.4
100.0 11.0 7.130 25.0 44.0 5.2 56.4 10.00
10.13 10.13 10.00
10.00
Remark: N sw =(100/L)*N a N-value of SPT is calculated from Swedish Load Sounding test qu=0.0045*Wsw+0.0075*Nsw
N sw :Nos. of half rotation per meter N=0.02W sw (kgf)+0.067N sw (For Sandy Soil) qu=Unconfined compressive strength (kgf/cm2)
N a :Nos.of half rotation for each length N=0.03W sw (kgf)+0.050N sw (For Clayey Soil) DS-Disturbed Sample
W sw :Weight(kg)

Fukken Co., Ltd. (Yangon Branch), www.fukkenmyanmar.com


SWEDISH LOAD SOUNDING TEST
Location SW Test for Relay House and Sub Signal House in Yangon-Mandalay Railway Project (Darbain Station) Date 15.05.2020
Point No. SWT-03 Elevation 5.128 m Operator YMN-I & MMH

N value
Bearing BORING LOG (ESTIMATE SOIL LAYER) Weather Sunny Water Level GL- 1.3 m
from

SPT N value

from swedish
Capacity Depth Wsw (kg) Nsw
W sw Na N sw

Soil Name

sounding
Depth (m)
Depth L sewdish

Thickness

N value
m

GL- (m)
Description

(m)

Depth
sounding

Scale

Scale
(kg) (m) (cm) qa (kN/m2) 0 5 15 25 50 75 0 50 100 200 300 400 500 600

0.00
100.0 12.0 7.380 25.0 48.0 5.4 58.8
100.0 13.0 7.630 25.0 52.0 5.6 61.2 0.50 0.50 0.50
100.0 12.0 7.880 25.0 48.0 5.4 58.8
100.0 14.0 8.130 25.0 56.0 5.8 63.6 1.00 1.00 1.00

100.0 14.0 8.380 25.0 56.0 5.8 63.6


1.50 1.50 1.50
100.0 13.0 8.630 25.0 52.0 5.6 61.2
100.0 15.0 8.880 25.0 60.0 6.0 66.0 2.00 2.00 2.00
100.0 17.0 9.130 25.0 68.0 6.4 70.8
100.0 16.0 9.380 25.0 64.0 6.2 68.4 2.50 2.50 2.50

100.0 18.0 9.630 25.0 72.0 6.6 73.2


3.00 3.00 3.00
100.0 18.0 9.880 25.0 72.0 6.6 73.2
100.0 18.0 10.130 25.0 72.0 6.6 73.2 3.50 3.50 3.50

4.00 4.00 4.00

4.50 4.50 4.50

Clayey Soil
5.00 Clayey Soil 5.00 5.00

5.50 5.50 5.50

6.00 6.00 6.00

6.50 6.50 6.50

7.00 7.00 7.00

7.50 7.50 7.50

8.00 8.00 8.00

8.50 8.50 8.50

9.00 9.00 9.00

9.50 9.50 9.50

10.00 10.13 10.13 10.00


10.00
Remark: N sw =(100/L)*N a N-value of SPT is calculated from Swedish Load Sounding test qu=0.0045*Wsw+0.0075*Nsw
N sw :Nos. of half rotation per meter N=0.02W sw (kgf)+0.067N sw (For Sandy Soil) qu=Unconfined compressive strength (kgf/cm2)
N a :Nos.of half rotation for each length N=0.03W sw (kgf)+0.050N sw (For Clayey Soil) DS-Disturbed Sample
W sw :Weight(kg)

Fukken Co., Ltd. (Yangon Branch), www.fukkenmyanmar.com


SWEDISH LOAD SOUNDING TEST
Location SW Test for Relay House and Sub Signal House in Yangon-Mandalay Railway Project (Darbain Station) Date 15.05.2020
Point No. SWT-04 Elevation 5.144 m Operator SMK, TPO & MTKK

N value
Bearing BORING LOG (ESTIMATE SOIL LAYER) Weather Sunny Water Level GL- m
from

SPT N value

from swedish
Capacity Depth Wsw (kg) Nsw
W sw Na N sw

Soil Name

sounding
Depth (m)
Depth L sewdish

Thickness

N value
m

GL- (m)
Description

(m)

Depth
sounding

Scale

Scale
(kg) (m) (cm) qa (kN/m2) 0 5 15 25 50 75 0 50 100 200 300 400 500 600

0.00
5.0 0.090 9.0 0.2 0.0
15.0 0.110 2.0 0.5 0.0 0.50 0.50 0.50
25.0 0.120 1.0 0.8 0.0
50.0 0.150 3.0 1.5 0.1 1.00 1.00 1.00

75.0 0.170 2.0 2.3 0.2


1.50 1.50 1.50
100.0 0.180 1.0 3.0 0.3
100.0 2.0 0.250 7.0 28.6 4.4 47.1 2.00 2.00 2.00
100.0 14.0 0.500 25.0 56.0 5.8 63.6
100.0 5.0 0.750 25.0 20.0 4.0 42.0 2.50 2.50 2.50

100.0 4.0 1.000 25.0 16.0 3.8 39.6


3.00 3.00 3.00
100.0 4.0 1.250 25.0 16.0 3.8 39.6
100.0 4.0 1.500 25.0 16.0 3.8 39.6 3.50 3.50 3.50
100.0 3.0 1.750 25.0 12.0 3.6 37.2
100.0 5.0 2.000 25.0 20.0 4.0 42.0 4.00 4.00 4.00

100.0 4.0 2.250 25.0 16.0 3.8 39.6


4.50 4.50 4.50
100.0 4.0 2.500 25.0 16.0 3.8 39.6

Clayey Soil
100.0 4.0 2.750 25.0 16.0 3.8 39.6 5.00 Clayey Soil 5.00 5.00
100.0 7.0 3.000 25.0 28.0 4.4 46.8
100.0 5.0 3.250 25.0 20.0 4.0 42.0 5.50 5.50 5.50

100.0 5.0 3.500 25.0 20.0 4.0 42.0


100.0 4.0 3.750 25.0 16.0 3.8 39.6 6.00 6.00 6.00

100.0 3.0 4.000 25.0 12.0 3.6 37.2


6.50 6.50 6.50
100.0 4.0 4.250 25.0 16.0 3.8 39.6
100.0 6.0 4.500 25.0 24.0 4.2 44.4 7.00 7.00 7.00
100.0 5.0 4.750 25.0 20.0 4.0 42.0
100.0 8.0 5.000 25.0 32.0 4.6 49.2 7.50 7.50 7.50

100.0 9.0 5.250 25.0 36.0 4.8 51.6


8.00 8.00 8.00
100.0 8.0 5.500 25.0 32.0 4.6 49.2
100.0 10.0 5.750 25.0 40.0 5.0 54.0 8.50 8.50 8.50
100.0 12.0 6.000 25.0 48.0 5.4 58.8
100.0 11.0 6.250 25.0 44.0 5.2 56.4 9.00 9.00 9.00

100.0 12.0 6.500 25.0 48.0 5.4 58.8


9.50 9.50 9.50
100.0 13.0 6.750 25.0 52.0 5.6 61.2
100.0 10.0 7.000 25.0 40.0 5.0 54.0 10.00 10.0 10.0 10.00
10.00
Remark: N sw =(100/L)*N a N-value of SPT is calculated from Swedish Load Sounding test qu=0.0045*Wsw+0.0075*Nsw
N sw :Nos. of half rotation per meter N=0.02W sw (kgf)+0.067N sw (For Sandy Soil) qu=Unconfined compressive strength (kgf/cm2)
N a :Nos.of half rotation for each length N=0.03W sw (kgf)+0.050N sw (For Clayey Soil) DS-Disturbed Sample
W sw :Weight(kg)

Fukken Co., Ltd. (Yangon Branch), www.fukkenmyanmar.com


SWEDISH LOAD SOUNDING TEST
Location SW Test for Relay House and Sub Signal House in Yangon-Mandalay Railway Project (Darbain Station) Date 15.05.2020
Point No. SWT-04 Elevation 5.144 m Operator SMK, TPO & MTKK

N value
Bearing BORING LOG (ESTIMATE SOIL LAYER) Weather Sunny Water Level GL- m
from

SPT N value

from swedish
Capacity Depth Wsw (kg) Nsw
W sw Na N sw

Soil Name

sounding
Depth (m)
Depth L sewdish

Thickness

N value
m

GL- (m)
Description

(m)

Depth
sounding

Scale

Scale
(kg) (m) (cm) qa (kN/m2) 0 5 15 25 50 75 0 50 100 200 300 400 500 600

0.00
100.0 13.0 7.250 25.0 52.0 5.6 61.2
100.0 12.0 7.500 25.0 48.0 5.4 58.8 0.50 0.50 0.50
100.0 12.0 7.750 25.0 48.0 5.4 58.8
100.0 14.0 8.000 25.0 56.0 5.8 63.6 1.00 1.00 1.00

100.0 15.0 8.250 25.0 60.0 6.0 66.0


1.50 1.50 1.50
100.0 16.0 8.500 25.0 64.0 6.2 68.4
100.0 15.0 8.750 25.0 60.0 6.0 66.0 2.00 2.00 2.00
100.0 17.0 9.000 25.0 68.0 6.4 70.8
100.0 18.0 9.250 25.0 72.0 6.6 73.2 2.50 2.50 2.50

100.0 21.0 9.500 25.0 84.0 7.2 80.4


3.00 3.00 3.00
100.0 22.0 9.750 25.0 88.0 7.4 82.8
100.0 23.0 10.000 25.0 92.0 7.6 85.2 3.50 3.50 3.50

4.00 4.00 4.00

4.50 4.50 4.50

Clayey Soil
5.00 Clayey Soil 5.00 5.00

5.50 5.50 5.50

6.00 6.00 6.00

6.50 6.50 6.50

7.00 7.00 7.00

7.50 7.50 7.50

8.00 8.00 8.00

8.50 8.50 8.50

9.00 9.00 9.00

9.50 9.50 9.50

10.00 10.0 10.0 10.00


10.00
Remark: N sw =(100/L)*N a N-value of SPT is calculated from Swedish Load Sounding test qu=0.0045*Wsw+0.0075*Nsw
N sw :Nos. of half rotation per meter N=0.02W sw (kgf)+0.067N sw (For Sandy Soil) qu=Unconfined compressive strength (kgf/cm2)
N a :Nos.of half rotation for each length N=0.03W sw (kgf)+0.050N sw (For Clayey Soil) DS-Disturbed Sample
W sw :Weight(kg)

Fukken Co., Ltd. (Yangon Branch), www.fukkenmyanmar.com