Professional Documents
Culture Documents
www.flowcreteasia.com
Deckshield Range Technical Profile
Application Suitability
Product Selector
Each parking facility consists of a Line
Marking
Entrance to
Shopping Malls
range of zones or areas and requires
Multi-storey
a number of surface applications as a Stair
Top Deck
Landings
result. Flowcrete offers a wide range of
Turning
flooring products to meet the surface Stairways Circles
requirements of the entire car park as
Multi-storey
well as neighbouring zones. Ramps Internal Deck
Technical Profile
Deckshield ID 032-089
Environmentally Preferred
Coating
TEMPERATURE RESISTANCE
Softens over 70˚C, hardens on cooling
BOND STRENGTH
ASTM D4541 (Pull-Off Test) >1.5 MPa* Deckshield ID cosmetically enhances and
FIRE RESISTANCE reduces noise, making multi storey car parks
brighter, safer environments to visit.
EN 13501-1 Bfl - s1
SLIP RESISTANCE
Green Label certified and low in VOCs
BS 7976-2 (typical values for Dry >40, Wet dependant
4-S rubber slider) on specification
Prepared Deckshield
Substrate SF
Technical Profile
Deckcoat EP 032-089
Environmentally Preferred
Coating
TEMPERATURE RESISTANCE
Tolerant up to 60°C
ABRASION RESISTANCE
Taber Abrader (1 kg load 80 mg loss per 1000 cycles
Environmentally Friendly: using CS10 wheels)
Green Label certified and low in
Volatile Organic Compounds (VOCs). SURFACE HARDNESS
Koenig Hardness Test 180 Seconds
Attractive:
For applications falling outside of this temperature range, please contact your local Flowcrete Technical Department.
Brightens up dull, dark and musty
car park environments. SPEED OF CURE** 10˚C 20˚C 30˚C
Resistant: Light Traffic 48 hrs 24 hrs 18 hrs
** Cure times at temperatures between 0-30˚C can be achieved by altering the quantity of catalyst used.
Resistance to chemicals, fire and Full Traffic 72 hrs 48 hrs 36 hrs
has a low slip potential. Full Chemical Cure 12 days 7 days 6 days
Chemical Resistance
Petrol Natural Quartz Deckcoat EP
Scatter Topcoat
Diesel
Antifreeze
Hydraulic Fluid
Chlorides
Prepared Deckcoat EP
Substrate Primer
For applications falling outside of this temperature range, please contact your local Flowcrete Technical Department.
Volatile Organic Compounds (VOCs). Full Traffic 48 hrs 36 hrs 24 hrs
** Cure times at temperatures between 0-30˚C can be achieved by altering the quantity of catalyst used.
and brake fluids.
Economical:
Provides value for money alongside
good performance.
Deckcoat EPW Deckcoat EPW
Basecoat Topcoat
Chemical Resistance
Petrol
Diesel
Antifreeze
Engine Oil
Chlorides
Battery Acids
Prepared Deckcoat EPW
Substrate Primer
SLIP RESISTANCE
Waterproofing:
A waterproof surface that protects the BS 7976-2 Dry >40, Wet dependant
on specification
concrete structure against weather.
ABRASION RESISTANCE
Environmentally Friendly:
Taber Abrader (1 kg load 300 mg loss per 1000 cycles
Low in Volatile Organic Compounds using CS17 wheels)
For applications falling outside of this temperature range, please contact your local Flowcrete Technical Department.
(VOCs) and solvent free..
Attractive: SPEED OF CURE** 10˚C 20˚C 30˚C
Brightens up dull, dark and musty
** Cure times at temperatures between 0-30˚C can be achieved by altering the quantity of catalyst used.
Light Traffic 30 hrs 18 hrs 12 hrs
car park environments.
Full Traffic 48 hrs 36 hrs 24 hrs
Resistant: Full Chemical Cure 12 days 7 days 6 days
Excellent resistance to chemicals,
fire and has a low slip potential.
Reduces Noise:
Higher textured finishes reduce Deckshield Deckshield Oxide Deckshield Deckshield
unwanted tyre squeal. Finish 0.8–1.2mm Scatter Finish UV (WB)
UV Stable:
100% UV light stable. Prevents
from yellowing effect.
Chemical Resistance
Petrol
Diesel
Antifreeze
Prepared Deckshield Natural Quartz Deckcoat ED
Hydraulic Fluid Substrate ED Primer 0.3–0.6mm Scatter Membrane
Chlorides
Battery Acids
*Assumes concrete compressive strength is greater than 25N/mm2
Technical Profile
Deckshield ID Rapide
TEMPERATURE RESISTANCE
Softens over 70˚C, hardens on cooling
Technical Profile
Deckshield ED Rapide
WATER PERMEABILITY
Karsten Test Nil (Impermeable)
*Assumes concrete compressive strength is greater than 25N/mm2 Protects against chemicals, fire and slips