You are on page 1of 4

Theoretical Case Practical C

S.N. Flow ratio(φ) Coefficient of friction (k) Outlet vane angle (β2=0) Efficiency (η) Coefficient of friction (k)
1 0 1 0 0 0.9
2 0.05 1 0 0.19 0.9
3 0.1 1 0 0.36 0.9
4 0.15 1 0 0.51 0.9
5 0.2 1 0 0.64 0.9
6 0.25 1 0 0.75 0.9
7 0.3 1 0 0.84 0.9
8 0.35 1 0 0.91 0.9
9 0.4 1 0 0.96 0.9
10 0.45 1 0 0.99 0.9
11 0.5 1 0 1 0.9
12 0.55 1 0 0.99 0.9
13 0.6 1 0 0.96 0.9
14 0.65 1 0 0.91 0.9
15 0.7 1 0 0.84 0.9
16 0.75 1 0 0.75 0.9
17 0.8 1 0 0.64 0.9
18 0.85 1 0 0.51 0.9
19 0.9 1 0 0.36 0.9
20 0.95 1 0 0.19 0.9
21 1 1 0 0 0.9

The efficiency was calculated using the following Efficiency vs Flow Ra


expression: 1.2
=2∗(∅−∅^2 )∗(1+𝑘∗(𝐶𝑂𝑆(𝛽_2 ))
1

0.8
Efficiency (η)

0.6

0.4

0.2

0
0 0.2 0.4 0.6 0.8 1 1.2
Flow Rate (φ)
Practical Case I- (β2=10 and k=0.9) Practical Case II- (β2=15 and k=0.8)
Coefficient of friction (k) Outlet vane angle (β2=10) Efficiency (η) Coefficient of friction (k) Outlet vane angle (β2=15) Efficiency (η)
0.17453293 0 0.8 0.26179939 0
0.17453293 0.17920106 0.8 0.26179939 0.16841036
0.17453293 0.33953886 0.8 0.26179939 0.31909332
0.17453293 0.48101338 0.8 0.26179939 0.45204887
0.17453293 0.60362463 0.8 0.26179939 0.56727701
0.17453293 0.70737262 0.8 0.26179939 0.66477775
0.17453293 0.79225733 0.8 0.26179939 0.74455108
0.17453293 0.85827877 0.8 0.26179939 0.806597
0.17453293 0.90543695 0.8 0.26179939 0.85091552
0.17453293 0.93373185 0.8 0.26179939 0.87750663
0.17453293 0.94316349 0.8 0.26179939 0.88637033
0.17453293 0.93373185 0.8 0.26179939 0.87750663
0.17453293 0.90543695 0.8 0.26179939 0.85091552
0.17453293 0.85827877 0.8 0.26179939 0.806597
0.17453293 0.79225733 0.8 0.26179939 0.74455108
0.17453293 0.70737262 0.8 0.26179939 0.66477775
0.17453293 0.60362463 0.8 0.26179939 0.56727701
0.17453293 0.48101338 0.8 0.26179939 0.45204887
0.17453293 0.33953886 0.8 0.26179939 0.31909332
0.17453293 0.17920106 0.8 0.26179939 0.16841036
0.17453293 0 0.8 0.26179939 0

fficiency vs Flow Rate

Theoretical Case
Practical Case I- (β2=10 and k=0.9)
Practical Case II- (β2=15 and
k=0.8)
Practical Case III- (β2=10 and
k=0.7)
Practical Case IV- (β2=15 and
k=0.6)

6 0.8 1 1.2
e (φ)
d k=0.8) Practical Case III- (β2=10 and k=0.7) Practical Case IV- (β2=15 and k=0
Efficiency (η) Coefficient of friction (k) Outlet vane angle (β2=10) Efficiency (η) Coefficient of friction (k) Outlet vane angle (β2=15)
0.7 0.17453293 0 0.6 0.26179939
0.7 0.17453293 0.16048972 0.6 0.26179939
0.7 0.17453293 0.30408578 0.6 0.26179939
0.7 0.17453293 0.43078818 0.6 0.26179939
0.7 0.17453293 0.54059694 0.6 0.26179939
0.7 0.17453293 0.63351204 0.6 0.26179939
0.7 0.17453293 0.70953348 0.6 0.26179939
0.7 0.17453293 0.76866127 0.6 0.26179939
0.7 0.17453293 0.81089541 0.6 0.26179939
0.7 0.17453293 0.83623589 0.6 0.26179939
0.7 0.17453293 0.84468271 0.6 0.26179939
0.7 0.17453293 0.83623589 0.6 0.26179939
0.7 0.17453293 0.81089541 0.6 0.26179939
0.7 0.17453293 0.76866127 0.6 0.26179939
0.7 0.17453293 0.70953348 0.6 0.26179939
0.7 0.17453293 0.63351204 0.6 0.26179939
0.7 0.17453293 0.54059694 0.6 0.26179939
0.7 0.17453293 0.43078818 0.6 0.26179939
0.7 0.17453293 0.30408578 0.6 0.26179939
0.7 0.17453293 0.16048972 0.6 0.26179939
0.7 0.17453293 0 0.6 0.26179939
cal Case IV- (β2=15 and k=0.6)
Outlet vane angle (β2=15) Efficiency (η)
0
0.15005777
0.28431999
0.40278665
0.50545776
0.59233331
0.66341331
0.71869775
0.75818664
0.78187997
0.78977775
0.78187997
0.75818664
0.71869775
0.66341331
0.59233331
0.50545776
0.40278665
0.28431999
0.15005777
0