You are on page 1of 2
ae M ITS U BI S H I novances ano ever aovancine MITSUBISHI ELECTRIC [CONTRACT No: JOuiENr: ISITE: MINISTRY OF ENERGY, KIFAN 'W: ME/EWIC/3485/2006-2007 KUWAIT 300/132kV SUBSTATION [PLANT ITEM. INVERTER & OIL PRESSURE ALARM PANEL TEST REPORT STOP JOINT MONITORING FOR BAY Ni INVERTER POWER SUPPLY PANEL - IPSP inverter Type Erskine PWS2160.5W Serial Number J662801/023745/0001 Input AC Rating _ 240 V, 50 Hz, 1 Phase Input DC Rating 220 V, (+20%, -15%), max 2.1 A Output AC Rating 240 V, 50 Hz, 1 Phase, max 500 VA OIL PRESSURE ALARM PANEL - OPAP Alarm Panel Type Erskine Serial Number (J6628D1/023745/0002 Input AC Rating 240 V, 50 Hz, 1 Phase Output AC Rating 110 V, 50 Hz, 1 Phase, max 500 VA. Inverter Power Supply Panel & Oil pressure Alarm Panel nat inverter input AC Voltage Check Measured [V] AC 240.9 48.99 Inverter Input OC Voltage Check Measured [V] DC 240.8 ecvs Inverter Output AC Vollage Check Measured VAC | 240.7 49.99 Input AC Voltage for Isolation Stepdown Poe Measured [V] AC 240.2 49.99 ‘Output AC Voltage from Isolation Stepdown Transformer Measured [V] AC 112.0 49.99 Inverter Power Supply Pane! focal ‘Alarms Check): ‘Alarm -Seting [Local Comm | Checked inverter On Green Ox | “Output Healthy Ok Input Voltage High & on Inverter Fail | | Ok Inverter Overload & Alarm Ok | Inverter Power Supply Panel ‘Common alarm check: "Stop Joint Monitor Power Supply Fai. Flag 30F20 at A SY. Inverter ON/OFF switch - off z q_~ OK Inverter DC supply MCB Q1 - off See i: v ‘Ok. Inverter AC supply MCB Q2 — off el 7 ‘Ok Inverter AC output MCB Q3 - off 7 ‘Ok Fuse in IPSP: F1, F3, F1-2A, F220 i zy r v Ok. Fuse in OPAP: F1-2A i oo 7 (Ok are TELCO ENGINEER FOR CLIENT (MOET Tested by Witnessed by: roy by: 16/06/2009 pF [ a M ITS U B Is H I aovanceo ano even novancine MITSUBISHI ELECTRIC CONTRACT No: [OLIENT: [SITE MINISTRY OF ENERGY, KIFAN'W" Ere Wiciseeaz2008-2007) KUWAIT 300/132kV SUBSTATION ISITE TEST SHEET No: | Page: |PANTITEM: 2253 Bae INVERTER & OIL PRESSURE ALARM PANEL TEST REPORT ‘STOP JOINT MONITORING FOR BAY No.9 Change Over Funeti : Weasured [V] | Frequency 75 tie Checked Inverter DC supply MCB Q1 - on tre Voltage 240.1 49.99 Ok Inverter DC supply MCB Q1 - off ie eats 240 49.99 Ok Oil Pressure Alarm Panel: ‘Alarm Time ‘OPAP Fogo | 6B | checked "Low Oil Pressure Alarm” 30sec | Alarm lamp (yellow) | 30F8 Ok “Low Oil Pressure Trip” '30 seo | Trip lamp (red) 30F9 | Yes Ok one MELCO ENGINEER FOR CLIENT (MoE7E! Tgsted Witnessed by: wean | 97 J

You might also like