You are on page 1of 2

T-400S Icons on the initial screen

Quick Reference Guide OME1624008

Correspond to Selected splice pro-


keys on gram /heater program Shows a power
the left hand key is displayed. source type being
pad. used.
Install the battery pack in the
correct orientation.
Shows a selected
Connector
view type.

A message for key


Strap
guidance is dis-
With the wires and strap facing played.
outside, install the battery and
connect the connector completely.

Keypad Press key to open the setup pane.

Left-hand key pad Right-hand key pad


Icons on the setup pane
Heat shrink
The Function keys Power key oven key Enter Go to Function setup Go to Pass Code entry
correspond to the screen. screen to log in to the
icons located on the Administrator mode.
left upper corner of
the screen.

Splice program

Heater program

Battery SET key


charging Choose to perform
The left-hand keys are sometimes used to status LED an arc test.
move the cursor “ ” up and down, and to left
and right. RESET key

Ver1.02
* Setup and change the Heater program in the same pro-
1 Splice program setting cedures as described below. Evaluating splice quality

Re-do splicing.

Bubble Bulging Neck-down

1. Move the cursor “ ” using 2. Select fiber profile category 3. Move the cursor “ ” to the
▼▲ keys, select splice pro- and press key. splice program you would like
to use and press key. Evaluating fiber protection sleeve
gram and press key.
* Prepare the fiber again and repeat the arc test until “Good NG
2 Perform an arc test arc state.” is displayed. 1: The shrinking sleeve is not centered over the splice

2: Bend in bare fiber

3: Incompletely shrunk (trumpet end)

1. Move the cursor “


” to “Arc 2. After “Arc Test Ready” ap- 3. Fibers are not spliced in arc
Test” using ▼ key and press 4: Bubbles on bare fiber
pears, press SET key. An tests. When the splicer shows
key. arc test is started. “Good arc state”, you can start
the splicing process.

3 Start splice process / Start heating cycle

Remove the fiber


from the splicer.
Bring the protection
sleeve over the splice
1. Press SET key to start the 2. Fusion splicing is completed. 3. Open the wind hood. A proof and load the fiber in 4. Press the Heat shrink oven
splicing process. test is automatically carried out. the heat shrink oven. key to start the heating
process.
Sumitomo Electric Industries, Ltd. reserves the right to change the specification or design without notice and may therefore not coincide with the contents of this quick reference guide. E&OE
For further detailed operating instructions and functions, please see Operation manual. The maintenance application can upgrade your splicer
to the latest software via internet. The Operation manual and the maintenance application can be downloaded via
http://www.rim-plus.sei.co.jp/index.html *AS24E161*

You might also like