HOMES 2019
Version 2, March 2019
Preface
The changes to the English Planning and SBD officers have become increasingly aware
Building Control regulations following in- of the need to consider adapted, accessible
depth reviews by the Ministry for Housing, and inclusive housing and neighbourhoods
Communities and Local Government (MHCLG) in their advice, so as not to create additional
have underlined the importance of the police barriers for disabled and older residents. Such
advice delivered over the past 30 years; inclusive design aims to remove barriers that
specifically in the form of the Secured by create undue effort and separation. It is defined
Design (SBD) initiative. The references within as a process that ensures all buildings, places,
the National Planning Policy Framework and surrounding spaces can be easily and
(NPPF) and the accompanying National comfortably accessed and used by everyone.
Planning Practice Guidance (NPPG) along The requirements and recommendations within
with those in Scotland (Scottish Planning Policy this guide are based upon sound research
– PAN 77) and Wales (Planning Policy Wales findings that have proven SBD to deliver
– TAN 12) have sought to reinforce the need significant crime reductions and cost efficiency
and importance for a safe and secure external savings for a wide range of stakeholders
environment and to this end there are specific including local authorities, housing
references to police service advice and the associations, landlords, residents and the
Police.uk website in particular. police service. The police service continually
Indeed, the government’s Chief Planning re-evaluates the effectiveness of Secured
Officer Steve Quartermain, wrote to all by Design and responds to emerging crime
planning authorities reminding them of the trends and independent research findings, in
important role the planning system plays in conjunction with industry partners, as and when
ensuring appropriate measures are in place it is considered necessary and to protect the
in relation to crime prevention and security. public from crime.
Further information is available via www. The standards contained within this document
securedbydesign.com are based upon those developed by SBD
The MHCLG has also followed Scotland’s lead with various standards owners and trade
and introduced physical security standards associations.
for new homes within Building Regulations for The police service places great importance
the first time. The Welsh Government has also upon the need to build sustainable and
decided to include a new Building Regulation inclusive communities and to raise awareness
to address the security of new homes. of the significant impact that low crime makes
This edition of the SBD guidance for domestic to the ongoing and long term sustainability of
properties has been designed to cater for the a development.
security of all new and refurbished homes Should you wish to contribute to this or
including those for disabled and older people. any of the SBD guides please contact
It incorporates the latest security standards, Secured by Design by email at
developed to address emerging criminal sbdconsultations@police-cpi.co.uk.
methods of attack, and includes references
to the Building Regulations and other statutory Secured by Design Homes 2019 is applicable
requirements across the United Kingdom. to all new SBD applications made after 1st April
2019.
2
Contents
1 Introduction 5 SECTION 2 27
2 Scope 5 19 Introduction 28
3 SBD Homes explained 5
Who should read this document? 5 SECTION 2a 29
SBD format in detail 6
20 Introduction 29
SBD graded security levels 7
Houses, bungalows and flats, apartments
SBD Gold 7
or maisonettes accessed via a private dedicated
SBD Silver 7
entrance doorset 29
SBD Bronze 7
21 Dwelling entrance doorsets 29
Secured by Design 2019 Award process
Fire rated doorsets including those
Flowchart 8
with adjacent glazing 31
4 Secured by Design National Building Approval 9 Garage doorsets, vehicular and pedestrian 32
5 How to apply for the SBD Award 9 Further requirements for all pedestrian doorsets 32
6 Construction phase security – advisory note 9 Locking systems 33
7 UK Planning and strategic policies in support Glazing in and adjacent to doorsets 33
of Secured by Design 10 Outward opening doorsets 34
England (NPPF and NPPG) 10 Door limitation and caller identification 34
Wales (PPW & TAN12) 11 Doorset Installation 34
Development Quality Requirements (DQR) Secure Mail Delivery to houses, bungalows
for social housing 11 and flats, apartments or maisonettes accessed
Welsh Housing Quality Standards (WHQS) 11 via a private dedicated entrance doorset 34
Scotland (SPP & PAN77) 11 Letter plate apertures in doors 35
Northern Ireland (DOE, PPS 7 & QD1) 12 External surface mounted letter boxes 35
Through-the-wall delivery 36
SECTION 1 14 22 Windows, roof windows and roof lights 36
Windows, roof windows and roof lights in buildings
8 Layout of roads and footpaths 14
containing multiple dwellings or bedrooms 38
Through-roads and cul-de-sacs 14
Fire rated windows 38
Footpath design 15
Planting next to a footpath 16 23 Conservatories and sun rooms 39
Seating next to a footpath 16 24 Lightweight framed walls in houses and
Lighting of footpaths 16 buildings containing multiple dwellings
Footpaths on phased developments 17 or bedrooms 39
9 Communal areas and play space 17 25 External lighting for dwellings 40
10 Dwelling Boundaries 18 Lighting in communal areas within flats/apartments 40
Front boundaries 18 26 Utility meters 40
Access gates to rear gardens 19 27 Access control and additional security
Side and rear boundaries 19 requirements for buildings containing multiple
Fencing in high crime/vulnerable areas 20 dwellings or bedrooms 41
Sub-divisional boundaries 21 Visitor door entry system 41
11 Layout and orientation of dwellings 21 Access control system 41
12 Gable end walls 21 Communal and shared entrance doorset
– physical security standards 42
13 Rear access footpaths 21
Physical security requirements for communal
14 Dwelling identification 22 entrance doorsets with no electronic visitor
15 Climbing aids 22 door entry system – 4 dwellings or less 42
16 Vehicle parking 22 Physical security requirements for communal
Motorcycle, scooter and moped parking 23 entrance doorsets with an electronic visitor
Dedicated motorcycle parking facilities 24 door entry system – 5 dwellings or more but
British Parking Association – Park Mark Award 24 less than 10 42
Underground car parking 24 Physical security requirements for communal
entrance doorsets with an electronic visitor
17 Planting in new developments 24 door entry system serving 10 dwellings or more,
18 Street lighting 25 but less than 25 42
3
Door entry and access control systems 43 Glazing in windows 59
Small developments (up to 25 flats/apartments, Window installation 59
bedsits or bedrooms) 43 40 Security of existing (refurbished) windows 60
Developments with more than 25 flats,
apartments, bedsits or bedrooms 44 41 Conservatories and sun rooms 60
Security compartmentation of developments 42 External lighting for dwellings 60
incorporating 25 or more flats, apartments, Lighting in communal areas within flats/apartments 60
bedsits or bedrooms 45 43 Utility meters 61
Emergency door release devices 47
44 Additional or alternative requirements for
28 Telephone and Internet Protocol (IP) new bespoke buildings containing multiple
based visitor door entry systems with dwellings or bedrooms 61
or without remote unlocking 47 Communal and shared doorset standards 61
29 CCTV and Recording 47 45 Mail delivery in bespoke buildings containing
30 CCTV management and maintenance protocols 48 multiple dwellings or bedrooms 62
31 Doorsets providing alternative access to 46 Bespoke doorsets providing alternative access
communal areas (other than the primary to communal areas (other than the primary
shared or communal access doorset) shared or communal access doorset)
including emergency egress doorsets 49 including emergency egress doorsets 62
Emergency egress doorsets from underground 47 New windows, roof windows and roof lights
car parks 49 in bespoke buildings containing multiple
Glazing in communal entrance doorsets 50 dwellings or bedrooms 62
32 Mail delivery in buildings containing multiple 48 Lightweight framed walls in bespoke dwellings 62
dwellings or bedrooms 50
49 Lighting for buildings containing multiple
Communal mail delivery 50 bespoke dwellings 63
33 Lighting for buildings containing multiple External lighting 63
dwellings 51 Internal lighting 63
External lighting 51
50 Loft hatches in communal areas 63
Internal lighting 51
34 Loft hatches in communal areas 51 SECTION 3 64
51 Additional features for the SBD Gold Award
SECTION 2b 52 or for a SBD Silver Award for a bespoke
35 Introduction 52 development 65
36 New ‘bespoke’ houses, bungalows, flats, 52 Doorsets providing access/egress from
apartments or maisonettes accessed via communal areas, houses and buildings
a private dedicated entrance doorset 52 containing multiple dwellings or bedrooms 65
Door and window materials 53 53 Additional window requirements for the
Timber products 53 SBD Gold Award 65
PVCu products 54 54 External garage doorsets 66
Aluminium products 54
55 Car parking 66
Composite products 54
Communal car parking areas 66
Steel products 54
Underground car parking 67
Doorset hardware and locking systems 55
Glazing in and adjacent to doorsets 56 56 Secure external storage facilities and
bicycle security 68
Door limitation and caller identification 56
Doorset Installation 56 External communal bicycle storage 68
37 Security of existing (refurbished) doorsets 56 57 Integral communal bin, mobility vehicles
and bicycle stores 69
38 Secure Mail Delivery to bespoke houses,
bungalows, flats, apartments or maisonettes 58 Internal communal drying rooms 69
accessed via a private dedicated entrance 59 Private external lighting and dwelling lighting 69
doorset 58 Private external lighting to common areas 69
External surface mounted letter boxes 58 Dwelling lighting 70
Through-the-wall delivery 59
60 Intruder alarms 70
39 New ‘bespoke’ windows, roof windows
and roof lights 59 Acknowledgements 71
Window hardware 59 Photo credits 71
4
1 Introduction 1.4 The environmental benefits of SBD are
supported by independent academic
1.1 Secured by Design is a police initiative research consistently proving that SBD
to guide and encourage those engaged housing developments experience up
within the specification, design and build to 87% less burglary, 25% less vehicle
of new homes, and those undertaking crime and 25% less criminal damage
major or minor property refurbishment, (Note 1.4). It also has a significant
to adopt crime prevention measures. impact on anti-social behaviour.
The advice given in this guide has been Therefore there are substantial carbon
proven to reduce the opportunity for cost savings associated with building
crime and the fear of crime, creating new homes and refurbishing existing
safer, more secure and sustainable homes to the SBD standard i.e. less
environments. Secured by Design is replacement of poor quality doors,
owned by the UK Police Service and is windows and the stolen property from
supported by the Home Office. Building within the home as a result of criminal
Control Departments in England (Part Q acts. This has been achieved through
Security – Dwellings), Scotland (Building adherence to well researched and
Standard 4.13) and Wales (Part Q effective design solutions, innovative
Security – Dwellings) all reference SBD. and creative product design coupled with
For simplicity, from this point onwards, robust manufacturing standards.
the SBD Homes Guide will refer to the Note 1.4: Research documentation can
English, Scottish and Welsh building
be found on the SBD website.
regulations collectively as UK Building
Regulations. 1.5 If you would like to apply for the Secured
by Design award, please use the ‘SBD
NB. At this time, Northern Ireland does
Homes’ application form found on our
not have a Building Regulation for the
website www.securedbydesign.com
physical security of dwellings.
1.2 The advice given by the police Crime
Prevention Design Advisor (CPDA), 2 Scope
Architectural Liaison Officer (ALO) or
Designing Out Crime Officer (DOCO) will 2.1 This edition of ‘SBD Homes’ addresses
be provided directly from the content of the community safety and security
this guide and will be dependent upon a requirements for all types of dwellings
crime risk analysis and an understanding including individual houses, housing
of local crime occurrences. Where estates, low and high rise apartment
justified by the results of a crime risk blocks (including assisted living and
analysis, some sections of this guide student accommodation).
allow for commensurate enhanced
measures to be specified by the DOCO, 2.2 The design, layout and physical security
the details of which are contained within sections of this edition can be applied to
each relevant section. both new and refurbished homes.
5
proven crime reduction methodologies
for the external environment. Following
• Home owners or occupiers – Section
1 of this document provides guidance
the withdrawal of the ‘Safer Places’ on the external environment around
document, there is now additional the dwelling, whilst Section 2 provides
information available to all UK planning detailed information regarding the
officers at www.police.uk physical requirements which may be
applied to existing homes that will
• Building Control – Section 2 provides radically improve the security of the
detailed information that may be
utilised to measure and discharge home.
developments against the security
requirements of the relevant UK
SBD format in detail
Building Regulations (see paragraph 3.2 This document is presented in three
1.1). sections:
• Developers – Major and regional Section 1: Development layout and
developers, small bespoke developers design. This section provides guidance
or individuals pursuing a self-build on all aspects of design and layout that
project can utilise SBD as a route impact on the creation of a safe and
to compliance with the security secure environments, including road
requirements of the relevant UK layout, footpath design, communal
areas, dwelling boundaries, car parking
Building Regulations (see paragraph
and lighting.
1.1).
Section 2: Physical security of the
• Social Housing providers – home. This section provides the
Compliance with SBD Homes will
‘Police Preferred Specification’ for all
continue to provide a ‘police preferred
physical security requirements for new
specification’ for all new developments or refurbished homes. It is separated
(proving compliance with the security into two sections; Section 2a reflects
requirements of the UK Building the requirements of the UK Building
Regulations – see paragraph 1.1) or Regulations and Section 2b addresses
refurbished developments. Reductions bespoke new homes and existing
in dwelling maintenance, increased homes.
tenant retention and satisfaction,
Section 3: Additional features for
reduced vacancy levels and
the SBD Gold award. The essential
sustainable low crime environments
security dwelling detail requirements
being some of the proven benefits.
in Section 2 are further enhanced by
• Private rented sector – This the requirements set out in this section.
document may be used by the private Section 3 addresses the requirements
rented sector to provide a safe for a range of additional or optional
and secure environment, increase residential features, such as enhanced
tenant satisfaction and occupancy, glazing, bicycle storage, drying rooms,
reduce maintenance and crime. The external bin stores, etc. If a development
requirements within Section 2 provide contains any of the features within
guidance for landlords who wish to Section 3, the physical security
improve the level of security within new requirements within this section should
developments (proving compliance be adhered to in order to achieve full
with the security requirements of the SBD Gold compliance.
relevant UK Building Regulations – see 3.3 Compliance with any of the following
paragraph 1.1) and the refurbishment SBD Awards satisfies the UK Building
or upgrading of existing properties. Regulations (see paragraph 1.1).
6
SBD graded security levels SBD Silver
3.4 Secured by Design has three differing 3.6 There are two routes to obtaining the
levels of security award, starting at SBD Silver Award:
the highest level (SBD Gold) which i. S
BD Silver can be awarded to new
incorporates the security of the external developments or refurbishment
environment together with the physical schemes that meet the required
security specification of the home. SBD security features particular to the
Silver offers those involved in new development contained within Section
developments, major refurbishment and 2a.
the individual the opportunity to gain an The above is the minimum qualifying
award for the level of physical security criteria for Secured by Design
provided. In addition, SBD Bronze National Building Approval see
offers a route to achieve a reasonable paragraph 4.
level of physical security for bespoke or ii. SBD Silver can also be awarded
refurbished properties where a traditional to new bespoke developments or
enhanced security product is not refurbishment schemes that meet the
available, or cannot be utilised due to required security features particular
the listed building or other conservation to the development contained within
status. Section 1, Section 2b and Section 3.
7
2019 Award Flowchart
YES NO
SBD
Is it a Application Received
Section 2a Application, SBD
Is it a Application Received
Section 2a Application,
and/or does it meet Section 2a and/or does it meet Section 2a
requirements? requirements?
YES NO YES NO
SBD Application
Is itReceived
a Section 2b Is it a Section 2b
Application, and/or Application, and/or
does it meet Section 2b does it meet Section 2b
requirements? requirements?
YES YES
YES YES NO
Notes:
1. No award for Section 1 or 3 only. 2. No other award combinations are available.
8
4 Secured by Design National 5 How to apply for the
Building Approval SBD Award
4.1 Secured by Design has developed the 5.1 Applicants should make themselves
Secured by Design National Building familiar with the relevant sections of the
Approval (SBD NBA) which provides a Secured by Design guidance contained
within this document and are strongly
structured approach to discharging the
advised to consult the Designing Out
UK Building Regulations (see paragraph
Crime Officer (DOCO) for site specific
1.1). information at the earliest opportunity
4.2 SBD NBA ensures that all suppliers of and follow the application process.
door, window and roof light products 5.2 The application form must be read in
consistently meet the requirements conjunction with the full SBD Homes
of the regulations, this minimises the document to ensure that your application
possibility of delays to the build process will comply.
due to non-compliance issues. Secured 5.3 If you are applying for Secured by
by Design will conduct all relevant Design Section 2 (SBD Silver or
due diligence checks on behalf of the SBD Bronze Award) to demonstrate
developer throughout the lifetime of compliance with the UK Building
the partnership and issue a certificate regulations (see paragraph 1.1), please
of conformity with the UK Building go to Section 2 of the application form.
Regulations (see paragraph 1.1) and 5.4 The development will be measured
the Secured by Design Silver award. against the requirements of the SBD
This police approval can be used for any award scheme current at the time the
future development built in accordance application was made. Developments
with the SBD NBA agreement to that have not started on site within 3
years of the original SBD application
discharge the UK Building Regulations
shall be subject to a new application (to
(see paragraph 1.1) and is acceptable to
the current SBD standards).
Building Control Officers and Approved
Inspectors. 5.5 Developers wishing to apply for
Secured by Design National Building
4.3 Housing Associations, social housing Approval should contact SBD directly at:
suppliers and client based specifiers can sbdnba@police-cpi.co.uk
be confident that developers with SBD
NBA membership are approved for the
design of their homes and the level of 6 Construction phase security
physical security provided is robust and – advisory note
consistent.
6.1 Unfortunately there are many crimes
4.4 The advantages for the developer
which occur during the construction
are clear; increased Pre Qualification
phase of a development; the most
Questionnaire (PQQ) scoring, reduced significant include theft of plant
bureaucracy and a reduction in the equipment, materials, tools and diesel
financial burden associated with fuel.
standards compliance, faster discharge
6.2 Secured by Design recommend that
of Building Regulation/Standards security should be in place prior and
obligations through the use of a UK during the construction phase. This
police certificate of compliance. For should include robust perimeter fencing
more information about SBD NBA please of the site and a monitored alarm system
contact us at sbdnba@police-cpi.co.uk (by a company or individual who can
9
provide a response) for site cabins and published the National Planning Policy
those structures facilitating the storage Framework (NPPF) which defines three
of materials and fuel. fundamental objectives to achieving a
6.3 The developer is advised that the name sustainable development: economic,
of the contractor and signage with social and environmental (NPPF, page
an emergency contact telephone no. 5, paragraph 8). Crime has a direct
should be displayed at several places impact on all three objectives. This has
been reinforced throughout the NPPF
on the perimeter fencing. This would
where the government makes clear its
allow the public to report suspicious
view of what sustainable development,
circumstances.
in England, means in practice for
6.4 Mobile or part time CCTV systems the planning system. Specifically,
can be used as an effective aid to Section 8 ‘Promoting healthy and safe
the security of a site and can act as a communities’, paragraph 91, states
deterrent to criminal activity. that ‘planning policies and decisions
6.5 Further advice can be obtained from should aim to achieve healthy, inclusive
your local Police DOCO and/or from the and safe places which… are safe and
BSIA Construction Site Security Guide accessible so that crime and disorder,
Document at: www.bsia.co.uk and the fear of crime, do not undermine
the quality of life or community
6.6 The developer should consult the DOCO cohesion.’
regarding the impact that any perimeter
fencing or hording may have on public 7.4 Furthermore, Section 8, paragraph 95
safety. Particular attention should be states ‘Planning policies and decisions
paid to the nature and surveillance should promote public safety and take
of adjoining footpaths and/or roads into account wider security and defence
bordering the site. requirements by:
a) a
nticipating and addressing possible
malicious threats and natural
7 UK Planning and strategic hazards, especially in locations
policies in support of where large numbers of people are
expected to congregate. Policies for
Secured by Design relevant areas (such as town centre
and regeneration frameworks),
7.1 It is important to note that crime is a
and the layout and design of
material planning consideration and is
developments, should be informed
a determining factor in gaining planning
by the most up-to-date information
consent.
available from the police and other
7.2 The police service has worked in agencies about the nature of potential
partnership with the governments, threats and their implications.
assemblies and Local Authorities This includes appropriate and
throughout the United Kingdom to proportionate steps that can be taken
incorporate designing out crime to reduce vulnerability, increase
principles within strategic policy and resilience and ensure public safety
planning guidance documents. The and security; and
following sections describe the strategic
b) r ecognising and supporting
guidance in support of Secured by
development required for operational
Design in England, Wales, Scotland and
defence and security purposes, and
Northern Ireland.
ensuring that operational sites are
not affected adversely by the impact
England (NPPF and NPPG) of other development proposed in the
7.3 The Government has recently area.’
10
7.5 With the publication of the accompanying 7.8 Technical Advice Note (TAN) 12:
National Planning Practice Guidance Design, provides advice for all those
(NPPG) (Note 7.5) the government has involved in the design of development
reiterated that designing out crime and on how good sustainable design can be
designing in community safety should be facilitated through the planning system.
central to the planning and delivery of TAN 12 reminds practitioners that local
new development. authorities (including National Park
Specifically the Planning Practice Authorities) are required to have due
Guidance on Design reminds regard to crime and disorder prevention
practitioners that local authorities are in the exercise of their functions under
duty bound to adhere to Section 17 Section 17 of the Crime and Disorder Act
of the Crime and Disorder Act 1998 1998. TAN 12 recognises the Secured
and exercise their functions with due by Design initiative as a standard
regard to their likely effect on crime and that has been shown to reduce crime
disorder, and do all that they reasonably (particularly residential burglary) and the
can to prevent crime and disorder. impact of crime upon neighbourhoods.
Furthermore, practitioners are also
reminded that the prevention of crime Development Quality
and the enhancement of community Requirements (DQR) for social
safety are matters that a local authority housing
should consider when exercising its 7.9 The Welsh Government has determined
planning functions under the Town and that all new social housing must be built
Country Planning legislation. to Secured by Design (Gold) standards.
Note 7.5: The reference to Design within
the NPPG can be found at: https://www. Welsh Housing Quality Standards
gov.uk/guidance/design#the-importance- (WHQS)
of-good-design 7.10 All existing social housing stock
must meet the requirements of the
Wales (PPW & TAN12) WHQS by 2020. Within the ‘Safe and
7.6 Planning Policy Wales (PPW) Secure’ section of the WHQS there is
sets out the Welsh Government’s a requirement for the physical security
national planning policy on promoting of dwellings to meet those within the
sustainability through good design. It Secured by Design scheme.
categorises five key aspects (Access,
Character, Community Safety, Scotland (SPP & PAN77)
Environmental Sustainability and 7.11 Scottish Planning Policy’s (SPP)
Movement) and provides guidance on Planning Policy Note 77 (PAN 77)
how to respond to them following an highlights the positive role that planning
appraisal of the context. can play in helping to create attractive
7.7 In relation to designing out crime, PPW well-managed environments which
states that crime and prevention and discourage antisocial and criminal
fear of crime are social considerations behaviour. It comments that new
to which regard must be given by local development should be located and
planning authorities in the preparation designed in such a way as to deter
of development plans. They should such behaviour and acknowledges
be reflected in any supplementary that poorly designed surroundings can
planning guidance, and may be material create feelings of hostility, anonymity
considerations in the determination of and alienation which can have significant
planning applications. The aim should be social, economic and environmental
to produce safe environments through costs leading to environments that are
good design. desolate.
11
7.12 It identifies planning as an important
mechanism to the creation of safer
places that can make a significant
contribution to reducing the fear and
incidence of crime. It calls for a co-
ordinated approach between local
authorities, the police, the community,
and any other relevant stakeholders,
as being a vital factor in the successful
delivery of safer places.
Northern Ireland
(DOE, PPS 7 & QD1)
7.13 Planning Policy Statement 7 (PPS 7)
from the Department of the Environment
– Planning Service (DOE) makes it
clear that the quality of a residential
environment is crucial to the long-term
sustainability of the development by
helping it to reduce crime and anti-social
behaviour.
7.14 It further comments that incorporating
sensible security measures during the
extension or refurbishment of buildings
has been shown to reduce levels of
crime and the fear of crime. By bringing
the crime prevention experience of
the police more fully into the planning
and design process, a balance can be
achieved between safety and security.
7.15 Policy QD1: Security from Crime,
seeks to provide a feeling of security
and a sense of vitality in all parts of the
development. In particular it comments
on the need to create private space to
the rear of dwellings and the importance
of natural surveillance of open spaces
and pedestrian routes. It adopts a firm
stand against any proposals that would
introduce potentially unfrequented or
unsupervised routes for pedestrians or
cyclists.
7.16 It states that developers and their
professional advisers should take
account of the principles offered by SBD
when preparing schemes.
12
SECTION 1
13
8 Layout of roads and footpaths behaviour, but they are no guarantee of
lower crime, which evidence proves is
8.1 Vehicular and pedestrian routes achieved primarily through the control
should be designed to ensure that and limitation of permeability.
they are visually open, direct, well Note 8.3: The Design Council’s/
used and should not undermine the CABE’s Case Study 6 of 2012 states
defensible space of neighbourhoods. that: “Permeability can be achieved in
Design features can help to identify a scheme without creating separate
the acceptable routes through a movement paths” and notes that “paths
development, thereby encouraging and pavements run as part of the street
their use, and in doing so enhance the to the front of dwellings reinforces
feeling of safety. Where it is desirable to movement in the right places to keep
limit access/use to residents and their streets animated and does not open up
legitimate visitors, features such as rear access to properties.”
rumble strips, change of road surface
(by colour or texture), pillars, brick 8.4 A review of available research in this
piers or narrowing of the carriageway area concluded that: “Neighbourhood
may be used. This helps to define the permeability… is one of the community
defensible space, psychologically giving level design features most reliably
the impression that the area beyond is linked to crime rates, and the
private. connections operate consistently in
the same direction across studies:
8.2 Defensible space has the simple aim
more permeability, more crime. Several
of designing the physical environment
studies across several decades link
in a way which enables the resident to
neighbourhood property crime rates with
control the areas around their home.
permeability versus inaccessibility of
This is achieved by organising all
neighbourhood layout. Neighbourhoods
space in such a way that residents may
with smaller streets or more one-way
exercise a degree of control over the
streets, or fewer entrance streets
activities that take place there.
or with more turnings have lower
property crime rates…” Source: Taylor
Through-roads and cul-de-sacs
R B 2002 “Crime Prevention Through
8.3 There are advantages in some road Environmental Design (CPTED): Yes,
layout patterns over others especially No, Maybe, Unknowable, and all of the
where the pattern frustrates the above” in Bechtel RB (ed) “Handbook of
searching behaviour of the criminal Environmental Psychology”, John Wiley,
and their need to escape. Whilst it is New York, Pages 413 – 426. Cited by
accepted that through routes will be Professor Ted Kitchen Sheffield Hallam
included within development layouts, the University 2007.
designer must ensure that the security of
the development is not compromised by 8.5 Cul-de-sacs that are short in length and
excessive permeability, for instance by not linked by footpaths can be very safe
allowing the criminal legitimate access to environments in which residents benefit
the rear or side boundaries of dwellings, from lower crime.
or by providing too many or unnecessary 8.6 However, research shows that
segregated footpaths (Note 8.3). the benefit of a cul-de-sac can be
Developments that promote intuitive compromised if one or more of the
wayfinding and enhance the passive following undesirable features exists:
surveillance of the street by residents
within their homes and high levels of
• backing onto open land, railway lines,
canal towpaths etc.;
street activity are desirable as they
have both been proven to deter criminal • are very deep (long);
14
• linked to one another by footpaths • wide;
(leaky cul-de-sacs); • well lit (see paragraphs 8.19 to 8.21);
• poorly lit • devoid of potential hiding places;
8.7 Cul-de-sacs that connect by footpaths • overlooked by surrounding buildings
to other parts of a development, often and activities;
referred to as ‘leaky cul-de-sacs’,
experience the highest levels of crime
• well maintained so as to enable natural
surveillance along the path and its
when compared to crime levels within
borders.
a true cul-de-sac. Crime in this kind of
design can be 110% higher than crime 8.11 Physical barriers may also have to
in a true cul-de-sac and therefore should be put in place where ‘desire’ lines
be avoided. (unsanctioned direct routes) place
users in danger, such as at busy road
Footpath design junctions. It is important that the user
has good visibility along the route of
8.8 Routes for pedestrians, cyclists and
the footpath. The footpath should be as
vehicles should be integrated and
much ‘designed’ as the buildings.
assist easy, intuitive wayfinding through
the application of inclusive design by 8.12 Where isolated footpaths are
increasing activity and therefore natural unavoidable, and where space permits,
surveillance, a proven deterrent to crime they should be at least 3 metres wide (to
and anti-social behaviour. allow people to pass without infringing
personal space and to accommodate
8.9 Public footpaths should not run to the
passing wheelchairs, cycles and mobility
rear of, and provide access to gardens,
vehicles). If footpaths are designated as
rear yards or dwellings as these have
an emergency access route they must
been proven to generate crime.
be wide enough to allow the passage
8.10 Where a segregated footpath is of emergency and service vehicles and
unavoidable, for example a public right have lockable barriers.
of way, an ancient field path or heritage
8.13 The creation of new pedestrian subways
route, designers should consider making
should be avoided. However, if the
the footpath a focus of the development
subway is already in existence and it
and ensure that they are:
is necessary to retain it, it should be
• as straight as possible; well-lit with vandal resistant lighting
15
(see paragraph 8.19), be as wide and view. This does not prevent planting, but
as short as possible, with a clear line will influence the choice of species and
of sight to the exit. Chamfering the the density of planting. Public footpaths
access points can help reduce areas of should not run immediately next to
concealment. Radius (convex) entrance/ doors and windows, therefore defensive
exit walls can reduce the length of space should be created to separate
the subway and the opportunity for a path from a building elevation. This
inappropriate loitering. The designer is particularly important in areas with a
should consider wall finishes that enable known graffiti or anti-social behaviour
easy removal of graffiti. problem.
26
SECTION 2
27
19.4 All standards quoted within Section 2 of
19 Introduction this document are assumed to be the
latest version, revision or amendment.
19.1 The recent recognition that security
Earlier standards/versions will not be
forms part of a sustainable and vibrant
valid or acceptable 12 months from
development has been demonstrated the publication date of the succeeding
by the inclusion of a Building Regulation amendment, revision or standard unless
in England and Wales. Part Q of otherwise stated within this document.
Schedule 1 to the Building Regulations
in both countries specifically states 19.5 At several points within this document
that ‘Reasonable provision must be a requirement is made for products to
be ‘Certificated’ to relevant standards.
made to resist unauthorised access...’
It is advisable that specifiers confirm
The importance of security within new
with the DOCO that their preferred
housing developments has also been
product(s) meets the required SBD
recognised by the Scottish Government
standards before purchasing. It should
since 2010 within the Scottish Building
be understood that any documentation
Standard 4.13 – Security, which at submitted for SBD accreditation should
clauses 4.13.1 and 4.13.2 outline clearly show the certification body
the requirement for door and window name, scope of certification and the
security. This section of SBD Homes manufacturer/fabricator of the product
should therefore be read in conjunction to be installed within the development.
with the above documents. Documentation that is provided bearing
19.2 The physical security standards outlined the name of a component or system
within this section of Secured by Design, manufacturer will only be acceptable
together with those of Sections 1 and within Section 2b of this guidance
3 of this document, also indicate the document.
requirements needed in order for a 19.6 Section 2 is divided into two parts
development to achieve the SBD Gold (Section 2a and Section 2b). Section
Award. 2a provides the ‘Police Preferred
Specification’ for new build homes and
19.3 The experience gained by the UK
major refurbishments and Section 2b
police service over the past 30 years
provides a specification for new bespoke
in this specific subject area has led
homes and the upgrading of existing
to the provision of a physical security
homes.
requirement considered to be more
consistent than that set out within
UK Building Regulations; specifically
the recognition of products that have
been tested to the relevant security
standards but crucially are also fully
certificated by an independent third
party, accredited by a United Kingdom
Accreditation Service (UKAS) Notified
Body. This provides assurance that
products have been produced under a
controlled manufacturing environment
in accordance with the specifier’s
aims and minimises misrepresentation
of the products by unscrupulous
manufacturers/suppliers and leads to
the delivery, on site, of a more secure
product.
28
SECTION 2a
meets all of the specified Building
20 Introduction Regulations, specifiers are reminded
that they have an obligation to ensure
20.1 This section provides technical guidance
compliance.
on the ‘Police Preferred Specification’ for
new dwellings including those dwellings 20.5 Where there is a client led requirement
formed by a material change of use and for SBD accreditation, compliance with
extensions to existing homes. If adhered this section alone will result in a Secured
to, this will ensure compliance with the by Design Silver Award, however when
UK Building Regulations (see paragraph combined with compliance to Section 1,
1.1). Please note: the Building and where applicable the relevant parts
Regulations (England and Wales) do of Section 3, a Secured by Design Gold
not address the security of extensions to Award can be achieved.
existing buildings or replacement doors 20.6 This section may also be used by
or windows, however the standards organisations or individuals that are
contained within this document can be undertaking both major and minor
utilised by builders or individuals who refurbishment of one or more dwellings.
wish to ensure that good security is
incorporated within the home. 20.7 Section 2a of this guidance document is
further separated into two areas:
20.2 Compliance with the Scottish Building
Standard 4.13 is applicable to all • Houses, bungalows and flats or
dwellings and includes extensions maisonettes accessed via a private
to existing dwellings and can be dedicated entrance doorset;
demonstrated through the application • Buildings containing multiple dwellings
of the standards contained within this or bedrooms accessed from a semi-
section. private area and served by a shared or
20.3 Whilst this guidance document primarily communal entrance doorset.
concentrates on security (UK Building
Regulations – see paragraph 1.1), it Houses, bungalows and flats,
should be noted that the design and apartments or maisonettes
specification may impact on other accessed via a private dedicated
Building Regulations. It is imperative entrance doorset
that products utilised within a Secured
by Design development comply with
all relevant Building Regulations in full. 21 Dwelling entrance doorsets
It should be noted that the Building
Regulations in all four UK nations 21.1 The term “doorset” refers to a door,
are considered equal to one another, frame, locks, fittings and glazing as one
i.e. no one Building Regulation takes combined unit.
precedence over another, for example 21.2 Door frames must be securely fixed to
fire rated doorsets (Part B) in England the building fabric in accordance with
must also meet all other relevant the manufacturer’s instructions and
Building Regulations e.g. Parts E, L, M specifications. These should be made
and Q in one product. available to the DOCO upon request if
20.4 Whilst Designing Out Crime Officers the need for visual confirmation is felt
will not require evidence that a product necessary.
29
21.3 All doorsets allowing direct access into Note 21.3b: PAS 24:2016 embodies two
to the home, e.g. front and rear doors, routes to compliance:
interconnecting garage doorsets, French
doors, bi-fold or sliding patio doorsets,
• The traditional UK PAS 24 test
methodology; or
dedicated private flat or apartment
entrance doorsets, easily accessible • Via BS EN 1627:2011 Resistance
balcony doorsets (Note 21.3a), etc., shall Class 3 (which references BS EN
be certificated to one of the following 1628, 1629 & 1630), with additional
standards: test criteria to address known criminal
methods of entry within the UK (which
• PAS 24:2016 (Note 21.3b); or are not sufficiently catered for within
• STS 201 Issue 7:2015 (Note 21.3c); or the European Standards).
• LPS 1175 Issue 7.2:2014 Security NB: If manufacturers wish to use the
Rating 2+ (Note 21.3d); or European Standards as a route to
compliance to PAS 24:2016, then all
• LPS 1175 Issue 8:2018 Security testing must be conducted in accordance
Rating A3+; or with the latest published version of the
• STS 202 Issue 6:2015 Burglary Rating ‘UK Police Service Secured by Design
2 (Note 21.3d); or (SBD) Interpretation Document for BS
EN 1627:2011, BS EN 1628:2011, BS
• LPS 2081 Issue 1.1:2016 Security EN 1629:2011 and BS EN 1630:2011.’
Rating B (Notes 21.3d and 21.3e)
This document can be found on the
Note 21.3a: Easily accessible is defined Secured by Design website within the
within Approved Document Q Appendix SBD Standards Explained section.
A:
Note 21.3c: STS 201 is the unique
• A window or doorset, any part of reference number for Element’s
which is within 2 metres vertically of published standard replicating the
an accessible level surface such as requirements of PAS 24:2016.
a ground or basement level, or an
Note 21.3d: LPS 1175, LPS 2081 and
access balcony; or
STS 202 are unique to the respective
• A window within 2 metres vertically of a certification bodies and incorporate a
flat roof or sloping roof (with a pitch of physical attack on the glazed areas
less than 30˚) that is within 3.5 metres within doors and windows. Specifiers
of ground level. should satisfy themselves that the
30
glazing incorporated within products fabricator supplying the finished product
certified to these standards meets the to site is required to present independent
required thermal performance and third party dual certification from a single
durability requirements for the specified UKAS accredited certification body
application. for both elements. This is in order to
Note 21.3e: LPS 2081 is a standard minimise the likelihood of a doorset being
that utilises a similar methodology to presented in two differing configurations
that used in LPS 1175, but the attacks for separate fire and security tests and
are designed to use stealth (low noise then later being misrepresented as one
levels). It may therefore be more product meeting both requirements. All
applicable to residential applications. door styles and components, will need
21.4 The benefits of third party certification to be adequately described within the
are recognised within the UK Building scope of certification and accompanying
Regulations (see paragraph 1.1). Technical Schedule. (Note 21.5).
Any test evidence used to confirm Note 21.5: Any component part of the
the security of a construction should doorset that is changed for any reason
be carefully checked to ensure that
must be assessed by the certification
it demonstrates compliance that is
body to ensure compliance with both fire
adequate and that applies to the
and security.
intended use. Evidence passed from
one organisation to another can become 21.6 Any adjacent side panel (glazed or
unreliable if important details are lost. non-glazed) to a fire rated doorset must
Small differences in construction can be included within the dual scope of
significantly affect the performance of a certification for that doorset.
doorset or window.
21.7 The responsibility for the specification
Fire rated doorsets including those and location of fire rated security
with adjacent glazing doorsets lies with the developer or the
developer’s agent.
21.5 Where there is a requirement for a
doorset to be both fire and security rated, 21.8 The role of the flat or apartment entrance
e.g. flat or apartment entrance doorsets, doorset (the final doorset providing
interconnecting garage doorsets access to the dwelling) should not be
and some doorsets aiding security underestimated in the event of a fire. It is
compartmentation, the manufacturer or therefore imperative that fire resistance
31
is professionally assessed/measured.
Part B of the current Building Regulations
• BS 6510: 2010 (Steel)
and the associated guidance in Approved • BS 644: 2012 (Timber)
Document B state such doorsets should • BS 8529: 2017 (Composite)
achieve at least 30 minutes fire resistance. 21.13 There have been numerous examples
Additional requirements are also listed for of doorsets failing in use due to poor
smoke leakage.
general performance leading to
properties becoming insecure therefore
Garage doorsets, vehicular and doorsets should also be certificated to BS
pedestrian 6375 Part 1, 2 and the relevant sections
21.9 Approved Document Q, Section 1 of Part 3. Specifiers are reminded that
(General), clause 1.1, states that where there are numerous classifications within
access to the dwelling can be gained BS 6375 and therefore it is not possible
via an interconnecting doorset from for this document to be prescriptive. It
the garage, then either the garage is therefore important that the correct
doorset/s (vehicular and pedestrian) duty, weather and performance levels
or the interconnecting doorset can are selected to address the intended
be designated as the secure doorset. use and location of the doorset (with
Pedestrian doorsets (interconnecting or particular attention to features that can
garage access doorsets) shall meet the create barriers, including thresholds and
requirements in paragraph 21. opening forces).
21.10 Where a vehicular access doorset 21.14 Suitably qualified and recognised third
provides the primary security in this area party Certification Authorities (Note
of the building it should be certificated to: 21.14a) for all the standards in this
• LPS 1175 Issue 7.2:2014 Security guidance document can be found within
the SBD website:
Rating 1+ (or above); or
• LPS 1175 Issue 8:2018 Security Rating www.securedbydesign.com
1+/A1+ (or above); or Alternative compliance may be possible
• STS 202, Burglary Rating 1+ (or above); in certain circumstances (Note 21.14b).
or Note 21.14a: Certificated products
• LPS 2081 Issue 1 (2015) Security undergo continuous assessment,
Rating A. including factory production controls
and audits and regular audit testing, to
21.11 It is recommended that if the primary
ensure product standards and product
security is provided by the vehicular
consistencies are maintained.
doorset, together with any external
pedestrian doorsets, that the Note 21.14b: Alternative compliance can
interconnecting doorset is fitted with a either be demonstrated by SBD Licence
Kitemarked or alternatively certificated holders that have reached an advanced
lock to BS 3621/BS 8621 (single stage of the certification process with
point locking), or PAS 3621/PAS 8621 one or more of the bodies listed within
(multipoint locking). the Secured by Design website. All such
cases must be verified by Secured by
Further requirements for all Design staff. Alternatively, third party
pedestrian doorsets accreditation via a suitably qualified
21.12 Doorsets shall also be certificated to and accredited certification body that
the following relevant material specific has signed the EA MLA (European co-
standards: operation for Accreditation Multi-lateral
Agreement) may be acceptable. The
• BS 7412:2007 (PVC-U) DOCO may refer such cases to SBD
• BS 4873: 2016 (Aluminium) management for verification.
32
21.15 Unless the developer has been awarded understands how to operate the locking
Secured by Design National Building system, clear operating instructions must
Approval (SBD NBA) the DOCO shall be attached to the inner face of the door
be supplied with proof of certification (Note 21.18). The instructions should be
by the developer or the developer’s easily removable by the end user.
agent, this must also include the ‘Scope Note 21.18: The purpose of providing
of Certification’ (a technical schedule the end user with operating instructions
listing all of component parts of the is to reduce the number of burglaries
certificated doorset range), unless the through otherwise secure doorsets,
supplier is a member of the Secured because the full locking system has
by Design Licensing Scheme and the not been engaged. This is particularly
doorset can be identified on the SBD problematic with split spindle multi-point
website. Specifiers are reminded that locking systems, where, for example,
this information must be supplied to the the occupier goes to bed at night without
DOCO prior to the SBD certificate being engaging the locks in the mistaken
awarded and must be in the name of the belief that leaving the door closed only
manufacturer or fabricator supplying the on the latch (live bolt) is sufficient. The
finished product to site. instructions should point out that the
21.16 Specifiers are reminded that products doorset is not totally secure unless the
tested to PAS 24:2016 (Clause 5) and locking system is fully engaged. The
subsequently claiming compliance with method of attachment of these operating
this standard shall be permanently instructions and the medium used to
marked in a position that is visible and carry them is for the door manufacturer
readily accessible when the product is to decide but are not intended to be
open and not visible when the product is permanent.
closed, with the following information:
Glazing in and adjacent to
• Number and date of the standard; doorsets
• The date of manufacture of the product 21.19 Any glazing within PAS 24:2016 or
(at least the year and quarter);
STS 201 Issue 4: 2012 certificated
• The name or trademark of the doorsets, including glazed panels/side
manufacturer or other means of lights adjacent to doors installed within
identifying the manufacturer; an integral door frame and windows
• The classification of the doorset e.g. adjacent to doorsets (within 400mm),
D or W. must incorporate one pane of laminated
glass meeting, or exceeding, the
Important: If a doorset claiming to requirements of BS EN 356:2000 class
meet these standards is not marked P1A (Note 21.19). NB. This is a specific
in accordance with PAS 24 (Clause 5), requirement within PAS 24:2016, which
it does not meet the standard. is referenced within the UK Building
21.17 Secured by Design recommends Regulations (see paragraph 1.1).
doorsets are marked on the head (top) of Note 21.19: There is no specific
the door to avoid any identifying labels/ requirement to install laminated glazing
data being removed during the final site on the inner or outer face of a double
cleaning process. Please note that this glazed unit. However specifiers may
is a requirement within PAS 24 (Clause wish to take into consideration the fact
5) and STS 201 and is an additional that toughened glass is usually more
requirement to CE marking. resistant to accidental damage by blunt
objects such as a football and therefore
Locking systems may be best placed on the external
21.18 To ensure that the end user of the door face of the double glazed unit. It is
33
recognised however that there are many 21.24 A door viewer meeting the requirements
other factors that may also need to be with the Door & Hardware Federation
considered such as thermal efficiency, Technical Specification 002 (TS 002)
aesthetics and the requirement for standard must be fitted between
privacy or obscured glazing, which will 1200mm and 1500mm (in addition to
influence the specifier’s decision. 1050mm for wheelchair accessible
dwellings) from the bottom of the door,
21.20 The above requirement is not necessary
this is not required if the doorset is
for doorsets certificated to LPS 2081,
installed with clear glazing or if there
LPS 1175 or STS 202 as glazing security
is a side panel with clear glazing (see
requirements are significantly more Approved Document Q, Section 1:
stringent within these standards, even Doors, paragraph 1.4).
at the lowest levels. However if there
is an adjacent window then the glazing Doorset Installation
must meet the requirements of BS EN
356:2000 class P1A. 21.25 Door frames must be securely fixed to
the building fabric in accordance with
21.21 If glazed panels/windows adjacent to the manufacturer’s instructions and
doors are installed as an integral part specifications. These should made
of the door frame then they must be available to the DOCO upon request if
shown to be part of the manufacturer’s the need for a visual confirmation is felt
certificated range of doorsets and be necessary.
specifically referenced within the Scope
21.26 Doorsets that are hidden from public
of Certification. Alternatively, where
view, typically side or back doors, should
they are manufactured separately
not be recessed more than 600mm. This
from the door frame, they must meet
requirement is not applicable to doorsets
the requirements of a ‘window’ see
located in wide recesses that are
paragraph 22. In such cases the window
located within public view (Note 21.26).
shall be securely fixed to the doorset
However, no doorset should be recessed
(in accordance with the manufacturer’s by more than 1000mm.
specifications).
Note 21.26: For the purposes of this
Outward opening doorsets guidance document a doorset is
considered to be within ‘public view’
21.22 Outward opening doorsets installed when it can be seen from the street.
within SBD developments must
specifically form part of the certificated Secure Mail Delivery to houses,
product range. bungalows and flats, apartments or
maisonettes accessed via a private
Door limitation and caller dedicated entrance doorset
identification
21.27 There are increasing crime problems
21.23 A door chain or opening limiter associated with letter plate apertures,
meeting the requirements of the Door such as identity theft, arson, hate
and Hardware Federation Technical crime, lock manipulation and ‘fishing’
Specification 003 (TS 003) must be for personal items (which may include
installed on the doorset to which a caller post, vehicle and house keys, credit
can be expected, normally the front door cards, etc). In order to address such
(see Approved Document Q, Section 1: problems SBD strongly recommends,
Doors, paragraph 1.4). All such devices where possible, mail delivery via a
should be suitable for the door material secure external letter box meeting the
to which they are fitted and be installed requirements of the Door and Hardware
in accordance with the manufacturer’s Federation standard Technical Standard
recommendations. 009 (TS 009) or delivery ‘through the
34
wall’ into a secure area of the dwelling. It is important that such products are
These should be easily accessible i.e. at installed strictly in accordance with the
a suitable height for a range of users. manufacturer’s instructions.
21.32 Specifiers attention is drawn to the
Letter plate apertures in doors Door Hardware Federation’s Technical
21.28 Where a letter plate aperture is required Standard 008 (TS 008) which is also
to be installed within a doorset it must referenced within Approved Document Q
form part of the certificated doorset (Section 1, paragraph 1.3). Additionally,
range. BS EN 13724 which is referenced within
TS 008 provides details regarding the
21.29 Specifiers and doorset manufacturers test methods and requirements for
are advised that if a letter plate was not private letter boxes and letter plates. One
present in the doorset when it was tested of its stipulated criteria is that the lowest
to any of the standards in paragraph mailbox aperture should be no lower
21.3, or has not been independently 700mm from delivery floor level and the
assessed by a certification authority and height of the highest mailbox aperture
included within the Scope of Certification should be no higher than 1700mm from
of the doorset, then the subsequent delivery floor level.
installation of a letter plate will invalidate
the certificated doorset. External surface mounted letter
21.30 Doorsets certificated to LPS 2081, boxes
LPS 1175 and STS 202, with a letter 21.33 Where a surface mounted letter box is to
plate tested to the requirements of the be used it must be robust in construction.
Door Hardware Federation’s Technical TS 009 letter boxes offer reassurance
Standard 008 (TS 008) will be acceptable that all of the above attributes have been
when included within the Scope of met. In high crime areas TS 009 provides
Certification for the doorset. the safest means by which mail can be
21.31 Where there is a concern for arson delivered whilst eliminating the risks
attacks, or repeat arson attacks, SBD associated with letter plate apertures.
recommends either the omission of The letter box must be securely fixed to
a letter plate within a door, which is the face of the building in accordance
then replaced by an external letter box with the manufacturers specifications and
mounted on a wall or similar, or the be located in a position that benefits from
installation of an ‘anti-arson’ container. natural surveillance.
35
Through-the-wall delivery • LPS 2081 Issue 1.1:2016 Security
21.34 Where there are design constraints that Rating A.
prevent a letter plate with a security Note 22.2a: Easily accessible is defined
cowl being installed within a door e.g. within Approved Document Q Appendix A
narrow hallway, or where it is undesirable as:
to install a surface mounted secure
mail box e.g. in a corridor, it may be • A window or doorset, any part of
preferable to provide ‘through-the-wall’ which is within 2 metres vertically of
mail delivery into a secure internal letter an accessible level surface such as a
box. Such a box must incorporate the ground or basement level, or an access
same design features as described balcony, or
above for a surface mounted box. Anti- • A window within 2 metres vertically of a
arson design features may also be flat roof or sloping roof (with a pitch of
advised if such crime risks are present. less than 30˚) that is within 3.5 metres
21.35 Products meeting the requirements of the of ground level.
Door & Hardware Federation Technical Note 22.2b: PAS 24:2016 embodies two
Specification 008 (TS 008) provide routes to compliance:
reassurance that ‘through the wall’ letter
boxes offer similar security attributes
• The traditional UK PAS 24 test
methodology; or
as secure letter plates and many of the
attributes that an external letter box • Via BS EN 1627:2011 Resistance
conforming with TS 009 would provide Class 2N (which references BS EN
(also see paragraph 21.32). 1628, 1629 & 1630), with additional
test criteria to address known criminal
methods of entry within the UK (which
22 Windows, roof windows are not sufficiently catered for within
and roof lights the European Standards). Please note:
whilst the UK have selected Class 2N
22.1 Window frames must be securely fixed (and hence there is no performance
to the building fabric in accordance requirements required under the
with the manufacturer’s instructions European standard), there is still a
and specifications. These should made requirement for all emergency egress
available to the DOCO upon request if windows without locking hardware
the need for a visual confirmation if felt to be installed with laminated glass
necessary. conforming to BS EN 356 Class P1A
(min).
22.2 All easily accessible (Note 22.2a)
windows (including easily accessible Note 22.2c: STS 204 is the unique
roof lights and roof windows) shall reference number for Element’s
be certificated to one of the following published standard replicating the
standards: requirements of PAS 24:2016.
Note 22.2d: Specifiers and DOCOs are
• PAS 24:2016 (Note 22.2b); or reminded that a requirement for windows
• STS 204 Issue 6:2016 (Note 22.2c); or to meet LPS 1175 or STS 202 in a
• LPS 1175 Issue 7.2:2014 Security residential situation will be exceptionally
Rating 1 (Note 22.2d); or rare and can only be justified by a
detailed crime risk analysis indicating
• LPS 1175 Issue 8:2018 Security Rating that the resident is at extreme risk.
1/A1; or
Please also note that some products may
• STS 202 Issue 7:2016 Burglary Rating be acceptable when tested to an earlier
1; or version of the standard.
36
22.3 All easily accessible windows should within BS EN 6375 and therefore it is
incorporate key lockable hardware not possible for this document to be
unless designated as emergency egress prescriptive. It is therefore important
routes within the Building Regulations. that the correct duty, weather and
22.4 Windows that form part of a designated performance levels are selected to
fire escape route, as determined by address the need/location of the window.
the Fire Safety Officer, may require 22.9 Suitably qualified and recognised third
non-key locking hardware. In these party Certification Authorities (Note
circumstances laminated glass to BS EN
22.9a) for all the standards in this
356:2000 class P1A will be required.
guidance document can be found within
22.5 If however the Fire Safety Officer the Secured by Design website;
accepts locking hardware as part of the www.securedbydesign.com
designated fire escape route, then fire
resistant glass may be required. Note: 22.9a: Certified products undergo
continuous assessment, including factory
22.6 Windows that are not easily accessible
production controls and audits and
will require either lockable hardware or
regular audit testing, to ensure product
an opening restrictor in the interests of
standards and production consistencies
child safety.
are maintained.
22.7 Windows must also be fit for purpose
and shall be certificated to the relevant Note: 22.9b: Alternative compliance can
material standard i.e.: either be demonstrated by SBD licence
holders that have reached an advanced
• BS 7412:2007 (PVC-U) stage of the certification process with
• BS 4873: 2016 (Aluminium) one of the above bodies. All such cases
• BS 6510: 2010 (Steel) must be verified with PCPI. Alternatively
• BS 644: 2012 (Timber) third party accreditation via a Notified
• BS 8529: 2017 (Composite) Certification Body that has signed the
EA MLA (European co-operation for
22.8 The following performance requirements
are also required: Accreditation Multilateral Agreement)
may be acceptable if such a body is also
• BS 6375 parts 1 & 2 (Note 22.8) accredited to conduct such activities. The
Note 22.8: Specifiers are reminded DOCO may refer such cases to PCPI for
that there are numerous classifications verification.
37
22.10 Unless the developer has been awarded 22.13 Where automatic opening window and
Secured by Design National Building venting systems controlled by sensors
Approval (SBD NBA), the DOCO shall be and computers are used, for example in
supplied with proof of certification by the some eco homes or flat developments,
developer or the developer’s agent (from such opening windows or vents should
one of the bodies listed within the Secured be independently certificated to one of
by Design website, www.securedbydesign. the aforementioned security standards
com), this must also include the ‘Scope of but in situations where they are not, then
Certification’ (a technical schedule listing additional security measures are required
all of component parts of the certificated such as grilles meeting one of the security
window range), unless the supplier is standards below, to prevent the security
a member of the Secured by Design of the building being compromised
Licensing Scheme and the window can be in the event of a system failure. In
identified on the SBD website. Specifiers these circumstances, a Smoke Control
are reminded that this information must Contractor or Fire Safety Professional
be supplied to the DOCO prior to the SBD should be consulted to ensure that
certificate being awarded. any additional security measures do
22.11 Windows falling outside the scope of not compromise the smoke ventilation
the British Standard or STS Standard requirements expected under Approved
must be assessed by a UKAS accredited Document B.
organisation accredited to perform such • LPS 1175 Issue 7.2:2014 Security
an assessment against the principles of Rating 1 (Note 22.2d); or
PAS 24:2016 or STS 204 Issue 6:2016.
Any such assessment shall include the
• LPS 1175 Issue 8:2018 Security Rating
1/A1; or
appropriate fitness for purpose standard
(paragraph 22.7). The DOCO shall be • STS 202 Issue 7:2016 Burglary
supplied with proof of certification by Rating 1; or
one of the UKAS Accredited Certification • LPS 2081 Issue 1.1:2016 Security
Bodies, including the technical schedule, Rating A.
prior to the SBD certificate being awarded;
unless the supplier is a member of the Windows, roof windows and roof
Secured by Design Licensing Scheme and lights in buildings containing
the window can be identified on the SBD multiple dwellings or bedrooms
website.
22.14 All easily accessible windows, roof
22.12 Laminated glass meeting the requirements windows and roof lights in building
of BS EN 356:2000 class P1A is required containing multiple dwellings or
in the following areas: bedrooms shall meet the requirements
• any window located within 400mm of a of paragraphs 22.1 to 22.16 (inclusive).
doorset (to ensure the integrity of the
locking system); Fire rated windows
• easily accessible emergency egress 22.15 Where there is a requirement for a
windows with non-lockable hardware window to be both fire and security rated,
(a requirement of PAS 24:2016); the manufacturer or fabricator supplying
the finished product to site is required
• easily accessible roof lights with non- to present independent third party
lockable hardware. dual certification from a single UKAS
Alternatively, if the window is tested and accredited certification body for both
accredited to LPS 1175, then laminated elements. This is in order to minimise the
glass meeting the requirements of LPS likelihood of a window being presented in
1270 Issue 1.1 Security Rating 001 two differing configurations for separate
(minimum) may be used. fire and security tests and then later
38
being misrepresented as one product requirements within paragraph 21.1 to
meeting both requirements. All window 21.17 and 21.19 to 21.22.
styles and components, will need to be
adequately described within the scope of
certification and accompanying Technical 24 Lightweight framed walls
Schedule. (Note 22.15)
in houses and buildings
Note 22.15: Any component part of the containing multiple dwellings
window that is changed for any reason
must be assessed by the certification
or bedrooms
body to ensure compliance with both fire
24.1 The security of a development can be
and security.
severely compromised if lightweight
22.16 The responsibility for the specification framed walls do not offer sufficient
and location of fire rated security resilience to withstand a criminal attack;
windows lies with the developer or the this is recognised within Approved
developer’s agent. Document Q (Note 24.1). The SBD
requirements are primarily based upon
products that have been tested and
23 Conservatories proven to provide additional security.
and sun rooms Note: 24.1: See – The Building
Regulations 2010, Security-Dwellings,
23.1 Where a conservatory or sun room is Q1: Unauthorised access, Section 1:
installed then the doors and windows Doors, paragraph 1.6.
must meet the same physical security
24.2 Lightweight framed walls installed
standards as paragraphs 21.1 to
either side of a secure doorset (600mm
21.17, and 21.19 to 21.22 (doors), and
for the full height of the doorset to
paragraphs 22.1 to 22.16 (windows).
restrict access to door hardware) or
If a conservatory is installed with
polycarbonate glazing system then a walls providing a partition between two
doorset shall be installed separating dwellings, or a dwelling and shared
the conservatory from the rest of the communal space, shall meet the
dwelling, unless the roofing system requirements below:
has been certificated to one of the 24.2.1 Wall systems proven to meet the
standards referenced within paragraph requirements of the following standards
22.3. The doorset shall comply with the are preferred:
39
• LPS 1175 Issue 7.2:2014 Security Lighting in communal areas within
Rating 1; or flats/apartments
• LPS 1175 Issue 8:2018 Security Rating 25.3 24 hour lighting (switched using a
1/A1; or photoelectric cell) to communal parts of
blocks of flats will be required. It is
• STS 202 Issue 7:2016 Burglary acceptable if this is dimmed during
Rating 1.
hours of low occupation to save energy.
Specifiers and DOCOs are advised that This will normally include the communal
the correct installation of lightweight entrance hall, lobbies, landings, corridors
framed walling systems is crucial to the and stairwells and underground garaging
level of security ultimately provided, it facilities and all entrance/exit points.
is therefore recommended that they are Other areas requiring lighting will be
installed by approved installers who have indicated by the DOCO in writing. To
received appropriate training. reduce energy consumption this may be
provided by a dimming system which
24.2.2 As an alternative, although not originally
leaves luminaires on at a lower level
intended to enhance security, the
during quieter periods.
following ‘Robust Details’ have shown to
offer some resistance to intrusion: 25.4 Secured by Design encourages,
wherever possible, the use of the most
• E-WT-2 (timber wall construction); environmentally friendly light sources.
• E-WS-3 (light steel construction); Moreover the Institute of Lighting
• E-WM-20 (masonry wall construction). Professionals (ILP) currently favours
the use of good quality LED lighting and
24.2.3 A further alternative to the either one of other energy effective light sources and
the requirements above is the installation advises against the use of fluorescent
of 9mm (min) timber sheathing or lighting which is environmentally
expanded metal in the areas concerned. unsustainable for a variety of reasons
(Note 59.5). Further information is
available at: www.securedbydesign.com
25 External lighting for dwellings
25.1 Lighting is required to each dwelling 26 Utility meters
elevation that contains a doorset (Note
25.1) and can also assist in identifying the 26.1 There is no requirement for the location
door and operating locking mechanisms. of the utility meters if ‘smart meters’ are
Note 25.1: Secured by Design has utilised (remote signalling). Otherwise
not specified PIR activated security utility meters should be located outside
lighting for a number of years following the dwelling at the front or as close to the
advice from the ILP and police concern front of the building line as possible (to
regarding the increase in the fear of crime ensure they are visible in order to deter
(particularly amongst older people) due to vandalism). If located to the side of the
repeated PIR lamp activations. Research dwelling they must be as near to the front
has proven that a constant level of of the building line as possible and to the
illumination is more effective at controlling front on any fencing or gates (care should
the night environment. be taken not to provide a climbing aid).
When installed in a building containing
25.2 The use of LED light sources is a number of residencies such as flats,
recommended with a colour temperature apartments or maisonettes, the meters
of no more than 4000 Kelvin and ideally should be installed in a location that
below. This reduces blue light content access does not introduce security risks
and therefore the effects on human and to residential areas.
ecology receptors.
40
the visitor access. This should be
27 Access control and additional repeated at any subsequent communal
security requirements for entrance and landing if compartmentation
buildings containing multiple of the building is required.
dwellings or bedrooms 27.3 Visitor door entry systems shall be easy
to operate and understand and have
Definition the ability to display the image of the
caller before the call is answered, so the
27.1 A building containing multiple dwellings, resident can choose whether to answer
for the purposes of this document, may the call or not.
include flats, apartments, bedsits or
individual bedrooms accessed from a
Access control system
semi-private area and served by a shared
or communal entrance doorset including Definition
Houses in Multiple Occupation (HMO)
and student accommodation. 27.4 A proximity access control system
provides electronic access through
Visitor door entry system communal entrance doorsets. This is
generally by use of a card or key fob
Definition issued to an occupant or person such
as staff member, contractor or postal
27.2 A door entry system is a visitor system
delivery service. It grants access to
that is able to call a dwelling, whether
required areas via locked doors when
individual or served from a communal
the valid card or key fob is presented to
entrance. It shall allow a visitor to ring
a proximity reader fitted to the communal
any selected dwelling within the particular
entrance doorset. Authorised access can
system and/or building, and hold a two-
be restricted to certain times of the day
way simultaneous conversation between
the visitor and occupant of the dwelling. for some users.
It will allow the occupant to see and The access control system will have the
identify the visitor and their location, and facility to record and identify the location,
will enable the occupant of the dwelling user, type, time and date of every system
to remotely operate the electric locking event. Sufficient memory storage must
device from their room terminal, thereby be available for a period of not less
unlocking the communal entrance door(s) than 30 days. The system will be fully
associated with the action and allowing programmable, with access restricted to
41
the nominated system controller(s) who number of flats/apartments, bedsits or
will be able to manage the system via bedrooms) and therefore specifiers are
remote access in order to expeditiously again referred to the content of paragraph
delete lost or stolen proximity cards 21.1 to 21.17 and 21.19 to 21.22. for the
or key fobs and any enrolled radio requisite physical security standards.
transmitters. Radio transmitted must have
27.9 Tradesperson or timed release
individual codes, such as those used by
mechanisms are not permitted as they
access cards or key fobs. Common code
have been proven to be the cause of anti-
radio transmitters shall not be acceptable
social behaviour and unlawful access to
as they cannot be managed.
communal developments.
27.5 Electronic keys must be security
encrypted to protect against unauthorised Physical security requirements
copying, and be sufficiently robust to for communal entrance doorsets
avoid constant replacement during with an electronic visitor door entry
everyday use by the residents. system – 5 dwellings or more but
less than 10
Communal and shared entrance
doorset – physical security 27.10 Communal entrance doorsets serving
5 dwellings or more, but less than 10
standards
falling within this category shall meet the
Definition following (in accordance with Section 2A
paragraph 21):
27.6 A communal or shared entrance doorset,
including integral adjacent panels and • PAS 24:2016;
side screens, can be defined as an
external doorset leading from the street
• STS 201;
or otherwise public area to an internal • LPS 2081 Security Rating B+.
semi-private communal area providing 27.11 Where a communal entrance doorset
access to segregated flats, bedsit or serves 5 dwellings or more, but less than
individual bedrooms. They can be further 10, it is required to have a visitor door
categorized by use as follows: entry system and access control system
to enable management oversight of the
Physical security requirements security of the building.
for communal entrance doorsets
27.12 Tradesperson or timed release
with no electronic visitor door entry mechanisms are not permitted as they
system – 4 dwellings or less have been proven to be the cause of anti-
27.7 Communal entrance doorsets in blocks social behaviour and unlawful access to
serving 4 dwellings or less, over no more communal developments.
than two floors, are not required to be
27.13 Developments with more than two floors
connected to a visitor door entry system
are required to have a visitor door entry
and access control system, and can be
system and access control system
controlled by non-electronic keys only
(regardless of the number of flats/
i.e. requiring residents to meet and greet
apartments, bedsits or bedrooms) and
visitors at the communal door. Doorsets
therefore specifiers are again referred to
shall comply with the physical security
the content of paragraph 21.1 to 21.17
requirements of paragraph 21.1 to 21.17
and 21.19 to 21.22.
and 21.19 to 21.22.
27.8 Communal entrance doorsets in blocks Physical security requirements
serving 4 dwellings or less, over more for communal entrance doorsets
than two floors, are required to have a with an electronic visitor door entry
visitor door entry system and access system serving 10 dwellings or
control system (regardless of the more
42
27.14 Communal entrance doorsets serving particularly heavy communal entrance/
10 dwellings or more, controlled by exit doors have become detached from
visitor door entry systems, can enable the frame, which could have resulted
residents to gain access without in serious injury or worse. Certification
the use of a key and grant entry to to BS 6375 (Parts 1, 2 and 3) provides
visitors by means of an electronic door reassurance that the doorset is fit for
release system. An increased number purpose and safe in use. Specifiers
of dwellings results in doorsets being should be satisfied that the following
used more frequently. Likewise the attributes are addressed:
proximity of the development to a
high crime area can subject doorsets
• Duty level – this is the number of
door operations (opening and closing
to more abuse. Therefore specifiers
actions) that it has been tested to. In
should satisfy the DOCO that the
simple terms the more dwellings that
doorset is fit for its intended purpose
and environment. Certification to PAS are served the higher the duty level
24:2016 or STS 201 may be acceptable should be (BS 6375 Part 2 provides
for some developments, but full third further guidance);
party certification to one of the following • Weather performance - which may be
standards can demonstrate the doorset influenced by the geographical location,
is of a more robust construction and is temperature and climate (BS 6375 Part
able to withstand the day to day use in a 1 provides further guidance);
communal application:
• Wind resistance – also influenced by
• S TS 202 Issue 6:2015 Burglary the location of the building (BS 6375
Rating 2; or Part 1 provides further guidance);
• LPS 1175 Issue 7.2:2014 Security • And relevant sections of BS 6375 Part 3
Rating 2+; or (applicable to the installation).
• LPS 1175 Issue 8:2018 Security
Rating A3+; or Door entry and access control
systems
• LPS 2081 Issue 1.1:2016 Security
Rating B; or 27.16 All communal dwellings (see paragraph
• PAS 24:2016, paragraph 4.4.3 i.e. 27) with 10 flats, apartments, bedsits
or individual bedrooms, or more should
tested to BS EN 1627 Resistance
Class 3 (Note 27.14). have a visitor door entry system and
access control system to enable
Note 27.14: Specifiers are reminded management oversight of the security
that doorsets utilising non-mechanical
of the building i.e. to control access to
magnetic locks fall within the scope of
the building via the management of a
PAS 24:2016 but outside the scope of
recognised electronic key system.
EN 1627. All testing to this standard
utilising a mechanical lock shall be 27.17 Visitor door entry systems that utilise
conducted in accordance with the ‘UK CCTV must comply with the requirements
Police Service (Secured by Design) of paragraph 29.
Interpretation document for BS EN 1627,
BS EN 1628, BS EN 1629 & BS EN Small developments (up to 25 flats/
1630’. This is a requirement within the apartments, bedsits or bedrooms)
UK national forward of BS EN 1627. 27.18 Visitor door entry systems and access
27.15 There have been numerous examples control systems are not normally required
of sub-standard doorsets failing, due to for communal developments with 4
poor general performance, leading to or less flats, apartments, bedsits or
insecure properties. In some cases, bedrooms or less spread over no more
43
than two floors, or where the
accommodation is not intended for use
• Unrestricted egress from the building
in the event of an emergency or power
by the older or disabled people. failure;
It should be noted however, that
regardless of the size of any
• Control equipment to be located in
a secure area within the premises
development where dwellings are covered by the CCTV system and
inclusively designed to provide contained in a lockable steel cabinet to
accessible housing, consideration should LPS 1175 Security Rating 1 or STS 202
be given to disabled and older residents Burglary Rating 1.
who may require additional access
27.21 Developers and installers of visitor
features such as full automation via
door entry systems and access control
remote key fob to enable independent
systems should be aware that UL 293
entry through all doors required to gain
provides reassurance that a system has
access e.g. from the building entrance/
been assessed against a prescribed
exit/car park, through any additional
security test regime.
communal or lift doors required to gain
access to their dwelling entrance. This 27.22 Tradesperson release mechanisms are
may be required due to an inability to not permitted as they have been proven
operate heavy doors and/or reach and to be the cause of anti-social behaviour
operate controls or wall mounted fobs. and unlawful access to communal
developments.
27.19 Developments containing up to and
including 9 flats, apartments, bedsits or 27.23 Specifiers are reminded that the installed
bedrooms spread over more than two electronic release hardware must form
floors (three floors or more including part of the certificated doorset range.
basement level accommodation)
shall comply with the requirements of Developments with more than
paragraph 27.8. 25 flats, apartments, bedsits or
bedrooms
27.20 Smaller developments containing up
to and including 25 flats, apartments, 27.24 Larger developments containing more
bedsits or bedrooms shall have a visitor than 25 flats, apartments, bedsits or
door entry system and access control bedrooms shall have a visitor door entry
system. The technology by which the system and access control system. The
visitor door entry system operates is a technology by which the access control
matter of consumer choice, however it system operates is outlined within UL
should provide the following attributes: 293, however it must provide the following
attributes:
• Access to the building via the use of a • Access to the building via the use of a
security encrypted electronic key (e.g.
security encrypted electronic key (e.g.
fob, card, mobile device, key, etc.);
fob, card, mobile device, key etc.);
• Vandal resistant external door entry • Vandal resistant external door entry
panel with a linked camera;
panel with a linked camera;
• Ability to release the primary entrance • Ability to release the primary entrance
doorset from the dwelling or bedroom doorset from the dwelling or bedroom
(in the case of student accommodation (in the case of student accommodation
or House in Multiple Occupation); or House in Multiple Occupation);
• Live audio and visual communication • Live audio/visual communication
between the occupant and the visitor; between the occupant and the visitor;
• Ability to recover from power failure • Ability to recover from power failure
instantaneously; instantaneously;
44
• Unrestricted egress from the building 27.27 In the event of a power failure door locks
in the event of an emergency or power shall revert to a safe (unlocked) mode
failure; unless there is a fire evacuation policy
in place that requires doors to remain
• Capture (record) images in colour of locked, such as that operated within
people using the door entry panel and
some care homes.
store for those for at least 30 days. If the
visitor door entry system is not capable 27.28 Tradesperson release mechanisms are
of capturing images, then it should be not permitted as they have been proven
linked to a CCTV system or a dedicated to be the cause of anti-social behaviour
CCTV camera should be installed for and unlawful access to communal
this purpose. This information should be developments.
made available to police within 3 days
upon request; Security compartmentation of
developments incorporating 25 or
• All visitor and resident activity on the more flats, apartments, bedsits or
visitor door entry system should be bedrooms
recorded and stored for at least 30
days. This information should be made 27.29 Developments of over 25 flats,
available to police within 3 days upon apartments, bedsits or bedrooms
request. can suffer adversely from anti-social
behaviour due to unrestricted access
• Systems must comply with General to all areas and floors of the building.
Data Protection Regulations (GDPR). SBD therefore seeks to prevent unlawful
27.25 SBD recommends the use of colour free movement throughout the building
monitors to enable the occupier of through the use of an access control
the dwelling or bedroom with the system. How this is achieved is a matter
identification of visitors or to assist the for the specifier, the following two
occupier to accurately describe the methods are acceptable:
colour of clothing to the police of the 1. L
ift and stairwell access controlled
perpetrators of antisocial behaviour or separately:
those otherwise misusing the system.
• To prevent the lift and stairwell
27.26 Specifiers are reminded that the installed providing unrestricted access onto
electronic release hardware must form a residential landing, each resident
part of the certificated doorset range. should be assigned access to their
45
floor only via the use of a security 27.33 It is imperative that the fire service should
encrypted electronic key (e.g. fob, card, have unrestricted access to all floors in
mobile device, key etc.) both on the the event of an emergency so the internal
stairwell/landing door and lift; access control system utilised should
incorporate the following features:
• Access to stairwells from the communal
lobby should be restricted to residents 27.33.1 Where unlawful free internal movement
to reduce the risk of anti-social is restricted via the lift then the fire
behaviour or criminal activities; service must be afforded access via a
‘firefighter’s mode’ or an evacuation lift in
• Unrestricted egress from a landing into ‘evacuation mode’.
the stairwell and from the stairwell to
the communal lobby/emergency fire 27.33.2 If unlawful free internal movement has
exit should be provided at all times. been restricted via an access control
system acting on dedicated external
2. Lift and stairwell access jointly doorsets and any additional doorsets
controlled via an additional secure providing access to individual floors/
doorset: landings then an electronic release must
• An additional secure doorset prevents be incorporated within the system to
access to each landing from both the allow the fire service free access to all
lift and stairwell. Each resident should of the communal areas of the building.
be assigned access to their floor only The electronic release system must be
via the use of a security encrypted weatherproof, easily identifiable and
electronic key (e.g. fob, card, mobile located close to the entrance that Fire
device, key etc.) for this doorset; and Rescue Teams would use in the
event of an emergency. It has been
• Access to stairwells from the agreed between the police and fire and
communal lobby should be restricted rescue services that the most practical
to residents to reduce the risk of anti- means of achieving this aim is to install
social behaviour or criminal activities; a switch within an Access Control Box
• Unrestricted egress from a landing (ACB). The key system for the ACB
into the stairwell and from the stairwell should be of a restricted type acceptable
to the communal lobby/emergency fire to the local fire and rescue service.
exit should be provided at all times. An ACB must be secure for obvious
reasons and therefore shall be tested
27.30 In the event that a lift opens directly into
and certificated to one of the following
an apartment a security protocol must
standards:
be agreed between the occupiers and
the lift maintenance company to ensure • LPS 1175 Issue 7.2:2014 Security
access cannot be gained without the Rating 2; or
proper authority. • LPS 1175 Issue 8:2018 Security Rating
27.31 Alternative methods of creating A3+; or
compartmentation within the building • STS 205 Issue 1:2011 Burglary Rating
may be discussed with the DOCO. 2.
27.32 Whether access at these locations is 27.33.3 The use of an ACB is in addition to the
provided to legitimate visitors as well installation of a Premises Information Box
as residents via additional call points, (PIB), which are recommended by the fire
is a matter for the overall access and rescue service and are referenced
control strategy. It is not the intention of within clauses of BS 9991:2015. The ACB
Secured by Design to restrict legitimate should be clearly marked with a photo-
free flow of residents through the luminescent identification sign in the
building, this will be at the discretion of same way as the PIB. The exact location
the management company concerned. of an ACB should be specified following
46
consultation with the local Fire and 28.4 Only the management body shall be
Rescue Service. permitted to add a device to the system,
however the principal resident(s) shall be
Emergency door release devices permitted to remove a device from the
27.34 Break glass emergency door exit release system.
devices (often green in colour) on 28.3 Remote unlocking (e.g. when operated
communal external doors that provide an from outside the boundary of the
important aid to egress in the event of an residence utilising mobile equipment
emergency have proven to be abused such as smart phones and tablets)
rendering some buildings insecure for should only be permitted when there
long periods of time. SBD recommends is both a live audio and visual feed.
vandal resistant stainless steel self- Systems should not permit users to
resetting emergency exit systems are remotely release the door lock where
installed as an alternative. The installation there is audio only communication, e.g.
and system type must be in full poor signal area, loss of signal, etc.
compliance with the Building Regulations
28.4 If the facility of remote unlocking is
and achieve final ‘sign-off’ by local
abused by a resident, the system shall
Building Control or Approved Inspector.
be capable of restricting their ability to
27.35 If the break glass emergency door unlock a door by way of a land-line in the
release device provides access residence linked to a visual monitor only.
to residential areas as part of the
28.5 If residents do not possess the required
emergency egress route, additional
equipment to use the system, a
security must be provided to restrict
dedicated device should be installed
access to the fire egress route only to
inside the dwelling to give audio and
maintain the security of the building line.
visual communication.
This is also a requirement of Part Q of
the Building Regulations (England and 28.6 Specifiers are reminded that if telephone
Wales). and/or IP based visitor door entry
systems are utilised there should be no
usage charge incurred by the resident as
28 Telephone and Internet a result of a system activation.
Protocol (IP) based visitor 28.7 Specifiers are reminded that if
door entry systems with telephone and/or IP based visitor door
or without remote unlocking entry systems are utilised, they shall
also comply with the requirements of
28.1 To ensure that the viewed image is of paragraph 27.
appropriate quality, systems of this kind
shall be demonstrated to the DOCO on
equipment similar to that used by residents 29 CCTV and Recording
(e.g. TV smart phone or tablet), prior to
receiving Secured by Design accreditation. 29.1 CCTV is not a universal solution to
security problems, it forms part of an
28.2 All systems shall comply with UL293 and overall security plan. It can help deter
the Internet Protocol security shall be crime and criminal behaviour, assist with
tested and certificated to British Standard’s the identification of offenders, promote
Institute Kitemark for the Internet of Things personal safety and provide reassurance
(IoT) Devices, by 1st October 2019. for residents and visitors. Even the
28.3 The system must be capable of catering smallest development will benefit from
for a minimum of 2 and a maximum of 6 the installation of a good quality CCTV
devices being activated as controllers per system, which does not need to be
dwelling. expensive.
47
29.2 Images of people are covered by the Design for residential developments.
General Data Protection Regulation Most CCTV systems are designed for
(GDPR), and so is information about recording images and for the post event
people which is derived from images – for investigation only, in which case nobody
example, vehicle registration numbers. is required to monitor the activities live.
Most uses of CCTV will be covered by the Police recommend that images are stored
Act, regardless of the number of cameras for a minimum of 31 days.
or how sophisticated the equipment is. 29.8 Early discussions with an independent
29.3 Specifiers are reminded that there will CCTV expert and potential installers can
be a requirement for a data controller resolve a number of matters, including:
to ensure compliance with the GDPR. • monitoring and recording requirements;
The data controller must ensure that all
CCTV images that can be used to identify
• activation in association with the intruder
alarm;
individuals are used, stored and disclosed
in line with the GDPR principles. • requirements for observation, facial
recognition/identification and automatic
29.4 It is important that signs are displayed number plate recognition (ANPR);
explaining that CCTV is in operation.
• areas to be monitored and field of view;
29.5 A CCTV system should:
• activities to be monitored;
• have CCTV cameras contained in • the use of recorded images;
vandal resistant housings with the facility
for ceiling or wall mounting; • maintenance of equipment and the
management of recording;
• record images in colour HD quality; • subsequent on-going training of
• not be affected by concentrated white operatives.
light sources directed at the camera,
such as car head lights and street 29.9 Further advice, including the ICO CCTV
Code of Practice is available at:
lighting;
www.ico.org.uk
• ‘on-site’ recording equipment or other 29.10 The system will be fully operational and
hard drive unit will be contained in a
demonstrated to the DOCO upon final
lockable steel cabinet to LPS 1175
inspection, prior to receiving Secured by
Security Rating 1 (A1) or STS 202
Design accreditation.
Burglary Rating 1;
• identify each camera’s location and
record this information along with time 30 CCTV management
and date stamping;
and maintenance protocols
• provide suitable methods of export and
incorporate the required software to view 30.1 The data controller must facilitate the
the exported footage. availability of images at all times to the
29.6 CCTV cameras associated with visitor police upon reasonable request. Contact
door entry systems covering communal details for the data controller must be
entrances and internal lobby areas should clearly displayed in accordance with the
be installed and be capable of providing requirements of the GDPR.
images of persons that are clearly 30.2 An ‘As Installed’ system specification
identifiable on smaller devices such as and schematic, site specific drawing and
smart phones. logbook will be provided to the system
29.7 Ideally, CCTV systems should be controller(s) and available to be viewed at
monitored live 24/7 giving the ability to all times.
react to a situation as it occurs. However, 30.3 It is recommended that the system
this is not a requirement of Secured by receives a minimum of two maintenance
48
inspections per year. Each camera emergency egress from underground
will be cleaned and a test recording car parking areas must meet the
completed and compared with the requirements of both Part B and Part Q
previous recording, to ascertain any of the Building Regulations (England). In
deterioration in quality and performance. practice this provides a dilemma as the
The contractor should issue a certificate performance requirements for the two
of operational safety and security. Building Regulations can be diametrically
opposed to one another and problematic
30.4 The contractor will provide system- if not dealt with appropriately at the
operating manuals to the system design stage. As a result of detailed
controller(s), which will include the discussions with the fire service we have
method of reviewing and archiving agreed the following requirements (see
recorded images and will be available for paragraphs 31.3 to 31.8) as an alternative
use at all times. design solution for just such a scenario.
30.5 The contractor will issue a certificate 31.3 Doorsets allowing emergency egress
to confirm that the CCTV installation is directly from the car park to the street,
compliant with BS 7958: 2015 Closed or any area that allows for the rapid
circuit television (CCTV. Management dispersal of persons from the vicinity of
and operation. Code of practice), and the the building, other than into common
requirements of the GDPR. internal areas, are not required by the
Building Regulations (England and
30.6 The contractor will issue an NSI or SSAIB
Wales) to be secure doorsets. However,
(or equivalent) certificate of compliance SBD requires all such doorsets shall
for the CCTV system. meet the requirements within Section 2a,
30.7 The contractor will issue a certificate to paragraphs 21.1 to 21.17, and 21.19 to
confirm that the systems and installations 21.22.
are in compliance with SBD guidelines. 31.4 Emergency egress from the car park
should be facilitated via the use of a
‘break glass’ unit and all such doors
31 Doorsets providing alternative should be equipped with an audible
access to communal areas warning which should also form part of a
security alarm system.
(other than the primary shared
31.5 Doorsets providing exit from underground
or communal access doorset) car parking facilities (including emergency
including emergency egress egress doorsets) into common or shared
doorsets stairwells which rely on egress via
communal areas of a development are
31.1 Alternative access doorsets, emergency required to meet all relevant Building
egress and fire doorsets that may be Regulations. Due to the fact that
used by residents to access communal emergency egress doorsets from such
parts of the building are also required facilities must also be provided with ‘break
to be ‘secure doorsets’, see Approved glass’ to exit hardware, there is potential
Document Q, Section 1, paragraph 1.1. for such doorsets to be detrimental to the
Doorsets shall meet the requirements security of the building and at odds with
the performance requirements with Part
within paragraphs 21.1 to 21.17, and
Q of the Building Regulations in England
21.19 to 21.22.
and Wales (Performance requirement ‘b’).
Therefore such doorsets shall be isolated
Emergency egress doorsets from
from common or shared stairwells and
underground car parks preferably provide egress directly from
31.2 Doorsets providing access to and the underground car parking area on
49
to the street, or any area that allows for glazing thicknesses may vary between
the rapid dispersal of persons from the manufacturers/suppliers.
vicinity of the building.
31.6 If this is not possible due to the 32 Mail delivery in buildings
design constraints of the building then
emergency egress shall be afforded at the
containing multiple dwellings
earliest possible opportunity and provision or bedrooms
shall be made to restrict access to the
common or shared stairwell beyond the 32.1 There are increasing crime problems
ground floor, or first available floor level. associated with the delivery of post to
Access must also be restricted to any buildings containing multiple dwellings or
other communal area of the building. All bedrooms. Therefore mail delivery that
doorsets affording restricted access into compromises the security of residential
the communal areas of the building, and areas of a multi-occupied building in
all emergency egress doorsets exiting on order to deliver individually to each
to the street, shall meet the requirements residence is not permitted. Facilities
within paragraphs 21.1 to 21.17, and should be provided that enable mail to be
21.19 to 21.22. delivered to safe and secure areas such
as described below.
31.7 Where there is an underground car
parking facility and emergency egress Communal mail delivery
afforded via a route which utilises a
32.2 Communal mail delivery facilities
common or shared stairwell or other
within building entrances serving
communal areas it is required that an
multiple flats or rooms (such as student
access control box (ACB) is installed. This
accommodation) should be designed to
is in addition to a premises information
incorporate the following:
box (PIB) in accordance with BS
9991:2015 to provide the fire service • Located at the primary entrance/exit
the appropriate information about the point of the building within view, within
building. an internal area covered by CCTV
31.8 Access control systems on all doors or located within a secure access
allowing access to communal areas of controlled entrance hall, or externally at
the building shall meet the requirements the front of the building within view of
within paragraph 27 – 28.7 (inclusive). those using the building;
• Be of robust construction;
Glazing in communal entrance
doorsets
• The individual letter boxes shall have
a maximum aperture size of 260mm x
31.9 Where a glazed vision panel is installed 40mm;
it must form part of the manufacturers
certificated doorset range.
• Have anti-fishing properties;
31.10 Specifiers should note that Part Q of • Have fire resistance where considered
the Building Regulations (England and necessary;
Wales) and Building Standards 4.13 • Installed in accordance with the
(Scotland) both reference PAS 24:2012. manufacturers specification.
Therefore the minimum specification for 32.3 Internal communal mail delivery facilities
any glazing within shared or communal serving multiple flats or rooms (such
entrance doorsets is BS EN 356:2000 as student accommodation) should be
Class P1A (minimum). It should be designed to incorporate the following:
noted that PAS 24:2016 makes exactly
the same requirement. NB This is a • L ocated in view, within a secure area
security performance criteria rather than at the primary building entrance point/
a glazing thickness specification, so exit point;
50
acceptable if this is dimmed during
• Be of robust construction; hours of low occupation to save energy.
• The individual letter boxes shall have This will normally include the communal
a maximum aperture size of 260mm x entrance hall, lobbies, landings, corridors
40mm; and stairwells and underground garaging
• Have anti-fishing properties; facilities and all entrance/exit points. To
reduce energy consumption, lighting
• Have fire resistance where considered systems that reduce light levels during
necessary; quieter periods may be utilised. Further
• Installed in accordance with the information is available at
manufacturers specification. www.securedbydesign.com
• Building access strategy to account
for residents who will rely on others to
collect their mail.
34 Loft hatches in communal
areas
32.4 Letter boxes certificated to Door
& Hardware Federation Technical 34.1 Loft hatches located in communal areas,
Specification 009 (TS 009) offer such as over landings in blocks of flats,
reassurance that all of the above must be locked to prevent access into a
attributes have been met. In high crime dwelling via the loft space. This may still
areas TS 009 provides the safest means be required even where the loft space
by which mail can be delivered whilst has been compartmented to prevent
eliminating the risks associated with the spread of fire and smoke (products
letter mail delivery i.e. arson, ‘fishing’ for meeting the requirements of published
personal mail. fire safety standards are available).
There are currently no ‘hinged’ or ‘lift
out’ loft hatches being manufactured
33 Lighting for buildings to recognised security standards, but
containing multiple dwellings where padlocks, hasps and staples
are used to secure the hatch the
products must be certificated to BS EN
External lighting 12320:2012, Sold Secure ‘Silver’ or LPS
33.1 Lighting is required to each elevation 1654 Issue 1.1:2014 Security Rating
that contains a doorset where the public, 1 and fitted in accordance with the
visitors or occupants of the building are manufacturer’s instructions.
expected to use (Note 33.1). 34.2 The responsibility for the specification
and location of fire rated security
Note 33.1: Secured by Design has
products lies with the developer or the
not specified PIR activated security
developer’s agent.
lighting for a number of years following
advice from the ILP and police concern
regarding the increase in the fear of
crime (particularly amongst the elderly)
due to repeated PIR lamp activations.
Research has proven that a constant
level of illumination is more effective at
controlling the night environment.
Internal lighting
33.2 24 hour lighting (switched using a
photoelectric cell) to communal parts
of blocks of flats will be required. It is
51
SECTION 2b
35 Introduction with compliance to Section 1, and where
applicable the relevant parts of Section
35.1 This section provides technical guidance 3, a Secured by Design Silver Award
for bespoke new homes and the may also be achieved.
refurbishment of existing homes. It is 35.4 Major refurbishment schemes should
expected, in order to gain SBD approval, meet the requirements within Section 2a.
that new homes and existing homes with
standard door and window products will 35.5 Section 2b of this guidance document is
follow the requirements within Section further separated into two areas:
2a, where possible. However, Approved 35.5.1 Houses, bungalows, flats, apartments
Document Q (English and Wales or maisonettes accessed via a private
Building Regulations) and Scottish dedicated entrance doorset;
Building Regulation 4.13 both allow an
alternative route to compliance, which 35.5.2 Buildings containing multiple dwellings
utilises a door or window specification or bedrooms accessed from a semi-
incorporating components that have private area and served by a shared or
been tested to published security communal entrance doorset.
standards and therefore SBD has
responded by providing additional
guidance in these areas. 36 New ‘bespoke’ houses,
35.2 Approved Document Q, Appendix B, bungalows, flats, apartments
does not provide a definition of what or maisonettes accessed
is a ‘bespoke’ doorset or window. For
the purposes of Secured by Design it is
via a private dedicated
considered beneficial for all parties, and entrance doorset
in the interests of clarity, to provide a
definition. Secured by Design therefore 36.1 The term “doorset” refers to a door,
has defined a bespoke doorset or frame, locks, fittings and glazing as one
window to be: combined unit.
A single or small number of doorsets 36.2 All new bespoke doorsets allowing
or windows installed within a direct access into to the home e.g. front
development (normally no more than and rear doors, interconnecting garage
4 homes) of unique design with non- doorsets, French doors, Bi-fold or sliding
standard features which preclude patio doorsets, dedicated private flat
the use of conventional enhanced or apartment entrance doorsets, easily
security door and window products. accessible balcony doorsets (Note 36.2)
Doorsets or windows installed within etc., are required to be secure doorsets
buildings of specific architectural within the UK Building Regulations (see
value, constrained by listed building paragraph 1.1).
or other conservation status may also
be considered to be bespoke. Note 36.2: Easily accessible is defined
within Approved Document Q Appendix
35.3 Where there is a client led requirement
A as:
for Secured by Design accreditation,
compliance with this section alone will • A window or doorset, any part of which
lead to the issue of a Secured by Design is within 2 metres vertically of an
Bronze Award, however when combined accessible level surface such as
52
a
ground or basement level, or an 36.5.1 Material – doorsets and windows should
access balcony, or be manufactured from solid or laminated
timber with a minimum density of
• A window within 2 metres vertically of a 600kg/m³.
flat roof or sloping roof (with a pitch of
less than 30˚) that is within 3.5 metres 36.5.2 Dimensions (doorsets):
of ground level. • Door rails, stiles and muntins should
36.3 Where there is a requirement for a be at least 44mm thick. After rebating,
doorset to be both fire and security rated, frame components should retain at
e.g. flat or apartment entrance doorsets, least 32mm of timber;
interconnecting garage doorsets • Any panel within the doorset should be
and some doorsets aiding security at least 15mm thick. The panel should
compartmentation, it is the responsibility be securely held in place. Beading
of the developer or the developer’s agent should be mechanically fixed and glued
to ensure compliance with all applicable in position;
Building Regulations. • The smaller dimension of each panel,
which can be either the width or height
Door and window materials of the panel, should be 230mm or less.
36.4 All bespoke window and doorsets 36.5.3 Dimensions (windows):
constructed from materials commonly
utilised for such purposes such as timber,
• Casement window frame components
(head, sill, jamb, transom & mullion)
PVCu, aluminium, steel and composite
should be a minimum of 67mm deep
shall meet the minimum material specific
and 56 mm wide, rebated and moulded
requirements as follows:
to retain a minimum section of 25mm;
Timber products • Casement and sash components (stiles
and rails) should be a minimum of
36.5 Approved Document Q of the
56mm deep, rebated and moulded to
Building Regulations sets out specific
retain a minimum section of 25mm.
requirements for the material (Appendix
B, clause B.2) and dimensions (Appendix 36.5.4 Maximum length and height dimensions
B, clause B.3, B.4 & B.5) for bespoke by window type:
timber doorsets. Secured by Design • Casement Windows - maximum mullion
supports these requirements for both length 1350mm, maximum transom
doors and windows, for clarity these are: length 1200mm;
53
• Side hung casement (hinged and fully Aluminium products
reversible) open out - 700mm wide by
36.11 All windows and doorsets should be
1350mm high; constructed from aluminium profile
• Top hung casement (hinged and fully fabricated from designated alloys 6060
reversible) - 1200mm wide by 1200mm or 6063 in tempers T5 or T6 conforming
high; to BS EN 12020-2:2016 or equivalent
standard.
• Tilt and turn casement, open in - 36.12 Aluminium profiles used in the
900mm wide by 1350mm high;
construction of the frames excluding
• Vertical sliding sash - maximum mullion glazing beads, nibs, interlocks and similar
length 1500mm, maximum transom features shall be not less than
length 900mm, maximum sash size 1.2 mm thick.
750mm high by 900mm wide. 36.13 Bespoke aluminium products e.g.
36.6 Further guidance for the construction those falling outside the scope of PAS
of good quality timber windows and 24:2016, would benefit from being
doorsets can be sought from BS constructed from a profile that has
644:2012 ‘Timber windows and doorsets. already been proven by test to meet the
Fully finished factory-assembled security requirements of PAS 24:2016
windows and doorsets of various types. in other window styles within the profile
manufacturers or fabricators range.
Specification.’
36.14 Further guidance for the construction of
PVCu products good quality bespoke aluminium windows
and doorsets can be sought from BS
36.7 All windows and doorsets should be 4873:2016 ‘Aluminium alloy windows and
constructed from profile meeting the doorsets. Specification.’
requirements of BS EN 12608-1:2016
Unplasticized polyvinylchloride (PVC-U) Composite products
profiles for the fabrication of windows and
36.15 The Association of Composite Door
doors. Classification, requirements and
Manufacturers has advised SBD that it
test methods.
is unwise to produce a specification for
36.8 Bespoke PVCu products e.g. those falling a ‘bespoke’ application. This is because
outside the scope of PAS 24:2016, would of the myriad of differing materials used
benefit from being constructed from a and indeed the numerous combinations
profile that has already been proven by of composite products found in doorset
test to meet the security requirements products in more recent times. Therefore
of PAS 24:2016 in other window styles it is not possible to create a bespoke
within the profile manufacturers or composite doorset that complies with
fabricators range. Section 2b of this guide.
36.16 Although the material standard, BS
36.9 All window and door profiles should
8529:2017 ‘Composite doorsets.
incorporate reinforcement to cater for the
Domestic external doorsets. Specification’
secure fixing of hardware and to provide
was developed for composite doorset
additional strength to the profile. products, it may be used to provide
36.10 Further guidance for the construction of further guidance for the construction of
good quality bespoke PVCu windows good quality bespoke composite window
and doorsets can be sought from BS that could therefore be acceptable within
7412:2007 ‘Specification for windows Section 2b of this guide.
and doorsets made from unplasticized
polyvinyl chloride (PVC-U) extruded Steel products
hollow profiles.’ 36.17 Guidance for the construction of
54
good quality bespoke steel windows 36.20 The above mortice locks should be
and doorsets can be sought from BS supplemented with a surface mounted
6510:2010 ‘Steel-framed windows and rim lock conforming to the same
glazed doors. Specification’ standard, fitted one third of the way down
the lock stile.
Doorset hardware and locking 36.21 Non-primary doorsets (back or garage
systems interconnecting doorsets) may be
36.18 The primary entrance doorset should be fitted with a multi-point locking system
fitted with a multipoint locking system conforming to the standards in paragraph
that meets the requirements of: 36.18 above, alternatively single point
locks conforming to the standards in
• PAS 3621:2011 (key locking both paragraph 36.19 above are acceptable
sides); or
when supplemented with two mortised
• PAS 8621:2011 (non-key locking on the bolts with a minimum projection of 20mm
internal face); or (located a minimum of 100mm from
the top and bottom corners of the door,
• PAS 10621:2011 (non-key locking on avoiding any door construction joints).
the internal face – with an external
locking override facility). 36.22 All bespoke doorsets shall be installed
with hinge bolts or specialist interlocking
36.19 Alternative lock configuration for a
hinges. Hinges accessible from outside
primary dwelling doorsets (usually
the building should not have removable
the front doorset) can be achieved by
pins.
the installation of a mortice or surface
mounted lock conforming to the below 36.23 To ensure that the end user of the door
standards and fitted one third of the way understands how to operate the locking
up the lock stile: system, clear operating instructions must
be attached to the inner face of the door
• BS 3621:2017 (key locking both sides); (Note 36.23). The instructions should be
or
easily removable by the end user.
• BS 8621:2017 (non-key locking on the Note 36.23: The purpose of providing
internal face); or
the end user with operating instructions
• BS 10621:2017 (non-key locking on the is to reduce the number of burglaries
internal door face, but with an external through otherwise secure doorsets,
locking override facility). because the full locking system has
55
not been engaged. This is particularly installed on the doorset to which a caller
problematic with split spindle multi-point can be expected, normally the front door
locking systems, where, for example, (see Approved Document Q, Section 1:
the occupier goes to bed at night without Doors, paragraph 1.4). All such devices
engaging the locks in the mistaken should be suitable for the door material
belief that leaving the door closed only to which they are fitted and be installed
on the latch (live bolt) is sufficient. The in accordance with the manufacturer’s
instructions should point out that the recommendations.
doorset is not totally secure unless the 36.26 A door viewer meeting the requirements
locking system is fully engaged. The with the Door & Hardware Federation
method of attachment of these operating Technical Specification 002 (DHF TS
instructions and the medium used to 002) standard must be fitted between
carry them is for the door manufacturer 1200mm and 1500mm from the bottom of
to decide but are not intended to be the door, this is not required if the doorset
permanent. is installed with clear glazing or if there
is a side panel with clear glazing (see
Glazing in and adjacent to doorsets Approved Document Q, Section 1: Doors,
36.24 Any glazing within bespoke doorsets, paragraph 1.4).
including glazed panels/side lights
adjacent to doors installed within an Doorset Installation
integral door frame and windows adjacent 36.27 Door frames must be securely fixed to
to doorsets (within 400mm), must the building fabric in accordance with the
incorporate one pane of laminated glass manufacturer’s specifications.
meeting, or exceeding, the requirements
of BS EN 356:2000 class P1A (Note 36.28 Due to the dynamic forces experienced
36.24). Specifiers are reminded that this when doorsets are opened and closed,
is also a requirement within ADQ, Annex frame installation packers should be
B, paragraph B.11. used. This will limit outer frame distortion
during installation and use, ensuring that
Note 36.24: There is no specific the frame remains centralised, level and
requirement to install laminated glazing square and allows for thermal movement
on the inner or outer face of a double of the frame.
glazed unit. However specifiers may
wish to take into consideration the fact 36.29 Doorsets that are hidden from public
that toughened glass is usually more view, typically side or back doors, should
resistant to accidental damage by blunt not be recessed more than 600mm. This
objects such as a football and therefore requirement is not applicable to doorsets
may be best placed on the external that are located within public view (Note
face of the double glazed unit. It is 36.29). However, no doorset should be
recognised however that there are many recessed by more than 1000mm.
other factors that may also need to be Note 36.29: For the purposes of this
considered such as thermal efficiency, guidance document a doorset is
aesthetics and the requirement for considered to be within ‘public view’ when
privacy or obscured glazing, which will it can be seen from the street.
influence the specifier’s decision.
Internal lighting
49.2 24 hour lighting (switched using a
photoelectric cell) to communal parts
of blocks of flats will be required. It is
acceptable if this is dimmed during
hours of low occupation to save energy.
This will normally include the communal
entrance hall, lobbies, landings,
corridors and stairwells and underground
garaging facilities and all entrance/exit
points. To reduce energy consumption,
lighting systems that reduce light levels
during quieter periods may be utilised.
Further information is available at: www.
securedbydesign.com
51.4 Developers wishing to apply for the SBD Note 53.1a: There is no specific
Gold Award shall adhere to Sections 1 requirement to install laminated glazing
and 2 in full together with the relevant on the inner or outer face of a double
features contained within this section. glazed unit. However specifiers may
wish to take into consideration the fact
that toughened glass is usually more
resistant to accidental damage by blunt
objects such as a football and therefore
may be best placed on the external
65
face of the double glazed unit. It is that compliance with a similar alternative
recognised however that there are many standard from another supplier or
other factors that may also need to be country has been achieved this may be
considered such as thermal efficiency, accepted as an alternative to the above
aesthetics and the requirement for standards.
privacy or obscured glazing, which will 54.3 Specifiers are reminded of the
influence the specifier’s decision. requirements within the English Building
Note 53.1b: Easily accessible is defined Regulations (Part Q), see Section 2a,
within Approved Document Q Appendix paragraph 20.1.
A as: 54.4 The DOCO must be supplied with proof
• A window or doorset, any part of of certification including the technical
which is within 2 metres vertically of schedule (sometimes referred to as
an accessible level surface such as ‘Scope of Certification’) prior to the SBD
a ground or basement level, or an certificate being awarded, unless the
access balcony; or supplier is a member of the Secured
by Design Licensing Scheme and the
• A window within 2 metres vertically of a doorset can be identified on the SBD
flat roof or sloping roof (with a pitch of
website.
less than 30˚) that is within 3.5 metres
of ground level. 54.5 Alternatively a vehicle access door
that is not certificated to one of the
above standards, and not subject to
54 External garage doorsets the requirements within the English
and Welsh Building Regulations (Part
54.1 If a development incorporates garages Q), may be deemed satisfactory if an
and the developer wishes to gain the external ‘garage door defender’ type
full SBD Gold Award then the security of security product is also fitted. Such
both the dwelling and the garage must products must be certificated to Sold
be considered. If a garage is not secured Secure Bronze level or above.
as part of the security of the dwelling,
or it is detached from the dwelling, then
external pedestrian access doors must 55 Car parking
meet the same physical, locking and
fixing specification, as ‘Dwelling entrance Communal car parking areas
doorsets’ (Section 2a paragraphs 21.1 to 55.1 Where communal car parking areas
21.21). are necessary they should be in small
54.2 Vehicle access doorsets shall be groups, close and adjacent to homes
certificated to one of the following and must be within view of the active
standards (Note 54.2): rooms within these homes (Note 55.1).
It may be necessary to provide additional
• LPS 1175: Issue 7.2:2014 Security windows to facilitate overlooking of the
Rating 1+ (or above); or
parking facility.
• LPS 1175 Issue 8:2018 A1 Security Note 55.1: The word ‘active’ in this sense
Rating 1+/A1+ (or above); or means rooms in building elevations
• STS 202, Issue 7:2016 Burglary Rating from which there is direct and regular
1+ (or above); or visual connection between the room and
the street or parking court. Such visual
• LPS 2081 Issue 1:2015 Security connection can be expected from rooms
Rating A. such as kitchens and living rooms, but
Note 54.2: Where a manufacturer has not from more private rooms, such as
demonstrated, to the satisfaction of SBD, bedrooms and bathrooms.
66
55.2 Lighting must be at the levels
recommended by BS 5489-1:2013.
• STS 202 Issue 7:2016 Burglary Rating
1; or
The DOCO shall be provided with a
declaration of conformity to BS 5489- • LPS 2081 Issue 1.1:2016 Security
1:2013 by a ‘competent’ independent Rating A.
designer. Competency shall be 55.3.3 Automated gates supplied and installed
demonstrated by achievement to at must meet the relevant statutory
least ILP competency level 3 or 4, i.e. safety standards and be CE marked
the designer will be a member of the ILP accordingly. Specifiers may wish
(MILP) and either IEng or CEng qualified to satisfy themselves that installers
to be deemed competent to be able to of powered gates are appropriately
design under Construction Design and qualified, trained and follow recognised
Maintenance (CDM) Regulations. industry guidance. The following
Further information is available at: organisations provide guidance and
www.securedbydesign.com training for installers:
Dwelling lighting
59.4 Lighting is required to illuminate all Revisions to text
elevations containing a doorset, car
parking and garage areas and footpaths Paragraph 5 of the 27.13
leading to dwellings and blocks of flats. Preface 27.14
Bollard lighting is not appropriate as it 10.6.7
does not project sufficient light at the 27.20
right height making it difficult to recognise 10.7 27.28
facial features and as a result causes an 13.2 27.31
increase in the fear of crime.
13.3 27.33.2
59.5 Secured by Design encourages,
wherever possible, the use of the most 16.15 29.5
environmentally friendly light sources. 21.3 + Notes 21.3a - 34.1
Moreover the Institute of Lighting 21.3e
Professionals (ILP) currently favours 36.3
the use of good quality LED lighting and 21.5 50.1
other energy effective light sources and 21.10 54.2
advises against the use of fluorescent
lighting which is environmentally 22.2 + Note 22.2d 55.3.2
unsustainable for a variety of reasons 22.12 56.1
(Note 59.5). Further information is
available at: www.securedbydesign.com 22.13 56.2
HDG0119