G2: Design Group 2 B1: column ACI 318M-05 Column M17, M18, M19, M20, M21, M22, M23
M24, M25, M26, M27, M28, M29, M30
M31, M32, M33, M34, M35, M36, M37
M38, M39, M40, M41, M42, M43, M44
M45, M46, M47, M48
Cover = 50 mm
Axial N = 4426.38 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Minor axis:
OK
Cover = 50 mm
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Member 18 - Detailed ACI Shear Reinforcement
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 9.58 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 6573.98 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
OK
Cover = 50 mm
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Axial N = 3190.00 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Design torsion moment, Tu = 2.09 kNm
Minor axis:
OK
Cover = 50 mm
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Axial N = 4793.22 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
Major axis:
Minor axis:
OK
Member 23 - Detailed ACI Design Requirements
Cover = 50 mm
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Axial N = 5082.32 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Axial N = 4773.03 kN
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 2259.82 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Member 26 - Detailed ACI Main Reinforcement
Axial N = 3332.67 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
Major axis:
Minor axis:
OK
Member 27 - Detailed ACI Design Requirements
Cover = 50 mm
Axial N = 3605.34 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 3383.59 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
Biaxial Interaction Equation = [(Muz/Mnz)]a + [(Muy/Mny)]a1.0
OK
Major axis:
OK
Cover = 50 mm
Axial N = 1114.24 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 1715.84 kN
Major M, end 1, = -131.70 kNm
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 1879.33 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 1782.79 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 3179.90 kN
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 6109.07 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Member 35 - Detailed ACI Main Reinforcement
Axial N = 7690.77 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
Major axis:
Minor axis:
OK
Member 36 - Detailed ACI Design Requirements
Cover = 50 mm
Axial N = 5928.68 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Axial N = 2257.28 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Axial N = 4317.88 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Member 39 - Detailed ACI Main Reinforcement
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Axial N = 5582.15 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
Cover = 50 mm
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
NOTE:- Length < 3*smaller dimension. Consider designing this member as a wall. 2.2
Axial N = 21.79 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 1654.38 kN
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 2932.13 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Member 43 - Detailed ACI Main Reinforcement
Axial N = 3882.04 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
Major axis:
Minor axis:
OK
Member 44 - Detailed ACI Design Requirements
Cover = 50 mm
Axial N = 19.04 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 839.19 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
Biaxial Interaction Equation = [(Muz/Mnz)]a + [(Muy/Mny)]a1.0
OK
Major axis:
OK
Cover = 50 mm
Axial N = 9.68 kN
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 1958.70 kN
Major M, end 1, = 142.97 kNm
Major Axis Capacity Major Axis Moment OK for moment resistance
Minor Axis Capacity Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK
Cover = 50 mm
Axial N = 5.37 kN
Major Axis Capacity ³ Major Axis Moment OK for moment resistance
Minor Axis Capacity ³ Minor Axis Moment OK for moment resistance
OK
Major axis:
Minor axis:
OK