You are on page 1of 7

MULTICOR® H450, H800, H1000, H1250

Coriolis mass flow meter


 Continuous mass flow metering according
to the Coriolis principle

 Non-sensitive, highly accurate principle


of measuring

 Fast measured value recording and


high control quality

 Compact construction

 Economical, simple integration

 Dustproof housing
3
 Feedrate up to 1250 m /h

Application
The flanged inlet connections for attaching to the feed pipe
The MULTICOR H Coriolis mass flow meter is a closed provided by customer is fitted with a Jacob pipe connection,
measuring system for continuous totalized amount of smooth pipe ends and flexible connection.
material and feed rate acquisition. The MULTICOR H
measuring device is suitable for: The discharge cone is fitted with a flexible connection for
connecting to the conveyor line provided by customer.
 Throughput and consumption measurement
 Balancing The weighing module makes it possible to easily take on
 Batching jobs at bulk solid temperatures up to 90 °C. For high
From good to slightly sluggish bulk solids. temperatures up to 120 °C, the device is fitted with a cooling
In combination with a controllable prefeeder (e.g. valve, mill fan that is automatically activated as required.
or helix with center rod), the measuring device can also be
Function
used as a feed system.
The MULTICOR H type series offers solutions for many In MULTICOR H measuring devices, the principle of Coriolis
applications: force measurement is used to determine the mass flow rate.
The bulk solids flow being measured hits a measuring wheel
 MULTICOR H
in the device that is rotating at a constant speed.
Gravity feed in operations
The bulk solids are caught by the blades of the measuring
Construction wheel and accelerated to the circumferential speed of the
A MULTICOR H Coriolis mass flow comprises: measuring wheel.

 Mild steel, painted dust-proof hopper


 Measuring rotor with hollow fixed blades
 Weighing module with wireless data transmissions
 Junction box
 AC geared motor (three-phase current)

BV-D2317 GB
A torque is required for the acceleration, which properties of the bulk solids, such as grain spectrum,
directly corresponds to the feedrate. The torque is flow behaviour, humidity and temperature.
measured with a measuring module integrated
The force of the bulk solids on the measuring wheel
directly into the drive line and is converted into a
and changes in the flow speed in the measuring
electrical signal. The data transfer is inductive. The
device do not affect the measuring signal.
measurement is independent of mechanical

Dimensions

MULTICOR® H450
*** recommended space to performe maintenance
Height of fall over inlet: max. 1,5m 1500 *** 1500 ***

Da: ⌀ 402
Flexible joint by others
55
15 0

[mm]
20 0

⌀414
(System Jakob DN400)

***
⌀10 00
100 50
218

13 80
6 10


ø
Ø
(Y)

***
⌀ 508

⌀800
365

by others

559 576 ⌀ 900

Rotation direction measuring wheel (Y)

0
27
⌀1

Cooling fan (optional)

(Y)
47,50°
view downside
Section inspection cover (Y): Connecting cooling air G2-1/2"
3
air requirement: 190...230Nm /h
⌀ 870 / 0,04...0,06bar T(air) max. 40°C

⌀1250
BV-D2317 GB

2/7
MULTICOR® H800
*** recommended space to performe maintenance
Height of fall over inlet: max. 1,5m
1500 *** 1500 ***
Da: ⌀452
Flexible joint by others

55
150

[mm]

200
⌀464 (System Jakob DN450)

50

** *
1000
100

1380
218
6 10


ø
Ø

⌀508

***
365

800
by others

559 576 ⌀900

(Y)
Rotation direction measuring wheel

0
27
⌀1

Cooling fan (optional)

(Y)
47,50° view downside
(Y): connecting cooling air G2-1/2"
Section inspection cover air requirement:190..230Nm3/h
/ 0,04..0,06bar T(air) max. 40°C
⌀870
⌀1250
BV-D2317 GB

3/7
MULTICOR® H1000
*** recommended space to performe maintenance
Height of fall over inlet: max. 1,5m 1500 *** 1500 ***

Da: ⌀502
by others
[mm] Flexible joint

55
⌀514

200

1380
50
(System Jakob DN500)

***
1000
100
218


ø
Ø 610

***
365

⌀508

800
by others

559 576 ⌀900


Rotation direction measuring wheel (Y)

0
27
⌀1

Cooling fan (optional)

(Y)
47 ,50° view downside
Section inspection cover (Y): connecting cooling air G2-1/2"
air requirement:190..230Nm3/h
⌀870 / 0,04..0,06bar T(air) max. 40°C

⌀1250
BV-D2317 GB

4/7
MULTICOR® H1250
*** recommended space to performe maintenance
Height of fall over inlet: max. 1,5m 1500 *** 1500 ***

Da: ⌀562 by others


[mm] Flexible joint

55
200

50

1000** *
1 00


ø
Ø
690

800* **
⌀564
318

by others

559 576 ⌀900


Rotation direction measuring wheel
(Y)
0
27
⌀1

Cooling fan (optional)

(Y)
47 ,50° (Y): connecting cooling air G2-1/2" view downside
air requirement:190..230Nm3/h
Section inspection cover / 0,04..0,06bar T(air) max. 40°C

⌀870
⌀1250
BV-D2317 GB

5/7
Technical Data
Type series H450 H800 H1000 H1250

15 t/h … 150 t/h or


Feedrate 30 t/h … 300 t/h or 60 t/h … 600 t/h 75 t/h … 750 t/h 90 t/h … 900 t/h
40 t/h … 400 t/h
Throughput volumes max. 450 m³/h 800 m³/h 1000 m³/h 1250 m³/h
Accuracy rated to actual
from ±0.5 % (depending on installation configuration)
feed rate
Adjustment range 1 : 10
Operating Pressure -25 mbar … +25 mbar
Ø402 mm Ø452 mm Ø502 mm Ø562 mm
(Connection cone grip (Connection cone grip (Connection cone grip (Connection cone grip
Inlet dimensions
JACOB pipe, JACOB pipe, JACOB pipe, JACOB pipe,
rated width 400) rated width 450) rated width 500) rated width 560)
Outlet connecting Ø508 mm Ø564 mm
Ø508 mm Ø508 mm
dimensions
Weight 850 kg 900 kg 950 kg 1050 kg
Permissible Ambient
-30 °C ... +40 °C
Temperature
Max. bulk solids
temperature without cooling +90 °C
air supply
Max. bulk solids
temperature with cooling air
+120 °C
supply
(Tk max. 40 °C)
Material bulk density min. density 0.3 t/m³
Grain size max.
30/25 mm 25/25 mm
(without/with screen)
Moisture max. 1 %
Flow properties free flowing to slightly sluggish, also flushing, non-sticky
Material property of product Hopper: Painted mild steel
contact parts Measuring wheel: 1.4404/AISI 316 LN/1.4571

Accuracy Additional requirements Order Data


The accuracy stated refers to the If you also have specific requirements, Apart from the order numbers, in order to
actual feed rate in each case in the such as: process your request quickly and smoothly
range of 10 % … 100 % of the nominal we require the following order data:
 larger feedrate ranges
feedrate under the following
Materiald data
conditions:  Direct feeding into pneumatic
conveyor lines Bulk density .................... [t/m³]
Assembly and commissioning
corresponding to our assembly and  Use as feed system Bulk solids ...................
commissioning instructions.
Please contact us directly. Bulk solids temperature .................... [°C]
Because of the Coriolis measuring
principle, the accuracy is not affected
by variable material properties of the Feedrate range
bulk solids (flow behavior, moisture,
From .......................................... [t/h]
temperature, grain size).
To .......................................... [t/h]
BV-D2317 GB

6/7
Options

Prefeeder for MULTICOR H

Measuring wheel with non-stick coating

Measuring wheel with wear protection

Cooling air unit for high bulk solids temperatures

Variants

MULTICOR H450 Coriolis mass flow meter for 15 … 150 t/h with 50/60 Hz drive

MULTICOR H450 Coriolis mass flow meter for 30 … 300 t/h with 50/60 Hz drive

MULTICOR H450 Coriolis mass flow meter for 40 … 400 t/h with 50/60 Hz drive

MULTICOR H800 Coriolis mass flow meter for 60 … 600 t/h with 50/60 Hz drive

MULTICOR H1000 Coriolis mass flow meter for 75 … 750 t/h with 50/60 Hz drive

MULTICOR H1250 Coriolis mass flow meter for 90 … 900 t/h with 50/60 Hz drive

BV-D2317 GB

All information is given without obligation. All specifications are subject to change. © by Schenck Process Europe GmbH, 2018-02-13 7/7

You might also like